Loading...
HomeMy WebLinkAbout5800245_579723_Rev.0_MountAnalysis_Pass_AT&T_132ft_10.29.2021_ES&SDate: October 29, 2021 USA Engineering, Inc. 2818 Cypress Ridge Blvd., Suite 110 Wesley Chapel, FL 33544 (813) 994-0365 Subject: Mount Analysis Report Carrier Designation: AT&T LTE 5C Carrier Site Number: 10126637 Carrier Site Name: ST LUCIE BLVD Carrier FA Number: 10126637 Crown Castle Designation: Crown Castle BU Number: 5800245 Crown Castle Site Name: Fox Crown Castle JDE Job Number: 678972 Crown Castle Order Number: 579723, Rev. 0 Engineering Firm Designation: USA Engineering Designation: ST LUCIE BLVD_10126637 Site Data: 5041 St. Lucie Blvd, Fort Pierce, St. Lucie County, FL, 34996 Latitude 27° 28’ 54.17” Longitude -80° 22’ 32.68” Structure Information: Tower Height & Type: 134 ft Monopole Mount Elevation: 132 ft Mount Type: 12.5 ft Low Profile Mount USA Engineering is pleased to submit this “Mount Analysis Report” to determine the structural integrity of AT&T’s antenna mounting system with the proposed appurtenance and equipment addition on the above mentioned supporting tower structure. Analysis of the existing supporting tower structure is to be completed by others and therefore is not part of this analysis. Analysis of the antenna mounting system as a tie-off point for fall protection or rigging is not part of this document. The purpose of the analysis is to determine acceptability of the mount stress level. Based on our analysis we have determined the mount stress level to be: Low Profile Mount Sufficient This analysis utilizes an ultimate 3-second gust wind speed of 158 mph as required by the 2020 Florida Building Code 7th Edition. Applicable Standard references and design criteria are listed in Section 2 - Analysis Criteria." Mount structural analysis prepared by: Jad Bitar, EI Respectfully Submitted by: Marc Maier, PE FL PE No: 72513 COA No: 31705 This item has been electronically signed and sealed by Marc P. Maier, P.E., FL License #72513 using a Digital Signature. Printed Copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Nov 01 2021 October 29, 2021 12.5 ft Low Profile Mount Analysis Report CCI BU No 5800245 Order 579723, Revision 0 Page 2 ENG-FRM-10208, Rev. D TABLE OF CONTENTS 1) INTRODUCTION 2) ANALYSIS CRITERIA Table 1 - Final Equipment Configuration 3) ANALYSIS PROCEDURE Table 2 - Documents Provided 3.1) Analysis Method 3.2) Assumptions 4) ANALYSIS RESULTS Table 3 - Mount Component Stresses vs. Capacity 4.1) Recommendations 5) APPENDIX A Wire Frame and Rendered Models 6) APPENDIX B Software Input Calculations 7) APPENDIX C Software Analysis Output 8) APPENDIX D Additional Calculations October 29, 2021 12.5 ft Low Profile Mount Analysis Report CCI BU No 5800245 Order 579723, Revision 0 Page 3 ENG-FRM-10208, Rev. D 1) INTRODUCTION This is an existing 3-sector 12.5’ Low Profile Mount. 2) ANALYSIS CRITERIA Building Code: 2020 Florida Building Code 7th Edition TIA-222 Revision: TIA-222-H Risk Category: II Ultimate Wind Speed: 158 mph Exposure Category: C Ice Thickness: 0 in Wind Speed with Ice: 30 mph Seismic Ss: 0.05 Seismic S1: 0.028 Live Loading Wind Speed: 30 mph Man Live Load at Mid/End-Points: 250 lb Man Live Load at Mount Pipes: 250 lb Table 1 - Final Equipment Configuration Mount Centerline (ft) Antenna Centerline (ft) Number of Antennas Antenna Manufacturer Antenna Model Mount / Modification Details 132 133 6 COMMSCOPE SBNHH-1D85B 12.5’ Low Profile Mount 3 KATHREIN 800372965 3 ERICSSON RRUS 4415 