HomeMy WebLinkAboutAC Manual J (8)(1) 9 @ Load Short Form Job: 1448 wri htsoft Date: 3/29/2021 House By: Chris Bateman Air CaICs, LLC 7550 Hidden Hammock Ln,Vero Beach,FL32966 Phone:772.800.8413 Email:vickilyme@aircalcs.com Project Information For: Bolinski Residence,Air Conditioning Unlimited 8005 Banyon Ste,Fort Pierce,FL 34951 Design Information Htg Clg Infiltration Outside db(°F) 41 90 Method Simplified Inside db(°F) 70 75 Construction quality Average Design TD(°F) 29 15 Fireplaces 0 Daily range - L Inside humidity(%) 30 50 Moisture difference(gr/Ib) 2 57 HEATING EQUIPMENT COOLING EQUIPMENT Make Make Goodman Mfg. Trade Trade GOODMAN Model Cond GSX16S361A AHRI ref Coil ASPT47D14A AHRI ref 201785534 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input 7.7 kW Sensible cooling 24500 Btuh Heating output 26374 Btuh Latent cooling 10500 Btuh Temperature rise 21 °F Total cooling 35000 Btuh Actual airflow 1167 cfm Actual airflow 1167 cfm Air flow factor 0.049 cfm/Btuh Air flow factor 0.053 cfim/Btuh Static pressure 0.70 in H2O Static pressure 0.70 in H2O Space thermostat Load sensible heat ratio 0.76 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft2) (Btuh) (Btuh) (cfm) (cfm) Bed 3 162 2632 2485 129 131 Bed 2 163 3436 2110 168 111 Bath 59 1001 614 49 32 Lin 8 0 0 0 0 Hall 36 0 0 0 0 Hers 52 1198 417 59 22 His 49 646 246 32 13 Laundry 25 283 784 14 41 Foyer 57 1045 537 51 28 Kitchen 134 1415 3759 69 197 Cafe 147 3464 1874 170 98 Master Bed 211 2134 2665 105 140 Wtr Clst 26 897 352 44 18 M Bath 110 2465 1262 121 66 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. W rightsoft, 2021-Mar-30 13:21:13 A Right-Site®Universal 2021 21.0.05 RSU29066 Page 1 ACCA ...nts\WrightsoftHVAC\8005BanyonStPSLProp.rup Calc=MJ8 Front Door faces:N Great Room 301 3197 5102 157 268 House 1540 23815 22207 1167 1167 Other equip loads 2428 1289 Equip.@ 0.95 RSM 22416 Latent cooling 7429 TOTALS 1540 26243 29845 1167 1167 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. W rlghtsoft, 2021-Mar-30 13:21:13 A- II,-=Iae,-"e—«awa.—,, Right-Sute®Urrversal202121.0.05RSU29066 Page ACCA ...nts\WrightsoftHVAC\8005BaryonStPSLProp.rup Calc=MJ8 Front Door faces:N Building Job: 1448 +� wrightsoft° 9 Analysis Date: 3/29/2021 House By: Chris Bateman Air Calcs, LLC 7550 Hidden Hammock Ln,Vero Beach,FL32966 Phone:772.800.8413 Email:vickilyme@aircalcs.com Project • • For: Bolinski Residence,Air Conditioning Unlimited 8005 Banyon Ste,Fort Pierce,FL 34951 Design Conditions Location: Indoor: Heating Cooling St Lucie Co Intl,FL,US Indoor temperature(°F) 70 75 Elevation: 26 ft Design TD(°F) 29 15 Latitude: 28°N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 2.4 56.9 Dry bulb(°F) 41 90 Infiltration: Daily range(°F) - 15 ( L ) Method Simplified Wet bulb(°F) - 77 Construction quality Average Wind speed(mph) 15.0 7.5 Fireplaces 0 amme Component Btuh/ft2 Btuh %of load Walls 3.1 4710 17.9 Ventilation Glazing 17.5 3253 12.4 Walls Doors 3.7 140 0.5 Ceilings 1.0 1526 5.8 Ducts Floors 3.7 5753 21.9 Infiltration 1.8 2762 10.5 Glazing Ducts 5671 21.6 iupmidification 0 0 COeil ther ngs H Ventilation 2428 9.3 Infiltration Adjustments 0 Total 26243 100.0 Floors Component Btuh/ftz Btuh %of load Walls 1.9 2947 12.5 Walls Ventilation Glazing 22.7 4209 17.9 Doors 3.7 141 0.6 Internal Gains Ceilings 1.8 2778 11.8 Floors 0 0 0 Glazing Infiltration 0.5 772 3.3 Ducts 6339 27.0 Ventilation 1289 5.5 Other Internal gains 5020 21.4 Blower 0 0 Ceilings Adjustments 0 Ducts Total 23496 100.01Infiltration Latent Cooling Load=7429 Btuh Overall U-value=0.110 Btuh/ft2-°F Data entries checked. wrightsoft- 2021-Mar-30 13:21:13 ^.