Loading...
HomeMy WebLinkAboutBuilding PlansSCOPE OF WORK Planning & Development Services Department Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1SS3 Certification for Design Load Compliance Project Name: BUSH ADDITION Project Address: 11122 ORANGE AVE Permit #: Occupancy Type: R Construction Type: V INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition1. a Any accessory structure requiring a building permit tt° ., o Any non-residential structure. �.. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida Building Code 2010 Edition with 2010 Supplements using ASCE 7-10 2. Structure Designed as (check one): X Enclosed Partially Enclosed Open 3. Risk Category: I X it 111 IV Exposure Category: X 13 C D 4. Design Wind Velocity 160 mph 124 ASD N/A LRFD End Zone Width: 5 ft S. Mean Roof Height: 15 ft Roof Pitch: 2 :12 Parapet: N/A ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): 16.0 16.0 16.0 2T6 27.6 N/A Zane 1: Zone 2: Zone 3: Zone 4: Zone 5: Garage: -25.3 -44.0 -65.1 -30.0 -37.0 N/A 7. Design Loads: Floor: 40 PSF Roof/Dead: 5 PSF Roof/Live: 20 Balcony:. N/A PSF Dock: N/A PSF Deck: N/A PSF Stairs: N/A PSF Fence: N/A PSF Railings: _N/A PLF / CONCENTRATED 8. Were Shear Walls Considered For Structure? X Yes Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes current) adopted and enforced b St. Lucie a app cab p o e g y op ed y County. I also certify that structural elements depicted on these plans provide adequate resistance to the design forces specified:/ ON PLAN 10/9/2015 Signature, Date, and Seal Print Name Cert # & Co. Cert Auth. Paul Welch Inc 1984 S.W. Biltmore St. Suite #114 Port St. Lucie, FL Company Name & Address LINTEL SCHEDULE - DEMOLISH EXISTING CARPORT AND FRAMED ADDITION. - CONSTRUCT NEW CARPORT AND ADDITION IN ITS PLACE PER PLANS. - INSTALL NEW ROOFING ON ENTIRE RESIDENCE PER PLAN. WALL FINISIi / INSULATION NOTES ' ' Planning & Development Services Department 1) INTERIOR TO BE %" DRYWALL FINISH. { • Building & Regulations Division ALL MANUFACTURES _ 2) ALL INTERIOR GYPSUM BOARD TO BE MIN. %" THICK WITH (13 GAGE, 1 3/8" llkiF Rim", Product Review Affidavit LACLES SHOWING U FACTORS AND SHGC COMPLIANCE THIS IS AN ALTERATION LEVEL 2 AND MUST' COMPLY WITH THE FBC 2014 FOR LONG,19/64" HEAD; 0.098" DIAMETER, 1'/4" LONG, ANNULAR -RINGED; 5D COOLER NAIL, 0.086" DIAMETER, 1 5/8" LONG, 15/64" HEAD; OR GYPSUM BOARD WITH FCC ENERGY CODE MUST EXISTING BUILDINGS CHAPTER 7 AND 8. NAIL, 0.086" DIAMETER, 1 5/8" LONG, 9/32" HEAD) SPACED AT 7" O.C. FOR NAILS Building Permit # REMAIN ON ALL DOORS AND WINDOWS Owners Name BUSH RESIDENCE Applia T L INSPECTIONS ARE APPROVED NOTES: ALL AND 12" O.C. FOR SCREWS. 3) WALLS AT SHOWER TO BE TILE. PROVIDE CEMENT, FIBER -CEMENT OR GLASS 1) TILE CONTRACTOR, SUBCONTRACTOR, SUPPLIER, ECT. SHALL VERIFY MAT GYPSUM. BACKERS IN COMPLIANCE WITH ASTM C 1288, C 1325, C 1178, OR DIMENSIONS, CONDITIONS AT JOB SITE, PLANS, SPECIFICATIONS, ECT. C 1278 AND INSTALLED IN ACCORDANCE WITH MANUFACTURERS' Product Opening Design Pressures Product Rated Design Pressure Manufacturer Model Number Product Approval Number Glass Type Method of Attach merit Windows SEE ELEVS +/- 45 PGT SH2O0 FL# 1435.1 NON_IMPACT 1i4" X 1 3/8" MIN, EMBED ULTRACONS AT 9" / 23" O.C. Mullions N/A Fixed Glass N/A Block Glass N/A Skylights ^� 4 cp 5 4tR@�4 I� I� �r.l f ��`�� �1 �•Q (r, �f +F��t #O K -1 z" AJ— D14 je,,- 1 '.