HomeMy WebLinkAboutProduct Approval Roofing Underlayments 12/10/21,9:39 AM Florida Building Code Online
BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications Contact Us .13 Product Approval
USER: Public User
d.0' r RECEIVED
Product Approval Menu > Product or Application Search >Application List> Application Detail
�C 2 21
FL# rFl_10626nR22_? St.Lucie County
Application Type Revision Permitting
Code Version 2020
Application Status Approved RECEIVED
Comments DEC 3 0 2021
Archived St.Lucie County
Permitting
Product Manufacturer GAF
Address/Phone/Email 1 Campus Drive
Parisppany, NJ 07054
(800) 766-3411
mstieh@gaf.com
Authorized Signature Robert Nieminen
Ireith@nemoetc.com
Technical Representative William Broussard
Address/Phone/Email 1 Campus Drive
Parsippany, NJ 07054
(800) 766-3411
TechnicalQuestionsGAF@gaf.com
Quality Assurance Representative
Address/Phone/Email
Category -.Roofhg'_;
Subcategory Underlayments'.
Compliance Method Evaluation Report from a Florida Registered Archil
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Robert Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 12/17/2021
Validated By John W. Knezevich, PE
Validation Checklist - Hardcopy Received
Certificate of Independence FL10626 R22 COI 2021 01 COI NIEMINEN.pdf
Referenced Standard and Year (of Standard) Standard
ASTM D1970
https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQWtDgtBNbEY5V%2boQYgnVE2RUHVOxKjvNQ3GJLgejWUj2ta%2bEA%3d%3d 1/2
12/10/21,9:39 AM Florida Building Code Online
ASTM D4533 (tear)
ASTM D4798 (.weathering)
ASTM D4869 (water transmission)
ASTM D5035 (tensile)
ASTM D6164
ASTM D6757
FM 4474
FRSA/TRI, 6th Edition
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 06/09/2021
Date Validated 06/11/2021
Date Pending FBC Approval 06/17/2021
Date Approved 08/10/2021
Summary of Products
FL # Model, Number or Name Description
10626.1 I GAF Roof Underlayments for use Roofing Underlayments for use in sloped roof syst
in FBC non-HVHZ jurisdictions
Limits of Use installation-.,Instructions
` Approved for use in HVHZ: No ' FL10626 R2 _ II 20. 21 06 09-17INAL ER GAF L
Approved for use outside HVHZ: Yes R22.Of
Impact Resistant: N/A Verified By: Robert Niemien 59166
Design Pressure: +N/A/-442.5 Created by Independent Third Party: Yes
1 Other: 1.) The design pressure-noted in this Evaluation Reports
application relates to one particular underlayment { FL10626 R22 AE 2021 06 09 FINAL ER GAF
system. Refer to ER Section 5.8.3 for details. 2.) Refer I R22.pdf
to ER Section 5 for other Limits of Use. i Created by Independent Third Party: Yes
Contact Us :: 2601 Blair Stone Road,Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copy
Lght 2007-2013 State of Florida. :: Privacy Statement :: Accessibility SA
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a pub
electronic mail to this entity. Instead,contact the office by phone or by traditional mail. If you have any questions, please cor
Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the I
if they have one.The emails provided maybe used for official communication with the licensee. However email addresses are
to supply a personal address, please provide the Department with an email address which can be made available to the pL
licensee under Chapter 455, F.S., please click here .
Product Approval Accepts:
H� M
Credit Card
Safe
hfps://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtBNbEY5V%2boQY9nVE2RUHV0icKjvNQ3GJLgejWUj2ta%2bEA%3d%3d 2/2
i
- - _ -- NEMO etc.
Certificate of Authorization#32455
353 Christian Street; Unit#13
Oxford,CT 06478
(203) 262-9245
ENGINEER EVALUATE TEST CONSULT
REPORTEVALUATION
GAF Evaluation Report 01506.04.08-R22
1Campus Drive FL10626-1122
Parsippany, NJ_ 07054 Date of Issuance:04/25/2008
(800)766-3411 Revision 22:06/09/2021
SCOPE:
This Evaluation Report.is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E.for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products
described herein have been evaluated for compliance with the 7th Edition(2020) Florida Building Code sections noted
herein. .
