Loading...
HomeMy WebLinkAboutProduct Approval Roofing Underlayments 12/10/21,9:39 AM Florida Building Code Online BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications Contact Us .13 Product Approval USER: Public User d.0' r RECEIVED Product Approval Menu > Product or Application Search >Application List> Application Detail �C 2 21 FL# rFl_10626nR22_? St.Lucie County Application Type Revision Permitting Code Version 2020 Application Status Approved RECEIVED Comments DEC 3 0 2021 Archived St.Lucie County Permitting Product Manufacturer GAF Address/Phone/Email 1 Campus Drive Parisppany, NJ 07054 (800) 766-3411 mstieh@gaf.com Authorized Signature Robert Nieminen Ireith@nemoetc.com Technical Representative William Broussard Address/Phone/Email 1 Campus Drive Parsippany, NJ 07054 (800) 766-3411 TechnicalQuestionsGAF@gaf.com Quality Assurance Representative Address/Phone/Email Category -.Roofhg'_; Subcategory Underlayments'. Compliance Method Evaluation Report from a Florida Registered Archil Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Robert Nieminen Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 12/17/2021 Validated By John W. Knezevich, PE Validation Checklist - Hardcopy Received Certificate of Independence FL10626 R22 COI 2021 01 COI NIEMINEN.pdf Referenced Standard and Year (of Standard) Standard ASTM D1970 https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQWtDgtBNbEY5V%2boQYgnVE2RUHVOxKjvNQ3GJLgejWUj2ta%2bEA%3d%3d 1/2 12/10/21,9:39 AM Florida Building Code Online ASTM D4533 (tear) ASTM D4798 (.weathering) ASTM D4869 (water transmission) ASTM D5035 (tensile) ASTM D6164 ASTM D6757 FM 4474 FRSA/TRI, 6th Edition Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 06/09/2021 Date Validated 06/11/2021 Date Pending FBC Approval 06/17/2021 Date Approved 08/10/2021 Summary of Products FL # Model, Number or Name Description 10626.1 I GAF Roof Underlayments for use Roofing Underlayments for use in sloped roof syst in FBC non-HVHZ jurisdictions Limits of Use installation-.,Instructions ` Approved for use in HVHZ: No ' FL10626 R2 _ II 20. 21 06 09-17INAL ER GAF L Approved for use outside HVHZ: Yes R22.Of Impact Resistant: N/A Verified By: Robert Niemien 59166 Design Pressure: +N/A/-442.5 Created by Independent Third Party: Yes 1 Other: 1.) The design pressure-noted in this Evaluation Reports application relates to one particular underlayment { FL10626 R22 AE 2021 06 09 FINAL ER GAF system. Refer to ER Section 5.8.3 for details. 2.) Refer I R22.pdf to ER Section 5 for other Limits of Use. i Created by Independent Third Party: Yes Contact Us :: 2601 Blair Stone Road,Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copy Lght 2007-2013 State of Florida. :: Privacy Statement :: Accessibility SA Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a pub electronic mail to this entity. Instead,contact the office by phone or by traditional mail. If you have any questions, please cor Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the I if they have one.The emails provided maybe used for official communication with the licensee. However email addresses are to supply a personal address, please provide the Department with an email address which can be made available to the pL licensee under Chapter 455, F.S., please click here . Product Approval Accepts: H� M Credit Card Safe hfps://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtBNbEY5V%2boQY9nVE2RUHV0icKjvNQ3GJLgejWUj2ta%2bEA%3d%3d 2/2 i - - _ -- NEMO etc. Certificate of Authorization#32455 353 Christian