BLOWER DOOR TEST FORM
House Infiltration Test certification
Prescriptive and Performance Method
Permit #96
2oo
Job Address: _ f 1— / 3 14% V IF 4
r
Construction: A'New Construction — Complete �
House infiltration Test Resull
CAM (50) = IS-7 7
SLC Climate Zone 2
Volume = �7 / ( ( � (?""
ACH (50) = CFM (SO) x 50 / Volume = �►
Passing results must be & ACH (50) or less
FBC, Energy
Test Da:
-OW 0 �2 ao? /
01
-O'r- C --p
=r 3 y9�o2
} Existing — After Addition
Nle hanrcal Ventilation required less than 3 ACH
( Pass ( )Fail
The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per
hour in Climate Zone 1, 2 and 3 air changes per hourin Climate Zones 3 through 8. Testing shall be conducted with a
blower door at a pressure of 0.2 inches w, g, (50 Pascals). Testing shall be conducted by either individuals as defined in
Section 553.993(S) or (7), Florida Statutes or individuals licensed asset forth in Section 489.105 (3)(f), (g) or (1) or an
approved third party. A written report of the results of the test Shall be signed by the party conducting the test and
provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building
thermal envelope.
FBC, Residential
Where the air infiltration rate of a dwelling unit is less than 3 air changes per hour when tested with a blower door at a
Pressure of 0.2 inch w. c. (50 Pad in accordance with Section R402.4.1.2 of the Florida Budding Code, Energy Conservation
the dwelling unit shall be provided with whole -house mechanical ventilation in accordance with Section M1507.3,
Testin,& Company
Company Name. Pro -Duct Services
Address: 1915 Rio Vista Dr. Fort Pierce,Fl. 34949
hereby certify that the above House Infiltration results demonstrate compliance with FBC Energy Conservation
requirements in accordance with Section R402.4.1.2 Climate Zone 2.
Signature:
Printed Name: Michael Faurot
License/Certification #: 5059122