-k-I-1. °^.111-,1^,p°11 Right-SuteO Universal 2021 21.0.05 RSU29066 Page 1 ACCA nts\W rightsoft HVAC\8005 Banyon St PSL Prop.rup Calc=MJ8 Front Door faces:N om Constructions Job: 1448 +� wrightsoft Component Date: 3/29/2021 House By: Chris Bateman Air Calcs, LLC 7550 Hidden Hammock Ln,Vero Beach,FL32966 Phone:772.800.8413 Email:vickilyme@aircalcs.com Project • • For: Bolinski Residence,Air Conditioning Unlimited 8005 Banyon Ste,Fort Pierce,FL 34951 Design Conditions Location: Indoor: Heating Cooling St Lucie Co Intl,FL,US Indoor temperature(T) 70 75 Elevation: 26 ft Design TD(T) 29 15 Latitude: 28°N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(grAb) 2.4 56.9 Dry bulb(T) 41 90 Infiltration: Daily range(T) - 15 ( L ) Method Simplified Wet bulb(T) - 77 Construction quality Average Wind speed(mph) 15.0 7.5 Fireplaces 0 Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain ft' Btuh/ftUF W-T/Btuh Btuh/ft' Btuh Btuh/ft' Btuh Walls Blk Wall,Stucco Ext,R-4.1 Ext Bd inl,8"Thk, 1/2"Gyp Bd Int Fnsh ne 402 0.109 5.1 3.15 1266 2.02 810 se 194 0.109 5.1 3.15 612 2.02 391 sw 340 0.109 5.1 3.15 1072 2.02 686 w 51 0.109 5.1 3.15 160 2.02 103 nw 323 0.109 5.1 3.15 1017 2.02 651 all 1310 0.109 5.1 3.15 4127 2.02 2640 Partitions Fnn Wall, 1/2"Gyp Bd Ext,R-11 Cav Ins, 1/2"Gyp Bd Int Fnsh,2"A", 16" 192 0.101 11.0 2.94 564 1.46 280 OC Stud Knee wall,R-30 KW Ins, 1/2"Gyp Bd Int Fnsh 15 0.042 30.0 1.21 18 1.78 27 Windows Impact,Clear Low-e: Impact,Clear Low-e;NFRC rated(SHGC=0.24); ne 10 0.580 0 16.8 160 22.6 215 50%blinds 45°,medium;50%outdoor insect screen;foreground=green grass(0.23); 1 ft overhang(3.17 ft window ht, 1 ft sep.);6.8 ft head ht nw 10 0.580 0 16.8 160 22.6 215 all 19 0.580 0 16.8 320 22.6 430 Impact,Clear Lowe: Impact,Clear Lowe;NFRC rated(SHGC=0.24); ne 8 0.580 0 16.8 140 22.6 189 50%blinds 45°,medium;50%outdoor insect screen;foreground=green grass(0.23); 1 ft overhang(4.17 ft window ht, 1 ft sep.);6.8 ft head ht Impact,Clear Low-e: Impact,Clear Low-e;NFRC rated(SHGC=0.16); se 8 0.490 0 14.2 107 14.2 107 50%blinds 45°,medium;50%outdoor insect screen;foreground=green grass(0.23); 1 ft overhang(1.25 ft window ht, 1 ft sep.);6.8 ft head ht se 4 0.490 0 14.2 53 14.2 53 all 11 0.490 0 14.2 160 14.2 160 Impact,Clear Low-e: Impact,Clear Low-e;NFRC rated(SHGC=0.22); se 47 0.620 0 18.0 836 21.4 995 50%blinds 45°,medium;50%outdoor insect screen;foreground=green grass(0.23); 1 ft overhang(5.17 ft window ht, 1 ft sep.);6.8 ft head ht Impact,Clear Lowe: Impact,Clear Lowe;NFRC rated(SHGC=0.24); sw 31 0.580 0 16.8 525 21.8 681 50%blinds 45°,medium;50%outdoor insect screen;foreground=green grass(0.23); 1 ft overhang(5.2 ft window ht, 1 ft sep.);6.8 ft head ht nw 16 0.580 0 16.8 262 22.6 353 all 47 0.580 0 16.8 787 22.1 1034 -Pk wrightsoft"' 2021-Mar-3013:21:13 --k=de-•,.ea«a-a. P=. Right-Sute®Universal 202121.0.05RSU29066 Pagel ACCA nts\Wrightsoft HVAC\8005 Banyon St PSL Prop.rup Calc=MJ8 Front Door faces:N Impact,Clear Lowe: Impact,Clear Lowe;NFRC rated(SHGC=0.21); nw 54 0.650 0 18.8 1010 22.0 1181 50%blinds 45°,medium;50%outdoor insect screen;foreground=green grass(0.23);6.5 ft overhang(6.7 ft window ht, 1 ft sep.);6.8 ft head ht Doors Fbrgls Door ne 18 0.127 7.0 3.69 66 3.73 67 se 20 0.127 7.0 3.69 74 3.73 75 all 38 0.127 7.0 3.69 140 3.73 141 Ceilings Attic,Shngl Roof,R-30 Ceil Ins, 1/2"Gyp Bd Int Fnsh 1540 0.034 30.0 0.99 1526 1.80 2778 Floors On Grade Depth,Tile Flr Fnsh 201 0.989 0 28.7 5753 0 0 'Pk wrightsoft- 2021-Mar-3013:21:13 --1-de-•,.e a«a-a. P=. Right-Site®Urrversal 2021 21.0.05 RSU29066 Page 2 ACCA nts\WrightsoftHVAC\8005BaryonStPSLProp.rup Calc=MJ8 Front Door faces:N Pro S Job: 1448 +� wrightsoft° Project Date: 3/29/2021 House By: Chris Bateman Air Calcs, LLC 7550 Hidden Hammock Ln,Vero Beach,FL32966 Phone:772.800.8413 Email:vickilyme@aircalcs.com Project • • For: Bolinski Residence,Air Conditionin�Unlimited 8005 Banyon Ste,Fort Pierce,FL 3 951 Notes: Design Information Weather: St Lucie Co Intl,FL,US Winter Design Conditions Summer Design Conditions Outside db 41 °F Outside db 90 °F Inside db 70 °F Inside db 75 °F Design TD 29 °F Design TD 15 °F Daily range L Relative humidity 50 % Moisture difference 57 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 18144 Btuh Structure 15868 Btuh Ducts 5671 Btuh Ducts 6339 Btuh Central vent(76 cfm) 2428 Btuh Central vent(76 cfm) 1289 Btuh Outside air Outside air Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 26243 Btuh Use manufacturer's data n Rate/swin multiplier 0.95 Infiltration Equipmen�sensible load 22416 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2563 