HomeMy WebLinkAboutEnergy Efficiency Code Building Constructiond
FORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Lot 55 Block 1 Waterstone 1820 AGL Builder Name: ADAMS HOMES
Street: 5339 Lugo Street Permit Office:
City, State, Zip: Fort Pierce , FL , 34951 Permit Number:
Owner: Jurisdiction: 661000
Design Location: FL, ST_LUCIE_CO_INTL County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans) 10. Wall Type> 2120.0 sqft.) Insulation Area
2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1785.00 ftz
b. Frame - Wood, Adjacent R=13.0 270.00 ftz
3. Number of units, if multiple family 1 c. Frame - Wood, Exterior R=13.0 65.00 ftz
4. Number of Bedrooms 4 d. N/A R= ftz
5. Is this a worst case? No 11. Ceiling Types (1900.0 sqft.) Insulation Area
a. Under Attic (Vented) R=30.0 1820.00 ftZ
6. Conditioned floor area above grade (ftz) 1820 b. Knee Wall (Vented) R=19.0 80.00 ft2
Conditioned floor area below grade (ftz) 0 c. N/A R= ftz
7. Windows(239.3 sqft.) . Description Area 12. Ducts R ftz
a. Sup: Attic, Ret: Main, AH: Main 6 364
a. U-Factor: Dbl, U=0.33 136.36 ftz
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.33 32.38 ftz 13. Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.21 a. Central Unit 35.0 SEER:16.00
c. U-Factor: Dbl, U=0.30 32.38 ftz
SHGC: SHGC=0.23
Area Weighted Average Overhang Depth: 4.251 ft. 14. Heating systems kBtu/hr Efficiency
Area Weighted Average SHGC: 0.269 a. Electric Heat Pump 34.6 HSPF:8.50
8. Skylights Area
c. U-Factor:(AVG) N/A ftz 15. Hot water systems
SHGC(AVG): N/A a. Electric Cap: 40 gallons
9. Floor Types (1820.0 sqft.) Insulation Area EF: 0.940
a. Slab -On -Grade Edge Insulation R=0.0 1820.00 ftz b. Conservation features
b. N/A R= ftz None
c. N/A R= ftz 16. Credits Pstat
Glass/Floor Area: 0.131 Total Proposed Modified Loads: 57.89 PASS
Total Baseline Loads: 64.64
I hereby certify that the plans fications covere Rev w of the plans:and ONHF,ST,�
this calculation are in comp' n t e to ' nergy specifications covered by this _ ,p
Code. calculation indicates compliance
with the Florida Energy Code. E• f�iii0.
PREPARED BY: Before construction is completed
y this building will be inspected for
DATE: - t'1A-17-7n71 Winn Kanman
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance Florida Statutes.
with the Florida'Ermrgq-Eede,
OWNER/AGENT: BUILDING OFFICIAL:
DATE: DATE:
= Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
',envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
8/17/2021 9:39 AM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 4
T
FORM R405-2020
INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
Lot 55 Block 1 Waterstone 18 Bedrooms: 4
Address Type:
Street Address
Building Type:
User
Conditioned Area: 1820
Lot #
55-1
Owner Name:
Total Stories: 1
Block/Subdivision:
Waterstone
# of Units:
1
Worst Case: No
PlatBook:
Builder Name:
ADAMS HOMES
Rotate Angle: 0
Street:
5339 Lugo Street
Permit Office:
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
661000
Whole House Fan: No
City, State, Zip:
Fort Pierce ,
Family Type:
Detached
FL, 34951
New/Existing:
New (From Plans)
Comment:
CLIMATE
Design Temp
Int Design Temp
Heating
Design Daily Temp
V
Design Location TMY Site
