HomeMy WebLinkAboutProduct Approval roofing Underlayment 1
1
Publications'I. Contact us BaS Site Ma Links I Search
a e Stets&Facts PubB P
BCIS Home ': In User Repfstration i Mot Topits Submtt Surch rg
Log
!
bLeyOProduct Approval
USER:Public User
P-duct'ocrnval M ny>Pr t or"soli -lion Sear-h>�nolat,on Ljg>Application Detail
FL# FL34539 Pr
Application Type New
Code Version 2020
Application Status Approved ¢ 'RECEIVED
Comments
"F '� 15
Archived St.Lucie County
Permitting
Beacon Sales Acquisitions,Inc.c/o Owens Coming Roofing and Asphalt
Product Manufacturer LLC
Address/Phone/Email 1 Owens Coming Parkway
Toledo,OH 43657
j74 )�87 3562 greg.keeler@owenscoming.com File Copy
Authorized Signature Greg Keeler
greg.keeler@owenscoming.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect.or a Licensed Florida
Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Zachary R.Priest
the Evaluation Report
Florida License PE-74021
Quality Assurance Entity PRI Construction Materials Technologies,LLC
Quality Assurance Contract Expiration Date 12/31/2024
Validated By Steven M.Urich, PE
Validation Checklist-Hardcopy Received
Certificate of Independence cl _Ro Csei OCR20001 7020 FSC Fval TRI-SUTLT GranVlar l?df
Referenced Standard and Year(of Standard) Standard Year
ASTM D 1970 2015
ASTM D 226 2009
Equivalence of Product Standards
Certified By
ht;ps:ililorldaoc 7iry org,:.;: _a __ .iso� aari^i_;. ,...';�4
':)ge of
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 10/14/2020
Date Validated 10/15/2020
Date Pending FBC Approval 10/25/2020
Date Approved 12/16/2020
S611111111nalev i4 products
FL# Model,,Number or Name Description
34539.1 TRI-BUILT Granular Underlayment A self-adhered underlayment used as an alternative to ASTM
D 226,Type II roofing felt.
Limits of Use Installation Instructions
Approved for use in HVH2:No FL 43_RO II OCR20001 2020 FBC Eval TRI-BUILT
Approved for use outside HVHZ:Yes Granularn
Impact Resistant:N/A Verified By:Zachary R.Priest PE-74021
Design Pressure:N/A
Created by Independent Third Party:Yes
Other:See evaluation report for limits of use. Evaluation Reports
FL34539 RO AE QC:-R 001 2020 cBC E"al TR?-aulur
I IGranul r
Created by Independent Third Party:Yes
Contact Us::2601^iair stone Road Tallahassft FIL 32392 phone:850-487-1824
emd statement
The state of Florida Is an AA/EEO employer.Cony rioht 2007- 013 ate of Florida.::Privacy Statement::Accessibility Statement:: ——
Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic
mail to this entity.instead,contact the office by phone or by traditional mail.If you have arty questions,please contact R50.487-1395.'Pursuant to section
455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have
one.The emalls provided may be used for official communication with the licensee.However email addresses are public record-If you do not wish to supply a
personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter
455,F.S.,please dick h&M.
Product Appronl Acoopts:
Credit Card
Safe
hl!;I "ifIad�r-,L i ng crq(br;r_ .;p_dti ,5{'• ?oar:jr,, -wGFVX0vrt;a
pC):, riy^J1,ai;, . ,r +;r` sUeu%'UvC`:,;1R ,d3d 1 1 '3 ?M
n aayr ry
Certificate of Authorization No. 29824
CREEK .
17520 Edinburgh Drive
Tampa,FL 33647
TECHNICAL SERVICES, LLC (813)480-3421
EVALUATION REPORT FLORIDA BUILDING CODE,7'"EDITION(2020)
Manufacturer: BEACON SALES ACQUISITIONS,INC. Issued October 14,2020
c/o OWENS CORNING ROOFING AND ASPHALT
LLC
1 Owens Coming Parkway
Toledo,OH 43657
(800)438-7465
www.owenscorning.com
Manufacturing Location: Houston,TX
Brentwood, NH
Quality Assurance: PRI Construction Materials Technologies,LLC (QUA9110)
SCOPE
Category: Roofing
Subcategory: Underlayments
Code Sections: 1507.1.1, 1507.1.1.1
Properties: Physical properties
REFERENCES
Entily Report No. Standard Year
PRI Construction Materials Technologies(TST6049) OCF-294-02-01 ICC-ES AC 2012
ICC-ES AC 488' 2012
PRI Construction Materials Technologies(TST6049) OCF-338-02-01 ASTM D 1970 2015a
'Determined to be equivalent to ASTM D 226-09,Type II
PRODUCT DESCRIPTION
TRI-BUILT Granular A self-adhered underlayment used as an alternative to ASTM D 226,Type 11 roofing felt.