> Sliding Glass Doors. N/A ''.� "'�.,�� `j .�. '"�^�„���,.„�<�"•�' s��� � � � Swing Type Doors SEE EL.EVS +/- 67 THERMA-TRU SMOOTH STAR FL# 15225.5 N/A 1/4" X 1 1/4" MIN. EMBEDPCONS AT 4" / 15.15" O.C. French Doors N/A Garage Doors _ N/A Hurricane Protection SEE EL_EVS +/- 50 EASTERN METAL SUPPLY 0.05ALUMINIMUM FL# 11964.1 N/A 1/4" X 2" EMBED ELCO PANELMATES OR TAPCONS AT 2" / 6" O.C. Roof Ventilation N/A Roofing Material FF e"r !� � pr }( r/ `� ! E. sy� .� �lN,ra� p//j^ /g 1 6 P !M 71, P � .A' F Revised 07/22/201.4 2) STRUCTURAL FEATURES NOT DETAILED ON THESE PLANS WILL BE RECOMMENDATIONS AS BACKERS FOR WALL TILE IN TUB AND SHOWER ADDRESSED BY THE ENGINEER AS CONSTRUCTION PROGRESSES. AREAS AND WALL PANELS IN SHOWER AREAS. (PER FRC 702.4.1 & FRC 702.4.2). 3) ALL WRITTEN DIMENSIONS ON THESE DRAWINGS TAKE PRECEDENCE OVER 4) WALL AND CEILING FINISHES SHALL HAVE A SMOKE -DEVELOPED INDEX OF SCALED DIMENSIONS. NOT GREATER THAN 450. 4) ALL CONSTRUCTION MUST COMPLY WITH THE FLORIDA BUILDING CODE 5) WALL AND CEILING FINISHES SHALL HAVE A FLAME -SPREAD (FBC) 2014, FBC 2014 RESIDENTIAL, FBC 2014 PLUMBING CODE, FBC 2014 CLASSIFICATION OF NOT GREATER. THAN 200. MECHANICAL CODE, FBC 2014 ENERGY CONSERVATION, AND THE NEC (NFPA 6) ALL EXPOSED INSULATION MATERIALS INSTALLED ON ATTIC FLOORS SHALL 70) 2011 EDITION. HAVE A CRITICAL RADIANT FLUX NOT LESS THAN 0.12 WATT PER SQUARE 5) RESIDENCE LOCATED IN NEGLIGIBLE WEATHERING AREA, AND IN VERY HEAVY CENTIMETER. EXPOSED FOAM PLASTIC INSULATION MATERIALS EXPOSED TO 6) TERMITE INFESTATION AREA PER FRC 301. ALL ADDITIONS, REPAIRS, AND ALTERATIONS MUST COMPLY WITH THE F.B.0 THE UNDERSIDE OF THE ROOF DECK OR ON THE ATTIC WALLS SHALL 2014 FOR EXISTING BUILDINGS. COMPLY WITH SECTION FRC316. .^ 7) PER FRC 702.2".1 ALL GYPSUM BOARD MATERIALS AND ACCESSORIES SHALL STRUCTURAL NOTES CONFORM TO ASTM C 36, C 79, C 475, C 514, C 630, C 931, C 960, C 1002, C I047, C 1) DESIGN LOADS IN ACCORDANCE WITH ASCE7-10. 1177, C 1178; C 1278, C 1395, C 1396 OR C 1658 AND SHALL BE INSTALLED IN ACCORDANCE WITH THE PROVISIONS OF FRC, AND ADHESIVES FOR THE 2) SOIL BEARING CAPACITY: 2500 PSF (MIN.). INSTALLATION OF GYPSUM BOARD SHALL CONFORM TO ASTM C 557 3) ALL STRUCTURAL CONCRETE IN BEAMS, LINTELS, VERTICLE CELLS, AND 8) INSULATION MATERIALS, INCLUDING FACINGS, SUCH AS VAPOR RETARDERS COLUMNS SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI OR VAPOR PERMEABLE MEMBRANES INSTALLED WITHIN FLOOR -CEILING COMPRESSIVE STRENGTH AT 28 DAYS. ASSEMBLIES, ASSEMBLIES ROOF -CEILING ASSEMBLIES WALL ASSEMBLIES CRAWL 4) SLAB /FOOTINGS TO BE CONCRETE WITH A I�IINIIIIUI'YI 2500 PSI COMPRESSIVE AND ATTICS SHALL HAVE A FLAME SPREAD INDEX NOT TO EXCEED 25 STRENGTH AT 28 DAYS. SEE PLAN FOR SIZES &STEEL REQUIREMENTS. WITH AN ACCOMPANYING SMOKE -DEVELOPED INDEX NOT TO EXCEED 450 5) MINIMUM CONCRETE PROTECTION FOR REINFORCING BARS: WHEN TESTED IN ACCORDANCE 'WITH ASTM E 84 OR UL 723. FOOTLNGS• 3" BEAMS: 1 1/2" SUSPENDED SLABS: I Y,." 