HomeMy WebLinkAboutFLOOR PLAN6
0 0
FINISH BACK
OF DRYWALL
DRYER VENT 21„
RECESS
i
DRYS VENT
RECE S
SIDE VIEW FRONT VIEW
` /�
1l 1 �l �l I �s T I L
VENT
P.T. 2X6 BUCK ATTACHED WITH
3/8"x3°SLEEVE ANCHOR BOLTS (1-1/2"EM5ED) ON 11" CENTERS
(20M PSI MIN. CONCRETE). WASHERS INCLUDED WITH SLEEVE ANCHORS.
OR
1/4"x3" TAPCON SCREWS CI-I/2" EMBED) ON 14" CENTERS
(2000 P51 MR CaMTE) OR W CENTERS (C-90 6LOCIU.1- MR OD. W45 M RE(�UIRM WITH TAFCaB.
ANCHORS MAY BE COUNTERSUNK TAL NOT ONOREQUIRED) TO PROVIDE A
FLUSH MOUNTING SURFACE. HORIZONTAL JAMBS p0 NOT TRANSFER LOAD.
❑ ❑
O.H. DOOR
0 0 0 1-"5 VERTICAL (TYP.)
2'-0" O.H. DOOR
1 DTL e 0-H, G,4R,4GE DOOR E3UC<
e. o•e. a
e,.° e,.° ; INSULATION
8" CBS WALL ° °
° ' ° ° ' °
P.T. BUCK ATTACHED °• ° ° °• °° ° 1/2" DRYWALL
° °
TO GBS WALL W/ 1"X4" PT. WRAP
1 I/2" CASE HARDEN W
NAIL, 3" FROM EDGE !�
AND 12" O.G. FIELD 3/16"x 1 1/4" EMBED TAPCONS
SPACING,
MAX. 1/4" SHIM PER OPENING SCHEDULE
(NO WOOD)
WINDOW
NOTE: PLYWOOD FILLER
MAY BE USED TO PAD •c .° •c .°d•c .°
OUT OPENING USING SAME ° ' ° ' °
o, a o, 'a,
NAILING AND INCREASING o °°°
TAPCON LENGTH THE
THICKNESS OF THE PLYWOOD
FILLER N
NOTE:
PRIOR TO BUCK INSTALLATION
APPLY A WATER RE51TANT COATING
(PER FBG RESIDENTIAL R-�03.4)
2 �'F. LUINDOLU 5UC�< DETAIL=
I. 2x P.T. ON SIDES OF MASONRY OPENING
2. FASTEN SIDES THRU JAMB E 2x WITH
1/4" x 4 1/2" TAPCONS, 6" FROM THE TOP
a BOTTOM 4 16" O.C. BETWEEN. A SINGLE
ROW OF FASTENERS IS ALL THAT IS
REQUIRED.
3. FILLED CELLS ON BOTH SIDES OF
OPENINGS ONLY ONE SIDE REQUIRES
1 S VERT.
6-8" ii
Z
Q
16 MAX.
0
0
o
16" MAX.
O
if
16" MAX. >
lX
6 -8
REVISIONS
DATE
FIELD
1 REV
12-23-21
5/8" DRYWALL
ATTACHED TO TRUSS WITH
1 1/4" % SCREWS, 12" O.G. FIELD
8" O.C. BUTT JOINTS
1/2" DRYWALL BOTH SIDES
WALL ATTACHED WITH
I I/4" +'6 SCREWS, 12" O.C. FIELD
8" O.G. BUTT JOINTS
WOOD BASE d TRIM
CONT. 25 GAUGE METAL TRACK
TOP AND BOTTOM O.C.1/2"
(I) 10 SMS a 24 .C25
25 GAUC:E CHANNEL SHAPED METAL
SCUDS 24" O.G.
BOTTOM TRACK ATTACHED TO SLAB WITH
HILT[ PINS .145" DIA. X I" LONG
Cleo" O.G.
