Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Survey
SHEET 1 OF 2 SURVEY SKETCH ------------ SURVEY NOT COMPLETE WITHOUT ALL SHEETS MAP OF BOUNDARY SURVEY PREPARED FOR JM CUSTOM POOLS, INC. MIN. SETBACK REQ. FRCS, IT SIDES FAk CNR SIDES 2 . � 33 i9 G i 2S. A-3'3D c�2y 2.67 A 9l \ 40 n L=117,31' \ R=3819.72' 4r1'45'24' 3.19 �.• ryoP ah 1 ��oFR ¢ o �o ~ o C ®3,41 9 2,a4 4OT �8) R sr Sr .^ r 697 2 %2 2�1 OT�F o 1 FS�oF40 ceS 19� e� F 3 "Op, 0c�F2 (,ry , 4 99 C ' iV6 p Ip' � •, q 0 lZo 4 S 1000 , 1 4a 6 �T e<O �2 g8, <p�,lr 424,2 y��ti 2 9 0 21 f 69�2?'� r1 f 1 f r fff NOTES: ELEVATION NOTES: NORTH ARROW & ALL BEARINGS AND DISTANCES SHOWN ARE RECORD AND MEASURED, UNLESS OTHERWISE SHOWN. ALL ELEVATIONS SHOWN ARE BASED UPON NORTH AMERICAN VERTICAL DATUM OF 1988 (NAVD'88). GRAPHIC SCALE P.U.&D.E. = PUBLIC UTILITY AND DRAINAGE EASEMENT. BEARINGS ARE BASED UPON THE RECORD BEARING FOR THE PROPOSED FINISHED FLOOR ELEVATION IS SUBJECT TO CHANGE PER HEALTH DEPARTMENT. 0' 20' 1 30' SOUTHERLY RIGHT OF WAY LINE OF SOVEREIGN WAY. PERMIT NUMBER AND CONTACT JM CUSTOM POOLS, INC. DUSTING ELEVATION- x ROPOSED ELEVATION- \20.00 DRAINAGE ARROW -�- — 2106-4 REVISION - KNOW I T NOW, INC. PROFESSIONAL 'SURVEYING AND MAPPING 5220 US HIGHWAY 1, #104 • VERO BEACH, FL 32967 PHONE - (888) 396-7770 WWW.KINSURVEYORS.COM • FIELD DATE — O6/19/2021 FIE REVISION — REVISION - REVISION - REVISION - REVISION - REVISION - REVISION - REVISION - REVISION - FLORIDA BUSINESS CERTIFICATE OF AUTHORIZATION NUMBER LB 6912 SHEET 2 OF 2 SURVEY DETAILS ------------ SURVEY NOT COMPLETE WITHOUT ALL SHEETS LEGAL DESCRIPTION: JOB NUMBER: 2106-267 LOT A AND LOT B, LESS THE SOUTH 50 FEET, BLOCK 2, QUEEN'S COVE UNIT 1, ACCORDING TO THE MAP OR FIELD WORK DATE: 06/19/2021 PLAT THEREOF, AS RECORDED IN PLAT BOOK 11, PAGE(S) 128 AND 12C, OF THE PUBLIC RECORDS OF PROPERTY ADDRESS: ST. LUCIE COUNTY, FLORIDA. 51 SOVEREIGN WAY, HUTCHINSON ISLAND, FL 34949 FLOOD INFORMATION: r PANEL NUMBER: 12111 CO089K FIRM DATE: FEBRUARY 19, 2020 FLOOD ZONE: AE - -=,:: ...• ,: - BASE FLOOD ELEVATION: 4.0 COMMUNITY NAME: ST. LUCIE OUNTY COMMUNITY NUMBER: 120285 AERIAL PHOTOGRAPH P , Google Earth SURVEYOR'S LEGEND FFE = FINSHED FLOOR ELEVATION PCC = POINT OF COMPOUND CURVATURE LINETYPES FIP = FOUND IRON PIPE PCP = PERMANENT CONTOL POINT A/C = AIR CONDITIONING FIPC = FOUND IRON PIPE AND CAP POB = POINT OF BEGINNING = BOUNDARY LINE BB = BEARING BASIS FIR = FOUND IRON ROD POC = POINT OF COMMENCEMENT BFP = BACKFLOW PREVENTER FIRC = FOUND IRON ROD AND CAP PP = POOL PUMP = STRUCTURE LINE BLDG = BUILDING FN = FOUND NAIL PRC = POINT OF REVERSE CURVATURE — .. — .. —= CENTERLINE BLK = BLOCK FN&D = FOUND NAIL AND DISC PRM = PERMANENT REFERENCE MONUMENT BM = BENCHMARK FND = FOUND PT = POINT OF TANGENCY — — — — —= EASEMENT LINE C = CURVE FPK = FOUND PK NAIL R = RADIUS -- o o = FENCE LINE CAN = CABLE T.V. RISER FPKD = FOUND PK NAIL AND DISC RNG = RANGE CB = CATCH BASIN FRRSPK = FOUND RAILROAD SPIKE R/W = RIGHT OF WAY --------------= OLD LOT LINE CL = CENTERLINE GAR = GARAGE S = SEPTIC CLF = CHAIN LINK FENCE HYD = FIRE HYDRANT SEC = SECTION SYMBOLS CLP = CONCRETE LIGHT POLE ID = IDENTIFICATION SIR = SET IRON ROD AND CAP CONC = CONCRETE L = LENGTH SPKD = SET PK NAIL AND DISC= FIRE HYDRANT ®= CATCH BASIN CP = CONTROL POINT LB If= LICENSED BUSINESS SV = SEWER VALVE CPP = CONCRETE POWER POLE LS # = LICENSED SURVEYOR