in MIAAMI-DADE COUNTY
PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, boom 208
BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamiaaae.gov/economy
Worthouse, Inc.
3100 Arapahoe Ave Suite 104
Boulder, CO 80303-1050
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product
or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the
manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use
of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is
determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements .
of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Supre, Dura, Eura and Ulta Roofing Panels
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA consists of pages I through 15.
The submitted documentation was reviewed by Alex Tigera.
NOA No.: 17-0221.05
Expiration Date: 04/12/23
Approval Date: 04/12/18
Page 1 of 15
ROOFING SYSTEM APPROVAL:
Category:
Roofing
Sub -Category:
Metal, Panels
Material:
Steel
Deck Type:
Wood
Maximum Design Pressure:
-157.5 psf
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED By APPLICANT:
Test Product
Product Dimensions Specifications
Description
Supre 46.9" x 13.8"
TAS 125 Painted steel preformed panels.
45.3" x 13.8" (installed coverage)
Thickness 26 ga.
Min. 46 ksi
Dura 47.0" x 13,8"
TAS 125 Painted steel preformed panels.
45.3" x 13.8" (installed coverage)
Thickness 26 ga.
Min, 46 ksi
Pura 46.4" x 13.8"
TAS 125 Painted steel preformed panels.
43.3" x 13.8" (installed coverage)
Thickness 26 ga.
Min. 46 ksi
Ulta 46.8" x 13.8"
TAS 125 Painted steel preformed panels,
44.9" x 13.8" (installed coverage)
Thickness 26 ga.
Min.46 ksi
MANUFACTURING LOCATION
1. Plock, Masovian, Poland
EVIDENCE SUBMITTED:
Test Agency Test Identifier
Test Name/Reuort Date
PRI Construction Materials BDMT-001-02-01
TAS 125 / UL 1897/ UL 580 11/11/16
Technologies, LLC BDMT-00 1-02-02
TAS 125 / UL 1897/ UL 580 11/11/16
BDMT-002-02-01
TAS 100 12/02/16
BDMT-004-02-01
TAS 100 12/05/16
BDMT-005-02-01
ASTM G 155 12/02/16
BDMT-006-02-01
ASTM B 117 11/02/16
MM= NOA No.: 17-0221,05
MLAMI-DADE COUNTY
IIIURTSM) Expiration Date: 04/12/23
Approval Date-, 04/12/18
Page 2 of 15
APPROVED ASSEMBLIES:
System 1: Supre, Dura, Eura and Ulta Panels
Deck Type: Wood, Non -insulated
Deck Description: New Construction "/32" or greater plywood or wood plank, or Re -roof "/32" or greater
plywood or wood plank.
Slope Range: 2:12 or greater
Maximum Uplift See Fastening Options Below
Pressure•
Deck Attachment: In accordance with Applicable Building Code, but in no case shall it be less than #8d x 2-
1/2" long ring -shank nails spaced 6"o.c. In reroofing, where the deck is less than "/32"
thick (minimum "/32"), the above attachment method must be in addition to existing
attachment.
Underlayment: Minimum underlayment shall be an ASTM D 226 Type H installed with a minimum 4"
side -laps and 6" end -laps, Underlayment shall be fastened with corrosion resistant tin -caps
and lY4" annular ring -shank nails, spaced 6" o.c. at all laps and two staggered rows 12" o.c.
in the field of the roll. Or, any Miami -Dade County Product Control Approved
underlayment having a current NOA.
Fire Barrier Board: Any approved fire barrier having a current NOA. Refer to a current fire directory listing for
fire ratings of this roofing system assembly as well as the location of the fire barrier within
the assembly. See Limitation 4 1.
Valleys: 23" wide valley metal attached with 4.8mm x 35mm HWH screws with 14mm O.D. sealing
washers attached 14" o.c. along the valley edges. Edges of valley shall be seated to the
underlayment with a continuous 1/4" bead of an approved polyurethane roof sealant. Valley
construction shall be in compliance with Roofing Application Standard RAS 133 and with
Worthouse, Inc current published installation instructions.
Metal Panels and Install the panel and accessories in compliance with Worthouse, Inc. current, published
Accessories: installation instructions and details. Flashings, penetrations, valley construction and other
details shall be constructed in compliance with the minimum requirements provided in
Roofing Application Standard RAS 133.
