Loading...
HomeMy WebLinkAboutEnergy Efficiency CodeFORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: ELLIS RESIDENCE Street: 7602 OCALA AVENUE Builder Name: City, State, Zip: FORT PIERCE, FL, 34951 Permit Office: ST LUCIE COUNTY Owner: DAVID AND CAROL ELLIS Permit Number: Design Location: FL, Fort Pierce Jurisdiction: ST LUCIE COUNTY County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall T 1552.0 s ft. �� q ) 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior Insulation Area 3. Number of units, if multiple family 1 b . Frame- Wood, Adjacent R=1.00 ftz R=11.11.0 4. Number of Bedrooms 3 c. N/A d. N/A 232232.00 ftz R= ftZ 5. Is this a worst case? No 11. Ceiling Types (1718.0 s ft. q ) R ftz Insulation Area 6. Conditioned floor area above grade (ftz) 1718 a. Roof Deck (Unvented) R=22.0 1718.00 ftz Conditioned floor area below grade (ftz) 0 b. N/A R= ftz 7. Windows(151.0 sqft.) Descriptiori Area c. N/A 12. Ducts R= ftz a. U-Factor: Sgl, U=0.65 151.00 ftz a . Su p: Attic, Ret: Attic, AH: AHU CLST R ftz 6 140 SHGC: SHGC=0.25 b. U-Factor: N/A ftz SHGC: 13. Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ftz a. Central Unit 29.0 SEER:16.00 SHGC: Area Weighted Average Overhang Depth: 6.768 ft. Area Weighted Average SHGC: 14. Heating systems kBtu/hr Efficiency 0.250 8. Skylights a. Electric Strip Heat 27.0 COP:1.00 Area c. U-Factor:(AVG) N/A ftz SHGC(AVG): N/A 15. Hot water systems 9. Floor Types (1718.0 sqft.) Insulation Area a. Electric Cap: 50 gallons a. Slab -On -Grade Edge Insulation R=0.0 1718.00 ftz b. N/A b. Conservation features EF: 0.980 R c. N/A ftZ R= ftz None 16. Credits None Glass/Floor Area: 0.088 Total Proposed Modified Loads: 50.15 Total Baseline Loads: 52.41 PASS I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Ener^CIE 9Y Review of the plans and $T� Code. specifications covered by this calculation indicates compliance PREPARED BY: with the Florida Energy Code. DATE: 9-10-2021 Before construction is completed this building will be inspected for ,.. I hereby certify that this building, as designed, is in compliance with Section 553.908 Florida � compliance with the Florida Energy Code. Statutes. OWNER/AGENT' DATE: DATE: BUILDING OFFICIAL: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402. 1. an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2) n requires 9/9/2021 1:08 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 6 FORM INPUT S WMARY CHECKI- REPORT Title: ELLIS RESIDENCE Building Type: User Owner Name: DAVID AND CAROL ELLIS # of Units: 1 Builder Name: Permit Office: ST LUCIE COUNTY Jurisdiction: ST LUCIE COUNTY Family Type: Detached New/Existing: New (From Plans) Comment: PROJECT Bedrooms: 3 Conditioned Area: 1718 Total Stories: 1 Worst Case: No Rotate Angie: 0 Cross Ventilation: No Whole House Fan: No CLIMATE Address Type: Street Address Lot # Block/Subdivision: PlatBook: Street: 7602 OCALA AVENUE County: St. Lucie City, State, Zip: FORT PIERCE, FL, 34951 Design Location TMY Site Design Temp Int.Design Temp Heating Design Daily Temp 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1718 13744 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfiIID Finished Cooled Heated 1 BEDROOM 2 155 1240 No p 1 2 CLST 2 24 192 No 1 Yes Yes Yes 3 BATH 2 72 576 0 No 1 Yes Yes Yes 4 CLST 3 24 192 0 No 1 Yes Yes Yes 5 BEDROOM 3 144 1152 0 No 1 Yes Yes Yes 6 KITCHEN 156 1248 0 Yes 1 1 Yes Yes Yes 7 GREAT RM 340 2720 0 No 1 Yes Yes Yes 8 FOYER/ DINING 260 2080 0 No 1 Yes Yes Yes 9 MASTER BEDROO 221 1768 0 No 1 Yes Yes Yes 10 M WIC 60 480 0 No 1 1 Yes Yes Yes 11 M BATH 110 880 0 No 1 Yes Yes Yes 12 LAUNDRY 98 784 0 No 1 Yes Yes Yes 13 HALL 42 336 0 No 1 Yes Yes Yes 14 AHU CLST 12 96 0 No 0 1 No Yes Yes 1 No Yes Yes FLOORS # Floor Type 1 Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet _ Slab -On -Grade Edge Insulation BEDROOM 2 25 ft 155 ftz ---- 1 0 0 _ 2 Slab -On -Grade Edge Insulation CLST 2 14 ft 24 ftz --- 1 0 0 _ 3 Slab -On -Grade Edge Insulation BATH 2 6 ft 72 ftz ---- 1 0 0 _ 4 Slab -On -Grade Edge Insulation CLST 3 2 ft 24 ftz ---- 1 0 0 9/9/2021 1:08 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 6 rvrtivl 111'r+U0-LULU INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 5 Slab -On -Grade Edge Insulation BEDROOM 3 12 ft 144 ft2 ---- 1 0 0 6 Slab -On -Grade Edge Insulation KITCHEN 25 ft 156 ft2 ---- 1 0 0 7 Slab -On -Grade Edge Insulation GREAT RM 14 ft 340 ft2 ---- 1 0 0 8 Slab -On -Grade Edge Insulation FOYER/ DINING 20 ft 260 ft2 --- 1 0 0 9 Slab -On -Grade Edge Insulation MASTER BEDRO 13 ft 221 ft2 ---- 1 0 0 10SIab-On-Grade Edge Insulation M WIC 16 ft 60 ft2 ---- 1 0 0 11Slab-On-Grade Edge Insulation M BATH lift 110 ft2 ---- 1 0 0 12SIab-On-Grade Edge Insulation LAUNDRY 7 ft 98 ft2 ---- 1 0 0 13SIab-On-Grade Edge Insulation HALL 1 ft 42 ft2 --- 1 0 0 14SIab-On-Grade Edge Insulation AHU CLST 1 ft 12 ft2 --- 1 0 0 ROOF Roof Gable Roof # Type Materials Area Area Rad Solar SA Emitt Emitt Deck Pitch Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 1861 ft2 0 ft2 Medium N 0.3 No 0.9 No 22 22.62 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 1718 ft2 N N CEILING # Ceiling Type Space R Value Ins Type Area Framing Frac Truss T} 1 Under Attic (Unvented) BEDROOM 2 0 Blown 155 ft2 2 Under Attic (Unvented) CLST 2 0 Blown 0.1 Wood 3 Under Attic (Unvented) BATH 2 0 24 ft2 0.1 Wood 4 Under Attic (Unvented) CLST 3 0 Blown 72 ft2 0.1 Wood 5 Under Attic (Unvented) BEDROOM 3 0 Blown 24 ft2 0.1 Wood 6 Under Attic (Unvented) KITCHEN 0 Blown 144 ft2 0.1 Wed 7 Under Attic (Unvented) GREAT RM 0 Blown 156 ft2 0.1 Wood 8 Under Attic (Unvented) FOYER/ DINING 0 Blown 340 ft2 0.1 Wood 9 Under Attic (Unvented) MASTER BEDRO 0 Blown 260 ft2 0.1 Wood 10 Under Attic (Unvented) M WIC 0 Blown 221 ft2 0.1 Wood 11 Under Attic (Unvented) M BATH 0 Blown 60 ft2 0.1 Wood 12 Under Attic (Unvented) LAUNDRY 0 Blown 110 ft2 0.1 Wood 13 Under Attic (Unvented) HALL Blown 98 ft2 0.1 Wood 14 Under Attic (Unvented) AHU CLST 0 0 Blown 42 ft2 0.1 Wood Blown 12 ft2 0.1 Wood 9/9/2021 1:08 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 6 FORM R405-2020 INPUT SUMMARY CHECKI WALLS Qmt Space Cavity Width Height Sheathing Framing Solar Below 1 N Exterior Concrete Block - Int InsuBEDROOM 2 4.1 13 0 8 0 2 E Exterior Concrete Block - Int InsuBEDROOM 2 4.1 12 104.0 ft2 0 0 0.3 0 3 N Exterior Concrete Block - Int Insul CLST 2 4.1 2 0 8 0 96.0 ft2 p 0 0.3 0 - 4 W Exterior Concrete Block - Int Insul CLST 2 4.1 12 0 0 8 0 16.0 ft2 0 0 0.3 0 5 W Exterior Concrete Block - Int Insul BATH 2 4.1 6 8 0 96.0 ft2 p 0 0.3 0 6 W Exterior Concrete Block - Int Insul CLST 3 4.1 2 0 8 0 48.0 ft2 p 0 0.3 p 7 W Exterior Concrete Block - Int InsuBEDROOM 3 4.1 12 0 8 0 16.0 ft2 p 0 0.3 0 8 S Exterior Concrete Block - Int Insul KITCHEN 4.1 0 8 0 96.0 ft2 p 0 0.3 p 9 W 12 Exterior Concrete Block - Int Insul KITCHEN 4.1 13 0 8 0 96.0 ft2 0 0 0.3 p 10 N Exterior Concrete Block - Int InsulGREAT RM 4.1 14 0 8 0 104.0 ft2 0 0 0.3 0 11 S Exterior Concrete Block - Int InsuFOYER/ DINI 4.1 20 0 8 0 112.0 ft2 0 0 0.3 p 12 E Garage Frame - Wood FOYER/ DINI 11 9 0 8 0 160.0 ft2 0 0 0.3 0 13 N Exterior Concrete Block - Int InsuMASTER BE 4.1 0 8 0 72.0 ft2 0 0.1 0.3 0 14 N 13 Exterior Concrete Block- Int Insul M WIC 4.1 10 0 8 0 104.0 ft2 0 0 0.3 0 15 E Exterior Concrete Block - Int Insul M WIC 4.1 6 0 8 0 80.0 ft2 0 0 0.3 0 16 E Exterior Concrete Block- Int Insul M BATH 4.1 11 0 8 0 48.0 ft2 0 0 0.3 0 - 17 E Exterior Concrete Block - Int Insul LAUNDRY 4.1 0 8 0 88.0 ft2 0 0 0.3 0 18 S 7 Garage Frame - Wood LAUNDRY 11 14 0 8 0 56.0 ft2 0 0 0.3 0 19 S Garage Frame - Wood HALL 11 0 8 0 112.0 ft2 0 0.1 0.3 0 6 0 8 0 48.0 ft2 0 0.1 0.3 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Ft In Ft In Area 1 S HALL None .23 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. / Wall �/ # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Overhang Depth Separation Int Shade 1 N 1 Metal Low-E Single Yes 0.65 0.25 Y 15.0 ft2 2 ft 0 in 1 ft 4 in None Screening 2 W 5 Metal Low-E Single Yes 0.65 0.25 Y 6.0 ft2 2 ft 0 in 1 ft 4 in None None 3 W 7 Metal Low-E Single Yes 0.65 0.25 Y 15.0 ft2 2 ft 0 in 1 ft 4 in None None 4 S 8 Metal Low-E Single Yes 0.65 0.25 Y 9.0 ft2 2 ft 0 in 1 ft 4 in None None 5 N 10 Metal Low-E Single Y� 9 0.65 0.25 Y 20.0 ft2 14 ft 0 in 1 ft 4 in None None 6 N 10 Metal Low-E Single Yes 0.65 0.25 Y 20.0 ft2 14 ft 0 in 1 ft 4 in None None 7 S 11 Metal Low-E Single Yes 0.65 0.25 Y 20.0 ft2 8 ft 0 in 1 ft 4 in None None 8 S 11 Metal Low-E Single Yes 0.65 0.25 Y 20.0 ft2 8 ft 0 in 1 ft 4 in None None 9 N 13 Metal Low-E Single Yes 0.65 0.25 Y 20.0 ft2 2 ft 0 in 1 ft 4 in None None 10 E 16 Metal Low-E Single Yes 0.65 0.25 Y 6.0 ft2 2 ft 0 in 1 ft 4 in None None None 9/9/2021 1:08 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 6 FORM R405-2n9n IAIDI IT cl Innnnnnv nucr.v. .r%• --.,.--- ■•.■.�■� ■ v■.Vvr%VIV 1 RGrVI[ 1 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 500 ftz 500 ftz 29 ft 8 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse ProposedACH(50) .000254 1145.3 62.84 117.97 .0902 5 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COPA 27 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Single SEER: 16 29 kBtu/hr 870 cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.98 50 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cart # Company Name I Collector Storage System Model # Collector Model # Area Volume FEF None None ftz DUCTS / # --- Supply---- Location R-Value Area --- Return ---- Air CFM 25 CFM25 HVAC # Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 140 ftz Attic 14 ftz Default Leakage AHU CLST (Default) c(Default) c 1 1 9/9/2021 1:08 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 6 FORM R405-2020 IIUDI IT QI lnnnnnnV ^Llt ^vi i^-r mr-m •■■•■-1%1 IRGrVI[1 TEMPERATURES Programable Thermostat: N Ceiling Fans: Cooling Jan Heating Jan Venting Jan Feb Feb Feb Mar Mar X Mar Apr Apr Apr May May May Jun Jun Jun Jul Jul Jul Aug Aug Aug Sep Sep Sep Oct Oct Oct X Nov Nov Nov Dec Dec Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM PM 78 80 78 80 78 80 78 80 78 78 78 78 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (WEH) AM PM 78 80 78 80 78 80 78 80 78 78 78 78 80 80 80 80 78 78 78 78 78 78 78 78 Heating(WD) AM PM 65 68 65 68 65 68 65 68 65 65 65 68 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM PM 65 68 65 68 65 68 65 68 65 65 65 68 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 BEDROOM 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 CLST 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH 2 Default(8 Ibs/sq.ft. ft2 ft . 0.3 CLST 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 KITCHEN Default(8 Ibs/sq.ft. ft2 ft 0.3 GREAT RM Default(8 Ibs/sq.ft. ft2 ft 0.3 FOYER/ DINING Default(8 Ibs/sq.ft. ft2 ft 0.3 MASTER BEDR00 Default(8lbs/sq.ft. ft2 ft 0.3 M WIC Default(8 Ibs/sq.ft. ft2 ft 0.3 M BATH Default(8 Ibs/sq.ft. ft2 ft 0.3 LAUNDRY Default(8 lbs/sq.ft. ft2 ft 0.3 HALL Default(8 Ibs/s .ft. ft2 ft 0.3 AHU CLST 9/9/2021 1:08 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 6 of 6