Btuh Ducts 1922 Btuh Central vent(76 cfm) 2944 Btuh Heating Cooling Outside air Area(ft�) 1540 1540 Equipment latent load 7429 Btuh Volume(ft3) 13686 13686 Air changes/hour 0.38 0.20 Equipment Total Load(Sen+Lat) 29845 Btuh Equiv.AVF(cfm) 87 46 Req.total capacity at 0.70 SHR 2.7 ton Heating Equipment Summary Cooling Equipment Summary Make Make Goodman Mfg. Trade Trade GOODMAN Model Cond GSX16S361A AHRI ref Coil ASPT47D14A AHRI ref 201785534 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input 7.7 kW Sensible cooling 24500 Btuh Heating output 26374 Btuh Latent cooling 10500 Btuh Temperature rise 21 °F Total cooling 35000 Btuh Actual airflow 1167 cfm Actual airflow 1167 cfm Air flow factor 0.049 cfm/Btuh Air flow factor 0.053 cfm/Btuh Static pressure 0.70 in H2O Static pressure 0.70 in H2O Space thermostat Load sensible heat ratio 0.76 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrigF�tsoft 2021-Mar-3013:21:13 Right-Site®Universal 2021 21.0.05 RSU29066 Page 1 ACCA nts\Wrightsoft HVAC\8005 Banyon St PSL Prop.rup Calc=MJ8 Front Door faces:N + wrightsoft°° Right-J®Worksheet Job: 1448 House Date: 3/29/2021 By: Chris Bateman Air Calcs, LLC 7550 Hidden Hammock Ln,Vero Beach,FL32966 Phone:772.800.8413 Email:vickilyme@aircalcs.com 1 Room name House Bed 3 2 E)posed wal I 200.6 ft 16.5 ft 3 Room height 8.9 ft 10.0 ft heat/cool 4 Room dimensions 1.0 x 161.9 ft 5 Room area 1539.5 ft2 161.9 ft' Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/R2--°F) (Btuh/fl) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 Blk Wall,Stucco Ext 0.109 ne 3.15 2.02 438 402 1266 810 0 0 0 0 Impact,Clear Lowe 0.580 ne 16.82 22.64 10 0 160 215 0 0 0 0 Impaa Clear Low-e 0.580 ne 16.82 22.64 8 0 140 189 0 0 0 0 D Fbrgls Door 0.127 ne 3.69 3.73 18 18 66 67 0 0 0 0 11 Blk Wall,Stucco Ext 0.109 se 3.15 2.02 272 194 612 391 120 82 257 164 Impaa Clear Low-e 0.490 se 14.21 14.22 8 4 107 107 8 4 107 107 Impaa Clear Low-e 0.490 se 14.21 14.22 4 2 53 53 0 0 0 0 Impaa Clear Low-e 0.620 se 17.98 21.39 47 6 836 995 31 4 557 663 D Fbrgls Door 0.127 se 3.69 3.73 20 20 74 75 0 0 0 0 �j Blk Wall,Stucco Ext 0.109 sw 3.15 2.02 372 340 1072 686 45 45 142 91 t-G Impact,ClearLow-e 0.580 sw 16.82 21.82 31 4 525 681 0 0 0 0 W Blk Wall,Stucco Ext 0.109 w 3.15 2.02 51 51 160 103 0 0 0 0 BIk Wall,Stucco Ext 0.109 nw 3.15 2.02 402 323 1017 651 0 0 0 0 Impact,ClearLow-e 0.580 nw 16.82 22.64 10 0 160 215 0 0 0 0 G Impact,ClearLow-e 0.580 nw 16.82 22.64 16 0 262 353 0 0 0 0 Impact,ClearLow-e 0.650 nw 18.85 22.04 54 0 1010 1181 0 0 0 0 P Frm Wall,12"Gvp B 0.101 2.94 1.46 192 192 564 280 0 0 0 0 P Knee wall,R-30 KW I 0.042 1.21 1.78 15 15 18 27 0 0 0 0 C Attic,Shngl Roof,R 0.034 0.99 1.80 1540 1540 1526 2778 162 162 160 292 F On Grade Depth,Tile 0.989 28.68 0.00 1540 201 5753 0 162 17 473 0 6 c)AED excursion 221 106 Envelope loss/gain 15382 10076 1696 1423 12 a) Infiltration 2762 772 297 83 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 4 920 0 0 Appliances/other 4100 250 Subtotal(lines 6 to 13) 18144 15868 1993 1756 Less extemalload 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 12 20 14 Subtotal 18144 15868 2005 1776 15 Dud loads 31% 40% 5671 6339 31% 40%1 627 709 FFTotal room load 23815 22207 2632 2485 Air required(dm) 1167 1167 129 131 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. �� rigF�tsoft° 2021-Mar-3013:21:13 Right-Sute@Unversal2021 21.0.05 RSU29066 Page 1 nts\Wri htsoftHVAC\8005BarryonStPSLProp.rp Calc=MJ8 Front Door faces:N + wrightsoft°° Right-J®Worksheet Job: 1448 House Date: 3/29/2021 By: Chris Bateman Air Calcs, LLC 7550 Hidden Hammock Ln,Vero Beach,FL32966 Phone:772.800.8413 Email:vickilyme@aircalcs.com 1 Room name Bed 2 Bath 2 E)posed wal I 32.5 It 8.5 ft 3 Room height 8.0 It heat/000l 8.0 It heat/000l 4 Room dimensions 1.0 x 163.3 It 1.0 x 58.8 It 5 Room area 163.3 fF 58.8 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/R2--°F) (Btuh/fl) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 Blk Wall,Stucco Ext 0.109 ne 3.15 2.02 108 108 340 218 68 60 188 120 Impact,Clear Lowe 0.580 ne 16.82 22.64 0 0 0 0 0 0 0 0 Impaa Clear Low-e 0.580 ne 