Street; Unit#13 Oxford,CT 06478 (203) 262-9245 ENGINEER EVALUATE TEST CONSULT REPORTEVALUATION GAF Evaluation Report 01506.04.08-R22 1Campus Drive FL10626-1122 Parsippany, NJ_ 07054 Date of Issuance:04/25/2008 (800)766-3411 Revision 22:06/09/2021 SCOPE: This Evaluation Report.is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E.for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 7th Edition(2020) Florida Building Code sections noted herein. . I cRIPT1oN: GqF Roof n meet us B Julri du:t olns LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein and FBC 1507.1.1. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes,the referenced Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change. Acceptance of our Evaluation Reports by the named client constitutes agreement to notify MEMO ETC, LLC of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle: ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMO I etc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 9. Prepared by: Robert J.M. Nieminen,P.E. t="5�"`` �"`` ._ The facsimile seal appearing was authorized by Robert. Florida Registration No.59166 Florida DCAANE1983 '' s - "E Nieminen,P.E.on 06/09/2021.This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC,LLC is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen,P.E.are,in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 9)2019 NEMO ETC,LLC ONEMOJetc. ROOFING COMPONENT EVALUATION: 1. O. Product Category: Roofing Sub-Category: Underlayment Compliance Statement: GAF Roof Underlayments,as produced by GAF, have demonstrated compliance with the following sections of the 7th Edition(2020)Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. 2. STANDARDS: �`n� y b +g._4"y�-tx s+ a`i^:,-+;•.� :Ff:a:.a,t,.. 2 t",k",a. �,.d, - i ^..;x '? �1504.3.1 Wind resistance FM 4474 2011 1507.1.1,1507.2.4,1507.2.9.2/ Material standard ASTM D1970 2015 R905.1.1,R905.2.8.2 1507.1.1.1(2&3,Exception), Tear Strength ASTM D4533 2015 1507.1.1.1(5)/R905.1.1.1(2&3, Exception),11905.1.1.1(5) 1507.1.1.1(2&3,Exception), Tensile strength ASTM D5035 2011 1507.1.1.1(5)/R905.1.1.1(2&3, Exception),R905.1.1.1(5) 1507.1.1.1(5)./R905.1.1.1(5) Liquid water transmission ASTM D4869 2016 1507.1.1/R905.1.1 Material standard ASTM D6757 2016 1507.3.3,R905.3.3 Material standard FRSA/TRI,Sixth Edition 2018 1507.11.2 Material standard ASTM D6164 2011 TAS 110 Accelerated Weathering ASTM D4798 2011 3. REFERENCES: Elit k F , Y t fi �F.xarrurtation _ ✓___ f Reference ERD(TST 6049) ASTM D1623&FRSA/TRI(Slippage) G34150.08.11 11/14/2011 ERD(TST 6049) ASTM D6164(GA) G40630.01.14-2B 01/07/2014 ERD(TST 6049) ASTM D6164(GA) G46160.09.14-3A 09/09/2014 ERD(TST 6049) ASTM D1970(GA) GAF-SC13285.03.17-3 03/01/2017 ERD(TST 6049) ASTM D1970(GA) GAF-SC13285.03.17-4 03/01/2017 ERD(TST 6049) ASTM D1970(GA) GAF-SC13285.03.17-1 03/08/2017 ERD(TST6049) ASTM D1970(IN) GAF-SC16440.12.17 12/31/2017 Intertek(TST 1558) ASTM D4869(Dadra,India) F8549.02-106-18 11/08/2016 NEMO(TST 6049) Physical Properties(ON) 4q-GAF-19-SSMBB-03.A 05/13/2019 NEMO(TST6049) ASTM D1970 4j-FTS-20-SSUDL-01.A 12/01/2020 NEMO(TST 6049) ASTM D4798,TAS 103 4j-GAF-20-SSUDL-02.A 03/15/2021 NEMO(TST6049) ASTM D4798 4j-FTS-2I-SSUDL-02.A 06/09/2021 PRI(TST 5878) ASTM D1970(IN) GAF-324-02-01 11/30/2011 PRI(TST 5878) ASTM D226(OK) GAF-339-02-01 03/13/2012 PRI(TST 5878) ASTM D4798(NC) GAF-349-02-01 07/03/2012 PRI(TST5878) Wind Uplift GAF-434-02-01 09/16/2013 PRI(TST5878) Wind Uplift GAF-434-02-03 09/16/2013 PRI(TST5878) Wind Uplift GAF-434-02-04 09/16/2013 PRI(TST5878) ASTM