HomeMy WebLinkAboutEnergy Efficiency Codek
FORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE. FOR:BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential PegE&%e Method
Project Name: 7503 Sebastian Energygauge
Builder Name: Habitat for HumadiRT '0 8 2020
Street: 7503 Sebastian Road
Permit Office:
City, State, Zip: Ft. Pierce, FL,
Permit Number:-
St. Lucie County
Owner:
Jurisdiction:
Permitting
Design Location: FL, Fort Pierce
County: St. Lucie(Florida Climate Zone 2)
1. New construction or.existing New (From Plans)
10, Wall.Types(1320.0. sgft.)
Insulation Area
2. Single family multiple:family Detached
a.. Concrete Block - Int Insul, Exterior R=4.1 1092.00 ft2
-or .
b. Concrete Block - Int Insul, AdjacenR=4.1 228.00 if
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 3
d. N/A
R=' ft2
5. Is this a worst case? No
11. Ceiling Types(1337.0 sgft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1337.00 ft2
6. Conditioned floor area above rade ft2 1335
g ( )
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
7. Windows(85.9 sgft.)- Description Area
12. Ducts, location & insulation level R ft2
a. U-Factor: Dbl, U=0.66 85.94 ft2
a. a. Sup: Attic, Ret: Aftic,.AH:
Attic. 6 267
SHGC: SHGC=0.25
b.
b. U-Factor: N/A ft2
C.
SHGC:
13. Cooling Systems
kBtu/hr Efficiency
c. U-Factor: N/A ft2
a: Central Unit
27.6 SEER:16.00
SHGC:
Area Weighted Average Overhang Depth: 1.500 ft
Area Weighted Average SHGC: 0.250
14. Heating. Systems
kBtu/hr Efficiency
8. Skylights Description Area
a. Electric Strip Heat
27.3 COP:1.00
U-Factor:(AVG) N/A N/A ft
SHGC(AVG): N/A
15. Hot Water Systems
9. Floor T
Types Insulation Area
YP
a. Electric
Cap: 40 gallons
a. Slab -On -Grade Edge Insulation R= 0.0 1334.80 ft2
EF: 0.950
b. N/A R= ft2'
b. Conservation features
c. N/A R= ... ft2
None
16. Credits
CF, CV
Glass/Floor Area: 0.064 Total Proposed Modified'Loads: 42.34
c
PASS
Total Baseline
Loads: 42.35
I hereby certify that the plans and specifications covered by
Review of the plans and
EKE ST
this calculation are in compliance with the Florida Energy
specifications covered by this .
pF
Code.
calculation indicates compliance
/JGG�
with the Florida Energy Code.����,,;_,;;,,,
PREPARED BY: /-
Before construction is completed
„:--
this building will be inspected for
0% R. a
DATE: June 2, 021
compliance with Section�553.908 -
e�I �
Florida Statutes.
* �
hereby certify that this building, as designed, is in compliance
G,pD WV
with the Florida Ennew C e
OWNER/AGENT:
BUILDING OFFICIAL:
DATE: L O l i--1
DATE:
- Compliance requires certification by the air handler unit manufacturer tnat the air nanaier enciosure quaunes as
certified factory -sealed in accordance with R403.3.2.1: .
- Compliance with a proposed duct leakage Qn.requires a PERFORMANCE Duct.Leakage Test Report.confirming duct
leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0:000 Qn for whole house.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project
requires a PERFORMANCE envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
6/2/2021 4:32:34 PM EnergyGauge® USA 7.0:00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: 7503 Sebastian Energygauge
Address type:
Street Address
Building Type: User
Bedrooms: 3
Lot #:
--
Owner:
Conditioned Area: 1335
Block/SubDivision: -
Total Stories: 1
PlatBook:
--
Builder Name: Habitat for Humanity
Worst Case: No
Street:
7503 Sebastian Road
Permit Office:
Rotate Angle: 0
County:
St. Lucie
Jurisdiction:
Cross Ventilation: Yes
City, State, Zip:
Ft. Pierce,
Family Type: Detached
i
Whole House Fan: No
FL,
New/Existing: New (From Plans)
Terrain: Suburban
Year Construct:
Shielding: Suburban
Comment:
CLIMATE
Design
Design Temp
Int Design Temp
Heating
Design
Daily temp
Location
Tmy Site
97.5% 2.5%
Winter Summer Degree Days
Moisture
Range
FL, Fort Pierce FL VERO-BEACH-MUNICIPA 39 90
70 75
299
62
Low
BLOCKS
Number Name
Area
Volume
1 Entire House
1335
10680
SPACES
Number Name
Area
Volume Kitchen Occupants
Bedrooms
Finished
Cooled
Heated
1 Bed 2
197
1576 No 1
1
Yes
Yes
Yes
_
clst 2
21
168 No 0
Yes
Yes
Yes
-2
Bath 2
117
936 No 0
Yes
Yes
Yes
-3
4 Bed 3
191
1528 No 1
1
Yes
Yes
Yes
_
5 clst 3
18
144 No 0
Yes
Yes
Yes
_
6 Kit Din LR
497
3976 Yes 0
Yes
Yes
Yes
7 pnty
21
168 No 0
Yes
Yes
Yes
_
8 Bed
175
1400 No 2
1
Yes
Yes
Yes
_
9 clst 1
18
144 No 0
Yes
Yes
Yes
_
10 Bath 1
80
640 No 0
Yes
Yes
Yes
FLOORS
(Total Exposed Area = 1335 sq.ft.)
