HomeMy WebLinkAboutApplication For Construction Permit�STATE OF FLORIDA DEPARTMENT OF HEALTH -a- ONSITE SEWAGE TREATMENT AND DISPOSAL l' SYSTEM APPLICATION FOR CONSTRUCTION PERMIT APPLICATION FOR: PERMIT- NO. 5�-SF-Al LL S,9 DATE PAID: �® FEE PAID: RECEIPT #: [,(] New System [ ] Existing System [ ] Holding Tank [ ] Innovative [ ] Repair [ ] Abandonment [ ] Temporary [ ] APPLICANT: Port St. Lucie Properties, Inc.. 172P &2-& P 3176 - AGENT: Alexander J. Piazza PSM, Inc. TELEPHONE: 772-340-7770 MAILING ADDRESS: 619 SW Biltmore Street, Port St. Lucie, Florida 34983 TO BE COMPLETED BY APPLICANT OR APPLICANT'S AUTHORIZED AGENT. SYSTEMS MUST BE CONSTRUCTED BY A PERSON LICENSED PURSUANT TO 489.105(3)(m) OR 489.552, FLORIDA STATUTES. IT IS THE APPLICANT'S RESPONSIBILITY TO PROVIDE DOCUMENTATION OF THE DATE THE LOT -WAS CREATED OR PLATTED (MM/DD/YY) IF REQUESTING CONSIDERATION OF STATUTORY GRANDFATHER PROVISIONS. PROPERTY INFORMATION LOT: 5 BLOCK: 71 SUBDIVISION: PROPERTY ID # : 3402-609-0683-000-3 Indian River Estates Unit 8 PLATTED: 1956 ZONING: R I/M OR EQUIVALENT: [ No ] PROPERTY SIZE: 0.230 ACRES WATER SUPPLY: [Jol PRIVATE PUBLIC [V]<=2000GPD [ 1>2000GPD IS SEWER AVAILABLE AS PER 381.0065 FS? [ No ] DISTANCE TO SEWER: FT PROPERTY ADDRESS: 5912 Sunset Boulevard, Fort Pierce, FL 34982 DIRECTIONS TO PROPERTY: SEE MAP BUILDING INFORMATION Unit Type of No Establishment 1 RESIDENCE 2 3 4 [V ] RESIDENTIAL [ ] COMMERCIAL No. of Building Commercial/Institutional System Design Bedrooms Area Sqft Table 1, Chapter 64E-6, FAC 3 1,233 Floor/Equipment Drains Other (Specify) GARBAGE GRINDERS / DISPOSALS SIGNATURE: Alexander J Piazza o;yfixny,ipW ny nk...dnJ Pi— ,, US-mUmQ1i-',uu-AOW10000000]7276(Z2F43000167rA, rn-Al—de 2 WW 20200311ssxu -UW DATE: 8-31-20 DH 4015, 08/09 (Obsoletes previous editions which may not be used) Incorporated 64E-6.001, FAC Page 1 of 4 STATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM SITE EVALUATION AND SYSTEM SPECIFICATION APPLICANT: Port St. Lucie Properties, Inc CONTRACTOR / AGENT: Alexander J. Piazza PSM, Inc v LOT: 5 BLOCK: 71 SUBDIVISION: Indian River Estates ID#: 3402-609-0683-000-3 APPLICATION # AP1583420 PERMIT # 56-SF-2184289 DOCUMENT # SE1454770 TO BE COMPLETED BY ENGINEER, HEALTH DEPARTMENT EMPLOYEE, OR OTHER QUALIFIED PERSON. ENGINEERS MUST PROVIDE REGISTRATION NUMBER AND SIGN AND SEAL EACH PAGE OF SUBMITTAL. COMPLETE ALL ITEMS. PROPERTY SIZE CONFORMS TO SITE PLAN: [X]YES [ ]NO NET USABLE AREA AVAILABLE: 0.23 ACRES TOTAL ESTIMATED SEWAGE FLOW: 300 GALLONS PER DAY [ RESIDENCES-TABLEI / OTHER -TABLE 2 ] AUTHORIZED SEWAGE FLOW: 575.01 GALLONS PER DAY [ 1500 GPD/ACRE OR 2500 GPD/ACRE ] UNOBSTRUCTED AREA AVAILABLE: 750.00 SQFT UNOBSTRUCTED AREA REQUIRED: 750.00 SQFT BENCHMARK/REFERENCE POINT LOCATION: Site BM, pa ELEVATION OF PROPOSED SYSTEM SITE 2.00 [ "X" CL of rd near center of / FT ] [I ABOVE I/ BELOW ] BENCHMARK/REFERENCE POINT THE MINIMUM SETBACK WHICH CAN BE MAINTAINED FROM THE PROPOSED SYSTEM TO THE FOLLOWING FEATURES SURFACE WATER: FT DITCHES/SWALES: 65 FT NORMALLY WET: [ ]YES [ ]NO WELLS: PUBLIC: FT LIMITED USE: FT PRIVATE: FT NON -POTABLE: 50 FT BUILDING FOUNDATIONS: 5 FT