Loading...
HomeMy WebLinkAboutENPHASE STORAGE SYSTEMData Sheet Enphase Storage System Enphase The Enphase Encharge 10 "" all -in -one AC -coupled storage system is reliable, smart, simple, and safe. It is Encharge 14 comprised of three base Encharge 3'" storage units, has a total usable energy capacity of 10.08 kWh and twelve embedded grid -forming microinverters with 3.84 kW power rating. It provides backup capability and installers can quickly design the right system size to meet the needs of both new and retrofit solar customers. C 1=W AMID ENPHASE MR. IN • Proven high reliability IQ Series Microinverters • Ten-year limited warranty Three independent Encharge storage base units Twelve embedded IQ SX-BAT Microinverters • Passive cooling (no moving parts/fans) Smart • Grid -forming capability for backup operation • Remote software and firmware upgrade • Mobile app-based monitoring and control • Support for self consumption • Utility time of use (TOU) optimization Simple Fully integrated AC battery system • Quick and easy plug -and -play installation • Interconnects with standard household AC wiring Safe Cells safety tested • Lithium iron phosphate (LFP) chemistry for maximum safety and longevity To learn more about Enphase offerings, visit ffl9hafie,com i. 3 ENPHASE, Enphase Encharge 10 MODEL NUMBER ENCHARGE-10-1 P,NA Encharge 10 battery storage system with integrated Enphase Microinverters and battery management unit (BMU). Includes: Three Encharge 3.36 kWh base units (B03-A01-US00-1-3) - One Encharge 10 cover kit with cover, wall mounting bracket, watertight conduit hubs, and interconnect kit for wiring between batteries (B10-C-1050-0) ACCESSORIES ENCHARGE-HNDL-R1 One set of Encharge base unit installation handles OUTPUT (AC) @ 240 VAC' Rated (continuous) output power 3.84 kVA Peak output power 5.7 kVA (10 seconds) Nominal voltage / range 240 / 211 — 264 VAC Nominal frequency range 60 157 — 61 Hz Rated output current 16 A Peak output current 24.6A (10 seconds) Power factor (adjustable) 0,85 leading.., 0.85 lagging Maximum units per 20 A branch circuit 1 unit (single phase) Interconnection Single-phase Max imurn AC short circuit fault current over 3 cycles 69.6 Arms Round trip efficiency2 89% BATTERY Total capacity 10.5 kWh -" Usable capacity 10,08 kWh Round trip efficiency 96% Nominal DC voltage 67.2 V Maximum DC voltage 73.5 V Ambient operating temperature range -15- C to 55° C (5° F to 1310 F) non -condensing Optimum operating temperature range 0° C to 30° C (320 F to 860 F) Chemistry Lithium iron phosphate (LFP) MECHANICAL DATA Dimensions (WxHxD) 1070 mm x 664 mm x 319 mm (42.13 in x 26.14 in x 12.56 in) Weight Three individual44.2 kg (97.4 Ibs) base units plus 21.1 kg (48.7 Ibs) cover and mounting bracket; total 154.7 kg (341 Ibs) Enclosure Outdoor — NEMA type 3R IQ 8X-BAT microinverter enclosure NEMA type 6 Cooling Natural convection — No fans Altitude Up to 2500 meters (8200 feet) Mounting Wall mount FEATURES AND COMPLIANCE Compatibility Compatible with grid -tied PV systems. Compatible with Enphase M215/M250 and IQ Series Micros, Enphase Enpower, and Enphase IQ Envoy for backup operation. Communication Wireless 2A GHz Services Backup, self -consumption, TOU, Demand Charge, NEM Integrity Monitoring Enlighten Manager and MyEnlighten monitoring options; API integration Compliance UL 9540, UN 38.3, UL 9540A, UL 1998, UL 991, NEMA Type 3R, AC156 EMI: 47 CFR, Part 15, Class B, ICES 003 Cell Module: UL 1973, UN 38.3 Inverters: UL 62109-1, IEC 62109-2. UL 1741SA, CAN/CSA C22.2 No. 107.1-16, and IEEE 1547 LIMITED WARRANTY Limited Warrantya >70%capacity, up to 10 years or4000 cycles 1. Supported in backup/off grid operations 2. AC to Battery to AC at 50% power rating. 3. Whichever occurs first. Restrictions apply. To learn more about Enphase offerings, visit enphase.com T) 2021 Enphase Energy. All rights reserved, Enphase, the Enphase logo, Encharge 10, and other trademarks or service names are the trademarks N P H A S of Enphase Energy, Inc Data subject to change 2021.03-01 = .. Data Sheet Enphase Ensemble energy manaaernent system Enphase Enpower 9 ENPHASE The Enp ,ase `7npower"' smart switch connects the home to grid power, the Encharge storage system, and solar PV It provides microgrid interconnection device (MID) functionality by automatically detecting and seamlessly transitioning the home energy system from grid power to backup power in the event of a grid failure. It consolidates interconnection equipment into a single enclosure and streamlines grid independent capabilities of