# Floor Type
Space
Exposed Perim Perimeter R-Value Area U-Factor Joist R-Value
Tile Wood Carpet
1 Slab -On -Grade Edge Ins
Bed 2
33
196.5 ft 0.710
-
1.00
0.00 0.00
_
Slab -On -Grade Edge Ins
clst 2
3
21 ft 0.710
-
1.00
0.00 0.00
-2
Slab -On -Grade Edge Ins
Bath 2
9
117 ft 0.710
-
1.00
0.00 0.00
-3
4 Slab -On -Grade Edge Ins
Bed 3
26.5
190.5 ft 0.710
-
1.00
0.00 0.00
_
5 Slab -On -Grade Edge Ins
clst 3
2.5
17.5 ft 0.710
-
1.00
0.00 0.00
_
6 Slab -On -Grade Edge Ins
Kit Din LR
42
497 ft 0.710
-
1.00
0.00 0.00
_
7 Slab -On -Grade Edge Ins
pnty
2.5
21.3 ft 0.710
-
1.00
0.00 0.00
_
8 Slab -On -Grade Edge Ins
Bed 1
26.5
175 ft 0.710
-
1.00
0.00 0.00
_
9 Slab -On -Grade Edge Ins
clst 1
2.5
17.5 ft 0.710
-
1.00
0.00 0.00
_
10 Slab -On -Grade Edge Ins
Bath 1
17.5
81.5 ft 0.710
-
1.00
0.00 0.00
6/2/2021 4:32:34 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2
FORM R405-2020 'INPUT SUMMARY CHECKLIST REPORT
ROOF
✓#
Roof Gable
Area
Roof
Color
Rad Solar
Barr Absor.
SA Emitt Emitt
Tested Tested
Deck Pitch
Insul. (deg)
Type
Materials
Area
1 Gable or Shed
Composition shingles 1407 ft2 222 ft'
Medium
N 0.9
No 0.9 No
0 18.43
ATTIC
# Type
Ventilation
Vent Ratio (1 in) Area RBS IRCC
1 Full attic
Vented
300
1335 ft' N
N
CEILING
(Total Exposed Area = 1337 sq.ft.)
# Ceiling Type
Space
R-Value
Ins. Type
Area U-Factor Framing Frac.
Truss Type
1 Under Attic(Vented)
Bed 2
30.0
Blown
197.0ft2
0.053 0.10
Wood
_
Under Attic(Vented)
clst 2
30.0
Blown
21.0ft2
0.053 0.10
Wood
-2
3 Under Attic(Vented)
Bath 2
30.0
Blown
117.0ft2
0.053 0.10
Wood
_
4 Under Attic(Vented)
Bed 3
30.0
Blown
191.0ft2
0.053 0.10
Wood
_
5 Under Attic(Vented)
clst 3
30.0
Blown
18.0ft2
0.053 0.10
Wood
_
6 Under Attic(Vented)
Kit Din LR
30.0
Blown
497.0ft2
0.053 0.10
Wood
_
7 Under Attic(Vented)
pnty
30.0
Blown
21.0ft'
0.053 0.10
Wood
_
8 Under Attic(Vented)
Bed 1
30.0
Blown
175.0ft2
0.053 0.10
Wood
_
9 Under Attic(Vented)
clst 1
30.0
Blown
18.0ft2
0.053 0.10
Wood
_
10 Under Attic(Vented)
Bath 1
30.0
Blown
82.0ft2
0.053 0.10
Wood
WALLS
(Total Exposed Area = 1320 sq.ft.)
Adjacent
Cavity
Width
Height
Area U- Sheath Frm.