16.82 22.64 0 0 0 0 8 0 140 189 D Fbrgls Door 0.127 ne 3.69 3.73 0 0 0 0 0 0 0 0 11 Blk Wall,Stucco Ext 0.109 se 3.15 2.02 92 77 241 154 0 0 0 0 Impaa Clear Low-e 0.490 se 14.21 14.22 0 0 0 0 0 0 0 0 Impaa Clear Low-e 0.490 se 14.21 14.22 0 0 0 0 0 0 0 0 Impaa Clear Low-e 0.620 se 17.98 21.39 16 2 279 332 0 0 0 0 D Fbrgls Door 0.127 se 3.69 3.73 0 0 0 0 0 0 0 0 �j Blk Wall,Stucco Ext 0.109 sw 3.15 2.02 60 60 189 121 0 0 0 0 t-G Impact,ClearLow-e 0.580 sw 16.82 21.82 0 0 0 0 0 0 0 0 W Blk Wall,Stucco Ext 0.109 w 3.15 2.02 0 0 0 0 0 0 0 0 BIk Wall,Stucco Ext 0.109 nw 3.15 2.02 0 0 0 0 0 0 0 0 Impact,ClearLow-e 0.580 nw 16.82 22.64 0 0 0 0 0 0 0 0 G Impact,ClearLow-e 0.580 nw 16.82 22.64 0 0 0 0 0 0 0 0 Impact,ClearLow-e 0.650 nw 18.85 22.04 0 0 0 0 0 0 0 0 P Frm Wall,1/2"Gvp B 0.101 2.94 1.46 0 0 0 0 0 0 0 0 P Knee wall,R-30 KW I 0.042 1.21 1.78 0 0 0 0 0 0 0 0 C Attic,Shngl Roof,R 0.034 0.99 1.80 163 163 162 295 59 59 58 106 F On Grade Depth,Tile 0.989 28.68 0.00 163 33 932 0 59 9 244 0 6 c)AED excursion -3 -28 Envelope loss/gain 2143 1116 630 387 12 a) Infiltration 468 131 123 34 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 0 0 0 0 Appliances/other 250 0 Subtotal(lines 6 to 13) 2611 1497 753 421 Less extemalload 0 0 0 0 Less transfer 0 0 0 0 Redistribution 6 11 10 18 14 Subtotal 2618 1508 763 439 15 Dud loads 31% 40%1 8181 602 31% 40%1 238 175 Total room load 3436 2110 1001 614 Air required(dm) 168 111 49 32 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. �� rigF�tsoft° 2021-Mar-3013:21:13 Right-Suite@Unversal2021 21.0.05 RSU29066 Page 2 nts\Wri htsoftHVAC\8005BanyonStPSLProp.rp Calc=MJ8 Front Door faces:N + wrightsoft°° Right-J®Worksheet Job: 1448 House Date: 3/29/2021 By: Chris Bateman Air Calcs, LLC 7550 Hidden Hammock Ln,Vero Beach,FL32966 Phone:772.800.8413 Email:vickilyme@aircalcs.com 1 Room name Lin Hall 2 E)q)osed wal I O ft O ft 3 Room height 8.0 It heat/000l 8.0 It heat/000l 4 Room dimensions 1.0 x 8.1 ft ft 1.0 x 36.4 5 Room area 8.1 ft2 36.4 ft Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/R2--°F) (Btuh/fl) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 Bilk Wall,Stucco Ext 0.109 ne 3.15 2.02 0 0 0 0 0 0 0 0 Impact,Clear Lowe 0.580 ne 16.82 22.64 0 0 0 0 0 0 0 0 Impaa Clear Low-e 0.580 ne 16.82 22.64 0 0 0 0 0 0 0 0 D Fbrgls Door 0.127 ne 3.69 3.73 0 0 0 0 0 0 0 0 11 BilkWall,Stucco Ext 0.109 se 3.15 2.02 0 0 0 0 0 0 0 0 Impaa Clear Low-e 0.490 se 14.21 14.22 0 0 0 0 0 0 0 0 Impaa Clear Low-e 0.490 se 14.21 14.22 0 0 0 0 0 0 0 0 Impaa Clear Low-e 0.620 se 17.98 21.39 0 0 0 0 0 0 0 0 D Fbrgls Door 0.127 se 3.69 3.73 0 0 0 0 0 0 0 0 �j Bilk Wall,Stucco Ext 0.109 sw 3.15 2.02 0 0 0 0 0 0 0 0 t-G Impact,ClearLow-e 0.580 sw 16.82 21.82 0 0 0 0 0 0 0 0 W Bilk Wall,Stucco Ext 0.109 w 3.15 2.02 0 0 0 0 0 0 0 0 BIk Wall,Stucco Ext 0.109 nw 3.15 2.02 0 0 0 0 0 0 0 0 Impact,ClearLow-e 0.580 nw 16.82 22.64 0 0 0 0 0 0 0 0 G Impact,ClearLow-e 0.580 nw 16.82 22.64 0 0 0 0 0 0 0 0 Impact,ClearLow-e 0.650 nw 18.85 22.04 0 0 0 0 0 0 0 0 P Frm Wall,IQ"Gvp B 0.101 2.94 1.46 0 0 0 0 0 0 0 0 P Knee wall,R-30 KW I 0.042 1.21 1.78 0 0 0 0 0 0 0 0 C Attic,Shngl Roof,R 0.034 0.99 1.80 8 8 8 15 36 36 36 66 F On Grade Depth,Tile 0.989 28.68 0.00 8 0 0 0 36 0 0 0 6 c)AED excursion -1 -4 Envelope loss/gain 8 14 36 62 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 8 14 36 62 Less extemalload 0 0 0 0 Less transfer 0 0 0 0 Redistribution -8 -14 -36 -62 14 Subtotal 0 0 0 0 15 Dud loads 31% 40%1 0 0 31% 40%1 0 0 FFTotal room load 0 0 0 ::100 Airquired(dm) 0 0 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. �� rigF�tsoft° 2021-Mar-3013:21:13 Right-Suite@Unversal2021 21.0.05 RSU29066 Page 3 nts\Wri htsoftHVAC\8005BanyonStPSLProp.rp Calc=MJ8 Front Door faces:N + wrightsoft°° Right-J®Worksheet Job: 1448 House Date: 3/29/2021 By: Chris Bateman Air Calcs, LLC 7550 Hidden Hammock Ln,Vero Beach,FL32966 Phone:772.800.8413 Email:vickilyme@aircalcs.com 1 Room name Hers His 2 E)posed wal I 14.5 It 8.5 ft 3 Room height 8.0 It heat/000l 8.0 It heat/000l 4 Room dimensions 8.0 x 6.5 It 7.5 x 6.5 It 5 Room area 52.0 ft' 48.8 