HomeMy WebLinkAboutGASPARILLA REVISION- ENERGY CALCPROJECT
Title:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction: ST LUCIE COUNTY
ST LUCIE COUNTY
SYNERGY BUILDERS
1
HUDSON 4
Family Type:
New/Existing:
Bedrooms:
Conditioned Area:
Total Stories:
Worst Case:
Rotate Angle:0
No
1
1833
4
New (From Plans)
Detached
Address Type:
Lot #
Block/Subdivision:
PlatBook:
Street:
County:
City, State, Zip:
FL , 34983
PORT ST LUCIE ,
St. Lucie
430 SE GASPARILLA A
Street Address
Comment: GARAGE LEFT
Building Type: User
Cross Ventilation:No
Whole House Fan:No
TMY Site
Design Temp Int Design Temp Heating Design Daily Temp
Design Location 2.5 %97.5 %Degree Days Moisture RangeWinter Summer
CLIMATE
90 70 7536969 Medium45FL_MELBOURNE_REGIOFL, MELBOURNE_REGIO______
Number Name Area Volume
BLOCKS
1 Entire House 1833 17168
Number NameAreaVolume
SPACES
Kitchen Occupants Bedrooms Cooled HeatedInfil ID Finished
1 M BATH 84 672 No 0 Yes Yes1Yes
2M WIC 126 1008 No 0 Yes Yes1Yes
3 MASTER BEDROO 210 1680 No 01 Yes Yes1Yes
4 BEDROOM 3 149 1192 No 01 Yes Yes1Yes
5 CLST 3 16 128 No 0 Yes Yes1No
6 KITCHEN/DINING 376 4512 Yes 0 Yes Yes1Yes
7 BATH 2 72 576 No 0 Yes Yes1Yes
8 BEDROOM 2 144 1152 No 01 Yes Yes1Yes
9 HALL 39 312 No 0 Yes Yes1No
10 CLST 2 16 128 No 0 Yes Yes1No
11 LAUNDRY56448 No 0 Yes Yes1No
12 AHU CLST 9 72 No 0 Yes Yes1No
13 GREAT ROOM 250 3000 No 0 Yes Yes1Yes
14 FOYER 112 896 No 0 Yes Yes1Yes
15 CLST 4 16 128 No 0 Yes Yes1Yes
16 BEDROOM 4/DEN 158 1264 No 01 Yes Yes1Yes
# Floor Type Area Tile Wood Carpet
FLOORS
Perimeter R-Value Joist R-ValueSpace Perimeter
1 84 ft² 100______ Slab-On-Grade Edge Insulation - - - -020 ft M BATH
2 126 ft² 100______ Slab-On-Grade Edge Insulation - - - -09 ft M WIC
1/5/2022 5:13 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
# Floor Type Area Tile Wood Carpet
FLOORS
Perimeter R-Value Joist R-ValueSpace Perimeter
3 210 ft² 100______ Slab-On-Grade Edge Insulation - - - -029 ft MASTER BEDRO
4 149 ft² 100______ Slab-On-Grade Edge Insulation - - - -011 ft BEDROOM 3
5 16 ft² 100______ Slab-On-Grade Edge Insulation - - - -01 ft CLST 3
6 376 ft² 100______ Slab-On-Grade Edge Insulation - - - -026 ft KITCHEN/DININ
7 72 ft² 100______ Slab-On-Grade Edge Insulation - - - -06 ft BATH 2
8 144 ft² 100______ Slab-On-Grade Edge Insulation - - - -012 ft BEDROOM 2
9 39 ft² 100______ Slab-On-Grade Edge Insulation - - - -01 ft HALL
10 16 ft² 100______ Slab-On-Grade Edge Insulation - - - -01 ft CLST 2
11 56 ft² 100______ Slab-On-Grade Edge Insulation - - - -01 ft LAUNDRY
12 9 ft² 100______ Slab-On-Grade Edge Insulation - - - -01 ft AHU CLST
13 250 ft² 100______ Slab-On-Grade Edge Insulation - - - -014 ft GREAT ROOM
14 112 ft² 100______ Slab-On-Grade Edge Insulation - - - -07 ft FOYER
15 16 ft² 100______ Slab-On-Grade Edge Insulation - - - -02 ft CLST 4
16 158 ft² 100______ Slab-On-Grade Edge Insulation - - - -030.9 ft BEDROOM 4/DE
#Type Materials Color Absor.
Roof Solar Deck
Insul.