First Row: Install a 2" x 2" batten over the drip edge and secured to the deck 12" o.c. with 410 x 3-1/2"
deck screws. Place 2-3/4" x 6" x Yz" flashing over the batten with 6" face extending down
the batten over the drip edge. A Y2" bead of approved polyurethane roof sealant shall be
placed along the top of the flashing at the windward edge. First panels shall be placed over
the flashing into the bead of sealant and secured through to the batten with two (2) 4.8mm x
35min HWH screws with 14 mm (outside diameter) sealing washers in each pan.
NOA No.: 17-0221.05
Expiration Date: 04/12/23
Approval Date: 04/12/18
Page 3 of 15
Field Condition: 4.8mm x 35mm HWH screws with 14 mm D.D. sealing washers attached at a rate of 1110
screws per panel" for Supre, Dura and Ulta Panels or "12 screws per panel" for Eura
Panel (see Appendix A for fastening patterns); Panel laps stitched with 4.8mm x 19mm
HWH screws with l4mm O.D. sealing washers at the preformed locations; Fasteners shall
penetrate the deck a minimum 3/8-inch and shall be corrosion resistant.
Maximum Design -67.5 psf.
Pressure for Field
Condition:
Perimeter and Corner 4.8mm x 35mm HWH screws with 14 mm O.D. sealing washers attached at a rate of "20
Condition: screws per panel" for Supre, Dura and Ulta Panel or 1124 screws per panel" for Eura
Panel (see Appendix A for fastening patterns), Panel laps stitched with 4.8mm x 19mm
HWH screws with l4mm O.D. sealing washers at the preformed locations. Fasteners shall
penetrate the deck a minimum 3/8-inch and shall be corrosion resistant,
Maximum Design -97.5 psE
Pressure for Field
Condition:
M"I-DADE courarrNOA No.: 17-0221,05
Expiration Date: 04/12/23
Approval Date: 04/12/18
Page 4 of 15
System 2: Supre, Dura, Eura and Ulta Panels
Deck Type: Wood, Non -insulated
Deck Description: New Construction '9/32" or greater plywood or wood plank, or Re -roof 15/32" or greater
plywood or wood plank.
Slope Range: 2:12 or greater
Maximum Uplift See Fastening Options Below
Pressure:
Deck Attachment: In accordance with Applicable Building Code, but in no case shall it be less than #8d x 2-
1/2" long ring -shank nails spaced 6"o.c. In reroofing, where the deck is less than '1/32"
thick (minimum "/32"), the above attachment method must be in addition to existing
attachment,
Underlayment: Minimum underlayment shall be an ASTM D 226 Type 11 installed with a minimum 4"
side -laps and 6" end -laps. Underlayment shall be fastened with corrosion resistant tin -caps
and IV4" annular ring -shank nails, spaced 6" o.c. at all laps and two staggered rows 12" o.c.
in the field of the roll. Or, any Miami -Dade County Product Control Approved
underlayment having a current NOA,
Fire Barrier Board: Any approved fire barrier having a current NOA. Refer to a current fire directory listing for
fire ratings of this roofing system assembly as well as the location of the fire barrier within
the assembly. See Limitation # 1.
Valleys: 23" wide valley metal attached with 4.8mm x 35mm HW11 screws with 14mm O.D. sealing
washers attached 14" o.c. along the valley edges. Edges of valley shall be sealed to the
underlayment with a continuous %" bead of an approved polyurethane roof sealant. Valley
construction shall be in compliance with Roofing Application Standard RAS 133 and with
Worthouse, Inc current published installation instructions.
Counter Batten: Install minimum Ix4 No. 2 dimensional lumber laid maximum 24-inch o.c. over the
plywood deck trusses/rafters and perpendicular to the eave. Secure counter batten
simultaneously with batten as described below under Batten section.
Batten: Install minimum 2x4 No. 2 dimensional lumber installed 14" o.c, and perpendicular to the
counter batten. Two (2) 3.5" x #10 stainless steel deck screws were installed at each
batten/counter batten intersection.
Metal Panels and Install the panel and accessories incompliance with Worthouse, Inc. current, published
Accessories: installation instructions and details. Flashings, penetrations, valley construction and other
details shall be constructed in compliance with the minimum requirements provided in
Roofing Application Standard RAS 133.
First Row: Install a 2" x 2" batten over the drip edge and secured to the deck 12" o.c. with #10 x 3-1/2"
deck screws. Place 2-3/4" x 6" x V2" flashing over the batten with 6" face extending down
the batten over the drip edge. A Y2" bead of approved polyurethane roof sealant shall be
placed along the top of the flashing at the windward edge. First panels shall be placed over
the flashing into the bead of sealant and secured through to the batten with two (2) 4.8mm. x
35mm HWH screws with 14 mm (outside diameter) sealing washers in each pan.
