Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutDC315ESR-3702-1ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed
as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as
to any finding or other matter in this report, or as to any product covered by the report.
Copyright © 2021 ICC Evaluation Service, LLC. All rights reserved. Page 1 of 13
ICC-ES Evaluation Report ESR-3702
Reissued July 2021
This report is subject to renewal July 2023.
www.icc-es.org | (800) 423-6587 | (562) 699-0543 A Subsidiary of the International Code Council ®
DIVISION: 09 00 00—FINISHES
Section: 09 96 43—Fire-Retardant Coatings
REPORT HOLDER:
INTERNATIONAL FIREPROOF TECHNOLOGY INC.
EVALUATION SUBJECT:
DC315 INTUMESCENT COATING
1.0 EVALUATION SCOPE
Compliance with the following codes:
2018, 2015, 2012, 2009 and 2006 International Building
Code® (IBC)
2018, 2015, 2012, 2009 and 2006 International
Residential Code® (IRC)
Properties evaluated:
Application without a prescriptive thermal barrier
Application without a prescriptive ignition barrier
Physical properties
Surface burning characteristics
Water vapor transmission
Exterior walls in Types I through IV construction
2.0 USES
DC315 is a liquid-applied coating intended for application
over the surface of spray-applied foam plastic insulation
complying with ICC-ES Acceptance Criteria for Spray-
applied Foam Plastic Insulation (AC377). The coated
assembly may be left exposed to the interior of the building
without the application of a code-prescribed thermal barrier
when installed as described in Section 4.2 of this report. The
DC315 coating may be used in attic and crawl spaces as
described in Section 4.3 of this report. See Section 4.4 for
use in exterior walls of Type I, II, III and IV construction.
3.0 DESCRIPTION
3.1 General:
DC315 is a single-component, water-based, liquid-applied
intumescent coating and are available in white, ice gray,
dark gray and charcoal black. The coating is supplied in
5-gallon (19 L) pails and 55-gallon (208 L) drums, and has
a shelf life of one (1) year when stored in factory-sealed
containers at temperatures between 50° and 80°F (10 and
27°C).
DC315 Primer is a liquid-applied primer, manufactured by
International Fireproof Technology, Inc., and is supplied in
1- and 5-gallon (3.8 and 18.9 L) pails, and has a shelf life of
2 years when stored in factory-sealed containers at
temperatures between 50° and 80°F (10 and 27°C).
DTM Bonding Primer is a waterborne, acrylic emulsion,
bonding primer manufactured by Sherwin-Williams. The
primer is supplied in 1- and 5-gallon (3.8 and 18.9 L)
containers, and has a shelf life of three (3) years when
stored in factory-sealed containers at temperatures
between 50° and 100°F (10 and 38°C).
3.2 Vapor Retarder:
When a minimum thickness of 18 mils WFT [0.018 inch
(0.46 mm)] of DC315 is applied to a minimum thickness of
2 inches (50.8 mm) of open-cell spray-applied foam plastic
insulation, the assembly has a vapor permeance greater
than 1 and less than 10 perms (5.7x10 kg/Pa-s-m2) when
tested in accordance with ASTM E96 procedure A
(desiccant method), and qualifies as a Class III vapor
retarder.
3.3 Surface Burning Characteristics:
When tested in accordance with ASTM E84/UL 723, at a
thickness of 13 mils WFT [0.013 inch (0.33 mm)], DC315
has a flame spread index of 25 or less and a smoke-
developed index of 450 or less. The DC315 coated foam
assemblies listed in Table 1 were tested in accordance with
NFPA 286 and comply with the acceptance criteria of 2018
IBC Section 803.1.1.1 (2015, 2012 and 2009 IBC Section
803.1.2.1 and 2006 IBC Section 803.2.1) and 2018, 2015,
2012 and 2009 IRC R302.9.4 (2006 IRC Section R315.4)
and is permitted to be used where a Class A classification
in accordance with ASTM E 84 or UL 723 is required by
2018 IBC Section 803.13 (2015 IBC Section 803.11, 2012
and 2009 IBC Section 803.9 and 2006 IBC Section 803.5).
4.0 DESIGN AND INSTALLATION
4.1 Installation – General:
DC315 must be applied in accordance with the
manufacturer’s published application instructions and this
report. A copy of the instructions must be available on the
job site at all times.
DC315 must be mechanically mixed prior to application.
The coating is applied to the required thickness using spray
equipment, a brush or a roller having a medium nap.
Surfaces to be coated must be inspected in accordance with
the manufacturer’s published installation instructions and
must be dry, clean, and free of dirt, loose debris and other
substances that could interfere with the adhesion of the
ESR-3702 | Most Widely Accepted and Trusted Page 2 of 13
coating. The coating must not be applied when the ambient
or surface temperature is below 50°F (10°C) or above 90°F
(32° C) and relative humidity of more than 85%. The
manufacturer must be consulted for specific application
conditions.
4.2 Application without a Prescriptive Thermal Barrier:
The DC315 coating may be applied over spray-applied foam
plastic insulations listed in Table 1 without covering the
coated assembly with the thermal barrier prescribed in IBC
Section 2603.4 and IRC Section R316.4 (2006 IRC Section
R314.4).
The DTM Bonding Primer, when used as part of the
assemblies listed in Table 1, must be installed in
accordance with the manufacturer’s published installation
instructions.
4.3 Application without a Prescriptive Ignition Barrier:
4.3.1 General: Where spray-applied foam plastic
insulations listed in Table 2 are installed in attics and crawl
spaces without the ignition barrier prescribed in IBC Section
2603.4.1.6 and 2018, 2015, 2012 and 2009 IRC Sections
R316.5.3 and R316.5.4 (2006 IRC Sections R314.5.3 and
R314.5.4) the installation must be in accordance with
Sections 4.3.2 and 4.3.3, and the following conditions apply:
a. Entry to the attic or crawl space is only to service
utilities, and no storage is permitted.
b. There are no interconnected attic or crawl space areas.
c. Air in the attic or crawl space is not circulated to other
parts of the building.
d. Attic ventilation is provided when required by 2018 IBC
Section 1202.2 (2015, 2012, 2009 and 2006 IBC
Section 1203.2) or IRC Section R806, except when air-
impermeable insulation is permitted in unvented attics
in accordance with the 2018 IBC Section 1202.3 (2015
IBC Section 1203.3) or 2018, 2015 and 2012 IRC
Section R806.5 (2009 IRC Section R806.4).
e. Under-floor (crawl space) ventilation is provided when
required by 2018 IBC Section 1202.4 [2015 IBC Section
1203.4 (2012, 2009 and 2006 IBC Section 1203.3) or
IRC Section R408.1, as applicable.
f. Combustion air is provided in accordance with IMC
(International Mechanical Code®) Section 701.
4.3.2 In attics and crawl spaces: In attics, the insulation
may be spray-applied to the underside of roof sheathing or
roof rafters, and/or vertical surfaces; and in crawl spaces,
the insulation may be spray-applied to the underside of
floors and/or vertical surfaces provided the assembly
conforms to one of the assemblies described in Table 2.
4.3.3 Use on Attic Floors: The insulation may be installed
between and over the joists in attic floor at the maximum
thickness set forth in Table 2. The insulation must be
separated from the interior of the building by an approved
thermal barrier. An ignition barrier prescribed in IBC Section
2603.4.1.6 and 2018, 2015, 2012 and 2009 IRC Sections
R316.5.3 and R316.5.4 (2006 IRC Sections R314.5.3 and
R314.5.4) may be omitted.