Solar Below
�# Omt To
Wall Type
Space
R-Value
Ft In
Ft In
sq.ft. Factor R-Value Frac. Absor. Grade
1 N Exterior
Conc. Blk - Int Ins
Bed 2
4.1
13.0 6
8.0 0
108.0 0.149 0 0
0.40 0 %
_
2 E Exterior
Conc. Blk - Int Ins
Bed 2
4.1
13.0 6
8.0 0
108.0 0.149 0 0
0.40 0 %
_
3 W Exterior
Conc. Blk - Int Ins
Bed 2
4.1
6.0 0
8.0 0
48.0 0.149 0 0
0.40 0 %
_
4 E Exterior
Conc. Blk - Int Ins
clst 2
4.1
3.0 0
8.0 0
24.0 0.149 • 0 0
0.40 0 %
_
5 E Exterior
Conc. Blk - Int Ins
Bath 2
4.1
9.0 0
8.0 0
72.0 0.149 0 0
0.40 0 %
_
6 E Exterior
Conc. Blk - Int Ins
Bed 3
4.1
13.0 6
8.0 0
108.0 0.149 0 0
0.40 0 %
_
7 S Exterior
Conc. Blk - Int Ins
Bed 3
4.1
13.0 0
8.0 0
104.0 0.149 0 0
0.40 0 %
_
8 E Exterior
Conc. Blk - Int Ins
clst 3
4.1
2.0 6
8.0 0
20.0 0.149 0 0
0.40 0 %
_
9 S Exterior
Conc. Blk - Int Ins
Kit Din LR
4.1
13.0 6
8.0 0
108.0 0.149 0 0
0.40 0 %
_
10 N Exterior .
Conc. Blk - Int Ins
Kit Din LR
4.1
14.0 .0
8.0 0
112.0 0.149 0 0
0.40 0 %
_
11 W Garage
Conc. Blk - Int Ins
Kit Din LR
4.1
14.0 6
8.0 0
116.0 0.149 0 0
0.40 0 %
_
12 S Exterior
Conc. Blk - Int Ins
pnty
4.1
2.0 6
8.0 0
20.0 0.149 0 0
0.40 0 %
_
13 W Exterior
Conc. Blk - Int Ins
Bed 1
4.1
12.0 6
8.0 0
100.0 0.149 0 0
0.40 0 %
_
14 N Garage
Conc. Blk - Int Ins
Bed 1
4.1
14.0 0
8.0 0
112.0 0.149 0 0
0.40 0 %
_
15 W Exterior
Conc. Blk - Int Ins
clst 1
4.1
2.0 6
8.0 0
20.0 0,149 0 0
0.40 0 %
_
16 S Exterior
Conc. Blk - Int Ins
Bath 1
4.1
11.0 16
8.0 0
92.0 0.149 0 0
0.40 0 %
_
17 W Exterior
Conc. Blk - Int Ins
Bath 1
4.1
6.0 0
8.0 0
48.0 0.149 0 0
0.40 0 %
DOORS
(Total Exposed Area = 42 sq.ft.)
Width Height
V # Omt Adjacent To Door Type
Space
Storms
U-Value
Ft In Ft In
Area
N Exterior
Wood
Kit Din LR
None
0.39
3.00 0 7.00 0
21.0ft'
-1
2 N Exterior
Wood
Kit Din LR
None
0.39
3.00 , 0 7.00 0
21.0ft2
6/2/2021 4:32:34 PM EnergyGauge® USA 7.0.00,- FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
WINDOWS
(Total Exposed Area = 86 sq.ft.)
Wall
-Overhang--
V# Ornt ID Frame Panes
NFRC U-Factor SHGC Imp Storm Area
Depth Separation
Interior Shade Screening
1 N
1 None Double (Clear)
Yes 0.66
0.25 Y N 18.7ft2
1.0 ft 6 in 1.0 ft 0 in
Drapes/blinds Exterior 50%
_
S
7 None Double (Clear)
Yes 0.66
0.25 Y N 16.9ft2
1.0 ft 6 in 1.0 ft 0 in
Drapes/blinds Exterior 50%
-2
S
9 None Double (Clear)
Yes 0.66
0.25 Y N 24.0ft2
1.0 ft 6 in 1.0 ft 0 in
Drapes/blinds Exterior 50%
-3
4 N
10 None Double (Clear)
Yes 0.66
0.25 Y N 10.Oft2
1.0 ft 6 in 1.0 ft 0 in
Drapes/blinds Exterior 50%
_
5 W 13 None Double (Clear)
Yes 0.66
0.25 Y N 16.4ft2
1.0 ft 6 in 1.0 ft 0 in
Drapes/blinds Exterior 50%
INFILTRATION
# Scope Method
SLA
CFM50 ELA EgLA
ACH ACH50
Space(s)
1
Wholehouse Proposed ACH(50)
0.00036
1246 68.36 128.34
0.1263 7.0
All
GARAGE
#
Floor Area
Roof Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
383 ft2
383 ft2
64 ft
8 ft
1
MASS
#
Mass Type
Area
Thickness Furniture Fraction
Space
1
Default(8 Ibs/sq.ft.)