MIAMI-11AADE COUNTY.NOA No.: 17-0221.05
Expiration Date: 04/12/23
Approval Date: 04/12/18
Page 5 of 15
Field Condition: 4.8mm x 35mm HWH screws with 14 mm O.D. sealing washers attached at a rate of 115
screws per panel" for Supre, Dura and Ulta Panels or 116 screws per panel" for Eura Panel
(see Appendix A for fastening patterns); Panel laps stitched with 4.8mm x l9mm HWH
screws with 14mm O.D. sealing washers at the preformed locations. Fasteners shall
penetrate the deck a minimum 3/8-inch and shall be corrosion resistant.
Maximum Design -116.25 psL
Pressure for Field
Condition:
Perimeter and Corner 4.8mm x 35min HWH screws with 14 min O.D. sealing washers attached at a rate of "10
Condition: screws per panel" for Supre, Dura and Uta Panels or "12 screws per panel" for Eura
Panel (see Appendix A for fastening patterns); Panel laps stitched with 4.8mm x 19mm
HWH screws with 14mm O.D. sealing washers at the preformed locations. Fasteners shall
penetrate the deck a minimum 3/8-inch and shall be corrosion resistant,
Maximum Design -157,5 pst
Pressure for Field
Condition:
KAMMADE COUNTYIS NOA No.; 17-0221,05
Expiration Date: 04/12/23
Approval Date: 04/12/18
Page 6 of 15
LIMITATIONS'.
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire
ratings of this product.
2. The maximum designed pressure listed herein shall be applicable to all roof pressure zones (i.e. field, perimeters,
and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced
pressure zones (i.e. perimeters, extended corners and corners).
3. All panels shall be permanently labeled with the manufacturer's name and/or logo, city and state of
manufacturing facility, and the following statement: "Miami -Dade County Product Control Approved" or with
the Miami -Dade County Product Control Seal as seen below.
Lr", 1 9 , a 0 lb
77A�PPRQVEDI
4. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 6 1 G20-3 of the Florida Administrative Code.
NOA No.: 17-0221.05
Expiration Date: 04/12/23
Approval Date: 04/12/18
Page 7 of 15
PROFILE DRAWINGS;
SUPPJE
APPROftEQ
1A
pi
!4 PO--
WOO
NOA No.: 17-0221.05
Expiration Date: 04/12/23
Approval Date: 04/12/18
Page 8 of 15
ULTA
NOA No.; 17-0221.05
Expiration Date: 04/12/23
Approval Date: 04/12/18
Page 9 of 15
FASTENING PATTERNS:
MIAWDADECOUNT-Y-M NOA No.; 17-0221.05
�091141149Expiration Date: 04/12/23
Approval Date: 04/12/18
Page 10 of 15
I Dura Panel Fastening Patterns
"5 screws per panel"
"10 screws per panel" with one (1) fastener at each indicated location.
"20 screws per panel" with two (2) fasteners at each indicated location (1-inch apart).
NOA No.: 17-0221.05
Expiration Date: 04/12/23
Approval Date: 04/12/18
Page 11 of 15
I Eura Panel Fastening Patterns ------ 7
"6 screws per panel"
"12 screws per panel" with one (1) fastener at each indicated location.
"24 screws per panel" with two (2) fasteners at each indicated location (1-inch
MtAMI-DADECO NOA No.: 17-0221.05
�UJVIIINII Expiration Date: 04/12/23
Approval Date: 04/12/18
Page 12 of 15
I Ulta Panel Fastening Patterns
"5 screws per panel"
"10 screws per panel" with one (1) fastener at each indicated location.
"20 screws per panel" with two (2) fasteners at each indicated location (1-inch apart).
MiAMI-DADE NOA No.: 17-0221.05
Expiration Date: 04/12/23
Approval Date: 04/12/18
Page 13 of 15
BattenlCounter Batten Fastening Patterns
4,8mm x 35mm HWH screws with 14mm Budmat Panel
O.D, sealing washer /
461111111111111111111iiiiiiiillllI
1 x 4 No. 2 SYP lumber
�3",u
Counter Batten Batten
Min. 15132 plywood deck Underlayment
#1t1 stainless steel deck
crew
Supre Panel to Panel Connection 1Z
Z-Ali
Dura Panel to Panel Connection
3
MLAMI-DADE COUNT
�Lluusyjglj
NOA No.: 17-0221.05
Expiration Date: 04/12/23
Approval Date: 04/12/18
Page 14 of 15
I Eura Panel to Panel Connection
I Ulta Panel to Panel Connection
51
al
0
END OF THIS ACCEPTANCE