HomeMy WebLinkAboutRevisions; Energy Efficiency CodeFORM R405-2014
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: BUSH RESIDENCE ADDITION
Builder Name:
Street: 11122 ORANGE AVENUE
Permit Office:
City, State, Zip: FT. PIERCE, FL,
Permit Number:
Owner:
Jurisdiction:
Design Location: FL, Fort Pierce
County:: ST. LUCIE COUNTY (Florida Climate Zone 2 )
1. New construction or existing Addition
9. Wall Types (684.0 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1 684.00 ft2
b. NIA
R= ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms(Bedrms In Addition) 0(0)
d. N/A
R= ft2
10. Ceiling Types (340.0 sqft.)
Insulation Area
5. Is this a worst case? No
a. Under Attic (Vented)
R=30.0 340.00 ft2
6. Conditioned floor area above grade (ft2) 340
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
11. Ducts
R= ft2
R ft2
7. Windows(113.3 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Attic
6 68
a. U-Factor: Dbl, U=0.65 113.33 ft2
SHGC: SHGC=0.25
b. U-Factor: N/A ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
34.4 SEER:21.50
c. U-Factor: N/A ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. 6-Factor: N/A ft2
a. Electric Strip Heat
27.0 COP:1.00
SHGC:
Area Weighted Average Overhang Depth: 4.541 ft.
Area Weighted Average SHGC: 0.250
14. Hot water systems - None required
a.
Cap: N/A
8. Floor Types (340.0 sqft.) Insulation Area
EF: 0.000
a. Slab -On -Grade Edge Insulation R=0.0 340.00 ft2
b. Conservation features
b. N/A R= ft2
c. N/A R= ft2
15. Credits
CF, Pstat
Glass/Floor Area: 0.333 Total Proposed Modifi
_ oa b 1 .5 � ArP
TM /A ccTotal
f1�7r7
Baseline
a ' 144 �I
�
q < y I Yxj ? 1 rA
I hereby certify that the plans and specifications covered by
Rf t lads an I,
TSB S74?'F
this calculation are in compliance with the Florida Energy
Code.
ecationlh ov'r [i'' t
nv
w _ O
�i�y�loritl'ai�'e�
��',•':',•4�,ti
o
Before is
r,�,���"�-- o
PREPARED BY. _
If
construction completed
for
DATE:
this building will be inspected
compliance with Section 553.908
* °
I hereby certify that this ui in designed, is in compliance
Energy
Florida Statutes.
rl, 5�
COD
with the Florida
4V'C
OWNER/ E
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as
certified factory -sealed in accordance with R403.2.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in. accordance with R402.4.1.1 and an envelope leakage
test report in accordance with R402.4.1.2. R E-V
JAN 0 5 2017
12/14/2016 1:02 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software
Page 1of 4
Fr1RhA Rdn1;-gniA
PROJECT
Title:
Building Type:
Owner:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
BUSH RESIDENCE ADDITIO Bedrooms: 0
User Conditioned Area: 340
Total Stories: 1
1 Worst Case: No
Rotate Angle: 0
Cross Ventilation:
Whole House Fan:
Single-family
Addition
Address Type:
Lot #
Block/SubDivision:
PlatBook:
Street:
County:
City, State, Zip:
Street Address
11122 ORANGE AVEN
ST. LUCIE COUNTY
FT. PIERCE,
FL,
CLIMATE
Design Location
IECC Design Temp
TMY Site Zone 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, Fort Pierce FL VERO_BEACH_MUNI 2 39, 90
70 75 299
62 Low
BLOCKS
Number
Name
Area Volume
1
Block1
340 3060
SPACES
,
Number
Name
Area Volume Kitchen Occupants
Bedrooms InfilID Finished Cooled Heated
1
Main
340 3060 Yes 1
1 Yes
Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 76 ft 0
340 ft2 ---
0 0 1
ROOF
#
Type
Roof Gable Roof
Materials Area Area Color
Solar SA Emitt
Absor. Tested
Emitt Deck Pitch
Tested Insul. (deg)
1
Gable or shed
Metal 368 ft2 70 ft2 Light
0.6 No 0.9
No 0 22.6
ATTIC
V #
Type
Ventilation Vent Ratio (1 in)
Area RBS IRCC
1
Full attic
Vented 150
340 ft2 N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
Under Attic (Vented)
Main 30 Blown 340 ft2 0.11
Wood
12/14/2016 1:02 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 4
FORM R405-2014
1�2_
WALLS
/
Adjacent
Cavity Width Height Sheathing Framing Solar
Below
�#�rnt
�►
To alLType Space R-Vatue Ft In Ft In Area R-Value_F-ValueAbsor Grade.
