Loading...
HomeMy WebLinkAboutGASPARILLA REVISION- ENERGY CALCPROJECT Title: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: ST LUCIE COUNTY ST LUCIE COUNTY SYNERGY BUILDERS 1 HUDSON 4 Family Type: New/Existing: Bedrooms: Conditioned Area: Total Stories: Worst Case: Rotate Angle:0 No 1 1833 4 New (From Plans) Detached Address Type: Lot # Block/Subdivision: PlatBook: Street: County: City, State, Zip: FL , 34983 PORT ST LUCIE , St. Lucie 430 SE GASPARILLA A Street Address Comment: GARAGE LEFT Building Type: User Cross Ventilation:No Whole House Fan:No TMY Site Design Temp Int Design Temp Heating Design Daily Temp Design Location 2.5 %97.5 %Degree Days Moisture RangeWinter Summer CLIMATE 90 70 7536969 Medium45FL_MELBOURNE_REGIOFL, MELBOURNE_REGIO______ Number Name Area Volume BLOCKS 1 Entire House 1833 17168 Number NameAreaVolume SPACES Kitchen Occupants Bedrooms Cooled HeatedInfil ID Finished 1 M BATH 84 672 No 0 Yes Yes1Yes 2M WIC 126 1008 No 0 Yes Yes1Yes 3 MASTER BEDROO 210 1680 No 01 Yes Yes1Yes 4 BEDROOM 3 149 1192 No 01 Yes Yes1Yes 5 CLST 3 16 128 No 0 Yes Yes1No 6 KITCHEN/DINING 376 4512 Yes 0 Yes Yes1Yes 7 BATH 2 72 576 No 0 Yes Yes1Yes 8 BEDROOM 2 144 1152 No 01 Yes Yes1Yes 9 HALL 39 312 No 0 Yes Yes1No 10 CLST 2 16 128 No 0 Yes Yes1No 11 LAUNDRY56448 No 0 Yes Yes1No 12 AHU CLST 9 72 No 0 Yes Yes1No 13 GREAT ROOM 250 3000 No 0 Yes Yes1Yes 14 FOYER 112 896 No 0 Yes Yes1Yes 15 CLST 4 16 128 No 0 Yes Yes1Yes 16 BEDROOM 4/DEN 158 1264 No 01 Yes Yes1Yes # Floor Type Area Tile Wood Carpet FLOORS Perimeter R-Value Joist R-ValueSpace Perimeter 1 84 ft² 100______ Slab-On-Grade Edge Insulation - - - -020 ft M BATH 2 126 ft² 100______ Slab-On-Grade Edge Insulation - - - -09 ft M WIC 1/5/2022 5:13 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT # Floor Type Area Tile Wood Carpet FLOORS Perimeter R-Value Joist R-ValueSpace Perimeter 3 210 ft² 100______ Slab-On-Grade Edge Insulation - - - -029 ft MASTER BEDRO 4 149 ft² 100______ Slab-On-Grade Edge Insulation - - - -011 ft BEDROOM 3 5 16 ft² 100______ Slab-On-Grade Edge Insulation - - - -01 ft CLST 3 6 376 ft² 100______ Slab-On-Grade Edge Insulation - - - -026 ft KITCHEN/DININ 7 72 ft² 100______ Slab-On-Grade Edge Insulation - - - -06 ft BATH 2 8 144 ft² 100______ Slab-On-Grade Edge Insulation - - - -012 ft BEDROOM 2 9 39 ft² 100______ Slab-On-Grade Edge Insulation - - - -01 ft HALL 10 16 ft² 100______ Slab-On-Grade Edge Insulation - - - -01 ft CLST 2 11 56 ft² 100______ Slab-On-Grade Edge Insulation - - - -01 ft LAUNDRY 12 9 ft² 100______ Slab-On-Grade Edge Insulation - - - -01 ft AHU CLST 13 250 ft² 100______ Slab-On-Grade Edge Insulation - - - -014 ft GREAT ROOM 14 112 ft² 100______ Slab-On-Grade Edge Insulation - - - -07 ft FOYER 15 16 ft² 100______ Slab-On-Grade Edge Insulation - - - -02 ft CLST 4 16 158 ft² 100______ Slab-On-Grade Edge Insulation - - - -030.9 ft BEDROOM 4/DE #Type Materials Color Absor. Roof Solar Deck Insul. Pitch ROOF Tested Roof Area Gable Area Emitt Tested EmittSA (deg) Rad Barr 1Hip Composition shingles 2049 ft² Medium 0.2 026.57______No0 ft² 0.9 NoN ATTIC #Type Ventilation Area RBS IRCCVent Ratio (1 in) ______ 1 Full attic Vented 1833 ft² N N150 1/5/2022 5:13 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT #Ceiling Type R-Value Area Framing Frac Truss Type CEILING