6) LAP ALL REINFORCING STEEL A MINIMUM OF 48 BAR DIAMETERS EXCEPT AS NOTED GRADE 60 STEEL MINIMUIII IN BEAMS AND COLUMNS. ENERGY CONSERVATION NOTES 7) ALL LUMBER IN CONTACT WITH CONCRETE OR MASONRY SHALL BE 1.) RESIDENCE SHALL BE IN ACCORDANCE WITH FLORIDA BUILDING CODE 2014 E.RGY CONSER?ATION,.RESiDEN I IAL _- . PRESSURE TREATED.. It nave reviewed the above components or cladding and I have approved their use in this structure. These products provide adequate resistance to the - - 2) CEILINGS -it _ ' 8) SPLITING OR CRACK OF STRUCTURAL COMPONENTS DUE TO wind loads and forces specified by current code provisions. "3 "-'I'"CIC ACCESS DOERS OR HATCHES FROM CONDITIOND SPACES TO INSTALATION OF HARDWARE IS NOT PERMITED. � iJNCONDITIONED SPACES SHALL BE WEATHERSTRIPPED AND PAUL WELCH P.E.. 9) UNLESS OTHERWISE NOTED, THE INSTALLATION OF SPECIFIED HARDWARE INSULATED TO Name: ^_ Signature: SHALL CONFORM TO THE MANUFACTURES INSTRUCTIONS AND STANDARD A LEVEL EQUIVALENT TO THE INSULATION ON THE SURROUNDING PAUL WELCH INC 29945 ON PLAN PRACTICIES. a SURFACES, A WOOD FRAMED OR EQUIVALENT BAFFLE OR RETAINER IS Design Prof: Cert. No. Date: � 10) UNLESS OTHERWISE NOTED INTERIOR DRYWALL IS TO BE NAILED WITH 10d t,� �°, /�' REQUIRED TO BE PROVIDED WHEN LOOSE FILL IS INSTALLED, TO PREVENT •_ ,,. OR BETTER NAILS 6 O.C. EDGES, AND 6 O.C. FIELD, OR SCREWED WITH vf . LOOSE FILL FROM SPILLING INTO THE LIVING SPACE. " "" T ""� °' DRYWALL SCREWS 1.5" LONG AND 0.131 DIA. 4) THEBUILDING THERMAL ENVELOPE SHALL BE CONSTRUCTED TO LIMIT AIR 11) LINTELS SHALL HAVE A MINIMUM 4" BEARINGLEAKAGE IN ACCORDANCE WITH THE REQUIREMENTS R402.4.1 THROUGHEXCEPT RECESSED LINTELS Q SHALL HAVE 8" BEARING R402.4.4. f r` 'b SUN- (o=R, WMAR SylenG"I 14 {{?} 1G X 7 PAN HEAD FcRfl`t (12) - 4/♦" % 3/16 - 1/4- GRP Ail AfAD"MINUO LARGE FtAtiGE RNF.1 J -" ,l V (1) ALL ROOrIK DF rAII S SMALL COMRY W(Ri CHAPTtIl ar*, 2014 Lr)ITION a+ of 11PE rLoRibA tiuiioiNG (2) 4' 10NIhluM DISTANCE FROM ANGLE: Lil" 10 POoF SURFACE is FOR 'r.HINC, X OR Crr III _. OP ROOF y WITH OUT INsctr.ATION. FOR IIasUlhttON AND TirvE ADD THE: TILE liclou (3) ANCHOR TO Of, kWE OF NON ,COR'RGIVE MATT RIA1. , s'OMPAfAMr.. 'tYfIH ALOYtNUM LINTEL # LENGTH / TYPE SAFE GRAVITY LOAD APPLIED GRAVITY LOAD SAFE UPLIFT LOAD APPLIED UPLIFT LOAD COMPOSITE BEAM. L-I 10'-6" 120" U-LINTELS 1533 500 914 300 8F161B-1T L-2 9'-4" 112" U-LINTELS 1843 500 1.133 300 8F161B-IT L-3 T-6" 90" U-LINTELS 2661 500 1634 300 8F161B-IT L-4 5'-8" 68" U-LINTELS 4567 500 1960 300 8RF14 IB-IT L-5 4'-6" 54" U-LINTELS 6133 500 2724 300 8F161B-1T L-6 4'-6" 54" U-LINTELS 5206 500 2525 300 8RF14 1B-IT NOTE: WHEN LINTEL IS IN VARIOUS LOCAL DONS, WORN I CANE LUAllINU IN NItUWN NOTE: PROVIDE "CASTCRETE" PRE -CAST CONCREE LINTEL AS NOTED ON PLANS. 14 R402.4.1 2 Testing. The building ci,'-dwelling unit shall be tested and verified as having an,-* leakage rate Of not exceeding 5 all' changes per hour In Climate Zones 1 and 2, and 3 air €;hanges per hoar in Climate ZoneS 3 through 8. Testing sp; all be conducted with a blower door at a pressure of 0.2 inches W.g. (50 Pascals,), Where required by the code official, testing shall be conducted by an approved third party. A written report of the results of the test shall be Signed by the pally conducting the test and provided to the code official. Testing shall be performed at any tinge after creation of all penetrations of the building thermal envelope. During testing: 9 Exte(lor windows and