D4533(various) GAF-818-02-01 12/05/2017 PRI(TST 5878) ASTM D1970(AL) MSA-047-02-01 04/11/2018 PRI(TST5878) ASTM D4533(LA) GAF-826-02-01 06/4/2018 PRI(TST5878) ASTM D4533(Dadra,India) GAF-847-02-01 06/4/2018 PRI(TST5878) ASTM D4533(Dadra,India) GAF-914-02-01 04/10/2019 PRI(TST 5878) ASTM D4533,D5035(VA) 376T0012 07/15/2019 PRI(TST5878) ASTM D4533(Umerkui Kilvani,India) 376T0018 07/31/2019 PRI(TST5878) ASTM D4533(Parzai,India) 376T0018 07/31/2019 NEMO ETC,LLC Evaluation Report 01506.04.08-1122 Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION FL10626-R22 GAF Roof Underlayments Revision 22:06/09/2021 Page 2 of 9 i ONEMO etc. „--- r. -fv x � 'e. h �„,: a-,.Y'Y^".,.�,"� �,.��: {...'.�,�,�' c"'• S .Fix"'3. �"'�^ -,kk�• .,arra.'��-`J�'r"z` r^t:��"_�� ' PRI(TST 5878) ASTM D1970(AR) ~376T0032 10/22/2019 PRI(TST 5878) ASTM D226(S-CA) 376T0054 02/18/2020 PRI'(TST 5878) ASTM D4533(Gujarat,India) 376T0058 02/18/2020 PRI(TST 5878) ASTM D5035(various) 376TO103 09/11/2020 PRI(TST 5878) ASTM D4533,D5035(Rajasthan,India) 376TO111 12/22/2020 PRI(TST 5878) ASTM D4533,D5035(Gujarat,India) 376T0113. 12/22/2020 UL(TST 1740) ASTM D6757.(TX) 02NK22569 06/04/2002 PRI(TST 5878) ASTM D5035(Gujarat,India) 376TO146 03/11/2021 PRI(TST 5878) ASTM D4533,D5035(Rajasthan,India) 376TO161 05/07/2021 UL(TST 1740) ASTM D6757(NC) 10NK11990 05/18/2011 NEMO ETC Traceability FBC Cross-Listing 04/22/2020 NEMO Traceability FBC Cross-Listing 04/08/2021 UL,LLC(QUA 9625) Quality Control Service Confirmation 03/23/2021 UL,LLC(QUA 9625) Quality Control Service Confirmation(AL) 05/04/2020 UL,LLC(QUA 9625) Quality Control Florida BCIS Current 4. PRODUCT DESCRIPTION: '`';n k�. �..r: ;;;a"` ^�t.,�,z•�g •x' -��*:.;7 ��"''�'4Yy},��.(r�-•r-��-i.�s»-urs,.� �T146 it al Stand��Y_ ''� :'... ,�%<, - "T tf�L�n F,:teJL '�. ,�..•vm:. 4.1 GAF Extended Dry-In Membrane ASTM D1970 Langley,BC Canada 4.2 Liberty'" SBS Self-Adhering Base/Ply ASTM D1970 Mt.Vernon,IN Sheet Savannah,GA 4.3 StormGuard°Film-Surfaced Leak Barrier ASTM D1970 Mt.Vernon,IN Savannah,GA Arkadelphia,AR 4.4 WeatherWatch°Mineral-Surfaced Leak ASTM D1970 Mt.Vernon,IN Barrier Savannah,GA Tuscaloosa,AL Deck-Armor'""Premium Breathable Roof 1507.1.1.1(2&3,Exception)/ 4.5 Deck Protection R905.1.1.1(2&3,Exception) Dadra, India Dadra, India Gujarat,India FeltBuster'"Synthetic Roofing Felt 1507.1.1.1(2&3,Exception), (CPP)Rajasthan,India 4.6 (formerly FeltBuster""High-Traction Synthetic 1507.1.1.1(5)/R905.1.1.1(2&3, (MIP)Rajasthan,India Roofing Felt) Exception),R905.1.1.1(5) Richmond,VA Spartanburg,SC 4.7 Shingle-Mate®Roof Deck Protection ASTM D226,Type II(Table 1) Pryor,OK Shafter,CA 1507.1.1.1(2&3,Exception)/ 4.8 StormSafe'""Anchor Sheet R905.1.1.1(2&3,Exception) North Bay,ON Dadra, India Tiger Paw'""Premium Roof Deck 1507.1.1.1(2&3,Exception) Gujarat,India 4.9 Protection(formerly Tiger Paw-Roof Deck R905.1.1.1(2&3,Exception) Parzai, India Protection) Umerkui Kilvani,India 4.10 VersaShield° Fire-Resistant Roof Deck ASTM D6757 Conover,NC Protection 4.11 Ruberoid®Mop Granule ASTM D6164 Savannah,GA FRSA/TRI 09-18 ASTM D6164 4.12 Ruberoid®Mop Granule FR FRSA/TRI 09-18 Savannah,GA NEMO ETC,LLC Evaluation Report 01506.04.08-R22 Certificate of Authorization N32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION FL10626-1122 GAF Roof Underlayments Revision 22:06/09/2021 Page 3 of 9 ONEMO etc. 5. LIMITATIONS: 5.1 This is a building code.evaluation. Neither NEMO ETC;LLC nor Robert Nieminen, P.E.are,in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami- Dade Counties). 