HomeMy WebLinkAboutScanned DocumentsPlanning & Development Services = Building & Code Regulation Division 2300 Virginia Ave, Rm 201 • Fort Pierce, FL 34982 Phone:772-462-2165 Fax:772-462-6443 BLOWER DOOR TEST FORM House Infiltration Test Certification Prescriptive and Performance Method Date: �— z Z Permit ##: ;2 00 3 O D Contractor: P o /,-? -C Job Address: F-7 C �- Construction: ( A New Construction — Complete ( )Existing —After Addition House Infiltration Test Results SLC Climate Zone 2 c! CFM (50) = 3 YO Test Date: / ' Z Z Volume = _ 7 2 `1 % ACH (50) = CFM (50) x 60 / Volume = 3 o7r� Mechanical Ventilation required less than 3 ACM Passing results must be & ACH (50) or less ( ,}}Pass ( ) Fail FBC, Energy The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a blower door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(S) or (7), Florida Statutes or individuals licensed as set forth in Section 489,105 (3)(f), (g) or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at anytime after creation of all penetrations of the building thermal envelope. FBC, Residential Where the air infiltration rate of a dwelling unit is less than 3 air changes per hour when tested with a blower door at a pressure of 0.2 inch w. c. (50 Pa) in accordance with Section R402.4.1.2 of the Florida Building Code, Energy Conservation the dwelling unit shall be provided with whole -house mechanical ventilation in accordance with Section M1507.3. Testing Company Company Name: Pro -Duct Services Address: 1915 Rio Vista Dr. Fort Pierce,Fl. 34949 I hereby certify that the above House Infiltration results demonstrate compliance with FBC Energy Conservation requirements in accordance with Section R402.4.1.2 Climate Zone 2. Signature: Printed Name: Michael Faurot License/Certification #: 5059122 BUILDING PERFORMANCE INSTITUTE, INC. 107 Hermes Road, Suite 210 Malta. NY 12020 (877) 274-1274 www.bpi.org BPI Michael Faurot Ear 11)#- 5o5e122 CER't'! IED PP(,'Cr- _AL. m (StE REVERSE SIDE FOR DEgGNnom AND EXPIRATION DATES) CERTIFIED PROFESSIONAL DESIGNATION EXPIRATION DATE Infittration & Duct Lzakage 2i1612D23 BUILDING PERFORMANCE INSTITUTE, INC.