4.4 Exterior Walls in Types I, II, III and IV Construction:
Carlisle Spray Foam Insulation SealTite™ Pro Closed-Cell
spray foam insulation (ESR-2072) may be installed in or on
exterior walls of buildings of Type I, II, III and IV construction
complying with IBC Section 2603.5 and as described in this
section. The maximum thickness of the foam plastic
installed on the exterior of the sheathing or installed in stud
cavities must be as described in Table 3. The potential heat
of Carlisle Spray Foam Insulation SealTite™ Pro Closed
Cell spray-applied insulation is 1838 Btu/ft2 (20.9 MJ/m 2) per
inch of thickness. The wall assembly must be as described
in Table 3.
5.0 CONDITIONS OF USE
The DC315 coating described in this report complies with,
or is a suitable alternative to what is specified in, those
codes listed in Section 1.0 of this report, subject to the
following conditions:
5.1 Application must comply with this report, the
manufacturer’s published installation instructions, and
the applicable code. A copy of the installation
instructions must be on the job site during application
of the coating. In the event of a conflict between the
manufacturer’s published installation instructions and
this report, this report and the code govern.
5.2 The application of additional interior finishes over the
DC315 coating is limited to interior /exterior satin latex
paint applied at an average wet film thickness of
8.0 mils (0.20 mm) or interior/exterior coating
consisting of 30% silicon alkyd having a VOC (less
exempt solvents) of no more than 340 g/L (2.8 lb/gal)
and a volume solids content of 62% applied at a
maximum average wet film thickness of 8 mils
(0.20 mm). The use of either of the two interior finishes
in conjunction with a vapor retardant coating is outside
the scope of this report.
5.3 Installation in accordance with this report is for the
specific assemblies and spray-applied foam plastic
insulations described in Tables 1 and 2. The spray-
applied foam plastic insulation must be installed in
accordance with the requirements set forth in the
specific ICC-ES evaluation report noted. For spray-
applied foam plastic insulation that is not covered in an
ICC-ES evaluation report, the evaluation is limited as
noted in Tables 1 and 2, Footnote 3.
5.4 When used in or on the exterior walls of buildings of
Type I, II III or IV construction, the wall assembly must
conform to those described in Section 4.7, Table 3 and
Figures 1 - 4.
5.5 The coating is manufactured in Taoyuan, Taiwan and
Irvine, California, under a quality control program with
inspections by ICC-ES.
6.0 EVIDENCE SUBMITTED
6.1 Data in accordance with the ICC-ES Acceptance
Criteria for Fire-Protective Coatings Applied to Spray-
applied Foam Plastic Insulation Installed without a
Code-prescribed Thermal Barrier (AC456), dated
October 2015 (Editorially revised January 2021),
including room corner fire testing in accordance with
NFPA 286.
6.2 Report of testing in accordance with ASTM E84 (UL
723).
6.3 Report of vapor permeance test in accordance with
ASTM E96 (Desiccant method).
6.4 Report of testing in accordance with Appendix X of
AC377.
6.5 Report of fire propagation characteristics testing in
accordance with NFPA 285 and associated fire
engineering analysis supporting the NFPA 285 test
report.
ESR-3702 | Most Widely Accepted and Trusted Page 3 of 13
6.6 Data on accelerated weathering, resistance to humidity
and thermal cycling testing in accordance with ASTM
D5894, ASTM D4585 and ASTM D3346, respectively.
7.0 IDENTIFICATION
7.1 All containers of DC315 coating must be labeled with
the manufacturer’s name (International Fireproof
Technology Inc.) and address; the product name; the
date of manufacture, the shelf life or expiration date;
the manufacturer’s instructions for application, and the
evaluation report number (ESR-3702).
The spray-applied foam plastic insulations must be
labeled in accordance with the applicable evaluation
report (see Table 1).
7.2 The report holder’s contact information is the following:
INTERNATIONAL FIREPROOF TECHNOLOGY INC.
17528 VON KARMAN AVENUE
IRVINE, CALIFORNIA 92614
(949) 975-8588
www.painttoprotect.com
ptp@painttoprotect.com
TABLE 1—USE OF INSULATION WITHOUT A PRESCRIPTIVE THERMAL BARRIER
(TESTED IN ACCORDANCE WITH NFPA 286)
INSULATION
COMPANY NAME
INSULATION
PRODUCT NAME
M AXIMUM
THICK NESS (in.)
(Vertical Surfaces)
MAXIMUM
THICKNESS (in.)
(Overhead
Surfaces)
DC315 COATING
MINIMUM AVERAGE
THICK NESS1
(Applied to all Foam
Surfaces)
MINIMUM
THEORETICAL
A PPLIC ATION
RATE OF
COATING 2
Acme Urethanes WC-50
(See Note 3) 8 14 12 mils DFT
18 mils WFT 1.13 gal/100 ft2
AMD Distribution LLC Diamond Back
(ESR-4438) 71/2 111/2 9 mils DFT
14 mils WFT 0.88 gal/100 ft2
Barnhardt Manufacturing
Company dba NCFI
Polyurethanes
InsulStar® Light 12-008
(See Note 3) 8 14 9 mils DFT
14 mils WFT 0.88 gal/100 ft2
Barnhardt Manufacturing
Company dba NCFI
Polyurethanes
InsulBloc®
(ESR-1615) 51/2 91/2 9 mils DFT
14 mils WFT 0.88 gal/100 ft2
Barnhardt Manufacturing
Company dba NCFI
Polyurethanes
InsulStar®
(ESR-1615) 51/2 91/2 9 mils DFT
14 mils WFT 0.88 gal/100 ft2
Barnhardt Manufacturing
Company dba NCFI
Polyurethanes
InsulStar® 1.7 SmartSPF
(See Note 3) 51/2 91/2 9 mils DFT
14 mils WFT 0.88 gal/100 ft2
Barnhardt Manufacturing
Company dba NCFI
Polyurethanes
Sealtite OCX
(See Note 3) 10 14 12 mils DFT
18 mils WFT 1.13 gal/100 ft2
Barnhardt Manufacturing
Company dba NCFI
Polyurethanes
InsulStar®SmartSPF
(See Note 3) 6 10 9 mils DFT
14 mils WFT 0.88 gal/100 ft2
BASF Corporation ENERTITE® G
(ESR-3102) 81/2 14 9 mils DFT
14 mils WFT 0.88 gal/100 ft2
BASF Corporation ENERTITE® NM
(ESR-3102) 81/2 14 9 mils DFT
14 mils WFT 0.88 gal/100 ft2
BASF Corporation SPRAYTITE 158
(ESR-2642) 51/2 91/2 9 mils DFT
14 mils WFT 0.88 gal/100 ft2
BASF Corporation SPRAYTITE 178
(ESR-2642) 51/2 111/2 14 mils DFT
20 mils WFT 1.25 gal/100 ft2
BASF Corporation SPRAYTITE 81205
(ESR-2642) 51/2 91/2 9 mils DFT
14 mils WFT 0.88 gal/100 ft2
BASF Corporation SPRAYTITE 81206
(ESR-2642) 51/2 111/2 14 mils DFT
20 mils WFT 1.25 gal/100 ft2
BASF Corporation SPRAYTITE SP
(ESR-2642) 51/2 91/2 9 mils DFT
14 mils WFT 0.88 gal/100 ft2
BASF Corporation WALLTITE 200
(ESR-2642) 51/2 111/2 14 mils DFT
20 mils WFT 1.25 gal/100 ft2
BASF Corporation WALLTITE HP+
(ESR-2642) 51/2 111/2 14 mils DFT
20 mils WFT 1.25 gal/100 ft2
BASF Corporation WALLTITE US
(ESR-2642) 51/2 111/2 14 mils DFT
20 mils WFT 1.25 gal/100 ft2
BASF Corporation WALLTITE US-N
(ESR-2642) 51/2 111/2 14 mils DFT
20 mils WFT 1.25 gal/100 ft2
BASF Corporation SPRAYTITE LWP-L
(See Note 3) 51/2 91/2 9 mils DFT
14 mils WFT 0.88 gal/100 ft2
BASF Corporation WALLTITE LWP
(See Note 3) 51/2 111/2 14 mils DFT
20 mils WFT 1.25 gal/100 ft2
BASF Corporation WALLTITE HP+S
(See Note 3) 51/2 111/2 14 mils DFT
20 mils WFT 1.25 gal/100 ft2
Carlisle Spray Foam
Insulation
Foamsulate 50
(See Note 3) 81/2 14 9 mils DFT
14 mils WFT 0.88 gal/100 ft2
ESR-3702 | Most Widely Accepted and Trusted Page 4 of 13
INSULATION
COMPANY NAME
INSULATION
PRODUCT NAME
MAXIMUM
THICKNESS (in.)