PROPERTY LINES: 5 FT POTABLE WATER LINES: 48 FT SITE SUBJECT TO FREQUENT FLOODING? [ ]YES [X]NO 10 YEAR FLOODING? [ ]YES [X]N O] 10 YEAR FLOOD ELEVATION FOR SITE: FT[ MSL / NGVD ] SITE ELEVATION: FT [ MSL / NGVD SOIL PROFILE INFORMATION SITE 1 ROTL PRAFTT.F. TN7nRMATTr]N ATW 9 USDA SOIL SERIES: Munsell #/Color Texture Depth 1 OYR 3/1 Loamy Sand 0 To 9 1 OYR 5/1 Sand 9 To 29 1 OYR 6/1 Sand 17 To 38 1 OYR 2/2 Spodic Material 38 To 49 HOLE CAVING Refusal 49 To 72 USDA SOIL SERIES: Munsell #/Color Texture Depth 10YR 3/2 Loamy Sand 0 To 8 10YR 5/1 Sand 8 To 30 10YR 6/1 Sand 18 To 40 10YR 2/1 Spodic Material 40 To 50 HOLE CAVING Refusal 50 To 72 OBSERVED WATER TABLE: 29.00 INCHES [ ABOVE / BELOW ] EXISTING GRADE TYPE: [ PERCHED / APPARENT ] ESTIMATED WET SEASON WATER TABLE ELEVATION: 17 INCHES [ ABOVE / BELOW ] EXISTING GRADE HIGH WATER TABLE VEGETATION: [ ]YES EX ]NO MOTTLING: [X]YES [ ]NO DEPTH: 17.00 INCHES SOIL TEXTURE/LOADING RATE FOR SYSTEM SIZING: Loamy Sand/0.60 DEPTH OF EXCAVATION: INCHES DRAINFIEMD CONFIGURATION: [ ] TRENCH [X ] BED [ ] OTHER (SPECIFY) r REMARKS/ADDITIONAL CRITERIA -71 >WT determined using USDA WSS and soil borings. (R6/1 stripping in 10YR5/1 matrix >10% with diffuse boundaries starting at 17" in SB1. 1 2" above BM. SB2 3" above BM. zi SITE EVALUATED BY: Ingram, Bria?Yltle: Environmental Specialist II) (ENVIRONMENTAL HEALTH) DA 4015, 06/09 (Obsoletes previous editions which may not be used) Incorporated: 64E-6.001, FAC DATE: 12/28/2020 Page 3 of 4 AP1583420 EID2184289 v 1.0.2 E STATE OF FLORIDA PERMIT DEPARTMENT OF HEALTH L �b3 ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM ;��/�._6A• SITE EVALUATION AND SYSTEM SPECIFICATIONS � b'.Z ai•M_ APPLICANT: Port St. Lucie Properties, Inc. AGENT: Alexander J. Piazza PSM, Inc. ti LOT: 5 BLOCK: 71 SUBDIVISION: Indian River Estates Unit 8 PROPERTY ID # : 3402-609-0683-000-3 [ Tax ID Number TO BE COMPLETED BY ENGINEER, HEALTH DEPARTMENT EMPLOYEE,OR OTHER QUALIFIED PERSON. ENGINEERS MUST PROVIDE REGISTRATION NUMBER AND SIGN AND SEAL EACH PAGE OF SUBMITTAL. COMPLETE ALL ITEMS. PROPERTY SIZE CONFORMS TO SITE PLAN: [✓] YES [ ] NO NET USABLE AREA AVAILABLE: 0.230 TOTAL ESTIMATED SEWAGE FLOW: 500 GALLONS PER DAY [RESIDENCES -TABLE POTHER-TABLE2 AUTHORIZED SEWAGE FLOW: GALLONS PER DAY [ 1500 GPD/ACRE OR 2500 GPD/ACRE UNOBSTRUCTED AREA AVAILABLE: 750 SQFT UNOBSTRUCTED AREA REQUIRED: 750 ACRES ] ] SQFT BENCHMARK/REFERENCE POINT LOCATION: ELEVATION OF PROPOSED SYSTEM SITE IS34 [INCHES/FT ] [ABOVE/BELOW'] BENCHMARK/REFERENCE POINT THE MINIMUM SETBACK WHICH CAN BE MAINTAINED FROM THE PROPOSED SYSTEM TO THE FOLLOWING FEATURES SURFACE WATER:100 FT DITCHES/SWALES:15 FT NORMALLY WET? [ YES [✓] NO WELLS: PUBLIC:200 FT LIMITED USE:100 FT PRIVATE:75 FT NON—POTABLE:100 FT BUILDING FOUNDATIONS:5 FT PROPERTY LINES:10 FT POTABLE WATER LINES: FT SITE SUBJECT TO FREQUENT FLOODING: [ ] YES [✓] NO 10 YEAR FLOODING? [ ] YES [✓] NO 10 YEAR FLOOD ELEVATION FOR SITE: FT MSL/NGVD SITE ELEVATION: FT MSL/NGVD SOIL PROFILE INFORMATION SITE 1 MUNSELL #/COLOR TEXTURE DEPTH TO TO TO TO TO TO TO TO TO USDA SOIL SERIES: SOIL PROFILE INFORMATION SITE 2 MUNSELL #/COLOR TEXTURE DEPTH TO