doors, fireplace and stove doors shall be closed. but not sealed, beyond the intended weatherstripping psi- other infiltration control measures: t 2. Dampers including exhaust, intake, makeup alr, backdraft and flue dampers shall be closed; but not sealed beyond Intender! Infiltration control measures; 3, Interior doors, if installed at the time of the test, shall be open; 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed acid sealed; 5. Heating and cooling systems' it installed at the time of the test, shall be turned off; and .' ppy and return registers if installed at the tinge of the test Shall i3e fully Operl. 12) EXTERIOR CEILING AND SOFFIT SHALL BE P.T.'h" CDX PLYWOOD SHEATHING 5) THE BUILDING SHALL BE TESTED FOR AIR LEAKAGE IN ACCORDANCE WITH 910 To occx 0FC Tty " kFauirfE�tENrS `i , . ; WITH #12 X 3" S.S. SCREWS AT 4" O.C. PERIMETER AND 6" O.C. FIELD ALL ' 402.4.1.2 Iry x �-ty�" rzFrx SCREWS » 6 WI D �� era srpr 11, TaTAL » N OWS, SKYLIGHTS, AND SLIDING GLASS DOORS SHALL HAVE AN AIR o rfr f` FER SI i(?A.c OT rsr I SOFFITS AND EXTERIOR CEILING SHALL BE PAINTED. PROVIDE 4 X 22 ) " INFILTRATION RATE OF NO .MORE .THAN 0.3 CFM PER SQUARE FT, AND _ SCREENED VENTS AT 48" O.C. FOR SOFFITS SWINGING DOORS NO M 5 Q r _ _. - -. -- __ N At I _ _ EU 1YYE DESIGN ,�. G - cnpl.00 Pr 3 S �aAtI:R IEsp PRESSURE 15 Ps .' %I f, r t ' 13) EXTERIOR FRAME WALLS TO BE %" T1-11 WITH IOD NAILS TO STUDS @ 6" O.C. ORE THAN 0._ CFM PER SQUARE FT AND MUST BE TESTED LISTED AND LABELED IN ACCORDANCE WITH R402.4.3, -WO POLYCARDONATr TIANt PERIMETER AND FIELD OVER (1) LAYERS OF (15# FELT OR TYVAK BUILDING . AL ror YcArzgoN}1 Elva 41 7) CONTRACTOR SHALL PROVIDE ENERGY PERFORMANCE LEVEL (EPL) DISPLAY ITAI..RAM NOA 1£1�C1913.C7' PAk.:S41N SHIEf f IELD NOA 10 0329.03, MAKROU)N GP 14) BEARING POINTS OF TRUSSES SHALL HAVE VERTICAL STUDS IN A NUMBER CARD IN ACCORDANCE WITH FBC 2014 ENERGY CONSERVATION R401.3. SAF31C NOA 083 0305,02i (.FXAN 9034 -- - EQUAL TO THE NUMBER OF PLIES OF THE BEARING MEMBER WHEN THE j1 BEARING MEMBER IS (2) OR MORE PLIES UNLESS NOTED. r " �1ffq„�'� 4 , . I "" 1" ,"< �� • it SUJEC; TO YC0 RI:TIW 4"Alk MAY i3f- ?NEB S a ��� �l .s`� =p�I 44 I r E_III 4 tG r1 )3 DPIJ II47 fi1 -"� 14,A,t.1= WA 1..."L..- v�A Q AIL- 1" T. i ' (T1 c r1r �; r sz ,. j`Tr ilT�*(_ T:WIQ,O, r " 1.. t 1 " r i. 4-� i?.i t I r{_ i 3'1 Sz 111 — 0 ` LC I T +�N FO , .. ., is I L tEF- i'l e—K l oLt11^11,1 7�4 '/l e vlx V lol _I --- 1/� t 2 bind. +ralWt;1PAa rAe't e,o L� lJ f-1 Q I""� IJ IpJ fP1 roe 141-d06 O'er K,, r"'L 1/4 0 `C-m wA I-L- -(-rel ) 1TD - TUT L 14 I ---- 3 0 6 8 GLAZED DR" W/ 14" SIDELFIFE ----- 3 0 6 8 GLAZED DR. 3 ----- (DBL) 36" W X 42" H S.H. WINDOW 4 ----- 36" W X 42" H S.H. WINDOW TABULATION CARPORT 440 S.F. COV. PORCH 194 S.F. NEW LIVING 340 S.F. TOTAL 974 S.F. PAUL WELCH INC. 611ECHANICAL * ELECTRICAL * C;IVII 1984 S.W. BILTMORE ST. SUI NA PORT SAINT Lucm, FL 384 --- "V PHONE PHONES EMAIL 1 (ia 785 - 9888 PWE'LCHINC@AOL: I� PAUL WELCH P.E. FL. REG. No. 29945 a j(3) -16D NAILS (TYPICAL•) fill 2 X 4 "X" BRACING AT RIDGE AND 6 FEET O.C. EACH SIDE OF RIDGE 2 X 4 SPRUCE ORBETTE1 I LATERAL BRACE AT 6 FEET O.C. FASTENED TO TOP OF BOTTOM CHORD OF TRUSSES WITH (2) -16d NAILS BACK AT GABLE END TRUSS AND 4 TRUSSES BACK CEASING PER PLAN P.T. 2 X 8 