CONNECTORS SCHEDULE
ROOF TRUSS
Q
ID
MODEL ROOF UPLIFT SYM
0
A'
LUS24 / JUS24
895 / 835
490 /610
ILA•
10
A
HTU26/ THD26
3600 / 3470
1555 / 2330
ILA
0
B
HTU28 / THD28
4680 / 5040
2140 / 2330
AILS
0
C
HTU26-2 /THD26-2
3600 / 3355
2175 / 2340
I LC
0
D
HTU28-2 / THD28-2
4680 / 6005
3485 / 2595
1 11P
0
E
HGUS26-2 / THDH26-2
5320 / 5245
2155 / 2340
I LE
0
F
HGUS28-2 / THDH28-2
7460 / 8025
3235 / 3330
11
0
G
HGUS26-3 / THDH26-3
5230 / 5245
2155 / 2340
I LG
0
H
HGUS28-3 / THDH28-3
7460 / 7836
3235 / 4370
1 IH
2
J
THJA26 / HJC26
9100 / 8990
4095 / 4370
1 Li
3X8NOP
TO APPROVAL
MAIN VAND FORCE RESISTING SYSTEWCC HYBRID VAKID ASCE740
IMPORTANT
ENCLOSED
EJlPOSURE CATEGORY C
OCCUPANCY CATEGORY 0
This Drawing Must Be Approved And
WILOA N
D A BWANCEE FACTOR 1.00
TRUSSEESS HAW WHO
BEEN DESIGNED FORA 10.0 PSF BOTTOM CHORD
LIVE LOAD
Returned Before Fabrication Will
Begin. For Your Protection Cheek All
NONCONCURREN7 WRH ANY OTHER LNE
LOADS
Dimensions And Conditions Prior To
APprova
BELO Of Plan.
SIGNATURE BELOW INDICATES ALL
ROOF LOADING
- FLOOR LOADING
NOTES AND DIMENSIONS HAVE
TCLL: 20 PSF
TCLL•
40 PSF
BEEN ACCEPTED.
TCDL: 07 PSF
TCDL:
10 PSF
By Date
BCDL: 10 PSF
BCDL:
5 PSF
TOTAL: 37 PSF
TOTAL:
55 PSF
DURATION: 1.25
DURATION:
1.00
CAUTION!!!
DO NOT ATTEMPT TO ERECT
TRUSSES WITHOUT REFERRING TO
THE ENGINEERING DRAWINGS AND
BSCI-B1 SUMMARY SHEETS.
ALL PERMANENT BRACING MUST BE
IN PLACE PRIOR TO LOADING
TRUSSES. (ie. SHEATHING,
SHINGLES, ETC.) - ^T
ALL INTERIOR 6EARIN6 -%WALLS
.MUST BE IN PLACE PRIOR TO
IASTALLING'TRUSSES.::
,ENGINEERING
REFER TO FINAL
SHEETS FOR THE FOLLOWING.
4), NUM BEWOF(GIRDERtF?LIES• AND
NAILING SCHEDULE
;2) SEARING Bf SCI .-RE91.11REMENTS.
3j SCAB DETAILS JIE REQUIRED); ,
4) UPLIFT AND iGRAVITY REACTIONS.
• • :' WARNING
Backcharges Will Not- Be Accepted
Regardless of Fault Without Prior
Notification By Customer Within 48
„ Hobrs And Investigation By -
•= :- Builders First Source.,,( ,
.-..NO EXECPTIONS.
The General Contractor Is Responsible
For All Connections Other Than Truss
. to.,Truss, Gable Shear Wall, And
=? 6n9eet16ri ,.T6mpoFdry and
Permanent Bracing, And Ceiling And
Roof Diaphragm Connections.
ROOF PITCH: 6112
r
CEILING PITCH: 0/12 •
- TOP CHORD -SIZE: �" 2 X 4
BOTTOM CHORD SIZE: 2 X 4
OVERHANG LENGTH: 16"
END CUT: Plumb
CANTILEVER: —
TRUSS SPACING: 24"
BUILDING CODE: FBC2D17
BEARING HEIGHT SCHEDULE
Hatch Legend
=8'
Truss Bearing
BUILDER:
Adams Homes
PROJECT:
Single Family
MODEL:
LANAI
ADDRESS: 1 8704 MERANO AVE
LOT I BLOCK:
3211
SUBDIVISION-1
LUCIE COUNTY
—
CITY: FORT PIERCE
DRAWN BY: K SANCHEZ
JOB p : 1 2254612
DATE: 02/20/2020 SCALE: F NTS
PLAN DATE: 1 2020
REVISIONS:
1.
2.
3.
4.
FB,u�ildners
L'1 ur
4408 Airport Road
Plant City, FL 33563
Ph. (813) 3054300
Fax (813) 305-1301
fiF; D 181
ENGINEERING ASSOCIATES
February 25, 2020
Building Department
Ref:
Lot:,
Subdivision:
Address:
Model: .
Truss Company:
Date of drawings:
Job No.:
Wind Speed:
Exposure:
Truss Engineer:
249 Maitland Avenue, Suite 3000
Altamonte Springs, Florida 32701
P: (321)972-0491 F: (321)972-0484 1 E: info@fdseng.com
Website: www.fdseng.com
Adams Homes
Lot 32 Blk 1 .
Fort Pierce - Waterstone
8704 Merano Ave.
1720 B LHG
%XIIIChy/
Builders First Source
2/20/20
2254612
160
C
Thomas A. Albani
To whom it may concern,
RECEIVED
MAY 0 7 7.020
Permitting Department
St. Lucie County
We have reviewed the truss design package for the project referenced above. This truss package
complies with the original design intent and the underlying structure will accommodate all
indicated loads. We approve the truss package without comment based upon the truss layout and
truss profiles supplied to us by the Truss Company with truss profiles sealed by the Truss
Engineer.
Please note, this review is only for general conformance with the design concept of the project.
Contractor or sub -contractor is responsible for matching all structural components and details
shown in the construction documents. Contractor or sub -contractor is also responsible for
confirming all quantities and dimensions; selecting appropriate fabrication processes and
techniques; and coordinating work with all other trades.
Note: Truss ID's may vary.
�@0adtilolla®se�J
If you have any questions, please do not A �tfb ca14&
a
o ••I- CC'• T0eee
Sincerely, vi.•'.•• No
a � • 19(94 r
.o
r �
y tp
,,^^
0. .0 .•Q.�O
.�
oo,r �-�aG��.%%
2/25/2020
Carl A. Brown, P.E. Luis Pablo Torr s;ll' Todd M. Born, P.E.
FL. # 56126 FL. # 87864 FL. # 82126
"Doing Business with a Service Mindset and an Eye for Detail"
Lumber design vafu s`are irraccordance with ANSI/TPI 1 section 6:3 .
These truss .design," 6 lumber values established by others.
MAY A 7n7n:jMiTek.
.:. n Department,... ` Permitting
. .
RE: 2254612 - LOT 32/1 WATERSTONE:. MiTek USA, Inc..
.::..:Site Information::: Pa 6904 rke East.Blvd.
a Fl g3 1 =4115
Customer Info: Adams Homes. Port St Lucie Project Name: 2254612 . Model: 1718$C.114
Lot/Block: 32/1 Subdivision: Waterstone-St Lucie County'
Address: 8704 Merano Ave:, .
: City: Fort Pierce .: State: FL
Name Address and License.# of Structural Engineer of Record, If there is one, for the building.
Name License # :..
Address:
City: State:
General -Truss Engineering Criteria & Design; Loads (Individual. Truss Design Drawings Show Special.
Load! ng.Conditions):.
: Design Code: FBC201 W P12014 .:. Design Program: MiTek 20/20 8.2
Wind Code:. ASCE.7-10 Wind Speed: 160 mph .
Roof Load: 37.0 psf Floor Load:.N/A psf
This package includes 40 individual,: Truss Design Drawings and 0 Additional Drawings.
With my.seal affixed to this. sheet I hereby certify.that I am the Truss Design Engineer.and this index sheet ...
conforms to 61 G15-31..003, section 5 of the Florida Board of Professional Engineers.Rules.
No. Seal#
Truss Name .:Date : •: No. Seal# : ::Truss Name.: Date .
1 T19470841 A01 2/20/20.. 23 T19470863 _C7V ..2/20/20
2. . , T19470842 A02S _ 2/20/20 24 . T19470864 E3 2/20/20 .. . .
3:.: _.T19470843 A03S :. 2/20/20 25- T19470865 E5 : 2/20/20
4 T19470844 A04. 2/20/20 26.. T19470866 E5P... 2/20/20
5 T19470845 A04A 2/20/20:: 27 T19470867 E7 2/20/20:
6 T19470846 A05 2/20/20 28 T19470868 . 'E08 .2/20/20
7 T19470847 A06 2/20/20:: 29 T194,70869 :EJ08 2/20/20:
8. T1,9470848 A07 2/20/20 3.0: T19470810 G01: _ : 2/20/20
9 ..:.T19470849 A08 2/20/20 31 T19470871 H3 .::- 2/20/20
10 .. T1:9470850 AM: .. 2/20/20 32, T.19470872 H5 .: 2/20/20
11 T19470851.: A10 2/20/20:: 33 T19470873 .H5P 2/20/20
.12 T19470852 1301 .2/20/20 .34 T19470874 .H7 2/20/20.
13 T19.470853 B02 :2/20/20 35 T19470875 H7V 2/20/20
14 :;. T19470854 B03 : : 2/20/20 36: T-19470876 K01: : 2/20/20
15 T19470855 C1 2/20/20 37 : T19470877 K02 2/20/20
..16 T19470856 C1.P 2/20/20 38 T19470878. L07 2/20/20
.7 17 T1947085: C1 V 2/20/20 39 T19470879. L08 .2/20/20
18 T19470858 C3 2/20/20.. 40 T19470880 L09 .2/20/20 ...
19 . • T19470859 C3P . 2/20/20
20.:: T19470860 C3V 2/20/20
21 T19470861 C5 2/20/20
: 22 T19470862 C5V 2/20/20
The. truss drawing(s) referenced above have lieen.prepared by �% A� �i�� .....
MiTek USA, Inc. under my direct supervision based on the parameters `����.Z• • N Se-9,L� ���'
provided by Builders FirstSource (Plant City, FL). .
39 80
Truss Design Engineer's Name: Albani, Thomas
My license renewal date for the. state of Florida is February 28, 202 L= k
.
'0
IMPORTANT: NOTE: The seal on these truss component designs is a certification i S
that the engineer named is. licensed in the jurisdiction(s) identified and that the ���.(�' • �`. QP .� ��: -
designs comply with ANSI/TPI. 1. These designs are based. Upon parameters R 1 ��
shown (e..g:, loads, supports, dimensions, shapes and design codes), which were ��j S "• • �� ��
TRENCO's customers fi eOreferencerpu posect eeonly,� and was not taken into aion included is ccount n the �i N lilt.
iven to MiTek .
preparation of: these designs. MiTek orTRENCO has not independently verified the Thomas A.Alban! PENo.39380,
applicability of the design parameters or the designs for any particular building. Before use, MITek USA ,;Inc. FL Cert 6634
the building.designer should verify applicability of design parameters and properly 6904 Parke East Blvd, Tampa FL 33610
incorporate these designs into the overall building .design per ANSIITPI 1, Chapter 2. Date:
February 20,2020.
Albani, Thomas.. 1 of 1
Job
Truss
Truss Type
O}y
Ply
LOT 32/1 -WATERSTON E
T19470841
2254612
A01
Roof Special Structural Gable - .
1
1
Job Reference (optional)
Cimuers rrrslJOUrce Imam yity, r-L/; want Uty, t-L - 33bb/, _ . b.G4u S rep t 'LU2U MI I eK Industries, Inc. I nu hen zu 11:16:37 2u2u � Page 1
ID:v3HtyczpY..vZl 1 rn?gXrhK6yOc4g-ugdzW rtkO6BJXvUgACQ5968P.Yx9KVR2fM3XgA94G68
r1-4.0; 6-0-0 11-11-4 i9.0-0 19,2-0 25-1-13 31-3-11 38.0.0 39.4-Q
1-4-0' 6-0-0 5-11-4 7-0=12 0-�-0 5-11-13 6=1-13. 6-8.5 1-4-0
..
Scale = 1:70.2
5x8 =
6.00
.. 6 7 .. ..
. ..30... ea 4x6 =
' . 1.5x8 STP = �5 24 23 .22 21 20 18-1018 18 17 16
.. ..
. .. 3x6 '
6x8.= 3x6:= .. ..
6 0 0 11-7-10 11-,1,1-4 19-1-13 19-2-0 27-9 2 38 0 0
. .. 6-0-0 5-7-10 0- .10 7-2-9 0- -3 B-7=2 - 10-2.14
Plate Offsets (X,Y)-- [5:0-1-9,Edge], [7:0-1-12,0-0-14], [11:0.1-9;Edge], [26:0-3-8,Edge], [26:0-1-12,0-0-0], [27:0-0-0,0-1-12]:
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc), . I/deft ' Ud
PLATES : GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0:64
Vert(LL) -0.13' 27-28 >701 240
MT20 p 244/190
TCDL 7.0
Lumber DOC 1.25
BC:':.0'60
Vert(CT): -0.20 27-28 >461 180:.
BCLL 0.0 '.
Rep Stress Incr YES
WB 0.46
Horz(CT) 0.64 . 14 n/a n/a
BCDL 10.0
Code: FBC2017/fP12014:
Matrix -AS
a
Weight:251 lb FT=20%
LUMBER- BRACING-
..
.
TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly
applied.
BOT CHORD 2x4 SP No.2 `Except' . BOT CHORD Rigid ceiling directly applied.
.. ... 4-2917-25: 2x4 SP No.3: 22-25,14-22: 2x4 SP No.2. P WEBS 1 Row at midpt 8-24
WEBS 2x4 SP No.3. .. .:..
OTHERS 2x4 SP Nb:3 "
REACTIONS.. :All bearings 18-10-0 except at=length) 2=0-8-0, 29=0 7-4.
(lb) - Max, Horz 2=418(LC 11)
Max Uplift . All uplift:100 lb or less at joint(s) 24, 20, 18, 17 except 2=-463(LC.12),
26=-107(LC 11), 23=-116(LC 12), 21=-162(LC 12), 19=-529(LC.12), 16= 221(LC
„ 12), 14=-273(LC 12), 29=-567(LC 12):
Max Grav All reactions 250 lb br less at joint(s) 25, 25, 24, 23, 21, 20, 18, 17,
14, 14 except 2=481(LC 1), 26=711(LC 17), 19=550(1_C 18), 16=312(LC 18),
29=960(LC .17) . .
-FORCES. (lb) - Max. Comp:/Max. Ten. - All forces 250 (lb) a? less except when shown.
TOP CHORD .2-3=-590/567, 3-4=-336/396, 4-6=-281/635, 6-7= 266/552, 7-8=,-270/722, 8-9==264/688. .. ...
9-10=-229/615, 10-12=-177/525, 12-13=-227/566, 13-14=-89/303
BOT CHORD 2-30=-322/463, 29-30=-322/463, 28-29=-646/477, 4-28=458/518, 7-26=-396/1
WEBS 3-30=0/269, 13719= 517/570, 3-29=-585/378. ..
NOTES-
1) Unbalanced roof live loads have been considered forthis design. -.
2) Wind: ASCE'7-10; Vult=160mph (3-se6ond gust) Vasd=124mph; TCDL=4.20sf; BCDL=6.Opsf; h=25ft; B=45ft; L=40ft; eave=6ff; Cat._'
11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-4-0 to 2-8-0, Interior(1) 2-8-0 to 19-0-0, Exterior(2) 19; 0-O to
23=0-0, Interior(1) 23-0-0 to 39-4-0 zone;C-C for members and forces & MWFRS.for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) Truss designed for wind loads in the plane of the truss.only. For studs exposed to. wind (normal to the face), see Standard: Industry
Gable End Details as applicable, or consult qualified building designer as.per:ANSI/TPI 1.
4) All plates are 2x4 MT20 unless otherwise indicated.
5) Gable studs spaced at 2-0-0 oc.
6) This truss has been designed for. a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) *.This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the.bottom chord and any other.members, with BCDL = 10.0psf.
8) Lumber designated with a "P" is pressure -treated with preservatives. Plate. lateral resistance valbes,have been reduced 20% where,
Thomas A: Alban) PE N6.36360
used in this lumber. Plates should be protected from corrosion per the recommendation of the treatment company. Borate or other.
MiTek USA, Inc. FL Cert6634
be suitable treatment may usecljf it does not corrode the plates. If ACQ, CBA, or CA-B treated lumber is used, improved corrosion
" protection is required, and.G185 galvanized plates maybe used with this design. Incising factors have not been considered for this
6904 Parke East Blvd. Tampa FL 33610 .
design. Building designet "to verify suitability of this product for its intended use.
Date:
9) Bearings are assumed to be: Joint 2 SYP No:2:crushing capacity of 565 psi, Joint 29 SYP N6.2 crushing capacity of 565 psi, Joint..
February 20,2020 .
In car)acitv of 565 6si.
Al, WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MI1-7473 rev. IOIOW015 BEFORE USE.
- Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, note
..
a. truss system. Before use, the building designer must verify The applicability of design parameters and properly Incorporate This design Into. the overall
-building design. Bracing Indicated, is To prevent buckling of individual Truss web and/or chord members only. Additional.temporary'and permanent bracing..
MOW
always required: for stability and to prevent collapse with possible personal Injury and:property damage. For general guidance regarding the: • . -
..
-
fabrication; storage, delivery, erection and bracing of trusses and truss systems, seeANSV711 Quality CrBada,'DSB-69 and BCSI Bu9ding Component
6904 Parke -East Blvd..
Safety Informafbnavailable from Truss Plate Institute, 2.18 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 33610
'
Job
Truss
Truss Type
qy.
Ply
LOT 32/1 WATERSTONE
T19470841
2254612
A01 ' :
Roof Special Structural Gable .. ..
1
1
Job Reference (optional)
' WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED M?EK REFERANCE PAGE'M11-7473 rev. f0/03/2015 BEFORE USE.
- Design valid for use only with Mrrek® connectors. This design Is based only upon parameters shown, and is for an Individual building component not
a, truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into, the overall
building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporaryand permanent bracing..
MiTek'
is always required for stability and to prevent collapse with possible personal Injuryand property damage. For general guidance regarding the: ..
p
fabrication; storage, delivery, erection and bracing of trusses and truss systems, seeANSI/Tpll Cuallh CAtoAa, DSB-69 and SCSI Building Component:
6904 Parke East Blvd.
Safuty Informatlonavoilable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22914.
Tampa, FL 33610
Job
Truss
Truss Type
03y
Ply
LOT 32/1 WATERSTONE
K
T19470842
2254612
A02S .
ROOF SPECIAL
3
1
Job Reference (optional)
ouuugrs rlrstJOUrce trlapt Ulry, rLJ1 r iani lily, rL - 00001, _ t5.Z4u s reo r zuzu MI I eK Inauslnes,:inC. I nu rep ZU 11:16:4Z Zulu rage 1
ID:v3HtyczpY.vZ11 rn?gXrhK6yOc4g-EdQsZZxtremcdgMezlOGsArlvynfAeMPV.LERrMzjG63
rl-4.0 6-7-10 8-8-0 12-9-13 18-0-12 19-0-P 25-2-3 31-3-11 38-0-0
1-4-0 6-7-10 2-0-6 4-1-13 5-2=15 11- 6-2-3 6-.1-8 . 6-8.5
3x6 = Scale =1:70.5 '
6.00 12. ... 2 ..
x4 11
5 6
5x6 i 24
23 5x6
22
1.5x8 STP'=
0 1��
.. .. .. .. ... 13 26' 12 1 ...10
.:
1. 58STP 36 4
3.00 12 : x = x = 2x 11
3x 6
3x6 —
6x8 —: 3x4 = .:.
8 8 0 18=0-12 18 -6 25-2-3 31-3-11
38-0-0
8-8-0 . 9-4-12 0- -10 6-9-13 6-.1-8 .
6-8--5
Plate Offsets (X,Y)-- [2:0-0-10,Edge], [4:0-3-0,0-3-0], [6:0-3-0,Edge], [7:0-3-0,0-3-0]
LOADING (psf)
SPACING- 2-0=0
CSI.
DEFL. in (loc), I/defl Ud
PLATES GRIP
TUC 20.0 : : :
Plate Grip DOL 1.25
TC 0: :
Vert(LL) -0.21 14-15 >999 240
MT20-244/190
TCDL .7.0
Lumber DOL :. 1.25
.54
...
BC:,: 0.91
Vert(CT): : -0.42 14-15 >514 180
BCLL 0.0
Rep Stress Incir YES
WB . 0.72
Horz(CT) 0.11 13 n/a n/a
BCOL 10.0
Code.. FBC2017/TP12014
Matrix -AS
Weight:106Ib FT=20
LUMBER- BRACING -
TOP CHORD 2x4�SP No.2 TOP CHORD : Structural wood sheathing directly applied.
BOT CHORD 2x4 SP No.2 *Except* . BOT CHORD Rigid ceiling directly applied.
5-13: 2x4 SP No.3 .. WEBS 1 Row at midpt. 7-13
WEBS 2x4 SP No.3.
REACTIONS. (lb/size) 2=680/0-8-0, 13=1535/0-7-4, 9--669/Mechanical
Max Harz 2=412 LC 11
Max. Uplift 2=-579(LC 12), 13= 633(LC 12), 9=-487(LC .12)
Max Grav 2=685(LC 21), 13=1544(LC.17), 9=789(LC 16)
FORCES. (lb) - Max. Comp./Max: Ten. - All forces 250 (lb) or less except when shown...
TOP CHORD 2-3=-1591/1380, 3-4=-1288/11591'4-5=-201/454, 5-6=-174/480,.6-7=-142/462,
7-8=-777/710,8-9=-1294/954
BOT CHORD. 2-15= 1112/1676, 14-15==365/4913, 13-14=-1116/407, 5-14=-532/55, 12-13=-306/573,
10-12=-705/11011.9-11101
WEBS 4-15=-499/1080, 4-.14=-767/664, 7-12=-172/515, 8-12=-609/500, 8-10=01257,
7-13=-893/580, 3=15=-434/445 ...
