HomeMy WebLinkAboutBuilding Plans9.101 21'-0" 5'-6" WATER LINE S-I4" 1 5'-0" 11 ° SLOPE 1 <- MAX. (TYP.) 7 �1 3 MAX. MAIN DRAIN LOCATION LONGITUDINAL POOL SECTION 11 ° SLOPE MAX. (TYP.) N.T.S. Determine Minimum System Flow Rate: (35 gpm per Skimmer) 1. Pool Volume Calculation: 356 ft2 (Surf Area) , 3.3 ft (Avg. Depth) x 7.48 _ gal/ft3 = 8,788gal 2. Determine Flow Rate: 8,788 gal" 360min = 24.40973_ gpm + 0 gpm = 24.41 gpm (Volume) (Turnover Time) (Pool Flow) (Feature Flow) (System Flow) 3. Determine Pipe Sizes: Trunk Piping to be 25' to keep velocity at 8fps max, at 117 gpm Maximum System Flow Rate Return Piping to be 2.0" to keep velocity at 8fps max. at 82 gpm Maximum System Flow Rate System Flow Rate Must Not Exceed Flow. Rate for Main Drain Cover (See Detail at Right) Pump Model: FHPVSI.O H.P.: 1.0HP Total H.P. = H.P. x service factor. 1 H.P. or more must be 2 speed or variable speed. Filter Make: CS 100 Size: 100 Filter min. area based on 6 hr turnover flow rate (pool flow rate calculated above) Divide gpm by the following factors: Cartridge - 0.375, Sand -15 or D.E. - 2 Time Controller Make: Intermatic Model: PE 35300 POOL EQUIPMENT Determine Minimum System Flow Rate: (35 gpm per Skimmer) 1. Pool Volume Calculation: 49 ft2 (Surf Area) ; 3 ft (Avg. Depth) x 7.48 gal/ft3 = 1,100 gal 2. Determine Flow Rate: 1,100 gal / 360 min = 3.054333 gpm + 0 gpm = 3.0543 gpm (Volume) (Turnover Time) (Pool Flow) (Feature Flow) (System Flow) 3. Determine Pipe Sizes: Trunk Piping to be 2.5" to keep velocity at 8fps max. at 117 gpm Maximum System Flow Rate Return Piping to be 2.5" to keep velocity at 8fps max. at 117 gpm Maximum System Flow Rate System Flow Rate Must Not Exceed Flow Rate for Main Drain Cover (See Detail at Right) Pump Model: FHPM1.5 Total H.P. = H.P. x service factor. 1 H.P. or more must be 2 speed or variable speed. Filter Make: 0 Size: 0 Filter min. area based on 6 hr turnover flow rate (pool flow rate calculated above) Divide gpm by the following factors: Cartridge - 0.375, Sand - 15 or D.E. - 2 Time Controller Make: Intermatic Model: PE 35300 SPA EQUIPMENT POOL RETURN PIPING POOL TRUNK PIPING SPA RETURN PIPING SPA TRUNK PIPING N w Pipe Size 8 fps (in.) GPM Loss (ft/ft) 2.0 82 0.10 2.5 117 0.09 3.0 181 0.07 2' 6" 1' 6" HYDRA /COOL LED o rn Q rn -1811 SWIM OUT Z W/ OUT WVnoncTAT1r WELL POINT THREADED PVC PIPE NOTE: SEE ATTACHED HYDRAULIC CALCULATIONS FOR ADDITIONAL DETAILS REGARDING PUMP FLOW RATES AND TOTAL DYNAMIC HEAD CALCULATIONS. cn GRATE TO BE ATTACHED 3/4" ROCK BED (MIN 3YDS Lf ROCK TO STABILIZE SOIL) REMOVE GRATE AND WELL POINT