I cRIPT1oN: GqF Roof n meet us B Julri du:t olns
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein and FBC 1507.1.1.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes,the referenced
Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change.
Acceptance of our Evaluation Reports by the named client constitutes agreement to notify MEMO ETC, LLC of any
changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a
complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle:
ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMO I etc. Evaluated" may be
displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its
entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 9.
Prepared by:
Robert J.M. Nieminen,P.E. t="5�"`` �"``
._ The facsimile seal appearing was authorized by Robert.
Florida Registration No.59166 Florida DCAANE1983 '' s - "E Nieminen,P.E.on 06/09/2021.This does not serve as an
electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMO ETC,LLC is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen,P.E.are,in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
9)2019 NEMO ETC,LLC
ONEMOJetc.
ROOFING COMPONENT EVALUATION:
1. O.
Product Category: Roofing
Sub-Category: Underlayment
Compliance Statement: GAF Roof Underlayments,as produced by GAF, have demonstrated compliance with the
following sections of the 7th Edition(2020)Florida Building Code through testing in accordance with the following
Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth
herein.
2. STANDARDS:
�`n� y b +g._4"y�-tx s+ a`i^:,-+;•.� :Ff:a:.a,t,.. 2 t",k",a. �,.d, - i ^..;x '?
�1504.3.1 Wind resistance FM 4474 2011
1507.1.1,1507.2.4,1507.2.9.2/ Material standard ASTM D1970 2015
R905.1.1,R905.2.8.2
1507.1.1.1(2&3,Exception), Tear Strength ASTM D4533 2015
1507.1.1.1(5)/R905.1.1.1(2&3,
Exception),11905.1.1.1(5)
1507.1.1.1(2&3,Exception), Tensile strength ASTM D5035 2011
1507.1.1.1(5)/R905.1.1.1(2&3,
Exception),R905.1.1.1(5)
1507.1.1.1(5)./R905.1.1.1(5) Liquid water transmission ASTM D4869 2016
1507.1.1/R905.1.1 Material standard ASTM D6757 2016
1507.3.3,R905.3.3 Material standard FRSA/TRI,Sixth Edition 2018
1507.11.2 Material standard ASTM D6164 2011
TAS 110 Accelerated Weathering ASTM D4798 2011
3. REFERENCES:
Elit k F , Y t fi �F.xarrurtation _ ✓___ f Reference
ERD(TST 6049) ASTM D1623&FRSA/TRI(Slippage) G34150.08.11 11/14/2011
ERD(TST 6049) ASTM D6164(GA) G40630.01.14-2B 01/07/2014
ERD(TST 6049) ASTM D6164(GA) G46160.09.14-3A 09/09/2014
ERD(TST 6049) ASTM D1970(GA) GAF-SC13285.03.17-3 03/01/2017
ERD(TST 6049) ASTM D1970(GA) GAF-SC13285.03.17-4 03/01/2017