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult-160mph'(3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=6.Opsf; h=25ft; B=45ft; L=40ft; eave=6ft; Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-4-0 to 2-8-0,.Interior(1) 2-8-0 to 19-0-0,.Exterior(2).19-0-0 to
23-0-0, Interior(1) 23-0-0 to 38=0-0 zone;C-C for members and forces & MWF.RS for reactions shown; Lumber DOL=1.60 plate. grip.
DOL=1.60
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads:
4) * This truss has been -designed for a live load of 20.0psf on the bottom chord in all, areas where a rectangle 3-&0 tall by 2-0=0 wide
"
will fit between the bottom:chord and any other members,. with BCDL = I O.Opsf.
5) Bearings are assumed to be: Joint 2 SYP No.2 crushing capacity of 565 psi, Joint:13 SYP No.2 crushing capacity of 565 psi..
6) Refer to girder(s) for truss to truss connections:.:
7) Bearing atjoint(s) 2 considers parallel to grainvalue using ANSI/TPI 1 angle.to.grain formula. Building designer should verify
capacity of bearing surface. . ....
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding.100 lb uplift at joint(s) except Qt=1b)
2=579, 13=633, 9=487.
9) This truss design requires that a minimum of 7/16" structural wood sheathing. be applied directly to the top chord and 1/2" gypsum
sheefrock be applied directly to the bottom chord:
Thomas A: Albani PE fJ6.39386
II USA, Inc. FL Cett6634
6164 Parke East Blvd. Tampa FL 33610
. Date: .
February 20,202
0 :WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MIF7473 rev. 1010312015 BEFORE USE;
"
Design valid for use onlywith MiiekO connectors. This design Is based only upon parameters shown, and Is for an Individual building Component, not
a,truss system. Before use, the building designer must verity the applicability of design parameters and properly Incorporate this design into. the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members,only. Additional temporary'and permanent bracing .
MITek'
Is always:required for stability and to prevent -collapse with possible personal Injury and:property damage. For general guidance regarding the
fabrication; storage, delivery, erection and bracing of trusses and truss systems, seeANSI/iPll Quality Cdtaida, DSB-69 and SCSI Buading Component:.
6904 Parke East Blvd.
Safety Informatlonavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss . . ..
Truss Type
o4y.
Ply
LOT 32/1 WATERSTONE
Y
T1947OB43
2254612
A03S"
ROOF SPECIAL
7
1.
17208:
Job Reference (optional)
Duuuers mrstaourue tma!n yrty, rL)i riant Vlty, rL - J'JOol, _ _ _ _ ts.z4u s reD t zuzu MI I eK Inousines,:inc. t nu req zu l l :l ts:4a zuzu rage 1 .
" "' ID:v3HtyczpYvZl1m?gXrhK6yOc4g-3nn7pcOeQUWILbgoJO6g6R5E7MgUaKEHtHhm2OzjG5z
r1-4-0 ' 6-7-10 12-9-13 19.0-0 _25-2-3 31-4-6 38-0-0
1-4-0 6-7-10 6-2-3 6-2-3 6-2-3 6-2-3 6-7-10 .
Scale = 1:67.8
5x6
6,00 F12
S .. ..
... : 5x6 i 23 24 - .. ..
5x6
4.. 6
2x4 2x4 �/
3 7
22
1.5x8 STP =
c" 2
ej 1
25
0
8 m N'.
Ia
:.. .. �.. ... _... ..
p
18-3-10 12 11
3x6 = 6x8 =
5x8 2x4
� 3.00 12
3k6 =
8-8.0 15-6-11 18-10-419tQ-0 28-1-14
38-0.0
8-8.0 6-10-11. 3-3-9 0-1-12 9-1-14
9-10-2
Plate Offsets (X,Y)-- [2:0-2-7,Edge], [4:0-3-0,0-3-4], [6:0-3-0,0-3-0], [8:0-2-12,0-1-81, [9:0-2-9,0-2-4], [13:0-5-8,0-3r41, [15:0-4-0,Edge]
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc), I/defl . Ud
PLATES' GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0:94"
Vert(ILL) : 0.62 14-15 >741 240
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC: :.0.94
Vert(CT): .: 0.78 14-15 >585 180 :.
BCLL .0.0 *.'
Rep Stress Incr YES
WB . 0.88
Horz(CT) 0.37 . 8 n/a n/a
BCDL 10.0
Code FBC2017lTPI2014:
Matrix -AS
Weightr212Ib FT=20%,
LUMBER- BRACING-
.. ...
TOP CHORD 2x4:SP No.2 TOP CHORD Structural wood sheathing directly applied.
BOT CHORD 2x4 SP No.2 'Except" . BOT CHORD Rigid ceiling directly applied.
2-18,8-10: 2x4 SP No.i WEBS- 1 Row at midpt. 9.13
WEBS 2x4 SP No.3
WEDGE
Left: 2x4 SP No.3
REACTIONS. (lb/size) 2=1486/0-8=0,.8=1412/Mechanical
Max Harz 2=412(LC 11)
Max Uplift 2- 904(LC 12), 8=-786(LC 12):
FORCES. (lb) -: Max. Comp./Max. Ten. -All forces:250 (lb) or less except when shown.
TOP CHORD 2-3=-4684/2777, 3-4=4394/2602, 4-5=-2581/1714, 5-6=-2090/1434, 6-7=-2436/1598,
7-8=-2672/1714
BOT CHORD 2-15=-2425/4398, 14-15=-1430/2777, 13-14=-731/1803, 8-9=-1386/2352 .
WEBS 3-15=r303/886, 4-15=-888/1797, 4-14=4049/787, 5-14=-666/113Q,9-T8= 1105/2124,
6-13=-519/453, 7-9=404/458, 5-13=-428/780
NOTES- .
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=6:0psf; h=25ft; B=45ft; L=40ft; eave=6ft; Cat.
11;, Exp C; Encl., GCpi=0.181 MW FRS (directional) and C-C Exterior(2) -1-4-0 to 2-8-0, Interior(1) 2-8-0 to 19-0-0,. Exterior(2) 19-0-0 to
23-0-0, Interior(1)23-0-0 to 38-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate. grip
DOL=1.60 .. ...
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads:
4) .*This truss has been designed for alive load of 20.Opsf on the bottom chord in all. areas where a rectangle 3-6-0 tall by 2-0=0 wide
will fit between the bottom:chord and any other members.
5) Refer to girder(s) for truss to truss: connections.
6) Bearing at joirit(s):2 considers parallel to grain value using ANSI/TPI 1 angle, to grain formula. Building designer should verify
capacity of bearing surface.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 Ib uplift at joint(s) except Qt=1b)
2=904, 8=786.
8) This truss design requires that a minimum of 7/16".structural wood sheathing be applied directly to the top chord and 1/2" gypsum
sfieetrock be applied directly to the bottom chord.
Thomas A. Albani PE No.39380
MiTek USA, Ina FL Cod 6634
6904 Parke East Blvd. Tampa FL 33610
Date: .
. ..
February 20,2020
O :WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE'M11.7473 rev. 1010312015 BEFORE USE;
°
Design valid for use only with. MITek® connectors. This design is -based only upon parameters shown, and is for an individual building component, not
a.truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into. the overall
building design, Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing .
MITek"
Is always required. for stability and to prevent collapse with possible personal injury.and:property damage. For general guidance regarding the: .. .
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSVIPIi Quality Criteria, DSB49 and 1 I Building Component
6904 Parke East Blvd..
Safety Infonnatlonovalloble from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Oyy
Ply
LOT 32/1 WATERSTONE
x
T19470844
2254612
A04
Roof Special
6
J.
Job Reference (optional)
ouuutvtn ntatouutua trtatu �Ry, rt-l; riant ugly, rt_ - odop r, _ mz4u s reo r eueu MI t eK mausines, Inc.. I nu reo zu 11:16:bU zUZU: rage 1
ID:v3HtyczpYvZl.im?gXrhK6yOc4g-?AvuE12uy5nTbvzARR98BsBZgAW32EEaLbAt6vzjG5x
r1-4 0 6 7 10 12-9-13 19.0-0 25-2-3 31-4-6
38-0-0 a9-4-q
1-4-0 6-7-10 6-2-3 6-2-3 6-2-3 6-2-3
6-7-10 . 1-4-0
Scale = 1:68.6
Sx6.
6.00 12:
.. ... .. ...
5
5x6 i 23 . :. .
22
5x6 .. .
4 6
2x4 Q
2x4
3
7. "
1.5x8 STP =
21
P4.
1.5x8 STP = • 14
2 13 25 12 11 10
a�= . .
0 I 1 6x12.MT20HS3x4 = 3x6 3x4 = 6x12 MT20HS =
. ..
b
8 9 a'
- J
o
.: ..' .. '. .:.. ..
5x8 Zzz
5x8 % 3:00 12
6-8 15-6-13 : 22-5-3 29-4.0
38 0 0
8-8-0-0 6-10-13 .. 6-10-6 6-10-13
8-8-0
Plate Offsets (X,Y)-- [2:0-2-7,Edge], [4:0-3-0,0-3-41,[6:0-3-0;0-3-4], [8:0-2-7,Edge] .
LOADING (psf)
SPACING- 2-0=0
CSI.
DEFL. in (loc), I/defl Ltd
PLATES, GRIP
TCLL 20.0 :
Plate Grip DOL - 1.25
TC 0:93 :
Vert(LL) 0.73 13-14 >622 240
MT20 244/190
TCDL .7.0
Lumber DOL :. 1.25
BC: ..0.94
Vert(CT): -0.94 13-14 >486 180 :.
MT20HS 187/143
BCLL .: .0.0 *.:
Rep Stresslncr YES
WB .0.85
Horz(CT)'. 0.59' 8 n/a n/a.
BCDL 10.0
Code FBC2017/TP12014.
Matrix -AS
p
Weight:.102 lb FT = 20
LUMBER- BRACING-
.. ...
.. .
TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied.
BOT CHORD 2x4 SP No.2 *Except* BOT CHORD Rigid ceiling directly applied.
2-14,8-10: 2x4 SP No.i
WEBS 2x4 SP No;3,
WEDGE
Left: 2x4 SP No.3; Right.: 2x4 SP No:3
REACTIONS. (lb/size) 2=1478/0-&O, 8=1478/0-8-0
Max Harz 2=418(LC 11)
Max Uplift 2=-906(LC 12), 8=-906(LC 12) :.
FORCES. (lb).- Max. Comp./Max. Ten. -All forces:250 (lb) or less except when shown.
TOP CHORD 2-3=-4725/2756, 3-4=-4432/2568, 4-5=-2555/1699, 5-6=-2555/1687, 6-7=-4360/2558',i:
7-8= 4651/2735
BOT:CHORD 2-14=-2322/4571, 13-14=-1321/2927, 11-13=684/1851, 10-11=-1370/2721,...
..
8-10=-2351/4197 .
WEBS .5-11.=-642/1154; 6-11=-996/781, 6-10=-869/1678, 7-10=-310/388, 5-13=-633/1218,
" 4-13=-1064/772, 4-14=-872/1831; 3-14=-297/386
NOTES-.. ...
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160niph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=6.Opsf; h=25ft; B=45ft; L=40ft; eave=6ft; Cat.
11; Exp.C; Encl., GC01=0.18; MWFRS (directional) and C C Exterior(2), -1-4-0 to:2=8-0, Interior(1),2-8-0 to 19.0-0, Exterior(2) 19-0-0 to
23-0-0, Interior(1) 23-0-0 to 39-4-0 zone;C-C for members and forces :&:MW FRS for reactions shown;.Lumber DOL=1.60 plate grip
DOL=1.60
3) All plates are MT20 plates unless:otherwise iridicated... "
4) .This truss has been designed.for a 10.0 psf bottom chord, live load nonconcurrent with any.other live loads.
5) *. This truss has been.designed for a live load of 20.Opsf on the -bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and, any othbr members, with BCDL = 10:Opsf:
6) All bearings are assumed to be SYP"No.2 crushing capacity of 565 psi:
7) Bearing at joint(s) 2, 8 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.. .:.
8) Provide mechanical connection (by others) of truss. to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb)
2=906, 8=906.. ... .:
9) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top Chord and 1/2" gypsum::
Thomas A: Alban) PE No.39380
ThoMiTem
i E N6.634
sheetrock be applied directly to the bottom chord:
USA, Inc.
6904 Parke East Blvd. Tampa FL 33610 . .
Date: .
..February 20,2020
0 :WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 101=015 BEFORE USE
Design valid for use only with MIT" connectors. This design is based only upon parameters shown• and is for an individual building component, not
�"
o.truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into. The overall
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing..
MiTek'
is always:required: for stability and to prevent collapse with possible personal Injury and:property damage. For general guidance regarding the : ...
. .
fabrication; storage, delivery, erection and bracing of trusses and truss systems, seeANSViPl1 Quality CrBorla, DSB-89 and SCSI Bullding Componont' .
6904 Parke East Blvd.
Safety Informatlonavoilable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Csty.
Ply
LOT 32/1 WATERSTONE
T19470845
2254612
A04A. .
Roof Special
1
1.
Job Reference (optional)
ounue,b rnstavun:e tnant ytty, rL); rant tiny, rL - :1000f, .. _ . _ _ tf.z4U S re[) r zyzu mi i eK mausines inc. I nu reD zu 11:1 b:b2 2UPU rage 1
ID:v3HtyczpYvZl l m7gXrhK6yOc4g-xZl efz38Uj 1 BgD7ZYrBcGHGvG_CxW 6dtovfzBnzjG5v
:.r1-4-0, 6-7-10 8-8-0 12-9-13 .18-4-0 19-Or0 22-2-0 - 29-4-0 31-4-6 , 38-0-0 a9-4-9
1-4-0' 6-7-10 2-0.6" 4-1-13 5=6-3 8- 3-2-0 7-2-0 2-0-6 . 6-7-10 1=4.0
Scale =.1:72.2
8x14 MT20HS I
... 6.00 F12 ... ..
2x4 I
.. 6 7
3x4II .. ..
.. .. 5x6' i 27 8 28 .: .. .. .. .. .
3x6 i .. 5x6 J
. .. 2x4 4 6 15 9 2x4 i .. .
.. SPir10 = .. to
26
1.5x8 STP = .
� 2
eI 1
0
0
29 ur
_ 11Im
.. .. ... .. .. ..
:' ..'.:. 5x8'G .:.MO 12 .. .. ...
.. .. ..
..
5x8 Z
..
8-8-0 12-9-13 18-4-0 22-2-0 - 29.4-0
38-0.0
8.8-0 . 4-1-13 5=6-3 3.1070 7-2-0
8-8-0
Plate Offsets (X,Y)-- [2:0-2-7,Edge],[5:0-3-0,0-3-0]„[7:0-•1-12;Edge], [9:0-2-12,0-3-0], [11:02,7;Edge], [13:0-7-8,Edge], [15:0-3-4,0-4-0], [16:0-2-8,0-3-12]; [18:0-1-12,0-3-0], . .
[19:0-4-0,Edgel
LOADING (psf)
SPACING- _ 2=0-0
CSI.
DEFL. in (loc) I/defl Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL. 1.25
TC. : 0.93
Vert(LL) : .. 0.66 15-16 >459 240:.
MT20 244/190
TCDL .. .7.0 ..
Lumber DOL 1.25
BC . 0.91
Vert(CT). . -1.29 15-16 >353 180
MT20HS .. 187/143
BOLL0.0 *
Rep.Stress Incr YES
WB 0.98
Horz(CT) 0.91 :11: n/a. ' n/a
BCDL. 10.0
Code FBC2017/TPI2014
Matrix -AS
Weight: 229 lb FT = 20%
LUMBER- BRACING;
TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly
applied.
BOT CHORD 2x4 SP No.2 *Except* BOT CHORD Rigid ceiling directly applied. '
2-19,11-13: 2x4:SP No.1, 6-17,8-14: 2x4 SP N6.3, 15-16: 2x6 SP No',2 WEBS 1 Row at m[dot 13-15,
WEBS 2x4 SP N6.3 *Except*
16-18;13-15: 2x4 SP No.2 "
WEDGE.
Left: 2x4 SP No.3, Right: 2x4 SP No.3'. .
REACTIONS. (lb/size) . 2=1478/0-8-0, 11=1478/0-8-0 : ..
Max Harz 2=418(4C 11)
Max Uplift 2=-906(LC 12),:11=-90%LC 12)
FORCES. (lb) - Max. Comp./Max, Ten. - All forces.250 (lb) or less except when'shown.
TOP. CHORD 2-3=4603/27.12, 3-4= 4395/2585, 4-5= 307.1/1900, 5-6=-3740/2091, 6-7=73615%2156,
7-8=-5092/2964, 8-9= 5202/2826, 9710=-4440/2604, 10-11=-4604/2682
BOT CHORD 2-19=-2278/4352,'18-19=-1953/3998, 6-16=-85/321, 15-16=-1121/2989, 8-15=-280/407. ..
11-13=-2299/4149
WEBS 4-19= 574/1209, 4-1 8=- 1441/780, 5-18=-717/370, 16-18==1474/3140, 5-16=-14/594,:
7-16=-1037/1684,.13.15=-2277/4302, 9-15=7196/784, 9-13=-610/399, 7-15— 1544/2581,
3-19=-167/250
NOTES- .. . . .. . .
1) Unbalanced_ "roof live loads have beer, considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3=second gust) Vasd=124mph; TCDL=4.2psf; BCDL=6.Opsf; h=25ft; B=45ft; L=40ft; eave=6ft; Cat.
II;: Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-4-0 to 2-8-0,.lnterior(1) 2-8-0 to 19-6-0,.Exterior(2) 19-0-0 to
23-0-0, Interior(1) 23-0-0 to.39-4-0 zone;C-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip
DQL=1.60
3) All plates: are, MT.20 plates unless otherwise indicated.
4) This truss "has been designed for a 10.0 psi bottom chord live load nonboncurrent with any other live loads..
5) * This truss has been designed for alive load of 20.Opsf on the bottom'chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members...'
61 All bearings are assumed to be SYP No.2 crushing capacity of 565 psi.
7) Bearing at joint(s).2,-11 considers parallel to. grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
Thomas ArAlbani PE N6.39380
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 Ib uplift at•joint(s) except at=lb) .
Mirek USA, Inc. FL Cert'6634
2=906, 11=906.
9) This truss design requires.that a minimum of 7/16"structural wood sheathing be applied directly to the top chord and,1/2" gypsum
6604 Parke East Blvd. Tampa FL 33610
sheetrock be applied directly to the bottom chord.
Date:
. February 20,2020 .
0 WARNING -Verify design paramefers and READ NOTES ON THIS AND INCLUDED WEK REFERANCE PAGE M/F7473 rev. 1010312015 BEFORE USE.
Design valid for use only.wlth MITek® connectors. This design Is based only upon parameters shown and is for an Individual building component, not
o.truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design, Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing .
MITek'
Is always:required. for stability and to prevent' collapse with possible personal Injury and: property damage. For general guidance regarding the: ..
. .
fabrication, storage, delivery, erection and bracing of trusses and truss systems,'seeANSVWII CualH�y Cdtedo,"DSB49 and BCSI Bullding Component:
6904 Parke East Blvd..
Safety Informatloncivailable from Truss Plate Institute, 2.18 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss a
Truss Type
C�ty.
Ply
LOT 32/1'WATERSTONE
+
T19470846
2254612
A05 '
Roof Special
1
1.
Job Reference optional)
ouiwota n.awuw ue tnant l 11y, rL/t rtnnt i,ny, rt_ - 0o001, o.44u s reo f Zllzll Mi I eK inousines, Inc. I nu reD zu 1 in ti:b3 zuzu rage 1
Z11r g rh y 092SNII6 p zl 5u
ID•v3HtyczpYv n? X K6 Oc4g-OIbOtJ4nF Zir Up4tNXmFaP01ZPXjE 'G
-7-10 12-9-1318-8-0 19 - 25-2-3 31-4-69-4-
.. 62-3 .. 5-10-3 0-4- S-10-3 .. ... 6-2-3 "'
. 6-7-10 1-4-0
.. .. ..
. ... .. ... 04_0 ..
..
Scale = 1:73.6
6x12:MT20HS = .
6.60 F12
5
Sx8 i 5x B ... .. ... .. ... ..
.: .
236
4 .
2x4 -Z�_
2x4 i
3:
7
1.5x8 STP =
21
24
1.5x8 STP = ..
14 ..25..
O
m 2 '.. 13.. 12 11 . 10
1
�i9.
B 9 Iv 1
6xl2 MT20HS =
o' 3x4 = 3x6 = 3x4'= 6x12 MT20HS=
d
5x8� •.. 3.00 12 .. ..
.. ... 5x8 �. .. .
8-8-0 15-6-13 22-5-3 29-4-0
38-0.0
8-8-0. 6-10.13 6-10-6 6.10.13
8-8-0
Plate Offsets -- 2:0-2-7,Edge], 4:0-4-0,0-3-01, [6:0-4-0 0-3-0], [8:0-2-7,Edge] . .
LOADING (psf)
SPACING- 2-0=0
CSI.
DEFL. in ([go). I/deft Lid
PLATES. GRIP
TCLL 20.0 :
Plate Grip DOL 1.25
TC 0:94 :
Vert(LL) 0.73 13-14 >623 240
MT20 244/190
TCDL7.0
Lumber DOL :. 1.25
BC:' :.0:94
Vert(CT)' -0.9413-14 >486 180:.
MT20HS 187/143
BCLL 0.0 '.
Rep Stress Incr YES
WB . 0.89
Horz(CT) 0.69 8 n/a n/a.
BCDL 10.0
Code FBC2017ITP12014:
Matrix -AS
..
Weight:192 lb FT = 20%
LUMBER- BRACING-
.. .
TOP CHORD 2x4.:SP No.2 TOP CHORD - Structural wood sheathing directly applied.
BOT CHORb 2x4 SP No.2 `Except' BOT CHORD Rigid ceiling directly applied.
2-14,8-10: 2x4 SP No.i
WEBS 2.4 SP No.3.
WEDGE
Left: 2z4 SP, Na.3, Right: 2x4 SP No:3, ..