Pitch
ROOF
Tested
Roof
Area
Gable
Area
Emitt
Tested
EmittSA
(deg)
Rad
Barr
1Hip Composition shingles 2049 ft² Medium 0.2 026.57______No0 ft² 0.9 NoN
ATTIC
#Type Ventilation Area RBS IRCCVent Ratio (1 in)
______ 1 Full attic Vented 1833 ft² N N150
1/5/2022 5:13 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
#Ceiling Type R-Value Area Framing Frac Truss Type
CEILING
Space Ins Type
1 Under Attic (Vented)30 84 ft² 0.1 Wood______M BATH Blown
2 Under Attic (Vented)30 126 ft² 0.1 Wood______M WIC Blown
3 Under Attic (Vented)30 210 ft² 0.1 Wood______MASTER BEDRO Blown
4 Under Attic (Vented)30 149 ft² 0.1 Wood______BEDROOM 3 Blown
5 Under Attic (Vented)30 16 ft² 0.1 Wood______CLST 3 Blown
6 Under Attic (Vented)30 376 ft² 0.1 Wood______KITCHEN/DININ Blown
7 Under Attic (Vented)30 72 ft² 0.1 Wood______BATH 2 Blown
8 Under Attic (Vented)30 144 ft² 0.1 Wood______BEDROOM 2 Blown
9 Under Attic (Vented)30 39 ft² 0.1 Wood______HALL Blown
10 Under Attic (Vented)30 16 ft² 0.1 Wood______CLST 2 Blown
11 Under Attic (Vented)30 56 ft² 0.1 Wood______LAUNDRY Blown
12 Under Attic (Vented)30 9 ft² 0.1 Wood______AHU CLST Blown
13 Under Attic (Vented)30 250 ft² 0.1 Wood______GREAT ROOM Blown
14 Under Attic (Vented)30 112 ft² 0.1 Wood______FOYER Blown
15 Under Attic (Vented)30 16 ft² 0.1 Wood______CLST 4 Blown
16 Under Attic (Vented)30 158 ft² 0.1 Wood______BEDROOM 4/DE Blown
17 Knee Wall (Vented)30 18 ft² 0.1 Wood______BEDROOM 2 Blown
18 Knee Wall (Vented)30 3 ft² 0.1 Wood______CLST 2 Blown
19 Knee Wall (Vented)30 10 ft² 0.1 Wood______LAUNDRY Blown
20 Knee Wall (Vented)30 22 ft² 0.1 Wood______FOYER Blown
21 Knee Wall (Vented)30 15 ft² 0.1 Wood______KITCHEN/DININ Blown
22 Knee Wall (Vented)30 21 ft² 0.1 Wood______MASTER BEDRO Blown
WALLS
#Wall Type R-Value Area
Adjacent Framing Solar
Ornt Fraction Absor.
HeightWidth
Ft In Ft InTo
Cavity Sheathing
R-ValueSpace Grade%
Below
1 4.1 0M BATH 000 6 8SE Concrete Block - Int Insul 0.20Exterior48.0 ft² ____
2 4.1 0M BATH 000 1 4 8NE Concrete Block - Int Insul 0.20Exterior112.0 ft² ____
3 4.1 0M WIC 000 9 8SE Concrete Block - Int Insul 0.20Exterior72.0 ft² ____
4 4.1 0MASTER BE 000 1 5 8SE Concrete Block - Int Insul 0.20Exterior120.0 ft² ____
5 4.1 0MASTER BE 000 1 4 8SW Concrete Block - Int Insul 0.20Exterior112.0 ft² ____
6 4.1 0BEDROOM 3 000 1 1 8NE Concrete Block - Int Insul 0.20Exterior88.0 ft² ____
7 4.1 0KITCHEN/DI 000 1 1 1 2SE Concrete Block - Int Insul 0.20Exterior132.0 ft² ____
8 4.1 0KITCHEN/DI 000 1 5 1 2SW Concrete Block - Int Insul 0.20Exterior180.0 ft² ____
9 4.1 0BATH 2 000 6 8NE Concrete Block - Int Insul 0.20Exterior48.0 ft² ____
10 4.1 0BEDROOM 2 000 1 2 8NE Concrete Block - Int Insul 0.20Exterior96.0 ft² ____
11 13 0BEDROOM 2 000 1 2 8NW Frame - Wood 0.20.1Garage96.0 ft² ____
12 13 0CLST 2 000 2 8NW Frame - Wood 0.20.1Garage16.0 ft² ____
13 13 0LAUNDRY000 7 8NW Frame - Wood 0.20.1Garage56.0 ft² ____
14 4.1 0GREAT ROO 000 1 4 1 2SW Concrete Block - Int Insul 0.20Exterior168.0 ft² ____
15 4.1 0FOYER000 7 8NW Concrete Block - Int Insul 0.20Exterior56.0 ft² ____
16 13 0FOYER000 8 8NE Frame - Wood 0.20.1Garage64.0 ft² ____
17 4.1 0CLST 4 000 2 8SW Concrete Block - Int Insul 0.20Exterior16.0 ft² ____
18 4.1 0BEDROOM 4/000 6 8NE Concrete Block - Int Insul 0.20Exterior48.0 ft² ____
1/5/2022 5:13 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
WALLS
#Wall Type R-Value Area
Adjacent Framing Solar
Ornt Fraction Absor.