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/R2--°F) (Btuh/fl) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 Blk Wall,Stucco Ext 0.109 ne 3.15 2.02 0 0 0 0 0 0 0 0 Impact,Clear Lowe 0.580 ne 16.82 22.64 0 0 0 0 0 0 0 0 Impaa Clear Low-e 0.580 ne 16.82 22.64 0 0 0 0 0 0 0 0 D Fbrgls Door 0.127 ne 3.69 3.73 0 0 0 0 0 0 0 0 11 Blk Wall,Stucco Ext 0.109 se 3.15 2.02 0 0 0 0 0 0 0 0 Impaa Clear Low-e 0.490 se 14.21 14.22 0 0 0 0 0 0 0 0 Impaa Clear Low-e 0.490 se 14.21 14.22 0 0 0 0 0 0 0 0 Impaa Clear Low-e 0.620 se 17.98 21.39 0 0 0 0 0 0 0 0 D Fbrgls Door 0.127 se 3.69 3.73 0 0 0 0 0 0 0 0 �j Blk Wall,Stucco Ext 0.109 sw 3.15 2.02 52 52 164 105 0 0 0 0 t-G Impact,ClearLow-e 0.580 sw 16.82 21.82 0 0 0 0 0 0 0 0 W Blk Wall,Stucco Ext 0.109 w 3.15 2.02 0 0 0 0 0 0 0 0 BIk Wall,Stucco Ext 0.109 nw 3.15 2.02 0 0 0 0 0 0 0 0 Impact,ClearLow-e 0.580 nw 16.82 22.64 0 0 0 0 0 0 0 0 G Impact,ClearLow-e 0.580 nw 16.82 22.64 0 0 0 0 0 0 0 0 Impact,ClearLow-e 0.650 nw 18.85 22.04 0 0 0 0 0 0 0 0 P Frm Wall,12"Gvp B 0.101 2.94 1.46 64 64 188 93 68 68 200 99 P Knee wall,R-30 KW I 0.042 1.21 1.78 0 0 0 0 0 0 0 0 C Attic,Shngl Roof,R 0.034 0.99 1.80 52 52 52 94 49 49 48 88 F On Grade Depth,Tile 0.989 28.68 0.00 52 15 416 0 49 9 244 0 6 c)AED excursion -20 -12 Envelope loss/gain 819 272 492 175 12 a) Infiltration 94 26 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 913 298 492 175 Less extemalload 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 913 298 492 175 15 Dud loads 31% 40%1 2851 119 31% 40%1 154 70 Total room load 1198 417 646 246 Air required(dm) 59 22 32 13 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. �� rigF�tsoft° 2021-Mar-3013:21:13 Right-Sute@Unversal202121.0.05RSU29066 Page nts\Wri htsoftHVAC\8005BanyonStPSLProp.rp Calc=MJ8 Front Door faces:N + wrightsoft°° Right-J®Worksheet Job: 1448 House Date: 3/29/2021 By: Chris Bateman Air Calcs, LLC 7550 Hidden Hammock Ln,Vero Beach,FL32966 Phone:772.800.8413 Email:vickilyme@aircalcs.com 1 Room name Laundry Foyer 2 E)posed wal I 3.5 ft 10.0 ft 3 Room height 10.0 It heat/000l 10.0 It heat/cool 4 Room dimensions 3.5 x 7.0 It 6.0 x 9.5 ft 5 Room area 24.5 ft' 57.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/R2--°F) (Btuh/fl) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 Blk Wall,Stucco Ext 0.109 ne 3.15 2.02 0 0 0 0 0 0 0 0 Impact,Clear Lowe 0.580 ne 16.82 22.64 0 0 0 0 0 0 0 0 Impaa Clear Low-e 0.580 ne 16.82 22.64 0 0 0 0 0 0 0 0 D Fbrgls Door 0.127 ne 3.69 3.73 0 0 0 0 0 0 0 0 11 Blk Wall,Stucco Ext 0.109 se 3.15 2.02 0 0 0 0 60 36 114 73 Impaa Clear Low-e 0.490 se 14.21 14.22 0 0 0 0 0 0 0 0 Impaa Clear Low-e 0.490 se 14.21 14.22 0 0 0 0 4 2 53 53 Impaa Clear Low-e 0.620 se 17.98 21.39 0 0 0 0 0 0 0 0 D Fbrgls Door 0.127 se 3.69 3.73 0 0 0 0 20 20 74 75 �j Blk Wall,Stucco Ext 0.109 sw 3.15 2.02 0 0 0 0 0 0 0 0 t-G Impact,ClearLow-e 0.580 sw 16.82 21.82 0 0 0 0 0 0 0 0 W Blk Wall,Stucco Ext 0.109 w 3.15 2.02 0 0 0 0 0 0 0 0 BIk Wall,Stucco Ext 0.109 nw 3.15 2.02 0 0 0 0 0 0 0 0 Impact,ClearLow-e 0.580 nw 16.82 22.64 0 0 0 0 0 0 0 0 G Impact,ClearLow-e 0.580 nw 16.82 22.64 0 0 0 0 0 0 0 0 Impact,ClearLow-e 0.650 nw 18.85 22.04 0 0 0 0 0 0 0 0 P Frm Wall,12"Gvp B 0.101 2.94 1.46 28 28 82 41 32 32 94 47 P Knee wall,R-30 KW I 0.042 1.21 1.78 7 7 8 12 8 8 10 14 C Attic,Shngl Roof,R 0.034 0.99 1.80 25 25 24 44 57 57 56 103 F On Grade Depth,Tile 0.989 28.68 0.00 25 4 100 0 57 10 287 0 6 c)AED excursion -37 -12 Envelope loss/gain 215 60 688 353 12 a) Infiltration 0 0 108 30 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 0 0 0 0 Appliances/other 500 0 Subtotal(lines 6 to 13) 215 560 796 384 Less extemalload 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 215 560 796 384 15 Dud loads 31% 40%1 671 224 31% 40%1 249 153 Total room load 283 784 1045 537 Air required(dm) 14 41 51 28 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. �� rigF�tsoft° 2021-Mar-3013:21:13 Right-Suite@Unversal2021 21.0.05 RSU29066 Page 5 nts\Wri htsoftHVAC\8005BanyonStPSLProp.rp Calc=MJ8 Front Door faces:N + wrightsoft°° Right-J®Worksheet Job: 1448 House Date: 3/29/2021 By: Chris Bateman