LINE FROM MAIN DRAIN, AND ATTACH AUX. PUMP LINE WHEN EMPTYING WELLPOINT SELECTED EQUIPMENT CALCULATIONS N.T.S. POOL 25' X 15' 356 SQFT 83LF 8,744 GALLONS 20' 6" 46' 2" N.T.S. POOL PUMP CURVE SPA PUMP CURVE n H I AS TX Ir- FLUSH -/ HYD A SPAR COOL LE H -18" SUNSHELF W/ BUBBLER AND UMBRELLA oM -811 SLEEVE 171211 A, ,, 8" X 8" FOOTER CONCRETE POUR `"- TOP AND COAT --------------------------------------------------------------------------------------- 46LF DECKO DRAIN - 691 SQFT - 121 6" 4306 SOUTH US 1 FORT PIERCE FL. (772) 465 2700 DRAWN BY: NANCY MCNALLY (772) 696-1747 17' 1" COVERED PORCH EXISTING PAVERS EXISTING PAVER EXTENSION REMOVED BY HOMEOWNER 4" THICK CONCRETE SLAB 6x6 - W1.4/W1.4 WWM OR FIBERMESH 1:3 MAX. SLOPE DECK WIDTH VARIES W/ EXISTING SOILS COMPACTED TO 95% MAX. COMPACTION 8" 6" WATERLINE TILE • 2- #3 BARS AT TOP - Z TIED TO VERT. STEEL z 8" • Z U Lij WIDTH VARIES FROM 4" - 6" 1= O a a -I J W #5 BAR W/ OVERLAP AT > = o END OF REBAR z_ U) 00 , ih i NOTES: 1.) IF NO SCREEN ENCLOSURE IS PROPOSED NO FOOTER IS PLASTER FINISH, REQUIRED, HOWEVER, SLOPE SHALL BE STARTED 2 FEET GEM COAT OR FROM EDGE OF PAVEMENT EQUIVALENT 2.) FOOTER SHOWN IS SUFFICIENT FOR STANDARD SINGLE • STORY SCREEN ENCLOSURE. ALTERNATE DESIGNS, R INCLUDING BUT NOT LIMITED TO NO FOOTER REQUIRED, PROVIDED BY ENGINEER FOR SCREEN ENCLOSURE SHALL TAKE PRECEDENCE OVER THIS DESIGN. • 3.) PAVERS MAY BE SUBSTITUTED FOR CONCRETE DECK. HOWEVER, FOOTER MUST STILL BE CONCRETE IN • • DIMENSIONS AND REINFORCEMENTS DEPICTED STEEL TEX. OR 4.) WALLS OVER 6' IN HEIGHT SHALL BE REINFORCED PER EQUIVALENT 6 WALL OPTIONS TABLE BELOW #3 BARS @ 12" O.C. E.W. CENTERED IN CONCRETE TYPICAL WALL AND DECK SECTION STAINLESS STEEL HANDRAIL (SAME BONDING FOR LADDER) POOL DECK CONNECT #8 BARE AWG COPPER WITH APPROVED BOND CLAMP 6" MAX. • • MIN. #8 BARE AWG COPPER AROUND PERIMETER OF POOL 18"-24" MIN. FOUR (4) CONNECTIONS (ONE CONNECT PERIMETER �\ EACH SIDE) W/ #8 BARE GROUND WIRE TO _ • AWG COPPER W/ GROUND SYSTEM APPROVED CLAMPS CONNECT #8 BARE AWG COPPER WITH APPROVED BOND CLAMP • LIGHT NICHE NOTE: BONDING PER 250.8 AND 680.26(B) OF NFPA 70, NATIONAL ELECTRICAL CODE. EQUIPOTENTIAL BONDING GRID DETAIL WASTE (RETAIN (MAX. 6' HEIGHT) ON SITE) PUMP WITH HAIR AND LINT N.T.S. VERT. REINFORCEMENT MAXIMUM WALL HEIGHTS #3 BARS @ 12" O.C. N/A N/A N/A 6' - 6" #3 BARS @ 9" O.C. N/A N/A 6'- 6" 7'- 0" #3 BARS @ 6" O.C. 6'-6" 7'-0" 7'-6" 8'-0" #3 BARS @ 3" O.C. 7'-6" 8'-0" 8'-6" 9'-0" REQ. WALL THICKNESS 4" THICK 5" THICK 6" THICK 8" THICK HORIZ. REINFORCEMENT 43 BARS @ 12" O.C. #3 BARS @ 12" O.C. #3 BARS @ 