5.3 This Evaluation Report pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning the use of foam plastic insulation. 5.5 GAF Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for - approval based on this evaluation combined with supporting data for the prepared roof covering. 5.6 Allowable Roof Covers: . cis 4, e1B Ron VERQPI[�. a . .• w �k"A ',"* `' Y3FV@" z r€2 f.. .0 ss^ h11► ..3�..Z E t •z. � - �,��Rr ,s,?IlflTgl�SX;, ��' �"-^s-.�.;, `�.. ,&#� -�"��a110 z p$�'`'�>sx �`�'�>" s',� 18.4 `'.1� r -�, .F h s w: 'x- ,s r .x,¢ _4"• _ 'fit. fith e5 F u Yes Yes GAF Extended Dry-In Membrane Yes No No Yes Yes Yes (joint strips, (joint strips, 1507.1.1.3/ 1507.1.1.3/ R905.1.1.31 R905.1.1.3) - Yes Yes Liberty'"SBS Self-Adhering (joint strips, (joint strips, Yes No No No No No Base/Ply Sheet 1507.1.1.3/ 1507.1.1.3/ R905.1.1.3) R905.1.1.3) Yes Yes StormGuardm Film-Surfaced Leak Barrier Yes No No Yes Yes Yes (loin[strips, (joint strips, 1507.1.1.3/ 1507.1.1.3/ R905.1.1.3) R905.1.1.3) Yes Yes WeatherWatch®Mineral-Surfaced Leak Barrier Yes No No No No No (joint57.1.1.3/ps, (joint strips, 1507.1.1.3/ 1507.1.1.3/ R905.1.1.3) R905.1.1.3) Deck-Armor'"Premium Breathable Yes No No Yes Yes Yes No No Roof Deck Protection FeltBuster—Synthetic Roofing Felt Yes No No No No No No No Shingle-Mate°Roof Deck Yes No No No No No No No Protection Tiger Paw—Premium Roof Deck Yes No No Yes Yes Yes No No Protection VersaShield®Fire-Resistant Roof Yes No No No No No No No Deck Protection Yes Yes Ruberoidm Mop Granule No (Cap Sheet in (Cap Sheet in No No No No No 2-ply system) 2-ply system) See 5.6.1 Yes Yes Ruberoidm Mop Granule FR No (Cap Sheet in (Cap Sheet in No No No No No 2-ply system) 2-ply system) See 5.6.1 NEMO ETC,LLC Evaluation Report 01506.04.08-R22 Certificate of Authorization N32455 7TH EDITION(2020)FBC NON-HVHZ EVALUATION FL10626-1122 GAF Roof Underlayments Revision 22:06/09/2021 Page 4 of 9 NEMO etc. 5.6.1 Adhesive-set is limited to use of following underlayment/tile-adhesive combinations. FI1EIII Up f10N5 u n. L z z'" '* e.: k'-v r �" �' +�g ,c '^e' TMkk: ,rd•t'. + n" `� -,fi,K a0 55-3 y t r 22 s ti �' r Ad(f 11lB v3 iO�id pCtt$iBCt pQf tarull 3 Ruberoid°Mop Granule;Ruberoid®Mop Granule FR Dupont"Tile Bond"Roof Tile Adhesive" FL22525 5.7 Allowable Substrates: BE d � t•rid: i� x�P s r Y'fi's2` � 9�.'r{4 i Syti.:+� �" £Y i -«3;f'dfi .aE"•7X'.�,7 _,�'= 3a-S S,-•,< } �Ulttieriayment _� ";. ppl�s�tioK '^ ��'-`FnmeC u z i;:`�",..r. .,,�sE1�Cdt8S"`4 '`���i,� .E' GAF Extended Dry-In Membrane self-adhering None plywood Liberty-SBS Self-Adhering Base/Ply Sheet StormGuard'Film-Surfaced Leak Barrier self-adhering (Optional) plywood ASTM D41 Weather Watch®Mineral-Surfaced Leak Barrier Liberty'"SBS Self-Adhering Base/Ply Sheet StormGuard'Film-Surfaced Leak Barrier self-adhering None ASTM D226 felt,Type II Weather Watch'Mineral-Surfaced Leak Barrier Liberty'"^SBS Self-Adhering Base/Ply Sheet StormGuard'Film-Surfaced Leak'Barrier self-adhering ASTM D41 metal(flashing metal,valley metal, etc.) Weather Watch'Mineral-Surfaced Leak Barrier Ruberoid'Mop Granule hot asphalt ASTM D41 structural concrete Ruberoid'Mop Granule FR Ruberoid'Mop Granule hot asphalt None GAFGLAS'#80 Ultima'"" Base Sheet Ruberoid'Mop Granule FR or Ruberoid'20 Smooth 5.8 Attachment Limitations: 5.8.1 For use under mechanically attached NON-TILE prepared roof coverings,attachment shall be in accordance with the manufacturer's installation instructions,but—for mechanically attached underlayments or base sheets-not less than FBC 1507.1.1 or R905.1.1. 