Air Calcs, LLC 7550 Hidden Hammock Ln,Vero Beach,FL32966 Phone:772.800.8413 Email:vickilyme@aircalcs.com 1 Room name Kitchen Cafe 2 E)q)osed wal I 11.0 ft 31.1 it 3 Room height 9.0 ft heat/000l 9.0 ft heat/cool 4 Room dimensions 1.0 x 134.4 ft 1.0 x 147.3 it 5 Room area 134.4 fF 147.3 fF Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/R2--°F) (Btuh/fl) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 Blk Wall,Stucco Ext 0.109 ne 3.15 2.02 99 90 282 180 95 95 298 190 Impact,Clear Lowe 0.580 ne 16.82 22.64 10 0 160 215 0 0 0 0 Impaa Clear Low-e 0.580 ne 16.82 22.64 0 0 0 0 0 0 0 0 D Fbrgls Door 0.127 ne 3.69 3.73 0 0 0 0 0 0 0 0 11 Blk Wall,Stucco Ext 0.109 se 3.15 2.02 0 0 0 0 0 0 0 0 Impaa Clear Low-e 0.490 se 14.21 14.22 0 0 0 0 0 0 0 0 Impaa Clear Low-e 0.490 se 14.21 14.22 0 0 0 0 0 0 0 0 Impact,Clear Low-e 0.620 se 17.98 21.39 0 0 0 0 0 0 0 0 D Fbrgls Door 0.127 se 3.69 3.73 0 0 0 0 0 0 0 0 �j Blk Wall,Stucco Ext 0.109 sw 3.15 2.02 0 0 0 0 23 23 71 45 t-G Impact,ClearLow-e 0.580 sw 16.82 21.82 0 0 0 0 0 0 0 0 W Blk Wall,Stucco Ext 0.109 w 3.15 2.02 0 0 0 0 51 51 160 103 BIk Wall,Stucco Ext 0.109 nw 3.15 2.02 0 0 0 0 113 97 305 195 Impact,ClearLow-e 0.580 nw 16.82 22.64 0 0 0 0 0 0 0 0 G Impact,ClearLow-e 0.580 nw 16.82 22.64 0 0 0 0 16 0 262 353 Impact,ClearLow-e 0.650 nw 18.85 22.04 0 0 0 0 0 0 0 0 P Frm Wall,1/2"Gvp B 0.101 2.94 1.46 0 0 0 0 0 0 0 0 P Knee wall,R-30 KW I 0.042 1.21 1.78 0 0 0 0 0 0 0 0 C Attic,Shngl Roof,R 0.034 0.99 1.80 134 134 133 243 147 147 146 266 F On Grade Depth,Tile 0.989 28.68 0.00 134 11 315 0 147 31 892 0 6 c)AED excursion -178 45 Envelope loss/gain 890 460 2134 1198 12 a) Infiltration 178 50 505 141 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 2 460 0 0 Appliances/other 1700 0 Subtotal(lines 6 to 13) 1069 2670 2639 1339 Less extemalload 0 0 0 0 Less transfer 0 0 0 0 Redistribution 10 16 0 0 14 Subtotal 1078 2686 2639 1339 15 Dud loads 31% 40%1 3371 1073 31% 40%1 825 535 Total room load 1415 3759 3464 1874 Air required(dm) 69 197 170 98 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. �� rigF�tsoft° 2021-Mar-3013:21:13 Right-Suite@Unversal2021 21.0.05 RSU29066 Page 6 nts\Wri htsoftHVAC\8005BanyonStPSLProp.rp Calc=MJ8 Front Door faces:N + wrightsoft°° Right-J®Worksheet Job: 1448 House Date: 3/29/2021 By: Chris Bateman Air Calcs, LLC 7550 Hidden Hammock Ln,Vero Beach,FL32966 Phone:772.800.8413 Email:vickilyme@aircalcs.com 1 Room name Master Bed Wtrclst 2 E)q)osed wal I 14.5 It 9.5 ft 3 Room height 8.0 It heat/000l 8.0 It heat/000l 4 Room dimensions 1.0 x 211.3 It 3.0 x 8.5 It 5 Room area 211.3 fF 25.5 ft' Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/R2--°F) (Btuh/fl) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 Blk Wall,Stucco Ext 0.109 ne 3.15 2.02 0 0 0 0 52 34 108 69 Impact,Clear Lowe 0.580 ne 16.82 22.64 0 0 0 0 0 0 0 0 Impaa Clear Low-e 0.580 ne 16.82 22.64 0 0 0 0 0 0 0 0 D Fbrgls Door 0.127 ne 3.69 3.73 0 0 0 0 18 18 66 67 11 Blk Wall,Stucco Ext 0.109 se 3.15 2.02 0 0 0 0 0 0 0 0 Impaa Clear Low-e 0.490 se 14.21 14.22 0 0 0 0 0 0 0 0 Impaa Clear Low-e 0.490 se 14.21 14.22 0 0 0 0 0 0 0 0 Impaa Clear Low-e 0.620 se 17.98 21.39 0 0 0 0 0 0 0 0 D Fbrgls Door 0.127 se 3.69 3.73 0 0 0 0 0 0 0 0 �j Blk Wall,Stucco Ext 0.109 sw 3.15 2.02 108 77 242 155 0 0 0 0 t-G Impact,ClearLow-e 0.580 sw 16.82 21.82 31 4 525 681 0 0 0 0 W Blk Wall,Stucco Ext 0.109 w 3.15 2.02 0 0 0 0 0 0 0 0 BIk Wall,Stucco Ext 0.109 nw 3.15 2.02 8 8 25 16 24 24 76 48 Impact,ClearLow-e 0.580 nw 16.82 22.64 0 0 0 0 0 0 0 0 G Impact,ClearLow-e 0.580 nw 16.82 22.64 0 0 0 0 0 0 0 0 Impact,ClearLow-e 0.650 nw 18.85 22.04 0 0 0 0 0 0 0 0 P Frm Wall,1/2"Gvp B 0.101 2.94 1.46 0 0 0 0 0 0 0 0 P Knee wall,R-30 KW I 0.042 1.21 1.78 0 0 0 0 0 0 0 0 C Attic,Shngl Roof,R 0.034 0.99 1.80 211 211 209 381 26 26 25 46 F On Grade Depth,Tile 0.989 28.68 0.00 211 15 416 0 26 10 272 0 6 c)AED excursion 113 -17 Envelope loss/gain 1417 1346 547 213 12 a) Infiltration 209 58 137 38 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 0 0 0 0 Appliances/other 500 0 Subtotal(lines 6 to 13) 1626 1905 684 251 Less extemalload 