tnxTower Report - version 8.1.1.0
Date: November 05, 2021
Morrison Hershfield
1455 Lincoln Parkway, Suite 500
Atlanta, GA 30346
(770) 379-8500
Subject: Structural Analysis Report
Carrier Designation: AT&T Mobility Co-Locate
Site Number: 10126637
Site Name: St Lucie Blvd
FA Number: 10126637
Crown Castle Designation: BU Number: 5800245
Site Name: Fox
JDE Job Number: 678972
Work Order Number: 2031568
Order Number: 579723 Rev. 0
Engineering Firm Designation: Morrison Hershfield Project Number: CN7-925R3 / 2200039
Site Data: 5041 St. Lucie Blvd., Fort Pierce, St. Lucie County, FL 34996
Latitude 27° 28' 54.17'', Longitude -80° 22' 32.68''
134 Foot – Sabre Monopole Tower
Morrison Hershfield is pleased to submit this “Structural Analysis Report” to determine the structural integrity
of the above-mentioned tower.
The purpose of the analysis is to determine acceptability of the tower stress level. Based on our analysis we
have determined the tower stress level for the structure and foundation, under the following load case, to be:
LC7: Proposed Equipment Configuration Sufficient Capacity
This analysis utilizes an ultimate 3-second gust wind speed of 158 mph as required by the 2020 Florida Building
Code 7th Edition. Applicable Standard references and design criteria are listed in Section 2 - Analysis Criteria.
Respectfully submitted by:
G. Lance Cooke, P.E. (FL License No. 68787)
Senior Engineer
Certificate of Authorization #8508
November 05, 2021
134 Ft Monopole Tower Structural Analysis CCI BU No 5800245
Project Number CN7-925R3 / 2200039, Order 579723, Revision 0 Page 2
tnxTower Report - version 8.1.1.0
TABLE OF CONTENTS
1) INTRODUCTION
2) ANALYSIS CRITERIA
Table 1 - Proposed Equipment Configuration
Table 2 - Other Considered Equipment
3) ANALYSIS PROCEDURE
Table 3 - Documents Provided
3.1) Analysis Method
3.2) Assumptions
4) ANALYSIS RESULTS
Table 4 - Section Capacity (Summary)
Table 5 – Tower Component Stresses vs. Capacity – LC7
4.1) Recommendations
5) APPENDIX A
tnxTower Output
6) APPENDIX B
Base Level Drawing
7) APPENDIX C
Additional Calculations
November 05, 2021
134 Ft Monopole Tower Structural Analysis CCI BU No 5800245
Project Number CN7-925R3 / 2200039, Order 579723, Revision 0 Page 3
tnxTower Report - version 8.1.1.0
1) INTRODUCTION
This tower is a 134 ft Monopole tower designed by Sabre Communications Corporation.
2) ANALYSIS CRITERIA
TIA-222 Revision: TIA-222-H
Risk Category: II
Wind Speed: 158 mph
Exposure Category: C
Topographic Factor: 1
Service Wind Speed: 60 mph
Table 1 - Proposed Equipment Configuration
Mounting
Level (ft)
Center
Line
Elevation
(ft)
Number
of
Antennas
Antenna
Manufacturer Antenna Model
Number
of Feed
Lines
Feed
Line
Size (in)
132.0
133.0
6 commscope SBNHH-1D85B w/ Mount Pipe
13
4
2
3
3
1-5/8
7/8
3/4
3/8
5/16
3 kathrein 800372965 w/ Mount Pipe
3 ericsson RRUS 4415 B30
3 ericsson RRUS 4449 B5/B12
3 ericsson RRUS 4478 B14_CCIV2
3 ericsson RRUS 8843 B2/B66A_CCIV2
2 raycap DC6-48-60-18-8C-EV
132.0 1 raycap DC6-48-60-18-8F
1 - Platform Mount [LP 303-1]
Table 2 - Other Considered Equipment
Mounting
Level (ft)
Center
Line
Elevation
(ft)
Number
of
Antennas
Antenna
Manufacturer Antenna Model
Number
of Feed
Lines
Feed
Line
Size (in)
120.0 123.0
3 commscope FFHH-65C-R3 w/ Mount Pipe
12 1-5/8
3 ericsson AIR6449 B41_T-MOBILE
w/ Mount Pipe
3 ericsson RADIO 4460 B2/B25 B66_TMO
3 ericsson RADIO 4480 B71_TMO
120.0 1 - Platform Mount [LP 303-1_HR-1]
112.0 112.0
3 jma wireless MX08FRO665-21 w/ Mount Pipe
1 1-1/2
3 fujitsu TA08025-B604
3 fujitsu TA08025-B605
1 raycap RDIDC-9181-PF-48
1 - Commscope MC-PK8-DSH
102.0 102.0
3 kathrein 80010922 w/ Mount Pipe 3
1
6
1
5/8
5/16
1/4
1/8
3 ericsson Radio 4408
1 - Side Arm Mount [SO 202-3]
November 05, 2021
134 Ft Monopole Tower Structural Analysis CCI BU No 5800245
Project Number CN7-925R3 / 2200039, Order 579723, Revision 0 Page 4
tnxTower Report - version 8.1.1.0
3) ANALYSIS PROCEDURE
Table 3 - Documents Provided
Document Reference Source
4-GEOTECHNICAL REPORTS 2609348 CCISITES
4-TOWER FOUNDATION DRAWINGS/DESIGN/SPECS 2604744 CCISITES
4-TOWER MANUFACTURER DRAWINGS 2604731 CCISITES
3.1) Analysis Method
tnxTower (version 8.1.1.0), a commercially available analysis software package, was used to create a
three-dimensional model of the tower and calculate member stresses for various loading cases.
Selected output from the analysis is included in Appendix A. When applicable, Crown Castle has
calculated and provided the effective area for panel antennas using approved methods following the
intent of the TIA-222 standard.
3.2) Assumptions
1) Tower and structures were maintained in accordance with the TIA-222 Standard.
2) The configuration of antennas, transmission cables, mounts and other appurtenances are as
specified in Tables 1 and 2 and the referenced drawings.
This analysis may be affected if any assumptions are not valid or have been made in error. Morrison
Hershfield should be notified to determine the effect on the structural integrity of the tower.
4) ANALYSIS RESULTS
Table 4 - Section Capacity (Summary)
Section
No. Elevation (ft) Component Type Size Critical
Element P (K) SF*P_allow
(K)
%
Capacity Pass / Fail
L1 134 - 96.75 Pole TP27.77x16x0.25 1 -12.88 1279.74 58.0 Pass
L2 96.75 - 47.25 Pole TP42.91x26.0061x0.5 2 -25.76 3949.39 43.2 Pass
L3 47.25 - 0 Pole TP56.84x40.0142x0.5 3 -46.65 5492.11 48.1 Pass
Summary
Pole (L1) 58.0 Pass
Rating = 58.0 Pass
Table 5 - Tower Component Stresses vs. Capacity – LC7
Notes Component Elevation (ft) % Capacity Pass / Fail
1 Anchor Rods 0 44.1 Pass
1 Base Plate 30.4 Pass
1 Base Foundation (Structure) 0 51.3 Pass
1 Base Foundation (Soil Interaction) 21.4 Pass
Structure Rating (max from all components) = 58%*
Notes:
1) See additional documentation in “Appendix C – Additional Calculations” for calculations supporting the % capacity
consumed.
2) *Rating per TIA-222-H, Section 15.5.
November 05, 2021
134 Ft Monopole Tower Structural Analysis CCI BU No 5800245
Project Number CN7-925R3 / 2200039, Order 579723, Revision 0 Page 5
tnxTower Report - version 8.1.1.0
4.1) Recommendations
The tower and its foundation have sufficient capacity to carry the proposed load configuration. No
modifications are required at this time.