(Vertical Surfaces)
MAXIMUM
THICKNESS (in.)
(Overhead
Surfaces)
DC315 COATING
MINIMUM AVERAGE
THICK NESS1
(Applied to all Foam
Surfaces)
MINIMUM
THEORETICAL
A PPLIC ATION
RATE OF
COATING 2
Carlisle Spray Foam
Insulation
Foamsulate 50 HY
(See Note 3) 81/2 14 9 mils DFT
14 mils WFT 0.88 gal/100 ft2
Carlisle Spray Foam
Insulation
Foamsulate 70
(See Note 3) 81/2 14 9 mils DFT
14 mils WFT 0.88 gal/100 ft2
Carlisle Spray Foam
Insulation
Foamsulate Closed Cell
(See Note 3) 51/2 91/2 9 mils DFT
14 mils WFT 0.88 gal/100 ft2
Carlisle Spray Foam
Insulation
Foamsulate HFO
(See Note 3) 51/2 91/2 9 mils DFT
14 mils WFT 0.88 gal/100 ft2
Carlisle Spray Foam
Insulation
Foamsulate OCX
(See Note 3) 9 14 9 mils DFT
14 mils WFT 0.88 gal/100 ft2
Carlisle Spray Foam
Insulation
SealTite PRO Closed
Cell
(See Note 3)
51/2 91/2 9 mils DFT
14 mils WFT 0.88 gal/100 ft2
Carlisle Spray Foam
Insulation
SealTite PRO High Yield
(See Note 3) 81/2 14 9 mils DFT
14 mils WFT 0.88 gal/100 ft2
Carlisle Spray Foam
Insulation
SealTite PRO No Mix
(See Note 3) 81/2 14 9 mils DFT
14 mils WFT 0.88 gal/100 ft2
Carlisle Spray Foam
Insulation
SealTite PRO No Trim 21
(See Note 3) 81/2 14 9 mils DFT
14 mils WFT 0.88 gal/100 ft2
Carlisle Spray Foam
Insulation
SealTite PRO OCX
(See Note 3) 9 14 9 mils DFT
14 mils WFT 0.88 gal/100 ft2
Carlisle Spray Foam
Insulation
SealTite PRO One Zero
Closed Cell
(See Note 3)
51/2 91/2 9 mils DFT
14 mils WFT 0.88 gal/100 ft2
Carlisle Spray Foam
Insulation
SealTite PRO Open Cell
(See Note 3) 81/2 14 9 mils DFT
14 mils WFT 0.88 gal/100 ft2
CertainTeed Certaspray X OC
(See Note 3) 51/4 14 13 mils DFT
20 mils WFT 1.25 gal/100 ft2
Commercial Thermal
Solutions, Inc.
Tiger Foam® E-84 Fire-
Rated SPF Class 1 Spray
Foam System
(ESR-3183)
31/2 31/2 13 mils DFT
20 mils WFT 1.25 gal/100 ft2
Creative Polymer Solutions Accufoam 170
(See Note 3) 51/2 91/2 13 mils DFT
19 mils WFT 1.19 gal/100 ft2
Creative Polymer Solutions Accufoam 45
(See Note 3) 8 14 12 mils DFT
18 mils WFT 1.13 gal/100 ft2
DAP Foam, Inc.
Touch N' Foam
Professional Class I FR
Spray Foam System
(ESR-3052)
31/2 31/2 13 mils DFT
20 mils WFT 1.25 gal/100 ft2
DAP Foam, Inc.
Touch N' Seal Class I FR
Spray Foam System
(ESR-3052)
31/2 31/2 13 mils DFT
20 mils WFT 1.25 gal/100 ft2
DAP Foam, Inc.
TNF/TNS Class I FR
HFO Spray Foam
System
(See Note 3)
31/4 31/4 12 mils DFT
18 mils WFT 1.13 gal/100 ft2
Demilec (USA) Inc. Agribalance®
(ESR-2600) 71/2 111/2 12 mils DFT
18 mils WFT 1.13 gal/100 ft2
Demilec (USA) Inc. Demilec APX® 2.0
(ESR-3703) 51/4 14 13 mils DFT
20 mils WFT 1.25 gal/100 ft2
Demilec (USA) Inc. Demilec APX™
(ESR-3470) 8 10 13 mils DFT
20 mils WFT 1.25 gal/100 ft2
Demilec (USA) Inc. Demilec Heatlok® HFO
(ESR-4073) 71/2 111/2 9 mils DFT
14 mils WFT 0.88 gal/100 ft2
Demilec (USA) Inc. Demilec Heatlok® XT-s
(ESR-3824) 71/2 111/2 9 mils DFT
14 mils WFT 0.88 gal/100 ft2
Demilec (USA) Inc. Demilec Heatlok® XT-w
(ESR-3883) 71/2 111/2 12 mils DFT
18 mils WFT 1.13 gal/100 ft2
Demilec (USA) Inc.
Demilec SEALECTION®
500
(ESR-1172)
71/2 111/2 12 mils DFT
18 mils WFT 1.13 gal/100 ft2
Demilec (USA) Inc. HEATLOK SOY® 200 PLUS
(ESR-3210) 71/2 111/2 12 mils DFT
18 mils WFT 1.13 gal/100 ft2
Demilec (USA) Inc. Heatlok® Eco
(ESR-3198) 51/2 91/2 14 mils DFT
22 mils WFT 1.38 gal/100 ft2
Demilec (USA) Inc. Sealection NM
(ESR-2668) 71/2 111/2 12 mils DFT
18 mils WFT 1.13 gal/100 ft2
ESR-3702 | Most Widely Accepted and Trusted Page 5 of 13
INSULATION
COMPANY NAME
INSULATION
PRODUCT NAME
MAXIMUM
THICKNESS (in.)
(Vertical Surfaces)
MAXIMUM
THICKNESS (in.)
(Overhead
Surfaces)
DC315 COATING
MINIMUM AVERAGE
THICK NESS1
(Applied to all Foam
Surfaces)
MINIMUM
THEORETICAL
A PPLIC ATION
RATE OF
COATING 2
Elastochem Specialty
Chemicals, Inc.
Elastochem®
Insulthane® Extreme
(ESR-3809)
71/4 71/4 12 mils DFT
18 mils WFT 1.13 gal/100 ft2
Elastochem Specialty
Chemicals, Inc.
Insulthane
(See Note 3) 51/2 91/2 9 mils DFT
14 mils WFT 0.88 gal/100 ft2
EnergyOne America EOA 2000
(See Note 3) 51/2 91/2 9 mils DFT
14 mils WFT 0.88 gal/100 ft2
EnergyOne America EOA 500
(ESR-3686) 81/2 14 9 mils DFT
14 mils WFT 0.88 gal/100 ft2
Franklin International, Inc.
