HomeMy WebLinkAboutEnergy (EPL) Display Card-zeas- 0/,��
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
.Florida Department of Business and Professional Regulation - Residential Performance Wow2010
Project Name: Lot 32 Block Waterstone 1720 BGL
Builder Name: ADAMS HOMES
ermitting Departmen
St. Lucie Count
Street: 8704 Merano Avenue
Permit Office:
y
City, State, Zip: Fort Pierce, FL, 34951
Permit Number:
Owner:
Jurisdiction: 661000
Design Location: FL, ST_LUCIE_CO_INTL
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (1665.3 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=4.1 1371.10 ft2
b. Frame - Wood, Adjacent
R=13.0 294.17 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 3
d. N/A
R= ft2
10. Ceiling Types (1743.0 sqft.)
Insulation Area
5. Is this a worst case? No
a. Under Attic (Vented)
R=30.0 1720.00 ft2
6. Conditioned floor area above grade (ft2) 1720
b. Knee Wall (Vented)
R=19.0 23.00 ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
11. Ducts
R ft2
7. Windows(183.7 sqft.) Description Area
a. Sup: Attic, Ret: Main, AH: Main
6 344
a. U-Factor: Dbl, U=0.33 152.99 ft2
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.55 20.00 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.70
a. Central Unit
28.4 SEER:15.00
c. U-Factor: Dbl, U=0.33 10.67 ft2
SHGC: SHGC=0.31
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Heat Pump
28.2 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 4.890 ft.
Area Weighted Average SHGC: 0.286
14. Hot water systems
a. Electric
Cap: 40 gallons.
8. Floor Types (1720.0 sqft.) Insulation Area
EF: 0.940
a. Slab -On -Grade Edge Insulation R=0.0 1720.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
Pstat
Glass/Floor Area: 0.107 Total Proposed Modified Loads: 54.76
PASS
Total Baseline Loads: 56.68
I hereby certify that the plans and specifications covered by
Review of the plans and
THEST,�p.
this calculation are in compliance w' lorida Ener
specifications covered by this
Code.
calculation indicates compliance
y`a i/�� ' - '
with the Florida Energy Code.
PREPARED BY:
Before construction is completed
DATE: 04-21-2020 Winn Keomany
this building will be inspected for
compliance with Section 553.908
0 ;d
I hereby certify that this buildin esigned, is i ompliance
Florida Statutes.
✓ �� .
with the Florida Energy-Ge
OWNER/AGENT:
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclos r a lle as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R4 ..1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
4/21/2020 11:29 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
Building Type:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
Lot 32 Block Waterstone 172 Bedrooms: 3
User Conditioned Area: 1720
Total Stories: 1
1 Worst Case: No
ADAMS HOMES Rotate Angle: 0
Cross Ventilation: No
661000 Whole House Fan: No
Single-family
New (From Plans)
Address Type: Lot Information
Lot # 32-1
Block/Subdivision: Waterstone
PlatBook:
Street: 8104 Merano Avenue
County: St. Lucie
City, State, Zip: Fort Pierce ,
FL, 34951
CLIMATE
V Design Location
Design Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90
70 75 299 58 Medium
BLOCKS
Number
Name
Area Volume
1
Block1
1720 15480
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms InfilID Finished Cooled Heated
1
Main
1720 15480 Yes 4
3 1 Yes Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 171.5 ft 0
1720 ft2 ___- 0.26 0 0.74
ROOF
V #
Type
Roof Gable Roof
Materials Area Area Color
Rad Solar SA Emitt Emitt Deck Pitch
Barr Absor. Tested Tested Insul. (deg)
1
Gable or Shed Composition shingles 1924 ft2 430 ft2 Medium
N 0.85 N 0.85 No 0 26.6
ATTIC
V #
Type
Ventilation Vent Ratio (1 in)
Area RBS IRCC
1
Full attic
Vented 300 1720 ft2 N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
2
3
Knee Wall (Vented)
Knee Wall (Vented)
Under Attic (Vented)
Main 19 Batt
Main 19 Batt
Main 30 Blown
5 ft2 0.11 Wood
18 ft2 0.11 Wood
1720 ft2 0.11 Wood
4/21/2020 11:29 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST RFPnRT
WALLS
Adjacent
Space
Cavity Width
Height
Sheathing Framing Solar Below
_ 1 W
Exterior
Concrete Block - Int Insul
Main
4.1 32
4
8 5
272.1 ft2
0
0 0.6
0
2 W
Exterior
Concrete Block - Int Insul
Main
4.1 4
5
9 0
39.8 ft2
0
0 0.6
0
3 W
Exterior
Concrete Block - Int Insul
Main
4.1 11
0
8 0
88.0 ft2
0
0 0.6
0
.4 S
Exterior
Concrete Block - Int Insul
Main
4.1 5
9
9 0
51.8 ft2
0
0 0.6
0
5 S
Exterior
Concrete Block - Int Insul
Main
4.1 12
0
8 0
96.0 ft2
0
0 0.6
0
_ 6 E
Exterior
Concrete Block - Int Insul
Main
4.1 19
9
8 9
172.8 ft2
0
0 0.6
0
7 E
Exterior
Concrete Block - Int Insul
Main
4.1 26
1
9 0
234.8 ft2
0
0 0.6
0
8 E
Exterior
Concrete Block - Int Insul
Main
4.1 13
6
8 0
108.0 ft2
0
0 0.6
0
9 N
Exterior
Concrete Block - Int Insul
Main
4.1 13
9