November 05, 2021
134 Ft Monopole Tower Structural Analysis CCI BU No 5800245
Project Number CN7-925R3 / 2200039, Order 579723, Revision 0 Page 6
tnxTower Report - version 8.1.1.0
APPENDIX A
TNXTOWER OUTPUT
Consulting Engineers
Morrison Hershfield
1455 Lincoln Parkway, Suite 500
Atlanta, GA 30346
Phone: (770) 379-8500
FAX: (770) 379-8501
Job: CN7-925R3 / 2200039
Project: 5800245 / Fox
Client: Crown Castle USA Drawn by: CKK App'd:
Code: TIA-222-H Date: 11/05/21 Scale: NTS
Path:
X:\Reference\Telecom\US Tower Projects\Crown Analyses-7\CN7-925 - 5800245 - Fox\CN7-925R3 SA\Analysis\CN7-925R3 BU_5800245 WO_2031568.eri
Dwg No. E-1
134.0 ft
96.8 ft
47.3 ft
0.0 ft
REACTIONS - 158 mph WIND
TORQUE 3 kip-ft
40 K
SHEAR
3644 kip-ft
MOMENT
47 K
AXIAL
ARE FACTORED
ALL REACTIONS
Section123 Length (ft)37.2553.5053.25 Number of Sides181818 Thickness (in)0.25000.50000.5000 Socket Length (ft)4.006.00 Top Dia (in)16.000026.006140.0142 Bot Dia (in)27.770042.910056.8400 GradeA572-65 Weight (K)2.29.813.825.8MATERIAL STRENGTH
GRADE GRADEFy FyFu Fu
A572-65 65 ksi 80 ksi
TOWER DESIGN NOTES
1. Tower designed for Exposure C to the TIA-222-H Standard.
2. Tower designed for a 158 mph basic wind in accordance with the TIA-222-H Standard.
3. Deflections are based upon a 60 mph wind.
4. Tower Risk Category II.
5. Topographic Category 1 with Crest Height of 0.00 ft
6. TOWER RATING: 58%
November 05, 2021
134 Ft Monopole Tower Structural Analysis CCI BU No 5800245
Project Number CN7-925R3 / 2200039, Order 579723, Revision 0 Page 7
tnxTower Report - version 8.1.1.0
Tower Input Data
The tower is a monopole.
This tower is designed using the TIA-222-H standard.
The following design criteria apply:
· Tower base elevation above sea level: 19.00 ft.
· Basic wind speed of 158 mph.
· Risk Category II.
· Exposure Category C.
· Simplified Topographic Factor Procedure for wind speed-up calculations is used.
· Topographic Category: 1.
· Crest Height: 0.00 ft.
· Deflections calculated using a wind speed of 60 mph.
· A non-linear (P-delta) analysis was used.
· Pressures are calculated at each section.
· Stress ratio used in pole design is 1.
· Tower analysis based on target reliabilities in accordance with Annex S.
· Load Modification Factors used: Kes(Fw) = 0.95.
· Maximum demand-capacity ratio is: 1.05.
· Local bending stresses due to climbing loads, feed line supports, and appurtenance mounts are not
considered.
Options
Consider Moments - Legs Distribute Leg Loads As Uniform Use ASCE 10 X-Brace Ly Rules
Consider Moments - Horizontals Assume Legs Pinned Calculate Redundant Bracing Forces
Consider Moments - Diagonals √ Assume Rigid Index Plate Ignore Redundant Members in FEA
Use Moment Magnification √ Use Clear Spans For Wind Area SR Leg Bolts Resist Compression
√ Use Code Stress Ratios Use Clear Spans For KL/r All Leg Panels Have Same Allowable
√ Use Code Safety Factors - Guys Retension Guys To Initial Tension Offset Girt At Foundation
Escalate Ice √ Bypass Mast Stability Checks √ Consider Feed Line Torque
Always Use Max Kz √ Use Azimuth Dish Coefficients Include Angle Block Shear Check
Use Special Wind Profile √ Project Wind Area of Appurt. Use TIA-222-H Bracing Resist.
Exemption
Include Bolts In Member Capacity Autocalc Torque Arm Areas Use TIA-222-H Tension Splice
Exemption
Leg Bolts Are At Top Of Section Add IBC .6D+W Combination Poles
Secondary Horizontal Braces Leg Sort Capacity Reports By Component √ Include Shear-Torsion Interaction
Use Diamond Inner Bracing (4 Sided) Triangulate Diamond Inner Bracing Always Use Sub-Critical Flow
SR Members Have Cut Ends Treat Feed Line Bundles As Cylinder Use Top Mounted Sockets
SR Members Are Concentric Ignore KL/ry For 60 Deg. Angle Legs Pole Without Linear Attachments
Pole With Shroud Or No
Appurtenances
Outside and Inside Corner Radii Are
Known
Tapered Pole Section Geometry
Section Elevation
ft
Section
Length
ft
Splice
Length
ft
Number
of
Sides
Top
Diameter
in
Bottom
Diameter
in
Wall
Thickness
in
Bend
Radius
in
Pole Grade
L1 134.00-96.75 37.25 4.00 18 16.0000 27.7700 0.2500 1.0000 A572-65
(65 ksi)
L2 96.75-47.25 53.50 6.00 18 26.0061 42.9100 0.5000 2.0000 A572-65
(65 ksi)
L3 47.25-0.00 53.25 18 40.0142 56.8400 0.5000 2.0000 A572-65
(65 ksi)
November 05, 2021
134 Ft Monopole Tower Structural Analysis CCI BU No 5800245
Project Number CN7-925R3 / 2200039, Order 579723, Revision 0 Page 8
tnxTower Report - version 8.1.1.0
Tapered Pole Properties
Section Tip Dia.
in
Area
in2
I
in4
r
in
C
in
I/C
in3
J
in4
It/Q
in2
w
in
w/t
L1 16.2083 12.4976 391.6752 5.5912 8.1280 48.1884 783.8657 6.2500 2.3760 9.504
28.1598 21.8371 2089.4389 9.7696 14.1072 148.1119 4181.6271 10.9206 4.4475 17.79
L2 27.6135 40.4782 3326.9550 9.0547 13.2111 251.8302 6658.2877 20.2429 3.6971 7.394
43.4948 67.3047 15293.9334 15.0556 21.7983 701.6119 30607.9909 33.6587 6.6722 13.344
L3 42.4795 62.7091 12370.1554 14.0276 20.3272 608.5509 24756.5878 31.3605 6.1625 12.325
57.6397 89.4116 35856.2531 20.0007 28.8747 1241.7870 71759.6868 44.7143 9.1238 18.248
Tower
Elevation
ft
Gusset
Area
(per face)
ft2
Gusset
Thickness
in
Gusset Grade Adjust. Factor
Af
Adjust.
Factor
Ar
Weight Mult.