CONTINUOUS WITH W •,•i "F' BOLT OR W X 5'IV WEDGE ` ANCHOR AT 24" O.C. WITH 2" X 2" X I/8" WASHERS ROOFING, / UNMRLAYMHNT PEF PLAN 1913V ROOF SHEATHINO ALUM DRIP EDGE 2X P.T. WOOD FASCIA SOFFIT - 2X4 LADDER FRAMING AT 12 INCHES O.C. GABLE END TRUSS rl-11 SIC>IM4-1 PEry `S Ira FJ cl 0 0114- At I 16 D COMMON NAILS AT 12" O.C. STRAP GABLE -END TRUSS WITIi -SDaWN" HETA20 AT 48" O.C. WITH (9) -10d X 1 W NAILS EMBED STRAP IN BEAM 4" / NOTE: PROVIDE RAKE BEAM AT REINFORCE EACH VERTICAL VAULTED GABLE M]ISMmEIR OF GABLE END TRUSS WITH 2 X 4 T BRACE WITH 16 D NAILS AT 8 INCHES O.C. PLAN VIEW T-BRACE GABLE END DETAIL o�... r «A" � I SAVE i SAVE �r�rr��Ic Sic I "A - ROM SHEATHING SHEATHING NAMING ZONE nts..ZONE nts... "A" = 5 FEET (TYNC4L GENANCROOF PLAN "PL4N VIEW') ZONE ROOF SHEATHING ATTACHMENT REQUIREMENTS T NAILS AT 6" O.C. PERIMETER AND 6" O.C. FIELD 0 NAILS AT 6" O.C. PERIMETER AND 6" O.C. FIELD NAILS AT 4" O.C. PERIMETER AND 6" O.C. FIELD NOTE: ROOF SHEATHING SHALL BE 19/32" THICK CDX PLYWOOD ROOF SHEATHING FASTENED TO ROOF FRAMING WITH 8d RING -SHANK NAILS (PER FRC803.2.3.1) SPACED PER ZONE DESIGNATIONS AS SHONW ABOVE. 5V METAL, V2)-c>v;' ovtlt'300 rDOFIIJL1 FEI,'i OW I9 f q2 `",%C -- PL`�(W D17b ICo�i � ��-IeArI I lbJsa �s►�� �� Sd e►u�as}{avK- HAII.-s PEA ,�ETCIL ref- eE-b � sPr��l►Jca) IvdAJUXIvu i'L.E �(,11NF.t�► WDc7fj-frtuh�S J� 51I.1Pso1J s ie4P PI:.Q.'fevss —` GDIJAJ(✓'IOL SLIIGbIII-� A'r O, G - (Mt►�G �P4C+�IG1 eAP 4 M so IJ S�P% ��h5 GDNUEL�iDR.-� t; I + #5 REB.�R W.' 00 DEGREE HOOK . ME-fA1, b9IF CUA15- a 2x (v?-,r vuool� rp�4IA, #%eEgb��r' Ci.G PER = i PL C T 1,101 VGU16D'�DFFI<F969 -t1-WA-j&4 ut?lV,�S wjal.t-5 cElurJt� e 8"X8"X16" C01-1TENUOUS CONC. PJ N I(o I{,J(Jt7Ll �i GONL, a 8��� S"tC 1�®' L � g{-OCZ- BEAM BLOCi�v. 0 ) - =5 BA-R IN Gam 6Lz4,IL w/61) (3000 PSI) CONC Fi I €D CELL 1w �GoNL• Fue-t�a1-L --8" PRECAS LINTEL kV, (:lo=5 CHAR BuP�.(,ds�'i L-1►J'fEL ��['I�#t �j �' �J �7Q� �i �( Ihl ijfX701,51, IN (3000 PSI) CONC. FILLED CFLL c.ONL• F'i" "> CE AT ALL DOOR AND VVENDOW" �iAP� Ihl �?,ODOPyI) oOIJL• igF.E ��� Pt.AN Gr�e OPENINGS (SEE LINTEL SCH FOR FiI. �liD CELL &AsJ/Air A I- Z L4�A'(ION S� • >� vh)I rJbouv OP�I+JW h chEE- MORE INFORMATION'1 ' u�l'%L S,'14eWL . FO1: NDZf- INr-0emA.-fIaQ VoUfAR P--AZ(-Y-- 8" X 8" X 16" CONC. BLOCK No FIN1-_44 COLUMN ';V/ (2) #5 BARS AVERT. �� , FOIV iJ�U1-tl I I01.j o IN (3000 PSI) CONC. FILLED CELL I 2 rI r-e4 JL'I Af ib" De ,� / I -- — STUCCO FINISH 5/8" THICK Z�' �. O `- � �t �Fp .,FL-1L4, #5 REBAR W! 30" MITI L.AP SPLICE FwpeIKJ(a 64 Goij fa&Lfo2 two cow, FaUld Db,%oll pLA N 5 toe- 41 ZE•5 4 Mc- I r 14,Ao(IOut. (2500 PSI) CONC. FOUND.=.TION �lit ! 1 �1 ' f��-�, SEE PLAN FOR SIZES AT: D 4 a i!,` )i! SPECIFICATIONS 1 V— �_{_ =�/ I j t !t ISHED GRADE ���-���.It��l�j2 r�►�c . NGi #�T m�y1Ve v'VAII r o i SECTION nts... � f � �rr��/S�cl �D ►rrr6 TYPICAL COLUMN SEC � � ,(�-�.