Home
My WebLink
About
Project Information
Project Summary +- wrightsoft° Date: Entire House By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL34M Phone: 772-466.6799 Fax 772-466-6796 Emall: QUICXCALCS@PAL.COM Proiect Information For. GREEN RESIDENCE ST. LUCIE COUNTY,F L Notes: Weather. Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range Relative humidity L 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 23297 Btuh Structure 34393 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent (85 cfm) 2603 Btuh Central vent (85 cfm) 1394 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 25900 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 33998 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 3715 Btuh Ducts 0 Btuh Heating Cooling Central vent (85 cfm) 3533 Btuh Area (ft') 2321 2321 Equipment latent load 7248 Btuh Volume (ft') 20781 20781 Air changes/hour 0.32 0.16 Equipment total load 41246 Btuh Equiv. AVF (cfm) 111 55 Req. total capacity at 0.70 SHR 4.0 ton Heating Equipment Summary Cooling Equipment Summary Make Make Trane Trade Trade XR13 Model Cond 2TTR3048A1000AA AHRI ref no. n/a Coil AHOSA4ANF048 AHRI ref no. Efficiency 100 EFF Efficiency 11.0 EER, 13 SEER Heating input 0 Btuh Sensible cooling 32900 Btuh Heating output 25900 Btuh Latent cooling 14100 Btuh Temperature rise 20 OF Total cooling 47000 Btuh Actual air flow 1200 cfm Actual air flow 1200 cfm Air flow factor 0.052 cfm/Btuh Air flow factor 0.035 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.83 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wri htsoft zolz-oa-os os:age I 9 RightSuiteC9 Universal 2012 12.0:07 RSU08101 page 1 ACCA ...sers\Quick Calcs\Documents\Wrightsoft WAC\GREEN RESIDENCE.rup Cale = MJ8 Front Door faces: -+ wrightsoft° Right-JO Worksheet Job: Entire House Date: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUIC(CALCS@PAL.COM 1 Room name Entire House KITCHEN 2 Exposed wall 221.9 ft 14.0 ft 3 Room height 9.0 ft d 9.0 ft heat/cool 4 Room dimensions 14.0 x 10.0 ft 5 Room area 2309.0 ft' 140.0 fL2 Ty Construction U-value Or HTM Area (fY) Load Area (" Load number (Btuh/ft;"F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 13A5ocs 0.125 n 3.50 2.22 315 255 893 567 0 0 0 0 �-G 1Ac1om 1.270 n 35.56 34.77 60 0 2134 2086 0 0 0 0 VN 13A5ocs 0.125 a 3.50 2.22 684 579 2026 1288 126 108 378 240 10A-v 0.820 a 22-96 38.88 40 0 924 1564 0 0 0 0 11 10A-v 0.820 a 22.96 38.88 41 0 937 1586 0 0 0 0 1A-clom 1.270 a 35.56 91.12 24 0 853 2187 18 0 640 1640 W I--G 13A5ocs 0.125 s 3.50 2.22 315 309 1082 688 0 0 0 0 1Ac1om 1.270 s 35.56 34.77 6 6 213 2D9 0 0 0 0 13A50cs 0.125 w 3.50 2.22 684 524 1835 1166 0 0 0 0 10A-v 0.820 w 22.96 38.88 40 0 924 1564 0 0 0 0 1Aclom 1.270 w 35.56 91.12 120 0 4252 10896 0 0 0 0 C 16B30a1 0.032 - 0.90 