Double Angle
Stitch Bolt
Spacing
Diagonals
in
Double Angle
Stitch Bolt
Spacing
Horizontals
in
Double Angle
Stitch Bolt
Spacing
Redundants
in
L1 134.00-
96.75
1 1 1
L2 96.75-
47.25
1 1 1
L3 47.25-0.00 1 1 1
Feed Line/Linear Appurtenances - Entered As Round Or Flat
Description Sector Exclude
From
Torque
Calculation
Componen
t
Type
Placement
ft
Total
Number
Number
Per Row
Start/En
d
Position
Width or
Diamete
r
in
Perimete
r
in
Weight
plf
***
Safety Line 3/8 C No Surface Ar
(CaAa)
134.00 -
10.00
1 1 0.000
0.000
0.3750 0.22
Climbing Pegs C No Surface Ar
(CaAa)
134.00 -
10.00
1 1 -0.050
0.050
0.7050 1.80
***
Feed Line/Linear Appurtenances - Entered As Area
Description Face
or
Leg
Allow
Shield
Exclude
From
Torque
Calculation
Componen
t
Type
Placement
ft
Total
Number
CAAA
ft2/ft
Weight
plf
******
LDF7-50A(1-5/8) A No No Inside Pole 132.00 - 8.00 13 No Ice 0.00 0.82
840 10414(5/16) A No No Inside Pole 132.00 - 8.00 3 No Ice 0.00 0.06
WR-VG86ST-
BRD(3/4)
A No No Inside Pole 132.00 - 8.00 2 No Ice 0.00 0.58
***
FB-L98B-034-
XXX(3/8)
A No No Inside Pole 132.00 - 8.00 3 No Ice 0.00 0.06
WR-VG66ST-
BRD_CCIV2(7/8)
A No No Inside Pole 132.00 - 8.00 4 No Ice 0.00 0.88
******
EC7-50A(1-5/8) C No No Inside Pole 120.00 - 3.00 10 No Ice 0.00 0.68
***
HB158-21U6S24-
xxM_TMO(1-5/8)
C No No Inside Pole 120.00 - 3.00 2 No Ice 0.00 2.50
*****
CU12PSM9P6XXX
(1-1/2)
B No No Inside Pole 112.00 - 3.00 1 No Ice 0.00 2.35
*******
RPM1191647(5/8) C No No Inside Pole 102.00 - 8.00 3 No Ice 0.00 0.14
RPM2533512(1/8) C No No Inside Pole 102.00 - 8.00 1 No Ice 0.00 0.02
TFL90134(1/4) C No No Inside Pole 102.00 - 8.00 3 No Ice 0.00 0.00
860 10009(1/4) C No No Inside Pole 102.00 - 8.00 3 No Ice 0.00 0.00
860 10013(5/16) C No No Inside Pole 102.00 - 8.00 1 No Ice 0.00 0.00
***
November 05, 2021
134 Ft Monopole Tower Structural Analysis CCI BU No 5800245
Project Number CN7-925R3 / 2200039, Order 579723, Revision 0 Page 9
tnxTower Report - version 8.1.1.0
Feed Line/Linear Appurtenances Section Areas
Tower
Sectio
n
Tower
Elevation
ft
Face AR
ft2
AF
ft2
CAAA
In Face
ft2
CAAA
Out Face
ft2
Weight
K
L1 134.00-96.75 A
B
C
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
4.023
0.000
0.000
0.000
0.55
0.04
0.35
L2 96.75-47.25 A
B
C
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
5.346
0.000
0.000
0.000
0.78
0.12
0.71
L3 47.25-0.00 A
B
C
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
4.023
0.000
0.000
0.000
0.62
0.10
0.61
Feed Line Center of Pressure
Section Elevation
ft
CPX
in
CPZ
in
CPX
Ice
in
CPZ
Ice
in
L1 134.00-96.75 0.0000 0.8327 0.0000 0.5217
L2 96.75-47.25 0.0000 0.8485 0.0000 0.5259
L3 47.25-0.00 0.0000 0.6580 0.0000 0.4046
Note: For pole sections, center of pressure calculations do not consider feed line shielding.
Shielding Factor Ka
Tower
Section
Feed Line
Record No.
Description Feed Line
Segment
Elev.
Ka
No Ice
Ka
Ice
L1 2 Safety Line 3/8 96.75 -
134.00
1.0000 1.0000
L1 3 Climbing Pegs 96.75 -
134.00
1.0000 1.0000
L2 2 Safety Line 3/8 47.25 -
96.75
1.0000 1.0000
L2 3 Climbing Pegs 47.25 -
96.75
1.0000 1.0000
L3 2 Safety Line 3/8 10.00 -
47.25
1.0000 1.0000
L3 3 Climbing Pegs 10.00 -
47.25
1.0000 1.0000
Discrete Tower Loads
Description Face
or
Leg
Offset
Type
Offsets:
Horz
Lateral
Vert
ft
ft
ft
Azimuth
Adjustmen
t
°
Placement
ft
CAAA
Front
ft2
CAAA
Side
ft2
Weight
K
Lighting Rod 3/4'' x 3' C From Leg 0.00
0.00
1.50
0.0000 134.00 No Ice 0.23 0.23 0.03
*******
DC6-48-60-18-8F C From Leg 4.00
0.00
0.00
0.0000 132.00 No Ice 0.92 0.92 0.02
8' x 2'' Mount Pipe A From Leg 4.00
0.00
0.0000 132.00 No Ice 1.90 1.90 0.03
November 05, 2021
134 Ft Monopole Tower Structural Analysis CCI BU No 5800245
Project Number CN7-925R3 / 2200039, Order 579723, Revision 0 Page 10
tnxTower Report - version 8.1.1.0
Description Face
or
Leg
Offset
Type
Offsets:
Horz
Lateral
Vert
ft
ft
ft
Azimuth
Adjustmen
t
°
Placement
ft
CAAA
Front
ft2
CAAA
Side
ft2
Weight
K
0.00
8' x 2'' Mount Pipe B From Leg 4.00
0.00
0.00
0.0000 132.00 No Ice 1.90 1.90 0.03
8' x 2'' Mount Pipe C From Leg 4.00
0.00
0.00
0.0000 132.00 No Ice 1.90 1.90 0.03
Platform Mount [LP 303-1] B None 0.0000 132.00 No Ice 14.69 14.69 1.25
***
(3) SBNHH-1D85B w/ Mount Pipe A From Leg 4.00
0.00
1.00
0.0000 132.00 No Ice 4.09 3.30 0.07
(3) SBNHH-1D85B w/ Mount Pipe C From Leg 4.00
0.00
1.00
0.0000 132.00 No Ice 4.09 3.30 0.07
(3) 800372965 w/ Mount Pipe B From Leg 4.00
0.00
1.00
0.0000 132.00 No Ice 10.51 6.38 0.11
RRUS 4415 B30 A From Leg 4.00
0.00
1.00
0.0000 132.00 No Ice 1.84 0.82 0.05
RRUS 4415 B30 B From Leg 4.00
0.00
1.00
0.0000 132.00 No Ice 1.84 0.82 0.05
RRUS 4415 B30 C From Leg 4.00
0.00
1.00
0.0000 132.00 No Ice 1.84 0.82 0.05
RRUS 4449 B5/B12 A From Leg 4.00
0.00
1.00
0.0000 132.00 No Ice 1.97 1.41 0.07
RRUS 4449 B5/B12 B From Leg 4.00
0.00
1.00
0.0000 132.00 No Ice 1.97 1.41 0.07
RRUS 4449 B5/B12 C From Leg 4.00
0.00
1.00
0.0000 132.00 No Ice 1.97 1.41 0.07
RRUS 4478 B14_CCIV2 A From Leg 4.00
0.00
1.00
0.0000 132.00 No Ice 2.02 1.25 0.06
RRUS 4478 B14_CCIV2 B From Leg 4.00
0.00
1.00
0.0000 132.00 No Ice 2.02 1.25 0.06
RRUS 4478 B14_CCIV2 C From Leg 4.00
