Enphase Storage System
Enphase The Enphase Encharge 10 "" all -in -one AC -coupled
storage system is reliable, smart, simple, and safe. It is
Encharge 14 comprised of three base Encharge 3'" storage units, has
a total usable energy capacity of 10.08 kWh and twelve
embedded grid -forming microinverters with 3.84 kW
power rating. It provides backup capability and installers
can quickly design the right system size to meet the
needs of both new and retrofit solar customers.
C
1=W AMID ENPHASE
MR. IN
• Proven high reliability IQ Series Microinverters
• Ten-year limited warranty
Three independent Encharge storage base units
Twelve embedded IQ SX-BAT Microinverters
• Passive cooling (no moving parts/fans)
Smart
• Grid -forming capability for backup operation
• Remote software and firmware upgrade
• Mobile app-based monitoring and control
• Support for self consumption
• Utility time of use (TOU) optimization
Simple
Fully integrated AC battery system
• Quick and easy plug -and -play installation
• Interconnects with standard household AC wiring
Safe
Cells safety tested
• Lithium iron phosphate (LFP) chemistry for maximum
safety and longevity
To learn more about Enphase offerings, visit ffl9hafie,com i.
3 ENPHASE,
Enphase Encharge 10
MODEL NUMBER
ENCHARGE-10-1 P,NA Encharge 10 battery storage system with integrated Enphase Microinverters and battery
management unit (BMU). Includes:
Three Encharge 3.36 kWh base units (B03-A01-US00-1-3)
- One Encharge 10 cover kit with cover, wall mounting bracket, watertight conduit hubs, and
interconnect kit for wiring between batteries (B10-C-1050-0)
ACCESSORIES
ENCHARGE-HNDL-R1 One set of Encharge base unit installation handles
OUTPUT (AC) @ 240 VAC'
Rated (continuous) output power 3.84 kVA
Peak output power 5.7 kVA (10 seconds)
Nominal voltage / range 240 / 211 — 264 VAC
Nominal frequency range 60 157 — 61 Hz
Rated output current 16 A
Peak output current 24.6A (10 seconds)
Power factor (adjustable) 0,85 leading.., 0.85 lagging
Maximum units per 20 A branch circuit 1 unit (single phase)
Interconnection Single-phase
Max imurn AC short circuit fault current over 3 cycles 69.6 Arms
Round trip efficiency2 89%
BATTERY
Total capacity
10.5 kWh -"
Usable capacity
10,08 kWh
Round trip efficiency
96%
Nominal DC voltage
67.2 V
Maximum DC voltage
73.5 V
Ambient operating temperature range -15- C to 55° C (5° F to 1310 F) non -condensing
Optimum operating temperature range 0° C to 30° C (320 F to 860 F)
Chemistry Lithium iron phosphate (LFP)
MECHANICAL DATA
Dimensions (WxHxD) 1070 mm x 664 mm x 319 mm (42.13 in x 26.14 in x 12.56 in)
Weight Three individual44.2 kg (97.4 Ibs) base units plus 21.1 kg (48.7 Ibs) cover and mounting
bracket; total 154.7 kg (341 Ibs)
Enclosure Outdoor — NEMA type 3R
IQ 8X-BAT microinverter enclosure NEMA type 6
Cooling Natural convection — No fans
Altitude Up to 2500 meters (8200 feet)
Mounting Wall mount
FEATURES AND COMPLIANCE
Compatibility Compatible with grid -tied PV systems. Compatible with Enphase M215/M250 and IQ Series
Micros, Enphase Enpower, and Enphase IQ Envoy for backup operation.
Communication Wireless 2A GHz
Services Backup, self -consumption, TOU, Demand Charge, NEM Integrity
Monitoring Enlighten Manager and MyEnlighten monitoring options; API integration
Compliance UL 9540, UN 38.3, UL 9540A, UL 1998, UL 991, NEMA Type 3R, AC156
EMI: 47 CFR, Part 15, Class B, ICES 003
Cell Module: UL 1973, UN 38.3
Inverters: UL 62109-1, IEC 62109-2. UL 1741SA, CAN/CSA C22.2 No. 107.1-16, and IEEE 1547
LIMITED WARRANTY
Limited Warrantya >70%capacity, up to 10 years or4000 cycles
1. Supported in backup/off grid operations
2. AC to Battery to AC at 50% power rating.
3. Whichever occurs first. Restrictions apply.
To learn more about Enphase offerings, visit enphase.com
T) 2021 Enphase Energy. All rights reserved, Enphase, the Enphase logo, Encharge 10, and other trademarks or service names are the trademarks N P H A S
of Enphase Energy, Inc Data subject to change 2021.03-01 = ..
Data Sheet
Enphase Ensemble energy manaaernent system
Enphase
Enpower
9 ENPHASE
The Enp ,ase `7npower"' smart switch connects the
home to grid power, the Encharge storage system,
and solar PV It provides microgrid interconnection
device (MID) functionality by automatically detecting
and seamlessly transitioning the home energy system
from grid power to backup power in the event of a grid
failure. It consolidates interconnection equipment into
a single enclosure and streamlines grid independent
capabilities of PV and storage installations by
providing a consistent, pre -wired solution for
residential applications.