REACTIONS. (lb/size) 2=1478/0-8.0, 8=1478/0-8-0
Max Horz 2=415(LC t 1)
Max Uplift 2=-906(LC 12), 8=-906(LC 12) . "
FORCES. (Ib) - Max. Comp./Max. Ten. - All forces250 (lb) or less except when:shown.
TOP CHORD: "2-3=-4726/2812, 3-4=-4432/2626, 4-5=-2557/1748, 5-6=-2557/1754, 6-7=-4360/2648,'
7-8=-4651/2820
BOT CHORD 2-14=-2385/4569,.13-14=-1406/2925, 11-13=-725/1868, 10-11=-1440/2722,
8-10=72429/4197
WEBS 5-11=-670/1133, 6-11=-970/810, 6-10=887/1677, 7-10= 310/386, 5-13=-665/1195,
4-1 3=- 1037/805, 4-14=-881/1831, 3-14=-298/385
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160rriph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=6.Opsf; h=25ft; B=45ft; L=40ft; eave=6ft; Cat.
II; Exp.C;, Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-4-0 to_2-8-0, Interiot(1) 2-8-0 to 19-0.0, Exterior(2) 19-0-0 to
24-7-14, Intetior(1) 24-7-14 to 39-4-0 zone;C-Cfor members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate
grip DOL=1.60
3) All plates are MT20 plates unless:otherwise indicated... p
4) .This truss has been designed fora 10.0 psf bottom chord live load nonconcurrent with any. other live loads.
5) '. This truss has been:designed for a live load of 20.Opsf on the bottom chord in all: areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and. any other:rriembers, with BCD = 10;Opsf:
6) All bearings ate. assumed to be SYP No:2 crushing capacity of 565 psi::
71 Bearing at joint(s) ' 2, 8 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify '
capacity of bearing surface...
81 Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb)
2=906, 8=906•. .. ..
9) This truss design requires that a minimum of7/16" structural wood sheathing: be applied directly to the top chord and 1/2" gypsum:,:
Thomas A Albani PE No.38360
E N
sheetrock be applied directly to the bottom chord.ThomMiTek
.393
i
USA, Inc. 6634
6804 Parke East Blvd. Tampa FL 33610 .:.
Date:
February 20,2020.
:WARNING -Verity design parameters and READ NOTES ON THIS AND INCLUDED MTTEK REFERANCE PAGE M11-7473 rev, 1010312015 BEFORE USE
"
Design valid for use only. w.iTh MiTekC� connectors, This design is based only upon parameters shown, and is for an Individual bullding component, not
a, truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
-
building design, Bracing indicated is To prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing .
MiTek'
is alwayssequired. for stability and to prevent collapse with possible personal Injury.and.property damage. For general guidance regarding the : . .
fabrication; storage, delivery, erection and bracing of trusses and truss systems, seeANSVIPI1 Quality Cdtedo, DSB-69 and SCSI BuadNp Component..
6904 Parke East Blvd.
Safety Informationdvoilable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL .33610
Job
Truss
Truss Type
guy
Ply
LOT 32/1WATERSTONE
+
T19470847
2254612
A06
Hip
1
1
Job Reference o tional
warn �.,ny, rL - 00001,
tl.z4U S r•eo / zUzu MI I eK Inousines, nc. I nu reD zu 11:16:b4 2U'LU rage 1
ID:v3HtyczpYvZl 1 m?gXrhK6yOc4g-ux9O4f5POKHv3 W HxgGD4LiLEBnt0_4YAGD84FgzjG5t
r1-4-0 6-7-10 12-9-13
16-t3-0
21-4-0 25-2-3 31-4-6 38-0-0 a9-4-q
1-4-0 6-7-10 6-2-3
3-10-3 .
4-8-0 SIMN 6-2-3 6-7-10 1-4'-0
Scale = 1:70.8
6.00, 12 5xe =
5x6 =.
s
6".
5x6 i
5x6
4
7
23
24
w
-
.. 2x4 Q
2x4 G�
3
8
1:Sx8 STP =
22
.25
1.5xB STP=
15
2
14
12 o
13 11 0
1 6x8 = -
3x8 = silo Iv N
0
4x6.= 5x6 = 0
3x4 =
5x83.00 :12
8-8-0
16-8-0
21-4-0 29-4-0 38-0-0
8-8-0
8-0-0
4-B.0 8-0-0 B-8-0
Plate Offsets (X,Y)-- [2:0-2-7,Edge1, [4:0-3-0,0-3-01, [5:0-6-0,0-2-81,[6:0-3-0,0-2-01,.[7:03-0,0-.3-01, [9:0-2-7,Edgel, [11:0-2-12,0-3-4], [15:0-4-0 Edge]
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in (lac). I/deft Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.97
Vert(LL) 0.74 14-15 >616 240
MT20 244/190
TCDL 7.0
LumberDOL 1.25
BC: 0:93
Vert(CT):'.-1.0214-15 >446 18b.
BCLL 0.0 '
Rep Stress Incr YES
WB 0.70,
Horz(CT) 0.59" 9 n/a n/a.
BCOL 10.0
Codea, FBC2017/TPI2014
Matrix -AS
Weighty 199 lb FT = 20%
LUMBER-
BRACING-
TOP CHORD 2x4 SP No.2
pTOP
CHORD Structural wood sheathing directly applied.
BOT CHORD 2x4 SP No.2 *Except*
BOT CHORD Rigid ceiling directly applied.
2-15,9-11: 2x4 SP No.1
WEBS 2x4 SP No.3
WEDGE
Left: 2x4 SP No.3, Right: 2x4 SP No.3
"
REACTIONS. (lb/size) 2=1478/0-8-01,9=1478/0-8-0
Max Harz 2= 371(LC 10)
Max Uplift 2=7906(LC 12), 9=-906(LC 12)
OuI LINUMU Z-Ia=-Za`J`J/4Ja /',.14-1b=-1 b4U/Z /'L`J, l'L-14=-`JtSb/LU/b, 71-1'L— 1'J/lLG69`J; .:
9-11= 2638/4213
WEBS 3-15=-319/398, 4=15=-947/1830, 4-14— 1034/837, 5-14= 550/897, 6-12=-519/833,
7-12=-968/841, 7-11==958/1717; 8-11=-331/398
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=6.Opsf; h=25ft; B=45ft; L=40ft;
II; Exp,C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2),-1-4-0 to 2-8-0, Interior(1) 2-8-0 to 16-8-0, Exter
26-11-14; Interior(1) 26-11-14 to 39-470;zone;C-C for members and forces'&' MWFRS for reactions shown; Lumber D(
grip DOL=1.60
3) Provide adequate drainage to'prevent water ponding. .
4) .This truss has been designed.for a 10.0 psf bottom chord live load nonconcurrent with any. other live loads.
5) ' This truss has been:designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall b
will fit between the bottom chord andany other:niembers. - .
6) All bearings are assumed to be SYP"" No.2 crushing capacity of 56S psi.
7) Bearing at joint(s) 2, 9 considers parallel to grain value using ANSVTPI 1 angle.to grain formula. Building designer shy
capacity of bearing surface. "
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) e'xci
2=906, 9=906.
9) This truss design requires that a minimum of 7/16" structural woodsheathingbe' applied directly to the top chord and 1
sheetrock be applied directly to the bottom chord.
1; Cat.
8-0 to
:)late
ride
y
Im Thomas A. Alban! PE N6.39380
MiTek USA, Inc. FL Cart 6634
6604 Parke East Blvd. Tampa FL 33610
Date:
February 20,2020
O:WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MMEK REFERANCE PAGE M167473 rev. f0/03F20f5 BEFORE USE,
Design valid for use anty.wlth MiTek® connectors. This deslgn Is based only upon parameters shown, and is for an Individual bull ding Component, not
a, truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design, Bracing indicated is to prevent buckling of Individual Truss web and/or chord members only. Additional temporary and permanent bracing
T
MOW
Is alwayssequired. for stability and to prevent collapse with possible personal Injury and:property damage. For general guidance regarding the:
fabrication; storage, delivery, erection and bracing of trusses and truss systems, seeANSV711 Quality Criteria, DSB-89 and SCSI Buadtng Component .
6904 Parke East Blvd.
Saliety, Infmrnationovallable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Q}y.
Ply
LOT 32/1 WATERSTONE
a
T19470848
2254612
A07
Hip
1
1
Job Reference (optional)
. . ouuaers nrstouurce triani Lrry, rLl, - riani t,iry, rL - 0000r,
6-7-10 6-2-3
2x4
3 /.
23
1.5x8 STP
m 2
�1
0
6.00 12
tl.z4u s reD i zuzu MI i eK mausineS,.inc. I nu reD zu 11 in b:bb zuzu rage 1
ID:v3HtvczDYvZ11 m?aXrhK6vOc4a-aKG9VL6fYxXcJoRKnhGYQ7RaMbZFSzISiXdBKZziG5i
1-10-3 ' 4-4-0 4-4-0 '1-10-3 '
5x6
5x6 i S
4
3x4 = 5x6 =
25 6 26 7
Scale = 1:70.8
5x8 :r- 3.00 .12 -'. ...
.
B-8-0 14•B-0 23-4-0 29-4-0
38-0-0
8-8-0 6-0.0 8-8-0 6.0-0
B-8-0
Plate Offsets (X,Y)-- [2:0-2-7,Edge], [4:0-3-0,0-3-4], [5:0-3-0,0-2-01, [7:0-3-0,0-2-0], [8:0-3-0;0-3-4], [10:0-2-7,Edge]
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc). Vdefl Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0,99
Vert(ILL) 0.73 15-16 >627 240
MT20 2441190
TCDL 7.0
Lumber DOL 1.25
BC: ..0.95
Vert(CT) -0.95 13-15 >480 180
MT20HS 187/143
BCLL 0.0
Rep Stress Incr YES
WB . 0.75
Horz(CT) 0.60 10 n/a n/a
BCDL 10.0
Code. FBC2017ITP12014
Matrix -AS
Weight::200 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied.
BOT CHORD 2x4 SP No.2 'Except . BOT CHORD Rigid ceiling directly applied.
2-16,10-12: 2x4.SP No.1
WEBS 2x4 SP No.3
WEDGE
Left: 2x4 SP No.3, Right: 2x4 SP No.-3_
REACTIONS. (lb/size) 2=1478/0-8-0, 10=147810-8-0
Max Horz 2=-330(LC 10)
Max Uplift 2=7906(LC 12), 10=-906(LC 12)
FORCES. _(Ib) - Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD- 273=-4656/3145, 3-4=4353/2941, 4-5=-2683/2019, 5-6==2874/1812, 6-7=-2374/1821-1
7-8=-2683/2028, 8-9=-4353/2961, 9-10=-4653/3165" .
BOT CHORD 2-16=-2707/4442;.15-16=-1571/2814; 13-15=-1358/2474, 12-13=-1602/2718,:.
10-12=-2746/4200
WEBS 3-16=-323/416, 4=16=-1018/1782, 4-15-=968/857, 5-15--826/1099,'6=15=-304/272,
6-13=-304/272, 7-13= 83O/1099; 8-13=-913/862, 8=12- 1030/1666, 9-12=-333/415
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph.(3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=6.Opsf; h=25ft; B=45ft; L=40ft; eave=6ft; Cat.
II; Exp.C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2)-71-4-0 to:2=8-0, Interior(1) 2-8-0 to 14-8-0,-Exterior(2) 14-8-0 to
20-3-14, Interior(1) 20-3-14 to 23-4-0, Exterior(2) 23-4-0 to 28-11-14, Interior(1) 28-11-14 to 39-4-0 zone;C-C for members and
forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to:prevent water ponding.
4) All plates are MT20 plates: unless otherwise indicated.. .
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurreni with any other live loads.
6) *This truss has been designed for alive load of 20.Opsf on the bottom chord in all areas where a rectangle 3=6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = I O.Opsf.
7) All bearings are assumed to be SYP No.2 crushing capacity of 565 psi.
8) Bearing at joint(s) 2,'10 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface: .
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=1b)
2=906; 10—_W&
Thomas A. Albani PE N6.39380
10) This truss design requires that a minimum of-7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum,
MiTek USA, Inc. FL Cert 6634
sheetrock be applied directly to the bottom chord.
6904 Parke East Blvd. Tampa FL 33610
Date:
February 20,2020
WARNING - Verify desl n arameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PA' E.MII-7 73 v. 1 0 5 BEFORE
.Q y g .p G 4 re W 3l ci USE
Design valid for use only with MlTelc®connectors. This design is based only upon parameters shown, and is for an individual building Component, not
building
Nit
o.truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into. the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
Is always required for stability and to prevent collapse with possible personal Injury and:property damage. For general guidance regarding the:
fabrication, storage, delivery, erection and bracing of trusses and truss systems,'seeANSVTpil Qual9Syy Criteria. DSB-89 and BCSI BuBding Component'
Safety Infonnatlonavailable from Truss Plate Institute. 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
M iTek'
6904 Parke'East Blvd.
Tampa, FL 33610
Job
Truss pTruss
Type i
O;y.
Ply
LOT 32/1 WATERS TONE
T19470849
2254612
A08
Hip
1
1
Job Reference (optional)
oun r --u— tr and —Ly, rLl-,
r—., -Ly, -- JJUD/,
D.G4U 5 reU / ZUZU IVII I UK If1UU5111U5,:If1G. I flu reu zU I I:ID:D/ euzu rage 1
ID:v3HtyczpYvZl l m?gXrhK6yOc4g-I WgXih7HJFfrw_OW LPnnzKZlx?v5BSScyBNks?zjG5q
r1-4-0, 6-7-10
8-8-0 12-8-0
19-0-0
25-4-0 29-4-0 31-4-6 38-0-0 39-4-q
1-4-0 6-7-10
2-0-6 4.0-0
6-4-0 '.
6-4-0 4-0-0 2-0.6 6-7-10 1-4-0
Scale = 1:68.9
5x6 =
3x8 =
5x6 =
26
:27:28
29 7
6.00 12
3x6
3x6
.4
8 2x4 5-
2x4
30
m
3.25
9
v.
cc
24
31
1.5x8 STP=
1.5x8 STP=
17 16
14
13 12 O
1.1 2
6x8 = 5xB =
15
4x6 — 2x4 11
0
5x8 = 6x8 = 10 1? c�
Io
11
Sx8
SirB 3.00 12
B-B-0 12-8-0 19.0-0 25-4.0 29-4-0 38-0-0
8-8-0 4-0.0 6-4-0 6-4-0 4-0-0 8.8-0
Wets (X,Y)-- [2:0-2-7,Edge], [5:0-3-0,0-2-0], [7:0-3-0;0-2-0], [10:0-2-7,Edge], [12:0-4-0,Edge], [17:0-4-0,Edge]
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc), I/defl Ud
PLATES. GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 1:00 "
Vert(LL) 0.73 : 14 >628 240
MT20-244/190
TCDL 7.0
Lumber DOL 1.25
BC.. 0:91
Vert(CT) -0.92 14-16 >494 180
BCLL 0.0 '.
Rep Stress Incr YES
WB . 0.63
Horz(CT) 0.60 . 10 n/a n/a.
BCDL 10.0
Code. FBC2017rrP12014
Matrix -AS
Weight: 193 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.2 TOP CHORD . Structural wood sheathing directly applied.
BOT CHORb' 2x4 SP No.2 'Except' . BOT CHORD Rigid ceiling directly applied.
2-11,10-12: 2x4 SP No.i
WEBS 2x4 SP No.3.
WEDGE
Left: 2k4 SP No.3, Right: 2x4 SP No:3
REACTIONS. (lb/size) 2=1478/0-8=0, 10=1478/0-8-0
Max Harz 2=-289(LC 10)
Max Uplift 2=7906(LC 12), 10=-906(LC 12)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown.
TOP CHORD 2-3=-4602/3141, 3-4=-4393/3035, 4-5=-3057/2184, 5-6==2741/2055, 6-7=-2741/2065,
7-8=-3057/2196, 8-9=-4393/3055, 9-10=-4602/3161
BOT CHORD 2-17=-2696/4216,.16-17=-2387/3868; 14-16=-1176/3088, 13-14=-1776/3088,
12-13=-2426/3860, 10-12=-2735/4148
WEBS 4-17=-647/1173, 4-16=-1429/.1024, 516=-652/1084, 6-16=-579/367, 6-14=0/260,
6-13=-579/367, 7-13=-657/1084, 8-13=-1354/1033, 8-12=-655/1118
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=6.Opsf; h=25ft; 6=45ft; L=40ft; eave=6ft; Cat.
ll; Exp,C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2).-1-4-0 to:2=8-0, Interior(1) 2-8-0 to 12r8-0, Exterior(2) 12-8-0 to
18-3-14, Intedor(1) 18-3-14 to 25-4-0, Exterior(2) 25-4-0 to 30-11-14, Interior(1) 30-11-14 to 39-4-0 zone;C=C for members and
forces & MWFRS for reactions shown; Lumber.DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to:prevent water ponding.
4) This truss has been designed.for a 10.0 psf bottom chord.live load nonconcurrent with any other live loads.
5) ° This truss has been designed fog a live load of 20.Opsf on the bottom chord in all: areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between th6 bottom chord and any other members.
6) All bearings are, assumed to be SYP No.2 crushing capacity of 565 psi:
7) Bearing 'at joint(s)' 2, 10 considers parallel to grain value using ANSI/LPI 1 angle to grain formula: Building designer should verify
capacity of bearing surface.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except at=lb)
2=906, 10=906.
9) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum.
Thomas A. Albani PE No.38380
sheetrock be applied directly to the bottom chord.
MTek USA, Inc. FL Nrt 6634
69D4 Parke East Blvd. Tampa FL 33610
Date:
..February 20,2020
WARNING - Verif desl n arameters and READ NOTES ON -
y g p THIS MREK REFERANCE PAGE Mll7973 rev, fo/o3/2015 BEFORE USE
Design valid for use only, with MITek® connectors, This design Is based only upon parameters shown, and Is for an individual building component, not
a.truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing .
Is alwayssequired for stability and to prevent collapse with possible personal Injury ond:properfy damage. For general guidance regarding the .
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSVrPII Quality Cdteda, DSB-89 and SCSI Building Component
Safety Infonnatlonavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
��-
A
MOW
6904 Parke East Blvd..
Tampa, FL 33610
Job
Truss
Truss Type
Q;y
Ply
LOT 32/1 WATERSTONE
4
T19470B50
2254612
A09
Hip_
1
1
Job Reference (optional)
ouuaers mrstoaurce trlani ldiy, rLJ; riam lily, rL - JJbbf, b.z4u S reD / zuzu mi I eK Inausmes, Inc. I nu reD zu 1 in tj:bb zuzu rage 1
I D:v3HtyczpYvZl l m?gXrhK6yOc4g-miOvwl 8v4ZnKYBbjv610W YW yBOEOwuz1Br6lORzjG5p
r1-4-0, 6-7-10 81 10-8-0 16-2-11 21-9-5 27-4-0 29-4-0 31-4-6 38-0-0 a9-4-q
1-4-0 6-7-10 2-0-6 2-0-0 5.6-ti 5.6-11 5-6-11 2-0.0 2.0-6 6-7-10 1-4-0
Scale = 1:68.9
5x6 =
2x4 I �5
6.00 12
3
24
1.5x8 STP = 23
co
01 2
5x8 % 3.00 F12
16 15
6xB = 3x4 =
3x4 = 5x6 = 5x6 =
26 5 6 27 �28 3x6
8.
14 13 12 -it "
3x8 MT20HS = 3x8 = 6k8 =
3x4
m
ao
29 m
30
1.5x8STP= o
0
g 10 T N
Io
5xB
8-8-0 10.8.0 19.6-0 27-4-0 29-4-0
38-0-0
8.8-0 0 8-4-0 8-4-0 2.0.0
8-8-0
Plate Offsets (X,Y)-- [2:0-2-7,Edge], [4:0-3-0,0-2-01, [6:0-3-0,0-3-01,[7:0-3-0,0-2-01,-[9:0-2-7,Edgel, rl1:0-4-0,Edge], [16:0-4-O,Edgel
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc), I/defl Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.84
Vert(LL) 0.78 13 >585 240
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC . 0.99
Vert(CT) -1.04 12-13 >440 180'
MT20HS 167/143
BCLL 0.0
Rep Stress ]nor YES
WB 0.67
Horz(CT) . 0.61 9 n/a n/a
BCDL 10.0
Code. FBC2017/TP12014
Matrix -AS
Weight: 182 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4'SP No.1 *Except* TOP CHORD. Structural wood sheathing directly applied.
4-6,6-7: 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied.
BOT CHORD 2x4 SP No.1 *Except*
14-16,11-14: 2x4 SP No.2
WEBS 2x4 SP No.3
WEDGE
Left: 2x4 SP No.3, Right: 2x4 SP No.3
REACTIONS. (lb/size) 2=1478/0-8-0, 9=1478/0-8,0
Max Horz 2=247(LC 11)
Max Uplift 2=-906(LC 12), 9= 906(LC 12)
FORCES.- (lb) = Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 23=-4546/3088, 3-4==4444/3306, 4-5=-3238/2328, 5-6=3931/2737, 6-7=-3237/2339, .
7-8= 3587/2590, 8-9= 4539/3095
BOT CHORD 2-16=-2623/4089, 15-16=-1860/3214, 13-15= 2339/3863, 12-13= 2351/3863,
l l-12=-2523/3892, 9-11=-2647/40B2
WEBS 3-16=-328/535, 4-16=-1258/1553, 4-15=-302/611, 5-15=-845/638, 6-12=-843/639,
7-12=-1054/1426, 8-12=-1174/1052, 8-11=-564/1005'
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10;:Vdlt=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; B=45ft; L=40ft; eave=6ft; Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS .(directional) and C-C Exterior(2) -14-0 to 2-8-0, Interior(1) 2-8=0 to 10-8-0, Exterior(2) 10-8-0 to
16-2-11, Interior(1) 16-2-11 to 274-0, Exterior(2) 27-4-0 to 32-11-14, Interior(1) 32-11-14 to 39-4-0 zone;C-C for members and
forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 "
3) Provide adequate drainage to prevent water ponding. . . .
4) All plates are MT20 plates unless otherwise indicated.
5) This truss has been designed for a 10.0 psf. bottom chord live load nonconcurrent with any other live loads. .