0.00
1.00
0.0000 132.00 No Ice 2.02 1.25 0.06
RRUS 8843 B2/B66A_CCIV2 A From Leg 4.00
0.00
1.00
0.0000 132.00 No Ice 1.98 1.70 0.08
RRUS 8843 B2/B66A_CCIV2 B From Leg 4.00
0.00
1.00
0.0000 132.00 No Ice 1.98 1.70 0.08
RRUS 8843 B2/B66A_CCIV2 C From Leg 4.00
0.00
1.00
0.0000 132.00 No Ice 1.98 1.70 0.08
DC6-48-60-18-8C-EV A From Leg 4.00
0.00
1.00
0.0000 132.00 No Ice 2.74 2.74 0.03
DC6-48-60-18-8C-EV B From Leg 4.00
0.00
1.00
0.0000 132.00 No Ice 2.74 2.74 0.03
******
(2) 8' x 2'' Mount Pipe A From Leg 4.00
0.00
0.00
0.0000 120.00 No Ice 1.90 1.90 0.03
(2) 8' x 2'' Mount Pipe B From Leg 4.00 0.0000 120.00 No Ice 1.90 1.90 0.03
November 05, 2021
134 Ft Monopole Tower Structural Analysis CCI BU No 5800245
Project Number CN7-925R3 / 2200039, Order 579723, Revision 0 Page 11
tnxTower Report - version 8.1.1.0
Description Face
or
Leg
Offset
Type
Offsets:
Horz
Lateral
Vert
ft
ft
ft
Azimuth
Adjustmen
t
°
Placement
ft
CAAA
Front
ft2
CAAA
Side
ft2
Weight
K
0.00
0.00
(2) 8' x 2'' Mount Pipe C From Leg 4.00
0.00
0.00
0.0000 120.00 No Ice 1.90 1.90 0.03
Platform Mount [LP 303-1_HR-1] A None 0.0000 120.00 No Ice 17.09 17.09 1.50
****
FFHH-65C-R3 w/ Mount Pipe A From Leg 4.00
0.00
3.00
0.0000 120.00 No Ice 12.97 6.20 0.16
FFHH-65C-R3 w/ Mount Pipe B From Leg 4.00
0.00
3.00
0.0000 120.00 No Ice 12.97 6.20 0.16
FFHH-65C-R3 w/ Mount Pipe C From Leg 4.00
0.00
3.00
0.0000 120.00 No Ice 12.97 6.20 0.16
AIR6449 B41_T-MOBILE w/
Mount Pipe
A From Leg 4.00
0.00
3.00
0.0000 120.00 No Ice 5.19 2.71 0.13
AIR6449 B41_T-MOBILE w/
Mount Pipe
B From Leg 4.00
0.00
3.00
0.0000 120.00 No Ice 5.19 2.71 0.13
AIR6449 B41_T-MOBILE w/
Mount Pipe
C From Leg 4.00
0.00
3.00
0.0000 120.00 No Ice 5.19 2.71 0.13
RADIO 4460 B2/B25 B66_TMO A From Leg 4.00
0.00
3.00
0.0000 120.00 No Ice 2.14 1.69 0.11
RADIO 4460 B2/B25 B66_TMO B From Leg 4.00
0.00
3.00
0.0000 120.00 No Ice 2.14 1.69 0.11
RADIO 4460 B2/B25 B66_TMO C From Leg 4.00
0.00
3.00
0.0000 120.00 No Ice 2.14 1.69 0.11
RADIO 4480 B71_TMO A From Leg 4.00
0.00
3.00
0.0000 120.00 No Ice 2.85 1.38 0.09
RADIO 4480 B71_TMO B From Leg 4.00
0.00
3.00
0.0000 120.00 No Ice 2.85 1.38 0.09
RADIO 4480 B71_TMO C From Leg 4.00
0.00
3.00
0.0000 120.00 No Ice 2.85 1.38 0.09
******
MX08FRO665-21 w/ Mount Pipe A From Leg 4.00
0.00
0.00
0.0000 112.00 No Ice 8.01 4.23 0.11
MX08FRO665-21 w/ Mount Pipe B From Leg 4.00
0.00
0.00
0.0000 112.00 No Ice 8.01 4.23 0.11
MX08FRO665-21 w/ Mount Pipe C From Leg 4.00
0.00
0.00
0.0000 112.00 No Ice 8.01 4.23 0.11
TA08025-B605 A From Leg 4.00
0.00
0.00
0.0000 112.00 No Ice 1.96 1.13 0.08
TA08025-B605 B From Leg 4.00
0.00
0.00
0.0000 112.00 No Ice 1.96 1.13 0.08
TA08025-B605 C From Leg 4.00
0.00
0.00
0.0000 112.00 No Ice 1.96 1.13 0.08
TA08025-B604 A From Leg 4.00
0.00
0.00
0.0000 112.00 No Ice 1.96 0.98 0.06
November 05, 2021
134 Ft Monopole Tower Structural Analysis CCI BU No 5800245
Project Number CN7-925R3 / 2200039, Order 579723, Revision 0 Page 12
tnxTower Report - version 8.1.1.0
Description Face
or
Leg
Offset
Type
Offsets:
Horz
Lateral
Vert
ft
ft
ft
Azimuth
Adjustmen
t
°
Placement
ft
CAAA
Front
ft2
CAAA
Side
ft2
Weight
K
TA08025-B604 B From Leg 4.00
0.00
0.00
0.0000 112.00 No Ice 1.96 0.98 0.06
TA08025-B604 C From Leg 4.00
0.00
0.00
0.0000 112.00 No Ice 1.96 0.98 0.06
RDIDC-9181-PF-48 A From Leg 4.00
0.00
0.00
0.0000 112.00 No Ice 2.01 1.17 0.02
(2) 8' x 2'' Mount Pipe A From Leg 4.00
0.00
0.00
0.0000 112.00 No Ice 1.90 1.90 0.03
(2) 8' x 2'' Mount Pipe B From Leg 4.00
0.00
0.00
0.0000 112.00 No Ice 1.90 1.90 0.03
(2) 8' x 2'' Mount Pipe C From Leg 4.00
0.00
0.00
0.0000 112.00 No Ice 1.90 1.90 0.03
Commscope MC-PK8-DSH A None 0.0000 112.00 No Ice 34.24 34.24 1.75
******
80010922 w/ Mount Pipe A From Leg 2.00
0.00
0.00
0.0000 102.00 No Ice 1.61 1.27 0.03
80010922 w/ Mount Pipe B From Leg 2.00
0.00
0.00
0.0000 102.00 No Ice 1.61 1.27 0.03
80010922 w/ Mount Pipe C From Leg 2.00
0.00
0.00
0.0000 102.00 No Ice 1.61 1.27 0.03
Radio 4408 A From Leg 2.00
0.00
0.00
0.0000 102.00 No Ice 0.60 0.33 0.01
Radio 4408 B From Leg 2.00
0.00
0.00
0.0000 102.00 No Ice 0.60 0.33 0.01
Radio 4408 C From Leg 2.00
0.00
0.00
0.0000 102.00 No Ice 0.60 0.33 0.01
Side Arm Mount [SO 202-3] A None 0.0000 102.00 No Ice 5.70 5.70 0.33
****
Load Combinations
Comb.
No.
Description
1 Dead Only
2 1.2 Dead+1.0 Wind 0 deg - No Ice
3 0.9 Dead+1.0 Wind 0 deg - No Ice
4 1.2 Dead+1.0 Wind 30 deg - No Ice
5 0.9 Dead+1.0 Wind 30 deg - No Ice
6 1.2 Dead+1.0 Wind 60 deg - No Ice
7 0.9 Dead+1.0 Wind 60 deg - No Ice
8 1.2 Dead+1.0 Wind 90 deg - No Ice
9 0.9 Dead+1.0 Wind 90 deg - No Ice
10 1.2 Dead+1.0 Wind 120 deg - No Ice
11 0.9 Dead+1.0 Wind 120 deg - No Ice
12 1.2 Dead+1.0 Wind 150 deg - No Ice
13 0.9 Dead+1.0 Wind 150 deg - No Ice
14 1.2 Dead+1.0 Wind 180 deg - No Ice
15 0.9 Dead+1.0 Wind 180 deg - No Ice
16 1.2 Dead+1.0 Wind 210 deg - No Ice
17 0.9 Dead+1.0 Wind 210 deg - No Ice
November 05, 2021
134 Ft Monopole Tower Structural Analysis CCI BU No 5800245
Project Number CN7-925R3 / 2200039, Order 579723, Revision 0 Page 13
tnxTower Report - version 8.1.1.0
Comb.