Reliable
Durable NEMA type 3R enclosure
Ten-year limited warranty
Smart
• Controls safe connectivity to the grid
Automatically detects grid outages
Provides seamless transition to backup
Simple
Connects to the load or service equipment' side of
the main load panel
Centered mounting brackets support single stud
mounting
• Supports conduit entry from the bottom, bottom left
side, and bottom right side
• Supports whole home and partial home backup and
subpanelbackup
Up to 200A main breaker support
Includes neutral -forming transformer for split phase
120/240V backup operation
To learn more about Enphase offerings, visit ennhase.com
E N P H S.
Enphase Enpower
MODEL NUMBER
EP200G101-M24OUS00 Enphase Enpower smart switch with neutral -forming transformer (NFT), Mlerogrid Interconnect Device ill
breakers, and screws. Streamlines grid -independent capabilities of PV and storage lnstailabans.
ACCESSORIES and REPLACEMENT PARTS
EP20OG-LITKIT Literature Kit far Enpower, Including labels, feed -through headers, screws and filler plates
EP20OG-NA-HD-200A Eaton type BR circuit breaker hold-down screw kit, 8RHDK125
EP20OG-HNDL-Rl
Enpower Installation handle kit (order separately)
Circuit breakers (as needed)' z
Not included, must order separately:
BRK-100A-2P-240V
Main breaker, 2 pole, 10DA, 25kAIC, CSR2100
BRK•125A-2P-240V
• Main breaker, 2 pole,125A, 25kAIC, CSR2125N
BRK-150A-213-240V
Main breaker, 2 pole,150A, 25kAIC, CSR2150N
URK-175A-2P-240V
• Main breaker, 2 pole,175A, 25kAIC, CSR2175N
BRK-200A-2P-240V
Main breaker, 2 pole, 200A, 25kAIC, CSR22DON
HRK-20A-2P-240V-0
• Circuit breaker, 2 pale, 20A,1 GkAIC, BR2208
BRK-30A-2P-240V
• Circuit breaker, 2 pole, 30A, 10kAIC, BR230B
BRK-40A-2P-240V
Circuit breaker, 2 pole, 40A,10kAIC, BR240B
BRK-60A-2P•240V
Clrcult breaker, 2 pole, 6DA,1 OkAIC, OR260
BRK•SOA-2P-240V
Circuit breaker, 2 pole, BOA,10kAIC, BR280
ELECTRICAL SPECIFICATIONS
Assembly rating Continuous operation at 100% of Its rating
Nominal voltage ! range (L-L)
Voltage measurement accuracy
Auxiliary contact for load control and excess PV control
Nominal frequency/range
Frequency measurement accuracy
Maximum continuous current rating
Maximum input overcurrent protection device
Maximum output overcurrent protection device
Mox imum overcurrent protection device rating for storage branch circuit'
Maximum overcurrent protection device rating for PV combiner branch circuit'
Neutral Forming Transformer (NFT)
240 VAC 1 100 - 310 VAC
±1%V nominal (i•1.2V L-N and it2.4V L-L)
24V,1A
60 Hz 156 -63 Hz
t0.1 Hz
160A
20 OA
200A
BOA
BOA
• Breaker rating (pre-installed):40A between L1 and Neutral,40A between L2and Neutral
• Continuous rated power: 360OVA
Maximum continuous unbalance current: 34A @ 120V
Peak rated power: 88GOVA for 30 seconds
Peak unbalanced current: 80A @ 120V for 30 seconds
MECHANICAL DATA
Dimensions (WxHxD) 50cm x 91.6cm x 24.6em (19.7 in x 36 in x 9.7 in)
Weight 38.5 kg (85lbs)
Ambient temperature range -40° C to +5D° C (-40° F to 1221 F)
Cooling Naturat convection, plus heat shield
Enclosure environmental rating
outdoor, NEMA type 3R, polycarbonate construction
Altitude
To 2500 meters (6200 feet)
WIRE SIZES
Connections
Main lugs and backup load lugs
9 P 9
Cu1AI:1 AWG — 300 KCMIL
(All lugs are rated to 90C)
CSR breakers
Cu/Al: 2 AWG — 300 KCM IL
BR breakers (wire provided)
6 AWG
AC combiner lugs, Encharge lugs, and generator lugs
14 AWG — 2 AWG
Neutral (large lugs)
CulAI: 6 AWG - 300 KCM I L
Neutral and ground bars
Large holes (5116.24 UNF)
14 AWG — 110 AWG
Small holes (10-32 UNF)
14 AWG — 6 AWG
COMPLIANCE
Compliance �~
UL 1741, UL 1741 $A, UL 1741 PCS, UL1g98, U1.869A•, UL67-, UL5081, VLSOE•
GSA 22.2 No, 107.1, 47 CFR, Part 15, Class B, ICES 003, AC156.
Enpower is approved for Use as Service Equipment in the United States'.
1 Compatible with BRHDK125 Hold -Down Kit to comply with 2017 NEC 710.15E
for back -fed circuit breakers.
2- The Enpower is rated 22 kAIC
3. Not included. Installer must provide properly rated breaker per circuit breaker
list above.
4. Sections from these standards were used during the safety evaluation and included in the UL 1741 listingg
5. Enpower is not suitable for use as service equipment in Canada.
To learn more about Enphase offerings, visit enWhase.com "'_ EN
p
D 2021 Enphase Energy. Ali rights reserved Enphase, the Enphase logo, Enpower, and other trademarks or service narlles are the trademarks of Enphase t I r" ,