B30 3 ERICSSON RRUS 4449 B5/B12 3 ERICSSON RRUS 4478 B14_CCIV2 3 ERICSSON RRUS 8843 B2/B66A_CCIV2 2 RAYCAP DC6-48-60-18-8C-EV 132 1 RAYCAP DC6-48-60-18-8F 3) ANALYSIS PROCEDURE Table 2 - Documents Provided Document Remarks Reference Source RFDS - - CCI Site Structural Analysis Report - Dated 08/24/21 Morrison Hershfield Antenna Mount Pictures - Dated 02/24/21 CCI Site 3.1) Analysis Method RISA-3D (Version 17.0.4), a commercially available analysis software package, was used to create a three-dimensional model of the antenna mounting system and calculate member stresses for various loading cases. A tool internally developed, using Microsoft Excel, by USA Engineering was used to calculate wind loading on all appurtenances, dishes, and mount members for various load cases. Selected output from the analysis is included in Appendix B. October 29, 2021 12.5 ft Low Profile Mount Analysis Report CCI BU No 5800245 Order 579723, Revision 0 Page 4 ENG-FRM-10208, Rev. D This analysis was performed in accordance with Crown Castle’s ENG-SOW-10208 Mount Analysis (Revision D). In addition, this analysis is in accordance with AT&T Mount Technical Guidance ATT-002-291-373. 3.2) Assumptions 1) The antenna mounting system was properly fabricated, installed and maintained in good condition in accordance with its original design and manufacturer's specifications. 2) The configuration of antennas, mounts, and other appurtenances are as specified in Table 1 and the referenced drawings. 3) All member connections are assumed to have been designed to meet or exceed the load carrying capacity of the connected member unless otherwise specified in this report. 4) Steel grades have been assumed as follows, unless noted otherwise: Channel, Solid Round, Angle, Plate ASTM A36 (GR 36) HSS (Rectangular) ASTM 500 (GR B-46) Pipe ASTM A53 (GR 35) Connection Bolts ASTM A325 5) The structure and all components are assumed to be plumb, in good condition; and free from deformation, rust, corrosion, and cracks. 6) The supporting documents and drawings provided to USA Engineering, Inc. resemble the actual field conditions. 7) Dimensions and sizes were assumed based on the pictures. Contractor should verify all measurements prior to construction. This analysis may be affected if any assumptions are not valid or have been made in error. USA Engineering should be notified to determine the effect on the structural integrity of the antenna mounting system. 4) ANALYSIS RESULTS Table 3 - Mount Component Stresses vs. Capacity (Low Profile Mount) Notes Component Critical Member Centerline (ft) % Capacity Pass / Fail 1,4 Antenna Pipe B3 133 89.5 Pass 1,4 Support Tube M9 132 38.9 Pass 2,4 Tower Connection - 132 68.3 Pass Structure Rating (max from all components) = 89.5% Notes: 1) See additional documentation in "Appendix C - Software Analysis Output" for calculations supporting the % capacity consumed 2) See additional documentation in “Appendix D – “Additional Calculations” supporting the % capacity consumed 3) All sectors are typical 4) A structure rating of 105% or less is within engineering tolerances and considered acceptable 4.1) Recommendations The mount has sufficient capacity to carry the proposed loading configuration. No modifications are required at this time. October 29, 2021 12.5 ft Low Profile Mount Analysis Report CCI BU No 5800245 Order 579723, Revision 0 Page 5 ENG-FRM-10208, Rev. D APPENDIX A WIRE FRAME AND RENDERED MODELS 12.5 ft Low Profile Mount Analysis