ERD(TST 6049) ASTM D1970(GA) GAF-SC13285.03.17-1 03/08/2017
ERD(TST6049) ASTM D1970(IN) GAF-SC16440.12.17 12/31/2017
Intertek(TST 1558) ASTM D4869(Dadra,India) F8549.02-106-18 11/08/2016
NEMO(TST 6049) Physical Properties(ON) 4q-GAF-19-SSMBB-03.A 05/13/2019
NEMO(TST6049) ASTM D1970 4j-FTS-20-SSUDL-01.A 12/01/2020
NEMO(TST 6049) ASTM D4798,TAS 103 4j-GAF-20-SSUDL-02.A 03/15/2021
NEMO(TST6049) ASTM D4798 4j-FTS-2I-SSUDL-02.A 06/09/2021
PRI(TST 5878) ASTM D1970(IN) GAF-324-02-01 11/30/2011
PRI(TST 5878) ASTM D226(OK) GAF-339-02-01 03/13/2012
PRI(TST 5878) ASTM D4798(NC) GAF-349-02-01 07/03/2012
PRI(TST5878) Wind Uplift GAF-434-02-01 09/16/2013
PRI(TST5878) Wind Uplift GAF-434-02-03 09/16/2013
PRI(TST5878) Wind Uplift GAF-434-02-04 09/16/2013
PRI(TST5878) ASTM D4533(various) GAF-818-02-01 12/05/2017
PRI(TST 5878) ASTM D1970(AL) MSA-047-02-01 04/11/2018
PRI(TST5878) ASTM D4533(LA) GAF-826-02-01 06/4/2018
PRI(TST5878) ASTM D4533(Dadra,India) GAF-847-02-01 06/4/2018
PRI(TST5878) ASTM D4533(Dadra,India) GAF-914-02-01 04/10/2019
PRI(TST 5878) ASTM D4533,D5035(VA) 376T0012 07/15/2019
PRI(TST5878) ASTM D4533(Umerkui Kilvani,India) 376T0018 07/31/2019
PRI(TST5878) ASTM D4533(Parzai,India) 376T0018 07/31/2019
NEMO ETC,LLC Evaluation Report 01506.04.08-1122
Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION FL10626-R22
GAF Roof Underlayments Revision 22:06/09/2021
Page 2 of 9
i
ONEMO etc.
„--- r. -fv x � 'e. h �„,: a-,.Y'Y^".,.�,"� �,.��: {...'.�,�,�' c"'• S .Fix"'3. �"'�^ -,kk�• .,arra.'��-`J�'r"z` r^t:��"_�� '
PRI(TST 5878) ASTM D1970(AR) ~376T0032 10/22/2019
PRI(TST 5878) ASTM D226(S-CA) 376T0054 02/18/2020
PRI'(TST 5878) ASTM D4533(Gujarat,India) 376T0058 02/18/2020
PRI(TST 5878) ASTM D5035(various) 376TO103 09/11/2020
PRI(TST 5878) ASTM D4533,D5035(Rajasthan,India) 376TO111 12/22/2020
PRI(TST 5878) ASTM D4533,D5035(Gujarat,India) 376T0113. 12/22/2020
UL(TST 1740) ASTM D6757.(TX) 02NK22569 06/04/2002
PRI(TST 5878) ASTM D5035(Gujarat,India) 376TO146 03/11/2021
PRI(TST 5878) ASTM D4533,D5035(Rajasthan,India) 376TO161 05/07/2021
UL(TST 1740) ASTM D6757(NC) 10NK11990 05/18/2011
NEMO ETC Traceability FBC Cross-Listing 04/22/2020
NEMO Traceability FBC Cross-Listing 04/08/2021
UL,LLC(QUA 9625) Quality Control Service Confirmation 03/23/2021
UL,LLC(QUA 9625) Quality Control Service Confirmation(AL) 05/04/2020
UL,LLC(QUA 9625) Quality Control Florida BCIS Current
4. PRODUCT DESCRIPTION:
'`';n k�. �..r: ;;;a"` ^�t.,�,z•�g •x' -��*:.;7 ��"''�'4Yy},��.(r�-•r-��-i.�s»-urs,.�
�T146 it al Stand��Y_ ''� :'... ,�%<, - "T tf�L�n F,:teJL '�. ,�..•vm:.