HeightWidth
Ft In Ft InTo
Cavity Sheathing
R-ValueSpace Grade%
Below
19 4.1 0BEDROOM 4/000 1 3 8NW Concrete Block - Int Insul 0.20Exterior104.0 ft² ____
20 4.1 0BEDROOM 4/000 1 2 8SW Concrete Block - Int Insul 0.20Exterior96.0 ft² ____
# Ornt Panes NFRC U-Factor SHGC Area Depth Separation Int ShadeFrame Screening
WINDOWS
Overhang
Orientation shown is the entered, Proposed orientation.
Wall
ID Imp
1 SE Low-E Single 0.3 0.26 9.0 ft² 1 ft 0 in 1 ft 4 in NoneMetal None______Yes4 N
2 SW Low-E Single 0.3 0.26 15.0 ft² 8 ft 0 in 1 ft 4 in NoneMetal None______Yes5 N
3NE Low-E Single 0.3 0.26 15.0 ft² 1 ft 0 in 1 ft 4 in NoneMetal None______Yes6 N
4 SE Low-E Single 0.3 0.26 40.0 ft² 8 ft 0 in 1 ft 4 in NoneMetal None______Yes7 N
5 SW Low-E Single 0.3 0.26 15.0 ft² 1 ft 0 in 1 ft 4 in NoneMetal None______Yes8 N
6NE Low-E Single 0.3 0.26 15.0 ft² 1 ft 0 in 1 ft 4 in NoneMetal None______Yes10 N
7NW Low-E Single 0.3 0.26 15.0 ft² 1 ft 0 in 1 ft 4 in NoneMetal None______Yes19 N
# Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
GARAGE
1 441 ft² 441 ft² 21 ft 8 ft 13______
Method CFM 50 ACH 50ELASLAScope
INFILTRATION
ACHEqLA#
1430.7 578.49.000297Wholehouse .1044147.36Proposed ACH(50)1
HEATING SYSTEM
# System Type Efficiency Capacity DuctsSubtypeBlockSpeed
1 Electric Strip Heat/COP:1 27 kBtu/hr ______sys#1None1
# System Type Efficiency Capacity Air Flow SHR
COOLING SYSTEM
DuctsSubtypeBlockSubtype
1 Central Unit/SEER: 14 34 kBtu/hr 1020 cfm 0.8______sys#1Split1 Single
# System Type EF Cap Use SetPnt Conservation
HOT WATER SYSTEM
SubType Location
1 Electric 0.92 40 gal 60.9 gal 120 deg None______None Garage
1/5/2022 5:13 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
FSEC
Company Name System Model #Collector Model #
Collector
SOLAR HOT WATER SYSTEM
Storage
FEFCert #Area Volume
None None f t ² ______
# Location R-Value Area Location Area
---- Supply -------- Return ----
Leakage Type Handler
CFM 25Air
QN RLF
DUCTS
Heat Cool
HVAC #
TOT OUT
CFM25
1 Attic 6 140 ft² Attic 14 ft² Proposed Qn AHU CLST 146.6 cfm0.08 0.50______1 1 --- cfm
TEMPERATURES
Programable Thermostat: N Ceiling Fans:
Cooling [ ] Jan [ ] Feb [ ] Mar [ ] Apr [ ] May [X] Jul [X] Aug [X] Sep [ ] Oct [ ] Nov [ ] Dec
[ ] Dec
[X] Dec[X] Nov
[X] Nov
[ ] Oct
[X] Oct
[ ] Sep
[ ] Sep
[ ] Aug
[ ] Aug
[ ] Jul
[ ] Jul[ ] Jun
[ ] Jun
[X] Jun
[ ] May
[ ] May
[ ] Apr
[X] Apr
[X] Mar
[X] Mar
[X] Feb
[ ] Feb
[X] Jan
[ ] Jan
Heating
Venting
Thermostat Schedule:HERS 2006 Reference Hours
Schedule Type 12345678910 11 12
Cooling (WD)AM
PM
78
80
78
80
78
80
78
80
78
78
78
78
78
78
78
78
80
78
80
78
80
78
80
78
Cooling (WEH)AM
PM
78
80
78
80
78
80
78
80
78
78
78
78
78
78
78
78
80
78
80
78
80
78
80
78
Heating (WD)AM
PM
65
68
65
68
65
68
65
68
65
68
65
68
65
68
68
68
68
68
68
68
68
68
68
68
Heating (WEH)AM
PM
65
68
65
68
65
68
65
68
65
68
65
68
65
68
68
68
68
68
68
68
68
68
68
68
MASS
Mass Type Area T hickness Furniture Fraction Space
Default(8 lbs/sq.ft.0 ft² 0 ft 0.3 BATH 1
Default(8 lbs/sq.ft.f t ² f t 0.3 WIC 1
Default(8 lbs/sq.ft.f t ² f t 0.3 DINING
Default(8 lbs/sq.ft.f t ² f t 0.3 KITCHEN
Default(8 lbs/sq.ft.f t ² f t 0.3 UTILITY RM
Default(8 lbs/sq.ft.f t ² f t 0.3 BEDROOM 2
Default(8 lbs/sq.ft.f t ² f t 0.3 AHU CLST
Default(8 lbs/sq.ft.f t ² f t 0.3 CLST 2
Default(8 lbs/sq.ft.f t ² f t 0.3 BEDROOM 3
Default(8 lbs/sq.ft.f t ² f t 0.3 CLST 3
Default(8 lbs/sq.ft.f t ² f t 0.3 BATH 2
Default(8 lbs/sq.ft.f t ² f t 0.3 HALL
Default(8 lbs/sq.ft.f t ² f t 0.3 FOYER/GREAT RM
Default(8 lbs/sq.ft.f t ² f t 0.3 BEDROOM 1
1/5/2022 5:13 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 6 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
Project Name:
Owner:
Builder Name:
Permit Office:
Jurisdiction: ST LUCIE COUNTY
ST LUCIE COUNTY
SYNERGY BUILDERSHUDSON 4
Street:
City, State, Zip: PORT ST LUCIE , FL , 34983
430 SE GASPARILLA AVENUE
Permit Number:
Design Location: FL, MELBOURNE_REGIONAL_AP CHECKAIR BARRIER CRITERIA
A continuous air barrier shall be installed in the building envelope.
The exterior thermal envelope contains a continuous air barrier.
Breaks or joints in the air barrier shall be sealed.
The air barrier in any dropped ceiling/soffit shall be aligned with the
insulation and any gaps in the air barrier shall be sealed.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
The junction of the foundation and sill plate shall be sealed.
The junction of the top plate and the top of exterior walls shall be sealed.
Knee walls shall be sealed.
The space between window/door jambs and framing, and
skylights and framing shall be sealed.
Rim joists shall include the air barrier.
The air barrier shall be installed at any exposed edge of insulation.
Exposed earth in unvented crawl spaces shall be covered with a
Class I vapor retarder with overlapping joints taped.
Duct shafts, utility penetrations, and flue shafts opening to exterior
or unconditioned space shall be sealed.
Narrow cavities
Shafts, penetrations
Crawl space walls
Floors
(including
above-garage
and cantilevered floors)
Rim joists
Windows, skylights
Walls
Ceiling/attic
General
COMPONENT
Garage separation
Recessed lighting
Plumbing and wiring
S h o w e r / t u b
HVAC register boots HVAC supply and return register boots that penetrate building thermal
envelope shall be sealed to the sub-floor, wall covering or ceiling
The air barrier shall be installed behind electrical or communication
boxes or air-sealed boxes shall be installed.
The air barrier installed at exterior walls adjacent to showers and
tubs shall separate them from the showers and tubs.
Batt insulation shall be cut neatly to fit around wiring and
plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind piping and wiring.
Recessed light fixtures installed in the building thermal envelope shall
be sealed to the finished surface.
Air sealing shall be provided between the garage and conditioned spaces.
When required to be sealed, concealed fire sprinklers shall only be sealed
in a manner that is recommended by the manuf acturer. Caulking or other
adhesive sealants shall not be used to fill voids between fire sprinkler
cover plates and walls or ceilings.
C o n c e a l e d
Electrical/phone box on
exterior walls
Batts in narrow cavities shall be cut to fit, or narrow
cavities shall be filled by insulation that on installation
readily conforms to the available cavity spaces.
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
INSULATION INSTALLATION CRITERIA
EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software1/5/2022 5:14 PM Page 1 of 1
Air-permeable insulation shall
not be used as a sealing material.
The insulation in any dropped ceiling/soffit
shall be aligned with the air barrier.
Cavities within corners and headers of frame walls
shall be insulated by completely filling the cavity with a
material having a thermal resistance of R-3 per inch
minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and continuous
alignment with the air barrier.
Rim joists shall be insulated.
Floor framing cavity insulation shall be installed to
maintain permanent contact with the underside of
subfloor decking, or floor framing cavity insulation shall
be permitted to be in contact with the top side of
sheathing, or continuous insulation installed on the
underside of floor framing and extends from the bottom
to the top of all perimeter floor framing members.
and doors
on exterior wall
requirements
Recessed light fixtures installed in the building
thermal envelope shall be air tight and IC rated.
sprinklers
Where provided instead of floor insulation, insulation
shall be permanently attached to the crawlspace walls.
Exterior walls adjacent to showers and tubs shall be
insulated.
2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
a