No.
Description
18 1.2 Dead+1.0 Wind 240 deg - No Ice
19 0.9 Dead+1.0 Wind 240 deg - No Ice
20 1.2 Dead+1.0 Wind 270 deg - No Ice
21 0.9 Dead+1.0 Wind 270 deg - No Ice
22 1.2 Dead+1.0 Wind 300 deg - No Ice
23 0.9 Dead+1.0 Wind 300 deg - No Ice
24 1.2 Dead+1.0 Wind 330 deg - No Ice
25 0.9 Dead+1.0 Wind 330 deg - No Ice
26 Dead+Wind 0 deg - Service
27 Dead+Wind 30 deg - Service
28 Dead+Wind 60 deg - Service
29 Dead+Wind 90 deg - Service
30 Dead+Wind 120 deg - Service
31 Dead+Wind 150 deg - Service
32 Dead+Wind 180 deg - Service
33 Dead+Wind 210 deg - Service
34 Dead+Wind 240 deg - Service
35 Dead+Wind 270 deg - Service
36 Dead+Wind 300 deg - Service
37 Dead+Wind 330 deg - Service
Maximum Member Forces
Sectio
n
No.
Elevation
ft
Component
Type
Condition Gov.
Load
Comb.
Axial
K
Major Axis
Moment
kip-ft
Minor Axis
Moment
kip-ft
L1 134 - 96.75 Pole Max Tension 1 0.00 0.00 0.00
Max. Compression 4 -12.97 -230.27 398.30
Max. Mx 8 -12.91 -477.09 -10.09
Max. My 14 -12.95 -10.34 -466.10
Max. Vy 8 23.30 -477.09 -10.09
Max. Vx 14 23.01 -10.34 -466.10
Max. Torque 4 -3.21
L2 96.75 -
47.25
Pole Max Tension 1 0.00 0.00 0.00
Max. Compression 4 -25.81 -854.31 1481.15
Max. Mx 8 -25.77 -1750.26 -24.89
Max. My 14 -25.79 -25.05 -1725.31
Max. Vy 8 30.62 -1750.26 -24.89
Max. Vx 14 30.32 -25.05 -1725.31
Max. Torque 4 -3.01
L3 47.25 - 0 Pole Max Tension 1 0.00 0.00 0.00
Max. Compression 4 -46.65 -1774.58 3077.46
Max. Mx 8 -46.65 -3618.58 -41.17
Max. My 14 -46.65 -41.13 -3578.29
Max. Vy 8 39.41 -3618.58 -41.17
Max. Vx 14 39.12 -41.13 -3578.29
Max. Torque 4 -3.01
Maximum Reactions
Location Condition Gov.
Load
Comb.
Vertical
K
Horizontal, X
K
Horizontal, Z
K
Pole Max. Vert 8 46.67 -39.38 -0.30
Max. Hx 20 46.67 39.38 0.30
Max. Hz 2 46.67 0.30 39.09
Max. Mx 2 3576.97 0.30 39.09
Max. Mz 8 3618.58 -39.38 -0.30
Max. Torsion 16 3.00 19.43 -33.71
Min. Vert 17 35.01 19.43 -33.71
Min. Hx 8 46.67 -39.38 -0.30
Min. Hz 14 46.67 -0.30 -39.09
November 05, 2021
134 Ft Monopole Tower Structural Analysis CCI BU No 5800245
Project Number CN7-925R3 / 2200039, Order 579723, Revision 0 Page 14
tnxTower Report - version 8.1.1.0
Location Condition Gov.
Load
Comb.
Vertical
K
Horizontal, X
K
Horizontal, Z
K
Min. Mx 14 -3578.29 -0.30 -39.09
Min. Mz 20 -3617.33 39.38 0.30
Min. Torsion 4 -3.00 -19.43 33.71
Tower Mast Reaction Summary
Load
Combination
Vertical
K
Shearx
K
Shearz
K
Overturning
Moment, Mx
kip-ft
Overturning
Moment, Mz
kip-ft
Torque
kip-ft
Dead Only 38.90 0.00 0.00 0.53 -0.50 0.00
1.2 Dead+1.0 Wind 0 deg -
No Ice
46.67 -0.30 -39.09 -3576.97 39.90 2.99
0.9 Dead+1.0 Wind 0 deg -
No Ice
35.01 -0.30 -39.09 -3554.48 39.75 2.98
1.2 Dead+1.0 Wind 30 deg -
No Ice
46.67 19.43 -33.71 -3077.46 -1774.58 3.00
0.9 Dead+1.0 Wind 30 deg -
No Ice
35.01 19.43 -33.71 -3058.16 -1763.20 3.00
1.2 Dead+1.0 Wind 60 deg -
No Ice
46.67 33.96 -19.29 -1753.08 -3113.69 2.21
0.9 Dead+1.0 Wind 60 deg -
No Ice
35.01 33.96 -19.29 -1742.19 -3093.78 2.21
1.2 Dead+1.0 Wind 90 deg -
No Ice
46.67 39.38 0.30 41.17 -3618.58 0.84
0.9 Dead+1.0 Wind 90 deg -
No Ice
35.01 39.38 0.30 40.69 -3595.44 0.84
1.2 Dead+1.0 Wind 120 deg
- No Ice
46.67 34.25 19.80 1824.49 -3154.07 -0.75
0.9 Dead+1.0 Wind 120 deg
- No Ice
35.01 34.25 19.80 1812.72 -3133.85 -0.75
1.2 Dead+1.0 Wind 150 deg
- No Ice
46.67 19.95 34.00 3119.16 -1844.67 -2.14
0.9 Dead+1.0 Wind 150 deg
- No Ice
35.01 19.95 34.00 3099.21 -1832.75 -2.14
1.2 Dead+1.0 Wind 180 deg
- No Ice
46.67 0.30 39.09 3578.29 -41.13 -2.96
0.9 Dead+1.0 Wind 180 deg
- No Ice
35.01 0.30 39.09 3555.46 -40.65 -2.96
1.2 Dead+1.0 Wind 210 deg
- No Ice
46.67 -19.43 33.71 3078.76 1773.35 -3.00
0.9 Dead+1.0 Wind 210 deg
- No Ice
35.01 -19.43 33.71 3059.13 1762.29 -3.00
1.2 Dead+1.0 Wind 240 deg
- No Ice
46.67 -33.96 19.29 1754.39 3112.45 -2.24
0.9 Dead+1.0 Wind 240 deg
- No Ice
35.01 -33.96 19.29 1743.16 3092.87 -2.23
1.2 Dead+1.0 Wind 270 deg
- No Ice
46.67 -39.38 -0.30 -39.86 3617.33 -0.86
0.9 Dead+1.0 Wind 270 deg
- No Ice
35.01 -39.38 -0.30 -39.71 3594.51 -0.86
1.2 Dead+1.0 Wind 300 deg
- No Ice
46.67 -34.25 -19.80 -1823.17 3152.83 0.75
0.9 Dead+1.0 Wind 300 deg
- No Ice
35.01 -34.25 -19.80 -1811.74 3132.94 0.75
1.2 Dead+1.0 Wind 330 deg
- No Ice
46.67 -19.95 -34.00 -3117.83 1843.44 2.16
0.9 Dead+1.0 Wind 330 deg
- No Ice
35.01 -19.95 -34.00 -3098.22 1831.84 2.16
Dead+Wind 0 deg - Service 38.90 -0.04 -5.31 -483.82 4.96 0.40
Dead+Wind 30 deg - Service 38.90 2.64 -4.58 -416.19 -240.69 0.41
Dead+Wind 60 deg - Service 38.90 4.61 -2.62 -236.89 -421.99 0.30
Dead+Wind 90 deg - Service 38.90 5.35 0.04 6.03 -490.36 0.12
Dead+Wind 120 deg -
Service
38.90 4.65 2.69 247.48 -427.47 -0.10
Dead+Wind 150 deg - 38.90 2.71 4.62 422.77 -250.18 -0.29
November 05, 2021
134 Ft Monopole Tower Structural Analysis CCI BU No 5800245
Project Number CN7-925R3 / 2200039, Order 579723, Revision 0 Page 15
tnxTower Report - version 8.1.1.0
Load
Combination
Vertical
K
Shearx
K
Shearz
K
Overturning
Moment, Mx
kip-ft
Overturning
Moment, Mz
kip-ft
Torque
kip-ft
Service
Dead+Wind 180 deg -
Service
38.90 0.04 5.31 484.92 -6.00 -0.40
Dead+Wind 210 deg -
Service
38.90 -2.64 4.58 417.29 239.65 -0.41
Dead+Wind 240 deg -
Service
38.90 -4.61 2.62 237.99 420.95 -0.30
Dead+Wind 270 deg -
Service
38.90 -5.35 -0.04 -4.93 489.32 -0.12
Dead+Wind 300 deg -
Service
38.90 -4.65 -2.69 -246.38 426.43 0.10
Dead+Wind 330 deg -
Service
38.90 -2.71 -4.62 -421.67 249.15 0.29
Solution Summary
Load
Comb.
