Loading...
HomeMy WebLinkAboutEnergy (EPL) Display Card-zeas- 0/,�� FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION .Florida Department of Business and Professional Regulation - Residential Performance Wow2010 Project Name: Lot 32 Block Waterstone 1720 BGL Builder Name: ADAMS HOMES ermitting Departmen St. Lucie Count Street: 8704 Merano Avenue Permit Office: y City, State, Zip: Fort Pierce, FL, 34951 Permit Number: Owner: Jurisdiction: 661000 Design Location: FL, ST_LUCIE_CO_INTL County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1665.3 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 1371.10 ft2 b. Frame - Wood, Adjacent R=13.0 294.17 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 10. Ceiling Types (1743.0 sqft.) Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=30.0 1720.00 ft2 6. Conditioned floor area above grade (ft2) 1720 b. Knee Wall (Vented) R=19.0 23.00 ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(183.7 sqft.) Description Area a. Sup: Attic, Ret: Main, AH: Main 6 344 a. U-Factor: Dbl, U=0.33 152.99 ft2 SHGC: SHGC=0.23 b. U-Factor: Dbl, U=0.55 20.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.70 a. Central Unit 28.4 SEER:15.00 c. U-Factor: Dbl, U=0.33 10.67 ft2 SHGC: SHGC=0.31 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 28.2 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 4.890 ft. Area Weighted Average SHGC: 0.286 14. Hot water systems a. Electric Cap: 40 gallons. 8. Floor Types (1720.0 sqft.) Insulation Area EF: 0.940 a. Slab -On -Grade Edge Insulation R=0.0 1720.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits Pstat Glass/Floor Area: 0.107 Total Proposed Modified Loads: 54.76 PASS Total Baseline Loads: 56.68 I hereby certify that the plans and specifications covered by Review of the plans and THEST,�p. this calculation are in compliance w' lorida Ener specifications covered by this Code. calculation indicates compliance y`a i/�� ' - ' with the Florida Energy Code. PREPARED BY: Before construction is completed DATE: 04-21-2020 Winn Keomany this building will be inspected for compliance with Section 553.908 0 ;d I hereby certify that this buildin esigned, is i ompliance Florida Statutes. ✓ �� . with the Florida Energy-Ge OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclos r a lle as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R4 ..1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 4/21/2020 11:29 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Building Type: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: Lot 32 Block Waterstone 172 Bedrooms: 3 User Conditioned Area: 1720 Total Stories: 1 1 Worst Case: No ADAMS HOMES Rotate Angle: 0 Cross Ventilation: No 661000 Whole House Fan: No Single-family New (From Plans) Address Type: Lot Information Lot # 32-1 Block/Subdivision: Waterstone PlatBook: Street: 8104 Merano Avenue County: St. Lucie City, State, Zip: Fort Pierce , FL, 34951 CLIMATE V Design Location Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Block1 1720 15480 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 1720 15480 Yes 4 3 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 171.5 ft 0 1720 ft2 ___- 0.26 0 0.74 ROOF V # Type Roof Gable Roof Materials Area Area Color Rad Solar SA Emitt Emitt Deck Pitch Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 1924 ft2 430 ft2 Medium N 0.85 N 0.85 No 0 26.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 1720 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 2 3 Knee Wall (Vented) Knee Wall (Vented) Under Attic (Vented) Main 19 Batt Main 19 Batt Main 30 Blown 5 ft2 0.11 Wood 18 ft2 0.11 Wood 1720 ft2 0.11 Wood 4/21/2020 11:29 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST RFPnRT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below _ 1 W Exterior Concrete Block - Int Insul Main 4.1 32 4 8 5 272.1 ft2 0 0 0.6 0 2 W Exterior Concrete Block - Int Insul Main 4.1 4 5 9 0 39.8 ft2 0 0 0.6 0 3 W Exterior Concrete Block - Int Insul Main 4.1 11 0 8 0 88.0 ft2 0 