4.1 GAF Extended Dry-In Membrane ASTM D1970 Langley,BC Canada
4.2 Liberty'" SBS Self-Adhering Base/Ply ASTM D1970 Mt.Vernon,IN
Sheet Savannah,GA
4.3 StormGuard°Film-Surfaced Leak Barrier ASTM D1970 Mt.Vernon,IN
Savannah,GA
Arkadelphia,AR
4.4 WeatherWatch°Mineral-Surfaced Leak ASTM D1970 Mt.Vernon,IN
Barrier Savannah,GA
Tuscaloosa,AL
Deck-Armor'""Premium Breathable Roof 1507.1.1.1(2&3,Exception)/
4.5 Deck Protection R905.1.1.1(2&3,Exception) Dadra, India
Dadra, India
Gujarat,India
FeltBuster'"Synthetic Roofing Felt 1507.1.1.1(2&3,Exception), (CPP)Rajasthan,India
4.6 (formerly FeltBuster""High-Traction Synthetic 1507.1.1.1(5)/R905.1.1.1(2&3, (MIP)Rajasthan,India
Roofing Felt) Exception),R905.1.1.1(5)
Richmond,VA
Spartanburg,SC
4.7 Shingle-Mate®Roof Deck Protection ASTM D226,Type II(Table 1) Pryor,OK
Shafter,CA
1507.1.1.1(2&3,Exception)/
4.8 StormSafe'""Anchor Sheet R905.1.1.1(2&3,Exception) North Bay,ON
Dadra, India
Tiger Paw'""Premium Roof Deck 1507.1.1.1(2&3,Exception) Gujarat,India
4.9 Protection(formerly Tiger Paw-Roof Deck R905.1.1.1(2&3,Exception) Parzai, India
Protection)
Umerkui Kilvani,India
4.10 VersaShield° Fire-Resistant Roof Deck ASTM D6757 Conover,NC
Protection
4.11 Ruberoid®Mop Granule ASTM D6164 Savannah,GA
FRSA/TRI 09-18
ASTM D6164
4.12 Ruberoid®Mop Granule FR FRSA/TRI 09-18 Savannah,GA
NEMO ETC,LLC Evaluation Report 01506.04.08-R22
Certificate of Authorization N32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION FL10626-1122
GAF Roof Underlayments Revision 22:06/09/2021
Page 3 of 9
ONEMO etc.
5. LIMITATIONS:
5.1 This is a building code.evaluation. Neither NEMO ETC;LLC nor Robert Nieminen, P.E.are,in any way,the Designer
of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami-
Dade Counties).
5.3 This Evaluation Report pertains to above-deck roof components. Roof decks and structural members shall be in
accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and
limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations
concerning the use of foam plastic insulation.
5.5 GAF Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced
within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for
- approval based on this evaluation combined with supporting data for the prepared roof covering.
5.6 Allowable Roof Covers: .
cis 4, e1B Ron VERQPI[�. a .
.• w
�k"A
',"*
`' Y3FV@" z r€2 f.. .0 ss^ h11► ..3�..Z E t
•z. � - �,��Rr ,s,?IlflTgl�SX;, ��' �"-^s-.�.;, `�.. ,&#� -�"��a110 z p$�'`'�>sx �`�'�>" s',� 18.4 `'.1�
r -�, .F h s w: 'x- ,s r .x,¢ _4"• _ 'fit.
fith e5
F
u
Yes Yes
GAF Extended Dry-In Membrane Yes No No Yes Yes Yes (joint strips, (joint strips,
1507.1.1.3/ 1507.1.1.3/
R905.1.1.31 R905.1.1.3) -
Yes Yes
Liberty'"SBS Self-Adhering (joint strips, (joint strips,
Yes No No No No No Base/Ply Sheet 1507.1.1.3/ 1507.1.1.3/
R905.1.1.3) R905.1.1.3)
Yes Yes
StormGuardm Film-Surfaced Leak
Barrier Yes No No Yes Yes Yes (loin[strips, (joint strips,
1507.1.1.3/ 1507.1.1.3/
R905.1.1.3) R905.1.1.3)
Yes Yes
WeatherWatch®Mineral-Surfaced
Leak Barrier Yes No No No No No (joint57.1.1.3/ps, (joint strips,
1507.1.1.3/ 1507.1.1.3/
R905.1.1.3) R905.1.1.3)
Deck-Armor'"Premium Breathable Yes No No Yes Yes Yes No No
Roof Deck Protection
FeltBuster—Synthetic Roofing Felt Yes No No No No No No No
Shingle-Mate°Roof Deck
Yes No No No No No No No
Protection
Tiger Paw—Premium Roof Deck Yes No No Yes Yes Yes No No
Protection
VersaShield®Fire-Resistant Roof Yes No No No No No No No
Deck Protection
Yes Yes
Ruberoidm Mop Granule No (Cap Sheet in (Cap Sheet in No No No No No
2-ply system)
2-ply system) See 5.6.1
Yes Yes
Ruberoidm Mop Granule FR No (Cap Sheet in (Cap Sheet in No No No No No
2-ply system) 2-ply system)
See 5.6.1
NEMO ETC,LLC Evaluation Report 01506.04.08-R22
Certificate of Authorization N32455 7TH EDITION(2020)FBC NON-HVHZ EVALUATION FL10626-1122
GAF Roof Underlayments Revision 22:06/09/2021
Page 4 of 9
NEMO etc.