FINISHED FLOOR
1/2" or 5/8" DRYWALL
ATTACHED TO TRUSS WITH CONT. 25 GAUGE METAL TRACK
I I/4" •6 SCREWS, 12" O.C. FIELD TOP AND BOttOM W/
8" O.G. BUTT JOINTS �
CIJ 10 SMS g 24' O.G.
DRYWALL BOTH SIDES GAUGE CHANNEL SHAPED METAL
WALL ATTACHED WITH
1 1/4" % SCREWS 12" O.G. FIELD STUDS 24" O.G.
8' O.G. $UTT JOINTS
GARAGE SIDE LIVING: SPACE SIDE
R-13 BAtt INSULATION BOTTOM TRACK ATTACHED TO SLAB WITH
HILTI PINS .145" DIA. X I" LONG
616" O.G.
FINISHED FLOOR
_
O
aJ O
C
�
M O
N N
�. N f V
(V
_ M
4- •- N O
J C: 4 � (4
0NO rj
„
„ "&,-,,
. ' ..,
: �� �� =
2 h a o 02�
- �-
.o w
-0 o i a oz=
......
EM
NOTE:
PRIOR TO BUCK INSTALLATION
APPLY A WATER RESITANT COATING
(PER FBC RESIDENTIAL R-103.4)
� EXTERIOR DOOR 5UCf< DETAIL
RA NON=SEARING WALL DETAIL
N.T.S.
3 TTP. NON=SEARING WALL DETAIL
'a 3 SCALP: N.T.5.
'43 SCALE: N.T.S.
43 SCALP: N.T.S.
SCALE: N.T.5.
SCALE: N.T.S.
40'-0"
30'-0" I-411
21'-1" 8'-5" _ 91-4
e N fRA L I C T E 5
U>
VH
H
�
� w
W a
w
A
Z �
O1 J W
W �
� 0 � o Z U
V O� '(�' W �
� U N 4 H
W W
0 � U
(V x
00 a a 04 U
8"
0
- -
I
I
I
CLG. 1
1
1
TILE TO
CEILING
HB ul
-
0
-'
8„
METER
8
0 G�)lci)(i)
_ _ FI _
T
UJ.I.0 M. i�R®®1f
8-m"c. LG. I
M
I 1'-I" 1 4" r- 15'-3"
1 -
m
-DRYWALL HEADER
5m68 EiF 1 1 "`
CLOSET oo
- - - - - - " „ „
1 2 4 2 2 1 0
e N
I Pa�1TRY
20
5m686F 68EF m
, m
12'-I" '20"4" �; 2'tm" `^ 4' 8" 3 - " 3'-0"
0
- - - -
PORCH
O V-0" STUCCO
I, ,l Im-m"
6
Ec Ess
�r
_
1
6068 SCGD
- O O -
- -
DRYWALL HEADER
DINING
YAULTEDcLG.
I0'-9"
-
tr
-
e
O1. THE CONTi�ACT01� &PALL VEi;11= ' ALL EXISTING CONDITIONS WHICH WILL EFFECT
WORK. IF
THE INSTALLATION OF ALL NEW WOIF DISCREf=ANCIES ARE DISCOVERED,
DESIGNER 1 IUST 5E NOTIFIED E3EFORE PROCEEDING WITH ANT 1 IODIFICATION TO
THE �4PPROVED DOCUI-IENTS.
02. ALL CONSTRUCTION 5HALL CO1"IPLT WITH ALL STATE COUNTT AND LOCAL CODES
AND APPL IC,45LE AMENDMENT& LATEST EDITION
03, THE CONTRACTOR IS RESPONSI5LE 1-0R THE ADEQUATE 5FACING OF ALL STRUCTURZ4L
AND NONSTRUCTUR�4L COMPONENTS DURING CONSTRUCTION.