� � C�� (a) COVERED PORCH 15 BAR X 6" MIN. EMBEDMENT INTO ING WALL DRILLED OUT AND E110XIED :6TING WALL @ 24" Q.C. VERTI( AL OM TOP AND BOTTOM) 114CVV #5 VERT. BAR & FILLED CELL ..,,-EXISTING NEW WALL -WALL t PLAN VIEW _ I TYPICAL STARTEK COLU M Nnts- y � �t rtll SLOPE TOP TOWARD EXTERIOR +/- 0.25/12 8"X8" CONTINUOUS BEAM BLOCK W/ (1) - #5 BAR VERTICAL IN (3000 PSI) CONCRETE FILLED CELLS #5 BAR VERT IN (3000 PSI) CONCRETE FILLED CELLS AT 6'-0" O.C. MAX & AT EA. END #5 BAR WITH 30" MIN.' LAP SPLICE 8" CMU WALL W/ STUCCO FINISH BOTH SIDES FNDN PER PLANS I TYPICAL KNEEWALL DETAIL NTS... WATERPBO-OFIN� � NOTE& i PRIOR TO BUCK INSTALLATION TREAT THE MASONRY OPEN11'4G WiTh A CMU WATER RESISTANT COATING TO SEAL THE WINDOW / DOOR CAVITY TO PREVENT IT FROM ABSORBING WATER. THE CMU WATER RESISTANT COATING SHALL BE APPLIED IN ACCORDANCE WITH 'THE MANUFACTURER'S RECOMMENDATIONS. THE APPLICATION OF THE CMU WATER RESiTANT COATING SHALL INCLUDE THE ENTIRE SURROUND OF THE OPENING (SILLS, .IAMBS, HEAD) AND RETURN WALLS OF THE OPENING 24" MINIMUM EACH DIRECTION, ALL CMU WATER RESISTANT COATINGS SHALL BE INSTALLED PRIOR TO BUCK iNST.ALI_ATIOINS. 2. INSTALL, BUCKS SO THAT THERE ARE NO EDGE GAPS EXCEEDING 1;8" BETWEEN BUCK .AND MASONRY. 3 PRIOR TO BUCK INSTALLATION APPLY 3/8" NOMINAL DIAMETER BEAD OF SEALANT BETWEEN THE BUCK AND THE MASONRY TO PREVENT THE PASSAGE OF LIQUID BEHIND THE BUCK. COMPLETELY SEAL THE ENTIRE END OF THE WOOD BUCKS WITH SEALANT TO RESTRICT THE PASSAGE OF LIQUID THROUGH THE CU1 ENDS .AND THE ENTIRE EXTERIOR FACE AND RETURN SURFACE OF THE BUCK SHA.i_i.. BE COATED WITH A LIQUID APPLIED WATER RESISTIVE COATING SEALANT. 4 PROVIDE PAN FLASHING AT SILL OF WINDOW AND "DOOR OPENINGS. PAN FLASHING SHALL BE SEALED OR SLOPED IN A MANNER To DIRECT WATER 'To THE SURFACE OF THE EXTERIOR WATER, RESISTIVE BARRIER FOR SUBSEQUENT DRAINAGE, INCORPORATE PAN FLASHING AT HEAD .AND SILL AS WELL. PLAN FLASHING SHALL BE CORROSION RESISTANT. 5. PROVIDE CONTINUOUS 3/8" BEAD OF SEALANT ON WINDOW / DOOR FRAMES Al ALL PERIMETER. ON FRONT .AND BACK SURFACE PRIOR TO WINDOW DOOR INSTALLATION. 6. AFTER WINDOW/ DOOR INSTALLATION PROVIDE FOAM SEALANT BETWEEN 'THE BUCK (OR PRECAST SILL) AND THE WINDOW DOOR TO ENSURE A WATER RESISTANT INTERIOR AIR SEAL AROUND THE EN i1RE PERIMETER. CMU WATER RESISTANT COATII (SEE WATERPROOFING NOTE #' CORROSION RESISTANT FLASHI PER WATERPROOFING NOTE #2 APPLY PERIMETER SEALANT C, BETWEEN BUCK & WINDOW FIR (SEE WATERPROOFING NOTE #; FILLED CELL. AT JAMB BLOCK (TYP) 1x3 P.T. WOOD FIRRING ALL (.3) SIDES CONIIN1,100 SEE WATER PROOFING NOTE #6 ANCHOR 1x4 P.T. (MIN.) BUCK WITH SEALANT PER WATERPROOFING NOTE #4 AND ANCHORED TO MASONRY WITH 1—X" CASE HARDENED COIL NAILS 012" O.C. MAX. ANCHOR WINDOW FRAME TO MASONRY IN STRICT ACCORDANCE WITH MANUFACTURE'S PRODUCT APPROVAL INSTALLATION REQUIREMENTS. WINDOW FRAME SHOULD BE COMPLETLY SE? LED ON THE BUCK. IN NO INSTANCE SHALL TIME FRAME OVERHANG THE BUCK WINDOW HEADER ANJA%3B __ 'P._BU K...l�3 TAIL SCALE N.T S. CMU WATER RESISTANT COATIN( (SEE WATERPROOFING NOTE #1) FILLED CELL AT JAMB BLOCK JYP) tx3 P.T. WOOD FIRRING .ALL (3) SIDES a ° CONTINUOUS WOOD TRIM CORROSION RESISTANT FLASHING PER WATERPROOFING NOTE #2 1x6 P.T. OBOOK WITH SEALANT PER WATERPROOFING NOTE #4 AND ANCHORED TO MASONRY wf 1—Y," CASE HARDENED COIL APPLY PERIMETER SEALANT CAULK ---/ NAILS 412" O.C. MAX. BETWEEN BUCK & WINDOW FRAME (SEE WATERPROOFING NOTE #5) SEE WATERPROOFING NOTE #fi ANCHOR DOOR JAMB HEADER TO MASONRY IN STRICT ACCORDANCE WITH MANUFACTURE'S PRODUCT APPROVAL INSTALLATION REQUIRLMENTS. EXTERIOR _DOOR _-BUCK DETAIL.