TO TO TO TO TO TO TO TO USDA SOIL SERIES: OBSERVED WATER TABLE:40+ INCHES [BELOW T] EXISTING GRADE. TYPE:[ PERCHED/ APPARENT ] ESTIMATED WET SEASON WATER TABLE ELEVATION: INCHES ABOVE BELOW ] EXISTING GRADE HIGH WATER TABLE VEGETATION: [ ] YES [ ] NO MOTTLING: [ ] YES [ ] NO DEPTH: INCHES SOIL TEXTURE/LOADING RATE FOR SYSTEM SIZING: DRAINFIELD CONFIGURATION: [,(] TRENCH [ ] BED REMARKS/ADDITIONAL CRITERIA: DEPTH OF EXCAVATION: [ ] OTHER (SPECIFY) a Alexander J Piazza or%Rus o=w�irin�led,ou no SITE EVALUATED BY • Dale.ne020de2020A83 15-51 1558:55 -04'00' INCHES DATE: 8-31-20 DH 4015, 12/11 (Obsoletes previous editions which may not be used) Incorporated: 64E-6.001, FAC Page 3 of 4 r APPLICANT'S NAIME: Port St. Lucie Properties, Inc. LEGAL DESCRIPTION: Lot 5, Block 71, Indian River Estates Unit 8 (PB 10, PG 73) �(\wry �j.`M/��c .. .:. ....T/x�;(,(�F�{(�//..t'/�{.�f� 1.1E i:iY Wy L1:/'S►rC, l..E l'1f. J:�•' 1�', . . ... - . _ ..e .. _... ..... _ ..µ. .. ......, ... I certify that there are no potable private wells within 75 feet of the available area for the proposed septic system; that there are no non -potable wells within 50 feet of the available area for the proposed septic system,. that there are no wells within 25 feet of a pesticide -treated building foundation; that there are no public wells that serve less than 25 people or less than- 15 homes or businesses within.100 feet of the proposed septic system, that there are no public wells that serve more than- 25 people or more than 15 homes or businesses within 200 feet of the proposed septic system, that the water line from the- water meter or, well to the structure is at least 10 feet from the available area for the proposed septic system unless the plans show the line to be double sleeved,that there is not a gravity sewer line, low pressure sewer line or vacuum sewage line in a public easement or right -of --way that abuts the property, that there are no lakes, streams, wetlands, or.surface water within 75 feet of the available area for the proposed septic system unless theproperty was created prior to 1972, that the septic system is proposed on the.side of the lot farthest from surface water, that all private wells, septic systems and surface .water on adjacent or contiguous land within 75 feet of the applicant's lot are shown on -the site plan, that all public wells within 200 feet of the applicant's lot are shown on the site plan, and that the location of building or residences, swimming pools, recorded easements, paved areas or driveways, sidewalks, the general slope of the property, filled areas, drainage features, and -surface waters such as lakes, ponds, streams, canals, or wetlands are shown on the applicants lot. The natural grade elevation in. the area of the. proposed septic system and. the benchmark must be shown on the site plan. Please. locate the benchmark within 200 feet of the proposed septic system. NOTE: MUST BE CERTIFIED BY A FLORIDA REGISTERED SURVEYOR -OR ENGINEER. D1g1WF/s1gr" by AM—WJ Plaw s,=17Ff7000167FqiAIexander J Piazza =UUwHl`ecd t CERTIFIED BY: Wte:202MM"15:5839.04°" FLORIDA PROFESSIONAL NO.: DATE: 08/31 /20 JOB WC . 