Loading...
HomeMy WebLinkAboutROOFING PERMIT INFORMATION SHEET 4-1LUc[ 1 - ST. LUCIE WORKS 4 1 ti �-- w — Garage Buiidin �IE C NTY ROOFING PERMIT INFORMATION SHEET Florida Building Code 7th Edition (2020) Based on Section 1525 of the Florida Building Code-Building INSTRUCTION PAGE COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING SHEET APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED BELOW: Highlight System Required Sections of Attachments Required Roof System the Permit Application See List Below Form Low Slope Application A, B,C lA3,4,6,6,7 Prescriptive BUR-RAS 150 A,B,C 2,4,5,6,7 Asphaltic Shingles A, B, D 1,2,4,5,6,7 Concrete or Clay Tile A, B, D,E Metal Roofs A,B,D 1,2,3,4,5,6,7' Wood Shingles and A, B, D 1,2,4,6,6,7 iShakes Other As Applicable y,2,3,4,5,8,7 ATTACHMENTS REQUIRED As Applicable): 1. Fire Directory Listing Page NIA X2. From Product Approval: Front Page Specific System Description Specific System Limitations General Limitations Applicable Detail Drawings X 3. Design Calculations per Chapter 15,or if applicable, RAS 127 or RAS 128 X4. Other Component of Product Approval X 5. Municipal Permit Application X 5. Owners Notification for Roofing Considerations(Reroofing Only) x 7. Any Required Roof Testing/Calculation Documentation Form Roofinfofeb2l Rev Feb 18,2021 Garage Building Section D (Steep Slope Roof System) Roof System manufacturer: Notice of Acceptance Number: FL25G2182 �F Minimum Design Wind Pressures, If Applicable(From RAS 127 or Calculations); Zone Zone 2e73$gZone 2n:44•0 Zone 2r- AZone 3e: _ Lone 3r:W"� Deck Type: Plvwood Type Underlayment Roof Slope: 3192- Insulation: La Fire Barrier: FRidge Ventilation? Fastener Type&Spacing: Adhesive Type: Type Gap Sheet KMeawnRoof KEejght: 20 Roof Covering: Standing Rearn Type&Size Drip Edge: ST. LUCIE ►CORKS Garage Building Section A (General Information) Master Permit No. Process No, Contractors Name: Dee Keihn License# CCC1331408 Job Add res ROOF CATEG DRY ❑Low Slope ❑Mechanically Fastened Tile ❑Mortar/Adhesive Set Tiles ❑Asphaltic Shingles ®Metal Panel/Shingles QWood Shingles/Shakes ❑ Prescriptive BUR-RAS 150 ROOF ROOF TYPE, 0 New roof ❑ Repair ❑ Maintenance IS Reroofing ❑Recovering -ROOF SYSTEM INFORMATION Low Slope Roof Area(SF) Steep Sloped Roof Area (SF)l 1 Total (SF) Section B(Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels,clearly identify dimensions of elevated pressure zones and location of parapets, 1 4 I I I , k 1 ` 1 MEASUREMENTS W'3^ 89^ r• 7ea_ /e'a--r-27 16r 71'a• 1' Irs. Ire* 1Ta• SSa" � Eave i Hip - Wall �-- Rake ..wx Valley PE1ch Change �� Ridge Step Unlabeled SQUARES LINE MEASUREMENTS Actual Squares: 54.81 Sqs. Eaves: 346 Ft. Total Squares Rakes: 50 Ft. (Inc. Waste at 7 %): 58.75 Sqs. Ridges: 72 Ft. Hips: 153 Ft. Valleys: 0 Ft. Step: 0 Ft. Wall: 0 Ft. PITCH MEASUREMENTS Pitch Change: 145 Ft. CATEGORY MEASUREMENTS Pitch 2112: 29.13 Sqs. i#ch 3112: 11,24 Sqs. Ice 8r,Water Shield: 0 Ft. Pitch 10I12: 14.44 Sqs, Ridge Vent: 0 Ft. Rake Edge: 0 Ft. Eave Edge: 0 Ft. Step Flashing: 0 Ft. Apron Flashing: 0 Ft. Gutters: 0 Ft. Gutter Toppers: 0 Ft. Down Spouts: 0 Ft,