HomeMy WebLinkAbouthealth departmentSTATE OF FLORIDA
DEPARTMENT OF HEALTH
ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM
CONSTRUCTION INSPECTION AND FINAL APPROVAL
PERMIT #:
DATE PAID:
FEE PAID:
RECEIPT #:
660.00
56-SF-1974922
DOCUMENT #:FI1750124
AP1423850APPLICATION #:
56-PID-4015000
07/16/2019
LOT:
ID#:
BLOCK:
SUBDIVISION:
APPLICANT:John Sweeney
AGENT:
PROPERTY ADDRESS:5281 Tree Top Trl Fort Pierce, FL 34951
CHECKED [X] ITEMS ARE NOT IN COMPLIANCE WITH STATUTE OR RULE AND MUST BE CORRECTED.
[01] TANK SIZE[][1]1090.00 [2]483.00
[02] TANK MATERIAL[]Polypropylene
[03] OUTLET DEVICE[]
[04] MULTI-CHAMBERED[][Y ]N/
[05] OUTLET FILTER[]
[06] LEGEND[]
[07] WATERTIGHT[]
[08] LEVEL[]
[09] DEPTH TO LID[]
TANK INSTALLATION
[27] SURFACE WATER[]
SETBACKS
FT
[28] DITCHES[]36 FT
[29] PRIVATE WELLS[]95 FT
[30] PUBLIC WELLS[]FT
[31] IRRIGATION WELLS[]FT
[32] POTABLE WATER []64 FT
[33] BUILDING FOUNDATIONS[]9 FT
[34] PROPERTY LINES[]36 FT
[35] OTHER[]FT
[10] AREA[][1]509 [2]
[11] DISTRIBUTION[]
[12] NUMBER OF DRAINLINES[]
[13] DRAINLINE SEPARATION[]
[15] DEPTH OF COVER[]
[16] ELEVATION []
[17] SYSTEM LOCATION[]
[18] DOSING PUMPS[]
[19] AGGREGATE SIZE[]
DRAINFIELD INSTALLATION
SQFT
BOX HEADER X
[BELOW ]BMABOVE/21.00
[14] DRAINLINE SLOPE[]
1.00
[20] AGGREGATE EXCESSIVE FINES[]
[21] AGGREGATE DEPTH[]
[36] DRAINFIELD COVER[]
FILLED / MOUND SYSTEM
[37] SHOULDERS[]
[38] SLOPES[]
[39] STABILIZATION[]04/30/2021
[40] UNOBSTRUCTED AREA[]
ADDITIONAL INFORMATION
[41] STORMWATER RUNOFF[]
[42] ALARMS[]
[43] MAINTENANCE AGREEMENT[]
[44] BUILDING AREA[]
[45] LOCATION CONFORMS WITH SITE PLAN[]
[46] FINAL SITE GRADING[]
[47] CONTRACTOR[]Mike Stuhr (Ashton)
[48] OTHER[]INFILTRATOR Quick4 Plus EQ36 LP
[49] TANK PUMPED[]
ABANDONMENT
[50] TANK CRUSHED & FILLED[]
[22] FILL AMOUNT[]
FILL / EXCAVATION MATERIAL
[23] FILL TEXTURE[]
[24] EXCAVATION DEPTH[]
[25] AREA REPLACED[]
[26] REPLACEMENT MATERIAL[]
Polylok PL-68
1.2.
1.2.
70-143-54SC4
5.00
70-143-11DC4
1407-343-0005-000-1
Comments are on page 2.Comments:
CONSTRUCTION []:/CHD DATE:
DISAPPROVED
St. Lucie 03/12/2021APPROVED
Environmental Specialist II Nicole Montanez (Florida Department of He
FINAL SYSTEM []:/CHD DATE:DISAPPROVED St. Lucie 04/30/2021
Environmental Specialist III Brian J Ingram (ENVIRONMENTAL HEALTH)
APPROVED
(Explanation of Violations on following page)
EH Database v 1.0.1 AP1423850 EID1974922
Page 2 of 3
DH 4016, 08/09 (Obsoletes all previous editions which may not be used)
Incorporated: 64E-6.003, FAC
STATE OF FLORIDA
DEPARTMENT OF HEALTH
ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM
CONSTRUCTION INSPECTION AND FINAL APPROVAL
PERMIT #:
DATE PAID:
FEE PAID:
RECEIPT #:
660.00
56-SF-1974922
DOCUMENT #:FI1750124
AP1423850APPLICATION #:
56-PID-4015000
07/16/2019
Violation Number Comment
The system is sized for 3 bedrooms with a maximum occupancy of 6 persons (2 per bedroom), for a total estimated flow of
300 gpd.
New ST, DT, Liberty 1/3 HP pump, and 5x9 long BED DF installed. Gutters will need to be installed for stormwater runoff
requirement. System ok to cover. Contractor notified by phone. Needs final inspection for gutters, alarm system and to verify that
pump wires exit DT in conduit through the riser wall and final site grading.
Final system approved. contractor emailed final approval.
Comments
EH Database v 1.0.1 AP1423850 EID1974922
Page 2 of 3
DH 4016, 08/09 (Obsoletes all previous editions which may not be used)
Incorporated: 64E-6.003, FAC