5.8.2 For use under tile roof systems, attachment shall be in accordance with the manufacturer's installation instructions, but—for mechanically attached base sheets-not less than: • FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1 (for Two-Ply Asphalt Applied Hot Mop Underlayment) or • -Section 5.8.3 herein (for other underlayment systems). 5.8.3 Wind Resistance for Underlayment Systems in Tile Roof Applications: The following wind uplift limitations apply to underlayment systems that are not prescriptive in the FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual,Sixth Edition. The Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads,and reflects the ultimate passing. pressure divided by 2(the 2 to 1 margin of safety per FBC 1504.9 has already been applied). 5.8.3.1 Direct-to-Deck: The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1A or the critical (highest) design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. 1 Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance. NEMO ETC,LLC Evaluation Report 01506.04.08-R22 Certificate ofAuthorization#32455 7-EDITION.(2020)FBC NON-HVHZ EVALUATION FL10626-1122 GAF Roof Underlayments Revision 22:06/09/2021 Page 5 of 9 ONEMOJetc. . ' . #1 Maximum Design Pressure=-442.5 psf. to satisfaction of Authority Having Deck: Min.2 500 psi structural concrete to meet project requirementsY g e Jurisdiction Base Sheet: GAFGLAS 475 Base Sheet,Tri-Ply 475 Base Sheet,GAFGLAS#80 Ultima Base Sheet,GAFGLAS Ply 4, Tri-Ply Ply 4 or GAFGLAS Flex Ply 6 applied in full mopping of ASTM D312,Type IV hot asphalt at 20 to 25 Ibs/square. Cap Sheet: Ruberoid® Mop Granule or Ruberoid° Mop Granule FR applied in full mopping of ASTM D312,Type IV hot asphalt at 20 to 25 Ibs/square, 5.8.3.2 Mechanically-Attached Base Sheet: The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI Florida High Wind Concrete and Clay Roof Tile installation Manual, Sixth Edition, Appendix A, Table 1A or the critical (highest) design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. Alternatively,the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1 design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. Elevated pressure zones shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (February 2020)for enhancements. #2 Maximum Design Pressure=-45 psf. Having 19 32-inch plywood to meet project requirements to satisfaction of Authority H g Deck: Min. / p y p 1 q Jurisdiction. Base Sheet: GAFGLAS' #80 Ultimar" Base Sheet or Ruberoid® 20 Smooth mechanically attached with 12 ga., min. 1.25-inch long ring shank nails through 32 ga., 1-5/8-inch diameter tin caps spaced 9-inch o.c. at the min. 4-inch wide side laps and 9-inch o.c. at two (2), equally spaced,staggered center rows in the field of the sheet. Cap Sheet: Ruberoid° Mop Granule or Ruberoid° Mop Granule FR applied in full mopping of ASTM D312,Type IV hot asphalt at 20 to 25 Ibs/square. #3 Maximum Design Pressure=-75 psf. Deck: Min. 19/32-inch plywood.to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: GAFGLAS' #80 Ultima'"^ Base Sheet or Ruberoid® 20 Smooth mechanically attached with 12 ga., min. 1.25-inch long ring shank nails through 32 ga., 1-5/8-inch diameter tin caps spaced 8-inch o.c. at the min.4-inch wide side laps and 8-inch o.c. at three(3),equally spaced,staggered center rows in the field of the sheet. Cap Sheet: Ruberoid' Mop Granule or Ruberoid"Mop Granule FR applied in full mopping of ASTM D312,Type IV hot asphalt at 20 to 25 Ibs/square. #4 Maximum Design Pressure=-97.5 psf. Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: GAFGLAS' #80 UltimaT' Base Sheet or Ruberoid' 20 Smooth mechanically attached with 11 ga., min. 1.25-inch long ring shank nails through 32 ga., 1-5/8-inch diameter tin caps spaced 4-inch o.c. at the min.2-inch wide side laps and 4-inch o.c. at four(4),equally spaced center rows in the field of the sheet. Cap Sheet: Ruberoid' Mop Granule or Ruberoid' Mop Granule FR applied in full mopping of ASTM D312,Type IV hot asphalt at 20 to 25 Ibs/square. NEMO ETC,LLC Evaluation Report 01506.04.08-1122 Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION FL10626-R22 GAF Roof Underlayments Revision 22:06/09/2021 Page 6 of 9 is ONEM01i 5.9 Exposure Limitations: Ly>wnrt TW •'�` ,?' u- � �U�Q.ri0. � t f i.� .�� �,� -s �� ,� �,�.r'-�sy.�� v k*, y,f �,�' � e '�t� �t � _'�r��dttOE�� �.-• +sue' � .�,�, "�� ��' '? � ,G s. �. ` • �'r'3 z-fan, �L �' JtWV � Deck-Armor'"Premium Breathable Roof Deck Protection,FeltBusterT"Synthetic Roofing Felt,Shingle-Mate® Roof Deck Protection,StormSafe'm Anchor Sheet,Tiger Paw'"Premium Roof Deck Protection,VersaShield°Fire-Resistant Roof Deck Mechanically attached 30 Protection,Liberty'"SBS Self-Adhering Base/Ply Sheet,StormGuard"Film-Surfaced Leak Barrier and WeatherWatch® Mineral-Surfaced Leak Barrier GAF Extended Dry-In Membrane Mechanically attached 180 Adhesive-set tile roof system 180 Ruberoid°Mop Granule and Ruberoid®Mop Granule FR Mechanically attached UNLIMITED 5.10 Tile Slippage Limitations: When loading roof tiles on the underlayment in direct-deck tile roof assemblies, the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. MY lillill2 1E ' ;4'Tt�S AP.Ir6EUMtThTIQ 4soUi 3TttECT)0 � ,,; �_.. Under ayme t` TiteProfife , �StagiKg Method NCa of 5tagmg 51ope ..a. ._. .a.... « .,. ..�. .4 . Flat Max.10-tile stack 4:12 Ruberoid®Mop Granule Flat Max.6-tile stack(4 over 2) 5:12 Lugged Max.10-tile stack 5:12 Ruberoid®Mop Granule FIR Fiat or Lugged Max.6-tile stack(4 over 2) 5:12 Lugged Max.10-tile stack 4:12 INSTALLATION:6. 6.1 GAF Roof Underlayments shall be installed in accordance with GAF published installation instructions subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application and prime the substrate(if applicable). � �" � "" �. , •- _ s � r 6:3 ' t!e 0 orTM Pre to Breatha'Lu R � Uec ti otecti nor ej<P w P em u R ec rc►tect. n ..:� ,. _ 6.3.1 Shall be installed in compliance with requirements for a synthetic underlayment in FBC 1507.1.1.1(2,Exception) or 1507.1.1.1(3,Exception)or FBC Residential R905.1.1.1(2,Exception)or R905.1.1.1(3,Exception)for the type of prepared roof covering to be installed,and the manufacturer's installation instructions. FBC requirements take precedence over the manufacturer's installation instructions. 6.4.1 Shall.be installed in compliance with requirements for a synthetic underlayment in FIX 1507.1.1.1(2,Exception), 1507.1.1.1(3, Exception) or 1507.1.1.1(5) or Fill Residential R905.1.1.1(2, Exception),R905.1.1.1(3, Exception) or R905.1.1.1(5) for the type of prepared roof covering to be installed, and the manufacturer's installation instructions. FBC requirements take precedence over the manufacturer's installation instructions. MEMO ETC,LLC Evaluation Report 01506.04.08-11122 Certificate of Authorization N324SS 7-EDITION(2020)FBC NON-HVHZ EVALUATION FL10626-11122 GAF Roof Underlayments Revision 22:06/09/2021 Page 7 of 9 NEMO etc. Sto "'Anchor Sheet• 6.5.1 StormSafe'"Anchor Sheet is limited to use as a mechanically attached base layer in 2-ply underlayment systems. 