ct Approval
Oli.Produ
USER;Public User
&iPPSa'aA.P�
Product Aeoroval Menu > Product or Application Search > gpglication List > Application Detail
'L # F1.5259-1131
application Type Revision
"ode Version 2020
%ppiication Status Approved
-omments
4rchived O V
Product Manufacturer POLYGLASS USA
Address/Phone/Email 1111 W. Newport Center Drive
Deerfield Beach, FL 33442
(954)233-1330 Ext242
malpert@polygiass.com
Authorized Signature Maury Alpert
malpert@polyglass.com
Technical Representative TECH REP
Address/Phone/Email 1111 West Newport Center Drive
Deerfield Beach, FL 33442
(866) 802-8017
uspolyglasstechnical@polyglass.com
Quality Assurance Representative QA REP
Address/Phone/Email 1111 West Newport Center Drive
Deerfield Beach, FL 33442
(888) 410-1375
uspolygiasstechnical@ poiyglass.com
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
O Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Robert Nieminen
Evaluation Report
Florida license PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 10/21/2022
Validated By John W. Knezevich, PE
9 Validation Checklist - Hardcopy Received
Certificate of Independence
FL5259 R31 COI 2020 01 COI NIEMINEN odf
Referenced standard and Year (of Standard) Standard
ASTM D1970
ASTM D226
ASTM D4798
ASTM D6163
hHpsJ/www.floridabuilding.orgfpr/pr app_dU.aspx?param=wGEVKQwtDgvbSgAaZp3Crk2vS%2feg01ip3cPzPSPEkchxoaj6Vjg1°1o2bg%3d%3d
Year
2015
2009
2011
2015
112
1/2012021
Florida Building Code Online
ASTM D6164
2011
ASTM D6222
2011
ASTM D6509
2015
FM 4474
2011
FRSA/TRI, Sixth Edition
2018
UL 1897
2015
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted
10/22/2020
Date Validated
10/26/2020
Date Pending FBC Approval
11/01/2020
Date Approved •
12/15/2020
Date Revised
12/21/2020
a o• :+.
b.. .6�.
r: r•:
del• Nuln a .,4 Mo b
^� t10R'`�
baser . P..
5259.1
Polygtass Roof
Roofing underiayments
Underlayments
Limits of Use
Approved for use in HVHZ: No
Installation Instructions
FL5259 R31 rr hoer 09 30 FINAL ER Privet ASS UNDERLAYMENTS FL5259-
R31.pdf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Robert Nieminen PE-59166
Design Pressure: +N/A/-622.5
Created by independent Third Party: Yes
Other: 1.) The design pressure in this
application relates to one particular
!;valuation Reports
FL5259 R31 AE 2020 09 30 FINAL ER POLYGLASS UNDERLAYMENTS FL5259-
R31. f
Created by independent Third Party: Yes
underlayment system for use in tile roof
systems. Refer to ER Section 5.8.3 for other
systems and associated maximum design
pressures. 2.) Refer to ER Section 5 for
other limits of use.
Back- Next:
Contact Us :: 2601 Blair Stone Road Tallahassee FL 32399 Phone: 950-487-1824
The State of Florida is an AA/EED employer. Cowright 2007-2013 state of Florida.:: Prfva� Statement :: Accessibility Statement :: Refund Statement
under Harida law, email addresses are public records. If you do not want your e-mall address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1),
Sorida provided may us d for official communication withsees censed lioenseerHowever email addresses are public S. must provide the rd N you do not emailment with an h to supply! a personal address, pleasf they have one. The e
provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please dick lielg .
Product Approval Accepts:
®= WON 99®
Credit Card
Safe
hips://wwwfloddabuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDgvbSgAaZp3Crk2vSo�2fegOlip3r,PzPSPEkchxo46Vjg1%2bglo3d%3d 212
NEMO I etc.
Certiffcate ofAuthorfzation #32455
353 Christian Street, Unit #13
Oxford, CT 06478
(203)262-9245
ENGINEER EVALUATE TEST CONSULT
REPORTEVALUATION
Polyglass USA, Inc. Evaluation Report P12060.02.09-R27
1111 West Newport Center Drive FL5259-R31
Deerfield Beach, FL 33442 Date of Issuance: 02/24/2009
(954) 233-1330 Revision 27: 09/30/2020
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use -of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for
use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described
herein have been evaluated for compliance with the 7u' Edition (2020) Florida Building Code sections noted herein.
DESCRIPTION: Polyglass Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein and
FBC 1507.1.1.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality
Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change. Acceptance of our
Evaluation Reports by the named client constitutes agreement to notify, NEMO ETC, LLC of any changes to the product(s), the
Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a complete review of its Evaluation Report relative
to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "MEMO I etc. Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then It shall be done in its entirety.
INSPEcnoN: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 17.
Prepared by:
' Q,�,� ,;,�r,�.,, •
Robert J.M. Nieminen; P.E.
=>>� .:: • ^'�
The facsimile seal appearingwas authorized by Robert Nieminen, P.E. on
Florida Registration No. s5166, Florida DCA ANE1983
"' '1.uu,.i.•*�` 09/30/2020. This does not serve as an electronicallyslgned document
CERTIFICATION OF INDEPENDENCE:
1. MEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing
products it evaluates.:
2. MEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert•Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the
evaluation reports are being issued.
4. RobertNieminen, P.E. does not have, norwill acquire, a financial interest in any other entity involved in the approval process of the product.
S. This is a building code evaluation. Neither MEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on
which this Evaluations Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that
purpose. 02019 MEMO ETC, LLC
ONEMOletc.
ROOFING COMPONENT EVAIUATION:
1. SCOPE:
Product Category:
Roofing
Sub -Category:
Underlayment
Compliance Statement:
Roof Underlayments, as produced by Polyglass USA, Inc., have demonstrated
compliance with the
following sections of the
71' Edition (2020) Florida Building Code through testing in accordance with the following
Standards.
Compliance is subject to the installation Requirements and Limitations / Conditions of Use set forth herein.
STANDARDS:2.
