Loading...
HomeMy WebLinkAboutReport of Geotechnical Explorationh+ Florida's Leading Engineering Source Environmental •Geotechnical - Construction Materials Testing - Threshold and special Inspections • Plan Review. a Code Compliance July 16, 2020 Mr. Robert Holterman 10851 S Ocean Drive, Lot 89 Jensen Beach, Florida 34957 Subject: Report of Geotechnical Exploration Holterman Reilidence 10851 S Ocean Drive, Lot 89, Jensen Beach, Florida GFA Project No. 20-1127.00 Dear Mr. Holterman: GFA International, Inc. (GFA) is pleased to submit this report of geotechnical exploration for the above referenced project. Our services were performed in substantial accordance with our Proposal No. 20- 1127.00 dated June 19, 2020, planned in conjunction with and authorized by you. Field Exploration One (1) standard penetration test (SPT) boring, advanced to an approximate depth of 30 feet below the existing ground surface, was performed for this study. The boring was located by GFA personnel by estimating distances and offsets from the adjacent properties and other landmarks at the site. The approximate boring location is shown on the attached Test Location Plan. The Standard Penetration Tests (SPT) were performed in general accordance with ASTM D 1586, "Standard Test Method for Standard- Penetration Test (SPT) and -Split-Barrel Sampling of Soils." The SPT test procedure consists of driving a 1.4-inch I.D. split -barrel sampler into the soil profile using a 140-pound hammer falling 30 inches. The number of blows per foot, for the second and third 6-inch increment, is referred to as the N value. The N-value has been empirically correlated with various soil properties and provides an indication of soil strength. The upper 4 feet of the boring. were advanced using a hand auger due to potential utility line conflicts. This portion of the boring was performed in general accordance with ASTM D 1452, "Standard Practice for Soil Exploration and Sampling by Auger Borings." Hand Cone_Penetrometer (HCP) tests were conducted at one -fool: depth intervals in the auger boring. The HCP test, in conjunction with information about the soil type, is empirically correlated to the relative density of subsurface soils. Subsurface Conditions and Laboratory Testina The soil samples recovered from the boring were returned to our laboratory where they were visually classified by a geotechnical engineer in general accordance with the Unified Soil Classification System (ASTM D 2487). Selected samples were tested in the laboratory for moisture content (ASTM D 2216), fines content, or percent dry weight passing the U.S. No. 200 sieve (ASTM D 1140), and organic content (ASTM D 2974). The laboratory test results are summarized in the following table and are also contained on the boring log. 607 NW Commodity Cove • Port St Lucie, Florida 34986 • (772) 924-3575 • (772) 9243680 (fax) • www.teamgfa.com r.......-. Report of Geotechnical Exploration July 16, 2020 Holterman Residence -10851 S Ocean Drive, Jensen Beach, Florida Page 2 GFA Project No. 20-1127.00 The subsurface conditions encountered in the boring generally consisted of loose to medium dense fine sand (SP) and fine sand with silt (SP SM) to the boring termination depth. The results of the laboratory testing indicated that the soil layers between depths of approximately 4.5 and 8 feet had organic contents of 2.7 and 5.5 percent. Soils having similar organic contents are generally not considered problematic with regard to experiencing excessive settlement resulting from conventional single -story residential structure foundation loads. On the date of our fi Id a ploration (July 9, 2020), groundwater was encountered in the boring a tan approximate depth 4.3 eet below the existing ground surface. Note that the groundwater table will fluctuate seasonally epe ding upon local rainfall and other site specific and/or local influences, including tidal variations in the adjacent Jensen Beach to Jupiter Inlet Aquatic Preserve. Recommendations For conventional s Ilow, foundation systems, it is GFXs; opinion that a maximum allowable soil bearing pressure o 50Q psf is appropriate for the proposed structure subject to the limitations noted herein. We recommend t at the bottom of the footings bear at a depth of at least 12 inches below finish grade measured from the lowest adjacent grade. We also recommend a minimum footing width of 18 inches for spread footings.,and 16 inches for mondlithic footinas. ut not less tt,a R This report does not state or imply that the foundation soils at the