1.68 2309 2309 2069 3879 140 140 125 235 F 21A-20c 0.027 - 0.76 0.00 2309 2309 1746 0 140 140 106 0 6 c) AE D e)cursion 2188 -163 Envelope loss/gain 19887 29869 1249 1953 12 a) Infiltration 3411 914 215 58 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 7 1610 0 0 Appliances/other 2000 2000 Subtotal (lines 6 to 13) 23297 34393 1464 4010 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redstribution 0 0 0 0 14 Subtotal 23297 34393 1464 4010 15 Duct loads 0% 00/0 0 0 -00/0 0% 0 0 Total mom load 23297 34393 1464 4010 Air required (cfm) 1200 1200 75 140 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -11 2012-Oct-08 09:10:04 44- W rightsoft' RightSuke® Universal 2012 12.0.07 RSU08101 Page 1 .4CCA ...sers\Quick Calcs\Documents\Wrightsoft WAC\GREEN RESIDENCE.rup Calc = MJ8 Front Door faces: wrightsoft, Right-J® Worksheet Job: Entire House Date: By: QUICK CALCS, INC. 317 ST. LUGE LN., FT. PIERCE, FL34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKC4LCS@AOL.COM 1 Room name DINING ROOM OFFICE 2 Exposed wall 20.0 ft 26.0 ft 3 Room height 9.0 ft heat/cool 9.0 ft heaUcool 4 Room dimensions 1.0 x 349.5 ft 1.0 x 230.0 ft 5 Room area 349.5 ftz 230.0 ft2 Ty Construction U-value Or HTM Area (ftz) Load Area (ftz) Load number (Btuh/ftz--°F) (Btuh/ftz) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 13A-5ocs 0.125 n 3.50 2.22 0 0 0 0 45 45 158 100 L-G 1A-clom 1.270 n 35.56 34.77 0 0 0 0 0 0 0 0 VL� 13A-5ocs 0.125 a 3.50 2.22 180 139 487 310 0 0 0 0 10A-v 0.820 a 22.96 38.88 0 0 0 0 0 0 0 0 11 10A-v 0.820 a 22.96 38.88 41 0 937 1586 0 0 0 0 1A-c1om 1.270 a 35.56 91.12 0 0 0 0 0 0 0 0 W 13A-5ocs 0.125 s 3.50 2.22 0 0 0 0 54 54 189 120 L-G 1A-clom 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0 13A-5ocs 0.125 w 3.50 2.22 0 0 0 0 135 95 334 212 10A-v 0.820 w 22.96 38.88 0 0 0 0 0 0 0 0 lAclom 1.270 w 35.56 91.12 0 0 0 0 40 0 1408 3607 C 16B-30ad 0.032 - 0.90 1.68 350 350 313 587 230 230 206 386 F 21A-20c 0.027 - 0.76 0.00 350 350 264 0 230 230 174 0 6 c) AE D excursion -105 1132 Envelope loss/gain 2001 2378 2468 5558 12 a) Infiltration 307 82 399 107 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 3 690 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 2309 3151 2867 5665 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 51 68 0 0 14 Subtotal 2359 3219 2867 5665 15 Duct loads -0% 0% 0 0 -0% 0% 0 0 Total room load 2359 3219 2867 5665 Air required (cfm) 122 112 148 198 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. .1. Wrl htsofC` 2012-Oct-0809:10:04 . 1 . 