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1626 1905 684 251 15 Dud loads 31% 40%1 5081 761 31% 40%1 214 100 Total room load 2134 2665 897 352 Air required(dim) 105 140 44 18 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. �� rigF�tsoft° 2021-Mar-3013:21:13 Right-Suite@Unversal2021 21.0.05 RSU29066 Page 7 nts\Wri htsoftHVAC\8005BanyonStPSLProp.rp Calc=MJ8 Front Door faces:N + wrightsoft°° Right-J®Worksheet Job: 1448 House Date: 3/29/2021 By: Chris Bateman Air Calcs, LLC 7550 Hidden Hammock Ln,Vero Beach,FL32966 Phone:772.800.8413 Email:vickilyme@aircalcs.com 1 Room name MBath Great Room 2 E)q)osed wal I 24.0 it 16.5 it 3 Room height 8.0 it heat/cool 10.0 it heat/cool 4 Room dimensions 1.0 x 109.8 it 1.0 x 300.8 it 5 Room area 109.8 fF 300.8 fF Ty Construction U-value Or HTM Area (fl) Load Area (fl) Load number (Btuh/R2--°F) (Btuh/fl) or perimeter (it) (Btuh) or perimeter (it) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 Blk Wall,Stucco Ext 0.109 ne 3.15 2.02 16 16 50 32 0 0 0 0 Impact,Clear Lowe 0.580 ne 16.82 22.64 0 0 0 0 0 0 0 0 Impaa Clear Low-e 0.580 ne 16.82 22.64 0 0 0 0 0 0 0 0 D Fbrgls Door 0.127 ne 3.69 3.73 0 0 0 0 0 0 0 0 11 Blk Wall,Stucco Ext 0.109 se 3.15 2.02 0 0 0 0 0 0 0 0 Impaa Clear Low-e 0.490 se 14.21 14.22 0 0 0 0 0 0 0 0 Impaa Clear Low-e 0.490 se 14.21 14.22 0 0 0 0 0 0 0 0 Impact,Clear Low-e 0.620 se 17.98 21.39 0 0 0 0 0 0 0 0 D Fbrgls Door 0.127 se 3.69 3.73 0 0 0 0 0 0 0 0 �j Blk Wall,Stucco Ext 0.109 sw 3.15 2.02 84 84 265 169 0 0 0 0 t-G Impact,ClearLow-e 0.580 sw 16.82 21.82 0 0 0 0 0 0 0 0 W Blk Wall,Stucco Ext 0.109 w 3.15 2.02 0 0 0 0 0 0 0 0 BIk Wall,Stucco Ext 0.109 nw 3.15 2.02 92 83 260 166 165 111 351 225 Impact,ClearLow-e 0.580 nw 16.82 22.64 10 0 160 215 0 0 0 0 G Impact,ClearLow-e 0.580 nw 16.82 22.64 0 0 0 0 0 0 0 0 Impact,ClearLow-e 0.650 nw 18.85 22.04 0 0 0 0 54 0 1010 1181 P Frm Wall,1/2"Gvp B 0.101 2.94 1.46 0 0 0 0 0 0 0 0 P Knee wall,R-30 KW I 0.042 1.21 1.78 0 0 0 0 0 0 0 0 C Attic,Shngl Roof,R 0.034 0.99 1.80 110 110 109 198 301 301 298 543 F On Grade Depth,Tile 0.989 28.68 0.00 110 24 688 0 301 17 473 0 6 c)AED excursion 24 244 Envelope loss/gain 1532 805 2133 2192 12 a) Infiltration 346 97 297 83 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 0 0 2 460 Appliances/other 0 900 Subtotal(lines 6 to 13) 1878 902 2430 3635 Less extemalload 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 6 10 14 Subtotal 1878 902 2436 3646 15 Dud loads 31% 40% 587 360 31% 40% 761 1456 FFTotal room load 2465 1262 3197 5102 Airrequired(dm) 121 66 157 268 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. �� rigF�tsoft° 2021-Mar-3013:21:13 Right-Suite@Unversal2021 21.0.05 RSU29066 Page 8 nts\Wri htsoftHVAC\8005BanyonStPSLProp.rp Calc=MJ8 Front Door faces:N Duct System Summary Job: 1448 +� wrightsoft D S S Date: 3/29/2021 House By: Chris Bateman Air Calcs, LLC 7550 Hidden Hammock Ln,Vero Beach,FL32966 Phone:772.800.8413 Email:vickilyme@aircalcs.mm Project Information For: Bolinski Residence,Air Conditioning Unlimited 8005 Banyon Ste,Fort Pierce,FL 34951 Heating Cooling External static pressure 0.70 in H2O 0.70 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.70 in H2O 0.70 in H2O Supply/return available pressure 0.470/0.230 in H2O 0.470/0.230 in H2O Lowest friction rate 0.264 in/100ft 0.264 in/100ft Actual airflow 1167 cfm 1167 cfm Total effective length(TEL) 265 ft SupplyDetail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (cfm) (cfm) FIR (in) (in) Matl Ln(ft) Ln(ft) Trunk Bat, h 1001 59 39 0.275 5.0 Ox0 VIFx 45.8 125.0 st3 Bed 2 h 3436 202 133 0.266 8.0 Ox 0 VI Fx 51.6 125.0 st3 Bed 3 c 2485 155 157 0.350 7.0 Ox 0 VI Fx 29.2 105.0 st1 Cate h 3464 204 118 0.264 8.0 Ox0 VIFx 53.2 125.0 st3 Foyer h 1045 61 34 0.338 5.0 Ox0 VIFx 34.1 105.0 st1 Great Room c 2551 94 161 0.346 7.0 Ox 0 VI Fx 30.8 105.0 st1 Great Room-A c 2551 94 161 0.347 7.0 Ox 0 VI Fx 30.6 105.0 st1 Hers h 1198 70 26 0.396 5.0 Ox 0 VI Fx 18.6 100.0 st2 His h 646 38 15 0.400 4.0 Ox0 VI Fx 17.6 100.0 st2 Kitchen c 3759 83 237 0.280 8.0 Ox0 VI Fx 43.0 125.0 st3 Laundry c 784 17 49 0.345 4.0 Ox0 VI Fx 31.1 105.0 st1 M Bath h 2465 145 80 0.313 7.0 Ox 0 VI Fx 29.9 120.0 st4 Master Bed c 1333 63 84 0.394 5.0 Ox 0 VI Fx 19.4 100.0 st2 Master Bed-A c 1333 63 84 0.397 5.0 Ox 0 VI Fx 18.4 100.0 st2 wtClst h 897 53 22 0.311 4.0 Ox0 VIFx 31.2 120.0 st4 SupplyDetail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FIR (fpm) (in) (in) Material Trunk st3 PeakAVF 548 527 0.264 697 12.0 0 x 0 VinlFlx st1 st1 PeakAVF 968 1088 0.264 780 16.0 0 x 0 VinlFlx st4 PeakAVF 198 102 0.311 740 7.0 0 x 0 VinlFlx st2 st2 PeakAVF 432 312 0.311 791 10.0 0 x 0 VinlFlx wrightsoft® 2021-Mar-3013:21:14 A AMAT-I1-•", _ -.