6) *This truss has been designed for a live' load of 20.Opsf on the bottorn chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide '
will fit between the bottom chord and any other members.
7) All, bearings are assumed to be SYP No.2 crushing capacity of 565 psi.
8) Bearing at joint(s) 2, 9 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface. .. ...
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joints) except Qt=lb) Thomas A Albani PE No.39380
2=906, 9=906. M[Tek USA, Inc. FL Cert 6634
10) This truss design requires that.a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2 gypsum 6904 Parke East Blvd, Tampa FL' 33610 .
sheetrock be applied directly to the bottom chord. Date:
February20,2020
Q WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MIiEK REFERANCE PAGE 111II-7473 rev. 10/0=2015 BEFORE USE.
Design valid for use only. with MITek® connectors, This design Is based only upon parameters shown, and is for an Individual bull ding component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek"
Is always:required for stability and to prevent collapse with possible personal Injuryand:property damage. For general guidance regarding The .
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSVMII Quality Criteria, DSB49 and SCSI Buading Component.
6904 Parke East Blvd.
Safety Informatbnovalloble from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
O)y
Ply
LOT 32/1 WATERSTONE
r
T19470851
2254612
A10
HIP GIRDER
1
3
Job Reference (optional)
ounueia niaiouurco lnaui uuy, 11), nar Il any, r'L - 00001, 8.-e'W 5 rep I ZUZU rill I eK InaU5Ine5, Inc. I nu rep ev l l:l t:uu zueu rage i
l m?gXrhK6yOc4g-i5W gL3j9AbAl2nRk5OXKUbzbRtC2sOpr2e8bOTKzj G5n
1 3-10-44-0, 114 12ID:v-3HtyczpYvZl
4-112 0 3-5-5
689-0-0 48r1-4
4-
3-0-0
-
4
'
Scale=.1:68.9
7x10 2x4 II 7k10 = 2x4
6.00 12 4 26 27 28 529 30 , 31 6 32 33 734 35 36 37 8 7x10
3x4 G
3x4
m
3
9
N
44
1.5x8 STP =
1.5x8 STP =
18 17 15 14 13 .
2 38 39 _ 4016 41 42 43 44 45
10
IN
5x8 =
01 6x12.MT20HS- 2x4 I 5xB = 6xB =
m
11 Ia
19
12 6
2x4 11 5x8 =
2x4 11
5x8 3.00 12
5x8 zz
4-6-11 8.8-0 12.10-14 19-0-0 24-1-2 29-4-0 33-5-5
38-0-0
4-6-11 5-2-14 5.1-2 5-1-2 5-2-14 4-1-5
4-6-11
Plate Offsets (X,Y)-- [4:0-1-12;Edge], [6:0-5-0,0-4-81, [13:0-2-8,0-1-81, [18:0-6-4,0-3-01
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc)" Vdefl Ud
PLATES GRIP
TCLL 20.0 - -
Plate Grip DOL 1.25
TC 0.31
Vert(LL) 0.89 15 >513 240
_
MT20-244/190
TCDL 7.0
Lumber DOL ' . 1.25
BC . 0.39
Vert(CT). -0.89 15 >514 180.
MT20HS 187/143
BCLL 0.0
Rep Stress Incr NO
WB 0.59
Horz(CT) 0.44 10 n/a n/a
BCD.L 10.0
Code FBC2017/TPI2014
Matrix -MS
Weight::693 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP M 31 'Except' TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
4-6,6-8: 2x6 SP M 26 BOT CHORD Rigid ceiling directly applied or
10-0-0 oc bracing.
BOT CHORD 2x6 SP M 26
WEBS 2x4 SP No. 3
REACTIONS. (lb/size) 2=3840/0-870, 10=384010-8-0
Max Horz 2=206(LC 7)'
Max Uplift 2= 2857(LC 8), 10=-2857(LC 8)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. .
TOP CHORD 2-3=-13431/9713, 3-4=-14630/10718, 4-5_ 16973/12533, 5-6=-16970/12530',
6-7=-16970/12530, 7-8=716974/12533, 8-9=-14630/10719, 9-10— 13431/9713
BOT CHORD 2-19=-8684/12193, 18-19=-8818/12369, 17-18=-9331/13080, 15-17= 13218/18313,
14-15=-13218/18313,.13-14=-9332/13080, 12-13=-8818/12369; 10-12=-8684/12193
WEBS 3-19=-651/598, 3-18=-1327/1385, 4-18=-3358/4613, 4-17= 3157/4351, 5-17=-606/353,
6-17=-1555/1143, 6-15=-613/642, 6-14=-1555/1144, 7-14=-606/354; 8-14=-3158/4351,
8-13=-3358/4613, 9-13=-1356/1385, 9-12= 651/598
NOTES-
1) &ply truss to be connected together with 10d (0.131 "x3") nails as follows:
Top chords connected as follows: 2x4 -1 row at 0-7-0 oc, 2x6.2 rows staggered at Or9-0. oc.
Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc.
Webs connected as follows: 2x4 - 1. row at 0-9-0 00, Except member 18-4 2x4 - 1 -row at 0-7-0 oc, member 13-8 2x4 - 1 row at 0-770
oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD_ CASE(S) section. Ply to
ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Unbalanced roof live loads have been considered for this design.
4) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=6.Opsf; h=25ft; B=45ft; L=40ft; eave=6ft; Cat.
ll; Exp;C;,Encl.;,GCpi=0.18; MWFRS (directional); Lumber DOL=1.60:plate g(ip DOL=1.60
5) Provide adequate drainage to prevent water ponding.
6) All plates are MT20 plates unless otherwise indicated.
7) This truss has been designed fora 10.0 psf bottom chord live load nonconcurrent with any other live loads.
81 ' This truss has been designed for a live load of 20.0ps'f on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
9) All bearings are assumed to be SYP'No2 crushing capacity of 565 psi.
Thomas A Albani PE N6.38380
10) Bearing at joint(s) 2, 10 considers parallel to grain value using ANSVTPI 1"angle to grain formula. Building designer should verify
MiTe k USA, Inc. FL Cert6634
MiTeParke
capacity of bearing surface. - -
11) Provide mechanical connection -(by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except at=lb)
East Blvd. Tampa FL 33610'
2=2857, 10=2857.
Date:
February 20,2020
0 WARNING -Verify deslgn parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MI1-7473 rev. 1010312015 BEFORE USE:
'
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing indicated isto prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
Mffek'
Is always required for stability and to prevent collapse with possible personal lnjury.and:property damage. For general guidance regarding the:
fabrication; storage, delivery, erection and bracing of trusses and truss systems, seeANSVTP11 Quality Criteria,'DSB-89 and BCSI BuOdIng Component'
6904 Parke'East Blvd.
Safety Informatlorrovaliable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
qty
Ply
LOT 32/1 WATERSTONE
T19470851
2254612
A10
HIP GIRDER
1
3
Job Reference o tional
ouuueia rnswuwue innnl tidy, ru/, MUnl Uiry, rL - 30Do/, 7j.z4u S rep 12U2u MI I eK Inaustnes,:inc. I nu he0 2u 11:1 /:uu 2uzu- rage 2
ID:v3HtyczpYvZ11 m?gXrhK6yOc4g-i5WgLj9AbAl2nRk50XKUbzbRtC2sOpr2e8bOTKzjG5n
NOTES-
12) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 125 lb down and 61 lb up at 10-8-12, 125 lb down and 61 lb up at
12-8-12, 125 lb down and 61 lb "up at 14-8-12, 125 lb. down and 61 lb up at 16-8-12, 125 lb down and 61 lb up at :18-8-1.2, 125 lb down and 61 lb up at 19-3-4, 125 lb
down and 61 lb up at 21-3-41125 lb down and 61 lb up at*23-3-4, and 125 lb down and 61 Itoup at 25-3-4, and 125 lb down and 61 lb up at 27-3-4 on top chord, and
1168 lb down and 966 lb up at: 8-8-0, 169 lb down,and 217 lb up at 10-8-12, 169 lb down and 217 lb up at 12-8=12, 169 lb down and 217 lb up at 14-8-12, 169 Ito down
and 217 lb up at 16-8-12, 169 lb down and 217'Ib up at 18-8-12,169 Ib.down and 217 lb up at .19-3-4, 169 lb down and 217Ib up at 21-3-4, 169 Ito down and:217 lb up
at 23-3-4, 169, lb down and 217 lb up at 25-3-4, and 169 lb down and 217 lb up at 27-3-4, and 1168 lb down and 966 lb up at 29-4-0 on bottom chord. The
design/selectiorl of such connection devices) is the responsibility of others:
LOAD.CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-4=-54, 4-8=-54, 8-11=-54, 18-20= 20, 13-18=-20, 13-23=-20 .
Concentrated Loads (lb)
Vert: 18=-1168(F).13==1168(F) 6=-139(F) 15= 338(F)'26=-70(F) 28=-70(F) 30=-70(F) 31=-70(F) 32= 70(F).33==70(F) 35=-70(F) 37=-70(F) 38=-169(F) 39=-169(F)
40=-169(F) 41=-169(F) 42=-169(F) 43=-169(F) 44=-169(F) 45=-169(F)
Q :WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE M11-7473 rev. 1010312015 BEFORE USE.
°
Design valid for use only with MITek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not
a, truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into. the overall
building design, Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing..
M!Tek"
Is always.required for stability and to prevent collapse with possible personal Injury.and:property damage. For general guidance regarding the :
fabrication; storage, delivery, erection and bracing of trusses and truss systems, seeANSVrP11 GualB�yy Cdterlo,'DSB-89 and BCSI BuIldtng Component .
6904 Parke East Blvd.,
Safety Infonnatlorrvailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22$14.
Tampa, FL 33610
Job
Truss
Truss Type
Q,ty
Ply
LOT 32/1 WATERSTONE
T1947OB52
2254612
B01
Hip Girder
1
2
Job Reference (optional)
tfunaers virsRAOurce kviani uny, t-L); Ylant r lly, rL - 33bb/, 6.240 S t-eb [ 202U Mi I eK Inaustnes, Inc. I hU t-eb 2U 11:17:0L 202U F'age 1
I D:sKKHvj4Ck9imdNUr8t11GtzjGwT-fUdQIOBQ7nHm11 uU8yNygbhiLOeRsgXL6S4VXCzjG51
5-1-5 9-9-0 10-11-0 , 15-6-12 20-8-0
. 4-7-12 1-2-0 4-7-12 5-1-5
8x6 = _ Scale = 1:39.2
5x6 =
3 4 ... .. .. ...
1
Bx12 MT20H5 ' — 3x8 I I
6x12 MT20HS = 7xl0 =
x
HTU26 HTU26 ..
3x8 I C
6x12 MT20HS
1.5xB STP = HTU26
HTU26.
7xl0 = HTU26
HTU26 HTU26
HTU26
5-1-5
9-9-0
10-11-0
15-6-12 20.8-0
5-.1-5 .
4-7-12
1-2-0 .
4-7-12 5-1-5
Plate Offsets (X,Y)-- [1:0-4-7,Edgel,[3:0-3-8,0-2-41,.[4:0-3-8;0-2-41[6:0-4-7,Edge),.[7:0-4-12,0-1-81,
[8:0-3-8,0-4781, [9:0-3-8,0-4-81, [11:0-4-12,0-1-81
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc). Vdefl Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL . 1.25
TC • 0.64
Vert(LL) 0.30
7-8 >816 240
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.77
Vert(CT) -0.35
7-8 >710 180 ..
MT20HS 187/143
BCLL .0.0 '
Rep Stress Incir NO
WB 0.83
Horz(CT) 0.11
6 n/a n/a.
BCDL 10.0
Code: FBC2017/TPI2014:
Matrix -MS
Weight:.239 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 31 `Except'
TOP CHORD
Structural wood sheathing directly applied or 3-7=11 oc purlins.
3-4: 2x4 SP No.2
BOT CHORD
Rigid ceiling directly applied or 7-3-6 oc bracing. '
BOT CHORD 2x6 SP M 26
WEBS 2x4 SP No.3
WEDGE
Left: 2k4 SP. No.3; Right: 2x4SP No.3,
REACTIONS. (lb/size) 1=8111/0-8-0, 6=8139/0-8-0
Max Harz 1=-20.1(LC 6)
Max Uplift 1=-4530(LC 8), 6=-4973(LC 8),
FORCES. (lb) - Max. Comp./Max. Ten. -.All forces:250 (lb) or less except when shown.
TOP CHORD- 1-2=-14918/8717, 2-3=-10063/6147, 3-4=-9065/5629, 4-5==10062/6149, 5-6=-14885/9076
BOT CHORD 1-11=-7723/13349, 9-11=•7723/13349, 8-9=-5326/9065, 7-8=-8052/13318,
6-7=-8052/1331 & .
WEBS 2-11=-2132/4129, 2-9=-5002/2795, 3-9=-2611/4349, 4-8=-2623/4354, 5-8=-4967/3167,
5-7=-2442/4101
NOTES-
1) 2-ply truss to be connected together with 10d (0.131 "x3") nails as follows:
Top chords connected as follows: 2x4 - 1 row at 0-7-0 oc.
Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-5-0 oc.
Webs connected as follows: 2x4 - 1 row at 0-9-0 oc.'
2) All loads are considered equally applied to all plies, except if noted as -front (F) or back (B) face in the LOAD CASE(S) section. Ply to
ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Unbalanced roof live loads have been considered for this design. .
4) Wind: ASIDE 7-10; Vuit=166mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=B:Opsf; h=25ft; B=45ft; L=40ft; eave=5ft; Cat.
ll; Exp C; Encl., GCpi=0,18; MWFRS (directional); Lumber DOL=1'.60 plate grip DOL=1.60
5) Provide adequate: drainage to prevent water.po.nding.
6) All plates are MT20 plates unless otherwise indicated.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. -
8) ' This truss has been designed for a live load of 20.Opsf on the.bottom chord in all areas -where a rectangle 3-6-0 tall by 2-0.0 wide
will fit between the bottom chord and any other members.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=1b)
1=4530,6=4973.
10) Use Simpson Strong -Tie HTU26 (20-10d Girder, 14-10dx1 1/2 Truss,, Single Ply Girder) or equivalent spaced at 2-0-0 oc max.
starting at 5-442 from the left end'to 194-12 to connect truss(es)'to'front face of bottom chord:
11)'Fill all nail holes where:hanger'is in contact with lumber.
12) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 1495 lb down and 673.Ib up at
1-4-12, and 1495 lb down and 673 lb up at 34-12 on bottom chord.. The design/selection of such connection'device(s) is the
Thomas A. Albani PE N6.36380
MiTek USA, Inc. FL Cert 6634
064 paike East Blvd. Tampa FL 33616 .
Date:
February 20,2020
others.
WARNING - Verl1 design arar6eters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MI1-7473 rev. f0/03/2015 BEFORE USE.
Y P
-
Design valid for use only.w.ith MTeklai connectors. This design Is based only upon parameters shown. and Is for an individual building component, not
.
a truss system. Before use -the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing .
MiTek'
is always required for stability and to prevent collapse with possible personal injury and:property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSVIPII Guallty Criteria, DSB-89 and BCSI BuOdhtp Component
6904 Parke•East Blvd.
Safety Informatblavallable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. ..
Tampa, FL 33610
Job
Truss
Truss Type
Q)y
ply
LOT 32/1 WATERSTONE
T19470852
2254612
B01
Hip Girder
1
2.
Job Reference (optional)
ounu_ eia nmtauurce tnant t [Ly, r-L)� rmnt t.,ny, rL - 00001, tl.Z4U 5 reo r ZUZU MI 1 eK Inausines, Inc. i nu reo ZU 11:1 /:UZ ZUZU rage Z
I D:sKKHvj4Ck9imdNUr8t11GtzjGwT-fUdQlOBQ7nHm1I uU8yNygOhiLoeRsgXL6S4VXCzjG51
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced); Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-3=-54, 3-4=-54, 4-6=-54, 1-6=-20
Concentrated.Loads (lb)
Vert: 11=-1466(F) 7=-1466(F) 16=-1495.17=-1495 18=-1466(F) 19=A466(F) 20=-1466(F) 21- 1466(F) 22= 1466(F) 23=-1466(F)
0:WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED M/TEK REFERANCE PAGE MII-7473 rev. 1010312015 BEFORE USE.
Design valid for use only with Mltek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into, the overall
building design, Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing.
Meek'
Is alwoys:required for stability and to preventcollapse with possible personal injury.and:property damage. For general guidance regarding the . '
fabrication; storage, delivery, erection and bracing of trusses and truss systems, seeANSVWII Quality Criteria. DSB49 and SCSI Building Component.
Safety Informationavallable from Truss Plate Institute, 218 N. Lee Street, Suite 312, A exandria, VA 22314.
.
6904 Parke'East Blvd.
Tampa, FL 33610
Job
Truss p
Truss Type
ON
Ply
LOT 32/1 WATERSTONE
T19470853
2254612
B02
Hip
1
1
Job Reference (optional)
ouuuera rnarouurce trmnt uriy, rL/, - riani i.riy, rL - 0a001, MZ41.1 S reD T zuzu MI I eK InauSineS, Inc. I nu reD zu 11:1 T:u2 2uzu rage 1
ID:sKKHvj4Ck9imdNUrBt11GtzjGwT-fUdQlOBQ7nHm11uU8yNygOhk9OgKsgW L6S4VXCzjG51
4-9-4 9-0-6 11-8-0 15-10-12 20-8-0
4-9-4 ' 4-2-12 . 2-8-0 4.2-12 4-9-4
Scale = 1:37.2
4x6 =
5x8 =
3 4
3x6 = 3x8 = 3x6 = 3x4 =
3x6 =
9.0-0 11-B-0 20-8-0
9.0-0 2-8-0 9-0-0
Plate Offsets (X,Y)--[1:0-6-0,0-0721,[4:0-6-0,0-2-8],[6:0-2-12,0-1-81
LOADING (psf)
SPACING- 2-0=0
CSI.
DEFL. in (loc) I/defy Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0:46
Vert(LL) -0.14 7-15 >999 240
MT20 244/190
TCDL 7.0
LumberDOL' 1.25
BC. ..0.65
Vert(CT) . -0.31 7-15 >809 180 .
BCLL . 0.0
Rep Stress Incr YES
WB 0.19
Horz(CT) 0.04 6 n/a n/a
BCDL 10.0
Code. FBC2017lfP12014
Matrix -AS
Weigfit:.99Ib FT=20% .
LUMBER- BRACING- "
TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly
applied.
BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied.
.
WEBS 2x4 SP No.3
REACTIONS. (lb/size). 1=765/0-8-0, 6=765/0-8-0
Max Horz 1=-186(LC 10)
Max Uplift 1=-431(LC 12), 6=-431(LC 12)
FORCES. (lb) - Max. Comp./Max: Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-1331/1100, 2-3— 1045/842, 3-4= 886/837, 4-5=-1044/841, 5-6=-1331/1100
BOT CHORD 1-9=-923/1203, 7-9=-486/885, 6-7=-901/1177
WEBS 2-9= 388/472, 3-9=-191/300, 4-7=-148/300, 5-7=-391/473
NOTES-
1) Unbalanced roof live loads have been considered for this design.
...
2) Wind: ASCE 7-10; V.61t=160rnph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=6.Opsf; h=25ft; B=45ft; L=40ft; eave=5ft; Cat.
ll Exp C; Encl., GCpi=0:18; MWFRS (directional) and C-C Exterior(2) 0-0-0 to 4-0-0, Interfor(1) 4-0-0 to 97070, Exterior(2) 9=0-0 to
17-3-1'4, Interior(1)� 17-3-14 to 20-8-0 zone;C-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate
grip DOL=1.60
3) Provide adequate drainage to.prevent water pending.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) " This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between th,e,bbttom chord and. any other:members.
6) Provide mechanical connection (by others)'of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except at=lb)
1=431, 6=431.
7) :This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum
sheetrock be applied directly to the bottom chord.
Thomas A. Albani PE No.38380
Mi rek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 3361(t .
Date:
February 20,2020.
PAGES BEFORE USE.
WARNING - Verifydesign arameters and READ NOTES ON THIS AND INCLUDED RE g p M KREFrs
"
Design valid for use only, with MITek®connectors. This design is based only upon parameters show and is for an Individual building component, not
idual)bull
show for an Individual
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design, Bracing Indicated'is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
NOW
Is always required for stability and to prevent collapse with possible personal Injury and:property damage. For general guidance regarding the:
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSVIPII Quality Cdlerla,'DS1349 and SCSI Buadtng Component.
6904 Parke East Blvd.
Safety Informationavallabie from Truss Plate Institute, 2.18 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qly
fly
LOT 32/1 WATERSTONE
T19470B54
2254612
B03
Hip Girder
1
1.
Job Reference (optional)
ouiwcis n,aWuu,ce tr,dnl �riy, 1Lh rrdrll idly, rL - 0000i, O.44a s reo r ZYeu IVII I eK Inuusines, inc. 1 nu reo zu 1 i:i im4 zuzu rage l
ID:sKKHvj4Ck9imdNUrBt11GtzjGwT-bslAA4CgfPXUG32sFN PQIpm_UpKS KhgeZmZcc54G5j
1-4.0 7-0.0 10-4.0 13-8.0' 20-8-0 22-0.0
1-4-0 ' 7-0-0 3.4-0 3-4-0 7-0-0 1-4-0
Scale = 1:38.0 "
Special
4x6 = NAILED Special
NAILED 3x4 = NAILED 4x6 = "
3 17 1 B 4 19 20 5
Io'.
4x6'= NAILED NAILED
4x6 = 3x4 = .3x4 = 44
x6
Special Special
7.n.n _ va.a.n ... on-a.n
m
0
m
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL, in (lop): . I/deft Lid
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.85
Vert(LL) 0.17 10-13 >999 240
MT20 - 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.80
Vert(CT) -0.27 : B-10 >905 180
BCLL 0.0 '
Rep Stress Incr NO
WB ".0.33
Horz(CT) 0.07 6 n/a n/a
BCDL 10.0
Code FBC2017ITP12014
Matrix -MS
Weight: 92 lb FT = 20
LUMBER- BRACING -
TOP CHORD 2x4 $P Nd.1 *Except* TOP CHORD Structural wood sheathing directly applied.
3-5: 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or4-10-1 oc bracing.