9" O.C. #3 BARS @ 6" O.C. ALTERNATE WALL OPTIONS (WALL HEIGHT GREATER THAN 6') N.T.S. POOL EQUIPMENT LIST LIGHT: (1) HYDRA COOL COLOR LED COLOR TRANSFORMER: (1) 300 W TRANSFORMER JUNCTION BOX: STANDARD JBOX 5 HOLE SKIMMER: 2" AUTOMATIC MAIN DRAIN: CHANEL HYDRO JETS: NONE RETURNS: (3) THREE VACUUM: (1) ONE CHLORINATOR: DANDY TRUE CLEAR SALT FILTER: DANDY CS 100 PUMP: DANDY 1HP PUMP HEATER:RHEEM 119K BTU TIMER: STANDARD DECK TYPE: CONCRETE DECK SQFT: 691 SQFT EXISTING:N/A FOOTER: 8" X 8" WATER FEATURE:BUBBLER ON SUNSHELF r., ALARM: DECK GUARD SCREEN ENCLOSURE SPA EQUIPMENT LIST HEIGHT: FLUSH LIGHT: (1) HYDRA COOL LED COLOR MAIN DRAIN: CHANEL HYDRO JETS: (4) FOUR RETURNS: (2) TWO PUMP: DANDY 1.5 HP 2 SPEED MANUAL PUMP SPILLWAY: 10LF TILE DOOR W/ STEP OUT �6' 3 ' 1 BORIOT TI RESIDE"( 2628 CONIFER FORT PIERCE, FL 631-944-1380 1/4" = 1 ft STRAINER (SEE ATTACHED CALCULATIONS) FILTER SYSTEM W/PRESSURE GAGE AND AIR RELEASE VALVE LEGEND N CHECK VALVE N GATE VALVE -i FLOW DIRECTION N.T.S. MAIN RETURN LINE KA W X X K xZ Q Imo- ¢W ¢� C0 o' O o LU w Op �o HEATER 7 =X 00 oU) o �a O N - �� w - GENERAL NOTES 1. ALL FLOORS AND WALLS OF POOL TO BE CONSTRUCTED USING PNEUMATICALLY APPLIED CONCRETE WITH 28 DAY STRENGTH OF 2500 PSI. 2. REINFORCING STEEL SHALL CONFORM TO A.S.T.M. 615 GRADE 60 3. PIPING TO BE SCHEDULE 40 PVC BEARING NSF APPROVAL. 4. POOLS TO BE CONSTRUCTED ONLY ON CLEAN SAND OR ROCK. SOILS IN FINAL BACKFILL SHALL BE COMPACTED TO PROVIDE A MINIMUM BEARING CAPACITY OF 1000 PSF. ALL UNSUITABLE MATERIALS SHALL BE REMOVED AND REPLACED WITH CLEAN SAND PLACED AND COMPACTED IN 12" LIFTS. 5. ALL BACKFILL SHALL BE PLACED WITH CARE IN ORDER TO ENSURE THAT PLUMBING IS NOT DISTURBED. ALL FILL SHALL BE CLEAN SAND PLACED IN 12" LIFTS AND COMPACTED TO 98% OF MAXIMUM DENSITY. 6. THE CONTRACTOR SHALL TAKE ANY NECESSARY PRECAUTIONS IN ORDER TO PROTECT EXISTING STRUCTURES AFFECTED BY THE CONSTRUCTION. THE DESIGN ENGINEER ACCEPTS NO RESPONSIBILITY FOR THE SAFETY OF EXISTING STRUCTURES. 7. ENGINEERING PLOT PLANS WERE NOT PREPARED FROM LEGAL SURVEYS OF THE EXISTING LOT AND RESIDENCE. POOL CONTRACTOR AND/OR OWNER SHALL VERIFY ALL DIMENSIONS IN THE FIELD AND ESTABLISH LOT LINES WHEN NECESSARY, POOL CONTRACTOR AND/OR OWNER SHALL VERIFY LAYOUT SHOWN AND ALL DIMENSIONS PRIOR TO CONSTRUCTION. AS SUCH, THE ENGINEER ASSUMES NO RESPONSIBILITY FOR POOL CONSTRUCTION IN EASEMENTS OR REQUIRED SETBACKS. 8. CONTRACTOR SHALL LOCATE ALL EXISTING UTILITIES ON SITE AND SHALL MAINTAIN MINIMUM SEPARATIONS AS REQUIRED BY LOCAL REGULATIONS. GENERALLY, ELECTRICAL LINES SHALL BE A MINIMUM OF 10 FEET FROM OPEN WATER. 