gearing level will remain in the same condition in which they were found during .the subsurface exploration activities. Exposure to the environment may weaken the bearing soils if the foundation excavations remain open for an extended period or if the soils are exposed to rainfall. Therefore, it is recommended that the excavations for the wall and column footings be performed to final grade and foundation concrete be placed as soon as practicable to reduce the potential for deterioration of the bearing soils. GFA estimates that approximately 1 to 2 feet of fill will be required to raise the building pad to design grade. The 2 feet of soils below existing grade,. below. the bottom of all new footing excavations and slabs, and all fill material should be compacted to at least 95 percent of the modified Proctor (ASTM D 1557) maximum dry density prior to placement of concrete for the footings. During site preparation, foundations and the below grade remains of any structures that are within the footprint of the new residence should be removed. Similarly, utility or irrigation lines within the limits of the proposed construction should also be removed or properly abandoned so that they will not adversely impact new overlying structures. (, CA Report of Geotechnical Exploration July 16, 2020 Holterman Residence -10851 S Ocean Drive, Jensen Beach, Florida Page 3 GFA Project No. 20-1127.00 Closure Th' port has beer p�reR� ,oAr th clusive se of Mr. Robert Holterman for th sin fe- tory. res' _ 10851 S Ocean Dnve of 89, in Jensen Beach, Florida. Ob ces were >=ovi ed m actor ante wi gen y-a�C local geotechnical engineering practices; no other warranty is expressed or implied. This report does not reflect any variations in soil conditions which may exist away from the boring performed at the site. While the: boring is representative of the subsurface conditions at its location and vertical reach, local variations characteristic of the subsurface soils of the region are common. The delineation between soil types shown on the boring log is approximate and the descriptions represent our interpretation of the subsurface conditions at the designated boring location on the specific date drilled. GFA should be provided the opportunity to review the final foundation design plans and specifications to determine whether GFA's recommendations have been properly interpreted, communicated, and implemented. If GFA is not afforded the opportunity to participate in construction related aspects of foundation installation as recommended in this report or any report addendum, GFA cannot accept responsibility for the interpretation of our recommendations made in this report or in a report addendum for foundation performance. Any third -party reliance of this report or parts thereof is strictly prohibited without the expressed written consent of GFA International, Inc. The applicable SPT methodology (ASTM D 1586) and auger boring methodology (ASTM D 1452) used in performing our borings, and for determining penetration resistance, is specific to the sampling tools utilized and does not reflect the ease or difficulty to advance other tools or materials. We appreciate the opportunity to be of service to you during this phase of the project and look forward to a continued association. Please contact the undersigned if you have any questions or comments, or if we may further assist you as your plans proceed. Respectfully Submitted, ISFA INTERNATIONAL, INC. Florida Certificate of Authorization No. 4930 Digitally signed by John Kent John Ke n:tDate: 2020.07.16 08:15:54-04'00' John Kent, P.E. Senior Project Engineer Florida Registration No. 63218 This item tms been digitally signed and sealed by John Kent P.E. on the date adjacent to the seal. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Attachments: Test Location Plan SPT Boring Log Notes Related to Boring Records Distribution: Mr. Robert Holterman Erik Soderstrom, E.I. Geotechnical Department Manager a pdf (,CA ' _, NOTES RELATED TO BORING RECORDS AND GENERALIZED SUBSURFACE PROFILES 1. Groundwater levels (if encountered) were recorded either during or following the boring completion on the date indicated. Fluctuations In groundwater levels are common -.see the report text for a discussion. 2. The boring locations were identified in the field by estimated distances and offsets from existing reference marks and/or other site landmarks. 3. The completed boreholes were backfilied to adjacent site grade using drilling spoils and patched with asphalt cold mix in pavement areas. 