PV and storage installations by providing a consistent, pre -wired solution for residential applications. Reliable Durable NEMA type 3R enclosure Ten-year limited warranty Smart • Controls safe connectivity to the grid Automatically detects grid outages Provides seamless transition to backup Simple Connects to the load or service equipment' side of the main load panel Centered mounting brackets support single stud mounting • Supports conduit entry from the bottom, bottom left side, and bottom right side • Supports whole home and partial home backup and subpanelbackup Up to 200A main breaker support Includes neutral -forming transformer for split phase 120/240V backup operation To learn more about Enphase offerings, visit ennhase.com E N P H S. Enphase Enpower MODEL NUMBER EP200G101-M24OUS00 Enphase Enpower smart switch with neutral -forming transformer (NFT), Mlerogrid Interconnect Device ill breakers, and screws. Streamlines grid -independent capabilities of PV and storage lnstailabans. ACCESSORIES and REPLACEMENT PARTS EP20OG-LITKIT Literature Kit far Enpower, Including labels, feed -through headers, screws and filler plates EP20OG-NA-HD-200A Eaton type BR circuit breaker hold-down screw kit, 8RHDK125 EP20OG-HNDL-Rl Enpower Installation handle kit (order separately) Circuit breakers (as needed)' z Not included, must order separately: BRK-100A-2P-240V Main breaker, 2 pole, 10DA, 25kAIC, CSR2100 BRK•125A-2P-240V • Main breaker, 2 pole,125A, 25kAIC, CSR2125N BRK-150A-213-240V Main breaker, 2 pole,150A, 25kAIC, CSR2150N URK-175A-2P-240V • Main breaker, 2 pole,175A, 25kAIC, CSR2175N BRK-200A-2P-240V Main breaker, 2 pole, 200A, 25kAIC, CSR22DON HRK-20A-2P-240V-0 • Circuit breaker, 2 pale, 20A,1 GkAIC, BR2208 BRK-30A-2P-240V • Circuit breaker, 2 pole, 30A, 10kAIC, BR230B BRK-40A-2P-240V Circuit breaker, 2 pole, 40A,10kAIC, BR240B BRK-60A-2P•240V Clrcult breaker, 2 pole, 6DA,1 OkAIC, OR260 BRK•SOA-2P-240V Circuit breaker, 2 pole, BOA,10kAIC, BR280 ELECTRICAL SPECIFICATIONS Assembly rating Continuous operation at 100% of Its rating Nominal voltage ! range (L-L) Voltage measurement accuracy Auxiliary contact for load control and excess PV control Nominal frequency/range Frequency measurement accuracy Maximum continuous current rating Maximum input overcurrent protection device Maximum output overcurrent protection device Mox imum overcurrent protection device rating for storage branch circuit' Maximum overcurrent protection device rating for PV combiner branch circuit' Neutral Forming Transformer (NFT) 240 VAC 1 100 - 310 VAC ±1%V nominal (i•1.2V L-N and it2.4V L-L) 24V,1A 60 Hz 156 -63 Hz t0.1 Hz 160A 20 OA 200A BOA BOA • Breaker rating (pre-installed):40A between L1 and Neutral,40A between L2and Neutral • Continuous rated power: 360OVA Maximum continuous unbalance current: 34A @ 120V Peak rated power: 88GOVA for 30 seconds Peak unbalanced current: 80A @ 120V for 30 seconds MECHANICAL DATA Dimensions (WxHxD) 50cm x 91.6cm x 24.6em (19.7 in x 36 in x 9.7 in) Weight 38.5 kg (85lbs) Ambient temperature range -40° C to +5D° C (-40° F to 1221 F) Cooling Naturat convection, plus heat shield Enclosure environmental rating outdoor, NEMA type 3R, polycarbonate construction Altitude To 2500 meters (6200 feet) WIRE SIZES Connections Main lugs and backup load lugs 9 P 9 Cu1AI:1 AWG — 300 KCMIL (All lugs are rated to 90C) CSR breakers Cu/Al: 2 AWG — 300 KCM IL BR breakers (wire provided) 6 AWG AC combiner lugs, Encharge lugs, and generator lugs 14 AWG — 2 AWG Neutral (large lugs) CulAI: 6 AWG - 300 KCM I L Neutral and ground bars Large holes (5116.24 UNF) 14 AWG — 110 AWG Small holes (10-32 UNF) 14 AWG — 6 AWG COMPLIANCE Compliance �~ UL 1741, UL 1741 $A, UL 1741 PCS, UL1g98, U1.869A•, UL67-, UL5081, VLSOE• GSA 22.2 No, 107.1, 47 CFR, Part 15, Class B, ICES 003, AC156. Enpower is approved for Use as Service Equipment in the United States'. 1 Compatible with BRHDK125 Hold -Down Kit to comply with 2017 NEC 710.15E for back -fed circuit breakers. 2- The Enpower is rated 22 kAIC 3. Not included. Installer must provide properly rated breaker per circuit breaker list above. 4. Sections from these standards were used during the safety evaluation and included in the UL 1741 listingg 5. Enpower is not suitable for use as service equipment in Canada. To learn more about Enphase offerings, visit enWhase.com "'_ EN p D 2021 Enphase Energy. Ali rights reserved Enphase, the Enphase logo, Enpower, and other trademarks or service narlles are the trademarks of Enphase t I r" , Energy, InL. Data subject to change 08-05-2021