Sum of Applied Forces Sum of Reactions
% Error PX
K
PY
K
PZ
K
PX
K
PY
K
PZ
K
1 0.00 -38.90 0.00 0.00 38.90 0.00 0.000%
2 -0.30 -46.67 -39.09 0.30 46.67 39.09 0.000%
3 -0.30 -35.01 -39.09 0.30 35.01 39.09 0.000%
4 19.43 -46.67 -33.71 -19.43 46.67 33.71 0.000%
5 19.43 -35.01 -33.71 -19.43 35.01 33.71 0.000%
6 33.96 -46.67 -19.29 -33.96 46.67 19.29 0.000%
7 33.96 -35.01 -19.29 -33.96 35.01 19.29 0.000%
8 39.38 -46.67 0.30 -39.38 46.67 -0.30 0.000%
9 39.38 -35.01 0.30 -39.38 35.01 -0.30 0.000%
10 34.25 -46.67 19.80 -34.25 46.67 -19.80 0.000%
11 34.25 -35.01 19.80 -34.25 35.01 -19.80 0.000%
12 19.95 -46.67 34.00 -19.95 46.67 -34.00 0.000%
13 19.95 -35.01 34.00 -19.95 35.01 -34.00 0.000%
14 0.30 -46.67 39.09 -0.30 46.67 -39.09 0.000%
15 0.30 -35.01 39.09 -0.30 35.01 -39.09 0.000%
16 -19.43 -46.67 33.71 19.43 46.67 -33.71 0.000%
17 -19.43 -35.01 33.71 19.43 35.01 -33.71 0.000%
18 -33.96 -46.67 19.29 33.96 46.67 -19.29 0.000%
19 -33.96 -35.01 19.29 33.96 35.01 -19.29 0.000%
20 -39.38 -46.67 -0.30 39.38 46.67 0.30 0.000%
21 -39.38 -35.01 -0.30 39.38 35.01 0.30 0.000%
22 -34.25 -46.67 -19.80 34.25 46.67 19.80 0.000%
23 -34.25 -35.01 -19.80 34.25 35.01 19.80 0.000%
24 -19.95 -46.67 -34.00 19.95 46.67 34.00 0.000%
25 -19.95 -35.01 -34.00 19.95 35.01 34.00 0.000%
26 -0.04 -38.90 -5.31 0.04 38.90 5.31 0.000%
27 2.64 -38.90 -4.58 -2.64 38.90 4.58 0.000%
28 4.61 -38.90 -2.62 -4.61 38.90 2.62 0.000%
29 5.35 -38.90 0.04 -5.35 38.90 -0.04 0.000%
30 4.65 -38.90 2.69 -4.65 38.90 -2.69 0.000%
31 2.71 -38.90 4.62 -2.71 38.90 -4.62 0.000%
32 0.04 -38.90 5.31 -0.04 38.90 -5.31 0.000%
33 -2.64 -38.90 4.58 2.64 38.90 -4.58 0.000%
34 -4.61 -38.90 2.62 4.61 38.90 -2.62 0.000%
35 -5.35 -38.90 -0.04 5.35 38.90 0.04 0.000%
36 -4.65 -38.90 -2.69 4.65 38.90 2.69 0.000%
37 -2.71 -38.90 -4.62 2.71 38.90 4.62 0.000%
November 05, 2021
134 Ft Monopole Tower Structural Analysis CCI BU No 5800245
Project Number CN7-925R3 / 2200039, Order 579723, Revision 0 Page 16
tnxTower Report - version 8.1.1.0
Non-Linear Convergence Results
Load
Combination
Converged? Number
of Cycles
Displacement
Tolerance
Force
Tolerance
1 Yes 4 0.00000001 0.00000001
2 Yes 4 0.00000001 0.00035888
3 Yes 4 0.00000001 0.00022121
4 Yes 5 0.00000001 0.00009472
5 Yes 5 0.00000001 0.00004073
6 Yes 5 0.00000001 0.00008111
7 Yes 5 0.00000001 0.00003429
8 Yes 4 0.00000001 0.00024166
9 Yes 4 0.00000001 0.00014626
10 Yes 5 0.00000001 0.00009036
11 Yes 5 0.00000001 0.00003791
12 Yes 5 0.00000001 0.00009714
13 Yes 5 0.00000001 0.00004116
14 Yes 4 0.00000001 0.00054209
15 Yes 4 0.00000001 0.00033218
16 Yes 5 0.00000001 0.00007952
17 Yes 5 0.00000001 0.00003363
18 Yes 5 0.00000001 0.00009316
19 Yes 5 0.00000001 0.00003993
20 Yes 4 0.00000001 0.00006997
21 Yes 4 0.00000001 0.00004121
22 Yes 5 0.00000001 0.00009360
23 Yes 5 0.00000001 0.00003949
24 Yes 5 0.00000001 0.00008673
25 Yes 5 0.00000001 0.00003634
26 Yes 4 0.00000001 0.00001107
27 Yes 4 0.00000001 0.00001899
28 Yes 4 0.00000001 0.00001137
29 Yes 4 0.00000001 0.00000535
30 Yes 4 0.00000001 0.00001226
31 Yes 4 0.00000001 0.00001737
32 Yes 4 0.00000001 0.00001169
33 Yes 4 0.00000001 0.00001250
34 Yes 4 0.00000001 0.00001709
35 Yes 4 0.00000001 0.00000489
36 Yes 4 0.00000001 0.00001389
37 Yes 4 0.00000001 0.00001206
Maximum Tower Deflections - Service Wind
Section
No.
Elevation
ft
Horz.
Deflection
in
Gov.
Load
Comb.
Tilt
°
Twist
°
L1 134 - 96.75 9.217 30 0.6912 0.0070
L2 100.75 - 47.25 4.896 30 0.4917 0.0014
L3 53.25 - 0 1.293 30 0.2309 0.0004
Critical Deflections and Radius of Curvature - Service Wind
Elevation
ft
Appurtenance Gov.
Load
Comb.