4. The Log of Boring records represent our interpretation of soil conditions based on visual classification of the soil samples recovered from the borings. 5. The Log of Boring records are subject to the limitations, conclusions, and recommendations presented in the report text 6. The Standard Penetration Test (SPT) N values contained on the Log of Boring records refer to the total blow counts of a 140-pound drop hammer falling 30 inches required to drive a split -barrel sampler a total distance of 12 inches Into soil strata at specific depth intervals. 7. The Hand Cone Penetrometer (HCP) values contained on Log of Boring records and the Cone Penetration Test (CPT) values contained on the Cone Penetration Sounding logs refer to the cone tip resistance recorded when pushing the cone tip into the soil strata at specific depth intervals. 8. The soil and/or rock strata interfaces shown on the Log -of Boring records are approximate and may vary from those shown on the logs. The soil and/or rock descriptions shown an the Log of Boring records refer to conditions at the specific location tested. Soilfrock conditions may vary between test locations. 9. Relative density for coarse -grained sods (sands/gravels) and consistency forfine-grained soils (silts/clays) are described as follows: Coarse Grained Soils (Sands and Gravels) Fme Grained Soils (Sift and Clays) SPT N-Value HCP Value (kg/cm2) CPT Value (tsf) Relative Density SPT N Value HCP Value (kg/cm2) CPT Value Consistency 0-4 0-16 0-20 Very Loose 0-2 a 20 0-3 Very Soft 5-10 17-36 21-40 Loose 3-4 21-35 4-6 Soft 1.1-30 37-116 41-120 Med. Dense 5-8 >35 7-12 Firm 31-50 117-196 1 121200 1 Dense 9-15 1 1 13-25 Stiff >50 > 196 >200 Very Dense 16-30 26-50 Very Stiff >30 >50 Hard 10. Grain size descriptions are as follows: Description Particle Sae Limits Boulder Greater the 12 inches Cobble 3 to 12 inches Coarse Gravel 314 to 3 inches Fine Gravel No. 4 sieve to 3/4 inch Coarse Sand No.10 to No. 4 sieve Medium Sand No. 40 to No.10 sieve Fine Sand No. 200 to No. 40 sieve Fines Silt/Cla Smaller than No. 200 sieve 11. Definitions for modifiers used in soil/rock descriptions: Proportion Modifier Approximate Root Diameter Modifier <5% Trace Less than Ile Fine roots 5% to 12% Little 1/31" to Small roots 12% to 30% Some '/a to 1" Medium roots 30% to 50% And Greater than 1" La!Re roots Organic Soils: Soils containing vegetative tissue in various stages of decomposition having a fibrous to amorphous texture. Usually having a dark brown to black color and an organic odor. Organic Content Modifiers: <25°%: Slightly to Hi hl O anic; 25% to 750/6: Muck; >75%: Peat 19 607 NInternational,mods y C LOG OF BORING B-1 607 NW Commodity Cove Port Saint Lucie, Florida 34986 PAGE 1 OF 2 (772) 924-3575 44vw por CLIENT Mr. Robert Holterman PROJECT NAME Holtennan Residence PROJECT NUMBER 20-1127.00 PROJECT LOCATION 10851 S Ocean Drive Lot 89 Jensen Beach Florida DRILLING CONTRACTOR GFA Intemational Inc. HOLE DEPTH 30 ft HOLE DIAMETER 3 in DRILLER JB/SP DATE STARTED 7/9/20 COMPLETED 7/9120 DRILL RIG Simco GROUND WATER LEVEL --SAT TIME OF DRILLING 4.30 ft METHOD SPT LAiiTUDE LONgTUDE NOTE: HAMMERTYPE W WD: m 'u Wiiii _ c7 11�21 �O W faIL Z WO Z 'a 1 0 vi 0 FFJ O� N 2.5 0 z 2 w U z W 0 W U O 5. 3 z w 0 4 = 0 7.5 0 N a 0 0 ti 5 U w O a 10. N N O A • (W� a 12. n f- Q LL � 6 so so _ so .i 8D .I 3 3 1 4 2 a 5 3 9 12 21 17 6 5 10 MATERIAL DESCRIPTION Light brown fine sand, trace rock (SP) Brown fine sand, trace shell (SP) Dark brown line sand with silt, few organics (SP-SM) Dark gray fine sand, little silt, trace organics (SP) Gray fine sand, trace shell (SP) Wot U z_w Qw 92w MO LLO (9 0O U U U 52.8 5.1 5.5 28.1 4.1 2.7 i r ii x GFA International, Inc. LOG OF BORING B-1 607 NWW Commodity Cove Port Saint Lucie, Florida M86 PAGE 2 OF 2 (772)924-3575 Ndi1®� CLIENT Mr. Robert Holterman PROJECT NAME Holterman Residence PROJECT NUMBER 20-1127.00 PROJECT LOCATION 10851 S Ocean Drive Lot 89, Jensen Beach Florida = J JW 'S F � U = a W F- fA F- Uo F- w v g 2 2> > 0 MATERIAL DESCRIPTION co w z w Q w �F- N NZ mV Z 0 F- rF- OU 20 U 17. Gray fine sand, trace shell (SP) (continued) Gray fine sand, trace silt and shell (SP) 16 7 10 7 17 23.5 Light gray fine sand with silk little shell and cemented sand (SP-SM) 14 8 7 s 13 20 9 io 24 �.0 Bottom of borehole at 30.0 feet Test Location Plan PROJECT NO: 20-1127.00 Le end, Holterman Residence 10851 S Ocean Drive, Lot 89, Jensen Beach, Florida DRAFTED BY- JR REVIEWED BY: JK DATE: 7115/2020 P7 Approximate 30' Standard Penetration Test Boring Location N