Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Project Information
V? RECEIVED Load Short FOt't'tl Job: p#1301-002-0131-000-2 o -- wrightsoft OCT 0 8 2020 Date: June 2, 2021 Entire House sy: Josh Pubnan WebREPS, LLC St. Lucie County Plan: 7503 Sebastian Road Permittin-- p.,- 1892 commerce Menue, Vero Beach, FL 32960 Phone:800-810-3280 Fax 888.971-2999 Eniail:sales@webrepshvac.00mV1bb:www.webrepsMolesale.com License: CAC054709 Ir rroject intormation For: Joseph Gianna, Habitat for Humanity Ft Pierce, FL Design Information Htg Clg Infiltration Outside db (°F) 42 90 Method Simplified Inside db (°F)- 70 75 Construction quality Semi -tight Design TD ('F) 28 15 Fireplaces 0 Daily range - L Inside humidity (%) 30 50 . Moisture difference (grAb) 1 56 HEATING EQUIPMENT COOLING EQUIPMENT Make Goodman Make Goodman Mfg. Trade Heat Strip Trade GOODMAN Model Cond GSX160301 F AHRI ref Coil ASPT30C14A AHRI ref 200825240 Efficiency 100 EFF Efficiency 13.0 EER,16 SEER Heating input 8.0 kW Sensible cooling - 20424 Btuh Heating output 27297 Btuh Latent cooling 7176 Btuh Temperature rise 27 OF Total cooling 27600 Btuh Actual airflow 920 cfrn Actual airflow 920 cfrn Airflowfactor 0.054 dim/Btuh Airflowfactor 0.051 cFmBtuh Static pressure 0.60 in H2O- Static pressure 0.60 in H2O Space thermostat Load sensible heat ratio 0.75 ROOM NAME Area M Htg load (Btuh) Clg load (Btuh) Htg AVF (t fm) Clg AVF 0m) Bed 2 197 3515 2405 188 122 clst 2 21 0 0 0 0 Bath 2 117 1103 1357 59 69 Bed 3 191 2897 2295 155 116 dst3 18 0 0 0 0 Kit Din LR 497 5193 8497 278 430 pnty 21 0 .0. 0 0 Bed 175 2653 2797 142 141 clst 1 18 0 0 0 0 on I 011r Rd9 97 43 Dam i Calculations approved byACCA to meet all requirements of Manual J 8th Ed. .� .«,,.. , ! i ghtsoft- 2021-Jun-0216:33:50 Right -Suite® Universal 2021 21.0.07 RSU16998 Page 1 J4C0....abitatfor Humanity PSLV503 Sebastian Road.rup Calc= MJ8 Front Door faces: N , Entire House 1335 17165 18194 920 920 Other equip loads 0 1707 Equip. @ 1.00 RSM 19900 Latent cooling 6707 . n .194c 474CiG 7rrn7 ain 99n :Y1 1 V 1I1L0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. 2021-Jun-0216:33:50 1 wrightSOfC® Pi9ht-Suite® Universal 202121.0.07 RSU16998 Page ACCA...abitatforHumanity PSL\7503Sebastian Road.rup Calc=W8 FrontDoarfaces: N -�- wrightsoft" Project Summary Entire House WebREPS, LLC Job: p#1301-602-0131-000-2 Date: June 2, 2021 By- Josh Putrnan Plan: 7503 Sebastian Road 1892 Commerce Avenue, Vero Beach, FL 32960 Phone: 800-810-3280 Fax 888-971-2999 Email: sales@webrepamc.cem V%bb: www.webrepswholesale.00m License: CAGO54709 t� Project Information For. Joseph Gianna, Habitatfor Humanity Ft. Pierce, FL Notes: 7503 Sebastian Road Ft Pierce Florida p#1301-602-0131-000-2 Design Information Weather. St Lucie County Infl, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 56 grAb Heating Summary Sensible Cooling Equipment Load Sizing Structure 13885 Btuh Structure 12772 Btuh Ducts 3280 Btuh Ducts 5421 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 1707 Btuh Piping 0 Btuh Equipment load 17165 Btuh Use manufacturers data Rate/swing multiplier Equipment:sensible load 1.00 19900 Btuh Infiltration Method Simplified Latent Cooling Equipment Load Sizing Construction quality Fireplaces Semi -tight 0 Structure 5291 Btuh Ducts 1416 Btuh Central vent (0 cfrn) 0 Btuh Area (ft� Heatingg Coolingg 1335 1335 (none) Equipment latent load 6707 Btuh Volume (fc� Air changesmour 10678 10678 0.31 0.16 Equipment Total Load (Sen+Lat) 26607 Btuh Equiv. AVF (cfm) 55 28 Req. total capacity at 0.74 SHR 2.2 ton Heating Equipment Summary Cooling Equipment Summary Make Goodman Make Goodman Mfg. Trade Heat Strip Trade GOODMAN Model Cond GSX160301 F AHRI ref Coil ASPT30C14A AHRI ref 200825240 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input Heating output 8.0 kW 27297 Btuh Sensible cooling Latentcooling 20424 7176 Btuh Btuh Temperature rise Actual airflow 27 OF 920 cfm Total cooling Actual airflow 27600 920 Btuh dm Airflowfactor Static pressure 0.054 dmBtuh 0.60 in H2O Airflowfactor Static pressure 0.051 0.60 cfm/Btuh in H2O Space thermostat Load sensible heat ratio 0.75 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. 2021-Jun-0216:33:50 wrightsoft' „_ .. _., Right Suite®Universal 2021 21.0.07 RSU16998 Page 1 ACCk,,,abitatfor Humanity PSL\7503Sebastian Road.rup Calc=MJ8 FrontDoorfaces: N Job #: p#1301-002-0131-000-2 Performed by Josh Putman for. Joseph Gianna R. Pierce, FL Sheet 1 WebREPS, LLC 1892 Commerce Avenue Vero Beach, R-32960 Phone:800-8103280 Fax: 888-971 2999 www.webrepswholesale.com sales@webrepshvac.com Scale:1 : 69 1 Rift &Aq& Uriversal2021 21.0.07RSU16M 2021Jun-MIM.58 _f* PSLV503SebmJmRoaJnp Duct System Summary Job: p#1301-602-0131-000-2 wrightsoft� Date: June2,,2021 Entire House By: Josh Pubran WebREPS, LLC Plan: 7503 Sebastian Road 1892 Commerce Avenue, Vero Beach, FL 32960 Phone:800-810-3280 Fax 888-971-2999 .Email: sales@webrepshvac.com Nkb: www.webrepswholesale.com License: CAC054709 rroject intormation For. Joseph Gianna, Habitat for Humanity Ft. Pierce, FL Extemal static pressure Pressure losses Available static pressure Supply / return available pressure Lowestfiiction rate Actual airflow Total effective length (TEL) Heating 0.60 in H2O 0.24 in H2O 0.36 in H2O 0.226 / 0.134 in H2O 0.084 in/100ft 920 cfm 427 Supply Branch Detail Table Cooling 0.60 in H2O 0.24 in H2O 0.36 in H2O 0.226 / 0.134 in H2O 0.084 in/100ft 920 cfm Name Design (Btuh) Htg (cf-n) Clg 0m) . Design FIR Diam (in) H x W (in) Duct Mat . Actual Ln (ft) Ftg.Egv Ln (ft) Trunk Bath 1 h 1805 97 43 0.093 6.0 Ox 0 VIFx 18.2 225.0 st2 Bath 2 c 1357 59 69 0.089 5.0 OX 0 VIFX 24.6 230.0 st4 Bed 1 h 2653 142 141 0.093 7.0 Ox 0 VIFX 17.1 225.0 st2 Bed 2 h 3515 188 122 0.086 8.0 OX 0 VIFX 32.7 230.0 st4 Bed 3 h 2897 155 116 0.084 7.0 Ox 0 VIFX 32.8 235.0 st4 Kit DinLR C 2124 70 107 0.100 6.0 Ox0 VIFx 20.5 205.0 st3 Kit Din LR-A c 2124- 70 107 0.099 6.0 OX 0 VIFX 18.0 210.0 st3 Kit Din LR B c 2124 70 107 0.096 6.0 Ox 0 VIFx 25.7 210.0 st3 Kit Din LR-C C 2124 70 107 0.101 6.0 Ox 0 VIFX 13.2 210.0 st3 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (d m) (cfm) FIR (fpm) (in) (in) Material- Trunk st1 PeakAVF 920 920 0.084 613 15.0 12 x 18 RectFbg st2 PeakAVF 239 184 0.093 684 8.0 0 x 0 VinlFlx st1 st4 PeakAVF 403 306 0.084 513 12.0 0 x 0 VinlFlx st3 st3 PeakAVF 681 736 0.084 688 14.0 0 x 0 VinlFlx st1 2021-Jun-0216: -1- wrightsoftm age 1 Right-Suite®Universal 2021 21.0.07 RSU16998 Page 1 ACCA ...abitatfor Humanity PSU7503 Sebastian Road.rup Calc= MJ8 FrontDoorfaces: N Return Branch Detail Table Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rb4 Ox 0 920 920 159.2- 0.084 521 18.0 Ox 0 VIFx rt1 Name Trunk Type Htg (cfm) Clg (cfm) Design FR Veloc (fpm) Diam (in) H x W (in) Duct Material Trunk rt1 PeakAVF 920 920 0.084 409 15.0 .. 18 x 18 RectFbg wrightso_ftm 2021-Jun-021633:50 tight -Suite® Universal 2021 21.0.07 RSU16998 Page 2 ACCA...abitatforHumanityPSL17503SebasbanRoad.rup Calc=MJ8 FrontDoorfaces: N