6.5.2 Shall be installed in compliance with requirements for a synthetic underlayment in FBC 1507.1.1.1(2,Exception) or 1507.1.1.1(3,Exception)or FBC Residential R905.1.1.1(2,Exception)or R905.1.1.1(3,Exception)for the type of prepared roof covering to be installed,and the manufacturer's installation instructions. FBC requirements take precedence over the manufacturer's installation instructions. 6.5.3 One the same day, install LibertyT" SBS Self-Adhering Base/Ply; StormGuard® Film-Surfaced Leak Barrier or WeatherWatch° Mineral-Surfaced Leak Barrier over the StormSafeW Anchor Sheet. fimgle-Mate• oof`Deek 6.6.1 Shall be installed in compliance with requirements for an approved mechanically attached underlayment (ASTM D226,Type II)in FBC Table 1507.1.1.1 or FBC Residential Table R905.1.1.1 for the type of prepared roof covering to be installed, and the manufacturer's installation instructions. FBC requirements take precedence over the manufacturer's installation instructions. —11' 6. 1lersa5hietd•Fire-Resi nt Roof De k Pr to ion. MUM 6.7;1 Shall be installed in compliance with requirements for an approved mechanically attached underlayment (ASTM D6757) in FBC Table 1507.1.1.1 or FBC Residential Table R905.1.1.1 for the type of prepared roof covering to be installed, and the manufacturer's installation instructions. FBC requirements take precedence over the manufacturer's installation instructions. 8 GAF Extended Dry-in embrane,Liberty Barrier o�Weather.; SB_SSe Mail m- ee M FSaracdekBarrier: y m 6.8.1 Shall be installed in compliance with requirements for an approved self-adhering underlayment(ASTM D1970)in FBC 1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering to be installed,and the manufacturer's installation instructions. 6.8.2 Back-nailing is required. Back-nailing shall consist of Approved cap nails spaced 18-inch o.c.,.encapsulated within min.4-inch side laps. 6.8.3 When installed over a mechanically attached, FBC Approved ASTM D226 Type II felt,the felt shall be fastened in accordance with FBC 1507.1.1 or R905.1.1. 6.8.4 GAF Extended Dry-In Membrane, LibertyTm SBS Self-Adhering Base/Ply Sheet,StormGuard® Film-Surfaced Leak Barrier or WeatherWatch® Mineral-Surfaced Leak Barrier may be installed as a secondary water barrier using minimum 4-inch wide rolls to seal plywood deck joints prior to installation of the primary underlayment system. 6:9 "Rube oid•.Mop�vra�nu e;Ruberoid•Mop Grano a ,R- 6.9.1 Shall be installed in compliance with requirements as an alternate to the "Hot Asphalt Applied Cap Sheet" in the "Two Ply System" in the FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth . Edition,and the manufacturer's installation instructions. 6.9.2 Refer to Section 5.8 herein for attachment limitations. 6.9.3 Refer to Table 4 for the staging limitations. NEMO ETC,LLC Evaluation Report 01506.04.08-R22 Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION FL10626-R22 GAF Roof Underlayments Revision 22:06/09/2021 Page 8 of 9 M- ---'-,NEM0 etc. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Contact the named QA entity for manufacturing facilities covered by F.A.C.Rule 61G20-3 QA requirements. Refer to Section 4 herein for products and production locations having met codified material standards. QUALITY9. UL, LLC.—QUA9625; (414)248-6409; karen.buchmann@ul.com -END OF EVALUATION REPORT- i NEMO ETC,LLC Evaluation Report 01506.04.08-R22 Certificate of Authorization#32455 7TH EDITION(2020)FBC NON-HVHZ EVALUATION F1.10626-1122 GAF Roof Underlayments Revision 22:06/09/2021 Page 9 of 9