Titebond Weathermaster
Superfoam
(See ESR-4099)
2 2 13 mils DFT
20 mils WFT 1.25 gal/100 ft2
Gaco Western F1850
(See Note 3) 51/2 91/2 9 mils DFT
14 mils WFT 0.88 gal/100 ft2
Gaco Western Gaco 183M
(See Note 3) 51/2 91/2 9 mils DFT
14 mils WFT 0.88 gal/100 ft2
Gaco Western GACO F1880
(See Note 3) 9 12 9 mils DFT
14 mils WFT 0.88 gal/100 ft2
Gaco Western Gaco Firestop2 F5001
(See Note 3) 18 18 12 mils DFT
18 mils WFT 1.13 gal/100 ft2
Gaco Western Gaco Green 052N
(See Note 3) 111/4 111/4 9 mils DFT
14 mils WFT 0.88 gal/100 ft2
Gaco Western GacoEZSpray F4500
(See Note 3) 81/2 14 9 mils DFT
14 mils WFT 0.88 gal/100 ft2
General Coatings
Manufacturing Corp.
Ultrathane 050
(See Note 3) 8 10 13 mils DFT
20 mils WFT 1.25 gal/100 ft2
General Coatings
Manufacturing Corp.
Ultra-Thane 230
(ESR-3033) 51/2 71/2
DTM Bonding Primer
3 mils DFT/ 4 mils
WFT
&
DC315
12 mils DFT/ 18 mils
WFT
0.25 gal/100 ft2
&
1.13 gal/100 ft2
General Coatings
Manufacturing Corp.
Ultrathane 202
(See Note 3) 8 12 12 mils DFT
18 mils WFT 1.13 gal/100 ft2
General Coatings
Manufacturing Corp.
Ultrathane 170
(See Note 3) 8 12 11 mils DFT
18 mils WFT 1.00 gal/100 ft2
General Coatings
Manufacturing Corp.
Ultrathane 205 HFO
(See Note 3) 8 12 11 mils DFT
18 mils WFT 1.00 gal/100 ft2
Guardian Energy
Technologies
Foam It Green
(See Note 3) 31/2 31/2 13 mils DFT
20mils WFT 1.25 gal/100 ft2
Henry Company Permax 1.8
(See Note 3) 111/4 111/4 14 mils DFT
21 mils WFT 1.31 gal/100 ft2
Henry Company Permax 2.0X
(ESR-3647) 51/2 91/2 9 mils DFT
14 mils WFT 0.88 gal/100 ft2
Henry Company Permax 2.0X Fast
(ESR-3647) 51/2 91/2 9 mils DFT
14 mils WFT 0.88 gal/100 ft2
Huntsman International,
LLC
CertaSpray CC
(ESR-3758) 51/2 91/2 9 mils DFT
14 mils WFT 0.88 gal/100 ft2
ICP Adhesives & Sealants,
Inc.
Handi-Foam E-84 Class
1(A) Spray Foam System
(ESR-2717)
31/2 31/2 13 mils DFT
20mils WFT 1.25 gal/100 ft2
Icynene, Inc. LD C 50 No Mix
(See Note 3) 81/2 14 9 mils DFT
14 mils WFT 0.88 gal/100 ft2
Icynene, Inc. Classic
(ESR-1826) 81/2 14 9 mils DFT
14 mils WFT 0.88 gal/100 ft2
Icynene, Inc. Classic Plus
(ESR-1826) 81/2 14 9 mils DFT
14 mils WFT 0.88 gal/100 ft2
Icynene, Inc. Classic Ultra
(ESR-1826) 81/2 14 9 mils DFT
14 mils WFT 0.88 gal/100 ft2
Icynene, Inc. Classic Ultra Select
(ESR-1826) 81/2 14 9 mils DFT
14 mils WFT 0.88 gal/100 ft2
Icynene, Inc. Icynene MD-C-200
(ESR-3199) 6 10 14 mils DFT
22 mils WFT 1.38 gal/100 ft2
Icynene, Inc. Icynene ProSeal
(ESR-3500) 51/2 91/2 9 mils DFT
14 mils WFT 0.88 gal/100 ft2
Icynene, Inc. Icynene ProSeal LE
(ESR-3500) 51/2 91/2 9 mils DFT
14 mils WFT 0.88 gal/100 ft2
Icynene, Inc. ProSeal HFO
(See Note 3) 51/2 91/2 9 mils DFT
14 mils WFT 0.88 gal/100 ft2
ESR-3702 | Most Widely Accepted and Trusted Page 6 of 13
INSULATION
COMPANY NAME
INSULATION
PRODUCT NAME
MAXIMUM
THICKNESS (in.)
(Vertical Surfaces)
MAXIMUM
THICKNESS (in.)
(Overhead
Surfaces)
DC315 COATING
MINIMUM AVERAGE
THICK NESS1
(Applied to all Foam
Surfaces)
MINIMUM
THEORETICAL
A PPLIC ATION
RATE OF
COATING 2
Icynene, Inc. ProSeal Max HFC
(See Note 3) 6 91/2 9 mils DFT
14 mils WFT 0.88 gal/100 ft2
Icynene-LaPolla, Inc. Foam-Lok FL 450
(ESR-4242) 81/2 14 9 mils DFT
14 mils WFT 0.88 gal/100 ft2
Icynene-LaPolla, Inc. Prime Gold
(ESR-4323) 81/2 14 9 mils DFT
14 mils WFT 0.88 gal/100 ft2
Johns Manville JM Corbond III
(See Note 3) 51/2 91/2 9 mils DFT
14 mils WFT 0.88 gal/100 ft2
Johns Manville JM Corbond MCS™
(ESR-3159) 71/4 91/4 14 mils DFT
22 mils WFT 1.38 gal/100 ft2
Johns Manville JM Corbond oc
(See Note 3) 71/2 111/2 12 mils DFT
18 mils WFT 1.13 gal/100 ft2
Johns Manville JM Corbond ocx SPF
(See Note 3) 9 14 9 mils DFT
14 mils WFT 0.88 gal/100 ft2
Johns Manville JM MCS+
(See Note 3) 51/2 91/2 9 mils DFT
14 mils WFT 0.88 gal/100 ft2
Johns Manville JM Gen IV 51/2 91/2 9 mils DFT
14 mils WFT 0.88 gal/100 ft2
LaPolla Industries, Inc. Foam -Lok FL2000
(ESR-2629) 51/2 91/2 9 mils DFT
14 mils WFT 0.88 gal/100 ft2
LaPolla Industries, Inc. Foam -Lok FL500
(ESR-2847) 81/2 14 9 mils DFT
14 mils WFT 0.88 gal/100 ft2
LaPolla Industries, Inc. Lapolla FL 2000 4G
(See Note 3) 51/2 91/2 9 mils DFT
14 mils WFT 0.88 gal/100 ft2
LaPolla Industries, Inc. Lapolla Foam -Lok FL 750
(ESR-4322) 81/2 14 9 mils DFT
14 mils WFT 0.88 gal/100 ft2
LaPolla Industries, Inc. Foam -Lok FL2000-3G
(ESR-2847) 8 14 16 mils DFT
24 mils WFT 1.50 gal/100 ft2
Natural Polymers, LLC Natural-Therm ™ 0.5 IB
(See Note 3) 91/2 141/2 9 mils DFT
14 mils WFT 0.88 gal/100 ft2
Natural Polymers, LLC Natural-Therm ™ 0.50 PCF
(See Note 3) 91/2 141/2 9 mils DFT
14 mils WFT 0.88 gal/100 ft2
Natural Polymers, LLC Natural-Therm ™ 2.0 IBS
(See Note 3) 51/2 91/2 9 mils DFT
14 mils WFT 0.88 gal/100 ft2
Natural Polymers, LLC Natural-Therm ™ 2.0 IBW
(See Note 3) 51/2 91/2 9 mils DFT
14 mils WFT 0.88 gal/100 ft2
Natural Polymers, LLC Natural-Therm ™ Light
(See Note 3) 91/2 141/2 9 mils DFT
14 mils WFT 0.88 gal/100 ft2