BOT CHORD' 2x4 SP NOA
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 2=1625/0-8-0, 6=1625/0-8-0
Max Horz 2=172(LC 7)
Max Uplift 2=-1039(LC 8), 6=-1039(LC 8)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown..
TOP CHORD 2-3=-2993/1734, 3-4=-2644/1645, 4-5=-2644/1645, 5-6=-2993/1734
BOT CHORD 2-10=-1354/2682, 8-10=-1579/2872, 6-8=-1354/2603
WEBS 3-10=-264/881, 4-10= 371/427, 4-8— 371/427, 5-8— 264/881
NOTES-
. ..
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; B=45ft; L=40ft; eave=51ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent waterpdnding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to.bearing plate capable of withstanding 100 lb uplift at joint(s) except at=lb)
2=1039, 6=1039.
7) "NAILED" indicates 3-1 Od (0.148"x3") or 3-12d (0.148"x3.25") toe -nails per NDS guidlines.
8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 329 lb down and 408 lb up at
7-0-0, and 329 lb down and 408:lb up at 13-8-0 on top chord, and 373 lb down and 123 Ib:up at 7-0-0, and 373 lb down and 123 lb
up at 13-7-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others.
9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase--1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-3=-54, 3-5=-54, 577=-54, 11-14=-20
Concentrated Loads (lb)
Vert:3=-165(F) 5=-165(F) 10=-361(F) 4=-117(F) 8=-361(F) 17=-117(F) 20= 117(F) 21= 59(F) 22=59(F) 23=-59(F)
Thomas A. Albani PE N6.36360
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610'
Date:
February 20,2020
:WARNING -Verify deslgn parameters and READ NOTES ON THIS AND INCLUDED M/TEK REFERANCE PAGE MIP7473 rev. 1010312015 BEFORE USE.
*
Design valid for use onlywith MiTeW connectors, This design Is based only upon parameters shown, and Is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design, Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing .
NNW
Is always required for stability and to prevent collapse with possible personal Injury and:property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSVIPll Quality Cdterla, DSB-69 and SCSI BuAding Component:
6904 Parke East Blvd.
Safety Informatlonavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qfay
Ply
LOT 32/1 WATERSTONE
0,
T19470855
2254612
C1
Jack -Open
8
1
Job Reference (optional)
t5.z iu s rep r zy?u MI I eK Inauslnes, rnc. I nu rep zu 1 in /:u4 zuzu rage 1 ,
ID:v3HtyczpYvZ11 m?gXrhK6yOc4g-bsIAA4CgfPXUG32sFNPQIpmBHp W KKmzeZmZcc5zjG5j
0-11-4
0-11-4
oununia nistauwcn tnant uny, rL/, rmnt t.rty, rL - 30=1,
:-1-4-0
.1-4-0
1
LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc), I/de.fl Ud PLATES : GRIP
TCLL 20.0 Plate Grip DOL 1.25 TC 0.22 Vert(LL) 0.00- 5 >999 240 MT20 244/190
TCDL .7.0 Lumber DOL 1.25 6C' :.0.04 Vert(CT) 0.00 5 >999 180
BCLL 0.0 Rep Stress Incr YES WB 0.00. Horz(CT) 0.00 4 n/a n/a.
BCDL 10.0 Code. FBC2017ITP12014. Matrix -MP Weightr5lb FT=20%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.2 TOP CHORD _ Structural wood sheathing directly applied or 0-11-4 oc purlins.
BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size). 3= 3/Mechanical, 2=158/0-8-0; 4=-15/Mechanical
Max Harz 2=91(LC 12)
Max Uplift 3=-3(LC 1), 2=-227(LC 12), 4— 1'5(LC'1)
'Max Grav 3=23(LC 12), 2=15B(LC 1), 4=51(LC 12)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE.7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=42Psf; BCDL=6.Opsf; h=25ft; B=45ft; L=40ft; eave=6ft; Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions
shown; Lumber.DOL=1.60 plate grip'DOL=1.60
2) 'This truss has been designed for. a 10.0 psf bottom chord live load nonconcurrent.with any other live loads.
3) his truss has been designed for alive load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the,bottom chord and any other members.
4) Bearings are assumed to be: Joint 3 SYP No.2crushing capacity of 565 psi, Joint 4 SYP No.2 crushing capacity of 565 psi.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 4 except (jt=lb)
2=227.
Thomas A: Albani PE N6.39380
MTek USA, Inc. FL Cod 6634
6904 Parke East Blvd. Tampa FL 33616
Date:
February 20,2020
A WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE M11-7473 rev. 10/0&2015 BEFORE USE.
Design valid for use oniywith MlTek® connectors. This design is based only upon parameters shown, and Is for an individual building component, not
a,truss system. Before use, The building designer must verity the applicability of design parameters and properly Incorporate this design into the overall
building design, Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporaryand permanent bracing
MITek'
Is always:required for stability and to prevent collapse with possible personal Injury and:property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/iPll Quo' By CrBerla, DSB-89 and BCSI BuBdkrp Component:.
6904 Parke East Blvd.
Safety Informationavallabie from Truss Plate Institute, 2.18 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
City
Ply
LOT 32/1 WATERSTONE
T19470856
2254612
CiP
JACK -OPEN
6
1
Job Reference (optional)
ouuueis nrarouurce trrdlu uny, rr-1, ndn[ carry, rL - OCoai, t1.Z4u s rel) / 2U2U MI I eK Inausmes, Inc. I nu reb zu 11:17:05 2020 t'age 1
ID:v3HtyczpYvZl 1 m?gXrhK6yOc4g-33JYOQDIQifLuDd3p4wflOIJi DsZ3DDnoQJ9BXzjG5i
-1-4-0 0-11-4
1-4-0 0-11-4
Scale = 1:7.6 .
3
1.
v
o'
m .
0
N
N
..
6
0-11-4
0-11-4
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc): I/dell Lid
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.22
Vert(LL) 0.00 5 >999 240
MT20 244/190
TCDL .7.0
Lumber DOL '1.25
BC 0.04
Vert(CT) 0.00 : 5 >999 180
BCLL 0.0
Rep Stress Incr YES
WB b.00
Horz(CT) 0.00 4 n/a n/a
BCDL 10.0
Code F8C2017/TP12014
Matrix -MP
Weight: 5lb FT=20%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 0-11-4 oc purlins.
BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or
10-0-0 oc bracing.
REACTIONS. (lb/size) 3=-3/Mechanical, 2=158/0-3-8, 4=-15/Mechanical
Max Harz 2=91(LC 12)
Max Up1"ift 3=-6(LC 9), 2= 246(LC 12),.4=-23(LC 1.7)
Max Grav 3=17(LC 12), 2=158(LC 1), 4=37(LC "12)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=6.Opsf; h=25ft; B=45ft; L=40ft; eave=6ft; Cat.
11; Exp C; End, GCpi=0.18; MWFRS (directional) and C-C Exterior(2). zone; porch left exposed;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 "
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other.live loads.
3) '. This truss has been:designed for a live load of 20.Opsf on I -he bottom chord in all areas where a rectangle 3-6-0 tall by 2-.0-0 wide
will fit between the bottom chord and any other members.
4) All bearings are assumed to be SYP No.2 crushing capacity of 565 psi.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at jbint(s) 3, 4 except 0t=lb)
2=246.
Thomas A.'Albani PE No.39380
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
February 20,2020
WARNING- Verify design parameters and READ NOTES ON THIS AND INCLUDED M/rEK REFERANCE PAGE M11-7473 V. IW03/2015 BEFORE USE.
'
Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
a.truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into, the overall
building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MITek-
is always required for stability and to prevent collapse with possible personal Injury ond.property damage. For general guidance regarding the
fabrication,: storage, delivery, erection and bracing of trusses and truss systems, seeANSUIPII Cuallly Criteria, DSB-89 and SCSI BuOdIng Component
6904 Parke East Blvd.
Safety Informallonavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type i
Qty
Ply
LOT 32/1 WATERSTONE
T19470857
2254.612
C1V .
Jack -Open
4
1.
Job Reference (optional)
ounuera niatauurce tndrn i 11y, rLI, ndnr Amy, rL - 0000r,
-1-4-0
1-4-0
tl.z4u 5 I-eo I 'LULU MI lax Inousines, Inc., I nu rep'Lu i i:1 t:ub zuzu rage 1
ID:v3HtyczpYvZ11 m7gXrhK6yOc4g-33JYOQDIQifLuDd3p4wfI01J1 Dsa3DDnoQJ9BX2jG5i
0-11-4
Scale =
0
m
0
Plate Offsets (X,Y)-- [2:0-0-15,Edge)
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc). • . I/dell , Ud
PLATES : GRIP
TCLL 20.0 ' -
Plate Grip DOL 1.25
TC 0.22
Vert(LL) 0.00 7 >999 240
MT20 244/190
TCDL .7.0
Lumber DOL 1.25
BC .0.04
Vert(CT) 0.06 7 >999 180
BCLL 0.0
Rep Stress Incr YES
WB 0.00
Horz(CT) 0.00 2 n/a n/a
BCDL7 10.0
Code .FBC2017/TPI2014
Matrix -MP
Weight::5 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 0-11-4 cc purlins.
BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 6-0-0 cc bracing.
REACTIONS. (lb/size); 3=-4/Mechanical, 2=158/0-8-0; 4=-14/Mechanical
Max Harz 2=91(LC 12)
Max Uplift 3=-4(LC 9), 2=:211(LC 12), 4=-14(LC'1)
Max Grav 3=18(LC 12), 2=158(LC 1), 4=41(LC 12)
FORCES. (Ib) - Max. Comp./Max: Ten. - A(I forces 250 (lb) or less except when shown..
NOTES-
1) Wind: ASCE 7-10;-Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.20sf; BCDL=6.Opsf; h=25ft; B=45ft; L=40ft; eave=6ft; Cat.
Il; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions
shown; Lumber DOL=1.60 plate.grip: DOL=1.60'
2) This truss has been designed fora 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between_the bottom chord and any other.members.
4) All bearings are assumed to be SYP.No,2 cnishing capacity of 565. psi.
5) Refer to girder(s) for truss to truss connections.
6) Bearing at joint(s) 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface. .
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 4 except at=lb)
2=211.
Thomas A. Albani PE No.39380
MTek USA, Inc. FL Cert6634
6904 Parke East Blvd. Tampa FL 33610 .
Date:
February 20,2020
Q WARNING -Verify dealgn parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MX7473 rev. 1010312015 BEFORE USE.
°
Design valid for use only with Mliek® connectors. This design Is based only upon parameters shown, -and is for an Individual building component, not
. .
a, truss system. Before use, the building designer must verify the applicabllity of design parameters and properly incorporate this design Into the overall
building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing .
MOW
Is always required for stability and to prevent collapse with possible personal Injury and:property damage. For general guidance regarding the.
fabrication, storage, delivery, erection and bracing of trusses and truss systems,'seeANSVTP11 Quality Cdtedo, DSB-89 and BCSI Bullding Component:
6904 Parke East Blvd.,
Safety Informatlanovailabie from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type r
City
Ply
LOT 32/1 WATERSTONE
T19470858
2254612
C3
Jack -Open
8
1
Job Reference (optional)
trunaers I-Irsibource truant Gqy, t-L.), Plant tarty, FL - 33bti7, 6.24y s Feb 7 2UZU Mr I eK Industries, Inc. I nu Feb 20 11:17:06 2020Page 1
ID:v3HtyczpYvZ1'i m?gXrhK6yOc4g-XFtxbmExBOoCVMCFNoRugErTmdAwogTx042jg7AG5h
1-4-0 2-11-4
1-4-0 2-11=4.
Scale=.1:12.7
3
6.b0 12
2-11-4
2-11-4.'
Plate Offsets (X,Y)-- [2:0-4-4,0,074]
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) I/defl Ud
PLATES GRIP
TCLL 20.0 -
Plate Grip DOL 1.25
TC 0.22
Vert(LL) -0.00"
4-7 >999 240
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0:10
Vert(CT) -0.01
4-7 >999 180
BCLL 0.0 ' .
Rep Stress Incr YES
WB . 0.00
Horz(CT) -0.00
3 n/a n/a
BCDL 10.0
Code. FBC2017frP12014:
Matrix -MP
Weight: 12 lb FT = 20 %
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.2
TOP CHORD
Structural wood sheathing directly applied or 2-11-4 oc purlins.
BOT CHORD 2x4 SP No.2
BOT CHORD
Rigid ceiling directly applied or.10-0-0 oc bracing.
REACTIONS. (lb/size) 3=59/Mechanical, 2=195/0-8-0, 4=30/Mechanical
Max Harz, 2=152(LC 12)
Max Uplift 3— 62(LC 12), 2=-183 LC 12
Max Grav 3=70(LC 17), 2=195(LC 1), 4=49(LC 3)
FORCES. (lb) - Max. Comp./Max: Ten. -All forces 25.0 (lb) or less except when shown..
NOTES-
Z) I nis truss nay Deen aesignea roc a 1 u.0 psi Donom cnora live roaa nonconcurreni Win any airier live Ioaas.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6
will fit between the,bottom chord and any other,mertibers.
4) All bearings are assumed to be SYP'No.2 crushing capacity of 565 psi.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection .(by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint
. 2=183.
?-0-0 wide
apt at=lb)
Thomas A. Albani PE No.39380
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date: -
February 20,2020
Q WARNING - Ved ry design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MX7473 rev. 1010312015 BEFORE USE.
Design valid for use only, with MRek0 connectors. This design Is based only upon parameters shown, and Is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design, Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporaryand permanent bracing _
MiTek'
is always:recluired. for stability and to prevent collapse with possible personal injury.and property damage. For general guidance regarding the :
• . :
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSVTPII Quality Criteria, DSB-89 and SCSI BuOding Component .
6904 Parke East Blvd.
Safety Informationavailable from Truss Plate Institute, 218 N. Lee Street. Suite 312, Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
LOT 32/1 WATERSTONE
T19470859
2254612
C3P
Jack -Open
4
1
.
Job Reference (optional)
„Yny, 11), r-11L . ty, rL - oouuf' a,Z9U 5 reD t ZUZU WN 1 eK Inausine6, mc. I nu reD ZU l 1:1 /:U/ ZUZU rage 1
ID:GZkZSXBELDNJdjXs77WskQzGxTm-?RRJp6FZyKw37WnRwVy7NRObO1 U1 X7j4FkoGDQzjG5g
.1-4-0 2-11-4'
1.4-0 2-11-4
Scale = 1:12.7
Plate
LOADING (psf) SPACING- 2-0-0 CSI. DEFL, in (loc) I/dell Ud PLATES GRIP
TCLL 20.0 Plate Grip DOL 1.25 TC 0:38 Vert(LL) 0.02 4-7 >999 240 MT20 244/190
TCDL 7.0 Lumber DOL 1.25 BC. 0.23 Vert(CT) 0.02 4-7 >999 180
BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a
BCDL 10.0 Code FBC2017fTP12014: Matrix -MP Weight: 12lb FT=20%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 2-11-4 oc purlins.
BOT CHORb 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 3=60/Mechanical, 2=195/0-3-0, 4=30/Mechanical
Max Horz 2=152(LC 12)
Max Uplift 3- 73(LC 12), 2= 245(LC 12),4=-45(LC 9).
Max Grav 3=62(LC 17), 2-7.195(LC 1), 4=49(LC 3)
FORCES. (lb) - Max. Comp./Max: Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE.T 10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=6.Opsf; h=25ft; B=45ft; L=40ft; eave=4ft; Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Corner(3) zone; porch left exposed;C-C for members and forces &
MW FRS for reactions shown; Lumber DOL=1.60. plate grip DOL=1.60
2) This truss has been designed for. a 10.0 psf bottom chord live load nonconcurrent .with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the,bottom chord and any other members.
4) Bearings -are assumed to be: Joint 3 SYP No.2 crushing capacity of 565 psi, Joint 4 SYP No.2 crushing capacity of 565 psi.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding_ 100 lb uplift at joint(s) 3, 4 except at=lb)
2=245.
Thomas A. Albani PE No.36360
Mi rek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Data:
February 20,2020
Q WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE Ml1-7473 rev. 1010312015 BEFORE USE.
Design valid for use only. with MlTek® connectors. This design Is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporaryand permanent bracing..
MiTek'
Is always:required for stability and to prevent collapse with possible personal Injury ond:propedy damage. For general guidance regarding the. I. .
fabrication; storage, delivery, erection and bracing of trusses and truss systems, seeANSVWII Quality Criteria, DS13-89 and BCSI BuOdlnp Component
6904 Parke East Blvd.
Safety Infomratlonavallable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 33610 ,
Job
Truss
Truss Type
Qty
Ply
LOT 32/1 WATERSTONE
T19470860
2254612
C3V
Jack -Open
4
1
Job Reference (optional)
y, "i a . y, o.cvu s reu / LVN IVII I eK Inaa5ir1e5, inc. I nU rGo ZU I I:I /:U/ LULU rage
I D:v3HtyczpYvZl l m?gXrhK6yOc4g-?RRJp6FZyKw37W nRwVy7NROeW 1 W zX7j4FkoGDQzjG5g
140 2114
1-4-0 .2-11-4
Scale = 1:12.7
0
m
Plate Offsets (X,Y)- [2:070-15;Edgej
LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc). Vdefl Ud PLATES GRIP
TCLL 20.0 Plate Grip• DOL 1.25 TIC 0:22 Vert(LL) 0.01 - 4-7 >999 240 MT20 244/190
TCDL .7.0 Lumber DOL 1.25 BC: :.0.11 Vert(CT) -0.01 4-7 >999 '180
BCLL 0.0 ' Rep Stress Incr YES WB 0.00, Horz(CT) 0.00 3 n/a n/a
BCDL 10.0 Code. FBC2017lrP12014: Matrix -MP Weight 12 lb FT = 20%
LUMBER- BRACING -
TOP CHORD_ 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 2-11-4 oc purlins.
BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or.10-0-0 oc bracing.
REACTIONS. (lb/size) 3=60/Mechanical, 2=195/0-8-0, 4=29/Mechanical
Max Horz 2=152(LC 12)
Max Uplift 3=-67(LC 12), 2= 174(LC 12)
Max Grav 3=72(LC 17), 2=195(LC 1), 4=49(LC 3)
FORCES. (Ili) - Max. Comp./Max: Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASIDE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=6.Opsf; h=25ft; B=45ft; L=40ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions
shown; Lumber.DOL=1.60 plate gdp.DOL=1.60 .
2) 'This truss has been designed fora 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been'designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will flit between the bottom chord and any other members.
4) Bearings are -assumed to be: Joint 3 SYP No.2crushing capacity of 565 psi, Joint 4 SYP No.2 crushing capacity of 565 psi.
5) Refer to girder(s) for truss to truss connections.
6) Bearing at joint(s) 2 considers. parallel to grain value using ANSVTPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s)3 except Gt=lb)
2=174.
Thomas A. Albani PE No.39380
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date: .
February 20,2020
A:WARN/NG -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE114II-7473 rev. f 0/03(2015 BEFORE USE.
Design valid for use only with MITek® connectors, This design is based only upon parameters shown, and is for an Individual bullring component, not
a,truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design, Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary'and permanent bracing
MiTek'
Is always:required. for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication; storage, delivery, erection and bracing of trusses and truss systems, seeANSI/1PI1 Quality Cdterla, DSB-89 and SCSI Bullding Component:.
6904 Parke East Blvd.
Safety Infoanatlonovailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
city
Ply
LOT 32/1 WATERSTONE
T19470861
2254612
C5
Jack -Open
4
1
Job Reference (optional)
uuu�o,a , uaw�ww �� ia, n yny, —J, I —a uuy, r 7 - ooaor, o.z�ty s reo I ZUZo IVIr r eK rnuusines, dna. 1 nu rem zu i in /:utf zuzu rage 1
ID:sKKHvj4Ck9imdNUrBtl lGtzjGwT-Ue?hOSFBjd2wlgMeUCTMvfwIKQnW GazEUOXplszjG5f
-1-4-0 . 4-11-4 . .
1.4-0 4-11-4
Scale = 1:17.6
LOADING (psf)
TCLL 20.0
TCDL 7.0
BCLL .. 0.0 '
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr YES
Code. FBC2017ITP12014.
CSI.
TC 0:48
BC ..6'41
WB 0.00
Matrix -AS
DEFL. in (loc) - I/deft Ud
Vert(LL) 0.06' 4-7 >999 240
Vert(CT) -0.06 4-7 >999 180 .
Horz(CT) -0.00 3 n/a n/a.
PLATES GRIP
MT20 244/190
Weight 181b FT=20% .
LUMBER- BRACING -
TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied.
BOT CHORb 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied.
REACTIONS. (lb/size), 3=114/Mechanical, 2=262/0-8-0, 4=57/Mechanical
Max Harz 2=214(LC 12)
Max Uplift 3=-128(LC 12),,2=-196,(LC12)
Max Grav 3=133(LC 17), 2=262(LC 1), 4=86(LC 3)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-1D; Vult=160mph (3-second, gust) Vasd=124mph; TCDL=4.2psf; BCDL=6.Opsf; h=25ft; B=45ft; L=40ft; eave=5ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-4-0 to 2-8-0, Interior(1) 2-&0 to 4-10-8 zone;C-C for
members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
r
2) This truss has been designed for. a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been'designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-670 tall by 2-0-0 wide
will fit between the .bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except at=lb)
3=128,2=196.
.. 6) This truss design requires.that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum
sheetrock be applied directly to the bottom chord.
Thomas A: Albani PE N6.39360
MiTek USA, Inc. FL Cert 6634
. . .
6904 Parke East Blvd. Tampa FL 33610 .
Date:
February 20,2020
0 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE 111I1-7473 rev. l a(03)2015 BEFORE USE:
'
Design valid for use only with MITek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design, Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek'
Is always required_for stability and to prevent collapse with possible personal injury and;property damage. For general guidance regarding the,
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSU1P11 Quality Criteria, D513-09 and SCSI Bugding Camponent
6904 Parke'East Blvd.
Safety Infonnatfonovailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, I'L 33610
Job
Truss
Truss Type
Qh/
Ply
LOT 3211 WATERSTONE
T19470862
2254612
C5V
Jack -Open
4
1
Job Reference (optional)
Dunueis niStDUurUV tnant wy, rL1r runt Ulty, rL - 00001,
-1-4-0
ex4
Plate Offsets (X,Y)-- [2:0-0-15,Edgel
C5.Z4U 5 reD r ZUZU MI I eK Inausines, Inc. I nu reD ZU 11:1 r:Ud ZUZU rage i
ID:v3HtyczpYvZ11 m?gXrhK6yOc4g-Ue?hOSFBjd2wlgMeUCTMvfwloQnxGazEUOXplszjG5f
4-11-4
4-11-4
Scale = 1:17.6
C?
d,
n
9.6
LOADING (psf)
SPACING-
2-0=0
CSI.
DEFL.
in
(loc)
_ Well • "
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0:51
Vert(LL)
0.06
4-7
>923
240
MT20 2441190'
TCDL 7.0
Lumber DOL
1.25
BC. 0.45
Vert(CT)
-0.06
4-7
>999
180
-
BCLL 0.0
Rep Stress Incr
YES
WB 0.00
Horz(CT)
-0.01
3
n/a
n/a
BCDL 10.0
Code. FBC2017/TP12014
Matrix -AS
Weight: 18 lb FT = 20
LUMBER- BRACING -
TOP CHORD 2x4 SP No.2 TOP CHORD. Structural wood sheathing directly applied.
BOT CHORD- 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied.
REACTIONS. (lb/size) 3=115/Mechanical, 2=262/0-8-0, 4=56/Mechanical
Max Harz 2=214(LC 12)
Max Uplift 3=-133(LC 12), 2=-189_(LC 12)
Max Grav 3=134(LC 17), 2=262(LC 1), 4=86(LC 3)
FORCES. (lb) - Max. Comp./Max: Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4,2psf; BCDL=6.Opsf; h=25ft; B=45ft; L=4011; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-4-0 to 2-8-0, Interior(1) 2-8-0 to 4-10-8 zone;C-C for
members and forces & MWFRS for.reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between.the bottom chord and any other.members.
4) All bearings are assumed to be SYP No,2 crushing capacity of 565 psi.
5) Refer to girders) for truss to truss connections.
6) Bearing at joint(s) 2 considers parallel to grain value using ANSI/fPI 1 angle to grain formula. Building designer should.verify
capacity of bearing surface.
7) Provide mechanical connection.(by others) of truss to bearing plate capable of withstanding 100 Ito uplift at joint(s) except (jt=lb)
3=133, 2=189.: .
8) This truss design "requires that a minimum. of 7/16" structural wood"sheathing be applied directly to the top chord and 1/2" gypsum
sheetrock be applied directly to the bottom chord.
Thomas A. -Alban! PE No.39380
MiTek USA, Inc. FL Cent 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
February 20,2020
Q WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED M?EK REFERANCE PAGE M&7473 rev. 1010312015 BEFORE USE
Design valid for use only, with MITek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into. the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporaryand permanent bracing..
I �qA VI ffek'
Is always required for stability and to prevent collapse with possible personal Injury and: property damage. For general guidance regarding the
fabrication; storage, delivery, erection and bracing of trusses and truss systems, see/WSUVII Quality Cdteda; DSB.89 and BCSI BuBding Component
6904 Parke East Blvd.
Safety Informationavoiloble from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
LOT 3211 WATERSTONE
T19470863
2254612
C7V
Jack -Open
4
1
Job Reference (optional)
uuw,uula nialouu— tn4nl yuy, 11l, r141IL idly, rL - 00001, o.44u s r'ep i eueu mi i eK inauslnes, inc. I nu rep 2u l in t:uu zuzu- rage T
ID:v3HtyczpYvZ11 m?gXrhK6yOc4g-ygZ3DoGpUxAmMgwg2w.9bSsTrsglt?1 CNj2HNHIzjG5e
-1-4-0 6-11-4
1-4-0 6-11-4
Scale = 1:23.1
3x4
Plate uirsets tA,Yj-- I2:u-Y-i1,U-u-6j
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc), I/defl Ud
PLATES' GRIP
TCLL 20.0 _
Plate Grip, DOL 1.25
TC 0.81
Vert(LL) 0.20
4-7 >411 240
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.78
Vert(CT)' -0.19
4-7 >430 180
BCLL 0.0 ' .
Rep Stress Incr YES
WB 0.00
Horz(CT) -0.03
3 n/a n/a.
BCDL 10.0
Code FBC2017frP12014
Matrix -AS
Weight: 25 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4'SP No.1
TOP CHORD
Structural wood sheathing directly applied.
BOT CHORD' 2x4 SP No.2
BOT CHORD
Rigid ceiling directly applied.
REACTIONS. (lb/size) 3=170/Mechanical, 2=333/0-8-.0, 4=77/Mechanical
Max Harz 2=276(LC 12)
Max Uplift 3=-198(LC 12),.2=-210.(LC 12)
Max Grav 3=198(LC 17), 2=333(LC 1), 4=120(LC 3)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.-
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (3-second gust)' Vasd=124mph; TCDL=4.2psf; BCDL=6.Opsf; h=25ft; B=45ft; L=40ft; eave=6ft; Cat.
II; Exp'C;•Encl., GCpi=0.18; MWFRS (directional) and C-C Exterjor(2) -14-0 to 2-8-0, Interior(1) 2-8-0 to 6-10-8 zone;C-C for
members and forces & MWFRS for. reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for. a 10.0 psf bottom chord live load nonconcurrent with any other live loads. -
3) ' This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other.members.
4) All bearings are assumed to be SYP No.2 crushing capacity of 565 psi:.
5) Refer to girder(s) for truss to truss connections.
6) Bearing at joint(s) 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should.verify
capacity of bearing surface. .
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except at=lb)
3=198, 2=210:
8) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top, 'chord and 1/2" gypsum:
sheetrock be applied directly to the bottom chord.
Thomas A: Albani PE No.39380
MiTek USA, Inc. FL Cert6634
6904 Parke East Blvd. Tampa FL 33610
Date:
February 20,2020 .
0 WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFER_ ANCE PAGEMIP7473 rev. 10/0312015 BEFORE USE,
Design valid for use only with MITek@ connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design, Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing .
^
" /� iTek"
Is always requiredfor stability and to prevent collapse with possible personal Injury and:property damage. For general guidance regarding the :
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see/WSViPII Quality Criteria, DSB-89 and SCSI BuIlding Component
6904 Parke East Blvd.
Safety Infonnatlonovallable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL .33610
Job
Truss
Truss Type r
City
Ply
LOT 32/1 WATERSTONE
T19470864
2254612
E3
JACK -OPEN
4
1
Job Reference (optional)
ounuers rrrscauurce trranl Idly, rL), r Tani Idly, rL - JJ001, 0.zqu s reD t zuzu Mr i eK maustnes, mC. i nu reD ZU 11:1 t:1U ZUZU rage 1
ID:v3HtyczpYvZl l m?gXrhK6yOc4g-OO6RR7HRFFld_VOcdWq?409mEXikUSWxilwplzjG5d
1-4-0 3.0.0
1-4-0 3-0-0
Scale = 1:12.8'
3-0-0 .
3-0-0
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc): ,I/defl Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.22
Vert(LL) 0.02 4-7 >999 240
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.17
Vert(CT) -0.01 4-7 >999 180
BCLL 0.0
Rep Stress Incr. YES
WB .0.00
Horz(CT) -0.00 3 n/a n/a
BCDL 10.0
Code FBC2017ITP12014
Matrix -MP.
Weight: 12 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 3-0-0 oc purlins.
BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 3=61/Mechanical, 2=197/0-3-8, 4=31/Mechanical
Max Harz 2=154(LC 12)
Max Uplift 3=-75(LC 12), 2— 246(LC 12), 4=-46(LC 9)
Max Grav 3=64(LC 17), 2=197(LC 1), 4=50(LC 3)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vu1t=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; B=45ft; L=40ft; eave=6ft; Cat.
11; Exp C;.Encl.; GCpi=0.18; MWFRS (directional) and C-C Exterior(2). zone;.porch left exposed;C-C for members and forces & _
MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOLm1'.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) *.This truss has been.designed for a live load of 20.Opsf on.the.bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom�chord and any other members.
4) Bearings are assumed to be: Joint 3 SYP Not. crushing capacity of 565 psi, Joint 4 SYP No.2 crushing capacity of 565 psi.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1001b uplift at joint(s) 3, 4 except at=lb)
2=246:
Thomas A:Albani RE No,39360
Mi rek USA, Inc. FL Cert 6634
6164 Parke East Blvd. Tampa FL 33610
Date:
February 20,2020
WARNING -Verify deslgn parameters and READ NOTES ON THIS AND INCLUDED M?EK REFERANCE PAGE MIP7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an individual building component, not
a.truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
bullding deslgn. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing.
MiTek'
Is always required for stability and to prevent collapse with possible personal Injury and: property damage. For general guidance regarding the -
fabrication, storage, delivery, erection and bracing of trusses and truss systems,'seeANSI/Tpll Qua[ Criteria, DSB-69 and SCSI BuOdtng Component
6904 Parke East Blvd.,
Safety InformaBonovailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type ,
Qtj/
Ply
LOT 32/1 WATERSTONE
T1947OB65
2254612
E5
Jack -Open
2
1
Job Reference (optional)
-.,y, 1 11, 1—., .,,,y, F, - ooaDi , D.cva 5 reu r zuzu rvu 1 erc 1nausme5,.1nc. i nu reo zu 1 i:1 r;ii zuzu rage i
ID:v3HtyczpYvZl l m?gXrhK6yOc4g-uDggeT130YQUc84C9L13XHYGKep_TwigAMmUMBzjG5c
i -11
0 5-0-0
1-4-0 5 0.0
Scale = 1:17.8
3
1 T.. ..
1
3x4 =
5-0-0
5-0-0
Plate.Offsets (X,Y)--
[2:0-1-4,070-21
LOADING (psf)
SPACING- 2-0-0 "' :
CSI.
DEFL.
in
(loc)
I/defl
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0:49
Vert(LL)
0.06 .
4-7
>967
240
MT20 244/190-
TCDL 7.0
Lumber DOL 1.25
BC 0.42
Vert(CT) .
-0.06
4-7
>999
180
BCLL 0.0 '
Rep Stress Incr YES
WB 0.00
Horz(CT)
-0.00
3
n/a
n/a
BCDL: 10.0
C6de FBC2017lrP12014
Matrix -AS
Weight: 18 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP NO.2 TOP CHORD 'Structural wood sheathing directly applied.
BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied.
REACTIONS. (lb/size) 3=115/Mechanical, 2=264/0-8-0, 4=58/Mechanical
Max Horz 2=216(LC 12)
Max Uplift 3=-130(LC 12), 2=-196(LC 12)
Max Gray 3=134(LC 17), 2=264(LC 1), 4=87(LC 3)
FORCES. (lb) - Max. Comp:/Max. Ten. -All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10;,Vult=160mph (3-second. gust) Vasd=124mph; TCDL=4.2psf; BCD L=6.Opsf; h=25ft; B=45ft; L=40ft; eave=6ft; Cat.
II; Exp•C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-4-0 to 2-8-0, Interior(1) 2-8-0 to 4-11-4 zone;C-C for
members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf oh.the bottom chord in all areas'where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord -and any other members.
4) All bearings are assumed to be SYP No.2 crushing capacity of 565 psi.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except at=lb)
3=130,2=196.
7) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum
sheetrock be applied directly to the bottom chord.
Thomas A. Albani PE No.39380
M[Tek USA,'Inc, FL Cert 6634
6164 Parke East Blvd. Tampa FL 33610
Date:
February 20,2020
WARNING- Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MIP7473 rev. 10/03/2015 BEFORE USE.
Design valid for use only with MITek® connectors. This design Is, based only upon parameters.shown, and. Is for an Individual building. component, not
�-
a truss system. Before use; the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
bullding design. Bracing Indicated is to. prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
�/� k'
MOW
Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the'
fabrication; storage, delivery, erection and bracing of trusses and truss systems, seeANSUVII Quo' I�tyy Criteria, DSB-69 and BCSI Building Component
6904 Parke East Blvd.
Safety Informatlonavallable from Truss Plate Institute, 218 N. Lee Street, Suite'312, Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
LOT 32/1. WATERSTONE
T19470866
2254612
E51P
Jack -Open
6 1
1
Job Reference (optional)
u uaiouuiue tnarn vny, r�1, Warn i.uy, rL- OOaor,
-1-4-0
1-4 0
I:iO_uD4E
5-0.0
5-0.0
5-0-0
5.0-0
1 s reD f ZUZU MI I eK Inausines, Inc. I nu reD zu i in inn zuzu rage 1
5slpy6aEmzjfl L-MPECspJhnsYLDHfPj2Y14V5M4232CNypPOW 1 udziG5b
Scale = 1:17.8
m
0
N
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)','
I/defl
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TIC 0:81
Vert(LL)
0:17
4-7
>349
240
MT20 244/190
TCDL 7.0
Lumber DOL
1.25
BC . 0.75
Vert(CT) .
0.15
4-7
>388
.180
BCLL 0.0
Rep Stress Incr
. YES
WB 0.00
Horz(CT)
-0.01
3
n/a
n/a
BCDL 10.0
Code FBC2017fTP12014:
Matrix -AS
Weight: 18 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied.
BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied.
REACTIONS. (lb/size) 3=115/Mechanical, 2=264/0-3-8, 4=58/Mechanical
Max Horz 2=216(LC 12)
Max Uplift 3=-147(LC 12),.2=-302(LC 12), 4=-82(LC 1.2)
Max Grav 3=121(LC 17), 2=264(LC 1), 4=87(LC 3)
FORCES. (lb) - Max. CompdMax. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=6.Opsf; h=25ft; 13=45ft; L=40ft; eave=4ft; Cat. .
11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Comer(3) -1-4-0 to 2-8-0, Exterior(2) 2-8-0'to 4-11-4 zone; porch left
exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip.DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas'where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) All bearings are assumed to be SYP No.2 crushing capacity of 565 psi.,
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift atjoint(s) 4 except Qt=lb)
3=1.47, 2=302.
7) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum
sheetrock be applied' directly to the bottom chord.
Thomas A. Albani PE No:39360
MiTek USA, Ihc. FL Cert6634
6904 Parke East Blvd. Tampa FL 33610
Dater
February 20,2020
0 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MrrEK REFERANCE PAGE MU-7473 rev. 101=015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is. based only upon parameters shown, and. is for an Individual bullding component, not
a. truss system. Before use; the building designer must verity the applicability of design parameters and properly Incorporate this design into the overall
building design. Bracing indicated is to. prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MITe k'
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the ..
fabrication, storage, delivery, erection and bracing of trusses and truss "systems, see/WSVWII Quality Clttoda,.D51111.89 and SCSI Bu9ding Component
Saf@tV Infoenatlonovallabie from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
6904 Parke East Blvd.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
LOT 32/1 WATERSTONE
T19470867
2254612
E7 .
Jack -Open..
5
1
Job Reference (optional)
ouuuers nrsrauurce irranr %.ny, rLI, want L111y, rL- 0a001,
-1-4-0
1
ts.e4u s reo f zueu MI I eK Inauslnes, Inq. I nu reo zu 11 in f:1z zuzu rage i
I D:sKKHvj4Ck9imdNUr8t1 I GtzjGwT-MPECspJhnsYLDHfPi2Y14V5MT237CNypPOW 1 udzjG5b
7-0-0
7-0.0
Scale = 1:23.0
o0
6
m 7
co
Plate Offsets (X,Y)-- 12:0-2-10,0-1-81
LOADING (pso
SPACING- 2-0-0
CSI.
DEFL. in (loc) I/defl Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL' 1.25
TC 0.79
Vert(LL) 0.20 4-7 >426 240
MT20 244/190
TCDL 7.0
Lumber DOL . 1.25
BC 0.76
Vert(CT) -0.19 4-7 >432 180
BCLL 0.0 *
Rep Stress Incr YES
WB 0.00
Horz(CT) -0.01 3 n/a n/a
BCDL 10.0
Code FBC2017/TPl2014:
Matrix -AS
Weight: 24 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.1 TOP CHORD Structural wood sheathing directly applied.
BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied.
REACTIONS. (lb/size) 3=171/Mechanical, 2=336/0-8-0, 4=79/Mechanical
Max Horz 2=278(LC 12)
Max Uplift 3=-195(LC l2),,2=-217(LC12)
Max Grav 3=198(LC 17), 2=336(LC 1), 4=121(LC 3)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7=10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=6.Opsf; h=25ft; 13=45ft; L=40ft; eave=5ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-4-0 to 2-8-0, Intedor(1) 2-8-0'to 6-11-4 zone;C-C for
members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1:60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all: areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord'and any other members.
4) Refer to girder(s) for truss to truss connections:
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except at=lb)
3=195, 2=217.
6) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum
sheetrock be applied directly to the bottom chord. '
Thomas A. Alban! PE No.39380
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
bate:
February 20,2020
Q WARNING - Verify deslgn parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev, 10/03/2015 BEFORE USE.
Design valid for use only with MITek® connectors, This design Is. based only upon parameters shown, and is for an Individual building component, not
�-
a.truss system. Before use; the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design, Bracing indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek*
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems,.seeANSVVIII Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd..
Safety Informatlonavallable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type ,
Qty
Ply
LOT 32/1.WATERSTONE
T19470868
2254612
E08
Jack -Partial
10
1
Job Reference (optional)
ounueis n1sr0uurue trrdrn %lily, rLI, MUM Idly, rL - 00001 i C.z4u S reD / zuzu MI I eK InausineS, Inc. I nu reo zu T in in u zuzu rage 1
I D:v3HtyczpYvZt t m?gXrhK6yOc4g-QO6RR7HRFFId_VOcdW g4403HETTkQnW pl wplzj G5d
1-4-0 6-3-7 7-4.2 8-8-0
1-4-0 6-3-7 1-0.9 1-4.0
r
Scale = 1:27.7
3x4
7-4-0
8-8.0
7-4.0
Plate Offsets (X,Y)-- [2:0-2-15;0-0-4]
LOADING (psf)
SPACING-
2-0-0
CS].
DEFL. in
(loc) I/defl Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.64
Vert(LL) 0:14
_ 7-10 >736 240
MT20 244/190
TCDL 7.0
Lumber DOL
1.25
BC 0.44
Vert(CT) -0.20
7-10 >523 180
BCLL 0.0
Rep Stress Incr
. YES
WB 0.30
Horz(CTT) 0.01
2 n/a n/a
BCDL: 10.0
Code FBC2017/TP12014:
Matrix -AS
Weight: 35lb FT=20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.2
TOP CHORD
Structural wood sheathing directly applied.
BOT CHORD 2x4 SP No.2
BOT CHORD
Rigid ceiling directly applied.
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 5=292/Mechanical, 2=396/0-8-0, 6=21/Mechanical
Max Horz 2=330(LC 12)
Max Uplift 5=-189(LC 12), 2=-230(LC 12), 6=-53(LC 12)
Max Grav 5=328(LC 17), 2=396(LC 1), 6=25(LC 17)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-481/374
BOT CHORD 2-7=-643/493
WEBS 4-7- 801/794, 3-7=-761/1005
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=6.Opsf; h=25ft; B=45ft; L=40ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-4-0 to 2-8-0, Intedor(1),2-8-0 to 8-7-4 zone;C-C for
members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) All bearings are assumed to be SYP No.2 crushing capacity of 565 psi.
5) Refer to girder(s) for truss to truss connections...
6) Bearing at joint(s)' 2 considers parallel to grain value using ANSI/fPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6 except Qt=lb)
5=189, 2=230.
8) This truss design requires that a minimum of 7/16".structural wood sheathing be applied directly to the top chord and 1/2" gypsum
sheetrock be applied directly to the bottom chord,.
Thomas A..Albani PE N06360
MiTek USA, ]no. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610 .
Dater
February 20,2020'
0 WARNING -Verily design parameters and READ NOTES ON THIS AND INCLUDED M/TEK REFERANCE PAGE MIP7473 rev. 1010312015 BEFORE USE.
Design valid for use only With MITekO connectors. This design is based only upon parameters.shown, and.ls for an Individual building component, not
a Truss system. Before use; the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek'
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSVFP11 Quality Criteria, DS11.69 and BCSI Building Component
6904 Parke East Blvd.
Safety Infonnatlonovailable from Truss Plate Institute, 218 N. Lee Street, Suite 312; Alexandria, VA 22314. -
Tampa, FL 33610
Job
Truss
Truss Type r
City
Ply
LOT 32/1 WATERSTONE
T19470B69
2254612
EJ08
Jack -Partial
2 •
1
Job Reference (optional)
uuuuc, aiouuicc indrn —ty, IL),- ridrn �ny, rL - 0000r; C.Z4u s reo / zuZU MI I eK Inousrnes, Inc. I nu t-eD ZU 11:11:1 J ZUZU rage l
I D: B R_XOsh7y?ZO Fb_a5k3hZM ypxo W-gboa39J KYAg CrR EbH m3Xci ec9 RQzxmyzdg FaQ3zj G 5a
-1-4-0 4-4-15 8-8-0
1.4.0 4-4-15 4-3-1
Scale = 1:29.4
2x4 11
4
US
- -- 8-6-4 8i8r
m
m
N
O
O
0'
N 7
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
I/dell
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL -
1.25
TC 0.47
Vert(LL)
-0.16
5-8
>644
240
.
MT20 244/190
TCDL 7.0
Lumber DOL
1.25
BC . 0.65
Vert(CT)
-0.32
5-8
>318
180
BCLL 0.0 '
Rep Stress Incr
YES
WB 0.27
HOrz(CT).
0.01
2
n/a
n/a
BCDL 10.0
Code FBC20171 TP12014
Matrix -AS
Weight: 40 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied.
BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied.
WEBS 2x4SP No.3 *Except*
4-5: 2x6 SP No.2
REACTIONS. (lb/size) 2=390/0-8-0, 5=306/Mechanical
Max Harz 2=324(LC 12)
Max Uplift 2=-228(LC 12), 5=-238(LC 12)
Max Grav 2=390(LC 1), 5=346(LC 17)
FORCES. (lb) -Max. Comp./Max: Ten. -All forces 250 (lb) or less except when shown. -
TOP CHORD 2-3=-532/660
BOT CHORD 2-5— 948/558
WEBS 3-5=-535/917
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (37second gust) Vasd=124mph; TCDL=4.2psf; BCDL=6.Opsf; h=25ft; B=45ft; L=40ft; eave=4ft; Cat._
11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Comer(3) -1-4-0 to 2-8-0, Exterior(2) 2-8=0 to 8-5-4 zone; cantilever left
and right exposed ; end vertical left and right exposed;C-C for members and forces & MW FRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and, any other members.