=—— Right-Suite®Universal 2021 21.0.05 RSU29066 Page 1 ACCA ...nts\WrightsoftHVAC\8005BanyonStPSLProp.rup Calc=MJ8 Front Door faces:N TableReturn Branch Detail Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FIR (fpm) (in) (in) Opening(in) Matl Trunk rb2 Ox0 202 133 80.7 0.285 579 8.0 Ox 0 VIFx rt1 rb3 Ox0 155 157 87.2 0.264 586 7.0 Ox 0 VIFx rt1 rb1 Ox 0 234 210 45.3 0.508 529 9.0 Ox 0 VIFx rb8 Ox0 809 900 82.3 0.280 510 18.0 Ox 0 VIFx rt1 TableReturn Trunk Detail Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FIR (fpm) (in) (in) Material Trunk rt1 PeakAVF 1166 1190 0.264 673 1&0 0 x 0 VinlFlx Bolditalic values have been manually overridden wrightsoft® 2021-Mar-3013:21:14 A AMAT-I1-•", _ -.=—— Right-Sute®UNversal2021 21.0.05 RSU29066 Page 2 ACCA ...rts\WrightsoftHVAC\8005BaryonStPSLProp.rup Calc=MJ8 Front Door faces:N Manual S Compliance Report Job: 1448 +� wrightsoft° p p Date: 3/29/2021 House By: Chris Bateman Air Calcs, LLC 7550 Hidden Hammock Ln,Vero Beach,FL32966 Phone:772.800.8413 Email:vickilyme@aircalcs.com Project Information For: Bolinski Residence,Air Conditioning Unlimited 8005 Banyon Ste,Fort Pierce,FL 34951 Cooling Equipment Design Conditions Outdoor design DB: 90.4°F Sensible gain: 23496 Btuh Entering coil DB: 77.0°F Outdoor design WB: 77.4°F Latent gain: 7429 Btuh Entering coil WB: 64.2°F Indoor design DB: 75.0°F Total gain: 30926 Btuh Indoor RH: 50% Estimated airflow: 1167 cfm Manufacturer's Performance Data at Actual Design Conditions Equipmenttype: SplitAC Manufacturer: Goodman Mfg. Model: GSX16S361A+ASPT47D14A Actual airflow: 1167 cfm Sensible capacity: 24500 Btuh 104%of load Latent capacity: 10500 Btuh 141%of load Total capacity: 35000 Btuh 113%of load SHR: 70% Heating Equipment Design Conditions Outdoor design DB: 41.0°F Heat loss: 26243 Btuh Entering coil DB: 67.6°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipmenttype: Elecstrip Manufacturer: Model: Actual airflow: 1167 cfm Output capacity: 7.7 kW 101%of load Temp.rise: 50 °F Meets all requirements ofACCA Manual S. wrightsoft, 2021-Mar-30 13:21:14 A II,-=Io-•", _ -.=—— Right-Sute®Universal 2021 21.0.05 RSU29066 Page 1 ACCA nts\Wrightsoft HVAC\8005 Banyon St PSL Prop.rup Calc=MJ8 Front Door faces:N N Level 1 120 CFM 30'Wx32'H 6"Dud 6"Exhaust Vent 3C1'W x Sz'H 6" 29'Wx66'H4„ Cafe 50 CFM 10 6 `� 80"Wx8'B'H 12x12 4"Dud71VMW� y2044"ExhaustVerrt W Clst 7„ 4' y 3C1'Wx52'H Master Bed GreatRoom 10x 10 10x 10 Kitchen 8X8 7" 8x8 P 161cfm m�161ch T 84 ch 8„ 30'Wx32'H 5" F y 7" W 12x12 y 5� P 237cfrn 16 x 16 3'0'Wx52'H 4„234 cfin 8" 5 / Laundry 7' Hall 5" ® 10x6 1 8x4 1 900 cfm 2x8 30x18 �n 8x8 70 cfrn 38ch F 4„ /157 cfin 59 cfin 20'Wx42'H Sx Foyer 5„ 16" 491 Hers 10", His 9" 18.1 4,� 80CFM Gara 10x6 Bath 4"Dud 61 c6n 4"ExhaustVenl HNV / 12x 12 1r 7" 202 cfm DUCTS IN THE GARAGEAND y 12x8 DUCTS PENETRATING THE Bed 3 12x 12 202 chn WALLSORCEILINGS 30'Wx1 'H 157ch SEPARATING THE DWELLING Bed 2 FROM 30'Wx6TH 30'Wz52'H 30' x52'H THE GARAGE SHALLBE 307Wx1'3"H 30'Wxi'3"H CONSTRUCTED OFA MINIMUM NO. 26 GAGE(0.48 MM)SHEET STEEL,1 INCH MINIMUM RIGID NONMETALLIC CLASS 0 OR CLASS 1 DUCT BOARD,OR 3V'W x Sz'H OTHERAPPROVED MATERAL AND SHALL HAVE NO OPENINGS INTOTH EGARAGE Job#: 1448 Air Callas, LLC Scale: 1 : 128 Performed by Chris Bateman for: Page 1 Bolinski Residence 7550 Hidden Hammock Ln Right-Suite@ Universal 2021 8005 Banyon Ste Vero Beach, FL 32966 21.0.05 RSU29066 Fort Pierce, FL 34951 Phone:772.800.8413 2021-Mar-3013:21:23 vickilynne@aircalcs.com HVAC\8005 Banyon St PSLProp.rup