9. ALL UNSCREENED POOLS SHALL HAVE A FENCE A MINIMUM OF 4 FEET IN HEIGHT WITH SELF-LOCKING GATES. 10. WHERE POOLS ABUT OR ARE PLACED NEAR SEAWALLS OR BULKHEADS SPECIAL CARE SHOULD BE TAKEN. NOTIFY ENGINEER OF THIS CONDITION FOR ANALYSIS AND RE -DESIGN IF NECESSARY. 11. PATIO DESIGN MAY BE NOTED TO BE COMPLETED BY OTHERS. WHEN NOTED, ANY DETAILS REFERRING TO PATIO DESIGN ARE NOT APPLICABLE. THE TYPICAL WALL SECTIONS OF POOL ARE NOT APPLICABLE TO PAVEMENT DESIGN. 12. VACUUM LINE SHALL INCLUDE A SPRING LOADED SELF CLOSING COVER. 13. THE SWIMMING POOL HAS BEEN DESIGNED TO BE COMPLIANT WITH THE 2020 FLORIDA BUILDING CODE 7TH EDITION, AS WELL AS THE 2017 NATIONAL ELECTRIC CODE, ANSI/APSP-7, AND SHALL BE ANSI 15 COMPLIANT, 14. BASE MATERIAL THICKNESS MUST BE 125% OF CONCRETE FASTENER EMBEDMENT. 15. HOMEOWNER MUST BE AWARE OF THE POSSIBILITY OF EROSION AND SHALL BE RESPONSIBLE FOR MAINTENANCE IN ORDER TO PREVENT FAILURE. 16. WATER VELOCITY MAXIMUM 8 FT/SEC AS PER FBC 2020-R4501.6.3 17. POOL BARRIER TO COMPLY WITH FBC 2020-R4501.17 18. SKIMMERS TO COMPLY WITH FBC 2020-4501.21.2 19. EQUIPMENT FOUNDATION CONCRETE SLAB, MIN. 3.5" THICK, POUR IN PLACE. 20. WATER HEATING EQUIPMENT TO COMPLY WITH FBC 2020-R4501.14 21. ALL DECK AND SLAB CONCRETE SHALL HAVE A COMPRESSIVE STRENGTH OF 3000 P.S.I. IN 28 DAYS UNLESS OTHERWISE NOTED. 22. ELECTRICAL RECEPTACLES AND FIXTURES SHALL BE ARRANGED TO COMPLY WITH FRC E4203, OR NEC 680.22 23. ALL BONDING INCLUDING EQUIPMENT, WATER AND EQUIPOTENTIAL SHALL COMPLY WITH FRC E4204 OR NEC 680.26, AS APPLICABLE. 24, GLASS TILE MAY BE SELECTED FOR USE BY CONTRACTOR. WHERE INSTALLED IN HORIZONTAL APPLICATIONS, THE TILE SHALL BE NON-SKID. THIS MAY BE ACHIEVED BY APPLYING LIQUIGUARD TECHNOLOGIES SOLIDSTEPCOTE 04 NON -SLIP COATING OR APPROVED EQUAL. NEC POOL PUMP ENERGY EFFICIENCY REQUIREMENTS IS IT A RESIDENTIAL POOL? (NOT A SPA) (�c`' NO REQUIREMENTS APPLY TO EXISTING POOL DOESN'T APPLY TO REPLACEMENTS/ADDITIONS AND NEW COMMERCIAL POOLS CONSTRUCTION POOL/SPA IS THE PUMP MOTOR USED TO FILTER WATER? u W Z j a Z- a� W w ¢ ¢ o a N S N �E O o w z ¢ AIR 4 0 0 � D_ BLOWER LU Q N a m PUMP WITH HAIR AND LINT CANNOT BE SPLIT -PHASE, SHADED DOESN'T APPLY TO N STRAINER (SEE ATTACHED POLE OR CAPACITOR CIRCULATION WITHOUT CALCULATIONS) START -INDUCTION TYPES FII IT NOTE: PIPE SIZING TO BE DETERMINED BY HYDRAULIC CALCULATIONS PLUMBING DIAGRAM N.T.S. WP MANUAL STARTER SWITCH (TYP.) 3 - #12 WIRES IN 3/4" CONDUIT TO PUMP -► TO PUMP 2 (IF APPLICABLE) TO ELEC. SERVICE VIA WATER PROOF PANEL -► TO BLOWER (IF APPLICABLE) G.F.I. NO MORE THAN 20' FROM POOL TO HEATER (IF APPLICABLE) EDGE AND NOT WITHIN 10' OF POOL EDGE 3 #8 WIRES IN 1" CONDUIT JUNCTION BOX 3 -#12 WIRES IN 3/4" CONDUIT 48" MIN. SPST TOGGLE SWITCH WATER LINE 12V TRANS. 