Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PRODUCT APPROVAL METAL ROOFING
1/15/2021 Florida Building Code Online Professional Regulation r BCIS Home I Log In I User Registration I Hot Topics I Submit Surcharge I Stats & Facts I Publications I Contact Us I E a Floridl r Product Approval �r � USER: Public User ar`�" Product Approval Menu > Product or Application Search > Application List > Application Detail FL # Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Referenced Standard and Year (of Standard) FL17022-R8 Revision 2020 Approved Extreme Metal Fabricators, LLC 2160 SW Poma Drive Palm City, FL 34990 (772) 872-8034 flvalidation@yahoo.com Richard McKuhen flvalidation@yahoo.com Richard McKuhen 2160 SW Poma Drive Palm City, FL 34990 (772) 872-8034 rchard@emfab.net Roofing Metal Roofing Evaluation Report from a Florida Registered Archie Professional Engineer Evaluation Report - Hardcopy Received David Eng PE-81377 Keystone Certifications, Inc. 04/22/2024 James R Wally, PE Validation Checklist - Hardcopy Received FL17022 R8 COI 26ga VMAX plywood.pdf Standard TAS 100 https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgv2aBQpHpQQe6rMZMkUEoR%2bd%2buNxXG%2bnlRhGTtoBWM1aQ%3d%3d 1/3 1/15/2021 Florida Building Code Online TAS 125 UL 580 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Method 1 Option D 10/05/2020 10/12/2020 10/25/2020 12/15/2020 12/16/2020 FL # Model, Number or Name Description 17022.1 01: 26ga VMax on Plywood 26ga (min) VMax 5V panel with 24" cc plywood or 3/4" (min) thick wood plar Limits of Use Installation Instructions Approved for use in HVHZ: No FL17022 R8 II 26ga VMAX plywooc Verified By: David Eng, PE 81377 Approved for use outside HVHZ: Yes Impact Resistant: N/A Created by Independent Third Party: Design Pressure: +N/A/-228 Evaluation Reports Other: Refer to evaluation report. FL17022 R8 AE 26ga VMAX plywoc Created by Independent Third Party: 7022.2 02: 032 Aluminum VMax on Plywood Nominally 0.032" aluminum (or thicke coverage on 15/32" (min) plywood or plank. Limits of Use Installation Instructions Approved for use in HVHZ: No FL17022 R8 II 032 VMAX 21in ply_, Verified By: David Eng, PE 81377 Approved for use outside HVHZ: Yes Impact Resistant: N/A Created by Independent Third Party: Design Pressure: +N/A/-168.5 Evaluation Reports Other: Refer to evaluation report. FL17022 R8 AE 032 VMAX 21in ply Created by Independent Third Party: 17022.3 03: 26ga VMax on Plywood 26ga (min) VMax 5V panel with 24" cc plywood or 3/4" (min) thick wood plar the flats and in the ribs. Limits of Use Installation Instructions Approved for use in HVHZ: No FL17022 R8 II 26ga VMAX plywooc Verified By: David Eng, PE 81377 Approved for use outside HVHZ: Yes Impact Resistant: N/A Created by Independent Third Party: Design Pressure: +N/A/-114.25 Evaluation Reports Other: Refer to evaluation report. FL17022 R8 AE 26ga VMAX plywoc Created by Independent Third Party: 17022.4 04: 26ga CorMax on Plywood 26ga (min) CorMax corrugated panel 15/32" (min) plywood or 3/4" (min) tl Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL17022 R8 II 26ga CorMax Plywo Verified By: David Eng, PE 81377 Approved for use outside HVHZ: Yes Impact Resistant: N/A Created by Independent Third Party: https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgv2aBQpHpQQe6rMZMkUEoR"/"2bd"/"2buNxXG°/`2bnlRhGTtoBWM1aQ%3d%3d 2/3 1/15/2021 Florida Building Code Online Design Pressure: +N/A/-161 Other: Refer to evaluation report. 