_ 1 S
Exterior Concrete Block - Ext Insul Main
4.1 24 9 216.0 ft2 0
0 0.6
0
2 W
Exterior Concrete Block - Ext Insul Main
4.1 14 9 126.0 ft2 0
0 0.6
0
_ 3 N
Exterior Concrete Block - Ext Insul Main
4.1 24 9 216.0 ft2 0
0 0.6
0
4 E
Exterior Concrete Block - Ext Insul Main
4.1 14 9 126.0 ft2 0
0 0.6
0
WINDOWS
Orientation shown is the entered, Proposed orientation.
/
Wall
Overhang
v #
Omt ID Frame Panes NFRC
U-Factor SHGC Area Depth Separation
Int Shade
Screening
1
S 1 Metal Low-E Double Yes
0.65 0.25 48.0 ft2 8 ft 0 in 1 ft4 in
Drapes/blinds
None
2
S 1 Metal Low-E Double Yes
0.65 0.25 20.0 ft2 2 ft 0 in 1 ft 4 in
Drapes/blinds
None
3
S 1 Metal Low-E Double Yes
0.65 0.25 13.3 ft2 2 ft 0 in 1 ft4 in
Drapes/blinds
None
4
W 2 Metal Low-E Double Yes
0.65 0.25 12.0 ft2 2 ft 0 in 1 ft 4 in
Drapes/blinds
None
5
E 4 Metal Low-E Double Yes
0.65 0.25 20.0 ft2 2 ft 0 in 1 ft 4 in
Drapes/blinds
None
INFILTRATION
# Scope
Method SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .0004
357 19.6 36.86 .2922
7
HEATING SYSTEM
#
System Type Subtype
Efficiency Capacity
Block
Ducts
1
Electric Strip Heat None
COPA 27 kBtu/hr
1
sys#1
COOLING SYSTEM
#
System Type Subtype
Efficiency Capacity Air Flow
SHR Block
Ducts
1
Central Unit None
SEER: 21.5 34.4 kBtu/hr 1032 cfm
0.8 1
sys#1
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert # Company Name
System Model # Collector Model # Area
Volume
FEF
ft2
DUCTS
- Supply - - Return -- Air CFM 25 CFM25
HVAC #
#
Location R-Value Area Location
Area Leakage Type Handler TOT OUT
QN RLF
Heat Cool
1
Attic 6 68 ft2 Attic
17 111:2 Default Leakage Attic (Default) (Default)
1 1
12/14/2016 1:02 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 4
FORM R405-2014
TEMPERATURES
Programable[ Thermostat: Y
Ceiling Fans:
Heating [X] Jan
Feb
ki
Mar
W
Apr
Apr
May
Jun
ri
Jdl
Jul
ri Au
Aug
ri
Sep
ct
w O
Nov
Nov
H Dec
DecVenting
[[ II Jan
Feb
Mar
X�
Thermostat Schedule:
HERS 2006
Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
12/14/2016 1:02 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 4
l
FORM R405-2014
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: BUSH RESIDENCE ADDITION Builder Name:
Street: 11122 ORANGE AVENUE Permit Office:
City, State, Zip: FT. PIERCE, FL, Permit Number:
Owner. Jurisdiction:
Design Location: FL, Fort Pierce
COMPONENT
CRITERIA
CHECK
Air barrier and thermal barrier
A continuous air barrier shall be installed in the building envelope.