9 Right -Suite® Universal 2012 12.0.07 RSU08101 Page 2 ...sers\Quick Calcs\Documents\Wrightsoft HVAC\GREEN RESIDENCE.rup Cale = MJ8 Front Door faces: wrightsoft` Right-J® Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LN., FT. PIERCE, FL34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name LIVING ROOM BEDROOM 3 2 Exposed wall 13.0 ft 11.9 ft 3 Room height 9.0 ft heat/cool 9.0 ft heat/ocol 4 5 Room dmensions Room area 1.0 x 264.5 ft 264.5 ftz 1.0 x 135.5 ft 135.5 ftz Ty Construction U-value Or HTM Area (ftz) Load Area (ftz) Load number (Btuh/ftz-°F) (Btuh/ftz) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/PIS Heat Cool 6 W 13A-5ocs 0.125 n 3.50 2.22 0 0 0 0 0 0 0 0 1Ac1om 1.270 n 35.56 34.77 0 0 0 0 0 0 0 0 VN 13A5ocs 0.125 a 3.50 2.22 0 0 0 0 0 0 0 0 10A-v 0.820 a 22.96 38.8E 0 0 0 0 0 0 0 0 11 10A-v 0.820 a 22.96 38.88 0 0 0 0 0 0 0 0 1Aclom 1.270 a 35.56 91.12 0 0 0 0 0 0 0 0 W 13A5ocs 0.125 s 3.50 2.22 0 0 0 0 0 0 0 0 L-G 1A-clam 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0 1Tl 13A5ocs 0.125 w 3.50 2.22 117 77 269 171 108 88 308 196 10A-v 0.820 w 22.96 38.88 40 0 924 1564 0 0 0 0 'I-G CI IA-clom 1.270 w 35.56 91.12 0 0 0 0 20 0 711 1822 C 16830ad 0.032 - 0.90 1.68 265 265 237 444 136 136 121 228 F 21A-20c 0.027 - 0.76 0.00 265 265 200 0 136 136 102 0 6 c) AED excursion 380 572 Envelope loss/gain 1629 2559 1243 2817 12 a) Infiltration 200 53 184 49 b) Room ventilation 0 01 0 0 13 Intemal gains: Occupants @ 230 4 920 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 1829 3533 1427 2867 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 71 95 14 Subtotal 1829 3533 1498 2962 15 Duct loads -0% 00/0 0 0 -0% 0% 0 0 Total room load 1829 3533 1498 2962 Air required (cfm) 94 123 77 103 Calculations awroved bvACCAto meet all reouirements of Manual J 8th Ed. wri htsOFC 2012-Oct-08 09:10:04 9 RightSuite® Universal 2012 12.0.07 RSU08101 Page 3 ACCA „.sers\Quick Calcs\Documents\Wdghtsoft HVAC\GREEN RES I DENCE. rup Calc = MJ8 Front Door faces: + wrightsoft° Right-J® Worksheet Job: Entire House Date: By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@POL.COM 1 Room name BEDROOM 2 MASTER BEDROOM 2 Exposed wall 12.0 ft 30.0 ft 3 Room height 9.0 ft heat/cool 9.0 ft heat/cool 4 Room dimensions 1.0 x 172.0 ft 1.0 x 201.0 ft 5 Room area 1720 ft2 201.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/W-°F) (Btuh/fe) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat cool 6 WL_G 13A5ocs 0.125 n 3.50 2-22 0 0 0 0 0 0 0 0 1A-c1om 1.270 n 35.56 34.77 0 0 0 0 0 0 0 0 13A5ocs 0.125 a 3.50 2.22 0 0 0 0 0 0 0 0 10A-v 0.820 a 22.96 38.88 0 0 0 0 0 0 0 0 11 10A-v 0.820 e 2296 38.88 0 0 0 0 0 0 0 0 IA-c1om 1.270 a 35.56 91.12 0 0 0 0 0 0 0 0 W 13A5ocs 0.125 s 3.50 222 0 0 0 0 162 156 546 347 L--G 1A-clom 1.270 s 35.56 34.77 0 0 0 0 6 6 213 209 13A5ocs 0.125 w 3.50 2.22 108 88 308 196 108 88 308 196 10A-v 0.820 w 2296 38.88 0 0 0 0 0 0 0 0 1Aclom 1.270 w 35.56 91.12 20 0 711 1822 20 0 711 1822 C 16B30ad 0.032 - 0.90 1.68 172 172 154 289 201 201 180 338 F 21A-20c 0.027 - 0.76 0.00 