Underlayment The underlayment is composed of SBS modified asphalt with a fiberglass'mat internal
reinforcement and is surfaced with granules. The product is supplied with a nominal
thickness of 50 mils in 1.95-sq rolls with nominal dimensions of 3-ft x 65-ft. See
manufacturer's installation instructions for further detail.
OCR20001 FL34539 Page 1 of 3
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,installation, recommended use,or other product attributes that are not
specifically addressed herein.
CREEKj'[ c/o OWENS CORNING ROOFING AND ASPHALT LLC
it
TECHNICAL SERVICES, LLC TRI-BUILT Granular Underlayment
APPLICATION.
Roof Deck: The roof deck shall be constructed of closely fitted plywood sheathing for new or
existing construction. Deck shall be installed in accordance with FBC
requirements. Roof decks shall have no more than 1/8"gap at abutting joints.
Min.slope: 2:12 or in accordance in with FBC
Application: Prior to beginning installation, the underfayment shall be unrolled and allowed to
relax for a minimum of 3-5 minutes. The underlayment installation shall comply
with FBC Table 1507.1.1.1.
The underlayment shall be installed with the roll length parallel to the eave,starting
at the eave fold the underlayment away from eave onto itself. The underlayment
shall be installed direct-to-decking with the lower release backer removed and
pressed firmly into place to ensure complete contact with the deck. Repeat with
upper release backer. Overlap successive courses with minimum 3"side laps and
minimum 6°staggered end laps.
In steep-slope applications (>6:12), it is permissible to nail the underlayment 12-
inches on-center as needed(nails shall be installed perpendicular to deck with the
nail heads flush to the top surface of the underlayment).
For valley applications, the roll shall be applied centered along the valley prior to
installing the underlayment at the eave and overlapped a minimum of 6-inches.
For eave protection, the underlayment should extend to a point 18-inches beyond
the interior wall.
Min.Application Temperature: 40°F; Contact the manufacturer when installing at temperatures below the
minimum application temperature.
Allowable roof coverings: Mechanical attachment of.asphalt shingles and slate shingles shall be permitted in
accordance with the FBC..
OCR20001 FL34539 Page 2 of 3
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,installation, recommended use, or other product attributes that are not
specifically addressed herein.
i
szc CREEK BEACON SALES ACQUISITIONS,INC.
clo OWENS CORNING ROOFING AND ASPHALT LLC
TECHNICAL SERVICES, LLC TRI-BUILT Granular Underlayment
LIMITATIONS
1) This evaluation report is not for use in the HVHZ.
2) Fire Classification is not within the scope of this evaluation.
3) Wind uplift resistance in not within scope of this evaluation.
4) Installation of the evaluated product shall comply with this report,the FBC,and the manufacturers published
application instructions. Where discrepancies exist between these sources, the more restrictive and FBC
compliant installation detail shall prevail.
5) Deck substrates shall be dean, dry, and free from any irregularities and debris. All fasteners in the deck
shall be checked for protrusion and corrected prior to underlayment application.
6) The underlayment may be used as described in other current FBC product approval documents.
7) Roof coverings shall not be adhered directly to the underlayment. Roof coverings shall be mechanically
fastened through the underlayment to the roof deck.
8) The underlayment shall not be installed over existing roof coverings.
9) The underlayment shall be installed starting at the eave in horizontal layers such that the laps shed water
from the deck. The first layer shall cover the entire bottom edge of the deck. End laps shall be staggered a
minimum of 24-inches from the preceding course.
10) The underlayment shall be exposed on the roof deck for a maximum duration of 30 days.
11) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61 G20-3.
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P-E. have demonstrated compliance with the Florida Building
Code,7 h Edition(2020)as evidenced in the referenced documents submitted by the named manufacturer.
�,�PFtY R 2020.10.14.•pR/.,�
i�
'V
ENsF15.45.22
No 74021 10
Y{W•VIM•,1�W,0.�
_ *•• -04'00'
:1 STATE OF
.00 ..••,� P•;2�� Zachary R.Priest,P.E. .
'�,��s• O R 1'D.• �N`�`� Florida Registration No.74021
•,���S;�N A; ?`�� Organization No.ANE9641
CERTIFICATION OF INDEPENDENCE
CREEK Technical Services,LLC does not have,nor will it acquire,a financial interest in any company manufacturing or distributing products under this
evaluation.
CREEK Technical Services,LLC is not owned,operated,or controlled by any company manufacturing or distributing products under this evaluation.
Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any company manufacturing or distributing products under this evaluation.
Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product.
END OF REPORT
OCR20001 FL34539 Page 3 of 3
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
i