17022.5 05: 26ga CorMax on Battens Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-161 Other: Refer to evaluation report. Evaluation Reports FL17022 R8 AE 26ga CorMax Plyw( Created by Independent Third Party: 26ga (min) CorMax corrugated panel (min) battens. Installation Instructions FL17022 R8 II 26ga CorMax Batter Verified By: David Eng, PE 81377 Created by Independent Third Party: Evaluation Reports FL17022 R8 AE 26ga CorMax BattE Created by Independent Third Party: Back Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility St Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a pub electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please cor Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the I if they have one. The emails provided may be used for official communication with the licensee. However email addresses are to supply a personal address, please provide the Department with an email address which can be made available to the pL licensee under Chapter 455, F.S., please click here . Product Approval Accepts: © U ® EC t M Credit Card Safe https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgv2aBQpHpQQe6rMZMkUEoR%2bd%2buNxXG%2bnlRhGTtoBWM1aQ%3d%3d 3/3 MAX FL17022.01-R8 W I Er�.WA,& d-METAL FABRICATORS SKILLED CRAFTERS '7F METAL ROOFING SYSTEMS 26ga (min) MAX over 15/32" (min) plywood Extreme Metal Fabricators 2120 SW Poma Dr I Palm City FL 34990 Product Description 5V Crimp style exposed fastener panel with 24" max coverage and nominal rib height of 3/8". Product Material 26ga (min) steel Corrosion resistant per FBC 1507.4.3 where required Fastener #9 or #10 x 1.5" fastener with sealing washer Compliant with FBC 1506.6 where required. Substrate/Deck 15/32" (min) plywood or 3/4" (min) thick wood plank (min S.G. of 0.42) Evaluated by: David Eng, PE Timberlake Cove, LLC 3324 W Univ Ave #206 1 Gainesville FL FL PE 81377 1 FL CA 33344 www.Ti m be rLa keCove.com MAX FL17022.01-R8 Underlayment: Comply with local building code or FBC 1507.1.1 where required. Slope: Comply with local building code or FBC 1507.4.2 where required. Re -Roofing: This panel may be installed over a single layer of existing shingles as permitted by local building code or FBC 1511, provided the existing roof meets the conditions required by the applicable code. Maximum Allowable Loads & Installation Requirements: Method A: #9 x 1.5" fastener in 12"-12" pattern at 16" o.c.: 86 PSF Method B: #10 x 1.5" fastener in 12"-12" pattern at 16" o.c.: 93.5 PSF Method C: #10 x 1.5" fastener in 12"-12" pattern at 8" o.c.: 101 PSF Method D: #10 x 1.5" fastener in 12"-12" pattern at 6" o.c.: 228 PSF A factor of safety of 2 has been applied. Technical Documentation: This product has been tested to the UL 580 standard by Architectural Testing (now Intertek Testing, TST-1527), report D05893.01-450-18, F3366.01-450-18, and D05893.02-450-18. As referenced in FL 17022.01-R7 Compliance Statement: This product as described has demonstrated compliance with Florida Building Code 2020, 1504.3.2 (non-HVHZ) as required by FL Rule 61G20-3, method 1D. This product as described has been tested and demonstrated compliance with: • UL580 - Test for Uplift Resistance of Roof Assemblies • UL 1897 - Uplift test for roof covering systems Design Process: The load tables in this report provides one prescriptive option for the fastening requirement for the applicable wind loads for roofs within the parameters described. For roofs outside of the listed parameters, design wind loads shall be determined as required by FBC 1609, ASCE 7, or other design code in force, using allowable stress. These load tables are based on ASCE 7-16. Use of these tables assumes that the structure is: • Enclosed and conforms to wind-borne debris provisions and is a regular shaped building • Is not subject to across -wind loading, vortex shedding, or instability; nor does it have a site location for which channeling or buffeting warrant consideration Engineering analysis may be completed by other licensed engineers for project specific approval by local authorities having jurisdiction. Certification of Independence: David Eng, PE and Timberlake Cove, LLC do not have, nor will acquire a financial interest in any company manufacturing or distributing products under this evaluation. The same entities do not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. Exclusions and Limitations: Design of deck and roof structure (to include attachment of plywood or wood plank) shall be completed by others. Fire classification and shear diaphragm design are outside the scope of this evaluation. Accelerated weathering/salt spray is outside the scope of this evaluation. This report is limited to compliance with structural wind load requirements of FBC 1504.3.2, as required by Rule 61G20-3. Neither Timberlake Cove nor the manufacturer shall be responsible for any conclusions, interpretations, or designs made by others based on this evaluation report. This report is limited solely to documenting compliance with Rule 61G20-3, and makes no express or implied warranty regarding performance of this product. Installation shall be subject to the local building code and authority having jurisdiction; this report shall not be construed to supersede local codes in force. MAX L_FL17022.01-R8 Instructions: Select the appropriate load table that applies to the structure in question. Determine the design wind speed for the project location. Use the attachment method indicated for that windspeed within each roof zone. NOTE: ASCE 7-16 and FBC 2020 adopt a 7-zone concept. For the load tables below, the worst case was taken for each zone and reported using the standard zones 1-2-3: Zone 1 includes zones 1 and 1' Zone 2 includes zones 2e, 2r, and 2n Zone 3 includes zones 3e and 3r i a Combining these zones creates a clear, simple LESS THAN E17HER 441ZONTAL DIMENSION OR 0.4h,% OF LEAST HORIZONTAL DIMENSION OR 3Fr;Gsnii R, evr NOT scheme, at the expense of some design efficiency. OR AS DETERMINED BY DESIGN OR OTHER APPLICABLE CODE. Contact the manufacturer for further information, ROOF ZONES FOR GENERIC BUILDING or consult a licensed design professional. METHOD A: METHOD B: METHOD C: METHOD D: #9 AT 16" O.C. #10 AT 16" O C_ #10 AT 8" O.C. #10 AT 6" O C �12" (NOM) 12" (NOM)� NR Use this load table for structures which meet the following criteria: Are located in Exposure B area Have either a flat roof, or gable/hip roof with max slope of 12:12 Have a mean Roof Height of 30 feet or less NOT RATED. CONSULT DESIGN PROFESSIONAL AS NEEDED Use this load table for structures which meet the following criteria: Are located in B, C, or D exposure area Have either a flat roof, or gable/hip roof with max slope of 12:12 Have a mean Roof Height of 30 feet or less FL17022.01: 26 a 5V Crimp on 15/32" Plywood FL17022.01: 26 a 5V Crimp on 15/32" Plywood Wind 105 110 120 130 140 150 160 170 180 190 200 Wind 105 110 120 130 140 150 160 170 180 190 200 Zone 1: A A A A A A A A A A A Zone 1: A A A A A A A C Zone 2: A A A A A A A A C D D Zone 2: A A A A C D D D D D D Zone 3: A A A A A A B C D D D Zone 3: A A A C D D D D D D Use this load table for structures which meet the following criteria: Use this load table for structures which meet the following criteria: Are located in Exposure B area Are located in B, C, or D exposure area Have either a flat roof less than 7D, hip roof with Have either a flat roof less than 7°, hip roof with max slope of 12:12, or gable roof with slope between 4.4:12 & 12:12 max slope of 12:12, or gable roof with slope between 4.4:12 & 12:12 Have a mean Roof Height of 30 feet or less Have a mean Roof Height of 30 feet or less FL17022.01: 26 a 5V Crimp on 15/32" Plywood FL17022.01: 26 a 5V Crimp on 15/32" Plywood Wind 105 110 120 130 140 150 160 170 180 190 200 Wind 105 110 120 130 140 150 160 170 180 190 200 Zone 1: A A A A A A A A A A A Zone 1: A A A A A A A B C' Zone 2: A A A A A A A A A B C Zone 2: A A A A A B D D D D D Zone 3: A A A A A A A B D D 10 Zone 3: A A A B N D D D D D D