04, DO NOT SCALE Df;PAWING5. WRITTEN DIMENSIONS TA<E PRECEDENCE OVER WHAT
DRAWINGS 11'f,4�1' SCALE OR IF WRITTEN DIMENSIONS DO NOT EXIST WHICH �4RE
�
NECESSj4RT FOR CONSTRUCTION, THE CONTRACTOR MUST CONTACT THE DESIGNER
TO 057A IN SAIE.
05- INFORMATION FOR THE 5,45IC L,4TOUT OF THIS DRAWING WAS 5ASED ON EXISTING OR
FIELD DIMENSIONS ( F. D. ). CONTR�4CT0R MUST VERf1-T IN 1-fELD V. I. 1-.�
ACTUAL CONDITIONS AS DISCOVERED ,AND 05SERVED ,AND NOTIFT DESIGNER OF
ANT D ISCREfi ANCIES.
0(o. THE CONTRACTOR / OWNER � I1- OWNER 5UILDER �, IS SOLELT RESPONSI5LE* FOR
THE MEANS AND METHODS OF CONSTRUCTION, AND THE 5AFETT OF CONSTRUCTION
WORKERS.
0�. ,ALL LUORI< SHALL 5E 1=REI=ORMED 5T CONTR,4CTOR6 POSSESSING VLID CERTIFICATES
OF COMPETENCT AND OCCU1=ATIONAL LICENSES, RECOGNIZED AND ACCEPTED 5T
THE LOCAL GOVERNMENT HAVING JURISDICTION, OR 5T OWNER-
08. TO THE 5E5T OF MT <NOWLEDG-�E, THE 1=LAN5 AND SRECIFICATIONS SUE5I1ITTED
HEREWITH COMPLT WITH ,ALL EXISTING IN7ERRRET,47ION6 ,AND PROVISIONS OF THE
APPL ICA5LE 51JILDING CODES AT THE TIME OF THE PLANS RRERAf;RATION- NO
UJARRjANTT EITHER EXPRESSED OR IMPLIED 15 HEREWITH GIVEN.
Oe- CONTR�4CT0R / OWNER SHALL VERII=T ,ALL DIMENSIONS RELATED TO ,ANT 1=,4RT
OF CONSTRUCTION PRIOR TO 5EGINNING WOR< OR ORDERING F,45RICATED 1"IATERIALS
REQUIRED 1-0R CONSTRUCTION.
10. ENGINEER' S SE,4L fLu
S 1-0R ,4PPROV,4L 01- STRUCTURAL DESIGN ONLT.
11. ,ALL GLASS IN HAZARDOUS LOCATIONS TO COMPLT WITH R308.4
THM 200. (302.9.1)
12. W,4LL ,4ND CEILING FINI5HE5 5I�,4LL H,4VE A FL,4MC E=5PRE,4D CL,455IFI,4TION OF NOT GRE,4TER R
13. W,4LL j4ND CEILING FINI5HE5 5H,4LL H,4VE ,4 5110<E=DEVELOPED INDEX OF NOT GRE,4TER TH,4N 450. (R302.9.2)
14. ,4LL TERiYIITE PROTECTION SHOULD COI IPLT WITH R310 , PROP05ED HOUSE IN VERY 1HE,4VT TERi IITE ,4RE,4.
1E5- ALL LUM5ER USED SHOULD HAVE QUAL ITT Mj4R<S PER R311.2
16. TILE TO BE IN5T,4LLE1) OVER FIBER=CEI IENT OR GL,455 1„Ij4T GTP51J1l 5,4C1<ER5. (RT02.4.1 ,AND R102.4.2.).
IN SHOWER SURROUND AREAS.
11. WEAT14ERING IS NEGL IG ,45LE.
18. GTPSUM 1�0,4RD COMPLIES WITH 1-3C 702.3
SHOWER
�,
I" 2" T
M. BATH
LA 8'-0" C.L.G.