0 0.6 0 .4 S Exterior Concrete Block - Int Insul Main 4.1 5 9 9 0 51.8 ft2 0 0 0.6 0 5 S Exterior Concrete Block - Int Insul Main 4.1 12 0 8 0 96.0 ft2 0 0 0.6 0 _ 6 E Exterior Concrete Block - Int Insul Main 4.1 19 9 8 9 172.8 ft2 0 0 0.6 0 7 E Exterior Concrete Block - Int Insul Main 4.1 26 1 9 0 234.8 ft2 0 0 0.6 0 8 E Exterior Concrete Block - Int Insul Main 4.1 13 6 8 0 108.0 ft2 0 0 0.6 0 9 N Exterior Concrete Block - Int Insul Main 4.1 13 9 9 1 124.9 ft2 0 0 0.6 0 10 N Exterior Concrete Block - Int Insul Main 4.1 20 4 9 0 183.0 ft2 0 0 0.6 0 11 - Garage Frame - Wood Main 13 29 5 10 0 294.2 ft2 0 0.23 0.01 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 - Wood Main None .25 2 8 6 8 17.8 ft2 2 S Insulated Main None .25 3 6 8 20 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 W 1 Vinyl Low-E Double Yes 0.33 0.23 N 16.2 ft2 1 ft 4 in 0 ft 10 in None Exterior 5 2 W 1 Vinyl Low-E Double Yes 0.33 0.23 N 6.9 ft2 1 ft 4 in 0 ft 10 in Drapes/blinds Exterior 5 3 S 4 Vinyl Low-E Double Yes 0.33 0.31 N 4.0 ft2 11 ft 10 in 0 ft 8 in None None 4 S 4 Vinyl Low-E Double Yes 0.33 0.31 N 6.7 ft2 11 ft 10 in 2 ft 9 in Drapes/blinds None 5 S 5 Vinyl Low-E Double Yes 0.33 0.23 N 32.4 ft2 1 ft 4 in 0 ft 10 in Drapes/blinds Exterior 5 6 E .6 Vinyl Low-E Double Yes 0.33 0.23 N 6.9 ft2 1 ft 4 in 0 ft 10 in Drapes/blinds Exterior 5 7 E 6 Vinyl Low-E Double Yes 0.33 0.23 N 16.2 ft2 1 ft 4 in 0 ft 10 in Drapes/blinds Exterior 5 8 E 7 Vinyl Low-E Double Yes 0.33 0.23 N 9.8 ft2 1 ft 4 in 0 ft 10 in None Exterior 5 9 N 9 Vinyl Low-E Double Yes 0.33 0.23 N 16.2 ft2 11 ft 8 in 0 ft 10 in None Exterior 5 10 N 9 Vinyl Low-E Double Yes 0.33 0.23 N 16.2 ft2 11 ft 8 in 0 ft 10 in None Exterior 5 11 N 10 Metal Low-E Double Yes 0.55 0.7 N 20.0 ft2 11 ft 8 in 1 ft 0 in Drapes/blinds None 12 N 10 Vinyl Low-E Double Yes . 0.33 0.23 N 32.4 ft2 1 ft 4 in 0 ft 10 in None Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 610ft2 610ft2 56ft 8ft 1 4/21/2020 11:29 AM EnergyGauge@ USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .0004 1806 99.15 186.46 .1454 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:8.5 28.2 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 15 28.4 kBtu/hr 947 cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.94 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None ft2 DUCTS ---- Supply ---- V # Location R-Value Area ---- Return --- Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT QN RLF HVAC # Heat Cool 1 Attic 6 344 ft2 Main 86 ft2 Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y CoolingJan Feb Mar HeatinHJan HFeb Mar Ventin Jan Feb X Mar Ceiling Fans: Jun X Jul Au Se f Apr f I May Junf Jul AugSeP Apr May ri [X] A r [ Ma Jun [ Jul Au Se [X] Oct Nov Oct Nov Oct X Nov Dec Dec Dec 4/21/2020 11:29 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5 lA FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibs/sq.ft. 0 ft2 0 ft 0.3 Main 4/21/2020 11:29 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 97 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Main 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 28.4 a) Split system SEER 15.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 1720 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.354 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.286 14. Heating system: Capacity 28.2 c) Area 7c. 183.7 a) Split system heat pump HSPF 8.5 b) Single package heat pump HSPF S. Skylights c) Electric resistance COP a) U-factor: (weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.94 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10131. 13.0 2. Masonry (Insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11a. 30.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11c. 19.0 d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat Yes 'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signatyr Date: Address of New Home: 8704 Merano Avenue City/FL Zip: Fort Pierce, FL 34951 4/21/2020 11:30:03 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1