97.5 % 2.5 %
Winter Summer
Degree Days
Moisture Range
FL, ST LUCIE_CO_INTL FL_VERO_BEACH_MUNI
39 90
70 75
299
58 Medium
BLOCKS
Number Name Area Volume
1
Blockl 1820 18200
SPACES
Number Name Area Volume Kitchen Occupants
Bedrooms InfilID Finished
Cooled Heated
1
Main 1820 18200
Yes 5
4 1
Yes
Yes Yes
FLOORS
# Floor Type Space Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 33 ft 0
1820 ftz ---- 0.42
0 0.58
ROOF
/
Roof
Gable Roof
Rad Solar
SA Emitt
Emitt Deck Pitch
V
# Type Materials Area
Area Color
Barr Absor. Tested
Tested Insul. (deg)
1 Gable or Shed Composition shingles 2035 ftZ
456 ftZ Medium
N 0.85
N 0.85
No 0 26.57
ATTIC
'/
# Type Ventilation
Vent Ratio (1 in)
Area RBS
IRCC
1 Full attic Vented
300 1820 ftz N
N
CEILING
# Ceiling Type Space
R-Value Ins Type Area
Framing Frac
Truss Type
1 Under Attic (Vented) Main
30 Blown
1820 ftZ
0.11
Wood
2 Knee Wall (Vented) Main
19 Blown
80 ftz
0.11
Wood
■
8/17/2021 9:39 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 4
FORM R405-2020
INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Space
Cavity Width
Height
Sheathing Framing
Solar Below
a
1 S
Exterior
Concrete Block - Int Insul
Main
4.1 59
0
10 0
590.0 ft2
0
0
0.6
0
2 E
Exterior
Concrete Block - Int Insul
Main
4.1 13
6
10 0
135.0 ft2
0
0
0.6
0
3 N
Exterior
Concrete Block - Int Insul
Main
4.1 66
0
10 0
660.0 ft2
0
0
0.6
0
4 W
Exterior
Concrete Block - Int Insul
Main
4.1 40
0
10 0
400.0 ft2
0
0.6
0
5 -
Garage
Frame - Wood
Main
13 27
0
10 0
270.0 ft2
0
0.23
0.01
0
6 E
Exterior
Frame - Wood
Main
13 6
6
10
65.0 ft2
0.23
0.6
0
DOORS
#
Ornt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
E
Insulated
Main
None
.25
3
6 8
20 ft2
2
-
Wood
Main
None
.25
2
8
6 8
17.8 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
V
Wall
Overhang
#
Ornt ID
Frame Panes NFRC
U-Factor SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
N
3
Vinyl Low-E Double
Yes
0.33 0.23
N
6.9 ft2
1 ft 4 in
0 ft 10 in
None
Exterior 5
2
S
1
Vinyl Low-E Double
Yes
0.33 0.23
N
48.6 ft2
1 ft 4 in
0 ft 10 in
None
Exterior 5
3
E
6
Vinyl Low-E Double
Yes
0.33 0.31
N
7.1 ft2
9 ft 4 in
0 ft 0 in
None
None
4
E
2
Vinyl Low-E Double
Yes
0.33 0.21
N
16.2 ft2
1 ft 4 in
1 ft 0 in
None
None
5
E
2
Vinyl Low-E Double
Yes
0.33 0.21
N
16.2 ft2
1 ft 4 in
1 ft 0 in
None
Exterior 5
6
E
6
Vinyl Low-E Double
Yes
0.33 0.31
N
13.3 ft2
9 ft 4 in
1 ft 6 in
None
None
7
N
3
Vinyl Low-E Double
Yes
0.33 0.23
N
48.6 ft2
1 ft 4 in
0 ft 10 in
None
Exterior 5
8
W
4
Vinyl Low-E Double
Yes
0.55 0.7
N
17.8 ft2
12 ft 0 in
0 ft 6 in
None
None
9
W
4
Vinyl Low-E Double
Yes
0.3 0.23
N
32.4 ft2
1 ft 4 in
0 ft 10 in
None
Exterior 5
10
W
4
Vinyl Low-E Double
Yes
0.33 0.23
N
32.4 ft2
12 ft 0 in
0 ft 6 in
None
Exterior 5
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
596 ft2 596 ft2
64 ft
8 ft
1
INFILTRATION
# Scope
Method SLA
CFM 50 ELA
EgLA
ACH
ACH 50
1 Wholehouse
Proposed ACH(50) .000444
2123.3 116.49
218.7
.1381
7
8/17/2021 9:39 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 4
FORM R405-2020 INPUT SUMMARY CHFCKI IST RFPnPT
HEATING SYSTEM
# System Type
Subtype
Speed Efficiency
Capacity
Block
Ducts
1 Electric Heat Pump/
Split
Singl HSPF:8.5
34.6 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency
Capacity
Air Flow
SHR
Block
Ducts
1 Central Unit/
Split
Singl SEER: 16 35
kBtu/hr
cfm
0.75
1
sys#1
HOT WATER SYSTEM
# System Type
SubType
Location
EF Cap Use
SetPnt
Conservation
1 Electric
None
Garage
0.94 40 gal 62.3 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert # Company Name
System Model # Collector Model
# Area
Volume
FEF
None None
ft2
DUCTS
/ ---- Supply ----
---- Return ----
Air
CFM 25 CFM25
HVAC #
# Location R-Value Area
Location
Area Leakage Type
Handler
TOT OUT
QN
RLF
Heat Cool
1 Attic
6 364 ft2
Main
91 ft2 Default Leakage
Main
(Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Coolin Jan ] Feb
Heating X Jan f X] Feb
Mar
Mar
Apr
APr
May X Jun X Jul
Mayf lJun f ] Jul
X Au
f J Aug
SeP
rj Se
Oct
Oct
Nov
Nov
Dec
Dec
Ventin [ Jan [ ] Feb
X Mar
[X] A r [
Ma [ Jun [ Jul
[ Au
Se [X]
Oct
X Nov
Dec
Thermostat Schedule: HERS 2006
Reference
Hours
Schedule Type
1
2 3
4 5 6
7
8 9
10
11
12
Cooling (WD) AM
78
78 78
78 78 78
78
78 80
80
80
80
PM
80
80 78
78 78 78
78
78 78
78
78
78
Cooling (WEH) AM
78
78 78
78 78 78
78
78 78
78
78
78
PM
78
78 78
78 78 78
78
78 78
78
78
78
Heating (WD) AM
66
66 66
66 66 68
68
68 68
68
68
68
PM
68
68 68
68 68 68
68
68 68
68
66
66
Heating (WEH) AM
66
66 66
66 66 68
68
68 68
68
68
68
PM
68
68 68
68 68 68
68
68 68
68
66
66
MASS
Mass Type
Area
Thickness Furniture Fraction Space
Default 8 Ibs/s .ft.
0 ft2
0 ft
0.3
Main
8/17/2021 9:39 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 4
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 90
The lower the EnergyPerformance Index, the more efficient the home.
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ft2)
7. Windows- Description
a. U-Factor: Dbl, U=0.33
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.33
SHGC: SHGC=0.21
c. U-Factor: Dbl, U=0.30
SHGC: SHGC=0.23
d. U-Factor: other (see details)
SHGC: other (see details)
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
8. Skylights Description
a. U-Factor(AVG): N/A
SHGC(AVG): N/A
9. Floor Types Insulation
a. Slab -On -Grade Edge Insulation R=0.0
b. N/A R=
c. N/A R=
5339 Lugo Street, Fort Pierce, FL, 34951
New (From Plans)
10. Wall Type and Insulation
Insulation
Area
Detached
a. Concrete Block - Int Insul, Exterior
R=4.1
1785.00 ft2
b. Frame - Wood, Adjacent
R=13.0
270.00 ft2
1
c. Frame - Wood, Exterior
R=13.0
65.00 ft2
4
d. N/A
R=
ft2
No
11. Ceiling Type and insulation level
Insulation
Area
a. Under Attic (Vented)
R=30.0
1820.00 ft2
1820
b. Knee Wall (Vented)
R=19.0
80.00 ft2
Area
c. N/A
R=
ft2
136.36 ft2
12. Ducts, location & insulation level
R ft2
a. Sup: Attic, Ret: Main, AH: Main
6 364
32.38 ft2
13. Cooling systems
kBtu/hr
Efficiency
32.38 ft2
a. Central Unit
35.0 SEER:16.00
38.19 ft2
14. Heating systems
kBtu/hr Efficiency
4.251 ft.
a. Electric Heat Pump
34.6 HSPF:8.50
0.269
Area
15. Hot water systems
ft2
a. Electric
Cap: 40 gallons
EF: 0.94
b. Conservation features
Area
None
1820.00 ft2
Credits (Performance method)
Pstat
ft2
ft2
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature: Date:
Address of New Home: City/FL Zip:
�. *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
8/17/2021 9:39 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1