4) Refer to,girder(s) for truss to truss connections.
5) Bearing at joint(s) 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface:
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)
2=228,5=238.
7) This truss design requires that a minimum of7/16" structural wood.sheathing be applied directly,to the top chord and 1/2" gypsum
sheetrock be applied directly to the bottom chord.
Thomas A..Albani PE No.39380
Mi rek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610 . .
Date;
February 20,2020
0 ;WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE Mll-7473 rev. Ma3/2015 BEFORE USE,
- -
Design valid for use only with MiTek® connectors. This design Is based only upon porameters.shown, and,ls for an Individual building component, not
a truss system. Before use; the building designer must verify The applicablllty of design parameters and properly Incorporate this design Into the overall
building design. Bracing indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek''
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the: '
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSVIPII Quality Criteria,.DSB-69 and SCSI Building Component
6904 Parke.East Blvd.
Safety Informationovailoble from Truss Plate Institute, 218 N. Lee Street, Suite 312; Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
04y
Ply
LOT 32/1 WATERSTONE
T19470870
2254612
G01
HIP GIRDER
1
1
Job Reference (optional)
.+unucla , uau�uu, c �r au, .,ny, FI1, nanr uuy, oaoi, 0.i 4U
ID:v3HtyczpYvZlln
-1-4-0 3-9-4 7-0-0 11-11-4
1-4.0 3-9-4 ' 3.2-12 4-11-4
/ ZUZU MI I eK Inauslnes, mc. I nu t-eD ZU 11:1 /:14 ZUZU rage 1
K6yOc4g-InMyHVKylTo3TbpnrTam9wApwrsGgEh6sK?ByW 4 G52
16-0.0 19-0-0 20-4-0
4-0-12 3.0-0 1-4.0.
Scale = 1:36.5
4x6 =
3x4 =
4 21 22 23 5
IG
3x4, = 2x4 11 3x4 = 1.5x8 STP = .
6x8 =
4x8 =
24 6
3-9.4 7.0-0 11-7-10 11r11-4 16.0.0 19-0.0
3-9-4 3-2-12 i 4-7-10 0- - 0 4-0-12 T 3-0-0
LOADING (psf)
'SPACING- 2-0-0
CSI.
DEFL. in (loc) I/defl Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1. 25
TC 0.34
Vert(LL) 0.04 12-13 >999 240
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.26
Vert(CT) -0.05 12-13 >999 180
BCLL 0.0
Rep Stress Incr . NO
WB 0.24.
Horz(CT) 0.01 12 n/a n/a
BCDL. 10.0
Code FBC2017fTP12014
Matrix -MS
Weight: 102 lb FT = 20'/0
LUMBER- BRACING -
TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2x4 SP No.2 'Except' BOT CHORD Rigid ceiling directlyapplied or 6-0-0 oc bracing. . .
10-12: 2x4 SP No.3
WEBS 2x4 SP No.3
REACTIONS. ,(lb/size) 2=552/0-8-0, 7=416/0-3-8, 12=620/0-7-4
Max Harz 2=132(LC 7)'
Max Uplift 2= 401(LC 8), 7==497(LC 8), 12=-610(LC 8)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250.(Ib) or less except when shown.
TOP CHORD 2-3=-788/442, 3-4=-524/365, 4-5=-408/349, 5-6=-444/516, 6-7=-520/535
BOT CHORD 2-14=-385/725, 13-14=-385/725, 12-13=-225/452, 10-12=-397/516, 10-11=-201/404,
9-1 0=- 192/413, 7-9— 380/439
WEBS 3rl3=-336/199, 11-13=-70/278, 5-9=-464/122, 5-10=-344/441,.11-12=-486/254
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust)' Vasd=124mph; TCDL=4.2psf; BCDL=6.Opsf; h=25ft; B=45ft; L=40ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MW FRS (directional); porch right exposed; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding..
4) This truss has been designed for a 10.0 psi bottom chord live load nonconcurrent with any other live loads.
5) This truss has been designed for a live load of 20.Opsf on the.bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between.the bottom chord and. any other members. .
6) All bearings are assumed to be SYP No.2 crushing capacity of 565 psi.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 Ib uplift at joint(s) except at=lb)
2=401, 7=497, 12=610.
8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 6 lb down and 85 lb up at
9-11-4, 6 Ib down and 85 Ib up at 11-11-4, and 6 Ib.down and.85 Ib up at 13-11-4, and 35 lb down and 195 lb up -at 16-0-0 on top
chord,;and 71b down and 54 lb up at. 9-11-4, 7 (b down and 29 lb up at 11-9-8, and 7 lb down and 11 lb up at 13-11-4, and 7 lb
down and 11 lb up at 15-11-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others., .
9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead.+ Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25..
Uniform Loads (plf)
Vert: 1-4=-54, 4-6=-54, 6-8=-54, 12-15= 20, 10-18=-20
Concentrated Loads (lb)
Vert: 6=-3(F)'9=-5(F) 5=-3(F) 12=-7(F) 22=-3(F) 24=-3(F) 25=-7(F) 27=-7(F)
Thomas A. Albani PE No.39360
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Dater
February 20,2020
A.WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCEPAGE 111II-7473 rev. 10/03/2015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and, is for an Individual building component, not
'
a. truss system. Before use; the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek'
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication; storage, delivery, erection and bracing of trusses and truss systems, seeANSVIPII Quality Cdteda, DSB-89'and SCSI Building Component
6904 Parke.East Blvd. ,
Safety Informatlonavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type ,
Oty
Ply
LOT 32/1.WATERSTONE
T19470871
2254612
H3
Diagonal Hip Girder
1
1
Job Reference (optional)
tlullaerS virsibource kviapi filly, t-L), vian1 Lary, VL- - d6b6/, a.Z4u s reD 1 ZUZU MI I eK InausineS, Inc. I nu reD xu 11:1 f:14 ZUZU rage 1-
ID:v3HtyczpYvZl l m?gXrhK6yOc4g-InMyHVKylTo3TbpnrTam9wAglruBgHS6sK?8ywzjG5Z
-1-10-10 4-2-3
1-10-.10 r 4-2-3
1
4-2-3
4-2-3
Scale = 1:12.6 '
LOADING (psf)
. SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
I/defl
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.32
Vert(LL)
0.02
4-7
>999
240
MT20 244/190
TCDL 7.0
Lumber DOL
1.25
BC 0.14
Vert(CT)
-0.02
4-7
>999
180
BCLL 0.0
Rep Stress Incr
NO
WB. 0.00
Horz(CT)
-0.00
3
n/a
n/a
BCDL 10.0
Code FBC2017fTPI2014
Matrix -MP
Weight: 16 lb FT = 20
LUMBER- BRACING -
TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 4-2-3 oc pudins.
BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 3=36/Mechanical, 2=103/0-4.-u, 4=7/Mechanical
Max Horz 2=104(LC 8)
Max Uplift 3=-55(LC 8), 2=-233(LC 8)
Max Grav 3=36(LC 1), 2=103(LC 1), 4=59(LC 3)
FORCES. (lb) -.Max. Comp./Max. Ten.: All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=6.Opsf; h=25ft; B=45ft; L=40ft; eave=6ft; Cat.
11; Exp C; Encl., GCpi=0.18; MW FRS (directional); Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for alive load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide.
will fit between the bottom chord and any other members.
4) Bearings are assumed to. be: Joint 2 SYP No.2 crushing capacity of 565 psi, Joint 4 SYP No.2 crushing capacity of 565 psi.
5) Refer to,girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3 except Gt=1b)
2=233:.
7) Hanger(s)'or other connection device(s) shall be provided sufficient to support concentrated load(s) 3 lb down and 57 lb up at
1-4715, and 3 lb down and 57 lb up at 1-4-15 on top chord, and 18 lb up at 1-4-15, and 18 lb up at 1-4-15 on bottom chord. The
-design/selection of such connection device(s) is the responsibility of others.
8) In the LOAD CASE(S) section, loads applied to the face of the truss. are n.otecl as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plo
Vert:1-2=-54. -
Concentrated'Loads (lb)
Vert: 8=115(F=57, 13=57)
Trapezoidal Loads (plf)
Vert:2=0(F=27, B=27)-to-3=-56(F=-1, B=-1), 5=0(F=10, 13=10)-to-4=-21(F=-0, B=-O)
Thomas A. Alban! PE N6:36380
MiTek USA, Inc. FL Cert 6634
6164 Parke East Blvd. Tampa FL 33616
Dater
February 20,2020
Q WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE 111IF7473 rev. 10/03/2015 BEFORE USE,
Design valid for use only with MfTek® connectors. This design Is, based only upon parameters shown, and Is for an Individual building component, not
a.truss system. Before use; the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing indicated is to, prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek'
Is always required for stability and to prevent collapse with possible personal Injuryand property damage. For general guidance regarding the.*
fabrication, storage; delivery, erection and bracing of trusses and truss systems,.SeeANSVTP11 Quality CLBcrlo, DSB-69 and BCSI Building Component
6904 Parke East Blvd.
Safety Informotlomvailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type r
Oty
Ply
LOT 32/1 WATERSTONE
T1947OB72
2254612
H5
Diagonal Hip Girder
2
1
Job Reference (optional)
tiunaers mrsrsource trtanr uny, ry, manr dory, rl_ - saSbl; a.zau s reo I euzu mi t eK mausrnes, tnc. i nu reo zu i 1:l t:1 o zuzu rage i
ID:v3HtyczpYvZ11 m?gXrhK6yOc4g-m_wKUrLa3nww410_OB5?i7jwpF87PkhF5_khVyzjG5Y
1-10-10 7 0 14
1-10-10 7-0-14
Scale = 1:17.4
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc) .
I/defl
Ud
PLATES' GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.59
Vert(LL)
0.14
4-7
>622
240
MT20 244/190
TCDL 7.0
Lumber DOL
1.25
BC 0.54
Vert(CT)
-0.20_
4-7
>411
180
BCLL 0.0
Rep Stress Incr
NO
WB. 0.00
Horz(CT).
_
-0.00
3
n/a
n/a
BCDL 10.0
Code FBC2017ITP12014
Matrix -MP
Weight: 25 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc. purlins.
BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 3=187/Mechanical, 2=181/0-11-5, 4=85/Mechanical
Max Horz 2=196(LC 8)
Max Uplift 3=-212(LC 8), 2=-225(LC 8)
Max Gram 3=187(LC 1), 2=181(LC,1),4=139(LC 3)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASIDE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; B=45ft; L=40ft; eave=6ft; Cat.
Il; Exp C; Encl., GCpi=0.18; MW FRS (directional); Lumber D6L=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has.been designed for a live, load of 20.Opsf on the bottom chord inall areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members. :
4) Bearings are assumed to be: Joint 2 SYP No.2 crushing capacity of 565 psi, Joint 4 SYP No:2 crushing capacity, of 565 psi.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except at=lb)
3=212, 2=225.
7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 3 lb down and 57 lb up at
1-5-12, 3 lb down and 57 lb up at .1-5-12, and 3 lb down.and 77 lb up at 4-3-11, and 3.Ib down and 77 lb up at -4-3-1.1 on top chord,
and 1 lb down and 5 lb up at 1-5-12, 1 lb down and 5 lb up at 1-5-12, and 4 lb down at 4-3-11, and 4 lb down at 4-3-11 on bottom
chord., The design/selection of such connection device(s) is the responsibility of others.
8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD.CASE(S) Standard.
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Veit: 1-2=-54
Concentrated Loads (lb)
Vert: 8=115(F=57, B=57) 11=-7(F_ 4, B= 4)
Trapezoidal Loads (plf)
Vert: 2=0(F=27, 6=27)-to-3= 95(F= 21, B=-21), 5=0(F=10, B=10)-to-4=-35(F=-8, B=-8)
Thomas A. Alban! PE No:39380
MiTek USA; Inc. FL Cert 6634
6104 Parke East Blvd. Tampa FL 33610
bate:'
February 20,2020
Q ,WARNING - Verity design parameters and READ NOTES ONTHIS AND INCLUDED MITEK REFERANCE PAGE MIP7473 rev. 1010312015 BEFORE USE.
Design valid for use only with Mlrek® connectors. This design is. based only upon parameters shown, and, Is for an Individual building component, not
a truss system. Before use, the building designer must verity the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek''
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage; delivery, erection and bracing of trusses and truss systems, seeANSVrPII Quality Cdlerla,.DSB-69'and SCSI Building Component
6904 Parke East Blvd..
Safety Infonnatlonavoilable from Truss Plate Institute, 2.18 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type •
Oty .
Ply
LOT 32/1. WATERSTONE
T19470873
2254612
H5P
Diagonal Hip Girder
2
1
Job Reference (optional)
oul)uC)S n)310VU,UU tr)dl)l 111y, rL), r)dr)l idly, rL - 00001, Mee S rep i zuzu MI I ex mousines, Inc. I nu reD zu l l:l inia vu2U rage T
ID:nl6t6khBsl5X3GHCY16ml Mya6Fs-FAUjhBMCg52nivzAyudEELG27fO287?PKeUF10zjG5X
1-10-10 3-B-10 7-0-2
1-10-10 3-8-10 3-3-8
Scale = 1:17.3
7.0-2
� 7-0-2
PIatP OffSPts fX YI-- r9-n-n-Fi.n-n.qi
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc):
I/defl
Ud
PLATES GRIP
TCLL ' 20:0
Plate Grip DOL
1.25
TC 0:81
Vert(LL)
0.27
6-9
>306
240
MT20 244/190
TCDL 7.0
Lumber DOL
1.25
BC 6.94
Vert(CT)
0.23
6-9
>357
.180
BCLL 0.0 '
Rep Stress Incr
NO
WB 0.32
Horz(CT)
-0.01
6
n/a
n/a
BCDL. 10.0
Code F.BC2017/TPI2014
Matrix -AS
Weight: 30lb FT=20%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied.
BOT CHORD. 2x4 SP No.2 BOT CHORD Rigid ceiling directly.applied.
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 4=64/Mechanical, 2=373/0-4-9, 6=180/Mechanical
Max Horz 2=215(LC 12)
Max Uplift 4=-72(LC 12), 2=-451(LC 12), 6= 225(LC 12)
Max Grav 4=73(LC 17), 2=373(LC 1), 6=185(LC 3)
FORCES. (lb) - Max. Comp:/Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-326l742
BOT CHORD 2-6=-979/325
WEBS 3-6=-353/1063
NOTES-
1) Wind: ASIDE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=6.Opsf; h=25ft; B=45ft; L=40ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Comer(3)-1-10-10 to 3-8-10, Exterior(2) 378-10 to 6-11-6 zone; porch left
exposed;C-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip'DOL=1.60
2) This truss:has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for alive load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0.tall by 2-0-0 wide
will fit between the bottom.chord and any other members.
4) All bearings are assumed to be SYP No.2 crushing capacity of 565 psi.
5) Refer to girder(s) for' truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100'lb upliftat joint(s) 4 except Qt=lb),
2=45116=225
7) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum
sheetrock be applied directly to the bottom chord.
Thomas A. Alban! PE N6'39360
MiTek USA, Inc. FL Cert 6634
6104 Parke East Blvd. Tampa FL 33610
Date:
February 20,2020
Q WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MrTEK REFERANCE PAGE MII.7473 rev. 10/03/2015 BEFORE USE.��
Design valid for use only with MITek® connectors. This design Is. based only upon parameters shown, and Is for an Individual building component, not
a.truss system. Before use; the building designer must verify the applicablllty of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated is to. prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
r►
MITek'
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the - ..
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSVTPIt Quo' H►tyy Cdterlo, DSB-89'and SCSI BuBding Component
6904 Parke.East Blvd..
Safety Inlormatlonavallable from Truss Plate Institute, 218 N. Lee Street, Suite 312,- Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type I
.Qty
Ply
LOT 32/1 WATERSTONE
T19470874
2254612
H7
Diagonal Hip Girder
2
1
Job Reference (optional) .
tsunuers rirsrxsource triam t ny, ref; riarn k,ny, rr- - 30ao1, u.zvu s rqD r zuzu rvu i eK mausmes, nc. r nu reu zu r r: r t: r r zuzu rage i
ID:sKKHvj4Ck9imdNUr8t11Gt4 GwT-j M 15vXMgbOAeK3YM W b8TnYolw3rptZKYYIDoZrzj G5W
-1-10-10 5-2-5 9.10-13
1-10-10 5-2-5 4-8-7
Scale=1:23.0
NAILED . NAILED NAILED 3x4 =
5-2-5
525
9-10-13
48-7
Plate Offsets (X,Y)--
[2:0-2-11,0-0 31
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)_
I/defl
Ud
PLATES _ GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.49
Vert(LL)
' -0.07
7-10
>999
240
MT20 244/190
TCDL 7.0
Lumber DOL
1.25
BC 0.46
Vert(CT)
-0.08
7-10
>999
180
BCLL 0.0 '
Rep Stress Incr
NO
WB 0.38
Horz(CT)
0.01
5
n/a
n/a
BCDL 10.0
Code FBC2017/TP12014,
Matrix -MS
Weight: 43lb FT=20%
LUMBER -
TOP CHORD
2x4 SP No.2
BOT CHORD
2x4 SP No.2
WEBS
2x4-SP No.3
REACTIONS.
(lb/size) 4=124/Mechanical, 2=517/0-8-0, 5=330/Mechanical
Max Horz 2=278(LC 24)
Max Uplift 4=-154(LC 8), 2= 244(LC 8), 5= 112(LC 8)
Max Grav 4=124(LC 1),'2=517(LC 1), 5=354(LC 28)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD
2-3= 872/240
BOT CHORD
2-7=-334756, 6-7=-334/756
WEBS
3-7=0/286, 3-6=-820/363
BRACING -
TOP CHORD Structural wood sheathing directly applied or 5-7-5 oc pudins.
BOT CHORD Rigid ceiling directly applied or 9-8-11 oc bracing. .
NOTES.. .
1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=6.Opsf; h=25ft; B=45ft; L=40ft; eave=5ft; Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS,(directional); Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a'rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb)
4=154, 2=244, 5=1.12:
6) "NAILED" indicates 3-1 Od (0.148"x3") or 2-12d.(0.148"x3.25") toe -nails per NDS guidlines.
7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Unifoml Loads (plf)
Vert: 1-4==54, 5-8=-20
Concentrated Loads (lb)
Vert: 13=-75(F=-37, B=-37) 15=-10(F= 5, B=-5) 16=-57(F=-28, B=-28)
Thomas A. Albani PE Nti:39380
MiTek USA, Ind. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
February 20,2020
Q WARNING - Verily design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE Mil- 7473 rev. 10/=015 BEFORE USE.
Design valld for use only with MiTek® connectors. This design Is. based only upon parameters shown, and, Is for an Individual building component, not
a.truss system. Before use; the building designer must verity the applicability of design parameters and properly Incorporate this design into the overall
building design, Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek'
Is always required for stability and To prevent collapse.with possible personal InJury.and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSIM11 Quality Criteria, DS111-89 and BCSI Building Component
6904 Parke.East Blvd.
Safety Infonnationavollable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type 1 c +..Oty
Ply
LOT 32/1 WATERSTONE
T19470875
2254612
H7V
Diagonal Hip Girder
2
1
Job Reference (optional)
ouuuers rnslaource (want udry, rL), riani L ny, rL - JdObf, U.24U S reD / xuxu MI I eK Inaustrles, Inc. I nu reo zu 11:11:11 zuzu rage 1
ID:v3HtyczpYvZ11 m?gXrhK6yOc4g-jM15vXMgbOAeK3YMWb8TnYoEU3vitVAYYIDoZrzjG5W
-1-10-10 7-9-12 12-2-5 12 -1
1-loco 7-9-12 4-4-9 0- -12
Scale = 1:29.0
2x4 l l
4 5
0
4.24 F12 3x4
.3 ai
N
... 5x� II O o
7. o 6
a ._
:2x4
.2
9 z,iz 12
3x4 =
12.3.1
.. 7-9-12 12-2-5 12�-7
7-9-12 4-4-9 0- 2
0-0-10
Plate -Offsets (X,Y)-- [6:0-2-8,0-2-4]
LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft . Ud PLATES GRIP
TCLL 20.0 Plate Grip DOL 1.25 TC -0.71 Vert(LL) 0.09 7-10 >999 240 MT20 244/190
TCDL 7.0 Lumber DOL 1.25 BC . 0.25 Vert(CT) 0.14 7-10 >999 180
BCLL 0.0 Rep Stress Incr NO WB 0.58 Horz(CT) -0.02 6 n/a n/a
BCDL: 10.0 Code FBC2017/TP12014. Matrix -MS p Weight: 53lb FT=20%
LUMBER- BRACING-
TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 4-0-1 oc purlins.
BOT CHORD 2x4 SP M 31 BOT CHORD Rigid ceiling directly applied or 7-3-15 oc bracing. -
WEBS 2x4 SP No.3 *Except*
4-6: 2x6 SP No.2
REACTIONS. ,(Ib/size) 2=566/0-10-3, 6=909/Mechanical
Max Harz 2=495(LC 8)
Max. Uplift 2=-325(LC 8), 6=-680(LC 8)
Max Grav 2=566(LC 1), 6=1069(LC 13)
FORCES. (lb) - Max. Comp./Max: Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3- 1722/763
BOT CHORD 2-7=-1104/1743, 6-7=-1121/1750
WEBS 3-7=0/336, 3-6=-1725/1099, 4-6=-331/317
NOTES-
1) Wind: ASIDE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=6.opsf; h=25ft; B=45ft; L=40ft; eave=6ft; Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS'(directional); Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ` This truss has been designed for alive load of 20.Opsf on.the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Bearings are assumed to be: Joint 2 SYP No.2 crushing capacity of 565 psi.
5) Refer to girder(s) for truss to truss connections.
6) Bearing at joint(s) 2 considers parallel to grain value using ANSI/T-PI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
7) 'Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except at=lb)
2=825, 6=680.