5.6.1 Adhesive-set is limited to use of following underlayment/tile-adhesive combinations.
FI1EIII Up f10N5
u n. L z z'" '* e.: k'-v r �" �' +�g ,c '^e' TMkk: ,rd•t'. + n" `� -,fi,K a0 55-3 y
t r 22
s ti �' r Ad(f 11lB v3 iO�id pCtt$iBCt pQf tarull
3
Ruberoid°Mop Granule;Ruberoid®Mop Granule FR Dupont"Tile Bond"Roof Tile Adhesive" FL22525
5.7 Allowable Substrates:
BE
d � t•rid: i� x�P s r Y'fi's2` � 9�.'r{4 i Syti.:+� �" £Y i -«3;f'dfi .aE"•7X'.�,7 _,�'= 3a-S
S,-•,< } �Ulttieriayment _� ";. ppl�s�tioK '^ ��'-`FnmeC u z i;:`�",..r. .,,�sE1�Cdt8S"`4 '`���i,� .E'
GAF Extended Dry-In Membrane self-adhering None plywood
Liberty-SBS Self-Adhering Base/Ply Sheet
StormGuard'Film-Surfaced Leak Barrier self-adhering (Optional) plywood
ASTM D41
Weather Watch®Mineral-Surfaced Leak Barrier
Liberty'"SBS Self-Adhering Base/Ply Sheet
StormGuard'Film-Surfaced Leak Barrier self-adhering None ASTM D226 felt,Type II
Weather Watch'Mineral-Surfaced Leak Barrier
Liberty'"^SBS Self-Adhering Base/Ply Sheet
StormGuard'Film-Surfaced Leak'Barrier self-adhering ASTM D41 metal(flashing metal,valley metal,
etc.)
Weather Watch'Mineral-Surfaced Leak Barrier
Ruberoid'Mop Granule
hot asphalt ASTM D41 structural concrete
Ruberoid'Mop Granule FR
Ruberoid'Mop Granule hot asphalt None GAFGLAS'#80 Ultima'"" Base Sheet
Ruberoid'Mop Granule FR or Ruberoid'20 Smooth
5.8 Attachment Limitations:
5.8.1 For use under mechanically attached NON-TILE prepared roof coverings,attachment shall be in accordance with
the manufacturer's installation instructions,but—for mechanically attached underlayments or base sheets-not
less than FBC 1507.1.1 or R905.1.1.
5.8.2 For use under tile roof systems, attachment shall be in accordance with the manufacturer's installation
instructions, but—for mechanically attached base sheets-not less than:
• FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A,
Table 1 (for Two-Ply Asphalt Applied Hot Mop Underlayment)
or
• -Section 5.8.3 herein (for other underlayment systems).
5.8.3 Wind Resistance for Underlayment Systems in Tile Roof Applications:
The following wind uplift limitations apply to underlayment systems that are not prescriptive in the FRSA/TRI
Florida High Wind Concrete and Clay Roof Tile Installation Manual,Sixth Edition. The Maximum Design Pressure
is the result of testing for wind load resistance based on allowable wind loads,and reflects the ultimate passing.
pressure divided by 2(the 2 to 1 margin of safety per FBC 1504.9 has already been applied).