9 1
124.9 ft2
0
0 0.6
0
10 N
Exterior
Concrete Block - Int Insul
Main
4.1 20
4
9 0
183.0 ft2
0
0 0.6
0
11 -
Garage
Frame - Wood
Main
13 29
5
10 0
294.2 ft2
0
0.23 0.01
0
DOORS
#
Ornt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
-
Wood
Main
None
.25
2
8
6 8
17.8 ft2
2
S
Insulated
Main
None
.25
3
6 8
20 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall
Overhang
V # Ornt ID
Frame Panes NFRC
U-Factor SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1 W
1
Vinyl Low-E Double
Yes
0.33 0.23
N
16.2 ft2
1 ft 4 in
0 ft 10 in
None
Exterior 5
2 W
1
Vinyl Low-E Double
Yes
0.33 0.23
N
6.9 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
Exterior 5
3 S
4
Vinyl Low-E Double
Yes
0.33 0.31
N
4.0 ft2
11 ft 10 in
0 ft 8 in
None
None
4 S
4
Vinyl Low-E Double
Yes
0.33 0.31
N
6.7 ft2
11 ft 10 in
2 ft 9 in
Drapes/blinds
None
5 S
5
Vinyl Low-E Double
Yes
0.33 0.23
N
32.4 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
Exterior 5
6 E
.6
Vinyl Low-E Double
Yes
0.33 0.23
N
6.9 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
Exterior 5
7 E
6
Vinyl Low-E Double
Yes
0.33 0.23
N
16.2 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
Exterior 5
8 E
7
Vinyl Low-E Double
Yes
0.33 0.23
N
9.8 ft2
1 ft 4 in
0 ft 10 in
None
Exterior 5
9 N
9
Vinyl Low-E Double
Yes
0.33 0.23
N
16.2 ft2
11 ft 8 in
0 ft 10 in
None
Exterior 5
10 N
9
Vinyl Low-E Double
Yes
0.33 0.23
N
16.2 ft2
11 ft 8 in
0 ft 10 in
None
Exterior 5
11 N
10
Metal Low-E Double
Yes
0.55 0.7
N
20.0 ft2
11 ft 8 in
1 ft 0 in
Drapes/blinds
None
12 N
10
Vinyl Low-E Double
Yes
. 0.33 0.23
N
32.4 ft2
1 ft 4 in
0 ft 10 in
None
Exterior 5
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
610ft2 610ft2
56ft
8ft
1
4/21/2020 11:29 AM EnergyGauge@ USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
INFILTRATION
# Scope Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50)
.0004
1806 99.15 186.46 .1454
7
HEATING SYSTEM
# System Type
Subtype
Efficiency Capacity
Block
Ducts
1 Electric Heat Pump/
Split
HSPF:8.5 28.2 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Efficiency Capacity Air Flow
SHR Block
Ducts
1 Central Unit/
Split
SEER: 15 28.4 kBtu/hr 947 cfm
0.75 1
sys#1
HOT WATER SYSTEM
# System Type SubType
Location
EF Cap Use SetPnt
Conservation
1 Electric None
Garage
0.94 40 gal 60.9 gal 120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector
System Model # Collector Model # Area
Storage
Volume
FEF
None None
ft2
DUCTS
---- Supply ----
V # Location R-Value Area
---- Return --- Air CFM 25 CFM25
Location Area Leakage Type Handler TOT OUT
QN RLF
HVAC #
Heat Cool
1 Attic 6 344 ft2
Main
86 ft2 Default Leakage Main (Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: Y
CoolingJan Feb Mar
HeatinHJan HFeb Mar
Ventin Jan Feb X Mar
Ceiling Fans:
Jun X Jul Au Se
f Apr f I May Junf Jul AugSeP
Apr May ri
[X] A r [ Ma Jun [ Jul Au Se [X]
Oct Nov
Oct Nov
Oct X Nov
Dec
Dec
Dec
4/21/2020 11:29 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5
lA
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default 8 Ibs/sq.ft.
0 ft2
0 ft
0.3
Main
4/21/2020 11:29 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 97
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location
Main
3. No. of units (if multiple -family)
3. 1
4. Number of bedrooms
4. 3
13. Cooling system: Capacity
28.4
a) Split system SEER
15.0
5. Is this a worst case? (yes/no)
5. No
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6. 1720
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a. 0.354
b) Solar Heat Gain Coefficient (SHGC)
7b. 0.286
14. Heating system: Capacity
28.2
c) Area
7c. 183.7
a) Split system heat pump HSPF
8.5
b) Single package heat pump HSPF
S. Skylights
c) Electric resistance COP
a) U-factor: (weighted average)
8a. NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b. NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a. 0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.94
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF
2. Masonry (Insulation R-value)
10A2. 4.1
f) Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10131. 13.0
2. Masonry (Insulation R-value)
10132.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
a) Under attic
11a. 30.0
b) Cross ventilation
No
b) Single assembly
11b.
c) Whole house fan
No
c) Knee walls/skylight walls
11c. 19.0
d) Multizone cooling credit
d) Radiant barrier installed
11d. No
e) Multizone heating credit
f) Programmable thermostat
Yes
'Label required by Section R303.1.3 of the Florida
Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the
Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Signatyr
Date:
Address of New Home: 8704 Merano Avenue City/FL Zip: Fort Pierce, FL 34951
4/21/2020 11:30:03 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1