8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASES) Standard
1) Dead.+ Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plo
Vert: 1-2=-54, .4-5=-14
Trapezoidal Loads (plf)
Vert:2=0(F=27, B=27)-to-4=-169(F= 57; B=-57), 8=0(F=10; B=10)-to-6=-61(F=-21, B=-21)
Thomas A. Alban! PE No:39380
MlTek USA, Inc. FL Cart 6634
6104 Parke East Blvd. Tampa FL 33610
bate:
February 20,2020
Q WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MrrEK REFERANCE PAGE MII-7473 rev. 1010312015 BEFORE USE.
-
Design valid for use only with MITek® connectors. This design is. based only upon parameters shown, and, Is for an Individual building component, not�
a.truss system. Before use; the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design, Bracing Indicated Is to, prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
M iTek'
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication; storage; delivery, erection and bracing of trusses and truss systems, seeANSVTPII Quality Criteria,.DSB-89 and SCSI BuOding Component
6904 Parke East Blvd.
Safety Informationavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type >
oty
Ply
LOT 3211 WATERSTONE
T19470876
2254612
K01.
Common
1
1
Job Reference (optional)
trullaers rlrsibource trlant Gny, rL), rlani Guy, rL - JJpbr; ts.Z4u S YeD / Zuzu MI I eK Inausirles, Inc. I nu reo zu 1 in in t5 zuzu rage 1
ID:v3HtyczpYvZ11 m?gXrhK6yOc4g-BZbT6sNSMilVxC6Z4JfrJmLUGSB9c4sinyzL6HziG5V
-1-4-0 6-0-0 11-11-4
1 4 0 i 6-0.0 i 5-11-4
4x6 = Scale = 1:23.0
3
3x4 = 3x4 =
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc) .
I/defl
Ud
:PLATES. GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.45
Vert(LL)
0.06
5-8
>999
240
MT20 244/190
TCDL 7.0
Lumber DOL
1.25
BC 0.39
Vert(CT)
-0.07
5-8
>999
180
BCLL 0.0 '
Rep Stress Incr
YES
WB 0.10
Horz(CT)
0.01
4
n/a
n/a
BCDL. 10.0
Code FBC2017/TP12014
Matrix -AS
Weight: 44 lb FT = 20%,
LUMBER- BRACING -
TOP CHORD 2x4 SP No.2 TOP CHORD 'Structural wood sheathing directly applied.
BOT CHORD. 2x4 SP No.2 BOT CHORD Rigid ceiling directlyapplied.
WEBS 2x4 SP.No.3
REACTIONS. (lb/size) 4=438/0-7-4, 2=518/0-8-0
Max Horz 2=144(LC 11)
Max Uplift 4=-241(LC 12), 2=-371(LC 12)
FORCES. (lb) -Max. Comp:/Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-623/535, 3-4=-609/559
BOT CHORD 2-5=-349/5061 4-5=-349/506
WEBS 3-5= 22/266
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=6.Opsf; h=25ft; B=45ft; L=40ft; eave=6ft; Cat.
11; Exp C,; Encl., GCpi=0.18; MW FRS (directional) and C-C Exterior(2) -1-4-0 to 2-8-0, Interior(1) 2-8-0 to 6-0-0, Extedor(2) 6-0-0 to
10-0-0, Interior(1) 10-0-0 to 11-11-4 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) This truss has been designed fora 10.0 psf bottom chord live load nonconcurrent with any. other live loads:
4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
5) All bearings are assumed to be SYP.No.2 crushing capacity of 565 psi.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 Ib uplift at joint(s) except Qt=lb);
4=241, 2=371.
7) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum
sheetrock be applied directly to the bottom chord.
Thomas A. Albani PE No:39380
MiTek USA, Inc. FL Cert6634
6904 Parke East Blvd. Tampa FL 33610
Date:'
February 20,2020
;WARNING -Verify design parameters and READ NOTES ON -THIS AND INCLUDED MITEK REFERANCE PAGE M11-7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MRek® connectors. This design Is based only upon parameters shown, and is for an Individual building component, not
a.truss system. Before use; the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek'
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
-
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSIMIt Quality Criteria, DSB-89 and SCSI BuBding Component
6904 Parke. East Blvd.
Safety Intonnatlonavallabie from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type e . '•
Qty
Ply
LOT 32/1 WATERSTONE
T19470877
2254612
K02
HIP GIRDER
1
1
1720E
Job Reference (optional)
tsuucers rustoource triant Lary, ruf, ream Lary, ru - 000bf,
r
1-4.0
LOADING (psf)
TCLL 20.0
TCDL 7.0
BCLL 0.0
BCDL 10.0
5-0-0
4x6 =
3
2-0-0
tl.zvu s reo 1 zuzu Mr r eK maustnes, mc. i nu reo zu i i:i rta zuzu rage -i
ID:v3HtyczpYvZ11 m?gXrhK6yOc4g-Fl9rKC04700MZMhldOAxszugfsX7LXCrOcivejzjG5L
12-0-0 1 13-4-0
4x6 =
4
5-0.0
3x4 = 3x4 =
5-0-0
7.0-0
12-0.0
5.0.0
2-0-0
5-0.0
SPACING-
2-0-0.
CSI.
DEFL.
in
(loc)
I/defl
Ud
PLATES
Plate Grip DOL
1.25
TC 0.34
Vert(LL)
0.08
7-14
>999
240
MT20
Lumber DOL
1.25
BC 0.41
Vert(CT)
-0.09
7-14
>999
180
Rep Stress Incr
NO
WB 6.10
Horz(CT)
0.01
5
n/a
n/a
Code FBC2b17/TPI2014
Matrix -MS
Weight: 49lb
Scale: 1/2°=1'
GRIP
244/190
FT = 20%
T
V
O.
m
o -
CV
LUMBER- BRACING -
TOP CHORD 2x4 SP-No.2 TOP CHORD Structural wood sheathing directly applied or 5-4-15 oc pudins.
BOT CHORD 2x4 SP No.2 BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 2x4 SP No.3
REACTIONS. (lb/size), 2=676/0-8-0, 5=693/0-8-0
Max Harz 2=-131(LC 6)
Max Uplift 2=-453(LC 8), 5=-475(LC 8)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-1001/540, 3-4=-858/539, 4-5=-1.007/547
BOT CHORD 2-8=-321/847, 7-8=-321/85815-7= 327/852
WEBS 3-8=-37/251
NOTES- .
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; 8CDL=6.Opsf; h=25ft; B=45ft; L=40ft; eave=6ft; Cat.
ll; Exp C; Encl., GCpi=0.18; MW FRS (directional); Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ' This truss has been designed for alive load of 20.Opsf on the bottom chord in all areas where a. rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other -members.
6) All bearings are assumed to be SYP No.2 crushing capacity of 565 psi.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except at=lb)
2=453, 5=475.
8) Hanger(s) or other connection device(S) shall. be provided sufficient to support concentrated loads) 66 lb down and 145 lb up at
5-0-0, and 199 Ib down and 384 lb up at 7-0-0 on top chord, and 99 Ib down at 5-0-0, and 99 lb down at 6-11-4 on bottom chord.
The design/selection of such connection device(s) is the responsibility of others.
0) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=125.
Uniform Loads (plf)
Vert: 1-3=-54, 3-4=-54, 4-6= 54, 9-12= 20
Concentrated Loads (lb)
Vert: 3=-47(F) 4=-152(F) 8=-69(F) 7=-69(F)
Thomas A. Alban! PE No.39380
MiTek USA, Inc. FL Cett6634
6904 Parke East Blvd. Tampa FL 33610
Date:
February 20,2020
Q .WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED M/TEK REFERANCEPAGE MII.7473 rev. f0/03/P015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is, based only upon parameters shown, and. Is for an individual building component, not
a truss system. Before use; the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek'
Is always required for stability and to prevent collapse with possible personal Injuryand property damage. For general guidance regarding the
fabrication, storage; delivery, erection and bracing of trusses and truss systems, seeANSVWII Quality Criteria, DSB-89 and BCSI BuOding Component
6904 Parke East Blvd.
SafNy Infonmatlonavollabie from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type ,
Qlty
Ply
LOT 32/1 WATERSTONE
T19470878
2254612
L07
Hip Girder
1
1
Job Reference optional)
t5unuers rlrsxDource trlani Gliy, rL), manl Gay, rL - ddbbf, b.z4y s reo t zuzu MI I ex InausineS, Inc. I nu reo zu i 1:l t:zu zuzu rage 1
ID:QjLiY 9RvfJMNHGeC3aPngyA-1R-7xjDXYPjuJYDBWGxBkhAPBQkrGam4v9?EGSSAAzjG5T
-1-4-0 5.0-0 10.0-0 15.0-0 20-0-0 21-4-0
1-4-0 ' 5-0-0 ' 5-0-1 5.0-0 5.0-0 1-4.0
Special .
4x6 = .
NAILED
3 18
NAILED Special •
NAILED .3xB NAILED 4x6 =
19 4 20 21 5
Scale = 1:36.9
3x4 —_ 3x4 = NAILED 4x6 = . 2x4 II' NAILED 3x4 — 3x4 =
NAILED
Special NAILED Special
20-0-0
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL. in
(loc) I/defl Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TIC 0:83
Vert(LL) 0.29
9-11 >826 240
MT20 244/190
TCDL 7.0
Lumber DOL
1.25
BC . 0.76
Vert(CT) 0.23
9-11 >999 180
BCLL 0.0
Rep Stress [nor
NO
WB 0.43
Horz(CT) -0.10
6 n/a n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix -MS
Weight:91 lb FT=20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.2
TOP CHORD
Structural wood sheathing directly applied or 3-7-14 oc puriins.
BOT CHORD 2x4 SP No.2
BOT CHORD
Rigid ceiling directly applied or 3-3-14 oc bracing.
WEBS 2x4SP.No.3
REACTIONS. (lb/size) 2=1249/0-3-8, 6=1246/0-3-8
Max Horz 2=131(LC 24)
Max Uplift 2=-1335(LC 8), 6=-1330(LC 8)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-2253/2463, 3-4=-1997/2291, 4-5= 1991/2281, 5-6=-2247/2451
BOT CHORD 2-11=-2075/1965, 9-11=-2824/2622, 8-9=-2824/2622, 6-8= 2042/1960
WEBS 3-11=-608/583, 4-11=-753/853, 4-9= 204/314, 4-8= 760/867, 5-8=-608/582
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=6.Opsf; h=25ft; B=45ft; L=4011; eave=5ft; Cat.
11; Exp C; Encl., GCpi=0.18; MW FRS (directional); Lumber DOL=1.60 plate.grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except at=lb)
2=1335, 6=1330.
7) "NAILED" indicates 3-1Od (0.148"x3") or 3-12d.(0.148"x3.25") toe -nails. per NDS guidlines.
8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 221 lb down and 401 lb up at
5-0-0, and 221 lb down and 400 lb up at 15-0-0 on top chord, and 107 lb down and 234 lb up, at 5-0-0, and 107 lb down and 234 lb
up at 14-10-15 on bottom chord. The design/selection of such connection device(s) is the responsibility of others.
9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plo .
Vert: 1-3=-54, 3-5=-54, 5-7=-54, 12-15= 20
Concentrated.Loads (lb)
Vert:3=-154(B) 5_ 154(B) 11=-83(B) 8=-83(B) 18=-61(B) 19=-61(13) 20=-61(B) 21=-61(B) 22=-38(B):23=-38(B) 24=-38(B)
25=-38(B)
Thomas A. Albani PE N6.39380
MiTek USA, Inc. FL Cert 6634
6164 Parke East Blvd. Tampa FL 31816
... Date:
February 20,2020
0 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED M1TEK REFERANCE PAGE M11-7473 rev. 10/03/2015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek'
Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the. . .
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSViPit Quality CrBerla, DS9.89 and BCSI BuAding Component"
6904 Parke East Blvd.
Safoty Infonnationavallable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type y i +
My I
Ply
LOT 32/1 WATERSTONE
T19470879
2254612
L08
Hip
1
1
Job Reference (optional)
Bullders FirstSource (Plant Glty, FL), I'lant Glty, I-L - 33567, U.240 s reD t ZUZU Mi I eK Inaustnes, Inc. I nu Feo zu 11:1 f:zi zuzu rage T
ID:Qj LiY_9RvfJMNHGeC3aPngyA—pR-b8Hcl uQLfdg3pgr71 RCPxOzxegCPpQ?8TwBOic4G5S
1-4-0 7-0-0 13-0.0 20-0-0 21-4-0 ,
1-4.0 7-0.0 6.0-0 7-0.0 1-4-0
Scale=1:36.9
4x10 MT20HS =
5x6 =
3 18 19 20 214
m
m.
3x4 =
3x4 = 2x4 11 3x4 = 3x4
13.0-0 20-0.0
6-0-0 7-0-0
Plate Offsets (X,Y)--
[3:0-6-8,071-121, [4:0-3-8,0-2-4] . .
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in
(loc)
' I/dell
Ud
PLATES
GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.63
Vert(LL)
0.13
7-15
>999
240
MT20
244/190
TCDL 7.0
Lumber DOL . 1.25
BC 0.48
Vert(CT)
-0.16
9-12
>999
180
MT20HS
187/143
BCLL 0.0
Rep Stress Incr YES
WB 0.14
Horz(CT)
0.03
5
n/a
n/a
BCDL. 10.0
Code FBC2017/TP12014
Matrix -AS
Weight: 86 lb
FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied.
BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly, applied.
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 2=812/0-3-8, 5=812/0-3-8
Max Horz 2=-172(LC 10)
Max Uplift 2=-531(LC 12), 5=-531(LC 12)
FORCES. (lb) -Max. Comp:/Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-1171/908, 3-4=-1004/941, 4-5=-1172/907
BOT CHORD 2-9=-601/999, 7-9— 600/1005, 5-7= 621/998
WEBS 3-9=0/263, 4-7=0/263
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASIDE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=6.Opsf; h=25ft; B=45ft; L=40ft; eave=5ft; Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-4-0 to 2-8-0, Interior(1) 2-8-0 to 7-0-0, Exterior(2) 7-0-0 to
12-7-14, Intetior(1)12-7-14 to 13-0-0, Exterior(2),13-0-0 to 18-7-14, Interior(1) 18-7-14 to 21-4-0 zone;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to.prevent water ponding.
4) All plates are MT20 plates unless.otherwise indicated.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) ' This truss has been designed for a live load of-20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2=0-0 wide
will fit between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb)
2=531, 5=531.
8) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum
sheetrock be applied directly to the bottom chord.
Thomas A. Alban! PE No.39380
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Dater
February 20,2020
0 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCEPAGE 11411-7473 rev. 101032015 BEFORE USE.
Design valid for use only with MITek® connectors. This design Is based only upon parameters.shown, and Is for an Individual building component, not
a. truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek'
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the .
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSVTPII Quality Cdtedo, DSB-89 and III Bullding Component
6904 Parke,East Blvd.
Safoty Infonnationovallable from Truss Plate Institute, 218 N. Lee Street, Suite 312; Alexandria, VA 22314.
Tampa, FL 33610 -
Job
Truss
Truss Type < '
ty
Ply
LOT 32/1 WATERSTONE
T19470880
2254612
L09
Hip
1
1
Job Reference (optional)
-,uuuo uawuww tr ion —1y, r h ntll Il l Ly, rL - OODV/, o.e,+u s reu I ZUZU IVII I eK Inuusuies, Inc. r nu rea zu I I:1 r:ZZ zuzu rage i
I D:gLiY_9RvfJMNHGeC3aPngyA_pR-3Kr_yEQzQxpwQgQKJgjfUcW 9f4VIYtEHiaxZF2zjG5R
1-4.0 6-3.6 9-0-0 11-0.0 13-8-10 20-0-0 21-4-0
1-4-0 ' 6-3.6 2-6-10 2-0-0 2-8-10 6-3-6 1-4-0
Scale = 1:36.9
4x6
4x6 =
:4 5
IIl
3x6 = I I-
3x4 = 4x6 = 3x4 =
3x6 =
9.0.0 11-0-0 20-0-0
9-0.0 2.0-0 9-0-0
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in (lac.) I/defl Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.42
Vert(LL) -0.14 11-14 >999 240
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0:67
Vert(CT) -0.31 11-14 >779 180
-
BCLL 0.0 '
Rep Stress Incr YES
WB. 0.14
Horz(CT) 0.03 7 n/a n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix -AS
Weight: 92 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied.
BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied.
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 2=812/0-3-8, 7=812/0-3-8 -
Max Horz 2=-213(LC 10)
Max Uplift 2=-531(LC 12), 7= 531(LC 12)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-1182/914„3-4=-971/790,4-5=-823/736,5-6=-971/790,6-7=-1182/914
BOT CHORD 2-11=-647/1055, 9-11=-351/823, 7-9=-668/1023
WEBS 3-11=-380/473, 4-11=-265/362, 5-9==265/363, 6-9=-381/472
NOTES -
I) Unbalanced roof live loads have been considered for this design. .
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=6.Opsf; h=25ft; B=45ft; L=40ft; eave=5ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-4-0 to 2-8-0, Interior(1) 2-8-0 to 9-0-0, Extedor(2) 9-0-0 to
16-7-14, Interior(1) 16-7-14 to 21=4-0 zone;C-C for members and forces. & MWFRS for reactions shown; Lumber DOL=1.60 plate,
grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed .for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ' This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-6 wide
will fit between the bottom chord and any other members.
6) Provide mechanical Connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=1b)
2=531, 7=531.
7) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum
sheetrock be applied directly to the bottom chord.
Thomas A. Albani PE No:39380
MiTek USA, Inc. FL Cert 6634
6964 Parke East Blvd. Tampa FL 33610
Date:
..
February 20,2020
Q WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MIP7473 rev. 10/03/2015 BEFORE USE
Design valid for use only with MITeke connectors. This design Is, based only upon parameters.shown, and Is for an Individual building component, not
��
a.truss system. Before use; the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
MI lT
ek'
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication; storage, delivery, erection and bracing of trusses and truss systems, see/WSVrPl1 CualB�yy CrIterlo, DSB49 and SCSI Bulldtng Component
6904 Parke East Blvd.,
Safety Infonnationavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312; Alexandria, VA 22314.
Tampa, FL 33610
Symbols..
PLATE LOCATION AND ORIENTATION
3/4 Center plate on joint unless x, y
Offsets are indicated. -
Dimensions are in ft-in-sixteenths.
Apply plates to both sides of truss
and fully embed teeth.
I "
For 4 x 2 orientation, locate
plates 0=1hb" from outside
edge of truss.
Numbering System.
6-4-8. dimensions shown in ft-in-sixteenths
(Drawings not scale)
1 2 - . 3
BOTTOM CHORDS
8 7 6 5
This symbol indicates the
JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE
required direction of slots in
AROUND THE TRUSS. STARTING AT THE JOINT FARTHEST TO
connector plates.
THE LEFT.
Pk7te location details available in MTek 20/20 -
CHORDS AND WEBS ARE IDENTIFIED BY END JOINT
NUMBERSAETTERS.
software or upon request..
PLATE SIZE-
PRODUCT CODE APPROVALS
ICC-ES Reports:
The first dimension is the plate
4 x 4 width measured perpendicular
ESR-1311, ESR-1352, ESR1988
to slots. Second dimension is
ER-3907, ESR-2362, ESR-1397, ESR-3282
the length parallel to slots.
LATERAL BRACING LOCATION
Indicated by symbol shown and/or
by text in the bracing section of the
output. Use T or I bracing
if indicated.
BEARING
Indicates location where bearings
(supports) occur. Icons vary but
reaction section indicates joint
number where bearings occur.
Min size shown is for crushing only.
Industry Standards:
ANSI/TPI I: National Design Specification for Metal
Plate. Connected Wood Truss Construction.
DSB-89: Design Standard for Bracing,
BCSI:. Building Component Safety Information,
Guide to Good Practice for Handling,
Installing & Bracing of Metal Plate
Connected Wood Trusses.
Trusses are designed for wind loads in the plane of the .
truss unless otherwise shown.
Lumber design values are in accordance. with ANSI/TPI 1
section 6.3 These truss designs rely on lumber values
established by others.
2012 MiTekO All Rights Reserved
1a
MiTek.
MiTek Engineering Reference Sheet: Mll-7473 rev. 10/03/2015
General Safety Notes
Failure to Follow Could Cause Property
Damage or Personal Injury
1.. Additional stability bracing for truss system, e.g.
diagonal or X-bracing, is always required. See BCSI.
2. Truss bracing must be designed. by an engineer. For
wide truss spacing; individual lateral braces themselves
may require bracing, or alternative Tor I
bracing should be considered.
3. Never exceed the design loading shown and never
stack materials on inadequately braced trusses.
4.. Provide copies of this truss design to the building
designer, erection supervisor, property owner and
all other interested parties.
5. Cut members to bear tightly against each other.
6. Place plates on each face of truss at each
joint and embed fully. Knots and wane at joint
locations are regulated by ANSI/TPI 1.
7. Design assumes trusses will be suitably protected from
. the environment in accord with ANSI/TPI 1.
8. Unless otherwise noted, moisture content of lumber
shall not exceed 19%at time of fabrication.
9. Unless expressly noted, this design is not applicable for
use with fire retardant, preservative treated, or green lumber..
10. Camber is a non-structural consideration and is the
responsibility of truss fabricator. General practice is to
camber for dead load deflection.
11. Plate type, size, orientationand location dimensions
indicated are minimum plating requirements.
12. Lumber used shall be of the species and size, and
in all respects, equal to or better than that
specified.
13, Top chords must be sheathed or purlins provided at
spacing indicated on design.
14. Bottom chords require lateral bracing at 10 ft. spacing,
or less, if no ceiling is installed, unless otherwise noted.
15. Connections not shown are the responsibility of others.
16. Do not.cuf or alter truss member or plate without prior
approval of an engineer.
17. Install and load vertically unless indicated otherwise.
18. Use of green or treated lumber may pose unacceptable
environmental, health or performance risks. Consult with
project engineer before use.
19. Review all portions of this design (front, back, words
and pictures) before:use. Reviewing pictures alone
is not sufficient.
2.0. Design assumes manufacture in accordance with
ANSI/TPI 1 Quality Criteria.