Space Ins Type 1 Under Attic (Vented)30 84 ft² 0.1 Wood______M BATH Blown 2 Under Attic (Vented)30 126 ft² 0.1 Wood______M WIC Blown 3 Under Attic (Vented)30 210 ft² 0.1 Wood______MASTER BEDRO Blown 4 Under Attic (Vented)30 149 ft² 0.1 Wood______BEDROOM 3 Blown 5 Under Attic (Vented)30 16 ft² 0.1 Wood______CLST 3 Blown 6 Under Attic (Vented)30 376 ft² 0.1 Wood______KITCHEN/DININ Blown 7 Under Attic (Vented)30 72 ft² 0.1 Wood______BATH 2 Blown 8 Under Attic (Vented)30 144 ft² 0.1 Wood______BEDROOM 2 Blown 9 Under Attic (Vented)30 39 ft² 0.1 Wood______HALL Blown 10 Under Attic (Vented)30 16 ft² 0.1 Wood______CLST 2 Blown 11 Under Attic (Vented)30 56 ft² 0.1 Wood______LAUNDRY Blown 12 Under Attic (Vented)30 9 ft² 0.1 Wood______AHU CLST Blown 13 Under Attic (Vented)30 250 ft² 0.1 Wood______GREAT ROOM Blown 14 Under Attic (Vented)30 112 ft² 0.1 Wood______FOYER Blown 15 Under Attic (Vented)30 16 ft² 0.1 Wood______CLST 4 Blown 16 Under Attic (Vented)30 158 ft² 0.1 Wood______BEDROOM 4/DE Blown 17 Knee Wall (Vented)30 18 ft² 0.1 Wood______BEDROOM 2 Blown 18 Knee Wall (Vented)30 3 ft² 0.1 Wood______CLST 2 Blown 19 Knee Wall (Vented)30 10 ft² 0.1 Wood______LAUNDRY Blown 20 Knee Wall (Vented)30 22 ft² 0.1 Wood______FOYER Blown 21 Knee Wall (Vented)30 15 ft² 0.1 Wood______KITCHEN/DININ Blown 22 Knee Wall (Vented)30 21 ft² 0.1 Wood______MASTER BEDRO Blown WALLS #Wall Type R-Value Area Adjacent Framing Solar Ornt Fraction Absor. HeightWidth Ft In Ft InTo Cavity Sheathing R-ValueSpace Grade% Below 1 4.1 0M BATH 000 6 8SE Concrete Block - Int Insul 0.20Exterior48.0 ft² ____ 2 4.1 0M BATH 000 1 4 8NE Concrete Block - Int Insul 0.20Exterior112.0 ft² ____ 3 4.1 0M WIC 000 9 8SE Concrete Block - Int Insul 0.20Exterior72.0 ft² ____ 4 4.1 0MASTER BE 000 1 5 8SE Concrete Block - Int Insul 0.20Exterior120.0 ft² ____ 5 4.1 0MASTER BE 000 1 4 8SW Concrete Block - Int Insul 0.20Exterior112.0 ft² ____ 6 4.1 0BEDROOM 3 000 1 1 8NE Concrete Block - Int Insul 0.20Exterior88.0 ft² ____ 7 4.1 0KITCHEN/DI 000 1 1 1 2SE Concrete Block - Int Insul 0.20Exterior132.0 ft² ____ 8 4.1 0KITCHEN/DI 000 1 5 1 2SW Concrete Block - Int Insul 0.20Exterior180.0 ft² ____ 9 4.1 0BATH 2 000 6 8NE Concrete Block - Int Insul 0.20Exterior48.0 ft² ____ 10 4.1 0BEDROOM 2 000 1 2 8NE Concrete Block - Int Insul 0.20Exterior96.0 ft² ____ 11 13 0BEDROOM 2 000 1 2 8NW Frame - Wood 0.20.1Garage96.0 ft² ____ 12 13 0CLST 2 000 2 8NW Frame - Wood 0.20.1Garage16.0 ft² ____ 13 13 0LAUNDRY000 7 8NW Frame - Wood 0.20.1Garage56.0 ft² ____ 14 4.1 0GREAT ROO 000 1 4 1 2SW Concrete Block - Int Insul 0.20Exterior168.0 ft² ____ 15 4.1 0FOYER000 7 8NW Concrete Block - Int Insul 0.20Exterior56.0 ft² ____ 16 13 0FOYER000 8 8NE Frame - Wood 0.20.1Garage64.0 ft² ____ 17 4.1 0CLST 4 000 2 8SW Concrete Block - Int Insul 0.20Exterior16.0 ft² ____ 18 4.1 0BEDROOM 4/000 6 8NE Concrete Block - Int Insul 0.20Exterior48.0 ft² ____ 1/5/2022 5:13 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS #Wall Type R-Value Area Adjacent Framing Solar Ornt Fraction Absor. HeightWidth Ft In Ft InTo Cavity Sheathing R-ValueSpace Grade% Below 19 4.1 0BEDROOM 4/000 1 3 8NW Concrete Block - Int Insul 0.20Exterior104.0 ft² ____ 20 4.1 0BEDROOM 4/000 1 2 8SW Concrete Block - Int Insul 0.20Exterior96.0 ft² ____ # Ornt Panes NFRC U-Factor SHGC Area