5.8.3.1 Direct-to-Deck:
The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI
Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1A or the
critical (highest) design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3.
1 Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
NEMO ETC,LLC Evaluation Report 01506.04.08-R22
Certificate ofAuthorization#32455 7-EDITION.(2020)FBC NON-HVHZ EVALUATION FL10626-1122
GAF Roof Underlayments Revision 22:06/09/2021
Page 5 of 9
ONEMOJetc. . ' .
#1 Maximum Design Pressure=-442.5 psf.
to satisfaction of Authority Having
Deck: Min.2 500 psi structural concrete to meet project requirementsY g
e
Jurisdiction
Base Sheet: GAFGLAS 475 Base Sheet,Tri-Ply 475 Base Sheet,GAFGLAS#80 Ultima Base Sheet,GAFGLAS Ply 4,
Tri-Ply Ply 4 or GAFGLAS Flex Ply 6 applied in full mopping of ASTM D312,Type IV hot asphalt at 20
to 25 Ibs/square.
Cap Sheet: Ruberoid® Mop Granule or Ruberoid° Mop Granule FR applied in full mopping of ASTM D312,Type
IV hot asphalt at 20 to 25 Ibs/square,
5.8.3.2 Mechanically-Attached Base Sheet:
The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI
Florida High Wind Concrete and Clay Roof Tile installation Manual, Sixth Edition, Appendix A, Table 1A or the
critical (highest) design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3.
Alternatively,the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1
design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. Elevated pressure zones
shall employ an attachment density designed by a qualified design professional to resist the elevated pressure
criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing
Application Standard RAS 117. Assemblies marked with an asterisk* carry the limitations set forth in Section
2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (February 2020)for enhancements.
#2 Maximum Design Pressure=-45 psf.
Having
19 32-inch plywood to meet project requirements to satisfaction of Authority H g
Deck: Min. / p y p 1 q
Jurisdiction.
Base Sheet: GAFGLAS' #80 Ultimar" Base Sheet or Ruberoid® 20 Smooth mechanically attached with 12 ga.,
min. 1.25-inch long ring shank nails through 32 ga., 1-5/8-inch diameter tin caps spaced 9-inch o.c.
at the min. 4-inch wide side laps and 9-inch o.c. at two (2), equally spaced,staggered center rows
in the field of the sheet.
Cap Sheet: Ruberoid° Mop Granule or Ruberoid° Mop Granule FR applied in full mopping of ASTM D312,Type
IV hot asphalt at 20 to 25 Ibs/square.
#3 Maximum Design Pressure=-75 psf.
Deck: Min. 19/32-inch plywood.to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: GAFGLAS' #80 Ultima'"^ Base Sheet or Ruberoid® 20 Smooth mechanically attached with 12 ga.,
min. 1.25-inch long ring shank nails through 32 ga., 1-5/8-inch diameter tin caps spaced 8-inch o.c.
at the min.4-inch wide side laps and 8-inch o.c. at three(3),equally spaced,staggered center rows
in the field of the sheet.
Cap Sheet: Ruberoid' Mop Granule or Ruberoid"Mop Granule FR applied in full mopping of ASTM D312,Type
IV hot asphalt at 20 to 25 Ibs/square.
#4 Maximum Design Pressure=-97.5 psf.
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: GAFGLAS' #80 UltimaT' Base Sheet or Ruberoid' 20 Smooth mechanically attached with 11 ga.,
min. 1.25-inch long ring shank nails through 32 ga., 1-5/8-inch diameter tin caps spaced 4-inch o.c.
at the min.2-inch wide side laps and 4-inch o.c. at four(4),equally spaced center rows in the field
of the sheet.