LAv
2868
1
I
I
O I
2068 BF_
uN>LN
I >„
O
O
_
4
>
�C
�
CID
U
01
cs
0
O
=
Z
40 mo
CD €Z N
Na
� I
AV LINEN
�� 1668BF I KID
8 m"� REF MAUL
�.4TH 2 I
8'-0" CLCs.
2868 @ -
2868
20"x20' a
wA 1 M
3'-4" 2'-10" 2,_
cLG.
10'-9" 5068 BF " 2'�0" 6'-4"
m
�a
=
-
c I
0 i
_
COUNTER
-
AT 36" AFF
1
Typ
T
LIFT
TA 1
EG�ss
AC
COMP.
O
@
'n
uB
We
'n
H N
DLG.
11 DRYWALL
3
R 14T ®®i„i
FADER VAULTED CLCx. �'
o
�r
8'-0'
E��55
8"
HB
o
1LU
� �
0;� _
�
c�
1LJLaL �
�
CS
Tl
4"
°
v
I6„
��4UND-RY
I PRYER
IVTR)
200 AMP PANEL 2868 SOLID
_ CORE (20 MIN-
22" X- 54" FIRE RATED)
ATTIC ACCESS (sELF-cLosING)
L R-13 INSULATION
BEARING WALL W/ -
R-13 INSULATION
20'-0" 4"
$ m CLG
1
3
O (TYP.) _\
51_111 A'T'_21, "-,0"
I � V
°
-
5T. LUCK COUNTT 5UILDING DEPARTMENT PRODUCT APPROVAL REVIEU AFFIDAVIT
- -
•�
61-0"
FOYER
VAULTED CLG.
T
5 -�" 4" 12 -4"
/ -` =
2
- 3
NTRY
O _8 m cLG O O ` O
WH
i[l m
BOLLARD
PAINTED FINISH,g,R,g,
ON BLOCK WALL(TYP.)
IN GARAGE
F-
e
4068 BF
OPENING SCHEDULE: SWING DOORS, OVERHEAD DOORS, SLIDING DOORS, FIXED GLASS, WINDOWS, & SKYLIGHTS:
°
OPENING
ID
PRODUCT
MODEL
SIZE
MANUFACTURER
GLASS
DESCRIPTION
ATTACHMENT METHOD
TYPE, SIZE, SPACING, &EMBEDMENT
PRODUCT APPROVAL
NUMBER
U-FACTOR
SHGC
BUILDING DESIGN
PRESSURE
PRODUCT DESIGN
PRESSURE
1
EXTERIOR DOOR
METAL
192" X 84"
CLOPAY
N/A
SEE DETAIL 1 A3
FL 16546.5
n/a
n/a
+31.86/ -38.74
+36.0 / -42.0
°
Q
2
EXTERIOR DOOR
OPAQUE FIBERGLASS
36" X 80"
THERMATRU
N/A
1/4" x 3 1/4 " TAPCONS 6" FROM EDGES, 12" O.0 FIELD
FL 20468.1
.14
.01
+35.96 -39.16
+50.0 -50.0
3
25 SINGLE HUNG
VINYL SH-610 SERIES
38" X 63"
CUSTOM WINDOW SYSTEMS
ANNEALED
3/16" TAPCONS, 1 1/4 " EMBED.,6" MAX FROM EDGE, 14 1/2" MAX O.C. FIELD
FL 17234.1
.29
.26
+31.52/-40.81
+50.0 -50.0
4
VINYL SH-610 SERIES
38" X B3"
CUSTOM WINDOW SYSTEMS
ANNEALED
3/16" TAPCONS, 1 1/4 " EMBED.,6" MAX FROM EDGE, 14 1/2" MAX O.C. FIELD
FL 17234.1
.29
.29
+37.52 -40.81
+50.0 -50.0
°
EXTERORLSGDNDOOR
ALUM. 9000 SERIES
12 X 80
CUSTOM WINDOW SYSTEMS
TEMP.