0 ft2
O ft
0.30
Bed 2
Default(8 Ibs/sq.ft.)
0 ft2
O ft
0.30
cast 2
-2
Default(8 Ibs/sq.ft.)
0 ft2
O ft
0.30
Bath 2
-3
4
Default(8 Ibs/sq.ft.)
0 ft2
O ft
0.30
Bed 3
_
5
Default(8 Ibs/sq.ft.)
0 ft2
O ft
0.30
clst 3
Default(8 Ibs/sq.ft.)
0 ft2
0 ft
0.30
Kit Din LR
-6
7
Default(8 Ibs/sq.ft.)
0 ft2
0 ft
0.30
pnty
_
8
Default(8 Ibs/sq.ft.)
0 ft2
O ft
0.30
Bed 1
_
9
Default(8 Ibs/sq.ft.)
0 ft2
O ft
0.30
clst 1
_
10
Default(8 Ibs/sq.ft.)
0 ft2
0 ft
0.30
Bath 1
HEATING SYSTEM
#
System Type
Subtype
AHRI # Efficiency Capacity -Geothermal
HeatPump- Ducts Block
kBtu/hr Entry Power
Volt Current
1
Electric Strip Heat
None
COP: 1.00 27.3 0.00
0.00 0.00 sys#1 1
COOLING SYSTEM
#
System Type
Subtype/Speed
AHRI # Efficiency
Capacity Air Flow SHR Duct Block
kBtu/hr cfm
1
Central Unit
Split/Single
SEER:16.0 27.6 0
0.74 sys#1 1
6/2/2021 4:32:34 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
HOT WATER SYSTEM
# System Type
Subtype
Location
EF(UEF) Cap Use
SetPnt
Fixture Flow Pipe Ins.
Pipe length
1 Electric
None
Garage
0.95 (0.93) 40.00 gal 61 gal
120 deg
Standard None
83
Recirculation
Recirc Control
Loop Branch Pump DWHR
Facilities Equal
DWHR
Other Credits
System
Type
length length power
Connected Flow
Eff
1 No
NA NA NA No
NA
NA
NA
None
DUCTS
Duct -----Supply---
----Retum---
Air'
CFM 25 CFM 25
'
HVAC #
�# Location
R-Value Area Location
R-Value Area Leakage Type
Handler
TOT
OUT QN
RLF Heat Cool
1 Attic
6.0 267 ftz
Attic
6.0 67 ftz Default Leakage
Attic
(Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: N
Ceiling Fans: N
Cooling [ ] Jan
[ ] Feb
[ ] Mar
[ ] Apr
[ ] May [X] Jun [X] Jul
[X] Aug
[X] Sep
[ ] Oct [ ] Nov [ ] Dec
Heating [X] Jan
[X],Feb
[X] Mar
[ ] Apr
[ ] May [ ] Jun [ ] Jul
[ ] Aug •
[ ] Sep
[ ] Oct [X] Nov [X] Dec
Venting [ ] Jan
[I Feb
[X] Mar
[X] Apr
[ ] May [I Jun , [ ]'Jul
[ ] Aug
[ ] Sep
[X] Oct` [X] Nov [ ] Dec
Thermostat Schedule: HERS 2006
Reference
Hours
Schedule Type
1
2
3 4 5 6
7
8 9
10
11 12
Cooling (WD)
AM •
PM
78
80
78
80
78 78 78 78
80 80 78 78
78
78
78,
78
80 80
78 78
80 80
78 78
Cooling (WEH)
AM
PM
78
80
78
80
7.8 78 78 78
80 80 78 78
78
78
78
78
80 80
78 78•
80' 80
78 78
_ Heating (WD)
AM
PM
65
68'
65
68
65 65 65 65
68: 68 68 68
65
68
68
68
68 68
68 68
68 '68
68 68
_ Heating (WEH)
AM
PM
65
68
65
68
65 65 65 65
68 68 68 68
65
68
68
68
68 68
68 68
68 68
68 68
6/2/2021 4:32:34 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5