6330 20-5905 docs/ forms/septics/SepticApppPage207 Property Card '56-5F' 2,1 q ni Page 1 of 1 Michelle Franklin, CFA -- Saint Lucie County Property Appraiser -- All rights reserved. Property Identification Site Address: 5912 SUNSET Parcel ID: 3402-609-0683- Account #: 38166 Sec/Town/Range: BLVD 000-3 11/36S/40E Map ID: 34/11 S Zoning: RS-4 Count Use Type: 0000 Jurisdiction: Saint Lucie County Ownership Legal Description William C Shockley Jr INDIAN RIVER ESTATES-UNIT-08- BLK 71 LOT 5 (MAP 378 NW Stratford LN 34/11S) Port St Lucie, FL 34983 Current Values Historical Values 3-year Just/Market: $14,400 Assessed: $8,765 Year Just/Market Assessed Exemptions Taxable Exemptions: $0 Taxable: $8,765 2020 $14,400 $8,765 $0 $8,765 2019 $11,700 $7,969 $0 $7,969 2018 $10,000 $7,245 $0 $7,245 Date 09-03-2020 09-28-2007 03-11-2004 View: Year Built: N/A Primary Wall: Bedrooms: 0 Full Baths: 0 Half Baths: 0 Sale History Book/Page Sale Code Deed Grantor 4472 / 2549 0001 WD GOLIveia Nelio R 2887 / 1689 XX00 WD Cass Rory 1917 / 1141 XX00 WD Diamonds and Passion Ent Inc Primary Building Information Finished Area of this building: 0 SF Gross Sketched Area: 0 SF Exterior Data Price $27,000 $22,500 $24,000 Roof Cover: Roof Structure: Building Type: Frame: Grade: Effective Year: N/A Story Height: No. Units: 0 Secondary Wall: Interior Data A/C %: 0% Electric: Primary Int Wall: Heated %: N/A% Heat Type: Avg Hgt/Floor: 0 Sprinkled %: 0% Heat Fuel: Primary Floors: Total Areas Finished/Under Air 0 (SF): Gross Sketched Area 0 (SF): Land Size (acres): 0.23 Land Size (SF): 10,000 Total Building Count: 1 Special Features and Yard Items Type Qty Units Year Blt r All information is believed to be correct at this time, but is subject to change and is provided without any warranty. Copyright 2020 Saint Lucie County Property Appraiser. All rights reserved. https://www.pasic.org/RECard/ 10/8/2020 7/30/2020 5912 Sunset Blvd - Google Maps pS 5 912 Sunset Blvd U. fi� F U"dini, SI Lucie Flals,-Isi V1, and tt..11,11 nlr 0 ell 5912 Sun, e' I Boulevai S,p M P:L!y. 4� OLSIC'..- Rao -,,_Pwr Dwc"WQ, ("d CIIIN, sz.jd, Go gle Map data @2020 200 ft L---A hftps://www.google.com/maps/place/5912+Sunset+Blvd,+Fort+Pierce,+FL+349821@27.3568435,-80.3125661,17z/data=!4m5!3m4!isOx88deefai3Olcbda9:Oxcb42023049fO448b!8m2Vl.M&5714d-... 1/2 Soil Map —St. Lucie County, Florida 27° 21'23'N 27' 21' 21' N 566760 5581�J0 56M 568810 968820 568630 5mm 5� 3 .. b a, Map Smle: 1:558 if printed on A larl pe (11" x 8.5') sheet '" Metels N 0 5 10 20 30 Feet 0 25 50 100 150 Map pnmjeciion: Web Men-ahx Cmerwordinates: WGS84 Edge tics: UTM Zone 17N WGS84 USDA Natural Resources Web Soil Survey Conservation Service National Cooperative Soil Survey i r' a1r �ak1�x' � f ty W a S • L>' , � pgp4 1N• ye yam, ] •3' Ya,7F GC` I 1 11/16/2020 Page 1 of 3 Soil Map --St. Lucie County, Florida Map Unit Legend Map Unit Symbol: Map Unit Name '. Acres in AO1 Percent of AO1 . 21 Lawnwood and Myakka sands 0.9 69.5% 50 Waveland and Immokalee fine sands 0.4 30.5% Totals for Area of Interest 1.3 100.0% Natural Resources Web Soil Survey 11/16/2020 Conservation Service National Cooperative Soil Survey Page 3 of 3