Exterior thermal envelope contains a continuous barrier.
Breaks or joints in the air barrier shall be sealed.
Air -permeable insulation shall not be used as a sealing material.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with the
insulation and any gaps in the air barrier shall be sealed.
Access openings, drop down stairs or knee wall doors to unconditioned
attic spaces shall be sealed.
Comers and headers shall be insulated and the junction of the foundation
Walls
and sill plate shall be sealed.
The junction of the top plate and the top or exterior walls shall be sealed.
Exterior thermal envelope insulation for framed walls shall be installed in
substantial contact and continuous alignment with the air barrier.
Knee walls shall be sealed.
Windows, skylights and doors
The space between window/door jambs and framing and skylights and
framing shall be sealed.
Rim joists
Rim joists are insulated and include an air barrier.
Floors (including above -garage
Insulation shall be installed to maintain permanent contact with underside
and cantilevered floors)
of subfloor decking.
The air barrier shall be installed at any exposed edge of insulation.
Crawl space walls
Where provided in lieu of floor insulation, insulation shall be permanently
attached to the crawlspace walls. '
Exposed earth in unvented crawl spaces shall be covered with a Class I
vapor retarder with overlapping joints taped.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shaft openings to exterior or
unconditioned space shall be sealed.
Narrow cavities
Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled
by insulation that on installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope shall be
air tight, IC rated, and sealed to the drywall.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring and plumbing in
exterior walls, or insulation that on installation readily conforms to available
space shall extend behind piping and wiring.
Shower/tub on exterior wall
Exterior walls adjacent to showers and tubs shall be insulated and the air
barrier installed separating them from the showers and tubs.
Electrical/phone box on
The air barrier shall be installed behind electrical or communication boxes or
air sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub -floor or drywall.
Fireplace
An air barrier shall be installed on fireplace walls. Fireplaces shall have
gasketed doors
12/14/2016 1:02 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1
FORM R405-2014
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 83
The lower the EnergyPerformance Index, the more efficient the home.
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ft2)
7. Windows—
Description
a. U-Factor:
Dbl, U=0.65
SHGC:
SHGC=0.25
b. U-Factor:
N/A
SHGC:
c. U-Factor:
WA
SHGC:
d. U-Factor:
WA
SHGC:
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
11122 ORANGE AVENUE, FT. PIERCE, FL,
Addition
Single-family
1
0(0)
No
340
Area
113.33 ft2
ft2
ft2
ft2
8. Floor Types Insulation
a. Slab -On -Grade Edge Insulation R=0.0
4.541 ft.
0.250
Area
340.00 ft2
2
9. Wall Types
a. Concrete Block - Ext Insul, Exterior
b. N/A
c. N/A
d. N/A
10. Ceiling Types
a. Under Attic (Vented)
b. N/A
c. N/A
11. Ducts
a. Sup: Attic, Ret: Attic, AH: Attic
12. Cooling systems
a. Central Unit
13. Heating systems
a. Electric Strip Heat
14. Hot water systems - None required
a.
b. N/A R- ft
c. N/A R= ft2 b. re
15. Cr �
I certify that this home has complied with the Florida Energy Efficiency ode di
Construction through the above energy saving features which will be installed (or exceeded)
in this home before fin i s e ton. Otherwise, a new EPL Display Card will be completed
based on installed Co o lia t feature .
Builder Signature: Date: `� J
Address of New Homer 2`L () {r- Ikk City/FL Zip:
Insulation Area
R=4.1 684.00 ft2
R=
ft2
R=
ft2
R=
ft2
Insulation
Area
R=30.0
340.00 ft2
R=
ft2
R=
ft2
R ft2
6 68
kBtu/hr Efficiency
34.4 SEER:21.50
kBtu/hr Efficiency
27.0 COP:1.00
Cap: WA
EF:
Pstat
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support
staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Fnt atif
COP
12/14/2016 1:02 PM EnergyGauge® USA - FlaRes2014 - Section R405.4.1 Compliant Software Page 1 of 1