Deflection
in
Tilt
°
Twist
°
Radius of
Curvature
ft
134.00 Lighting Rod 3/4'' x 3' 30 9.217 0.6912 0.0070 47635
132.00 DC6-48-60-18-8F 30 8.939 0.6791 0.0066 47635
120.00 (2) 8' x 2'' Mount Pipe 30 7.290 0.6066 0.0043 17012
112.00 MX08FRO665-21 w/ Mount Pipe 30 6.243 0.5586 0.0029 10826
102.00 80010922 w/ Mount Pipe 30 5.036 0.4991 0.0015 7544
November 05, 2021
134 Ft Monopole Tower Structural Analysis CCI BU No 5800245
Project Number CN7-925R3 / 2200039, Order 579723, Revision 0 Page 17
tnxTower Report - version 8.1.1.0
Maximum Tower Deflections - Design Wind
Section
No.
Elevation
ft
Horz.
Deflection
in
Gov.
Load
Comb.
Tilt
°
Twist
°
L1 134 - 96.75 67.807 10 5.0632 0.0516
L2 100.75 - 47.25 36.095 10 3.6254 0.0105
L3 53.25 - 0 9.541 10 1.7039 0.0026
Critical Deflections and Radius of Curvature - Design Wind
Elevation
ft
Appurtenance Gov.
Load
Comb.
Deflection
in
Tilt
°
Twist
°
Radius of
Curvature
ft
134.00 Lighting Rod 3/4'' x 3' 10 67.807 5.0632 0.0517 6621
132.00 DC6-48-60-18-8F 10 65.765 4.9764 0.0488 6621
120.00 (2) 8' x 2'' Mount Pipe 10 53.677 4.4558 0.0315 2363
112.00 MX08FRO665-21 w/ Mount Pipe 10 45.990 4.1097 0.0214 1502
102.00 80010922 w/ Mount Pipe 10 37.128 3.6790 0.0114 1045
Compression Checks
Pole Design Data
Section
No.
Elevation
ft
Size
L
ft
Lu
ft
Kl/r
A
in2
Pu
K
fPn
K
Ratio
Pu
fPn
L1 134 - 96.75 (1) TP27.77x16x0.25 37.25 0.00 0.0 20.8342 -12.88 1218.80 0.011
L2 96.75 - 47.25 (2) TP42.91x26.0061x0.5 53.50 0.00 0.0 64.2961 -25.76 3761.32 0.007
L3 47.25 - 0 (3) TP56.84x40.0142x0.5 53.25 0.00 0.0 89.4116 -46.65 5230.58 0.009
Pole Bending Design Data
Section
No.
Elevation
ft
Size
Mux
kip-ft
fMnx
kip-ft
Ratio
Mux
fMnx
Muy
kip-ft
fMny
kip-ft
Ratio
Muy
fMny
L1 134 - 96.75 (1) TP27.77x16x0.25 482.97 813.50 0.594 0.00 813.50 0.000
L2 96.75 - 47.25 (2) TP42.91x26.0061x0.5 1765.31 3962.03 0.446 0.00 3962.03 0.000
L3 47.25 - 0 (3) TP56.84x40.0142x0.5 3643.76 7348.56 0.496 0.00 7348.56 0.000
Pole Shear Design Data
Section
No.
Elevation
ft
Size
Actual
Vu
K
fVn
K
Ratio
Vu
fVn
Actual
Tu
kip-ft
fTn
kip-ft
Ratio
Tu
fTn
L1 134 - 96.75 (1) TP27.77x16x0.25 23.50 365.64 0.064 0.75 840.75 0.001
L2 96.75 - 47.25 (2) TP42.91x26.0061x0.5 30.81 1128.40 0.027 0.75 4003.59 0.000
L3 47.25 - 0 (3) TP56.84x40.0142x0.5 39.59 1569.17 0.025 0.75 7742.26 0.000
November 05, 2021
134 Ft Monopole Tower Structural Analysis CCI BU No 5800245
Project Number CN7-925R3 / 2200039, Order 579723, Revision 0 Page 18
tnxTower Report - version 8.1.1.0
Pole Interaction Design Data
Section
No.
Elevation
ft
Ratio
Pu
fPn
Ratio
Mux
fMnx
Ratio
Muy
fMny
Ratio
Vu
fVn
Ratio
Tu
fTn
Comb.
Stress
Ratio
Allow.
Stress
Ratio
Criteria
L1 134 - 96.75 (1) 0.011 0.594 0.000 0.064 0.001 0.609 1.050 4.8.2
L2 96.75 - 47.25 (2) 0.007 0.446 0.000 0.027 0.000 0.453 1.050 4.8.2
L3 47.25 - 0 (3) 0.009 0.496 0.000 0.025 0.000 0.505 1.050 4.8.2
Section Capacity Table
Section
No.
Elevation
ft
Component
Type
Size Critical
Element
P
K
øPallow
K
%
Capacity
Pass
Fail
L1 134 - 96.75 Pole TP27.77x16x0.25 1 -12.88 1279.74 58.0 Pass
L2 96.75 - 47.25 Pole TP42.91x26.0061x0.5 2 -25.76 3949.39 43.2 Pass
L3 47.25 - 0 Pole TP56.84x40.0142x0.5 3 -46.65 5492.11 48.1 Pass
Summary
Pole (L1) 58.0 Pass
RATING = 58.0 Pass
November 05, 2021
134 Ft Monopole Tower Structural Analysis CCI BU No 5800245
Project Number CN7-925R3 / 2200039, Order 579723, Revision 0 Page 19
tnxTower Report - version 8.1.1.0
APPENDIX B
BASE LEVEL DRAWING
November 05, 2021
134 Ft Monopole Tower Structural Analysis CCI BU No 5800245
Project Number CN7-925R3 / 2200039, Order 579723, Revision 0 Page 20
tnxTower Report - version 8.1.1.0
APPENDIX C
ADDITIONAL CALCULATIONS
Monopole Base Plate Connection
*TIA-222-H Section 15.5 Applied
#VALUE!