172 172 130 0 201 201 152 0 6 c)AEDecursion 567 442 Envelope loss/gain 1303 2874 2111 3354 12 a) Infiltration b) Room ventilation 184 0 49 0 461 0 123 0 13 Intemal gains: Occupants @ 230 0 0 0 0 1 Appliances/other 0 0 Subtotal (lines 6 to 13) 1488 2923 2571 3477 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 142 191 81 109 14 Subtotal 1629 3114 2652 3586 15 Duct loads -0% 0% 0 0 -0% 00/0 0 0 Total room load 1629 3114 2652 3586 Air required (cfm) 84 109 137 125 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. .1. Wrl htSOft- J 2012-Oct-0809:10:04 Yr g RightSuite® Universal 2012 12.0.07 RSU08101 Page 4 ALGA ...sere\Quick Calcs\Documents\Wrightsoft HVAC\GREEN RESIDENCE. rup Calc = MJ8 Front Door faces: wrightsoft` Right-JO Worksheet Job: Entire House Date: By: QUICK CALCS, INC. 317 ST. LUGE LN., FT. PIERCE, FL34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUIo(CALCS@PDL.COM 1 Room name UTILITY BATH 3 2 Exposed wall 20.0 ft 10.0 ft 3 Room height 9.0 ft heat/000l 9.0 ft heat/cool 4 Room dimensions 9.0 x 11.0 ft 1.0 x 120.0 ft 5 Room area 99.0 W 120.0 ft' Ty Construction U-value Or HTM Area (ft') Load Area (ft') Load number (Btuh/ftz °F) (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 13A-0ocs 0.125 n 3.50 2.22 0 0 0 0 0 0 0 0 L--G 1A�lom 1.270 n 35.56 34.77 0 0 0 0 0 0 0 0 13A-5ocs 0.125 a 3.50 2.22 81 81 284 180 90 84 294 187 10A-v 0.820 a 22.96 38.88 0 0 0 0 0 0 0 0 11 10A-v 0.820 a 22.96 38.88 0 0 0 0 0 0 0 0 IA-clom 1.270 a 35.56 91.12 0 0 0 0 6 0 213 547 W 13A-5ocs 0.125 s 3.50 2.22 99 99 347 220 0 0 0 0 L--G 1A-clom 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0 1/tJ 13A-5ocs 0.125 w 3.50 2.22 0 0 0 0 0 0 0 0 10A-v 0.820 w 22.96 38.88 0 0 0 0 0 0 0 0 1A-clom 1.270 w 35.56 91.12 0 0 0 0 0 0 0 0 C -16B-30ad 0.032 - 0.90 1.68 99 99 89 166 120 120 108 202 F 21A-20c 0.027 - 0.76 0.00 99 99 75 0 120 120 91 0 6 c) AED e)cursion -54 -20 Envelope loss/gain 794 513 7061 915 12 a) Infiltration 307 82 154 41 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 1101 595 859 956 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution ill 150 121 163 14 Subtotal 1212 745 981 1120 15 Duct loads -0% 0% 0 0 -0% 0% 0 0 Total room load 1212 745 981 1120 Air required (cfm) 62 26 51 39 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. 2012-0d-08 09:10:04 C. -wri 1tsOTY RightSuite® Universal 2012 12.0.07 RSU08101 Page 5 ACA .„sers\Quick Calcs\Documents\Wdghtsoft WAC\GREEN RESIDENCE.rup Calo = MJ8 Front Door faces: +�- wrightsoft° Right-M Worksheet Job: Entire House Date: By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name MST BATH HALL 2 Exposed wall 9.0 ft 3.0 ft 3 Room height 9.0 ft heat/cool 9.0 ft heat/cool 4 Room dimensions 9.0 x 11.0 ft 1.0 x 153.0 ft 5 Room area 99.0 ft2 153.