Cap Sheet: Ruberoid' Mop Granule or Ruberoid' Mop Granule FR applied in full mopping of ASTM D312,Type
IV hot asphalt at 20 to 25 Ibs/square.
NEMO ETC,LLC Evaluation Report 01506.04.08-1122
Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION FL10626-R22
GAF Roof Underlayments Revision 22:06/09/2021
Page 6 of 9
is
ONEM01i
5.9 Exposure Limitations:
Ly>wnrt TW
•'�` ,?' u-
�
�U�Q.ri0.
� t f i.� .�� �,� -s �� ,� �,�.r'-�sy.�� v k*, y,f �,�' � e '�t� �t � _'�r��dttOE�� �.-• +sue' � .�,�, "�� ��'
'? � ,G s. �. ` • �'r'3 z-fan, �L �' JtWV �
Deck-Armor'"Premium Breathable Roof Deck Protection,FeltBusterT"Synthetic
Roofing Felt,Shingle-Mate® Roof Deck Protection,StormSafe'm Anchor Sheet,Tiger
Paw'"Premium Roof Deck Protection,VersaShield°Fire-Resistant Roof Deck Mechanically attached 30
Protection,Liberty'"SBS Self-Adhering Base/Ply Sheet,StormGuard"Film-Surfaced
Leak Barrier and WeatherWatch® Mineral-Surfaced Leak Barrier
GAF Extended Dry-In Membrane Mechanically attached 180
Adhesive-set tile roof system 180
Ruberoid°Mop Granule and Ruberoid®Mop Granule FR
Mechanically attached UNLIMITED
5.10 Tile Slippage Limitations: When loading roof tiles on the underlayment in direct-deck tile roof assemblies, the
maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during
loading of the roof tiles.
MY lillill2
1E ' ;4'Tt�S AP.Ir6EUMtThTIQ 4soUi 3TttECT)0 � ,,;
�_..
Under ayme t` TiteProfife , �StagiKg Method NCa of 5tagmg 51ope
..a. ._. .a.... « .,. ..�. .4 .
Flat Max.10-tile stack 4:12
Ruberoid®Mop Granule Flat Max.6-tile stack(4 over 2) 5:12
Lugged Max.10-tile stack 5:12
Ruberoid®Mop Granule FIR Fiat or Lugged Max.6-tile stack(4 over 2) 5:12
Lugged Max.10-tile stack 4:12
INSTALLATION:6.
6.1 GAF Roof Underlayments shall be installed in accordance with GAF published installation instructions subject to
the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to
remove any dust and debris prior to application and prime the substrate(if applicable).
� �" � "" �. , •- _ s � r
6:3 ' t!e 0 orTM Pre to Breatha'Lu R � Uec ti otecti nor ej<P w P em u R ec rc►tect. n
..:� ,. _
6.3.1 Shall be installed in compliance with requirements for a synthetic underlayment in FBC 1507.1.1.1(2,Exception)
or 1507.1.1.1(3,Exception)or FBC Residential R905.1.1.1(2,Exception)or R905.1.1.1(3,Exception)for the type
of prepared roof covering to be installed,and the manufacturer's installation instructions. FBC requirements take
precedence over the manufacturer's installation instructions.
6.4.1 Shall.be installed in compliance with requirements for a synthetic underlayment in FIX 1507.1.1.1(2,Exception),
1507.1.1.1(3, Exception) or 1507.1.1.1(5) or Fill Residential R905.1.1.1(2, Exception),R905.1.1.1(3, Exception)
or R905.1.1.1(5) for the type of prepared roof covering to be installed, and the manufacturer's installation
instructions. FBC requirements take precedence over the manufacturer's installation instructions.
MEMO ETC,LLC Evaluation Report 01506.04.08-11122
Certificate of Authorization N324SS 7-EDITION(2020)FBC NON-HVHZ EVALUATION FL10626-11122
GAF Roof Underlayments Revision 22:06/09/2021
Page 7 of 9
NEMO etc.