__-._-T— _.. .......... ... SCALE. IN T S CONFINUUU5 FOAM INTERK)R . IR Ai•1D 'd4vTEf' SEA'i-P I PLN lVA;En::k,;�;rlj - MARBLE SILL Y," DRYWALL FASTENERS AS REk)(1iRED B'Y' WINDOW MANUFACTL!RER CORROSION RESISTANT FLASHING PLR WATERPROOFING NOTE #2 CAULK SEAM AT WINDOW INST.ALL.ATION (SEL WATERPROOFING NOTE #5) CMU WATER RESISTANT COATING (SEE vjt TERPR00,FIN(C NO i L #i SET Si', UI1. MORTAR BED 6" OMU 44" FURRING TO MASONRY WALL PRECAST CONCRETE WIND RESISTANT FLUSH SILL. AS MANUF.A(:TURERC• BY CAST—ORETE 71_ _ (OR EQUAL) .PRECAST CONCRETE V1/WDQW _ SILL ._DETAIL —--�— SCALE. N.T.S. 7 -I /- H 11u q �, M A" r C \ - F-u i•S"i' PAUL WELCH INC. KIIECHANICAL * ELECTRICAL * CIVIL ENGINEERING 1984 S.W. SIL-TMoRE ST. SUITE# 1 14 PORT SAINT LUCIE, FL 34984 PHONE EMAIL (772) 785- 9888 PWELCHINC@AOL.CO1`( PAUL WELCH P.E. FL. REG. NO. 29945 DEC ® 3 201b PORT SAINT LUCIE, FL 34984 a I �� OF TRUSS CONNECTOR SCHEDULE TRUSS ID BEARING POINT TRUSS ACTUAL CONNECTOR CONNECTOR FASTENERS NOTES UPLIFT ID UPLIFT DESIGN A 1ST 593 (1) -HETA 20 1810 (9)-10d X 1 1/2" A 2ND 465 (1)-MTSM16 860 _ (4)4/4" X 13/4" TITEN & (7)-10d GEA CONT. 224 pif ( ) HETA 20 1810 (9)-10d X 11/2" 1 STRAP AT EACH END AND AT 24" O.C. VALLEYS CONT. 100 # PLF ( ) MTS 16 1000 (14)-10d X 1 1/2" 10 1 STRAP AT EACH END AND AT 24" O.C. TRUSS COMPANY CHAMBERS LAYOUT DATE 11 4 2015 CUT -SHEET DATE 11 4 2015 NOTE: ALL STRAPPING TO BE SIMPSON STRONG -TIE AS SPECIFIED. (1) VALLEY TRUSSES MAY BE ATTACHED WITH SIMPSON VTCR W/ (4)- #9 SD X 2 1/2" TO SUPPORTING TRUSS AND (3)- #9 SD X 1 1/2" TO VALLEY TRUSS IN LIEU OF MTS16 AS STATED. VTCR SHALL BE INSTALLED AT EACH END AND 24" O.C. MAX. TRUSS NOTES: 1) ALL ROOF TRUSSES TO BE DESIGNED BY TRUSS COMPANY'S ENGINEER. 2) CONTRACTOR TO PROVIDE PAUL WELCH INC., AND BUILDING DEPARTMENT WITH ENGINEERED TRUSS DRAWINGS BEFORE INSTALLING TRUSSES. 3) CONTRACTOR TO VERIFY ALL EXISTING ROOF CONDITIONS, AND DIMENSIONS BEFORE ORDERING, AND INSTALLING TRUSSES. 4) TRUSS TO TRUSS CONNECTIONS TO BE PROVIDED BY TRUSS COMPANY. 5) SEE TRUSS CONNECTOR SCH. FOR TRUSS TO WALL CONNECTIONS. PANEL FASTENER: #9-15 X 1 'V2" WOODSCREW, HEX -HEAD W/ NEOPRENE WASHER IN THE FLAT OF THE PANEL, 3/16" MINIMUM PENETRATION THROUGH THE PLYWOOD. ALL FASTENERS TO BE CORROSION RESISTANT. FASTENERS SHALL BE INSTALLED WITH SCREWS SPACED PER BELOW: ZONE 1, 2, &3 : SCREW SPACING 24" O.C. AND 6" O.C. ACROSS PANEL AT PANEL ENDS ROOFING ATTACHMENT nts... PER FL# 7271.4 DP: -120.9 METAL ROOF PANELS SHALL BE SECURED TO THE SUPPORTS IN ACCORDANCE WITH THE APPROVED MANUFACTURER'S FASTENERS. METAL PANELS SHALL BE ATTACHED PER MANUFACTURER'S SPECIFICATIONS AND DETAIL THIS SHEET. UNDERLAYMENT SHALL BE INSTALLED AS PER MANUFACTURER'S INSTALLATION GUIDELINES UNDERLAYMENT SHALL BE APPROVED 30# ROOFING FELT. UNDERLAYMENT APPLICATION. UNDERLAYMENT SHALL BE ONE LAYER APPLIED IN THE FOLLOWING MANNER. UNDERLAYMENT SHALL BE APPLIED PARALLEL TO AND STARTING FROM THE EAVE AND LAPPED 2 INCHES (51 MM), FASTENED SUFFICIENTLY TO HOLD IN PLACE. DISTORTIONS IN THE UNDERLAYMENT SHALL NOT INTERFERE WITH ROOF PANNEL INSTALLATION. FLASHING SHALL BE INSTALLED IN SUCH A MANNER SO AS TO PREVENT MOISTURE ENTERING THE WALL AND ROOF THROUGH JOINTS IN COPINGS, THROUGH MOISTURE -PERMEABLE MATERIALS AND AT INTERSECTIONS WITH PARAPET WALLS AND OTHER PENETRATIONS THROUGH THE ROOF PLANE. ALL FLASHING SHALL BE IN ACCORDANCE WITH FLORIDA BUILDING CODE FLASHING SHALL BE INSTALLED AT WALL AND ROOF INTERSECTIONS, AT GUTTERS, WHEREVER THERE IS A CHANGE IN ROOF SLOPE OR DIRECTION AND AROUND ROOF OPENINGS. WHERE FLASHING IS OF METAL, THE METAL SHALL BE CORROSION RESISTANT WITH A THICKNESS NOT LESS THAN PROVIDED IN FBC TABLE 1503.2. THIS REQUIREMENT DOES NOT APPLY TO HIP AND RIDGE JUNCTIONS. I t7� ��. 