HomeMy WebLinkAboutBEACH FRONT REALTYINSULATION CARD - DO NOT REMOVE
This form must be filled out and posted to comply with building code and FTC requirements.
Meets IRC Section N1101.4 requirements. Please post near electrical panel.
PLEASE ATTACH PRODUCT TECHNICAL DATA SHEET BEFORE POSTING
The following spray polyurethane foam insulation system(s) has been installed. Consult International Building Code, Section 2603 Foam
Plastic Insulation, International Residential Code (IRC) R314 Foam Plastics, or International Energy Conservation Code (IECC) Section
102 for specific requirements.
BASF Corporation Product(s) Installed:
Enertite Series Nominal 0.5 pcf Density (Open-cell Spray Polyurethane Foam)
Spraytite 178 Series 2.0 pcf Density (Closed-cell Spray Polyurethane Foam)
Spraytite 158 Series 2.0 pcf Density (Closed-cell Spray Polyurethane Foam)
This spray polyurethane foam insulation system has been installed in accordance with manufacturer’s processing
guidelines to provide a thermal resistance of (see R-value chart on reverse).
Area Insulated R-Value Thickness*
Attic Area R– @ inches
Sloped Ceilings R– @ inches
Walls (Where: ) R– @ inches
Walls (Where: ) R– @ inches
Floors (over an unheated crawl space) R– @ inches
Crawl Space Perimeter R– @ inches
Basement Interior Walls R– @ inches
Other (Where: ) R– @ inches
*Nominal thicknesses are representative of a field, spray-applied foam material.
List the code-required fire protection product(s) installed (List alternative materials or assemblies approved by 3rd party or ICC-ESR):
15-minute Thermal Barrier: To Be Covered with 1/2” Gypsum OR
Limited Access (No Storage) Ignition Barrier:
Jobsite Location: Date Installed:
Building Contractor:
Insulation Contractor: Phone:
Installed By:
Caution— No Hot Work - Polyurethane foam is combustible and should be treated as such. No welding
or cutting unless foam has been protected from accidental ignition by open flame.
BASF Corporation
1703 Crosspoint Avenue
Houston, TX 77054
Tel: 800-796-9743
www.spf.basf.com
INSULATION CARD - DO NOT REMOVE
INSULATION CARD - DO NOT REMOVE
Installed R-value Charts
Notes:
BASF Corporation
1703 Crosspoint Avenue
Houston, TX 77054
Tel: 800-796-9743
www.spf.basf.com
ISO 9001:2008 Accredited Facility - Houston, TX
INSULATION CARD - DO NOT REMOVE
JUNE 2016
What You Should Know About R-values
*These chart shows the R-value of this insulation. R means resistance to heat flow. The higher the R-value, the greater the insulating power. Compare insulation R-values before you buy.
There are other factors to consider. The amount of insulation you need depends mainly on the climate you live in. Also, your fuel savings from insulation will depend upon the climate,
the type and size of your house, the amount of insulation already in your house, and your fuel use patterns and family size. If you buy too much insulation, it will cost you more than what you’ll save on fuel.
To get the marked R-value, it is essential that this insulation be installed properly.
**U-factor is the inverse of R-value as represented in BTU /(h °F ft²). The lower the number, the better the performance of the material or assembly.
Using U-factor requires SPF is used within an Opaque Assembly. If used in a rafter assembly in a sealed attic approach, the SPF must be wrapped around all framing to ensure continuity.
ENERTITE IB 418
*** ATTIC and CRAWL SPACE assemblies (ICC-ES AC377, Appendix X)
·No Covering Required
· 12 inches (max) thickness in Wall
· 16 inches (max) thickness in Ceilings
· As a covering over ENERTITE NM
· 2 inches (min) covering 10 inches (max) ENERTITE NM in Walls
· 2 inches (min) covering 14 inches (max) ENERTITE NM in Ceilings
· No coating required when installed in accordance with the limitations described in Section X2.2 of ICC-ES Acceptance Criteria AC377 Approved November 2012 (Editorially corrected April 2013).