Section
Pro a
Standard
Year
1504.3.1
Wind resistance
FM 4474
2011
1504.3.1
Wind resistance
UL 1897
2015
1507.1.1 / R905.1.1
Material standard
ASTM D226
2009
1507.1.1,1507.2.4,-1507.2.9.2 / Material standard
ASTM D1970
2015
R905.1.1, R905.2.8.2
1507.3.3 / R905.3.3•
Material standard
FRSAf TRI, Sbcth Edition
2018
1507.11.2 / R905.11.2
Material standard
ASTM D6163
2015
1507.11.2 / R905.11.2
Material standard
ASTM D6164
2011
1507.11.2 / R905.11.2
Material standard
ASTM D6222
2011
1507.11.2 / R905.11.2
Material standard
ASTM DISS09
2015
TAS 110
Accelerated Weathering ASTM D4798
2011
Erway Examination
Reference Date
Entity Examination
Reference
Date
ERD (CST6049) Wind Uplift;
11757.08.01-1 OS/13/2001
ERD CM 6049) 30190 physicals
PLYG-SC11900.03.17
03/19/2017
ERD (TST 6049) Wind Uplift;
12776.06.02 01/16/2003
ERD CM 6049) TAS 103
PLYG-SC12115.08.17
08/08/2017
ERD list 6049) Wind Uplift
P1740.01.07 01/04/2007
ERD (TST 6049) TAS 103
PLYG-SC13035.08.17
10/31/2017
ERD CM 6049) ASTM D1970
P5110.04.07-1 04/11/2007
FM (TST 1867) Wind Uplift
3004091
01/12/2000
04/01/2019
ERD (TST 6049) Wind Uplift
P9260.03.08 03/21/2008
ICC ES (EVL 2396) IBC Compliance
ESR-1697
07/06/2017
ERD "ST 6049) Wind Uplift:
P30540.11.09-Ri 11/ao/2009
M-D (CER 1592) HVHZ Compliance
NOA 17-0614.22
J)(2OH7A
04/01/2008
ERD (7Sr6049) Tensile Adhesion
P11030.11.09-1 11/30/2009
11/30/2009
MTI (TST2508) ASTM D4798
MEMO (TST 6049) ASTM D1970
4-PLYG-18-004.03.18
03/29/2018
ERD (TST 6049) Wind Uplift'
P11030.11.09-2
P11030.11.09-3 11/30/2009
MEMO (TST6049) Wind Uplift
4L-PLYG-18-003.OL19
01/11/2019
ERD (rSf 6049) ASTM D4977
P33360.06.10 06/25/2010
MEMO (TST 6049) ASTM D6163
4S-PLYG-18-002.01.19-A
05/20/2019
ERD (TST 6049) ASTM D1970
P33370.03.11 03/02/2011
MEMO (TST 6049) ASTM D6222
4S-PLYG-18-002.05.19-C
ERD (TST W49) TAS 103
ERD (TST 6049) Tensile Adhesion
P33370.04.11 04/26/2011
MEMO (TST 6049) ASTM D1970
4j-PLYGI9SSUDL-0OA
09/10/2019
09/10/2029
10/68/2019
ERD CM 6049) ASTM D1970
P37300.10.11 10/19/2011
MEMO (TST 6049) TAS 103
4S-PLYG-18-004.10.19-G
4S-PLYG-18-004.10.3.9-1
10/08/2019
ERD (TST 6049) TAS 103
P40390.08.12-1 08/06/2012
MEMO list 6049) TAS 103
MEMO (TST 6D49) TAS 103
4S-PLYG-18-0D4.10.19-L
10/09/2019
ERD (TSr6049) Tensile Adhesion
P40390.08.12-2 08/07/2012
09/11/2022
MEMO (TST 6049) TAS 103
41-PLYG 19-SSUDL-01.A
10/10/2019
ERD (TST 6049) Tensile Adhesion
C41420.09.12-3
03/04/2013
NEMO (TST 6049) TAS 103
4S-PLYG-18-004.12.19-F
12/18/2019
ERD (TST 6049) WindUpldt'
P39680.03.13
P45370.04.13 04/26/2013
MEMO (TST 6049) TAS 103
4j-PLYG-19-55UD1-02.A
01/02/2020
ERD (TST 6049) ASTM D1976
Wind Uplift
P1738.02.07-R2 04/29/2013
MEMO (TST 6049) ASTM D1970
45-PLYG-18-004.0L20.H
01/14/2020
ERD (TST 6049)
Wind Uplift
11757.04.01-1-R1 04/30/2013
MEMO (TST 6049) ASTM D1970
45-PLYG-18-004.OL20.K
01/14/2020
ERD UST 6049)
ERD CM 6049) ASTM D6164
P37590.03.13-3A 05/06/2013
MEMO (TST 6049) TAS 103
4s-PLYG-18-004.01.20.A
01/16/2020
ERD (TST 6049) ASTM 06509
P37590.03.13-1-R1 06/26/2013
MEMO (TST 6049) ASTM D5222
PLYG �� R1
02/07/2020
ERD (TST 6049) Wind Uplift
P41630.08.13 08/06/2013
09/04/2013
MEMO (T5T 6049) ASTM D6222
MEMO CM 6049) TAS 103
PLYG-SC15855.05.20.A
OS/29/2020
ERD (TST 6049) ASTM D4601
P45940.09.13
P11751.05.03-R1 IV26/2013
MEMO CM 6049) TAS 103
4j-PLYG 20-SSUDL-01
07/06/2020
ERD (TST 6049) Wind Uplift
P11781.11.03-RS 11/26/2013
MEMO (r5T 6049) ASTM. D6222
4q-PLYG-19-SSMB8-05.A
07/23/2020
ERD (TST 6049) Wind Uplift
30/9D
05/12/2014
MEMO W 6049) ASTM D479SID1623
4j-PLYG-19 SSUDL-05.A
09/10/2020
(TSi 6D49) Physicals
ERD 6049) Tensile adhesion
ERD CM
(TST103
6020.09.14 5 09/08/2014
MEMO OST 6049) ASTM D1970
4j-PLYG-20-SSUDL-O5.A
09/30/2020
09/30/Z020
ERD (TsT 6049) Tensile adhesion
6020.09.14-6 09/08/2014
MEMO UST 6049) TAS
MEMO M7 6049) TAS 103
4j-PLYG-20 SSUDL-0S.0
4j-PLYG-20-SSUDL-11
09/30/2020
ERD (TST 6049) Tensile adhesion
P46520.10.14 10/03/2014
Evaluation Report P12060.02.09-R27
MEMO ETC, LLC.
cerdf Bate of Authorization #32455
7TM EDITION (2020)
FBC MOderlay EVALUATION
FL5259-R31
Revision 27. 09/30/2020
Polyglass Roof Undedayments
Page 2 of 17
Entity
Examination
Reference
1. Date
ERD (TST 6049)
ASTM D1970/D4798
P43290.10.14
10/17/2014
ERD (TST 6049)
TAS 103 -
PLY(iSC7550.03.15
03/24/2015
ERD (TST 5049)
Tensile adhesion
P40390.04.15
04/03/2015
ERD UST 6049)
TAS 103
P44360.10.14-R1
05/18/2015
ERD (TST 6049)
Wind Uplift
PLYGSC8905.05.16-1
05/17/2026
ERD (nT 6049)
ASTM D1970
PLYGSC10130.06.16-1
06/27/2016
ERD (TST 6049)
Tensile adhesion
PLYG-SC10130.06.16-2
06/27/2016
ERD CM 6049)
TAS 103
PLYG-SC10130.06.16-3
06/27/2016
ERD (T5r GD49)
ASTM D1970/D4798
PLYG SC8080.07.16
07/16/2016
ERD (W 6049)
wind Uplift
PLYG-SC12025.10.16
10/12/20%
ERD (TST W49)
TAS 103
PLYG-SC13040.12.16
12/27/2016
PRODUCT4.