TBM = TEMPORARY BENCHMARK ®= WATER METER © =SANITARY MANHOLE D = DEED M = MEARSURED TOB = TOP OF BANK POWER POLE Q = CABLE T.V. SERVICE DF = DRAINFIELD MB = MAP BOOK TWP = TOWNSHIP ELEV = ELEVATION MES = MITERED END SECTION TR = TELEPHONE RISER ©= GAS SERVICE = ELECTRIC SERVICE EM = ELECTRIC METER MH = MANHOLE TYP = TYPICAL EOW = EDGE OF WATER MLP = METAL LIGHT POLE WIT = WITNESS = LIGHT POLE ® = TELEPHONE SERVICE EP = EDGE OF PAVEMENT OHW = OVERHEAD WIRES WLP = WOOD LIGHT POLE F = FIELD P = PLAT WM = WATER METER ® = WELL ® = DRAINAGE MANHOLE FCM = FOUND CONCRETE MONUMENT PB = PLAT BOOK WPP = WOOD POWER POLE FDH = FOUND DRILL HOLE PC = POINT OF CURVATURE WV = WATER VALVE = BENCHMARK Q = SANITARY SERVICE SURVEYOR'S NOTES 1. UNDERGROUND UTILITIES, BUILDING FOUNDATIONS, AND OTHER UNDERGROUND FIXED IMPROVEMENTS WERE NOT LOCATED, UNLESS OTHERWISE INDICATED. TO THE EXTENT THAT THIS TYPE OF INFORMATION IS SHOWN, IT IS SHOWN SOLELY ON THE BASIS OF SURFACE INDICATIONS OBSERVED BY THE SURVEYOR AND MAY NOT BE COMPLETE. 2. JURISDICTIONAL WETLANDS AND ENDANGERED OR THREATENED SPECIES HABITAT, IF ANY, THAT MAY EXIST ON OR AROUND THE SURVEY SITE WERE NOT DETERMINED OR LOCATED. 3. THE SURVEY DATE IS THE FIELD DATE SHOWN IN THE TITLE BLOCK, NOT THE SIGNATURE DATE. 4. THIS SURVEY MAP OR THE COPIES THEREOF ARE NOT VALID WITHOUT THE SIGNATURE AND THE ELECTRONIC OR ORIGINAL RAISED SEAL OF A FLORIDA LICENSED SURVEYOR AND MAPPER. 5. FENCES SHOWN ON SURVEY ARE FOR ILLUSTRATIVE PURPOSES ONLY. FENCE TIES SHOWN ARE RELATIVE TO THE CENTER OF SAID FENCE. THE SURVEYOR WILL NOT BE RESPONSIBLE FOR DAMAGES RESULTING FROM THE REMOVAL AND/OR CHANGES TO ANY FENCES UNLESS THE SURVEY WAS PROVIDED SPECIFICALLY FOR FENCE LOCATION PURPOSES. 6. PROPERTY LINES AND OR IMPROVEMENTS SHOWN WERE PHYSICALLY LOCATED BY FIELD SURVEY. 7. MONUMENTS FOUND OR SET ARE SHOWN, CALCULATED LINES AND INFORMATION IS NOTED BY (C). 8. COMPUTATIONS OF LINES AND OR DATA NOT FOUND ARE SHOWN AS (C). 9. ACCURACIES OBTAINED IN THIS SURVEY IS GREATER THAN (RURAL) 1' IN 5000', (SUBURBAN) 1' IN 7500', (COMMERCIAL) 1' IN 10,000'. 10. PRIOR TO SURVEY INFORMATION OBTAINED WAS LEGAL DESCRIPTION FROM CLIENT OR FROM PUBLICLY PUBLISHED COUNTY TAX COLLECTOR SITE, RECORDED PLATS AND OR SECTION CORNER RECORDS IF APPLICABLE. 11. IF ONLY A DIGITAL SURVEY COPY IS REQUIRED A SURVEY REPORT WILL BE PLACED IN FILE. THE DIGITAL SURVEY IS NOT FULL AND COMPLETE WITHOUT THE SURVEY REPORT FILE. SURVEYORS SIGNATURE CERTIFIED TO: NOT VALID WITHOUT THE SIGNATURE AND ORIGINAL RAISED SEAL OR ELECTRONIC SEAL OF THE FLORIDA THOMAS ROCK LICENSED SURVEYOR BELOW. THE SURVEYOR HEREBY CERTIFIES THAT THE ELECTRONIC SIGNATURE AND PRINCESS ROCK SEAL HEREON MEETS PROCEDURES SET FORTH IN CHAPTER 5J-17.062 OF THE FLORIDA ADMINISTATIVE CODE, PURSUANT TO SECTION 472.025, FLORIDA STATUTES. THE SURVEYOR HEREBY CERTIFIES THAT JM CUSTOM POOLS, INC. THIS SURVEY MEETS THE STANDARDS OF PRACTICE FOR SURVEYS, SET FORTH BY THE FLORIDA BOARD OF SURVEYORS AND MAPPERS IN CHAPTER 5J-17.051 AND 5J-17.052 OF THE FLORIDA ADMINISTRATIVE CODE, PURSUANT TO SECTION 472.027, FLORIDA STATUTES. KNOW IT NOW, INC. PROFESSIONAL SURVEYING AND MAPPING BILL HY T DATE 5220 US HIGHWAY 1, #140 • SURVEYOR AND MAPPER #4636 VERO BEACH, FL 32967 STATE OF FLORIDA PHONE - (888) 396-7770 WWW.KINSURVEYORS.COM ON FLORIDA BUSINESS CERTIFICATE OF AUTHORIZATION NUMBER LB 6912