Natural Polymers, LLC Natural-Therm ™ ZERO
(See Note 3) 51/2 91/2 9 mils DFT
14 mils WFT 0.88 gal/100 ft2
North American Spray
Foam Polymers
EcoPolySeal
(ESR-4483) 71/2 111/2 12 mils DFT
18 mils WFT 1.13 gal/100 ft2
North American Spray
Foam Polymers
EPS 2000
(ESR-4484) 71/2 111/2 12 mils DFT
18 mils WFT 1.13 gal/100 ft2
Nu-Wool Company
Incorporated
Nu-Seal 0.5
(See Note 3) 91/2 141/2 9 mils DFT
14 mils WFT 0.88 gal/100 ft2
Nu-Wool Company
Incorporated
Nu-Seal 2.0 W
(See Note 3) 51/2 14 9 mils DFT
14 mils WFT 0.88 gal/100 ft2
Polygreen Solutions GreenSeal 44
(See Note 3) 8 14 12 mils DFT
18 mils WFT 1.13 gal/100 ft2
Preferred Solutions, Inc. Staycell® 302
(See Note 3) 51/2 91/2 9 mils DFT
14 mils WFT 0.88 gal/100 ft2
Profoam ProSeal
(ESR-3835) 51/2 91/2 9 mils DFT
14 mils WFT 0.88 gal/100 ft2
Profoam ProSeal Plus
(See Note 3) 51/2 91/2 9 mils DFT
14 mils WFT 0.88 gal/100 ft2
Profoam ProFill Plus
(See Note 3) 81/2 14 9 mils DFT
14 mils WFT 0.88 gal/100 ft2
Purinova Sp. z.o.o. Purinova PURIOS 500
(ESR-4165) 8 14 12 mils DFT
18 mils WFT 1.13 gal/100 ft2
Purinova Sp. z.o.o. Crossing 450
(ESR-4003) 8 14 12 mils DFT
18 mils WFT 1.13 gal/100 ft2
RHH Foam Systems Versi-Foam Class I
(See Note 3) 31/2 31/2 13 mils DFT
20 mils WFT 1.25 gal/100 ft2
Rhino Linings Corporation ThermalGuard CC2
(ESR-2100) 51/2 91/2 9 mils DFT
14 mils WFT 0.88 gal/100 ft2
Rhino Linings Corporation ThermalGuard OC.5
(ESR-2100) 71/2 111/2 13 mils DFT
18 mils WFT 1.13 gal/100 ft2
SES Foam Nexseal 2.0
(See Note 3) 51/2 91/2 9 mils DFT
14 mils WFT 0.88 gal/100 ft2
ESR-3702 | Most Widely Accepted and Trusted Page 7 of 13
INSULATION
COMPANY NAME
INSULATION
PRODUCT NAME
MAXIMUM
THICKNESS (in.)
(Vertical Surfaces)
MAXIMUM
THICKNESS (in.)
(Overhead
Surfaces)
DC315 COATING
MINIMUM AVERAGE
THICK NESS1
(Applied to all Foam
Surfaces)
MINIMUM
THEORETICAL
A PPLIC ATION
RATE OF
COATING 2
SES Foam Nexseal 2.0 LE
(See Note 3) 51/2 91/2 9 mils DFT
14 mils WFT 0.88 gal/100 ft2
SES Foam SES 2.0
(See Note 3) 51/2 91/2 9 mils DFT
14 mils WFT 0.88 gal/100 ft2
SES Foam SES 2.0 LE
(See Note 3) 51/2 91/2 9 mils DFT
14 mils WFT 0.88 gal/100 ft2
SES Foam SES Foam Easyseal 0.5 lb
(ESR-3375) 81/2 14 9 mils DFT
14 mils WFT 0.88 gal/100 ft2
SES Foam Sucraseal™ 0.5
(ESR-3375) 9 14 9 mils DFT
14 mils WFT 0.88 gal/100 ft2
Soprema SupraSeal
(See Note 3) 71/4 71/4 12 mils DFT
18 mils WFT 1.13 gal/100 ft2
Specialty Products, Inc.
(S.P.I)
Envelo-Seal ™ 0.5 OC
(See Note 3) 91/2 141/2 9 mils DFT
14 mils WFT 0.88 gal/100 ft2
Specialty Products, Inc.
(S.P.I)
Envelo-Seal ™ 2.0 IBW
(See Note 3) 51/2 14 9 mils DFT
14 mils WFT 0.88 gal/100 ft2
Sustainable Polymer
Products
0.5 OC
(See Note 3) 81/2 14 9 mils DFT
14 mils WFT 0.88 gal/100 ft2
Sustainable Polymer
Products
0.5 OCX
(See Note 3) 9 14 9 mils DFT
14 mils WFT 0.88 gal/100 ft2
Sustainable Polymer
Products
2.0 CC
(See Note 3) 51/2 91/2 9 mils DFT
14 mils WFT 0.88 gal/100 ft2
SWD Urethane Quik-Shield 100X
(See Note 3) 7 11 12 mils DFT
18 mils WFT 1.13 gal/100 ft2
SWD Urethane Quik-Shield 104
(See Note 3) 8 14 12 mils DFT
18 mils WFT 1.13 gal/100 ft2
SWD Urethane Quik-Shield 106
(See Note 3) 111/4 111/4 15 mils DFT
24 mils WFT 1.50 gal/100 ft2
SWD Urethane Quik-Shield 108
(See Note 3) 81/2 14 9 mils DFT
14 mils WFT 0.88 gal/100 ft2
SWD Urethane Quik-Shield 112
(See Note 3) 51/2 91/2 9 mils DFT
14 mils WFT 0.88 gal/100 ft2
DuPont de Nemours, Inc. FROTH-PAK™
(ESR-3228) 31/2 31/2 14 mils DFT
20 mils WFT 1.25 gal/100 ft2
DuPont de Nemours, Inc.
STYROFOAM™ Spray
Polyurethane Foam
CM2045
(ESR-2670)
91/2 91/2 15 mils DFT
22 mils WFT 1.38 gal/100 ft2
The Spray Market SPM-200
(ESR-4195) 71/2 111/2 9 mils DFT
14 mils WFT 0.88 gal/100 ft2
Thermoseal Thermoseal OCX
(See Note 3) 71/2 111/2 12 mils DFT
18 mils WFT 1.13 gal/100 ft2
Thermoseal 2000
(See Note 3) 51/2 91/2 9 mils DFT
14 mils WFT 0.88 gal/100 ft2
Thermoseal Thermoseal CCX
(ESR-4137) 71/2 111/2 9 mils DFT
14 mils WFT 0.88 gal/100 ft2
Thermoseal TS 5G
(See Note 3) 51/2 91/2 9 mils DFT
14 mils WFT 0.88 gal/100 ft2
Thermoseal TS One
(See Note 3) 51/2 91/2 13 mils DFT
20 mils WFT 1.25 gal/100 ft2
Thermoseal TS360
(See Note 3) 81/2 14 13 mils DFT
20 mils WFT 1.25 gal/100 ft2
Thermoseal TS500
(See Note 3) 8 14 12 mils DFT
18 mils WFT 1.13 gal/100 ft2
Thermoseal TS800
(See Note 3) 8 14 12 mils DFT
18 mils WFT 1.13 gal/100 ft2
Universal Polymers
Corporation
UPC 500
(ESR-3803) 81/2 14 12 mils DFT
18 mils WFT 1.13 gal/100 ft2
Universal Polymers
Corporation
UPC 2.0 High Lift
(See Note 3) 8 12 12 mils DFT
18 mils WFT 1.13 gal/100 ft2
Universal Polymers
Corporation
UPC 1.7
(See Note 3) 8 12 11 mils DFT
18 mils WFT 1.00 gal/100 ft2
Universal Polymers
Corporation
UPC 2.0
(See Note 3) 8 12 11 mils DFT
18 mils WFT 1.00 gal/100 ft2
Universal Polymers
Corporation
UPC 500 Max
(See Note 3) 8 14 14 mils DFT
21 mils WFT 1.31 gal/100 ft2
Urethane Technology
Company, Inc.
UTC 7040-0.5
(ESR-3244) 51/2 143/4 14 mils DFT
20 mils WFT 1.25 gal/100 ft2
Urethane Technology
Company, Inc.
UTC 7041-0.5
(ESR-3244) 51/2 143/4 14 mils DFT
20 mils WFT 1.25 gal/100 ft2
ESR-3702 | Most Widely Accepted and Trusted Page 8 of 13
INSULATION
COMPANY NAME
INSULATION
PRODUCT NAME
MAXIMUM
THICKNESS (in.)
(Vertical Surfaces)
MAXIMUM
THICKNESS (in.)
(Overhead
Surfaces)
DC315 COATING
MINIMUM AVERAGE
THICK NESS1
(Applied to all Foam
Surfaces)
MINIMUM
THEORETICAL
A PPLIC ATION
RATE OF
COATING 2
Victory Polymers Corp. VPC-HFO
(ESR-4491) 71/4 71/4 12 mils DFT
18 mils WFT 1.13 gal/100 ft2
Victory Polymers Corp. VPC-50 OCHY
(ESR-4502) 81/2 111/2 9 mils DFT
14 mils WFT 0.88 gal/100 ft2
Victory Polymers Inc.
VPC-CC SuperLift and
VPC-CC SuperYield
(ESR-4334)
71/2 111/2 12 mils DFT
18 mils WFT 1.13 gal/100 ft2
Victory Polymers Inc. VPC-OneStroke
(See Note 3) 71/2 111/2 12 mils DFT
18 mils WFT 1.13 gal/100 ft2
Victory Polymers Inc. VPC-HiR-OC
(See Note 3) 81/2 111/2 9 mils DFT
14 mils WFT 0.88 gal/100 ft2
Victory Polymers Inc. VPC-50NF
(ESR-4657) 71/2 111/2 12 mils DFT
18 mils WFT 1.13 gal/100 ft2
Volatile Free, Inc. VFI-714
(See Note 3) 51/2 91/2 9 mils DFT
14 mils WFT 0.88 gal/100 ft2
Volatile Free, Inc. VFI-716
(See Note 3) 81/2 14 9 mils DFT
14 mils WFT 0.88 gal/100 ft2
XtremeSeal, LLC XtremeSeal 0.4 LX
(See Note 3) 81/2 14 9 mils DFT
14 mils WFT 0.88 gal/100 ft2
XtremeSeal, LLC XtremeSeal 0.5 LX
(See Note 3) 81/2 14 9 mils DFT
14 mils WFT 0.88 gal/100 ft2
XtremeSeal, LLC XtremeSeal 2.0 LE
(See Note 3) 51/2 91/2 9 mils DFT
14 mils WFT 0.88 gal/100 ft2
For SI: 1 inch = 25.4 mm; 1 mil = 0.0254 mm; 1 gallon = 3.38 L; 1 ft2 = 0.93 m2.
Notes:
1DFT = Dry Film Thickness; WFT = Wet Film Thickness
2As reported in the manufacturer’s application instructions. Actual application rate, based upon specific project conditions, must be in accordance with the
manufacturer’s application instructions.
3Recognition is limited to the NFPA 286 test data for the coated assembly described. Evaluation for compliance of the spray foam insulation with other applicable
requirements of AC377 and the IBC and IRC are outside the scope of the report.
TABLE 2—USE OF INSULATION WITHOUT A PRESCRIPTIVE IGNITION BARRIER
(TESTED IN ACCORDANCE WITH APPENDIX X OF AC377)
INSULATION
COMPANY NAME
INSULATION
PRODUCT NAME
MAXIMUM
THICKNESS (in.)
(Vertical Surfaces
and Attic Floors)
MAXIMUM
THICKNESS (in.)
(Underside of Roof
Sheathing and/or
Rafters, Underside
of Floors)
DC315 COATING
MINIMUM
AVERAGE
THICKNESS1
(Applied to all
Foam Surfaces)
MINIMUM
THEORETICAL
A PPLIC ATION
RATE OF
COATING 2
Acme Urethanes WC-50
(See Note 3) 8 14 3 mils DFT
4 mils WFT 0.25 gal/100 ft2
Barnhardt Manufacturing
Company dba NCFI
Polyurethanes
InsulStar® Light (12-008)
(See Note 3) 8 14 4 mils DFT
7 mils WFT 0.44 gal/100 ft2
BASF Corporation ENERTITE® G
(ESR-3102) 111/2 151/2 3 mils DFT
4 mils WFT 0.25 gal/100 ft2
BASF Corporation ENERTITE® NM
(ESR-3102) 111/2 151/2 3 mils DFT
4 mils WFT 0.25 gal/100 ft2
BASF Corporation SPRAYTITE 158
(ESR-2642) 51/2 111/2 3 mils DFT
4 mils WFT 0.25 gal/100 ft2
BASF Corporation SPRAYTITE 178
(ESR-2642) 51/2 111/2 3 mils DFT
4 mils WFT 0.25 gal/100 ft2
BASF Corporation SPRAYTITE 81205
(ESR-2642) 51/2 111/2 3 mils DFT
4 mils WFT 0.25 gal/100 ft2
BASF Corporation SPRAYTITE 81206
(ESR-2642) 51/2 111/2 3 mils DFT
4 mils WFT 0.25 gal/100 ft2
BASF Corporation SPRAYTITE SP
(ESR-2642) 51/2 111/2 3 mils DFT
4 mils WFT 0.25 gal/100 ft2
BASF Corporation WALLTITE HP+
(ESR-2642) 51/2 111/2 3 mils DFT
4 mils WFT 0.25 gal/100 ft2
BASF Corporation WALLTITE US
(ESR-2642) 51/2 111/2 3 mils DFT
4 mils WFT 0.25 gal/100 ft2
BASF Corporation WALLTITE US-N
(ESR-2642) 51/2 111/2 3 mils DFT
4 mils WFT 0.25 gal/100 ft2
Carlisle Spray Foam
Insulation
Foamsulate 50
(See Note 3) 12 12 3 mils DFT
4 mils WFT 0.25 gal/100 ft2
ESR-3702 | Most Widely Accepted and Trusted Page 9 of 13
INSULATION
COMPANY NAME
INSULATION
PRODUCT NAME
MAXIMUM
THICKNESS (in.)
(Vertical Surfaces
and Attic Floors)
MAXIMUM
THICKNESS (in.)
(Underside of Roof
Sheathing and/or
Rafters, Underside
of Floors)
DC315 COATING
MINIMUM
AVERAGE
THICKNESS1
(Applied to all
Foam Surfaces)
MINIMUM
THEORETICAL
A PPLIC ATION
RATE OF
COATING 2
Carlisle Spray Foam
Insulation
Foamsulate 70
(See Note 3) 14 14 3 mils DFT
4 mils WFT 0.25 gal/100 ft2
Carlisle Spray Foam
Insulation
SealTite PRO No Mix
(See Note 3) 12 12 3 mils DFT
4 mils WFT 0.25 gal/100 ft2
Carlisle Spray Foam
Insulation
SealTite PRO No Trim 21
(See Note 3) 14 14 3 mils DFT
4 mils WFT 0.25 gal/100 ft2
Creative Polymer Solutions Air Lok 170
(See Note 3) 51/2 91/2 3 mils DFT
4 mils WFT 0.25 gal/100 ft2
Creative Polymer Solutions Airl Lok 45
(See Note 3) 8 14 3 mils DFT
4 mils WFT 0.25 gal/100 ft2
DAP Foam, Inc.
