Loading...
HomeMy WebLinkAboutFLOOR PLAN6 0 0 FINISH BACK OF DRYWALL DRYER VENT 21„ RECESS i DRYS VENT RECE S SIDE VIEW FRONT VIEW ` /� 1l 1 �l �l I �s T I L VENT P.T. 2X6 BUCK ATTACHED WITH 3/8"x3°SLEEVE ANCHOR BOLTS (1-1/2"EM5ED) ON 11" CENTERS (20M PSI MIN. CONCRETE). WASHERS INCLUDED WITH SLEEVE ANCHORS. OR 1/4"x3" TAPCON SCREWS CI-I/2" EMBED) ON 14" CENTERS (2000 P51 MR CaMTE) OR W CENTERS (C-90 6LOCIU.1- MR OD. W45 M RE(�UIRM WITH TAFCaB. ANCHORS MAY BE COUNTERSUNK TAL NOT ONOREQUIRED) TO PROVIDE A FLUSH MOUNTING SURFACE. HORIZONTAL JAMBS p0 NOT TRANSFER LOAD. ❑ ❑ O.H. DOOR 0 0 0 1-"5 VERTICAL (TYP.) 2'-0" O.H. DOOR 1 DTL e 0-H, G,4R,4GE DOOR E3UC< e. o•e. a e,.° e,.° ; INSULATION 8" CBS WALL ° ° ° ' ° ° ' ° P.T. BUCK ATTACHED °• ° ° °• °° ° 1/2" DRYWALL ° ° TO GBS WALL W/ 1"X4" PT. WRAP 1 I/2" CASE HARDEN W NAIL, 3" FROM EDGE !� AND 12" O.G. FIELD 3/16"x 1 1/4" EMBED TAPCONS SPACING, MAX. 1/4" SHIM PER OPENING SCHEDULE (NO WOOD) WINDOW NOTE: PLYWOOD FILLER MAY BE USED TO PAD •c .° •c .°d•c .° OUT OPENING USING SAME ° ' ° ' ° o, a o, 'a, NAILING AND INCREASING o °°° TAPCON LENGTH THE THICKNESS OF THE PLYWOOD FILLER N NOTE: PRIOR TO BUCK INSTALLATION APPLY A WATER RE51TANT COATING (PER FBG RESIDENTIAL R-�03.4) 2 �'F. LUINDOLU 5UC�< DETAIL= I. 2x P.T. ON SIDES OF MASONRY OPENING 2. FASTEN SIDES THRU JAMB E 2x WITH 1/4" x 4 1/2" TAPCONS, 6" FROM THE TOP a BOTTOM 4 16" O.C. BETWEEN. A SINGLE ROW OF FASTENERS IS ALL THAT IS REQUIRED. 3. FILLED CELLS ON BOTH SIDES OF OPENINGS ONLY ONE SIDE REQUIRES 1 S VERT. 6-8" ii Z Q 16 MAX. 0 0 o 16" MAX. O if 16" MAX. > lX 6 -8 REVISIONS DATE FIELD 1 REV 12-23-21 5/8" DRYWALL ATTACHED TO TRUSS WITH 1 1/4" % SCREWS, 12" O.G. FIELD 8" O.C. BUTT JOINTS 1/2" DRYWALL BOTH SIDES WALL ATTACHED WITH I I/4" +'6 SCREWS, 12" O.C. FIELD 8" O.G. BUTT JOINTS WOOD BASE d TRIM CONT. 25 GAUGE METAL TRACK TOP AND BOTTOM O.C.1/2" (I) 10 SMS a 24 .C25 25 GAUC:E CHANNEL SHAPED METAL SCUDS 24" O.G. BOTTOM TRACK ATTACHED TO SLAB WITH HILT[ PINS .145" DIA. X I" LONG Cleo" O.G. FINISHED FLOOR 1/2" or 5/8" DRYWALL ATTACHED TO TRUSS WITH CONT. 25 GAUGE METAL TRACK I I/4" •6 SCREWS, 12" O.C. FIELD TOP AND BOttOM W/ 8" O.G. BUTT JOINTS � CIJ 10 SMS g 24' O.G. DRYWALL BOTH SIDES GAUGE CHANNEL SHAPED METAL WALL ATTACHED WITH 1 1/4" % SCREWS 12" O.G. FIELD STUDS 24" O.G. 8' O.G. $UTT JOINTS GARAGE SIDE LIVING: SPACE SIDE R-13 BAtt INSULATION BOTTOM TRACK ATTACHED TO SLAB WITH HILTI PINS .145" DIA. X I" LONG 616" O.G. FINISHED FLOOR _ O aJ O C � M O N N �. N f V (V _ M 4- •- N O J C: 4 � (4 0NO rj „ „ "&,-,, . ' .., : �� �� = 2 h a o 02� - �- .o w -0 o i a oz= ...... EM NOTE: PRIOR TO BUCK INSTALLATION APPLY A WATER RESITANT COATING (PER FBC RESIDENTIAL R-103.4) � EXTERIOR DOOR 5UCf< DETAIL RA NON=SEARING WALL DETAIL N.T.S. 3 TTP. NON=SEARING WALL DETAIL 'a 3 SCALP: N.T.5. '43 SCALE: N.T.S. 43 SCALP: N.T.S. SCALE: N.T.5. SCALE: N.T.S. 40'-0" 30'-0" I-411 21'-1" 8'-5" _ 91-4 e N fRA L I C T E 5 U> VH H � � w W a w A Z � O1 J W W � � 0 � o Z U V O� '(�' W � � U N 4 H W W 0 � U (V x 00 a a 04 U 8" 0 - - I I I CLG. 1 1 1 TILE TO CEILING HB ul - 0 -' 8„ METER 8 0 G�)lci)(i) _ _ FI _ T UJ.I.0 M. i�R®®1f 8-m"c. LG. I M I 1'-I" 1 4" r- 15'-3" 1 - m -DRYWALL HEADER 5m68 EiF 1 1 "` CLOSET oo - - - - - - " „ „ 1 2 4 2 2 1 0 e N I Pa�1TRY 20 5m686F 68EF m , m 12'-I" '20"4" �; 2'tm" `^ 4' 8" 3 - " 3'-0" 0 - - - - PORCH O V-0" STUCCO I, ,l Im-m" 6 Ec Ess �r _ 1 6068 SCGD - O O - - - DRYWALL HEADER DINING YAULTEDcLG. I0'-9" - tr - e O1. THE CONTi�ACT01� &PALL VEi;11= ' ALL EXISTING CONDITIONS WHICH WILL EFFECT WORK. IF THE INSTALLATION OF ALL NEW WOIF DISCREf=ANCIES ARE DISCOVERED, DESIGNER 1 IUST 5E NOTIFIED E3EFORE PROCEEDING WITH ANT 1 IODIFICATION TO THE �4PPROVED DOCUI-IENTS. 02. ALL CONSTRUCTION 5HALL CO1"IPLT WITH ALL STATE COUNTT AND LOCAL CODES AND APPL IC,45LE AMENDMENT& LATEST EDITION 03, THE CONTRACTOR IS RESPONSI5LE 1-0R THE ADEQUATE 5FACING OF ALL STRUCTURZ4L AND NONSTRUCTUR�4L COMPONENTS DURING CONSTRUCTION. 04, DO NOT SCALE Df;PAWING5. WRITTEN DIMENSIONS TA<E PRECEDENCE OVER WHAT DRAWINGS 11'f,4�1' SCALE OR IF WRITTEN DIMENSIONS DO NOT EXIST WHICH �4RE � NECESSj4RT FOR CONSTRUCTION, THE CONTRACTOR MUST CONTACT THE DESIGNER TO 057A IN SAIE. 05- INFORMATION FOR THE 5,45IC L,4TOUT OF THIS DRAWING WAS 5ASED ON EXISTING OR FIELD DIMENSIONS ( F. D. ). CONTR�4CT0R MUST VERf1-T IN 1-fELD V. I. 1-.� ACTUAL CONDITIONS AS DISCOVERED ,AND 05SERVED ,AND NOTIFT DESIGNER OF ANT D ISCREfi ANCIES. 0(o. THE CONTRACTOR / OWNER � I1- OWNER 5UILDER �, IS SOLELT RESPONSI5LE* FOR THE MEANS AND METHODS OF CONSTRUCTION, AND THE 5AFETT OF CONSTRUCTION WORKERS. 0�. ,ALL LUORI< SHALL 5E 1=REI=ORMED 5T CONTR,4CTOR6 POSSESSING VLID CERTIFICATES OF COMPETENCT AND OCCU1=ATIONAL LICENSES, RECOGNIZED AND ACCEPTED 5T THE LOCAL GOVERNMENT HAVING JURISDICTION, OR 5T OWNER- 08. TO THE 5E5T OF MT <NOWLEDG-�E, THE 1=LAN5 AND SRECIFICATIONS SUE5I1ITTED HEREWITH COMPLT WITH ,ALL EXISTING IN7ERRRET,47ION6 ,AND PROVISIONS OF THE APPL ICA5LE 51JILDING CODES AT THE TIME OF THE PLANS RRERAf;RATION- NO UJARRjANTT EITHER EXPRESSED OR IMPLIED 15 HEREWITH GIVEN. Oe- CONTR�4CT0R / OWNER SHALL VERII=T ,ALL DIMENSIONS RELATED TO ,ANT 1=,4RT OF CONSTRUCTION PRIOR TO 5EGINNING WOR< OR ORDERING F,45RICATED 1"IATERIALS REQUIRED 1-0R CONSTRUCTION. 10. ENGINEER' S SE,4L fLu S 1-0R ,4PPROV,4L 01- STRUCTURAL DESIGN ONLT. 11. ,ALL GLASS IN HAZARDOUS LOCATIONS TO COMPLT WITH R308.4 THM 200. (302.9.1) 12. W,4LL ,4ND CEILING FINI5HE5 5I�,4LL H,4VE A FL,4MC E=5PRE,4D CL,455IFI,4TION OF NOT GRE,4TER R 13. W,4LL j4ND CEILING FINI5HE5 5H,4LL H,4VE ,4 5110<E=DEVELOPED INDEX OF NOT GRE,4TER TH,4N 450. (R302.9.2) 14. ,4LL TERiYIITE PROTECTION SHOULD COI IPLT WITH R310 , PROP05ED HOUSE IN VERY 1HE,4VT TERi IITE ,4RE,4. 1E5- ALL LUM5ER USED SHOULD HAVE QUAL ITT Mj4R<S PER R311.2 16. TILE TO BE IN5T,4LLE1) OVER FIBER=CEI IENT OR GL,455 1„Ij4T GTP51J1l 5,4C1<ER5. (RT02.4.1 ,AND R102.4.2.). IN SHOWER SURROUND AREAS. 11. WEAT14ERING IS NEGL IG ,45LE. 18. GTPSUM 1�0,4RD COMPLIES WITH 1-3C 702.3 SHOWER �, I" 2" T M. BATH LA 8'-0" C.L.G. LAv 2868 1 I I O I 2068 BF_ uN>LN I >„ O O _ 4 > �C � CID U 01 cs 0 O = Z 40 mo CD €Z N Na � I AV LINEN �� 1668BF I KID 8 m"� REF MAUL �.4TH 2 I 8'-0" CLCs. 2868 @ - 2868 20"x20' a wA 1 M 3'-4" 2'-10" 2,_ cLG. 10'-9" 5068 BF " 2'�0" 6'-4" m �a = - c I 0 i _ COUNTER - AT 36" AFF 1 Typ T LIFT TA 1 EG�ss AC COMP. O @ 'n uB We 'n H N DLG. 11 DRYWALL 3 R 14T ®®i„i FADER VAULTED CLCx. �' o �r 8'-0' E��55 8" HB o 1LU � � 0;� _ � c� 1LJLaL � � CS Tl 4" ° v I6„ ��4UND-RY I PRYER IVTR) 200 AMP PANEL 2868 SOLID _ CORE (20 MIN- 22" X- 54" FIRE RATED) ATTIC ACCESS (sELF-cLosING) L R-13 INSULATION BEARING WALL W/ - R-13 INSULATION 20'-0" 4" $ m CLG 1 3 O (TYP.) _\ 51_111 A'T'_21, "-,0" I � V ° - 5T. LUCK COUNTT 5UILDING DEPARTMENT PRODUCT APPROVAL REVIEU AFFIDAVIT - - •� 61-0" FOYER VAULTED CLG. T 5 -�" 4" 12 -4" / -` = 2 - 3 NTRY O _8 m cLG O O ` O WH i[l m BOLLARD PAINTED FINISH,g,R,g, ON BLOCK WALL(TYP.) IN GARAGE F- e 4068 BF OPENING SCHEDULE: SWING DOORS, OVERHEAD DOORS, SLIDING DOORS, FIXED GLASS, WINDOWS, & SKYLIGHTS: ° OPENING ID PRODUCT MODEL SIZE MANUFACTURER GLASS DESCRIPTION ATTACHMENT METHOD TYPE, SIZE, SPACING, &EMBEDMENT PRODUCT APPROVAL NUMBER U-FACTOR SHGC BUILDING DESIGN PRESSURE PRODUCT DESIGN PRESSURE 1 EXTERIOR DOOR METAL 192" X 84" CLOPAY N/A SEE DETAIL 1 A3 FL 16546.5 n/a n/a +31.86/ -38.74 +36.0 / -42.0 ° Q 2 EXTERIOR DOOR OPAQUE FIBERGLASS 36" X 80" THERMATRU N/A 1/4" x 3 1/4 " TAPCONS 6" FROM EDGES, 12" O.0 FIELD FL 20468.1 .14 .01 +35.96 -39.16 +50.0 -50.0 3 25 SINGLE HUNG VINYL SH-610 SERIES 38" X 63" CUSTOM WINDOW SYSTEMS ANNEALED 3/16" TAPCONS, 1 1/4 " EMBED.,6" MAX FROM EDGE, 14 1/2" MAX O.C. FIELD FL 17234.1 .29 .26 +31.52/-40.81 +50.0 -50.0 4 VINYL SH-610 SERIES 38" X B3" CUSTOM WINDOW SYSTEMS ANNEALED 3/16" TAPCONS, 1 1/4 " EMBED.,6" MAX FROM EDGE, 14 1/2" MAX O.C. FIELD FL 17234.1 .29 .29 +37.52 -40.81 +50.0 -50.0 ° EXTERORLSGDNDOOR ALUM. 9000 SERIES 12 X 80 CUSTOM WINDOW SYSTEMS TEMP. 3 i6 TAPCONS, 1 1 4 EMBED., 6 MAX FROM EDGE, 21 MAX O.C. FIELD FL 11908.1 .61 .33 +35.96 -39.16 +50.0 -50.0 6 25 SINGLE HUNG VINYL SH-610 SERIES 38" X 63 CUSTOM WINDOW SYSTEMS ANNEALED 3 i6" TAPCONS, 1 1/4 " EMBED.,6" MAX FROM EDGE, 14 1/2' MAX O.C. FIELD / / /„ FL 17234.1 29 29 +37.52 -40.81 / +50.0 -50.0 7 FIXED GLASS WINDOW VINYL PW-615 SERIES " „ 12 x 16 CUSTOM WINDOW SYSTEMS ANNEALED „ „ „ 3/16 TAPCONS, 1 1/4 EMBED,,6 MAX FROM EDGE, 9 1/2 MAX O.C. FIELD FL 17354.1 •28 .32 +31.52 -40.81 +50.0 -50.0 8 25 SINGLE HUNG VINYL SH-610 SERIES 38" X 63" CUSTOM WINDOW SYSTEMS ANNEALED 3/16" TAPCONS, 1 1/4 " EMBED,,6" MAX FROM EDGE, 14 1/2" MAX O.C. FIELD FL 17234.1 .29 .29 +37.52/-40.81 +50.0 -50.0 9 25 SINGLE HUNG VINYL SH-610 SERIES 38" X 63" CUSTOM WINDOW SYSTEMS ANNEALED 3/16" TAPCONS, 1 1/4 " EMBED.,6" MAX FROM EDGE, 14 1/2" MAX O.C. FIELD FL 17234.1 .29 1 .29 +37.52/-40.81 +50.0 -50.0 PRODUCT MODEL MANUFACTURER ATTACHMENT METHOD TYPE SIZE SPACING EMBEDMENT & STIFFENER ETC. PRODUCT APPROVAL 1 NUMBER BUILDING DESIGN PRESSURE PRODUCT DESIGN PRESSURE O Q O N _ 3 (EGRESS) e ROOF UNDERLAYMENT SOPREMA SOPREMA, INC PEEL AND STICK FL 2569.1 ROOF SHINGLES IKO INDUSTRIES FIBERGLASS REINFORCED SHINGLE, 6 FASTENERS PER CODE FL 30310.1 SIDING STUCCO RINKER (3) LAYERS STUCCO APPLIED TO MASONRY WALL HUDSON-4 -LH SOFFIT STUCCO RINKER (3) LAYERS STUCCO APPLIED TO HIGH RIBBED METAL LATH NAILED TO TRUSS TAILS PER FBC R703.6.1, 1 3/4" FASTENER 6" O.C. PER ASTM C1063 SEC. 7.10.2.3 Date: 01-30-21 HURRICANE PANELS METAL HURRICANE STORM PANEL MFG., INC. ELCO PANELMATE PLUS 1/4" DIA. SCREW, 1 3/4" MIN EMBED. , MIN. 12 " O.C. FL16293-R2 (SEE OPENING PRESSURES ABV.) SEE OPENING PRESSURES ABV.) Scale: AS SHOWN O 00 00 16'-0" 21'-4" 40'-m" LUALL LEGEND AREA CALCULAT ION15 Drawn: TS 4'-I0" 13'-10" S" CONC. BLOCK S'-1" AFf 4" WOOD BEARING PARTITION W1 R-13 INSULATION 4" INT. PARTITION W1 R-13 INSULATION 4" OR 6" INT. PARTITION FULL HEIGHT LIVING 1033 SF GARAGE 435 SF PORCH 13C SF ENTRY 24 5F L O O R FLAN 5C,4LE: 1/4'' = 1' -011 TOTAL 2420 5F