18" MIN 8" 1" NON -CORROSIVE CONDUIT 12V LIGHT W/ POOL WALL AND DECK LOW WATER (SEE TYPICAL SECTION) CUTOFF DEVICE ELECTRICAL DIAGRAM 18" 1 12" MIN. I 12" MIN, N.T.S. N.T.S. SWIMOUT DEPTH DETAIL N.T.S. 6'- 9' 3'- 6' 3' ANGLE OF REPOSE = 1.5:1 8" THICK WALL W/ #3 BARS @ 6" O.C. E. W. 6" THICK WALL W/#3 REBAR @ 12" O.C.E.W. 5" THICK WALL W/#3 REBAR @ 12" O.C.E.W., NOTE: SEE TYPICAL WALL SECTION WHEN WALL FALLS OUTSIDE OF THE ANGLE OF REPOSE ANGLE OF REPOSE IS THE TOTAL HORESPOWER ONE OR LARGER? TOTAL HP = PUMP HP x SERVICE FACTOR ALSO FOLLOW THESE REQUIREMENTS: SINGLE SIPPED PUMP PUMP AND PUMP MOTORS MUST BE TWO OR MORE SPEEDS. PERMITTED. ADDITIONAL CONTROLS NED TO BE CAPABLE OF OPERATING AT A REQUIREMENTS MAY APPLY MINIMUM OF TWO SPEEDS. CONTINUE ON. DEFAULT CIRCULATION MUST BE THE RESIDENTIAL FILTRATION SPEED. THE HIGHER SPEED OVERRIDE IS NOT TO EXCEED ONE NORMAL CYCLE OR 24 HOURS, WHICHEVER IS LESS. SOLAR POOL HEATING SYSTEMS ARE PERMITTED TO RUN AT HIGHER SPEEDS DURING PERIODS OF USABLE HEAT GAIN. IS THIS NEW CONSTRUCTION? NO ADDITIONAL REQUIREMENTS PER APSP-15:. NO ADDITIONAL SIZE THE PUMP BASED ON. REQUIREMENTS ARE IN POOL GALLONS / 360 MIN. AND SELECTING PUMP FROM PLACE DATABASE WITH CURVE A OR C LISTED FLOWRATE EQUAL TO OR LESS THAN CIRCULATED FILTRATION FLOWRATE. - A TIME SWITCH MUST BE INSTALLED TO ALLOW POOL OWNERS TO RUN THE POOL FILTRATION PUMP ONLY DURING THE OFF-PEAK PERIOD AND FOR THE MINIMUM TIME NECESSARY TO MAINTAIN THE WATER IN THE CONDITION REQUIRED BY APPLICABLE PUBLIC HEALTH STANDARDS. FILTERS MUST HAVE A MINIMUM AREA BASED ON THE 6 HOUR TURNOVER FLOW RATE. POOL GAL. / 360 MIN. = FLOWRATE (IN GPM) DIVIDE GPM BY A NUMBER SHOWN TO FIND THE FILTER'S MIN. SQUARE FOOTAGE. (CARTRIDGE = .375, SAND = 15, DE = 2) MIN. DIAMETER OF BACKWASH VALVES MUST BE TWO INCHES OR THE DIAMETER OF THE RETURN PIPE WHICHEVER IS GREATER, SWEEP ELBOWS ARE RECOMMENDED. (REMEMBER: RESIZE PIPING SO VELOCITY AT MAX FLOW DOES NOT EXCEED 8 FPS IN THE SUCTION LINE AND 6 FPS IN THE SUCTION LINE, AND ALSO MEETS VGB/ANSI-7 ENTRAPMENT AVOIDANCE REQUIREMENTS.) PLUG PORTS NOT BEING USED OPTIONAL SINGLE INTERIOR POOL FINISH CONNECTION OR FRAME / MUD -RING HYDROSTATIC VALVE D4__. •7s 2°, ^' •• a_ .® �f •.`®, a.�o' r..p®' a _ .°a_- .°;Y..°B a :,),; w,as, �se °o °® •'o- a, v`,®.- v.`\� r l v t _'®� r «.o4t"°-,. o-. 