Anchor Rod Data Anchor Rod Summary (units of kips, kip-in)
(24) 2-1/4" ø bolts (A615-75 N; Fy=75 ksi, Fu=100 ksi) on 63.5" BC Pu_t = 112.76 φPn_t = 243.75 Stress Rating
Anchor Spacing: 6 in Vu = 1.65 φVn = 149.1 44.1%
Mu = n/a φMn = n/a Pass
Base Plate Data
66.5" W x 3" Plate (A572-50; Fy=50 ksi, Fu=65 ksi); Clip: 17 in Base Plate Summary
Max Stress (ksi):14.36 (Flexural)
Stiffener Data Allowable Stress (ksi):45
N/A Stress Rating:30.4%Pass
Pole Data
56.84" x 0.5" 18-sided pole (A572-65; Fy=65 ksi, Fu=80 ksi)
46.65
39.59
Adjusted Pole Reactions
BU # 5800245
Applied Loads
Site Name Fox
Order # 579723 Rev. 0
Analysis Considerations
Site Info
TIA-222 Revision H
Grout Considered:No
Analysis ResultsConnection Properties
Iar (in) 1
Moment (kip-ft) 3643.75
Axial Force (kips) 46.65
Shear Force (kips) 39.59
Moment (kip-ft)
Axial Force (kips)
Shear Force (kips)
0.00
Analysis Date: 11/5/2021CCIplate - Version 4.1.2
Report File:
TIA-222 Revison:
Tower Type:Check Pier Capacity only at location of Max Moment?No
Location:
Soil Lateral Check Compression Uplift
Comp.Uplift 10.21 -
3643.75 7.59 -
46.67 3973.73 -
39.56 16.7% -
Soil Vertical Check Compression Uplift Go to Soil Calculations
868.62 -
3 ksi 173.18 -
60 ksi 186.89 -
40 ksi 1041.80 -
233.56 -
21.4%-
40 ft Reinforced Concrete Flexure Compression Uplift
0.5 ft 10.29 -
3973.69 -
8323.16 -
7 ft 45.5% -
27 36 Reinforced Concrete Shear Compression Uplift
11 29.34 -
4 in 286.68 -
5 532.59 -
in 51.3% -
in
*Rating per TIA-222-H Section 15.5
7.5 # of Layers 4
121
FALSE 1 0 3.5 3.5 120 150 0 0 0.000 0.000 0.00 0.00
FALSE 2 3.5 7.5 4 120 150 0 30 0.781 0.781 19
FALSE 3 7.5 18 10.5 58 87.6 0 30 1.063 1.063 13
FALSE 4 18 40 22 68 87.6 0 34 1.745 1.745 6 46
Pier Diameter
Rebar Quantity
Rebar Cage Diameter
Rebar Quantity
Tie Spacing
Drilled Pier Foundation
BU # :
Site Name:
Order Number:
Monopole
Applied Loads
Material Properties
Pier Design Data
H
5800245
Fox
579723 Rev. 0
Moment (kip-ft)
Axial Force (kips)
Shear Force (kips)
Concrete Strength, f'c:
Rebar Strength, Fy:
Tie Yield Strength, Fyt:
Cohesionless
Cohesionless
Cohesionless
Ultimate Skin
Friction Uplift
Override (ksf)
Critical Shear Capacity
Rating*
Skin Friction (kips)
Weight of Concrete (kips)
Rating*
Critical Shear (kip)
End Bearing (kips)
Axial (kips)
Critical Depth (ft from TOC)
Calculated
Ultimate Skin
Friction Uplift
(ksf)
Calculated
Ultimate Skin
Friction Comp
(ksf)
Ultimate Skin
Friction Comp
Override
(ksf)
Soil Profile
Soil TypeSPT Blow
Count
Ult. Gross
Bearing
Capacity
(ksf)
γsoil
(pcf)
γconcrete
(pcf)
Critical Depth (ft from TOC)
21.4%Soil Interaction Rating*
Rebar 2, Fy
Override
(ksi)
Rebar 3, Fy
Override
(ksi)
Depth
Cohesionless
Layer Top
(ft)Bottom (ft)Thickness
(ft)
Groundwater Depth
Cohesion
(ksf)
Angle of
Friction
(degrees)
Rebar Size
Pier Section 1
Check Limitation
Apply TIA-222-H Section 15.5:
Additional Longitudinal Rebar
Shear Design Options
Check Shear along Depth of Pier:
Utilize Shear-Friction Methodology:
Override Critical Depth:
Dv=0 (ft from TOC)
Soil Safety Factor
Max Moment (kip-ft)
Rating*
Ext. Above Grade
Critical Moment (kip-ft)
Critical Moment Capacity
Rating*
From 0.5' above grade to 40' below grade
Rebar Size
Clear Cover to Ties
Tie Size
Input Effective Depths (else Actual):
X:\Reference\Telecom\US Tower Projects\Crown Analyses-7\CN7-925 - 5800245 - Fox\CN7-925R3 SA\Analysis\CN7-925R3 BU_5800245 WO_2031568.eri.rtf
51.3%Structural Foundation Rating*
Total Capacity (kips)
N/A
Analysis Results
Rebar!&!Pier!Options
Embedded!Pole!Inputs
Belled!Pier!Inputs
Version 5.0.3
ASCE 7 Hazards Report
Address:
No Address at This
Location
Standard:ASCE/SEI 7-16
Risk Category:II
Soil Class:D - Default (see
Section 11.4.3)
Elevation:18.54 ft (NAVD 88)
Latitude:
Longitude:
27.481714
-80.375744
Wind
Results:
Wind Speed: 158 Vmph
10-year MRI 87 Vmph
25-year MRI 106 Vmph
50-year MRI 118 Vmph
100-year MRI 130 Vmph
Data Source: ASCE/SEI 7-16, Fig. 26.5-1B and Figs. CC.2-1–CC.2-4, and Section 26.5.2
Date Accessed: Fri Nov 05 2021
Value provided is 3-second gust wind speeds at 33 ft above ground for Exposure C Category, based on linear
interpolation between contours. Wind speeds are interpolated in accordance with the 7-16 Standard. Wind speeds
correspond to approximately a 7% probability of exceedance in 50 years (annual exceedance probability =
0.00143, MRI = 700 years).
Site is in a hurricane-prone region as defined in ASCE/SEI 7-16 Section 26.2. Glazed openings shall be protected
against wind-borne debris as specified in Section 26.12.3.
Page 1 of 3https://asce7hazardtool.online/Fri Nov 05 2021
SS : 0.05
S1 : 0.028
F a : 1.6
F v : 2.4
SMS : 0.08
SM1 : 0.068
SDS : 0.053
SD1 : 0.045
T L : 8
PGA : 0.023
PGA M : 0.037
F PGA : 1.6
Ie : 1
C v : 0.7
Design Response Spectrum
S (g) vs T(s)a
MCE Response SpectrumR
S (g) vs T(s)a
Design Vertical Response Spectrum
S (g) vs T(s)a
MCE Vertical Response SpectrumR
S (g) vs T(s)a
Seismic
Site Soil Class:
Results:
Seismic Design Category
D - Default (see Section 11.4.3)
A
Data Accessed:
Date Source:
Fri Nov 05 2021
USGS Seismic Design Maps based on ASCE/SEI 7-16 and ASCE/SEI 7-16
Table 1.5-2. Additional data for site-specific ground motion procedures in
accordance with ASCE/SEI 7-16 Ch. 21 are available from USGS.
Page 2 of 3https://asce7hazardtool.online/Fri Nov 05 2021
Ice
Results:
Data Source:
Date Accessed:
Ice Thickness: 0.00 in.
Concurrent Temperature: 25 F
Gust Speed: 30 mph
Standard ASCE/SEI 7-16, Figs. 10-2 through 10-8
Fri Nov 05 2021
Ice thicknesses on structures in exposed locations at elevations higher than the surrounding terrain and in valleys
and gorges may exceed the mapped values.
Values provided are equivalent radial ice thicknesses due to freezing rain with concurrent 3-second gust speeds,
for a 500-year mean recurrence interval, and temperatures concurrent with ice thicknesses due to freezing rain.
Thicknesses for ice accretions caused by other sources shall be obtained from local meteorological studies. Ice
thicknesses in exposed locations at elevations higher than the surrounding terrain and in valleys and gorges may
exceed the mapped values.
The ASCE 7 Hazard Tool is provided for your convenience, for informational purposes only, and is provided “as is” and without warranties of
any kind. The location data included herein has been obtained from information developed, produced, and maintained by third party providers;
or has been extrapolated from maps incorporated in the ASCE 7 standard. While ASCE has made every effort to use data obtained from
reliable sources or methodologies, ASCE does not make any representations or warranties as to the accuracy, completeness, reliability,
currency, or quality of any data provided herein. Any third-party links provided by this Tool should not be construed as an endorsement,
affiliation, relationship, or sponsorship of such third-party content by or from ASCE.
ASCE does not intend, nor should anyone interpret, the results provided by this Tool to replace the sound judgment of a competent
professional, having knowledge and experience in the appropriate field(s) of practice, nor to substitute for the standard of care required of such
professionals in interpreting and applying the contents of this Tool or the ASCE 7 standard.
In using this Tool, you expressly assume all risks associated with your use. Under no circumstances shall ASCE or its officers, directors,
employees, members, affiliates, or agents be liable to you or any other person for any direct, indirect, special, incidental, or consequential
damages arising from or related to your use of, or reliance on, the Tool or any information obtained therein. To the fullest extent permitted by
law, you agree to release and hold harmless ASCE from any and all liability of any nature arising out of or resulting from any use of data
provided by the ASCE 7 Hazard Tool.
Page 3 of 3https://asce7hazardtool.online/Fri Nov 05 2021