HomeMy WebLinkAboutEPL Display CardFORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE :INDEX* = 100 RECEIVED
�The lowerthe EnergyPerformance Index, the more efficient the home. OCT 0 8 2020
7503 Sebastian Road,Ft. Pierce,FL, St, Lucie Gaurnty
Permitting
1. New construction or existing
2. Single family:or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area above grade (ft2)
Conditioned floor area below grade (ft2)
7. Windows.** Description
a. U-Factor: Dbl, U=0.66
SHGC: SHGC=0.25
b. U-Factor: N/A
SHGC:
c. U-Factor: N/A
SHGC:
Area -Weighted Average Overhang Depth:
Area Weighted Average SHGC:
8. Skylights Description .
U=Factor:(AVG) N/A
SHGC(AVG): N/A
New (From Plans)
10. Wa.11 t pes(1.320.0 sgft.)
Insulation
Area
Detached
a: Concrete Block - Int Insul, Exterior
R=4.1
1092.00 ft2
b: Concrete'Block - Int Insul, AdjacenR=4.1
228.00 ft2
1
c. N/A
R=
ft2
3
d. N/A
R=
ft2
11. Ceiling Types(1337.0 sqft.)
Insulation
Area
.No
a. Under.Attic (Vented)
R=30.0
1337.00 ftZ
1335
b. N/A
R=
ft2
0
c. N/A
R=
ft2
Area
12.. Ducts, location & insulation level
R ft2
85.94 ft2
a. a. Sup: Attic, Ret: Attic, AH: Attic
'
6 267
b.
ft2
C.
13. Cooling Systems
kBtu/hr
Efficiency
ft2
a. Central Unit
27.6 SEER:1.6.00
9. Floor Types Insulation
a. Slab -On -Grade Edge Insulation R= 0.0
b. N/A R=
c. N/A R=
1.500 ft
0.250
Area
N/A ft2
14. Heating Systems - kBtu/hr. Efficiency
a. Electric Strip Heat 27.3 COP:1.00
15. Hot Water Systems
Area a. Electric Cap: 40 gallons
1334.80 ft2 EF: 0.950
ft2
b. Conservation features
ft2
16. Credits
certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above: energy saving features which will. be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features..
K Builder Signature: ate:
�. Address of New Home: 7503 Sebastian Road City/FL Zip: Ft. Pier ce,FL,
*Note: This is not a.Building Energy Rating. If your Index is below 70, your home may qualify for
energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the
Florida Building Code, Energy Conservation,: contact the Florida Building Commission's support staff.. .
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
None
CF, CV
612/2021 4:33:07 PM EnergyGauge® USA 1.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1