Report Order 579723, Revision 0 October 29, 2021 CCI BU No 5800245 Page 11 ENG-FRM-10208, Rev. D APPENDIX B SOFTWARE INPUT CALCULATIONS ASCE 7 Hazards Report Address: 5041 St Lucie Blvd Fort Pierce, Florida 34946 Standard:ASCE/SEI 7-16 Risk Category:II Soil Class:D - Default (see Section 11.4.3) Elevation:18.53 ft (NAVD 88) Latitude: Longitude: 27.483907 -80.375343 Wind Results: Wind Speed: 158 Vmph 10-year MRI 87 Vmph 25-year MRI 106 Vmph 50-year MRI 118 Vmph 100-year MRI 130 Vmph Data Source: ASCE/SEI 7-16, Fig. 26.5-1B and Figs. CC.2-1–CC.2-4, and Section 26.5.2 Date Accessed: Wed Oct 27 2021 Value provided is 3-second gust wind speeds at 33 ft above ground for Exposure C Category, based on linear interpolation between contours. Wind speeds are interpolated in accordance with the 7-16 Standard. Wind speeds correspond to approximately a 7% probability of exceedance in 50 years (annual exceedance probability = 0.00143, MRI = 700 years). Site is in a hurricane-prone region as defined in ASCE/SEI 7-16 Section 26.2. Glazed openings shall be protected against wind-borne debris as specified in Section 26.12.3. Page 1 of 3https://asce7hazardtool.online/Wed Oct 27 2021 SS : 0.05 S1 : 0.028 F a : 1.6 F v : 2.4 SMS : 0.08 SM1 : 0.068 SDS : 0.053 SD1 : 0.045 T L : 8 PGA : 0.023 PGA M : 0.037 F PGA : 1.6 Ie : 1 C v : 0.7 Design Response Spectrum S (g) vs T(s)a MCE Response SpectrumR S (g) vs T(s)a Design Vertical Response Spectrum S (g) vs T(s)a MCE Vertical Response SpectrumR S (g) vs T(s)a Seismic Site Soil Class: Results: Seismic Design Category D - Default (see Section 11.4.3) A Data Accessed: Date Source: Wed Oct 27 2021 USGS Seismic Design Maps based on ASCE/SEI 7-16 and ASCE/SEI 7-16 Table 1.5-2. Additional data for site-specific ground motion procedures in accordance with ASCE/SEI 7-16 Ch. 21 are available from USGS. Page 2 of 3https://asce7hazardtool.online/Wed Oct 27 2021 The ASCE 7 Hazard Tool is provided for your convenience, for informational purposes only, and is provided “as is” and without warranties of any kind. The location data included herein has been obtained from information developed, produced, and maintained by third party providers; or has been extrapolated from maps incorporated in the ASCE 7 standard. While ASCE has made every effort to use data obtained from reliable sources or methodologies, ASCE does not make any representations or warranties as to the accuracy, completeness, reliability, currency, or quality of any data provided herein. Any third-party links provided by this Tool should not be construed as an endorsement, affiliation, relationship, or sponsorship of such third-party content by or from ASCE. ASCE does not intend, nor should anyone interpret, the results provided by this Tool to replace the sound judgment of a competent professional, having knowledge and experience in the appropriate field(s) of practice, nor to substitute for the standard of care required of such professionals in interpreting and applying the contents of this Tool or the ASCE 7 standard. In using this Tool, you expressly assume all risks associated with your use. Under no circumstances shall ASCE or its officers, directors, employees, members, affiliates, or agents be liable to you or any other person for any direct, indirect, special, incidental, or consequential damages arising from or related to your use of, or reliance on, the Tool or any information obtained therein. To the fullest extent permitted by law, you