Depth Separation Int ShadeFrame Screening WINDOWS Overhang Orientation shown is the entered, Proposed orientation. Wall ID Imp 1 SE Low-E Single 0.3 0.26 9.0 ft² 1 ft 0 in 1 ft 4 in NoneMetal None______Yes4 N 2 SW Low-E Single 0.3 0.26 15.0 ft² 8 ft 0 in 1 ft 4 in NoneMetal None______Yes5 N 3NE Low-E Single 0.3 0.26 15.0 ft² 1 ft 0 in 1 ft 4 in NoneMetal None______Yes6 N 4 SE Low-E Single 0.3 0.26 40.0 ft² 8 ft 0 in 1 ft 4 in NoneMetal None______Yes7 N 5 SW Low-E Single 0.3 0.26 15.0 ft² 1 ft 0 in 1 ft 4 in NoneMetal None______Yes8 N 6NE Low-E Single 0.3 0.26 15.0 ft² 1 ft 0 in 1 ft 4 in NoneMetal None______Yes10 N 7NW Low-E Single 0.3 0.26 15.0 ft² 1 ft 0 in 1 ft 4 in NoneMetal None______Yes19 N # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation GARAGE 1 441 ft² 441 ft² 21 ft 8 ft 13______ Method CFM 50 ACH 50ELASLAScope INFILTRATION ACHEqLA# 1430.7 578.49.000297Wholehouse .1044147.36Proposed ACH(50)1 HEATING SYSTEM # System Type Efficiency Capacity DuctsSubtypeBlockSpeed 1 Electric Strip Heat/COP:1 27 kBtu/hr ______sys#1None1 # System Type Efficiency Capacity Air Flow SHR COOLING SYSTEM DuctsSubtypeBlockSubtype 1 Central Unit/SEER: 14 34 kBtu/hr 1020 cfm 0.8______sys#1Split1 Single # System Type EF Cap Use SetPnt Conservation HOT WATER SYSTEM SubType Location 1 Electric 0.92 40 gal 60.9 gal 120 deg None______None Garage 1/5/2022 5:13 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT FSEC Company Name System Model #Collector Model # Collector SOLAR HOT WATER SYSTEM Storage FEFCert #Area Volume None None f t ² ______ # Location R-Value Area Location Area ---- Supply -------- Return ---- Leakage Type Handler CFM 25Air QN RLF DUCTS Heat Cool HVAC # TOT OUT CFM25 1 Attic 6 140 ft² Attic 14 ft² Proposed Qn AHU CLST 146.6 cfm0.08 0.50______1 1 --- cfm TEMPERATURES Programable Thermostat: N Ceiling Fans: Cooling [ ] Jan [ ] Feb [ ] Mar [ ] Apr [ ] May [X] Jul [X] Aug [X] Sep [ ] Oct [ ] Nov [ ] Dec [ ] Dec [X] Dec[X] Nov [X] Nov [ ] Oct [X] Oct [ ] Sep [ ] Sep [ ] Aug [ ] Aug [ ] Jul [ ] Jul[ ] Jun [ ] Jun [X] Jun [ ] May [ ] May [ ] Apr [X] Apr [X] Mar [X] Mar [X] Feb [ ] Feb [X] Jan [ ] Jan Heating Venting Thermostat Schedule:HERS 2006 Reference Hours Schedule Type 12345678910 11 12 Cooling (WD)AM PM 78 80 78 80 78 80 78 80 78 78 78 78 78 78 78 78 80 78 80 78 80 78 80 78 Cooling (WEH)AM PM 78 80 78 80 78 80 78 80 78 78 78 78 78 78 78 78 80 78 80 78 80 78 80 78 Heating (WD)AM PM 65 68 65 68 65 68 65 68 65 68 65 68 65 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH)AM PM 65 68 65 68 65 68 65 68 65 68 65 68 65 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area T hickness Furniture Fraction Space Default(8 lbs/sq.ft.0 ft² 0 ft 0.3 BATH 1 Default(8 lbs/sq.ft.f t ² f t 0.3 WIC 1 Default(8 lbs/sq.ft.f t ² f t 0.3 DINING Default(8 lbs/sq.ft.f t ² f t 0.3 KITCHEN Default(8 lbs/sq.ft.f t ² f t 0.3 UTILITY RM Default(8 lbs/sq.ft.f t ² f t 0.3 BEDROOM 2 Default(8 lbs/sq.ft.f t ² f t 0.3 AHU CLST Default(8 lbs/sq.ft.f t ² f t 0.3 CLST 2 Default(8 lbs/sq.ft.f t ² f t 0.3 BEDROOM 3 Default(8 lbs/sq.ft.f t ² f t 0.3 CLST 3 Default(8 lbs/sq.ft.f t ² f t 0.3 BATH 2 Default(8 lbs/sq.ft.f t ² f t 0.3 HALL Default(8 lbs/sq.ft.f t ² f t 0.3 FOYER/GREAT RM Default(8 lbs/sq.ft.f t ² f t 0.3 BEDROOM 1 1/5/2022 5:13 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 