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 13A5ocs 0.125 n 3.50 2-22 0 0 0 0 0 0 0 0 L--G 1A-c1om 1.270 n 35.56 34.77 0 0 0 0 0 0 0 0 13A-5ocs 0.125 a 3.50 2.22 81 81 284 180 27 7 25 16 10A-v 0.820 a 2296 38.88 0 0 0 0 20 0 455 771 11 10A-v 0.820 a 22.96 38.88 0 0 0 0 0 0 0 0 1A-c1om 1.270 a 35.56 91.12 0 0 0 0 0 0 0 0 W 13A5ocs 0.125 s 3.50 2.22 0 0 0 0 0 0 0 0 L-G 1A-clom 1.270 a 35.56 34.77 0 0 0 0 0 0 0 0 1�J 13A5ocs 0.125 w 3.50 222 0 0 0 0 0 0 0 0 FL---GG 10A-v 0.820 w 22.96 38.88 0 0 0 0 0 0 0 0 1Aclom 1.270 w 35.56 91.12 0 0 0 0 0 0 0 0 C 16B30ad 0.032 - 0.90 1.68 99 99 89 166 153 153 137 257 F 21A-2Dc 0.027 - 0.76 0.00 99 99 75 0 153 153 116 0 6 c) AED e)cursion -32 -8 Envelope loss/gain 1 447 315 733 1037 12 a) Infiltration 138 37 46 12 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 10 Subtotal (lines 6 to 13) 585 352 779 1049 Less external load 0 0 0 0 Less transfer 0 . 0 0 0 Redistribution 202 272 779 -1049 14 Subtotal 788 624 0 0 15 Duct loads -00/0 0% 0 0 -0% 0% 0 0 Total room load 788 624 0 0 Air required (cfm) 41 22 0 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrightsoft' RightSuite® Universal 2012 12.0.07 RSU08101 P 2012 Oct-08 0 age 6 ACCA Page 6 ...secs\Quick Calcs\Documents\Wrightsoft HVACIGREEN RESIpENCE.cup Calc = MJS Front Door faces: +- wrightsoft° Right-J® Worksheet Job: Entire House Date: By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@PAL.COM 1 Room name FLORIDAROOM 2 Exposed wall 53.0 ft 3 Room height 9.0 ft heat/cool 4 Room dimensions 1.0 x 345.5 ft 5 Room area 345.5 ft2 Ty Construction U-value Or HTM Area (ft) Load Area Load number (Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 13ASocs 0.125 n 3.50 2.22 270 210 735 467 �---G 1A clam 1.270 n 35.56 34.77 60 0 2134 2086 13A-5ocs 0.125 a 3.50 2.22 99 79 275 175 10A v 0.820 a 22.96 38.88 20 0 468 793 11 10A-v 0.820 a 22.96 38.88 0 0 0 0 IA-c1om 1.270 a 35.56 91.12 0 0 0 0 W L---G 13A-0ocs 0.125 s 3.50 2.22 0 0 0 0 1A-c1om 1.270 s 35.56 34.77 0 0 0 0 VIJ 13A-5ocs 0.125 w 3.50 2.22 108 88 30B 196 {L--GG 10A-v 0.820 w 22.96 38.88 0 0 0 0 IA-clom 1.270 w 35.56 91.12 20 0 711 1822 C 16B-30ad 0.032 - 0.90 1.68 346 346 310 580 F 21A-20c 0.027 - 0.76 0.00 346 346 261 0 6 c)AEDex;ursion -524 Envelope loss/gain 5202 5597 12 a) Infiltration 814 218 b) Room ventilation 0 0 13 Intemal gains: Occupants @ 230 0 0 Appliances/other 0 Subtotal (lines 6 to 13) 6016 5815 Less external load 0 0 Less transfer 0 0 Redistribution 0 0 14 Subtotal 6016 5815 15 Duct loads 1-0% 0-/.l 0 0 Total room load 6016 5815 Air required (cfm) 310 203 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. WrightSOft' 2012-Oct-0809:10:04 ACGP.RightSuite® Universal 2012 12.0.07 RSU08101 Page 7 ...sers\Quick CalcMDocuments\Wrightsoft HVAC\GREEN RES I DE NCE. rup Calc = MJ8 Front Door faces: