Loading...
HomeMy WebLinkAboutEnergy Efficiency CodeFORM 405-10 -FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: GREEN RESIDENCE Builder Name: Street: 105 ��n L3� Permit office: City, State, Zip: ST. LUCIE COUNTY, FL Owner: Permit Number: Jurisdiction: Design Location: FL, Fort Pierce 1. New construction or existing New (From Plans) 9. Wall Types (1696.0 sqft.) Insulation Area a. Frame - Wood, Exterior R=19.0 1696.00 ft2 2. Single family or multiple family Single-family b. N/A R= f Z 3. Number of units, if multiple family 1 c. NIA R= ft2 4. Number of Bedrooms 3 d. NIA 10. Ceiling Types (2321.0 sqft.) R= ft2 insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=30.0 2321.00 ft' 6. Conditioned floor area above grade (ft) 2321 b. N/A R= ft2 ft2 c. N/A R= Conditioned floor area below grade (ft) 0 11. Ducts R ft2 7. Windows(305.0 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Main 6 185 a. U-Factor: Sgi, U=0.55 245.00 ft2 SHGC: SHGC=0.30 12. Cooling systems kBtuRir Efficiency b. U-Factor: Sgl, U=1.30 60.00 ft2 a. Central Unit 47.0 SEER:13.00 SHGC: SHGC=0.64 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtulhr Efficiency d. U-Factor: NIA ft2 a. Electric Heat Pump 34.0 HSPF:7.70 SHGC: Area Weighted Average Overhang Depth: 6.879 ft. Area Weighted Average SHGC: 0.367 14. Hot water systems a. Electric Tankless Cap: 1 gallons 8. Floor Types (2321.0 sqft.) Insulation Area EF: 0.717 a. Slab -On -Grade Edge Insulation R=0.0 2321.00 f' b. Conservation features b. N/A R= ft2 None c. N/A R= f Z 15. Credits 4 CF, Pstat Total Proposed Modified Loads: 34.71 PASS Glass/Floor Area: 0.131 Total Standard Reference Loads: 46.00 1 hereby certify that the plans and specifications covered by Review of the plans and O�FiE S);q this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance ����,,''' , ,.�',,��A A• with the Florida Energy Code. Po,,,��.''•. PREPARED BY:4 Before construction is completed DATE: this building will be inspected for compliance with Section 553.908 t. • I hereby certify that this building, as'designed, is in compliance Florida Statutes. CO 'C���� 01NE with the Florida Energy de. OWNER/A EN BUILDING OFFICIAL: DATE: DATE: TO"" C4t4001ECEIVED OCT 1' 2 2012 PERMITTING St. Lucie County, FL 10/812012 8:21 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 5 PROJECT Title: Building Type: Owner: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: GREEN RESIDENCE User 1 Single-family New (From Plans) Bedrooms: 3 Conditioned Area: 2321 Total Stories: 1 Worst Case: No Rotate Angle: 0 Cross Ventilation: Whole House Fan: Address Type: Street Address Lot # Block/SubDivision: PlatBook: Street: County: ST. LUCIE COUNTY City, State, Zip: ST. LUCIE COUNTY, FL, CLIMATE / v Design Location IECC Design Temp TMY Site Zone 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, Fort Pierce FL ST LUCIE_CO_INTL 2 39 90 70 75 722 62 Low BLOCKS Number Name Area Volume 1 Blockl 2321 18568 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 2321 18568 Yes 4 3 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Stab -On -Grade Edge Insulatio Main 156 ft 0 2321 ftz 0 0 1 ROOF / V # Type Roof Gable Roof Materials Area Area Color Solar Absor. SA Emitt Emitt Deck Pitch Tested Tested Insul. (deg) 1 Hip Composition shingles 2514 ftz 0 ftz Medium 0.96 No 0.9 No 0 22.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 2321 ftz N N CEILING # Ceiling Type Space R-Value Area Framing Frac Truss Type 1 Under Attic (Vented) Main 30 2321 ftz 0.11 Wood 10/8/2012 8:21 AM EnergyGaugeO USA - FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 5 WALLS / V Adjacent Wall Type Space Cavity Width Height Sheathing Framing Solar RAla lue Ft In Et In Area R Valup Below # C)mt 1 N 2 E _ 3 S 4 W To Exterior Frame - Wood Exterior Frame - Wood Exterior Frame - Wood Exterior Frame - Wood Main Main Main Main 19 78 8 19 28 8 19 78 8 19 28 8 624 ftz 0 224 ftz 0 624 ftz 0 224 ft' 0 0 0.75 0 0.75 0 0.75 0 0.75 0 0 0 0 DOORS # Ornt Door Type Space Storms U-Value Width Ft In Height Ft In Area 1 2 N N Insulated Insulated Main Main None None 0.460000 3 0.4 3 6 8 6 8 20 ft' 20 ftz WINDOWS Orientation shown is the entered, Proposed orientation. / V # Wall Omt ID Frame Panes NFRC U-Factor SHGC Overhang Area Depth Separation Int Shade Screening 1 2 3 4 5 6 N 1 Vinyl N 1 Vinyl N 1 Vinyl E 2 Vinyl S 3 Vinyl W 4 Vinyl Single (Tinted) Single (Tinted) Single (Tinted) Single (Tinted) Single (Tinted) Single (Tinted) Yes Yes Yes Yes Yes Yes 0.55 0.3 0.55 0.3 0.55 0.3 0.55 0.3 0.55 0.3 1.3 0.64 80 ftz 2 ft 0 in 7 ft 0 in 27 ftz 2 ft 0 in 7 ft 0 in 6 ftz 10 ft 0 in 8 ft 0 in 12 ftz 2 ft 0 in 6 ft 0 in 120 ftz 10 ft 0 In 6 it 0 in 60 ftz 10 ft 0 in 6 it 0 in Drapes/blinds Drapes/blinds Drapes/blinds Drapes/blinds Drapes/blinds Drapes/blinds None None None None None None INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Best Guess 0.000500 3044.01 167.112 314,278 0.36500 9.83630 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump None HSPF: 7.7 34 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts f Central Unit None SEER: 13 47 kBtu/hr 1410 cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric Tankless Main 0.66 1 gal 60 gal 120 deg None 1018/2012 8:21 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 5 SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS / — Supply — — Return — Air Percent HVAC # V # Location R-Value Area Location Area Leakage Type Handler CFM 25 Leakage ON RLF Heat Cool 1 Attic 6 185 ft2 Attic 25 ft2 Default Leakage Main (Default) (Default) % 1 1 TEMPERATURES Programabie Thermostat: Y Ceiling Fans: Cooling Jan Heating Jan [ ] Feb [X] Feb Mar Mar Apr Pr May X Jun X Jul May Jun Jul AuSep rj Au Se WOct Oct Nov Nov Dec Dec H Venting Jan [) Feb X Mar A r [ l Ma [ Jun [ ]]] Jul l L Aug Se Oct X Nov X Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM PM 78 80 78 80 78 78 78 78 78 78 78 78 78 78 78 78 80 78 80 78 80 78 80 78 Cooling (WEH) AM PM 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 Heating(VVD) AM PM 66 68 66 68 66 68 66 66 68 68 68 68 68 68 68 68 68 68 68 68 68 66 68 66 Heating (WEH) AM PM 66 68 66 68 66 68 66 66 68 68 68 68 68 68 68 68 68 68 68 68 68 66 68 66 10/8/2012 8:21 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 5 FORM 405-10 Florida Code Compliance Checklist Florida Department of Business and Professional Regulations Residential Whole Building Performance Method ADDRESS: PERMIT #: ST. LUCIE COUNTY, FL, MANDATORY REQUIREMENTS SUMMARY - See individual code sections for full details. COMPONENT SECTION SUMMARY OF REQUIREMENT(S) CHECK Air leakage 402.4 To be caulked, gasketed, weatherstripped, or otherwise sealed. Recessed lighting IC -rated as meeting ASTM E 283. Windows and doors = 0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces: gasketed doors & outdoor combustion air. Must complete envelope leakage report or visually verify Table 402.4.2. Thermostat & 403.1 At least one thermostat shall be provided for each separate heating controls and cooling system. Where forced -air furnace is primary system, programmable thermostat is required. Heat pumps with supplemental electric heat must prevent supplemental heat when compressor can meet the load. Ducts 403.2.2 All ducts, air handlers, filter boxes and building cavities which form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section 503.2.7.2 of this code. 403.3.3 Building framing cavities shall not be used as supply ducts. Water heaters 403.4 Heat trap required for vertical pipe risers. Comply with efficiencies in Table 403.4.3.2. Provide switch or clearly marked circuit breaker (electric) or shutoff (gas). Circulating system pipes insulated to = R-2 + accessible manual OFF switch. Mechanical 403.5 Homes designed to operate at positive pressure or with mechanical ventilation ventilation systems shall not exceed the minimum ASHRAE 62 level. No make-up air from attics, crawlspaces, garages or outdoors adjacent to pools or spas. Swimming Pools' 403.9 Pool pumps and pool pump motors with a total horsepower (HP) of = 1 & Spas HP shall have the capability of operating at two or more speeds. Spas and heated pools must have vapor -retardant covers or a liquid cover or other means proven to reduce heat loss except if 70% of heat from site -recovered energy. Off/timer switch required. Gas heaters minimum thermal efficiency=78% (82% after 4/16/13). Heat pump pool heaters minimum COP= 4.0. Cooling/heating 403.6 Sizing calculation performed & attached. Minimum efficiencies per Tables 503.2.3. Equipment efficiency verification required. Special equipment occasion cooling or heating capacity requires separate system or variable capacity system. Electric heat >10kW must be divided into two or more stages. Ceilings/knee walls 405.2.1 R-19 space permitting. 10/8/2012 8:21 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 5