TNF Class I FR HFO
Spray Foam System
(See Note 3)
31/4 31/4 4 mils DFT
6 mils WFT 0.38 gal/100 ft2
Demilec (USA) Inc. Agribalance®
(ESR-2600) 71/2 111/2 3 mils DFT
4 mils WFT 0.25 gal/100 ft2
Demilec (USA) Inc.
Demilec SEALECTION®
500
(ESR-1172)
71/2 111/2 3 mils DFT
4 mils WFT 0.25 gal/100 ft2
Demilec (USA) Inc. Heatlok® Eco
(ESR-3198) 111/2 111/2 3 mils DFT
4 mils WFT 0.25 gal/100 ft2
Gaco Western Gaco Green 052N
(See Note 3) 111/4 111/4 3 mils DFT
4 mils WFT 0.25 gal/100 ft2
Gaco Western GacoEZSpray F4500
(See Note 3) 12 16 3 mils DFT
4 mils WFT 0.25 gal/100 ft2
General Coatings
Manufacturing Corp.
Ultrathane 050
(See Note 3) 6 8 3 mils DFT
4 mils WFT 0.25 gal/100 ft2
General Coatings
Manufacturing Corp.
Ultra-Thane 230
(ESR-3033) 71/2 111/2 3 mils DFT
4 mils WFT 0.25 gal/100 ft2
General Coatings
Manufacturing Corp.
Ultra-Thane 202
(See Note 3) 71/2 111/2 3 mils DFT
4 mils WFT 0.25 gal/100 ft2
General Coatings
Manufacturing Corp.
Ultra-Thane 205
HFO/UPC 2.0 HFO
(See Note 3)
8 12 4 mils DFT
6 mils WFT 0.38 gal/100 ft2
General Coatings
Manufacturing Corp.
Ultra-Thane 205 HFO
High Lift / UPC 2.0 HFO
High Lift
(See Note 3)
8 12 4 mils DFT
6 mils WFT 0.38 gal/100 ft2
Huntsman Building
Solutions
SEALECTION® NM
(ESR-2668) 10 12 4 mils DFT
6 mils WFT 0.38 gal/100 ft2
Icynene, Inc. Classic
(ESR-1826) 51/2 14 3 mils DFT
4 mils WFT 0.25 gal/100 ft2
Icynene, Inc. Classic Plus
(ESR-1826) 8 14 3 mils DFT
4 mils WFT 0.25 gal/100 ft2
Icynene, Inc. Classic Ultra
(ESR-1826) 51/2 14 3 mils DFT
4 mils WFT 0.25 gal/100 ft2
Icynene, Inc. Classic Ultra Select
(ESR-1826) 51/2 14 3 mils DFT
4 mils WFT 0.25 gal/100 ft2
Icynene, Inc. Icynene MD-C-200
(ESR-3199) 8 14 3 mils DFT
4 mils WFT 0.25 gal/100 ft2
Icynene, Inc. Icynene ProSeal
(ESR-3500) 8 14 3 mils DFT
4 mils WFT 0.25 gal/100 ft2
Icynene, Inc. Icynene ProSeal LE
(ESR-3500) 8 14 3 mils DFT
4 mils WFT 0.25 gal/100 ft2
Icynene-LaPolla, Inc. Foam-Lok FL 450
(ESR-4242) 51/2 14 3 mils DFT
4 mils WFT 0.25 gal/100 ft2
Icynene-LaPolla, Inc. Prime Gold
(ESR-4323) 51/2 14 3 mils DFT
4 mils WFT 0.25 gal/100 ft2
Johns Manville JM Corbond III
(See Note 3) 71/2 91/2 3 mils DFT
4 mils WFT 0.25 gal/100 ft2
Johns Manville JM MCS+
(See Note 3) 71/2 91/2 3 mils DFT
4 mils WFT 0.25 gal/100 ft2
LaPolla Industries, Inc. Foam-Lok FL500
(ESR-2847) 51/2 111/2 3 mils DFT
4 mils WFT 0.25 gal/100 ft2
Natural Polymers, LLC Natural-Therm™ HFO
(See Note 3) 71/2 111/2 3 mils DFT
4 mils WFT 0.25 gal/100 ft2
Natural Polymers, LLC Natural -Therm™ ZERO
(See Note 3) 71/2 111/2 3 mils DFT
4 mils WFT 0.25 gal/100 ft2
Polygreen Solutions GreenSeal 44
(See Note 3) 8 14 3 mils DFT
4 mils WFT 0.25 gal/100 ft2
ESR-3702 | Most Widely Accepted and Trusted Page 10 of 13
INSULATION
COMPANY NAME
INSULATION
PRODUCT NAME
MAXIMUM
THICKNESS (in.)
(Vertical Surfaces
and Attic Floors)
MAXIMUM
THICKNESS (in.)
(Underside of Roof
Sheathing and/or
Rafters, Underside
of Floors)
DC315 COATING
MINIMUM
AVERAGE
THICKNESS1
(Applied to all
Foam Surfaces)
MINIMUM
THEORETICAL
A PPLIC ATION
RATE OF
COATING 2
PCC Prodex S.P z.o.o. Crossing 450
(ESR-4003) 8 14 3 mils DFT
4 mils WFT 0.25 gal/100 ft2
Profoam ProFill Plus
(See Note 3) 8 14 3 mils DFT
4 mils WFT 0.25 gal/100 ft2
Purinova Sp. z.o.o. Purinova PURIOS 500
(ESR-4165) 8 14 3 mils DFT
4 mils WFT 0.25 gal/100 ft2
Rhino Linings Corporation ThermalGuard OC .5
(ESR-2100) 8 12 3 mils DFT
4 mils WFT 0.25 gal/100 ft2
Rhino Linings Corporation ThermalGuard 1.0
(See Note 3) 8 12 3 mils DFT
4 mils WFT 0.25 gal/100 ft2
SES Foam SES Foam 0.5 lb
(ESR-3375) 91/2 111/2 3 mils DFT
4 mils WFT 0.25 gal/100 ft2
Sustainable Polymer
Products
0.5 OC HY
(See Note 3) 91/2 111/2 3 mils DFT
4 mils WFT 0.25 gal/100 ft2
SWD Urethane Quik-Shield 108
(See Note 3) 8 12 3 mils DFT
4 mils WFT 0.25 gal/100 ft2
ThermoSeal, LLC TS 360
(See Note 3) 81/2 14 4 mils DFT
6 mils WFT 0.25 gal/100 ft2
ThermoSeal, LLC TS 600
(See Note 3) 91/2 14 4 mils DFT
6 mils WFT 0.25 gal/100 ft2
ThermoSeal, LLC TS 800
(See Note 3) 91/2 14 4 mils DFT
6 mils WFT 0.38 gal/100 ft2
Universal Polymers
Corporation
UPC 500
(ESR-3803) 81/2 14 4 mils DFT
6 mils WFT 0.38 gal/100 ft2
Urethane Technology
Company, Inc.
UTC 7040-0.5
(ESR-3244) 51/2 143/4 3 mils DFT
4 mils WFT 0.25 gal/100 ft2
Urethane Technology
Company, Inc.
UTC 7041-0.5
(ESR-3244) 51/2 143/4 3 mils DFT
4 mils WFT 0.25 gal/100 ft2
Universal Polymers Corp. UPC 2.0 High Lift
(See Note 3) 8 12 4 mils DFT
6 mils WFT 0.38 gal/100 ft2
Universal Polymers Corp. UPC 2.0
(See Note 3) 71/2 111/2 3 mils DFT
4 mils WFT 0.25 gal/100 ft2
Victory Polymers Corp. VPC-50 OCHY
(ESR-4502) 12 12 3 mils DFT
4 mils WFT 0.25 gal/100 ft2
Victory Polymers Inc. VPC-OneStroke
(See Note 3) 71/2 111/2 12 mils DFT
18 mils WFT 1.13 gal/100 ft2
Victory Polymers Inc. VPC-HiR-OC
(See Note 3) 14 14 3 mils DFT
4 mils WFT 0.25 gal/100 ft2
Victory Polymers Inc. VPC-50NF
(ESR-4657) 10 12 4 mils DFT
6 mils WFT 0.38 gal/100 ft2
XtremeSeal, LLC XtremeSeal 0.4 LX
(See Note 3) 8 12 3 mils DFT
4 mils WFT 0.25 gal/100 ft2
XtremeSeal, LLC XtremeSeal 0.5 LX
(See Note 3) 91/2 111/2 3 mils DFT
4 mils WFT 0.25 gal/100 ft2
For SI: 1 inch = 25.4 mm; 1 mil = 0.0254 mm; 1 gallon = 3.38 L; 1 ft2 = 0.93 m2.
Notes:
1DFT = Dry Film Thickness; WFT = Wet Film Thickness
2As reported in the manufacturer’s application instructions. Actual application rate, based upon specific project conditions, must be in accordance with the
manufacturer’s application instructions.
3Recognition is limited to the NFPA 286 test data for the coated assembly described. Evaluation for compliance of the spray foam insulation with other applicable
requirements of AC377 and the IBC and IRC are outside the scope of the report.
ESR-3702 | Most Widely Accepted and Trusted Page 11 of 13
TABLE 3—NFPA 285 COMPLYING EXTERIOR WALL ASSEMBLIES
WALL COMPONENTS MATERIALS
Base wall system —
Use either 1, 2 or 3
1 — Concrete wall
2 — Concrete masonry wall
3 — 1 layer of 5/8-inch-thick Type X gypsum wallboard on interior, installed over minimum 35/8-inch-deep,
minimum No. 20-gage steel studs spaced at a maximum of 24 inches on center with lateral bracing every 4
feet as required by the code.
Floorline firestopping 4 pcf mineral-fiber insulation friction-fit in each wall stud cavity at each floor line. Thickness must match stud
cavity depth.
Cavity insulation—
Use either 1, 2, 3 or 4
1 — None
2 — Spray-applied foam plastic insulation, maximum 35/8-inch-thick of Carlisle SealTite™ Pro (ESR-2072)
applied to Base wall 3, covering the width of the stud cavity and either fully filling the stud cavity depth or partially
filling the stud cavity depth leaving a maximum air space of 15/8 inches. 3 — Fiberglass batt insulation, Class A
(faced or unfaced)1
4 — Mineral -fiber insulation complying with ASTM E1361
Exterior sheathing—
Use 1 with Base Wall 1 or 2, Use
2 with Base Wall 3
1 — None
2 — Minimum 1/2-inch-thick ASTM C1177 complying exterior sheathing
Exterior Insulation
1 — Maximum 31/2-inch-thick of Carlisle SealTite™ Pro Closed Cell (ESR-2072) spray foam insulation, applied
directly to the exterior face of the exterior sheathing of Base wall 3 or directly to the exterior face of Base wall 1 or
2,
2 — The exposed surface of the spray foam insulation must be covered with International Fireproof Technology,
Inc. DC315 intumescent coating applied at a minimum average 16 mils wet film thickness
3 — The DC31 5 coating must be covered with Sherwin-Williams SHER-CRYL HPA topcoat applied at a
minimum average 12 mils wet film thickness2
Exterior wall
covering—Use either
1 through 12
1 — Brick
—Standard nominally 4-inch-thick clay brick with brick veneer anchors installed a maximum of 24 inches on
center vertically on each stud.
Maximum 2-inch air gap between exterior insulation and brick.
2 — Cast concrete – Minimum 1–inch-thick, using any standard non -open-jointed installation.
—Maximum 2-inch air gap between exterior insulation and cast concrete .
3 — Concrete masonry units – Minimum 21/2–inch-thick, using any standard non-open-jointed installation .
— Maximum 2-inch air gap between exterior insulation and concrete masonry units.
4 — Natural stone veneer – Minimum 2-inch-thick, using any standard non-open -jointed installation technique
5 — Terracotta cladding – Use any terracotta cladding system in which the terracotta is minimum 11/4-inch-thick,
using any standard non-open-jointed installation technique.
6 — Stucco – Minimum 3/4 –inch-thick, code-complying three-coat exterior cement plaster and lath.
7 — Aluminum cladding panels, vertical interlocking type – Minimum 0.030-inch-thick using the framing system
specified in footnote 3.
8 — Corrosion -resistant steel cladding panels, interlocking type – minimum 0.0149-inch-thick using the framing
system specified in footnote 3.
9 — Cold -rolled copper cladding panels, interlocking type – minimum 0.0216-inch-thick, minimum 16 ounces per
square foot, using the framing system specified in footnote 3.
10 — Fiber-cement siding – Minimum 0.25 inches thick, using any standard non-open-jointed installation.
11— One-coat Stucco – Minimum thickness as stated in a current ICC-ES evaluation report where the one-coat
stucco has been qualified for compliance under AC11.
12 — Thin brick veneer – Minimum 1/4-inch thick thin brick complying with ASTM C1088, adhered to minimum 3/4
–inch-thick, code-complying three-coat exterior cement plaster and lath mortar bed.
Opening Flashing Minimum 0.030-inch-thick aluminum flashing installed at all openings to completely cover the opening header,
jambs and sill
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pcf = 16.01 kg/m3.
1Insulation must comply with the applicable requirements of 2018, 2015 or 2012 IBC Section 720.2 (2009 IBC Section 719.2).
2Coating must be applied in accordance with the coating manufacturer’s published installation instructions.
3Framing for Exterior wall coverings 7, 8, and 9 consists of minimum 22 gage steel C-channel with 13/8-inch legs (54 mm) installed around the perimeter of any
window opening or door opening through the exterior sheathing to the steel studs. 4-inch deep (101 mm), 20-gage steel Z-girts with
2-inch legs (51 mm) secured through exterior sheathing to studs at 24 inches (610 mm) on-center. Hat Channels [1-inch deep (25.4 mm), 37/8-inch tall (99 mm)]
22-gage steel hat channels fastened at 24 inches (610 mm) on-center to the Z-girts. Z-girts may be installed horizontally or vertically. The cladding edges interlock
together such that all edges and fasteners are concealed after installation. The maximum air space between the exterior face of the spray-applied foam plastic
insulation and the back of the exterior wall covering cladding panels described in 7, 8 and 9 must not exceed 21/2 inches (64 mm).
ESR-3702 | Most Widely Accepted and Trusted Page 12 of 13
1. Steel Studs — See Table 3, Base Wall System 3 (See Alternate Base
Wall in Table 3).
Systems
2. Interior Gypsum Board — See Table 3.
3. Exterior Gypsum Sheathing — See Table 3.
4. Cavity Insulation — See Table 3
5. Exterior Insulation — See Table 3.
6. Exterior Insulation Intumescent Coating — See Table 3, Items 2 and 3.
7. Mounting System — See Table 3.
7A. Z-Girts and Window Channel — See Table 3, Footnote 3.
7B. Hat Channels — See Table 3, Footnote 3.
8. Ext erior Cladding — See Table 3 Claddings 7, 8 or 9.(Other Claddings in
Table 3 are not shown)
10. Floorline Firestopping — See Table 3.
11. Window Flashing — See Table 3, Footnote 3.
FIGURE 1—TABLE 3 (COMPONENTS)*
FIGURE 2—TABLE 3 (WALL DETAILS)*
ESR-3702 | Most Widely Accepted and Trusted Page 13 of 13
FIGURE 3—TABLE 3 (OPENING DETAILS)*
*In the event of conflict between the written descriptions in Table 3 and the Figure, the written description applies.