agree to release and hold harmless ASCE from any and all liability of any nature arising out of or resulting from any use of data provided by the ASCE 7 Hazard Tool. Page 3 of 3https://asce7hazardtool.online/Wed Oct 27 2021 Design Parameters Site Name : 0.95 158 No - - C Zg : 900 -H1 :- 133 α' :9.5 -H2 :- Kz min : 0.85 -Ks : 1.00 Kz max : 2.01 Kz :1.34 -Ke : 1.00 1 Flat/Rolling Terrain Kt : -A Gh : 1.00 -f : -134 Kd : 0.95 -Kc : - -Kh : - -Kzt : 1.00 77.5 (F)lat (HSS) (R)ound Position 1, 3 & 4 - Antenna (Alpha & Gamma) SBNHH-1D85B FRONT 1 F 72.9 11.9 -2.906 0.90 6.13 1.36 2.91 2.62 2.62 2.62 203 SBNHH-1D85B SIDE 1 F 72.9 7.1 -2.368 0.90 10.27 1.51 2.37 2.13 2.13 2.13 165 Position 1, 3 & 4 - Antenna (Beta) 800372965 FRONT 1 F 78.72 14.9 --0.90 5.28 1.32 10.78 9.70 9.70 9.70 752 800372965 SIDE 1 F 78.72 6.5 --0.90 12.11 1.57 5.58 5.02 5.02 5.02 389 Position 1 - RRUS RRUS 4415 B30 FRONT 1 F 16.5 13.4 --0.90 1.23 1.20 1.84 1.66 1.66 1.66 129 RRUS 4415 B30 SIDE 1 F 16.5 5.9 --0.90 2.80 1.21 0.82 0.74 0.74 0.74 57 Position 3 - RRUS RRUS 4449 B5/B12 FRONT 1 F 17.9 9.44 --0.90 1.90 1.20 1.41 1.27 1.27 RRUS 8843 B2/B66A FRONT 1 F 18 11.3 --0.90 1.59 1.20 1.70 1.53 2.79 2.79 216 RRUS 4449 B5/B12 SIDE 1 F 17.9 13.19 --0.90 1.36 1.20 1.97 1.77 1.77 RRUS 8843 B2/B66A SIDE 1 F 18 13.2 --0.90 1.36 1.20 1.98 1.78 3.55 3.55 275 Position 4 - RRUS RRUS 4478 B14 FRONT 1 F 18.10 13.4 --0.90 1.35 1.20 2.02 2.02 2.02 RRUS 32 B2 FRONT 0 F 27.2 7 --0.90 3.89 1.26 1.67 0.00 2.02 2.02 157 RRUS 4478 B14 SIDE 1 F 18.10 8.26 --0.90 2.19 1.20 1.25 1.25 1.25 RRUS 32 B2 SIDE 0 F 27.2 12.1 --0.90 2.25 1.20 2.74 0.00 1.25 1.25 97 DC6-48-60-18-8C DC6-48-60-18-8C FRONT 1 R 31.41 11 --0.90 2.86 168 0.51 1.22 1.22 1.22 1.22 85 DC6-48-60-18-8C SIDE 1 R 31.41 11 --0.90 2.86 168 0.51 1.22 1.22 1.22 1.22 85 0.90 Member Width or Dia. (in)(F)lat / (HSS) / (R)ound (HSS) Thickness (in)UDL (lb/ft) 0 30 45 60 90 2.88 R -20 203 194 184 175 165 2.38 R -17 752 661 571 480 389 0.75 R -5 129 111 93 75 57 0.625 F -7 216 231 246 260 275 3.5 R -24 157 142 127 111 96 6 F -70 85 85 85 85 85 4 HSS 0.25 29 2 F -23 - Dish Type: P / PR / CS / G FRONT SIDE FRONT SIDE FRONT SIDE FRONT SIDE DC6-48-60-18-8C 2.6.11.2 Antenna Loads at Varying θ Position 1, 3 & 4 - Antenna (Alpha & Gamma) Position 1, 3 & 4 - Antenna (Beta) Position 1 - RRUS Position 3 - RRUS Position 4 - RRUS Annex C: Design Wind Force on Typical Microwave Antennas Description θ (°)Diameter (in)CA / CS FAM / FSM (lb) Description FA (lb)Ka θ (°) Uniform Distributed Load Ca for Element EPA per Element (ft2) (EPA)A (ft2) = Σ(CaAa)A FA (lb) Total (ft2)Σ (cum.)Σ (for elev.) 2.6.11.2 Design Wind Load on Appurtenances Description # of Items Element Height (in) Element Width or Dia. (in) (HSS) Thickness (in) Wind-Tunnel EPA (Override) (ft2) Ka Aspect Ratio (AR)C (Round only)rs (HSS only) x (ft), distance from the crest (Site-Specific) : qz = 0.00256 Kz Kzt Ks Ke Kd V2 (psf) : zs (ft), mean elevation of base of structure above sea level : 2.6.6 Topographic Effects Topographic Category, 1, 2, 3, 4 or Site-Specific :2.6.9 Gust Effect Factor Topographic Feature (Site-Specific) :Structure: (M)onopole, (S)elf-support, (G)uyed, (A)ppurtenance : z (ft), height AGL at the base of the structure : h (ft), height of structure from base (only affects Gh for SS) : H (ft), height of crest above surrounding terrain : L (ft), distance to the crest from surrounding terrain (Site-Specific) : 2.6.11.6 Velocity Pressure Exposure Category, B, C or D : Ws (ft), width of windward side of building : z (ft), AGL elevation of discrete appurtenance :Xb (ft), horizontal distance from windward face to center of structure : H (ft), height of parapet : 2.6.8 Ground Elevation Factor V (mph), Basic Ultimate Wind Speed, 3-second gust : Structures/Appurtenances supported on enclosed buildings : zr (ft), height of structure above rooftop : 2.6.5 Exposure Category and Velocity Pressure Coefficient Hs (ft), height of windward side of building : TIA-222-H : Design Wind Force on Appurtenances Annex S: Analysis of Existing Antenna Supporting Structures St. Lucie Blvd_10126637 Kes / Fw 2.6.4 Basic Wind Speed and Design Ice Thickness 2.6.7 Rooftop Wind Speed-Up Factor Wind Loading (Rev. H) (REV.2.1) Beta 1 of 1 10/29/2021 2:29 PM Design Parameters Structure Risk Category II Structure Height (ft)134 Importance Factor, I 1.00 Mount Rad Center (ft)132 Amplification Factor, As 1.00 Short Periods, SS 0.05 Period of 1 Second, S1 0.028 Dead Load of Structures and Appurtenances, D (lb)2784 Long-Period Transition Period, TL 8 Dead Load of Guy Assemblies, Dg (lb)0 Fundamental Period of Structure, T 0.279 Short-period Site Coefficients, Fa 1.6 Long-period Site Coefficients, Fv 2.4 Design spectral response acceleration parameters at short periods, SDS 0.053 Design spectral response acceleration parameters at a period of 1 second, SD1 0.045 2.7.6 Vertical Seismic Load Effect Vertical Seismic Load Effect, Ev (lb) = 0.2 SDS (D + Dg) =29.51 2.7.7 Horizontal Seismic Load Effect Redundancy Factor, ρ 1.00 Total Weight, W (lb)2784 Seismic Response Coefficient, Cs 0.03 2 83.52 83.52 Note: Seismic loads do not control. Horizontal Seismic Load Effect, Eh (lb) = ρ QE Total Seismic Shear Force, Vs TIA-222-H : 2.7 Seismic Load Effects 2.7.4 Seismic Design Parameters Table 2-3: Importance Factors 2.7.5 Design Spectral Response Acceleration Parameters 2.7.8.1 Amplification Factor Effects of Horizontal Seismic Forces, QE 83.52 Loads Response Modification Coefficient, R Seismic Loading (Rev. H) (REV.1.0) Seismic Loading 1 of 1 10/29/2021 2:31 PM 12.5 ft Low Profile Mount Analysis Report Order 579723, Revision 0 October 29, 2021 CCI BU No 5800245 Page 17 ENG-FRM-10208, Rev. D APPENDIX C SOFTWARE ANALYSIS OUTPUT 12.5 ft Low Profile Mount Analysis Report Order 579723, Revision 0 October 29, 2021 CCI BU No 5800245 Page 47 ENG-FRM-10208, Rev. D APPENDIX D ADDITIONAL CALCULATIONS Project Name: St. Lucie Blvd_10126637 Date: 10/29/2021 Engineer: JB Antenna Mount Model:Mount Member:M9 LC:31 DESIGN PARAMETERS:RESULTS: Reactions Shear Bolt Capacity y (k)2.094 Design Capacity, Vult (k)12.40 z (k)0.016 Required Capacity, Vmax (k)0.74 x (k)-0.135 6.0%PASS Mz (k-ft)6.229 My (k-ft)0.026 Mx (k-ft)0.387 Tensile Bolt Capacity (per bolt) Design Capacity, Tult (k)20.70 Required Capacity, Tmax (k)6.29 Bolt Design 30.4%PASS Diameter (in)5/8 Material Group A Thread Cond. / Loading Group A - N / S Bearing Strength at Bolt Holes Number of Bolts 4 Design Bearing Strength, ΦRn (k)24.47 Bolt Spacing (in)6 3.0%PASS Edge Distance (in)1 Clear Distance, Ic (in)0.625 Combined Tensile & Shear (Tmax / Tult)2 + (Vmax / Vult)2 ≤ 1.0 0.10 Connected Element Design - Flange Plate 9.6%PASS Thickness, t (in)0.75 Length of Plate, L (in)8 Specified Min. Yield Stress, Fy (ksi)36 Plate Stress Specified Min. Tensile Strength, Fu (ksi)58 Required Stress (ksi)22.13 Design Stress (ksi)32.4 68.3%PASS Connected Element Design - Tube Width (in)4 Tower Connection Calculations