Loading...
HomeMy WebLinkAboutEnergy; Checklist ReportFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Lot 119 Block 5 Waterstone 1820 BGL Builder Name: ADAMS HOMES Street: 5338 San Bendetto Place Permit Office: City, State, Zip: Fort Pierce, FL , 34951 Permit Number: Owner: Jurisdiction: 661000 Design Location: FL, ST LUCIE_CO_INTL County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (2120.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 1850.00 ft2 3. Number of units, if multiple family 1 b. Frame - Wood, Adjacent c. N/A R=13.0 270.00 ft2 R= ft2 4. Number of Bedrooms 4 d. N/A R= ft2 5. Is this a worst case? No 10. Ceiling Types (1820.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1820.00 ft2 6. Conditioned floor area above grade (ft2) 1820 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R_ 2R 11. Ducts ft2 7. Windows(239.3 sqft.) Description Area a. Sup: Attic, Ret: Main, AH: Main 6 364 a. U-Factor: Dbl, U=0.33 184.92 ft2 SHGC: SHGC=0.23 b. U-Factor: Dbl, U=0.33 20.42 ft2. 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.31 a. Central Unit 35.0 SEER:15.00 c. U-Factor: Dbl, U=0.55 17.78 ft2 SHGC: SHGC=0.70 13. Heating systems 'kBtu/hr Efficiency d. U-Factor: other (see details) 16.19 ft2 a. Electric Heat Pump 34.6 HSPF:8.50 SHGC: other (see details) Area Weighted Average Overhang Depth: 4:067 ft. Area Weighted Average SHGC: 0.270 14. Hot water systems 8. Floor Types (1820.0 sqft.) Insulation Area a. Electric Cap: 40 gallons a. Slab -On -Grade Edge Insulation R=0.0 1820.00 ft2' b. Conservation features EF: 0.940 b. N/A R= ft2 None c. N/A R= ft2 15. Credits Pstat Total Proposed Modified Loads: 65.12 Glass/Floor Area: 0.131 PAC c Total Baseline Loads: 68.84 1�1�7a7 i I hereby certify that the plans and specifications covered by Review of the plans and this calculation are in complianc i e Florida En ""'^�. specifications covered by this 0�- = p Code. calculation indicates compliance y ;,'' _ z,?,�� with the Florida Energy Code. rrnr �• "�% :;=.`" ; `�„ O PREPARED BY: Before construction is completed DATE: 03-10-21190 Winn Kepmany this building will be inspected for , compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida EgaLclyC C'pDt� OWNER/AGED4 BUILDING OFFICIAL: DATE: DATE: Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with. R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 3/10/2020 9:31 AM EnergyGauge® USA 6.0:02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Lot 119 Block 5 Waterstone 1 Bedrooms: 4 Address Type: Lot Information Building Type: User Conditioned Area: 1820 Lot # 119 Owner Name: Total Stories: 1 Block/Subdivision: Waterstone # of Units: 1 Worst Case: No PlatBook: Builder Name: ADAMS HOMES Rotate Angle: 0 Street: 5338 San Bendetto Pla Permit Office: Cross Ventilation: No County: St. Lucie Jurisdiction: 661000 Whole House Fan: No City, State, Zip: Fort Pierce , Family Type: Single-family FL, 34951 New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Blockl 1820 18200 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 1820 18200 Yes 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 33 ft 0 1820 ft2 ---- 0.42 0 0.58 ROOF / Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 2035 ft2 456 ft2 Medium N 0.85 N 0.85 No 0 26.6 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 1820 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) Main 30 Blown 1820 ft2 0.11 Wood 3/10/2020 9:31 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4 J 't-UKIVI K4Ub-1U11 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height _ Sheathing Framing Solar Below _/Altjpo 1 NE Exterior Concrete Block - Int Insul Main 4.1 59 0 10 0 590.0 ft2 0 0 0.6 0 2 NW Exterior Concrete Block - Int Insul Main 4.1 20 0 10 0 200.0 ft2 0 0 0.6 0 3 SW Exterior Concrete Block - Int Insul Main 4.1 66 0 10 0 660.0 ft2 0 0 0.6 0 4 SE Exterior Concrete Block - Int Insul Main 4.1 40 0 10 0 400.0 ft2 0 0.6 0 5 - Garage Frame - Wood Main 13 27 0 10 0 270.0 ft2 0 0.23 0.01 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 NW Insulated Main None .25 3 6 8 20 ft2 2 - Insulated Main None .25 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NE 1 Vinyl Low-E Double Yes 0.33 0.23 N 6.9 ft2 1 ft 4 in 0 ft 10 in None Exterior 5 2 NE 1 Vinyl Low-E Double Yes 0.33 0.23 N 48.6 ft2 1 ft 4 in 0 ft 10 in None Exterior 5 3 NW 2 Vinyl Low-E Double Yes 0.33 0.31 N 7.1 ft2 9 ft 0 in 0 ft 6 in None None 4 NW 2 Vinyl Low-E Double Yes 0.33 0.23 N 16.2 ft2 1 ft 0 in 3 ft 11 in None Exterior 5 5 NW 2 Vinyl Low-E Double Yes 0.33 0.21 N 16.2 ft2 1 ft 0 in 5 ft 4 in None Exterior 6 NW 2 Vinyl Low-E Double Yes 0.33 0.31 N 13.3 ft2 9 ft 0 in 2 ft 0 in None None 7 SW 3 Vinyl Low-E Double Yes 0.33 0.23 N 48.6 ft2 1 ft 4 in 0 ft 10 in None Exterior 5 8 SE 4 Vinyl Low-E Double Yes 0.55 0.7 N 17.8 ft2 11 ft 5 in 0 ft 6 in None Exterior 5 9 SE 4 Vinyl Low-E Double Yes 0.33 0.23 N 32.4 ft2 1 ft 4 in 0 ft 10 in None Exterior 5 10 SE 4 Vinyl Low-E Double Yes 0.33 0.23 N 32.4 ft2 11 ft 6 in 0 ft 6 in None Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 396 ft2 396 ft2 64 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000445 2123.3 116.57 219.22 .1685 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:8.5 34.6 kBtu/hr 1 sys#1 3/10/2020 9:31 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4 `FOf M R405-2017 INPl1T SIIMMARV rW1=rK1 ICT 01=113nI2T COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 15 35 kBtu/hr 1167 cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.94 40 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS / -- Supply---- -- Return ---- Air CFM 25 CFM25 HVAC # �/ # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 364 ft2 Main 91 ft2 Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: CoolingJan Feb HeatinH Jan H Feb Mar HX Mar A r Apr Jul May Jun Jul May Jun rl Au ri Aurl Se SeP Oct Oct Nov Nov HX Dec DecVentin Jan Feb Mar [X] Apr [ May Jun Jul Aug Se [X] Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibs/s .ft. 0 ft2 0 ft 0.3 Main 3/10/2020 9:31 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4