Loading...
HomeMy WebLinkAboutAPPROVED SOLIS EQUIPMENT DATA SHEETSF�OPra VARIABLE -SPEED PUMP Save up to 90% on energy costs with the VS RoPro 2.7 HP Variable -Speed Pump VS Flo Pro is designed to save you money. Its variable -speed motor allows for dramatic energy savings, especially when operated at lower speeds. In addition, its innovative adjustable base allows for simple installation on new construction, or quick and easy replacement of existing pumps. >) Ultra high -efficiency motor Features a totally enclosed fan -cooled (TEFC) permanent magnet brushless DC motor for cooler operation and extended motor life. Quiet Advanced motor design allows VS FloPro to run at energy -saving tower speeds for significantly quieter operation. » Digital controller included' Two timed speeds/eight speeds total. Remotely mounted controller provides easy access to pump controls. Reliable battery backup ensures time and settings are stored during power outages, >> Compact High-performance pump in a compact body. Fits easily in small equipment areas. >> Additional features • Adjustable base included' • 2" unions and 2" internal threads • Ergonomic easy -transport handle • High profile easy -grip handles with large capacity basket >> Complies with Appliance Efficiency Standards (CEC Title 20 & ANSIQ/APSP-15) and qualifies for utility rebates, where offered. Zodiac Pool Systems, Inc. MEMO 2620 Commerce Way, Vista, CA 92081 i 1.800.822.7933 1 www.ZodiacPooLSystems.com ............................... ....-...-..................................... ................................ Zodiac Pool Systems Canada, Inc. 2115 South Service Road West, Unit 1l3, Oakville, ON L6L 5W2 1.688.647.4004 1 www.2odiacPoolSystems.ca VS FLOPRO 2.70 HP VARIABLE -SPEED PUMP BASE CONFIGURATIONS Config. Model No. Base Incl.? Lines Up to ::'�•^� YSFHP270jEP y Hayward'5uper Pump' No base Pentalrr SuperFlor required VSFHP27DAUL Y I Sta-Rite"SuperMax` F - - VSFHP27GJEP Y r Hayward 5uperll' Small base -..-..-- Jandy Pro Series Plus HP ■nil VSFHP270AUT N 8 Max HP i Small Prase VSFHP270JEP Y Pentair WhisperFlo;' wlspacers Sta-RNeDDyna-Gas VSFHP270AUT N Small base+ VSFHP270JEP Y large ba se- VSFHP27DAUT N DIMENSIONS Sta-Rile Max-E-Pro.' Sta-RiteDura-Glass" � NMI Sfa-RiteOura-Glasll. I 1 � Sta-Rite Max-E-Glas" � 10 7r Few Edge d U.m,n Center o1 Bad Holes Total Norse- Re<oevnended Carton Overall Model No. power Voltage Max Watts Pipe Size' Weight Length VSFHP2701EP 2.7 208 230 VAC 2 600 W 2'h-3- U [t 27e/u VSFHP270AUT` 2.70 208-230 VAC 2,400 W 2!,_-3- WO1b}}s Y,.- PERFORMANCE '- VSFHP270PERFORMANCE CURVES I u_ 0 to w l.L _ �J5a RPM W w x U a � xsoo Rent oW � _esaa Rev le O rmal>tu a . m a n n ® nl ae m em n0 'm tin '.0 no try 'M no � FLOW RATE, GALLONS PER MINUTE, (GPM) Up to 7D% quieter than traditional single -speed pumps. ' Actual savings dependent on pump horsepower, usage and energy costs. Does not include adjustable bases or user interface. Intended for use with Aqua Link RS, Aqua Link PDA, or Aqua Link Z4 control systems. ,Optional: Part It R0546400 ' Always follow local building and safely codes for pipe sizing and guidelines. 02015 Zodiac Pool Systems, Inc. SL6201 Rev F 0415 NSF u ZODIAC* is a registered trademark of Zodiac International. S.A. S.U.. used under ONlicense. ALL other trademarks used herein am the property of their respective owners. MOUNTING THE SENSORS Make sure that the arrows of each sensor are pointed towards each other. Using either the double -sided tape or the screws provided, mount the sensors so that they are less than inch away from each other. Sensors must be mounted flush in height and depth, so with some doors or windows, special custom fitting may be necessary. Please make sure that the wired portion of the magnetic sensor is mounted on the non-moving portion of the mounting surface and the standalone sensor is mounted on the door/gate, (See Fig. 5)Fig. 6) MOUNTING OUTDOORS ON WOODEN GATES Using the provided mounting template printed in this manual, mark the position of the screw holes on the fiAiEii desired