6 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT Project Name: Owner: Builder Name: Permit Office: Jurisdiction: ST LUCIE COUNTY ST LUCIE COUNTY SYNERGY BUILDERSHUDSON 4 Street: City, State, Zip: PORT ST LUCIE , FL , 34983 430 SE GASPARILLA AVENUE Permit Number: Design Location: FL, MELBOURNE_REGIONAL_AP CHECKAIR BARRIER CRITERIA A continuous air barrier shall be installed in the building envelope. The exterior thermal envelope contains a continuous air barrier. Breaks or joints in the air barrier shall be sealed. The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. The junction of the foundation and sill plate shall be sealed. The junction of the top plate and the top of exterior walls shall be sealed. Knee walls shall be sealed. The space between window/door jambs and framing, and skylights and framing shall be sealed. Rim joists shall include the air barrier. The air barrier shall be installed at any exposed edge of insulation. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Narrow cavities Shafts, penetrations Crawl space walls Floors (including above-garage and cantilevered floors) Rim joists Windows, skylights Walls Ceiling/attic General COMPONENT Garage separation Recessed lighting Plumbing and wiring S h o w e r / t u b HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub-floor, wall covering or ceiling The air barrier shall be installed behind electrical or communication boxes or air-sealed boxes shall be installed. The air barrier installed at exterior walls adjacent to showers and tubs shall separate them from the showers and tubs. Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Recessed light fixtures installed in the building thermal envelope shall be sealed to the finished surface. Air sealing shall be provided between the garage and conditioned spaces. When required to be sealed, concealed fire sprinklers shall only be sealed in a manner that is recommended by the manuf acturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and walls or ceilings. C o n c e a l e d Electrical/phone box on exterior walls Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA INSULATION INSTALLATION CRITERIA EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software1/5/2022 5:14 PM Page 1 of 1 Air-permeable insulation shall not be used as a sealing material. The insulation in any dropped ceiling/soffit shall be aligned with the air barrier. Cavities within corners and headers of frame walls shall be insulated by completely filling the cavity with a material having a thermal resistance of R-3 per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Rim joists shall be insulated. Floor framing cavity insulation shall be installed to maintain permanent contact with the underside of subfloor decking, or floor framing cavity insulation shall be permitted to be in contact with the top side of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. and doors on exterior wall requirements Recessed light fixtures installed in the building thermal envelope shall be air tight and IC rated. sprinklers Where provided instead of floor insulation, insulation shall be permanently attached to the crawlspace walls. Exterior walls adjacent to showers and tubs shall be insulated. 2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. a