DESCRIPTION:
4.1
4.2
4.3
4.4
4.5
4.6
4.7
4.8
4.9
4.10
4.11
4.1;
4.1'
4.14
*ONEMOjetc.
Entity,Examination Reference Date
PRI (TSr 5878) Tensile Adhesion PRI01111 04/08/2002
PRI (W 5878) TAS 103 PUSA-018-02-01 07/14/2003
PRI (TbT 5878) TAS 103 PUSA-035-02-01 09/29/2006
PRI (TST 5878) TAS 103 PUSA-055-02-02 12/10/2007
PRI (TST 5878) ASTM D6222 PUSH 061-02-02 01/28/2008
PRI (M 5878) ASTM D6164 PUSA-088-02-01 07/29/2009
Polyglass USA P/L Affidavit Mule -Hide Cross ug 03/01/2008
Polyglass USA Materials Affidavit Polystick Compound 08/18/2011
UL (QUA9625) Quality Control Service Confirmation (FL) 09/13/2018
UL (QUA9625) Quality Control Service Confirmation (TX) 11/07/2019
UL (QUA9625) Quality Control Florida BQS Current
Product
Material Standard
Plants)
Description
Elastobase
ASTM D6163
FL
Fiberglass -reinforced, SBS modified bitumen base sheet
Elastobase P
ASTM D6164
FL
Polyester -reinforced, SBS modified bitumen base sheet
Elastoflex S6 G
ASTM D6164
FL, PA
Polyester -reinforced, SBS modified bitumen cap sheet
FRSA/TRI 09-18
Elastoflex S6 G FR
ASTM D6164
FL
Polyester -reinforced, SBS modified bitumen cap sheet
FRSA/TRI 09-18
HydraGuard Dual Pro
ASTM D1970
FL
Nominal 60-mil thick dual -layer rubberized asphalt
waterproofing membrane, fiberglass reinforced, with a
polyester fabric surface
HydraGuard Tile Pro
ASTM D1970
FRSA/TRI 09-18
FL
Nominal 60-mil thick dual -layer rubberized asphalt
waterproofing membrane, fiberglass reinforced, with a
polyester fabric surface
Mule -Hide SA-APP cap sheet
ASTM D6222
FL
Polyester -reinforced, APP modified bitumen cap sheet
FRSA/TRI09-18
Mule -Hide SA-APP Cap Sheet
ASTM D6222
FL
Polyester -reinforced, APP modified bitumen cap sheet
(FR)
FRSA/TR109-18
ASTM D6222
FRSA/TRI 09-18
FL
Polyester -reinforced, APP modified bitumen cap sheet for
use as an alternate to Heat Applied "Cap Sheet" in the
"Two Ply System" from FRSA/TRI Florida High Wind
Concrete and Clay Roof Tile Installation Manual, Sixth
Polyflex G
Edition beneath mechanically fastened or adhered tile
roof systems
ASTM D6222
FRSA/TR109-18
FL
Polyester -reinforced, APP modified bitumen cap sheet for
use as an alternate to Heat Applied "Cap Sheet" in the
"Two Ply System" from FRSA/TRI Florida High Wind
Concrete and Clay Roof Tile Installation Manual, Sixth
Polyflex G FR
Edition beneath mechanically fastened tile roof systems
ASTM D62Z2
FRSA/TRI 09-18
FL, TX
Polyester -reinforced, APP modified bitumen cap sheet
Polyflex SAP
Polyflex SA P FR
ASTM D6222
FRSA/TRI 09-18
ASTM D6509
FL, TX
FL
Polyester -reinforced, APP modified bitumen cap sheet
Fiberglass -reinforced, APP modified bitumen base sheet
Polyglass Base
ASTM D4601
AL
Fiberglass -reinforced, asphaltic base sheet
Polyglass 62 Base Sheet
evajuauon napu•�r,
NEMO ETC, LLC. FL5259-R31
Certr tcate ofauthorkaffon #32455 TTM EDITION ass Roof Underlayments FBC NON-HVHZ EVALUATION Revision 27-. 09/30/2020
PolyglWass Page 3 of 27
M
4.15
4.16
4.17
4.18
4.19
4.20
4.21
OMEMO ! etc.
PRODUCT
Product
Material Standard
Plants)
Description
Polystick IR-Xe
ASTM D1970
FL, PA, TX
Nominal 60-mil thick rubberized asphalt waterproofing
membrane, glass fiber reinforced, with an aggregate
surface
Polystick MTS Plus
ASTM D1970
FL, NV,
Nominal 60-mil thick rubberized asphalt waterproofing
-- „�-----
FRSA/TRI 09-18
PA, TX
membrane, glass fiber reinforced, surfaced with
polyolefinic film surface
Polystick MU-X
ASTM D19701
FL, NV, PA
Nominal 54-mil thick dual -layer rubberized asphalt
waterproofing membrane, fiberglass reinforced, with a
polypropylene film surface
Polystick TU Max
ASTM D1970
FL, PA, TX
Nominal 60-mil thick rubberized asphalt waterproofing
FRSA/TRI 09-18
membrane with a 190 g/mz polyester fabric surface
Polystick TU P
FRSA/TRI 09-18
FL, PA, TX
Nominal 130-mil thick rubberized asphalt waterproofing
membrane, glass fiber/polyester reinforced, with a
granular surface
Polystick TU Plus
ASTM D1970
FL, PA, TX
Nominal 80-mil thick rubberized asphalt waterproofing
FRSA/TRI 09-18
membrane, glass fiber reinforced, with a polyester fabric
surface
Polystick XFR
ASTM D1970
NV, TX
Nominal 80-mil thick rubberized asphalt waterproofing
FRSA/TRI 09-18
membrane, glass fiber reinforced, surfaced with a
textured film surface
S. LwTATioNs,
5.1 This is a Building Code Evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for
any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless
retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami -Dade Counties).
5.3 This Evaluation Report pertains to above -deck roof components. Roof decks and structural members shall be in accordance with
FBC requirements to the satisfaction of the Authority Having Jurisdiction.
5.4 This Evaluation Report does not include.evaluation of fire classification. Refer to FBC 1505 for requirements and limitations
regarding roof assemblyfireclassification. Refer to FBC 2603 for requirements and limitations concerning the use of foam plastic
insulation.
5.5 Polyglass Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within
FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this
evaluation combined with supporting data for the prepared roof covering.
1 Polystiek MU X has been found through comparative testing to have a lessercoeff cient of friction than A5TM D226 roafng felt in a dry condition, tested at standard
laboratory conditions. Agreement between purchaser and seller, as set forth in Section 4.3, Note 1 ofASTM D1970-25, should be established p resistance.
Report 02.09 R27
NEMO ETC, LLC. FL5259_1132
Cermcate ofMthorkatlon #32455 7-kDITION (2020) FBC NON-HVHZ EVALUATION
Polyglass Roof Undedayments Revision 27,.09/30/2020
Page 4 of 17
OMEMO jetc.
5.6 Allowable Roof Covers:
Asphalt
Clay and Concrete Tile
Metal
Slate or
Wood
Slate4Vpe.
Underlayment
Shingles
Mechardeal
Adhesive-
Panels
Shingles
Shingles
Shingles
Shakes (1507.9)
(15072)
Attach
Set .
(1607.4)
(2507.5)
- (1W.7)
- (107.8)
Yes
Yes
Yes
Yes.
Yes
Yes
Yes
Yes
Elastobase
(Altemmeto
(as Base Sheet,
(as Base Sheet,
(Altemateto
(Altemateto
(Altemateto
(Alternate to D224
(Altemateto D226,
D226, Type 11)
See5.83)
SeeS.8.3)
D226, Type 11)
D226, Type 10
D226,Tvpen)
Type 11)
Type 11)
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Elastobase P
(Alternate to
(as Base Sheet,
(as Base Sheet
(Altemateto
(AbmatotD
(Altemateto
(AttematetoD22%
(Alternate to D226,
0226,Typell)
See S33)
See 5.&3)
D226,TVpe 11)
02261TW-11)
D226,Typell)
Type 11)
Type 11)
Polyglass Base
No
Yes
(asBaseSheet,
Yes
(as Base Sheet,
No
No
No
No
No
Sw5.8.3)
SeeS.8,3)
Polyglass G2 Base
No
Yes
(as Base Sheet,
Yes
(as Base Sheet
No
No
No
No
No
See 523)
see S.8.3)
Elastoflex S6 G
No
Yes
Yes (see 5.6-1)
No
No
No
No
No
Elastoflex S6 6 FR
No
Yes
No
No
No
No
No
N a
—
Yes
Yes
HydraGuard Dual Pro
Yes
No
No
Yes
Yes
Yes
anintstrips,1507.1.13
aointstripS,150711.3
/fl90S.1L3)
111905.2-13)
Yes
Yes
HydraGuard Tile Pro
Yes
Yes
Yes
(See 5.6.1)
Yes
Yes
Yes
ljoint strips, 1507.1.L3
/ RM.1-13)
(Joint strips, 2507-tl.3
/R90S-LL3)
Mule -Hide SA-APP Cap Sheet
No
Yes
Yes
(See 5.6.1)
No
No
No
No
No
-et (FR)
Mule -Hide SA-APP Cap She
No
Yes
Yes
(see 5.6.�) ]�
No
No
No
No
Polyflex G
No
Yes
Yes
(See 5.6.1)
No
No
No
No
No
Polyflex G FR
No
Yes
No
No
No
No
No
No
Polyflex SAP
No
Yes
Yes
(See 5.6.1)
No
No
No
No
No
Polyflex SA P FR
No
Yes
Yes
(See 5.6.1)•
No
_
No
No
No
No
Yes
Yes
Polystick 1R-Xe
Yes
No
No
No
No
Yes
Goint strips, 2507.1.L3
/R90S.LL3)
(joint strilps, 1507.1.1.3
I /RSGS.LL3)
Yes
Yes
Polystick MTS Plus
Yes
Yes
No
Yes
Yes
Yes
(joint strips, 15D7.1.L3
M5.LL3)
(Joint strips, 1507.1.LS
/RMS.LLS)
Yes
Yes
Polystick MU-X
Yes
No
No
Yes
Yes
Yes
(Joint strips, 1507.1.L3
R905.Ix3)
anyint strips. 1507-2.L3
/R90S.LL3)
Yes
Yes
No
Yes
Yes
Yes
Yes
No
Goint strips, M7.LL3
flo1r1tsWpr6=3 7-L1
PolystickTU Max
(See 5.6.1)
R9051.1.3)
/R90-113)
Yes
Yes
No
Yes
Yes
No
No
No
Goint strips, 1507.L13
GaintShiPs,1507-LI3
PolystickTU P
(See 5.6.1)
R905.2.L3)
/8905.I.L3)
Yes
Yes
Yes
Yes
Yes
Yes
Yes
0o1ntstffps,1507.LL3
Yes
(Joint strips, M7-1-L3
PolysticickTU Plus
(See 5.6.1)
R90S.'LI3)
11905.1.1.3)
Yes
Yes
Yes
Yes
No
Yes
Yes
Yes
gointstdps, 1507.1.t3
Goint strips, 1SM-LI-3
Polystick XFR
I R905.L23)
RSMLL3)
Evaluation Report P32060-07-09-1127
MEMO ETC, I.I.C. FL5259-R31
certifkate ofAuthorkation #32455 rH EDITION (2020) FBC NON-HV"Z EVALUATION Revision 27:09/3012020
polyglass Roof Underlayments; Page 5 of 17
5.6.1 Adhesive -set tile is limited to use of the following underlayment / tile -adhesive combinations.
CAB I:E.1A.,i1LlOWABLE'UNbERiA17N1ENL•=�710E-ADHES117E.COMBIh1A'f1011115z� '
Underlayment
Adhesive
Florida Product Approval
PolystickTU Max or PolystickTU Plus
DAP Foam "Touch'n Seal • ��
StormBond Roof Tile Adhesive
FL14506
HydraGuard Tile Pro, Polyflex SA P, Polystick TU Max, Polystick TU P or Polystick
Dupont `Tile BondTM Roof Tile
FL22525
TU Plus
Adhesive"
Elastoflex S6 G, HydraGuard Tile Pro, Mule -Hide SA APP Cap Sheet, Mule -Hide SA
ICP Adhesives and Sealants
APP Cap Sheet (FR), Polyflex G, Polyflex SA P, Polyflex SA P FR, Polystick TU Max,
"Polyset® AH-160"
FL6332
Polystick TU P or Polystick TU Plus
Elastoflex S6 G, HydraGuard Tile Pro, Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-
ICP Adhesives and Sealants
APP Cap Sheet (FR), Polyflex G, Polyflex SA P, Po[yflex SA P FR, Polystick TU Max,
"Polyset® RTA-1"
FL6276
Polystick TU P or Polystick TU Plus
5.7 Allowable Substrates:
• :'�ABLE;�
�.SUBSrAA:I3B7IONS FOR IIDHEREDiUNQERWYMEl�i1�r `r
.
Substrates (designed
to meet wind loads for project)
Underlayment
Application
Type
Primer
Material(s)
HydraGuard Dual Pro,
HydraGuard Tile Pro, Polystick IR-
Xe, Polystick MTS Plus, Polystick
Deck /
sheathing
(Optional) ASTM
D41
plywood, OSB, Southern Yellow Pine or Huber Engineered
Woods "ZIP System" Panels
ASTM D41
structural concrete
MU X, Polystick TU Max, ;
PolystickTU P, PolystickTU Plus,
Polystick XFR, Mule -Hide SA-APP
self
adhering
Insulation
(Optional) ASTM
p41 or WB-3000
ASTM C1289 Type 11 Class 1 polyisocyanurate, ASTM
C1289 Type V polyisaLyanurate composite, DensDeck
Prime or SECUROCK Gypsum -Fiber Roof Board
Cap Sheet, Mule -Hide SA APP
Cap Sheet (FR), Polyflex SA P or
Polyflex SA P FR
Base Sheet
N/A
Type 11 felt, Elastobase, Elastobase P or Mule-
Hide ail Base
Hide Nail Base
Deck
ASTM D41
structural concrete
insulation
(Optional) ASTM
D41
DensDeck Prime or SECUROCK Gypsum -Fiber Roof Board
Elastoflex S6 G or Elastoflex S6 G
hot asphalt
Base Sheet
N/A
ASTM D225, Type II felt Elastobase, Elastobase P, Mule -
Hide Nail Base or Polyglass G2 Base
FR
Deck
ASTM D41
structural concrete
Insulation
(Optional) ASTM
D41
DensDeck Prime or SECUROCK Gypsum -Fiber Roof Board
Polyflex G or Polyflex G FR •
torch-
applied
Base Sheet
N/A
Elastobase, Elastobase P, Mule -Hide Nail Base, Polyglass
G2 Base or Polyglass Base
2 Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for overturning Moment Resistance Performance-
Evaluation
ETC; LtC Evaluation Report P12060.02.09-R27
NEM
CertljLL hvrizaUon #32455 77H EDITION (2020) FBC NON-HVHZ EVALUATION FL5259-R31
Polyglass Roof Underlayments Revision 27. 09/30/2020
Page 6 of 17
OMEMO I etc.
5.8 Attachment Limitations:
5.8.1 For use under mechanically attached NON TILE prepared roof coverings, attachment shall be in accordance with the
manufacturer's installation instructions, but — for mechanically attached underlayments or base sheets - not less than FBC
1507.1.1 or R905.1.1.
5.8.2 For use under the roof systems, attachment shall be in accordance with the manufacturer's installation instructions, but —
for mechanically attached base sheets - not less than:
• FRSA/TRI Florida High Wind Concrete and Clay Roof rile Installation Manual, Sixth Edition, Appendix A, Table 1(for Two -
Ply Asphalt Applied Hot Mop Underlayment)
or
• Section S.8.3 herein (for other underlayment systems).
5.8.3 Wind Resistance for Underlayment Systems in Tile Roof Applications:
The following wind uplift limitations apply to underlayment systems that are not prescriptive in the FRSA/TRI Florida High
Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition. The Maximum Design Pressure is the result of testing
for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1
margin of safety per FBC 1504.9 has already been applied).
5.8.3.1 Direct -to -Deck:
The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI Florida High
Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1A or the critical (highest) design -
pressure determined in accordance with FBC IL609 or FBC Residential Chapter 3.
#1 Maximum Design Pressure = -52.5 psf:
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Joints: Min. 4-inch wide strips of Elastoflex SAN over all OSB joints
Base Ply: Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, PolystickTU Max, Polystick
TU P or PolystickTU Plus, self -adhered.
#2 Maximum Design Pressure = -90 asf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer. kone
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#3 Maximum Design Pressure=-97.5 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG100 or ASTM D41
Base Ply. (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, PolystickTU Max, Polystick
TU P or Polystick TU Plus, self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x 1%" ring shank
nails through 32 ga.,1-5/8" diameter tin caps spaced 12-inch o.c.
#4 Maximum Design Pressure = -10S psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: WB-3000
Base PIy. (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SAAPP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, PolystickTU Max, Polystick
TU P or Polystick TU Plus, self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x 1'/a" ring shank
nails through 32 ga.,1-5/8" diameter tin caps spaced 12-inch ox.
Evaluation Report P420SM02.09-R27
NEMO ETC, LLC. FL5259-RBI
certj/icateofAutharization #32455 7-EDITION (2020) FBC NO N-HVHZ EVALUATION
20
Polyglass Roof Underlayments Revision 27: 0
• Paggee 7 7 oof f 17
MEMO I etc.
#5 Maximum Design Pressure = -135 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: (Optional) PG100 or ASTM D41
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Joints: Min. flinch wide strips of Elastoflex SA V over all plywood joints.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, PolystickTU Max, Polystick
TU P or PolystickTU Plus, self -adhered.
#6 Maximum Design Pressure = -31S psf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG100 or ASTM D41
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: HydraGuard Tile Pro, Mule -Hide SA-APP Cap Sheet, Mule -Hide SA APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR,
PolystickTU Max, PolystickTU P or PolystickTU Plus, self -adhered.
#7 Maximum Design Pressure = -622.S psf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG100 or ASTM D41
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#8 All other direct -deck, adhered Underlayment systems beneath the roof systems carry a Maximum Design Pressure of -45 psf.
5.8.3.2 Mechanically -Attached Base Sheet:
The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI Florida High
Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1A or the critical (highest) design
pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1 design
pressure determined in accordance with'FBC 3.609 or FBC Residential Chapter 3. Elevated pressure tones shall employ an
attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used.
methods are ANSI/SPRI WD1, FM loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing
Application Standard RAS 137. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM
Loss Prevention Data Sheet 1-29 (February 2020) for enhancements.
#9 Maximum Design Pressure = -30.0
Deck: Min.15/32-inch OSB to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: 51astobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: 11L ga. x 1.25Anch long x 1-inch head diameter round metal cap nails
Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at two (2) equally spaced staggered center rows.
Base Ply: (optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P Fit, Polystick TU Max, Polystick
TU P or PolystickTU Plus, self -adhered.
#10 Maximum Design Pressure = -37.5 psf*:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: 11 ga. x 1.25-inch long x 1-inch head diameter round metal cap nails
Spacing: 6-inch o.c. at the 34nch wide side laps and 6-inch o.c. at two (2) equally spaced staggered center rows.
Base Ply., (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, PolystickTU Max, Polystick
TU P or PolystickTU Plus, self -adhered.
#11 Maximum Design Pressure=-37.5 psf*:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: one (1) or two (2) layers ASTM 13226, Type II felt
Fasteners: ' 11 ga. x 1.254rich long x 1-inch head diameter round metal cap nails
Spacing: GAnch o.c. at the 3-inch wide side laps and 12-inch o.c. at two (2) equally spaced. staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt.
Evaluation Report P32060.02.09-R27
NEMO ETC, LLC. i FL5259-R31
Certffwte ofAuMarkadon #32455 7" EDITION (2020) FBC NON-HVHZ EVALUATION Polygiass Roof UnderlayRevisiod 27: 09/30/2020
meMs
Page 8 of 17
OMEMO etc.
#12 Maximum Design Pressure = 45 psf*:
Deck: Min.19/32-inch. plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet. One (1) layer ASTM D226, Type 11 felt
Fasteners: 11 ga. x 1.25-Inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 4-inch o.c. at the 2-inch wide side laps and 4-inch o.c. at two (2) equally spaced staggered center rows.
Base Ply: (Optional; for use with self -adhering underlayment only) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#13 Maximum Design Pressure = -45 psf*:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Two (2) layers ASTM D226, Type II felt
Fasteners: 11 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diametertin caps
Spacing: 94nch o.c. at the 2-inch wide side laps and 9-inch o.c. at two (2) equally spaced staggered center rows.
Base Ply: (Optional; for use with self -adhering underlayment only) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, PolyflexSA P FR, PolystickTU Max, Polystick
TU P or Polystick TU Plus, self -adhered or Elastoflex S6 G, applied in full mopping of hot asphalt.
#14 Maximum Design Pressure = -45 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing. 9-inch o.c. at the 2-inch wide side laps and 1.8-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#15 Maximum Design Pressure =-45.0 psf:
Deck: APA rated, 7/26 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: 12 ga. annular ring shank nails with 1-5/8" diameter tin caps
Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows.
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA APP Cap Sheet (FR), Polyflex SAP, Polyflex SAP FR, PolystickTU Max, Polystick
TU P or PolystickTU Plus, self -adhered.
#16 Maximum Design Pressure = -45.0 psf:
Deck: 0A rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase (sand top surface)
Fasteners: 12 ga. annular ring shank nails with 1-5/8" diametertin caps
Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt.
#17 Maximum Design Pressure = -45.0 psf:
Deck: APA rated,.7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: 12 ga. annular ring shank nails with 1-5/8" diameter tin caps
Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-'inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Polyflex G, torch -applied.
#18 Maximum Design Pressure = -52.5 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners., Simplex MAX( Cap Fasteners
Spacing: 94nch o.c. at the 2-inch wide side laps and 12-inch o.c. at two {2) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
Evaluation Report P12060.02.09-R27
NEMO ETC, LLC. Ft5259-R31
cenifuoteofAuthonzation ✓<32455 7TM EDMON (2020) F8C NON-HVH2 EVAWATION
Polyglass Roof Underlayments Revision 27: 0913012020
Page 9 of 17
ONEMOletc.
#19 Maximum Design Pressure = -S2.5 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nall Base (poly -film top surface)
Fasteners: Simplex Original Cap Nails
Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at four (4) equallyspaced staggered center rows.
Base Ply: (Optional) Polystick MT5 Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#20 Maximum Design Pressure = -S2.5 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex Original Cap Nails
Spacing: G-inch o.c. at the 3-inch wide side laps and 6-inch o.c. atfour (4) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or Polyfiex G, torch -applied.
#21 Maximum Design Pressure = -60 psf:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: 11 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing. 8-inch o.c. at the 44inch wide side laps and 8-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#22 Maximum Design Pressure = -60 psf:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction,
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: OMG #12 Standard Roofgrip with OMG Flat Bottom Metal Plates
Spacing. i2-inch o.c. at the 4-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#23 Maximum Design Pressure =-60.0 psf:
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathingto meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 8-inch o.c. at the 3-inch wide side laps and 8-inch o.c. at three (3) equally spaced staggered center rows.
Primer: 0G100 or ASTM D41 primer applied to stress plates.
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#24 Maximum Design Pressure = -60.0 psf:
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathingto meet project requirements to satisfaction of Authority Having
jurisdiction.
Base Sheet: Elastobase (sand top surface)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 8-inch o.c: at the 3-inch wide side laps and 9-inch o.c. at three {3) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt.
#25 Maximum Design Pressure =-60.0 psf:
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: Simplex MAXX Cap Fasteners
Spacing: ?-inch o.c. at the 3-inch wide side laps and 8-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Polyflex G, torch -applied.
Evaluation Report P12060.02.09-R27
NEMO ETC, U.C. FL5259-R31
ceroftate ofAathorkation #32455 7T" EDITION {2020) FBC NON-HVHZ EVALUATION Revision 27. 09/30/2020
Polyglass hoof Undedayments page 10 of 17
ONEMO I etc'.
#26 Maximum Desian Pressure = -67.5 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet; Polyglass G2 Base or Polyglass Base (requires use of torch -applied underlayment)
Fasteners: 12 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 8-inch o.c. at the flinch wide side laps and 8-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch -applied.
#27 Maximum Design Pressure = -67.5 psf:
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 190° into the holes of the plate, parallel to
the width direction of the sheet.
Spacing: 12-inch o.c, at the flinch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Primer: (Optional) PG100 or ASTM D41 primer applied to stress plates.
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#28 Maximum Design Pressure = -67.5 psf:
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet: Elastobase (sand top surface)
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180° into the holes of the plate, parallel to.
the width direction of the sheet.
Spacing: 12-inch o.c. at the 4Pnch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment; Elastoflex S6 G, applied in full mopping of hot asphalt.
#29 Maximum Design Pressure = -67.5 psf:
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet; Elastobase or Polyglass Base
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180° into the holes of the plate, parallel to
the width direction of the sheet.
spacing: 12-inch o.c. at the flinch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Polyflex G, torch -applied.
#30 Maximum Design Pressure = -75 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: polyglass G2 Base or Polyglass Base (requires use of torch -applied underlayment)
Fasteners: Dekfast #14 with Dekfast Hex plates, OMG #14 HD with OMG 3" Galvalume Steel Plates, OMG Roofgrip #14 with OMG Flat
Bottom Plates (AccuTrac), Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap Fasteners
Spacing; 10-inch o.c. at the 4-inch wide side laps and 10-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch -applied.
#31 Maximum Design Pressure = -90 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c. at the 2-Inch wide side laps and 6-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
432 Maximum Design Pressure = -90 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly film surface for torch -applied cap)
Fasteners: 4MG #12 Standard Roofgrip or OMG #14 Heavy Duty with OMG 3" Round Metal Plates or OMG Flat Bottom Metal Plates
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
Evaluation Report P12060.02.09-R27
NEMO ECC, LLC. FL5259-R31
certyicate ofAuthorizatlon #32455 11- EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 09/30/2020
Polyglass Roof Underlayments
Page 11 of 17
MEMO I etc.
#33 Maximum Design Pressure = -90 psf:
Deck: Min.15/32-inch plywood to meet project requirements'to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface)
Fasteners: Trufast #12 DP or Trufast #14 HD with Trufast 3" Metal Insulation Plates
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hotpsphalt.
#34 Maximum Design Pressure = -90 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction,
Base Sheet: Polyglass G2 Base or Polyglass Base (requires use of torch -applied underlayment)
Fasteners: Dekfast #14 with Dekfast Hex plates, OMG #14 HD with OMG 3" Galvalume Steel Plates, OMG Roofgrip #14 with OMG Flat
Bottom Plates (AccuTrac), Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap Fasteners
Spacing: 9-inch o.c. at the 4-inch wide side laps and 9-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch -applied.
#35 Maximum Design Pressure = -90.0 psf:
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Mute -Hide Nail Base (poly -film top surface)
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180" Into the holes of the plate, parallel to
the width -direction of the sheet
Spacing: 9-inch o.c. at the 2-1nch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Primer. PG100 or ASTM D41 primer applied to stress plates.
Base Ply: (Optional) Polystick MTS Pius, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA APP Cap Sheet (FR); Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#36 Maximum Design Pressure = -90.0 psf.
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase (sand top surface)
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180' into the holes of the plate, parallel to
the width -direction of the sheet
Spacing: 9-inch o.c. at the 2-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt.
#37 Maximum Design Pressure = -90.0 psf:
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathingto meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 1W into the holes of the plate, parallel to
the width -direction of the sheet
Spacing: 9-inch o.c. at the 2-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Polyflex G, torch -applied.
#38 Maximum Design Pressure = -97.5 psf:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: if ga. x L25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 44nch o.c. at the 44nch wide side laps and 4-inch o.c. at four (4) equally spaced staggered center rows.
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, PolysUckTU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
Evaluation Report P17060.02.09-R27
MEMO ETC, LLC. FL5259-R31
ceytificoteofAuthorfzaUba#32455 7- EDITION (2020) FBc NON-HVHZ EVALUATION Revision 27: 09/30/2020
Polyglass Roof Undedayments page 12 of 17
ONEMOletc.
#39 Maximum Design Pressure = -97.5 psf:
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly film top surface)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows.
Primer:. PG100 or ASTM D41 primer applied to stress plates.
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, PolyflexSA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#40 Maximum Design Pressure=-97.5 psf:
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet: Elastobase (sand top surface)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c. at the 44nch wide side laps and 64nch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt.
#41 Maximum Design Pressure = -97.5 psf:
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 64nch o.c. at the 4-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Polyflex G, torch -applied.
#42 Maximum Design Pressure = -105 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: Crinch o.c. at the 2-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastaflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#43 Maximum Design Pressure=-105.0 psf:
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180" into the holes of the plate, parallel to
the width -direction of the sheet
Spacing: 6-inch o.c. at the 4-inch wide side laps and 5-inch o.c. at three (3) equally spaced staggered center rows.
Primer. PG100 or ASTM D41 primer applied to stress plates.
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA APP Cap Sheet, Mule -Hide SA-APP Cap sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or PolystickTU Plus, self -adhered.
#44 Maximum Design Pressure = -105.0 Of:
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase (sand top surface)
Fasteners. TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate Installed 180' into the holes of the plate, parallel to
the width -direction of the sheet
-inch o.c. at three (3) equally spaced staggered center rows.
Spacing: &Inch o.ca at the 4-inch wide side laps and 6
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt.
i
Evaluation Report P12060.02.09-RZ7
NEMO ETC, LLC. FL5259-R31
Cerdfkate opAuthorkaffon #324S5 7'" E�n10N (2020) FBC NON-t1VHZ EVALUATION Revision 27: 09/30/2020
Polyglass Roof Underlayments Page 13 of 17
OMEMO I etc.
#45 Maximum Design Pressure = -105.0
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet., Elastobase or Polyglass Base
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180" into the holes of the plate, parallel to
the width -direction of the sheet
Spacing: 6-inch o.c. at the flinch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Polyflex G, torch -applied.
#46 Maximum Design Pressure = -112.5 psf:
Deck: Min,19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: 11 ga. x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 6-inch o.c. at the flinch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows.
Primer: PG100 or ASTM D41 primer at all tin -caps
Base Ply: Polystick MTS Plus, self -adhered
Underlayment: Mule -Hide SA APP Cap Sheet, Mute -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#47 Maximum Design Pressure = -120 psf
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch- applied cap)
Fasteners: OMG #12 Standard Roofgrip or OMG #14 Heavy Duty with OMG 3" Round Metal Plates or OMG Flat Bottom Metal Plates
Spacing: 6Anch o.c. at the 4-inch wide side laps and 6-inch o.c. at five (5) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#48 Maximum Design Pressure = -120 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface)
Fasteners: Trufast #12 DP or Trufast #14 HD with Trufast 3" Metal Insulation Plates
Spacing: 6-inch o.c. at the flinch wide side laps and 6-inch o.c. at five (5) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt.
#49 Maximum Design Pressure=-127.5 t►sf:
Deck: APA rated, 19132 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of authority
Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with one (1) screw per plate, in the center hole.
Spacing: 9-inch o.c. at the 4-inch wide side laps and 9-inch o.c. at four (4) equally spaced staggered center rows.
Primer: PG100 or ASTM D41 primer applied to stress plates.
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA APP Cap Sheet, Mule -Hide SA APP Cap Sheet (FR), Polyflex SA P, PoPAex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#50 Maximum Design Pressure=-127.5 asf
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet: Elastobase (sand top surface)
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with one (1) screw per plate, in the center hole.
Spacing: 9-inch o.c. at the flinch wide side laps and 94nch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt.
#51 Maximum Design Pressure = -127.5 psf:
heathing to meet project requirements #o satisfaction of Authority
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB s
Having Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with one (1) screw per plate, in the center hole.
Spacing: 9-inch o.c. at the 4-4inch wide side laps and 9-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Polyflex G, torch -applied.
Evaluation Report P12060.02.09-R27
NEMO ETC, LLC FL5259-R31
CertUlwte ofAothorimbOn #32455 7m EDITION (2020) FBc NON-HVHZ EVALUATION Revision 27: 09/30/2020
Polyglass Roof Underlayments Page 14 of 17
OMEMO I etc.
5.9 Exposure Limitations:
Underlayment
'Prepared Roof Cover
Installation Type
Maximum
Exposure (days)
Elastobase, Elastobase P, Polyglass G2 Base or Polyglass Base
Mechanically attached
30
Polystick IR-Xe or Polystick MUX
Mechanically attached
90
HydraGuard Dual Pro, HydraGuard Tile Pro, Polystick MTS Plus, Polystick TU Max, Polystick
TU P, Polystick TU Plus or Polystick XFR
Any type (per Table 1)
180
I
Elastoflex S6 G, Elastoflex S6 G FR, Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap
Sheet (FR), Polyflex G, Polyflex G FIR, Polyflex SA P or Polyflex SA P FR
Adhesive -set tile roof system
180
Mechanically attached
UNLIMITED
5.10 Tile Slippage Limitations: When loading roof tiles on the underlayment in direct -deck tile roof assemblies, the maximum roof
Onne shall be
a as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles.
Underlayment
rile Profile
Staging Method
Maximum Staging Slope
Elastoflex S6 G or S6 G FR
Flat or Lugged
6-tile stack (4 over 2)
Prohibited without battens
HydNGuard Tile Pro
Flat or Lugged
6-tile stack (4 over 2)
7:12
Polyflex G or G FR
Flat or Lugged
6-tile stack (4 over 2)
4:12
Polyflex SA P or SA P FR
Flat or Lugged
6-tile stack (4 over 2)
4-12
Polystick MTS Plus
Flat
6-tile stack (4 over 2)
5:12
Lugged
6-tile stack (4 over 2)
4:12
Polystick TU Max
Flat
6-tile stack (4 over 2) or jo-tile stack
7:12
Lugged
6-tile stack (4 over 2)
7:12
Lugged
20-tile stack
6:12
Polystick TU P
Flat or Lugged
6-tile stack (4 over 2)
7:12
Polystick TU Plus
Flat or Lugged
6-tile stack (4 over 2)
7:12
Flat or Lugged
10-tile stack
6:12
Polystick XFR
Flat or Lugged
Prohibited without battens
Prohibited without battens
Evaluation Report P12060.02.09-1127
NEMO ETC, U.C. FL52SS-R3I
Cerbflwte OfAuthonzadon #32455 7" EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27. 09/30/2020
Polyglass Roof Underlayments Page 15 of 17
0.
NENlO'l etc.
6.1 Polyglass Roof Underlayments shall be installed in accordance with Polyglass published installation instructions subject to the
limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust
and debris prior to application, and prime the substrate (if applicable).
63
N atl-Base. ,
6.3.1 Non -Tile Applications:
Shall be installed in compliance with requirements for an approved mechanically attached underlayment (ASTM D226, Type
II) in FBC Table 1507.2.1.3. or FBC Residential Table R905.1.1.1 for the type of prepared roof covering to be installed, and the
manufacturer's installation instructions. FBC requirements take precedence over the manufacturer's installation instructions.
Elastobase, Elastobase P or Mule -Hide Nail Base may be covered with a layer of Polystick IR-Xe, Polystick MTS Plus, Polystick
MU-X, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick XFR, Polyflex SAP, Polyflex SA P FR, Mule -Hide SA-APP Cap
Sheet or SA APP Cap Sheet (FR), self -adhered, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt or Polyflex G or Polyflex G
FR, torch applied. Roof cover limitations are those are those associated with the top -layer underlayment, as set forth in Table
1.
6.3.2 Tile Applications:
6.3.2.1 Elastobase (poly -film top), Elastobase P (poly -film top) and Mule -Hide Nail Base are limited to use as a mechanically attached
base sheet' in the "TWO-PLY SYSTEM" from FRSA/TRI Florida High Wind Concrete and Clay Roof -Tile Installation Manual, Sixth
Edition, followed by Polystick MTS Plus, PolystickTU Max, Polystick TU P, Polystick TU Plus, Polystick XFR, Polyflex SAP, Polyflex
SA P FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (1711), self -adhered or Polyflex G or Polyflex G FR, torch -applied. 'file
roof installation method is limited by the selected Cap Sheet, as set forth in Table 1. Refer to Section 5.8.3.2 herein for
attachment requirements.
6.3.2.2 Elastobase (sanded top) and Elastobase P (sanded-top)e are limited to use as a mechanically attached base sheet in the "TWO-
PLY SYSTEM" from FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, followed by
Elastoflex S6 G, Elastoflex S5 G FR or an FBC Approved Mineral Surfaced Cap Sheet (ASTM D6380), asphalt -applied or Polyflex
G or Polyflex 6 FR, torch -applied. Tile roof installation method is limited by the selected Cap Sheet, as set forth in Table 1.
When Elastobase (sanded -top) or Elastobase P (sanded -top) is followed by asphalt -applied Elastoflex S6 G, Elastoflex S6
G FR or FBC Approved Mineral Surfaced Cap Sheet (ASTM D6380), refer to FRSA/TRI, Sixth Edition, Appendix A, Table 1
or Section 5.8.3.2 herein for attachment requirements.
• When Elastobase (sanded top) or Elastobase P (sanded -top) is followed bytorch-applied Polyflex G or Polynex G FR, refer
to Section 5.8.3.2 herein for attachment requirements.
FjydraGuard*MOS APO' 'Mydraipuaro<ine:rtF,%,
l?oLytex SA Q FR, Pciys#ickrlR fie, powasfick i(ATS Plus; polystii
,.
S.
6.4.1 General -
All seal4ap seams (selvage laps) must be firmly rolled with a
in accordance. with Polyglass requirements to ensure full
contact and adhesion. For HydraGuard Dual Pro and
HydraGuard Tile Pro, align the edge of the top sheet to the
end of the glue pattern (the sheet will overlap the fabric).
lysticic TU Plus
View of ovelap Seam of HydraGuard Dual Pro and HydraGuard Tile Pro
Evaluation Report P12060.02.09-1127
NEMO ETC, LLC. FL525"31
certificate ofAuthorizatton #32455 7T" EDrMON (2020) FBC NON-HVHZ EVALUATION Revision 27: 09/30/2020
Polyglass Roof Underiayments Page 16 of 17
OMEMO I etc..
6.4.2 Non-rileADalications:
Shall be installed in compliance with requirements for an approved self -adhering underlayment (ASTM D1970) in FBC
1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering to be installed,
and the manufacturer's installation instructions.
When installed over a mechanically attached base sheet of FBC Approved ASTM D226, Type 11 felt, Elastobase, Elastobase P or
Mule -Hide Nail Base, the base sheet shall be fastened in accordance with FBC 1507.1.1 or R905.1.1.
6.4.3 Tile Applications (excludes HvdraGuard Dual Pro, Polystick IR Xe and Polystick MU X):
Shall be installed in compliance with the requirements for Self -Adhered Membrane set forth in FRSA/TRI Florida High Wind
Concrete and Clay Roof Tile Installation Manual, Sixth Edition and the manufacturer's installation instructions.
Refer to Section 5.8.3 herein for attachment limitations.
Refer to Table 4 herein for tile staging limitations.
6.4.4 Multi -Ply Underlayment Systems:
Polystick MTS Plus or PolystickXFR followed by HydraGuard.Tile Pro, Polyflex SA P, Polystick MTS Plus, Polystick MU X, Polystick
TU Max, Polystick TU P, Polystick TU Plus or Polystick XFR is allowable for use under mechanically attached prepared roof
systems. Limits of use are those associated with the top -layer material. This is not a requirement, but is allowable if a 2-ply
underlayment system is desired.
Polystick MTS Plus followed by HydraGuard Tile Pro, Polyflex SA P, Polystick TU Max, Polystick TLI P or Polystick TU Plus is
allowable for use under adhesive -set tile systems. Limits of use are those associated with the top -layer material. This is not a
requirement, but is allowable if a 2-ply underlayment system is desired.
la flex.$6;G: FRb
ex r E stQ
ofl
6.5
' Elast : G
6.5.1 Shall be installed in compliance with requirements as an alternate to the "Hot Asphalt Applied Cap Sheet" in the 'Iwo Ply
System" in the FRSA/TRl Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, and the
manufacturer's installation instructions.
Refer to Section 5.8.2 and 5.8.3 herein for attachment limitations.
Refer to Table 4 herein for the staging limitations.
,6 ex6.or::P.
6.6.1 Shall be installed in compliance with requirements as analternateto the "Heat Applied Cap Sheet" in the "Two Ply System" in
the FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, and the manufacturer's
installation instructions.
Refer to Section 5.8.3 herein for attachment limitations.
Refer to Table 4 herein for the staging limitations. -
As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this product.
Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule 61620-3 QA requirements. Refer to Section
4 herein for products and production locations having met codified material standards.
UL LLC— QUA9625; (414) 248-6409; Karen.buchmann@ul.com
- END OF EVALUATION REPORT -
Evaluation Report P12060.02.09-RZ7
NEMO ETC, LLC. FL5259-R31
Certificate ofAuthorkadon #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 09/30/2020
Polyglass Roof Underlayments Page 17 of 17