mounting surface. Unit the screws onto the mounting surface with approximalely V8 inch of thread remaining. Slide the unit over the screws and Fie 5 secure the unit by pushing it downward as shown in Fig, 5, You may need to adjust the screws towards or away from the mounting surface to provide a more secure Tit. Make sure that the arrows of each sensor are pointed in the same direction. Note: Wooden gates do not require the sensor housings. MouHnxe 3 ounworea ON WOODEN MOUNTING MOUNTING OUTDOORS ON METAL GATES Using the provided zip ties, attach the alarm body tc the metal gale frame. (See Fig. 8) Using a small flat head screwdriver, gently pry open the recessed sensor spacer of the sensor housing. ( Fig .6) Make sure that the arrows of h f d' I oumooas so MOUNTING OUTDOORS ON METAL GATES Using the provided zip ties, attach the alarm body tc the metal gale frame. (See Fig. 8) Using a small flat head screwdriver, gently pry open the recessed sensor spacer of the sensor housing. ( Fig .6) Make sure that the arrows of h f d' I oumooas so ON M�EAATIIRL GATE6II i sensor are pem e m e same direction as the sensor rip. t; housing before placing the magnetic sensors inside the sensor housing. Nate: Metal gales may interfere with the magnetic sensor function- Use spacers provided to ensure sensors operate properly. Secure the sensors using the zip ties onto the gale frame. Make sure that the sensors' arrows are pointed towards each usher and that the sensors are less than %a inch apart. MAINT`� -- - - E�ANiCE When the alarm volume becomes low, or the unit does not produce normal alarm sound, the red light will illuminate, you must replace the 9-volt battery. The Safe Pool's plastic parts resists ultraviolet rays from direct sunlight exposure. However, slight discoloration over time is normal. WARNING! THE SAFE POOL ALARM IS EXTREMELY LOUD WHEN ACTIVATED. FOR YOUR SAFETY, NEVER PLACE THE UNIT CLOSE TO YOUR EARS. TO TEST THE ALARM, At -WAYS USE EAR PROTECTION AND DIRECT THE UNIT AWAY BEFORE TESTINGIAGTIVATING THE ALARM. IT IS PROHIBITED 8Y LAW TO REMOVE THE INSTALLED ALARM AFTER IT HAS PASSED INSPECTION 1 Important Warranty Information: A dated proof of purchase Is required for warranty service Customer Service 1-888-8TECH KD(i -888-883-24 56 ) Website: www.techkomaid.com Mfg. By TDCfMg 9767 Research Drive, Irvine, CA92618-0626 MADE IN CHINA aip- 9700 127 COMPLIES WITH UL2pi7 USA patent: No. 5,473,310 No. 6,727,819 NOTICE THIS PRODUCT IS PROTECTED UNDER FEDERAL PATENT, TRAOEMARKAND COPYRIGHT LAWS AND LAWS PREVENTING UNFAIR COMPETITION. NO DUPLICATION OR SIMULATION OF THIS PRODUCT I5 PERMITTED EXCEPT BY WRITTEN AUTHORIZATION OF TECHKO, INC. TEO HKQ AN❑ THE CONFIGURATION OF THIS PRODUCT ARE TRADEMARKS OF TECHKO INC. COPYRIGHT 1994 TECH KO, INC. 41 ALL RIGHTS RESERVED MADE IN CHINA Safe Pool TM Model S187D Area Entry Alarm O PERATION MANUAL INTRODUCTION Congratulations on your purchase of the TECH KO Safe Pool model S187D safety alarm. The Safe Pool can be used to provide a high volume alarm alert when children have entered a pool or spa area. The S187D can be used outdoors on wood or metal gates, or indoors on doors and window Leading directly to potentially dangerous areas. OPERATION �._.. — — __ _.......................... The Safe Pool is designed to sound a loud alert when children enter through a Safe Pool protected doorlgate. When property installed, the Safe Pool will allow adults to pass through the protected doorlgate and immediately shut off the sounding alarm. When powered, the Safe Pool is always in protection mode. The alarm will activate the instant when the door/gate opens 4more than 112 inch (when the magnetic sensors are apart more than 112 inch). Once the alarm activates, it will sound continuously until the BYPASS button is prossed. When passing through the door/gate press the BYPASS button, then open the doorlgate, pass through and close the doodgale within 8-12 seconds and the alarm will not activate. Easy installation for gate, door or window protection Water 1 weather resistant " 9 Volt battery power (not included) High output 110.115 dS alarm siren ' Low Battery I signal LED Indicator Optional additional BYPASS button for delayed entry from other side of door or fence Optional additional magnetic sensor for screen door exitlentry PARTS LIST S107e U T YPASS FIB. 1 I���i� lY \iEX60X O Q am.,ows a,uvnr.,wis„u, �e,E,oeo � �*, IMPORTANT_ SAFETY TIPS • Alarm siren is VERY loud; NEVER place the unit close to ears. ' Install the unit high enough to be out of reach of children 54` or higher is recommended. ' Keep this manual for future reference. The Safe Pool can provide valuable protection when used correctly. However, it cannot guarantee complete protection against accidents or injuries. Therefore, Techko cannot be held responsible for any loss, damage, or injury that may occur. INSTALLATION_ WARNING: Read all Installation and operation Instructions thoroughly before proceeding with installation. Note: Not all parts included are needed for installation. Please read the different mounting instructions to see what is needed for your specific application. INSTALLING THE BATTERY: 1. When testing, before installing the battery, use a rubber band to temporarily secure the two magnetic sensors together with the arrows pointing toward each other to avoid setting off the alarm unintentionally. During the actual installation of the alarm, it's best to install the battery after it's mounted to avoid the alarm going off unintentionally. 2. Remove the battery cover of the unit and install a new 9 Volt battery. Replace cover. (See Fig. 2) 3. If you are sensitive to loud sound, please wear oar protection against the loud alarm siren before testing the alarm. 4. Once the battery is connected, the unit is now ON and working. To test the alarm siren, make sure you have ear protection before testing. After ear protection is in place, separate the magnetic sensors Fly, 2 apart by more than Y2 inch. The alarm should sound immediately after the sensors are separated. Press the BYPASS button and immediately secure the two magnet sensors together again to avoid the alarm sounding off unintentionally. LED LIGHT WARNINGS 1. When the battery becomes low in charge or the volume becomes weak, the LED light will illuminate. The 9 volt battery must be replaced. 2. Upon battery installation, the unit will beep once and the LED light will flash 10 times as it prepares to become armed. 3. When a bypass button is pushed, the LED tight illuminates to indicate acknowledgement to PASS through. 4. After the bypass button is pushed in and released, the LED light will flash 10 times to allow pass through and to prepare the unit to become armed again. MOUNTING: WARNING: The alarm should be positioned close to the door high enough to be out of the reach of children. As each mounting application varies, Techko suggests testing the unit's installation location and effectiveness before permanently mounting the S1870. MOUNTING INDOORS Using the provided mounting template printed in this manual, mark the position of the screw holes on the desired mounting surface. * The Additional sa�, sl delay button may be mounted on the other side of the entrance. When pressed, it will `\ delay the alarm 8-12 seconds before alarm is triggered, allowing F_ time to secure the'.C_ _ door/gate. Fig. 3 * The Additional magnetic sensors allow the unit to be used on sliding door with screens. * Alarm will sound only when BOTH sets of magnetic sensors are apart, there for allowing the slider to be open while still providing protection at the screen door. MOUNTING INDOORS USING DOU9LE-SIDED TAPE Make sure that the mounting surfaces for the double -sided tapes are completely clean. Attach the double -sided tapes onto the rear of the unit, and then secure the unit onto the desired mounting surface. MOUNTING INDOORS USING SCREWS Using the provided mounting template printed in this manual, mark the position of the screw holes on the desired mounting surface. Drill the screws in to the mounting surface with approximately 1/8 inch of thread remaining. Slide the unit over the screws and secure the unit by a pushing it downward, as shown in Fig. 4. You may need to adjust the screws towards or away from the mounting surface to provide a more Fig, 4 secure fit. TEMPLATE MODEL S187D �j SCREW HOLE SCREW HOLE Jand ° Proedes INSTALLERS & AHJs* THE JANDY PRO -SERIES AND SAVill BRANDED NICHELESS LED UNDERWATER POOL AND SPA LUMINAIRES ARE LISTED LOW -VOLTAGE LUMINAIRES INTENDED TO BE POWERED BY NRTL-LISTED LOW -VOLTAGE POOU SPA TRANSFORMERS. WHEN INSTALLED PROPERLY AND IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE@ (NEC@)), THESE LUMINAIRES DO NOT REQUIRE ADDITIONAL PROVISIONS FOR BONDING AND/OR GROUNDING. THE JANDY PRO -SERIES AND SAVI BRANDED NICHELESS LIGHTS ARE CERTIFIED FOR "WET AREA" INSTALLATIONS, AND ARE COMPLETELY NONMETALLIC AND ARE INTENDED TO BE POWERED BY NRTL- LISTED LOW -VOLTAGE POOUSPA TRANSFORMERS, CERTIFIED AS COMPLIANT WITH THE APPLICABLE REQUIREMENTS OF THE STANDARD FOR SAFETY FOR "POWER UNITS FOR FOUNTAIN, SWIMMING POOL, AND SPA LUMINAIRES" (UL-379). WHEN INSTALLED PROPERLY IN ACCORDANCE WITH THEIR INSTALL I ION INSTRUCTIONS AND INACCORDANCEWITH THE NATIONAL ELECTRICAL CODE@ (NECO),THESE LUMIN IRES HAVE BEEN FOUND TO BE ACCEPTABLE FOR INSTALLATION IN AREAS WITHIN 10 FEET (3M) OF A POOL OR SPA. THEY ARE LISTED BY INTERTEK FOR SUCH INSTALLATIONS AND BEAR THE ETL LISTING MARK TO INDICATE THIS. ADDITIONALLY, THESE LIGHTS DO NOT REQUIRE ADDITIONAL PROVISIONS FOR BONDING AND/OR GROUNDING. - NEC PROVISIONS FOR UNBONDED LUMINAIRES: When these law -voltage luminaires are installed properly, the National Electrical Code (NEC) allows for an exception to the typical requirements for bonding and grounding in Articles 680.6 and 680.23. NEC PROVISIONS FOR POOL WATER BONDING: Article 680.26C of the NEC typically requires bonding of the pool Water. However per 680.26(B)(1) concrete pools are to be considered conductive due to the porous nature of concrete. If, on a concrete pool, the metal rebar of the pool base is properly bonded as required by the NEC, no aditional bonding is required. NEC PROVISIONS FOR MINIMUM DEPTH FOR INSTALLATION: Article 680.23(5) requires that pogl wall - mounted luminaires be installed such that the tap of the lens is a minimum of 18-inches below the normal water level of the pool, UNLESS the luminaire is listed and identified for use at lesser depths. Due to theirsealed 2-wire,12V, nonmetallic design, the Jandy Pro -Series and SAVI branded nicheless LED underwater pool and spa luminaires are suitable, and ETL listed, for installations at depths of only 4-inches below the normal water level of the pool. For assistance with product installation and usage, contact Zodiac Pool Systems, Inc. Technical Support 0�i�us at (800) 822-7933. c VuloMeshavingjuds(i bn Intertek MAW Is a register d trademark of hdiac htemational, SAS.U., used under license. R0492600 REV C cJan �Pro Series by ZODIAC- CS100 CS Cartridge Filter 100 Sq. Ft. CS150 CS Cartridge Filter 150 Sq. Ft. CS200 CS Cartridge Filter 200 Sq. Ft. CS250 CS Cartridge Filter 250 Sq. Ft. CS Filter Bead Loss Curves B 6 Design Head Loss (ft head) 4 2 0i 0 30 — C3150 CS200 CS250 CS100 60 90 F1Dw Rate (gpm) 3 Design Pressure 2 Drop (psi) 1 0 120 Technical Specifications W CS Series Filters 3,1'. Specifications and Dimensions, CS Series Filters Model No. CS100 CS150 CS200 CS250 Filter Area 100 fta 150 ft2 200 W 250 ft2 Design Flow Rate 1 gpm/ft2 .85 gpm/ft' .625 gpm/t17 .5 gpm/ft` Maximum Flow 100 gpm 125 gpm 125 gpm 125 gpm Six (6) Hour 36,000 45,000 gal- 45,000 45,000 gal - Capacity gallons Ions gallons Ions Eight (8) Hour 48,000 60,000 gal- 60,000 60,000 gal - Capacity gallons Ions gallons Ions Normal Start Up Pressure 6-15 psi 6-15 psi 6-15 psi 6-15 psi Max. Working 50 psi 50 psi 50 psi 50 psi Pressure Cartridges 1 1 t 1 Required Shipping Weight 28 lbs. 28 lbs. 341bs. 36 lbs. Height (`A') 323/a" 32'/a" 42'/2" 42'/2" www.ZodiacPooISystems.com 02011 Zodiac Pool Systems, Inc. SA6259 0611 ZODIAC' is a registered trademark of Zodiac International, S.A.S.U., used under license,