9, vo-_i ��8, v �B, ®�', v °,P ®r _ ®, _ r %®•_ �-n• r %r• „•r a. a• R•.' a ' moo. � ', � °a � +a ... ®. A w Op. , \. w • \. ° \. ` \. a \. 1 ,a ° ® w . w w ®. a ,. 4 ,- w ,. .k ®. * ,. ° ®_ °,'\. .. .. .. .. .. GRAVEL EARTH SINGLE PIPE CONNECTION ON ANY SHOTCRETE/GUNNITE TO PUMP OF THREE PORTS. 1-1/2". 2 2-1/2". " OR GREATER PIPE CUSTOM MOLDED PRODUCTS 32" CHANNEL DRAIN NOTE: 2.5" CONNECTIONS ON THIS VGB-2009 COMPLIANT - MODEL: CMP 25506-32X INSTALLATION NOTE: THE MAXIMUM FLOW RATING FOR THIS SUCTION FITTING AS CONFIGURED WITH OUTER PORTS PLUGGED AND CENTER PORT OPEN IS 200 GPM (FLOOR) WHEN USING 2.5" PLUMBING AND 184 GPM WHEN USING 2" PLUMBING. CHANNEL DRAIN INSTALLATION DETAIL N.T.S. SAFETY NOTES 1. NO DIVING BOARD OR DIVING IS ALLOWED IN ANY POOL WITH A DEPTH LESS THAN 8'-81, AND SPECIFICALLY DESIGNED FOR DIVING. THIS POOL DOES NOT CONFORM TO THESE REQUIREMENTS AND NO DIVING SHALL BE PERMITTED 2. THIS POOL TO BE EQUIPPED WITH CHILD SAFETY FENCE AROUND THE PERIMETER OF THE POOL OR ALARMS AT THE ENTRANCES TO THE POOL (ONE TO BE CHECKED). gy�1 d I NOTE: LAYOUT PROVIDED BY CONTRACTOR POOL LAYOUT SCALE: 1/4" = V N.T.S. POOL TDH CALCULATION Total Dynamk Head 8 fps return velocity reaulred by APSP 15 Step # 6 !C .. l� rr.lrw 1. a.: $.E k o Step # 9 ® B tekYllMr '�3�ntt�s rt'6�rii� ;. NLBV Slide Valve Step # 13 zaect r''�r ........ in I ► u 3h En . Yal t . ,rQataPs1 = <: $ c$ Step # 7 1�... ... y �p .IYA.� ri Taffii{W towLri0ltYltiMl� .. Y.t ��. ern 1. itf lilt @ $ ;in #1C Sept Jds3d"' ie€aater i e antt ix� AE2000 an re Pro Series by ZODIAC"' Step # 6 .,. � •?�+ !�`. _....;: �.. ' is Step # 9 - t $ E 4 B $ Ste p#13 ail ,' .• fi kC r'nM k Title 24 Standards ----- ep --- # 7 ------ St B", S 1Z ' •� �. ; `: %1k1f�1':�r8 �iigTk )��� Sri; �rriil7°Y CunnRNi •iNiLtiilit � iri Phi [ rzir iAlr are. 0 Pro Series ^� byZODIACO N W 461211 - H - 8" X 8" FOOTER ] - �-- NTH . . U H ^U 7' Tx \ FLUSH —/ HYD SPA R COOL H POOL 25' X 15' LE 356 SQFT 83LF - $" 2' 6" q1 611 HYDRA 8,744 GALLONS SUNSHELF W/ /COOL LED a BUBBLER AND UMBRELLA SLEEVE -�8 M 171211 13" 1' 3" SWIM OUT (FRFLnW _ 201611 )R W/ R P OUT CONCRETE POUR Ln TOP AND COAT -------------------------------------------- ---------------------------------------------------------- - - -- ------------------------------------------------- 46LF DECKO DRAIN 691 SQFT - 4306 SOUTH U5 1 FORT PIERCE FL. (772) 465 2700 DRAWN BY: NANCY MCNALLY (772) 696-1747 The Association of iijQ n►_1 ,'' P' Pool & Spa Professionals` 17' 1" COVERED PORCH EXISTING PAVERS EXISTING PAVER EXTENSION REMOVED BY HOMEOWNER ANSVAPSPACC 15 ENERGY EFFICIENCY COMPLIANCE INFORMATION FOR RESIDENTIAL SWIMMING POOLS PROJECT NAME: AND ADDRESS BORIOTTI CONTRACTOR NAME AND ADDRESS: LOUDEN POOLS 2628 CONIFER 4306 S US HWY 1 FORT PIERCE, FL FT. PIERCE FL OWNER: BORIOTTI CONTRACTOR PHONE: (772) 465-2700 DATE: 6/12/2021 i nis inrormaton sneet was prepared oy the At'SP-15 Kesidentiai Swimming Pooi ano Spa tnergy ttnciency standard Writing Committee of the Association of Pool and Spa Professionals (APSP). It is not part of the American National Standard ANSI/APSP/ICC-15 2011 but is included for information only. Contractors should acquire and comply with the ANSI/APSP/ICC-15 2011 standard which can be purchased at www.apsp.org. 1. §5.2.1: Calculated pool volume a. Gallons: 8,788 ; or b. Calculated Gallons: 356 (surface area) X 3.3 (average depth) X 7.48 (gal/ft^3) = 8,788 2. §5.2.1: Calculated maximum filtration flow rate (Pool volume r 360 or 36gpm whichever is larger) 3. §5.2.2: Auxiliary Pool Load: ayes, No? (Enter the highest 'auxiliary pool load" to be powered by the swimming pool filtration pump. Do not add auxiliary pool load flow rates together, only the highest is used.) 4. Calculated maximum flow rate (Item 2 or item 3, whichever is larger.) S. §5.5.1: Pipe sizing: a. Minimum suction pipe diameter (Enter the smallest pipe size from Table 1 with a 6 fps flow capacity the some or more than item 4.) b. Minimum suction branch pipe diameter (Calculate: Item 4. 36 (gpm) Branch Pipes 1 (quantity) = branch flow rate 36 (gpm). Enter the smallest pipe size from Table 1 with a 6 fps flow capacity the some or more than the calculated suction branch flow rate.) c. Minimum return pipe diameter (Enter the smallest pipe size from Table 1 with a 8 fps flow capacity the same or more than item 4.) d. Minimum return branch pipe diameter (Calculate: Item 4. 36 (gpm) _ Branch Pipes 1 (quantity) = branch flow rate 36 (gpm). Enter the smallest pipe size from Table 1 with a 8 fps flow capacity the some or more than the calculated return branch flow rate.) 6. §5.4.1: Filter type and size: a. Filter type: (Cartridge, DE, Sand) b. Minimum filter area (Calculate: item 4. 36 (gpm) _ filter factor 0.375 ) Filterfactors: Cartrid e=0.375, Sand=15, Diatomaceous Earth=2 7. §5.4.2: Backwash valve: 13 Yes, No? (When using a backwash valve, enter result of item 5c or 2 inches whichever is larger) Table 1 45'" Nominal GPM a 6 fps 38 63 1 90 138 1851 238 5" 374 540 Nominal PM e 8 fps 51 84 119 184 247 317 499 720 8. Pump selection: §5.3.2.1: Pools 17,000 gallons or less, select pump* from the database with a Curve -A gpm flow equal to item 2 or less. §5.3.2.2: Pools 