Loading...
HomeMy WebLinkAboutRevisions; Energy Efficiency CodeFORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: BUSH RESIDENCE ADDITION Builder Name: Street: 11122 ORANGE AVENUE Permit Office: City, State, Zip: FT. PIERCE, FL, Permit Number: Owner: Jurisdiction: Design Location: FL, Fort Pierce County:: ST. LUCIE COUNTY (Florida Climate Zone 2 ) 1. New construction or existing Addition 9. Wall Types (684.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 684.00 ft2 b. NIA R= ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms(Bedrms In Addition) 0(0) d. N/A R= ft2 10. Ceiling Types (340.0 sqft.) Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=30.0 340.00 ft2 6. Conditioned floor area above grade (ft2) 340 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A 11. Ducts R= ft2 R ft2 7. Windows(113.3 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 68 a. U-Factor: Dbl, U=0.65 113.33 ft2 SHGC: SHGC=0.25 b. U-Factor: N/A ft2 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 34.4 SEER:21.50 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. 6-Factor: N/A ft2 a. Electric Strip Heat 27.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 4.541 ft. Area Weighted Average SHGC: 0.250 14. Hot water systems - None required a. Cap: N/A 8. Floor Types (340.0 sqft.) Insulation Area EF: 0.000 a. Slab -On -Grade Edge Insulation R=0.0 340.00 ft2 b. Conservation features b. N/A R= ft2 c. N/A R= ft2 15. Credits CF, Pstat Glass/Floor Area: 0.333 Total Proposed Modifi _ oa b 1 .5 � ArP TM /A ccTotal f1�7r7 Baseline a ' 144 �I � q < y I Yxj ? 1 rA I hereby certify that the plans and specifications covered by Rf t lads an I, TSB S74?'F this calculation are in compliance with the Florida Energy Code. ecationlh ov'r [i'' t nv w _ O �i�y�loritl'ai�'e� ��',•':',•4�,ti o Before is r,�,���"�-- o PREPARED BY. _ If construction completed for DATE: this building will be inspected compliance with Section 553.908 * ° I hereby certify that this ui in designed, is in compliance Energy Florida Statutes. rl, 5� COD with the Florida 4V'C OWNER/ E BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as certified factory -sealed in accordance with R403.2.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in. accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. R E-V JAN 0 5 2017 12/14/2016 1:02 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1of 4 Fr1RhA Rdn1;-gniA PROJECT Title: Building Type: Owner: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: BUSH RESIDENCE ADDITIO Bedrooms: 0 User Conditioned Area: 340 Total Stories: 1 1 Worst Case: No Rotate Angle: 0 Cross Ventilation: Whole House Fan: Single-family Addition Address Type: Lot # Block/SubDivision: PlatBook: Street: County: City, State, Zip: Street Address 11122 ORANGE AVEN ST. LUCIE COUNTY FT. PIERCE, FL, CLIMATE Design Location IECC Design Temp TMY Site Zone 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 2 39, 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Block1 340 3060 SPACES , Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 340 3060 Yes 1 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 76 ft 0 340 ft2 --- 0 0 1 ROOF # Type Roof Gable Roof Materials Area Area Color Solar SA Emitt Absor. Tested Emitt Deck Pitch Tested Insul. (deg) 1 Gable or shed Metal 368 ft2 70 ft2 Light 0.6 No 0.9 No 0 22.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 340 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) Main 30 Blown 340 ft2 0.11 Wood 12/14/2016 1:02 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 4 FORM R405-2014 1�2_ WALLS / Adjacent Cavity Width Height Sheathing Framing Solar Below �#�rnt �► To alLType Space R-Vatue Ft In Ft In Area R-Value_F-ValueAbsor Grade. _ 1 S Exterior Concrete Block - Ext Insul Main 4.1 24 9 216.0 ft2 0 0 0.6 0 2 W Exterior Concrete Block - Ext Insul Main 4.1 14 9 126.0 ft2 0 0 0.6 0 _ 3 N Exterior Concrete Block - Ext Insul Main 4.1 24 9 216.0 ft2 0 0 0.6 0 4 E Exterior Concrete Block - Ext Insul Main 4.1 14 9 126.0 ft2 0 0 0.6 0 WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang v # Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 S 1 Metal Low-E Double Yes 0.65 0.25 48.0 ft2 8 ft 0 in 1 ft4 in Drapes/blinds None 2 S 1 Metal Low-E Double Yes 0.65 0.25 20.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds None 3 S 1 Metal Low-E Double Yes 0.65 0.25 13.3 ft2 2 ft 0 in 1 ft4 in Drapes/blinds None 4 W 2 Metal Low-E Double Yes 0.65 0.25 12.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds None 5 E 4 Metal Low-E Double Yes 0.65 0.25 20.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds None INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .0004 357 19.6 36.86 .2922 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat None COPA 27 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit None SEER: 21.5 34.4 kBtu/hr 1032 cfm 0.8 1 sys#1 SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF ft2 DUCTS - Supply - - Return -- Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 68 ft2 Attic 17 111:2 Default Leakage Attic (Default) (Default) 1 1 12/14/2016 1:02 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 4 FORM R405-2014 TEMPERATURES Programable[ Thermostat: Y Ceiling Fans: Heating [X] Jan Feb ki Mar W Apr Apr May Jun ri Jdl Jul ri Au Aug ri Sep ct w O Nov Nov H Dec DecVenting [[ II Jan Feb Mar X� Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 12/14/2016 1:02 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 4 l FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: BUSH RESIDENCE ADDITION Builder Name: Street: 11122 ORANGE AVENUE Permit Office: City, State, Zip: FT. PIERCE, FL, Permit Number: Owner. Jurisdiction: Design Location: FL, Fort Pierce COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air -permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Comers and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/door jambs and framing and skylights and framing shall be sealed. Rim joists Rim joists are insulated and include an air barrier. Floors (including above -garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawlspace walls. ' Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight, IC rated, and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors 12/14/2016 1:02 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 83 The lower the EnergyPerformance Index, the more efficient the home. 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft2) 7. Windows— Description a. U-Factor: Dbl, U=0.65 SHGC: SHGC=0.25 b. U-Factor: N/A SHGC: c. U-Factor: WA SHGC: d. U-Factor: WA SHGC: Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 11122 ORANGE AVENUE, FT. PIERCE, FL, Addition Single-family 1 0(0) No 340 Area 113.33 ft2 ft2 ft2 ft2 8. Floor Types Insulation a. Slab -On -Grade Edge Insulation R=0.0 4.541 ft. 0.250 Area 340.00 ft2 2 9. Wall Types a. Concrete Block - Ext Insul, Exterior b. N/A c. N/A d. N/A 10. Ceiling Types a. Under Attic (Vented) b. N/A c. N/A 11. Ducts a. Sup: Attic, Ret: Attic, AH: Attic 12. Cooling systems a. Central Unit 13. Heating systems a. Electric Strip Heat 14. Hot water systems - None required a. b. N/A R- ft c. N/A R= ft2 b. re 15. Cr � I certify that this home has complied with the Florida Energy Efficiency ode di Construction through the above energy saving features which will be installed (or exceeded) in this home before fin i s e ton. Otherwise, a new EPL Display Card will be completed based on installed Co o lia t feature . Builder Signature: Date: `� J Address of New Homer 2`L () {r- Ikk City/FL Zip: Insulation Area R=4.1 684.00 ft2 R= ft2 R= ft2 R= ft2 Insulation Area R=30.0 340.00 ft2 R= ft2 R= ft2 R ft2 6 68 kBtu/hr Efficiency 34.4 SEER:21.50 kBtu/hr Efficiency 27.0 COP:1.00 Cap: WA EF: Pstat *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Fnt atif COP 12/14/2016 1:02 PM EnergyGauge® USA - FlaRes2014 - Section R405.4.1 Compliant Software Page 1 of 1