Sto "'Anchor Sheet•
6.5.1 StormSafe'"Anchor Sheet is limited to use as a mechanically attached base layer in 2-ply underlayment systems.
6.5.2 Shall be installed in compliance with requirements for a synthetic underlayment in FBC 1507.1.1.1(2,Exception)
or 1507.1.1.1(3,Exception)or FBC Residential R905.1.1.1(2,Exception)or R905.1.1.1(3,Exception)for the type
of prepared roof covering to be installed,and the manufacturer's installation instructions. FBC requirements take
precedence over the manufacturer's installation instructions.
6.5.3 One the same day, install LibertyT" SBS Self-Adhering Base/Ply; StormGuard® Film-Surfaced Leak Barrier or
WeatherWatch° Mineral-Surfaced Leak Barrier over the StormSafeW Anchor Sheet.
fimgle-Mate• oof`Deek
6.6.1 Shall be installed in compliance with requirements for an approved mechanically attached underlayment (ASTM
D226,Type II)in FBC Table 1507.1.1.1 or FBC Residential Table R905.1.1.1 for the type of prepared roof covering
to be installed, and the manufacturer's installation instructions. FBC requirements take precedence over the
manufacturer's installation instructions.
—11'
6. 1lersa5hietd•Fire-Resi nt Roof De k Pr to ion. MUM
6.7;1 Shall be installed in compliance with requirements for an approved mechanically attached underlayment (ASTM
D6757) in FBC Table 1507.1.1.1 or FBC Residential Table R905.1.1.1 for the type of prepared roof covering to be
installed, and the manufacturer's installation instructions. FBC requirements take precedence over the
manufacturer's installation instructions.
8 GAF Extended Dry-in embrane,Liberty
Barrier o�Weather.; SB_SSe Mail m- ee
M FSaracdekBarrier: y m
6.8.1 Shall be installed in compliance with requirements for an approved self-adhering underlayment(ASTM D1970)in
FBC 1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering
to be installed,and the manufacturer's installation instructions.
6.8.2 Back-nailing is required. Back-nailing shall consist of Approved cap nails spaced 18-inch o.c.,.encapsulated within
min.4-inch side laps.
6.8.3 When installed over a mechanically attached, FBC Approved ASTM D226 Type II felt,the felt shall be fastened in
accordance with FBC 1507.1.1 or R905.1.1.
6.8.4 GAF Extended Dry-In Membrane, LibertyTm SBS Self-Adhering Base/Ply Sheet,StormGuard® Film-Surfaced Leak
Barrier or WeatherWatch® Mineral-Surfaced Leak Barrier may be installed as a secondary water barrier using
minimum 4-inch wide rolls to seal plywood deck joints prior to installation of the primary underlayment system.
6:9 "Rube oid•.Mop�vra�nu e;Ruberoid•Mop Grano a ,R-
6.9.1 Shall be installed in compliance with requirements as an alternate to the "Hot Asphalt Applied Cap Sheet" in the
"Two Ply System" in the FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth .
Edition,and the manufacturer's installation instructions.
6.9.2 Refer to Section 5.8 herein for attachment limitations.
6.9.3 Refer to Table 4 for the staging limitations.
NEMO ETC,LLC Evaluation Report 01506.04.08-R22
Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION FL10626-R22
GAF Roof Underlayments Revision 22:06/09/2021
Page 8 of 9
M- ---'-,NEM0 etc.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this
product.
8. MANUFACTURING PLANTS:
Contact the named QA entity for manufacturing facilities covered by F.A.C.Rule 61G20-3 QA requirements. Refer
to Section 4 herein for products and production locations having met codified material standards.
QUALITY9.
UL, LLC.—QUA9625; (414)248-6409; karen.buchmann@ul.com
-END OF EVALUATION REPORT-
i
NEMO ETC,LLC Evaluation Report 01506.04.08-R22
Certificate of Authorization#32455 7TH EDITION(2020)FBC NON-HVHZ EVALUATION F1.10626-1122
GAF Roof Underlayments Revision 22:06/09/2021