17,001 gallons or more, select pump* from the database with a Curve-C gpm flow equal to item 2 or less. *Multi - speed pumps must have one speed listed that satisfies this requirement. a. Pump model b. Pump flow (§5.3.2.1, 5.3.2.2: Applicable Curve A or C gpm flow listeg in database) 4/4/12 ANSI/APSP/ICC- 1§ Standard Writing Committee Form I8a. VSFHP1.0 1of2 POOL LAYOUT SCALE: 3/16" = 1' POOL EQUIPMENT LIST LIGHT: (1) HYDRA COOL COLOR LED COLOR TRANSFORMER: (1) 300 W TRANSFORMER JUNCTION BOX: STANDARD JBOX 5 HOLE SKIMMER: 2" AUTOMATIC MAIN DRAIN: CHANEL HYDRO JETS: NONE RETURNS: (3) THREE VACUUM: (1) ONE CHLORINATOR: DANDY TRUE CLEAR SALT FILTER: DANDY CS 100 PUMP: JANDY 1HP PUMP HEATER:RHEEM 119K BTU TIMER: STANDARD DECK TYPE: CONCRETE DECK SQFT: 691 SQFT EXISTING: N/A FOOTER: 8" X 8" WATER FEATURE:BUBBLER ON SUNSHELF N ALARM: DECK GUARD SCREEN ENCLOSURE SPA EQUIPMENT LIST HEIGHT: FLUSH LIGHT: (1) HYDRA COOL LED COLOR MAIN DRAIN: CHANEL HYDRO JETS: (4) FOUR RETURNS: (2) TWO PUMP: DANDY 1.5 HP 2 SPEED MANUAL PUMP SPILLWAY: 10LF TILE DOOR W/ STEP OUT �6' 3 ' I e e BORIOTTI RESIDEW 2628 CONIFER FORT PIERCE, FL 631-944-1380 fgg'1 I: 1/4" = 1 ft ANSI/APSP/ICC 15 ENERGY EFFICIENCY COMPLIANCE INFORMATION FOR RESIDENTIAL SWIMMING POOLS Component Section Requirements Check Heaters 4.4.1.1 Heater has no pilot light W1 4.4.1.2 Readily accessible on -off switch mounted outside of the heater 10 4.3.1.3 No electric resistance heating unless for inground spa with tight fitting cover with R-6 insulation, or for pool with 60% of documented pool heating from on -site solar or recovered energy. f 11 4.3.2 Heater efficiency: gas/oil fired heater efficiency at least 78%, heat pump COP at least 4.0 R Pool systems 5.1.1 Pool filter pump listed in database o 5.3.1 Pool filter pump with total horsepower 1.0 or more is multi -speed 5.3.3 Multi -speed pump controller programmed to default to the filtration flow rate when no auxiliary pool loads are operating within 24 hours and programmed with temporary override capability for servicing. 5.3.4 Single -speed pump controller capable of operating pump during off-peak electric demand. 5.5.2 Pipe before pump has at least 4 diameters of straight pipe. o 5.5.3 System installed with solar, or setup for the future addition of solar heating equipment by installing 18 inches of horizontal or vertical pipe after the filter and before a heater, or built-in or built-up connections, or dedicated pipe to and from the pool. 5.5.6 Directional inlets for mixing pool water. 211 4/4/12 ANSI/APSP/ICC- 15 Standard Writing Committee Form 2of2