1A' r� QY I CL c", 31 IN12 f�a�/ o v"v r 51 S-2 Awvc,K 4 of f' ALL ROOFING INSTALLATIONS SHALL BE IN ACCORANNCE WITH FL# 7271.4 AND FBC 2014. �OUQ I ll:��,Cll"_ 0<- (�� w r I/., , , , , -At "" / ELECTRICAL LOAD CALC'S 4 PER NEC INCLUDES EXISTING AND ADDITION 2008 S.F. @ 3 VA i TWO 20A APPLIANCE CKTS LAUNDRY DRYER RANGE W H t DW ►' REFRIG t IRR. PUMP (OPTION) MISC 4 TOTAL FIRST 10 KW @ 100% REMAINDER a 40% TOTAL r A/C FEAT Cal 100% TOTAL 34369.6 240 - 143 AMPS USF 150 AMP SERVICE ELECTRICAL NOTES 1) ALL ELECTRICAL WORK SHAL BE IN ACCORDANCE WITH THE NEC (NFPA 70) 2011 EDITION. 6024 VA 2) A MINIMUM OF 75% OF THE LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL BE HIGH-EFFACY LAMPS OR A MINIMUM OF 75% OF THE 3000 PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL CONTAIN ONLY 1500 HIGH-EFFACY LAMPS. (LOW VOLTAGE LIGHTING SHALL NOT BE REQUIRED 5000 TO BE HIGH-EFFACY LAMPS) 12000 3) RECESSED LIGHTING SHALL BE SEALED TO LIMIT AIR LEAKAGE BETWEEN 4500 CONDITIONED AND UNCONDITIONED SPACES. 1200 4) SMOKE DETECTORS TO BE I10V W/ BATTERY BACK UP - ARC FAULT CIRCUIT 1200 5) SMOKE DETECTORS TO BE LOCATED AS SHOWN, AND INSIDE AND OUTSIDE OF 1500 ALL EXISTING BEDROOM INTERIOR DOORS (NOT SHOWN) IF NOT EXISTING 5000 VERIFY. 40924 VA 6) SMOKE DETECTORS TO BE INTERCONNECTED SO THAT ONE SMOKE DETECTOR ACTIVATES ALL SMOKE DETECTORS IN THE RESIDENCE 10000 7) PROVIDE BRANCH CIRCUIT ARC -FAULT PROTECTION FOR ALL CIRCUITS 12369.6 SERVING: FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, OR SIMILAR ROOMS PER FBC AND NEC REQUIREMENTS. 22369.6 8) PROVIDE GROUND -FAULT CIRCUIT INTERRUPTER PROTECTION FOR ALL 125- VOLT, SINGLE-PHASE 15 AND 20 AMP CIRCUITS SEEVING: BATHROOMS, 12000 GARAGES, KITCHENS, ACCESORY BUILDINGS, OUTDOORS, OR WITHIN 72" OF EDGE OF ANY SINK. 34369.6 VA 9) CARBON MENOXIDE DETECTORS TO BE INSTALLED WITHIN 10' OF ALI, BEDROOMS. 10) PROVIDE TAMPER RESISTANT RECPTICLES PER NEC REQUIREMENTS. L-oi_L-1 too N �o TIAW pL c w P Z'L GGt:WJI7�t�/r� CaQ�� FOUI IDATION SCHEDULE F-1 16"D X 16"W (2500 PSI) CONC. MONOLITHIC FOOTING W/ (2) #5 BARS CONTINUOUS F-2 8" X 8" (2500 PSI) CONC. MONOLITHIC FOOTING W/ (2) #5 BAR CONTINUOUS F-3 23" X 16"D (2500 PSI) CONC. MONOLITHIC FOOTING W/ (2) #5 BAR CONTINUOUS P-1 24" X 24" X 24"D (2500 PSI) CONCRETE PAD FOOTING W/ #5 BARS @ 8" O.C. BOTH WAYS S-1. 4" THK (2500 PSI) CONCRETE SLAB W/ FIBERMESH OR 6"/6" 10/10 WWM OVER MCI VAPOR BARRIER ON CLEAN COMPACTED CHEMICALLY TREATED SOIL S-2 �/ 4"THK (2500 PSI) CONCRETE SLAB W/ FIBERMESH OR 6"/6" 10/10 WWM OVER EXISTING CONCRETE B-1 #5 BARS X 12" LONG DRILLED OUT & EPDXIED W/ 6" MINIMUM EMBED. @, ALL AREAS ADJACENT TO EXISTING FOUNDATION r M h., b r TT� i� DEC 0 3 20115 PAUL WELCH WC. MWHANICAL * EEIL..ECTItWCAL * C1IYlL E 1694111MI&ING I SO4 S.W. BILMRORE ST. SUrM# 114 PORT SAINT LUC1E, FL 34984 PHONE EMAIL fTl PAiJL WM C' i P.E. FL- ftG No 289d8 OM L7