3 i6 TAPCONS, 1 1 4 EMBED., 6 MAX FROM EDGE, 21 MAX O.C. FIELD
FL 11908.1
.61
.33
+35.96 -39.16
+50.0 -50.0
6
25 SINGLE HUNG
VINYL SH-610 SERIES
38" X 63
CUSTOM WINDOW SYSTEMS
ANNEALED
3 i6" TAPCONS, 1 1/4 " EMBED.,6" MAX FROM EDGE, 14 1/2' MAX O.C. FIELD
/ / /„
FL 17234.1
29
29
+37.52 -40.81
/
+50.0 -50.0
7
FIXED GLASS WINDOW
VINYL PW-615 SERIES
" „
12 x 16
CUSTOM WINDOW SYSTEMS
ANNEALED
„ „ „
3/16 TAPCONS, 1 1/4 EMBED,,6 MAX FROM EDGE, 9 1/2 MAX O.C. FIELD
FL 17354.1
•28
.32
+31.52 -40.81
+50.0 -50.0
8
25 SINGLE HUNG
VINYL SH-610 SERIES
38" X 63"
CUSTOM WINDOW SYSTEMS
ANNEALED
3/16" TAPCONS, 1 1/4 " EMBED,,6" MAX FROM EDGE, 14 1/2" MAX O.C. FIELD
FL 17234.1
.29
.29
+37.52/-40.81
+50.0 -50.0
9
25 SINGLE HUNG
VINYL SH-610 SERIES
38" X 63"
CUSTOM WINDOW SYSTEMS
ANNEALED
3/16" TAPCONS, 1 1/4 " EMBED.,6" MAX FROM EDGE, 14 1/2" MAX O.C. FIELD
FL 17234.1
.29
1 .29
+37.52/-40.81
+50.0 -50.0
PRODUCT
MODEL
MANUFACTURER
ATTACHMENT METHOD
TYPE SIZE SPACING EMBEDMENT & STIFFENER ETC.
PRODUCT APPROVAL 1
NUMBER
BUILDING DESIGN
PRESSURE
PRODUCT DESIGN
PRESSURE
O
Q
O
N
_
3
(EGRESS)
e
ROOF UNDERLAYMENT
SOPREMA
SOPREMA, INC
PEEL AND STICK
FL 2569.1
ROOF
SHINGLES
IKO INDUSTRIES
FIBERGLASS REINFORCED SHINGLE, 6 FASTENERS PER CODE
FL 30310.1
SIDING
STUCCO
RINKER
(3) LAYERS STUCCO APPLIED TO MASONRY WALL
HUDSON-4 -LH
SOFFIT
STUCCO
RINKER
(3) LAYERS STUCCO APPLIED TO HIGH RIBBED METAL LATH NAILED TO TRUSS TAILS PER FBC R703.6.1, 1 3/4" FASTENER 6" O.C.
PER ASTM C1063 SEC. 7.10.2.3
Date: 01-30-21
HURRICANE PANELS
METAL
HURRICANE
STORM PANEL
MFG., INC.
ELCO PANELMATE PLUS 1/4" DIA. SCREW, 1 3/4" MIN EMBED. , MIN. 12 " O.C.
FL16293-R2
(SEE OPENING
PRESSURES ABV.)
SEE OPENING
PRESSURES ABV.)
Scale: AS SHOWN
O
00
00
16'-0"
21'-4"
40'-m"
LUALL LEGEND
AREA CALCULAT ION15
Drawn: TS
4'-I0" 13'-10"
S" CONC. BLOCK S'-1" AFf
4" WOOD BEARING PARTITION W1 R-13 INSULATION
4" INT. PARTITION W1 R-13 INSULATION
4" OR 6" INT. PARTITION FULL HEIGHT
LIVING 1033 SF
GARAGE 435 SF
PORCH 13C SF
ENTRY 24 5F
L O O R FLAN
5C,4LE: 1/4'' = 1' -011
TOTAL 2420 5F