HomeMy WebLinkAboutEnergy Efficiency CodeFORM R405-2014
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
4 Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: BUSH RESIDENCE ADDITION
Builder Name:
Street: 11122 ORANGE AVE.
Permit Office:
City, State, Zip: FT. PIERCE, FL,
Permit Number:
Owner:
Jurisdiction:
Design Location: FL, Fort Pierce
County:: ST. LUCIE COUNTY (Florida Climate Zone 2 )
1. New construction or existing Addition
9. Wall Types (684.0 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1 684.00 ft2
b. N/A
R= ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms(Bedrms In Addition) 0(0)
d. N/A
R= ft2
10. Ceiling Types (340.0 sqft.)
Insulation Area
5. Is this a worst case? No
a. Under Attic (Vented)
R=30.0 340.00 ft2
6. Conditioned floor area above grade (ft2) 340
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
11. Ducts
R ft2
7. Windows(117.4 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Attic
6 68
a. U-Factor: Sgl, U=0.65 113.33 ft2
SHGC: SHGC=0.25
b. U-Factor: Dbl, U=0.42 4.08 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.21
a. Central Unit
34.4 SEER:21.50
c. U-Factor: N/A ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Strip Heat
27.0 COPA.00
SHGC:
Area Weighted Average Overhang Depth: 4.541 ft.
Area Weighted Average SHGC: 0.249
14. Hot water systems - None required
a.
Cap: N/A
8. Floor Types (340.0 sqft.) Insulation Area
EF: 0.000
a. Slab -On -Grade Edge Insulation R=0.0 340.00 ft2
b. Conservation features
b. N/A R= ft2
c. N/A R= ft2
15. Credits
CF, Pstat
Glass/Floor Area: 0.345 Total Proposed Modified Loads: 13.36
PASS
Total Baseline Loads: 14.99
1 hereby certify that the plans and specifications covered by
Review of the plans and
kv. TIE ST.q?�
this calculation are in pliance with the Florida Energy
specifications covered by this
,� r • '
Off,
Code.
calculation indicates compliance
.�ti. ;_
nr
with the Florida Energy Code.
PREPA D
Before construction is completed
94 "-l�'��I; a
DATE: �-
this building will be inspected for
0 +�
compliance with Section 553.908
I hereby certify that this building, as a igned, is in compliance
Florida Statutes.
COD
with the Florida Energy
WE
L/
C,�WNER/A E. T:
BUILDING OFFICIAL:
DATE: G '
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.2.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R 1.10 d c0aneYkage
test report in accordance with R402.4.1.2.
8/9/2016 9:50 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4
FORM R405-2014
PROJECT
Title:
"Building Type:
Owner:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
BUSH RESIDENCE ADDITIO Bedrooms: 0
User Conditioned Area: 340
Total Stories: 1
1 Worst Case: No
Rotate Angle: 0
Cross Ventilation:
Whole House Fan:
Single-family
Addition
Address Type: Street Address
Lot #
Block/SubDivision:
PlatBook:
Street: 11122 ORANGE AVE.
County: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE,
FL,
CLIMATE
Design Location
IECC Design Temp
TMY Site Zone 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, Fort Pierce FL VERO_BEACH_MUNI 2 39 90
70 75 299 62 Low
BLOCKS
Number
Name
Area Volume
1
Block1
340 3060
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms InfilID Finished Cooled Heated
1
ADDITION
340 3060 No 2
1 Yes Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio ADDITION 76 ft 0
340 ft2 ---- 1 0 0
ROOF
V #
Type
Roof Gable Roof
Materials Area Area Color
Solar SA Emitt Emitt Deck Pitch
Absor. Tested Tested Insul. (deg)
1
Hip
Metal 368 ft2 0 ft2 Light
0.6 No 0.9 No 0 22.6
ATTIC
V #
Type
Ventilation Vent Ratio (1 in)
Area RBS IRCC
1
Full attic
Vented 300
340 ft2 N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
Under Attic (Vented)
ADDITION 30 Blown 340 ft2 0.11 Wood
8/9/2016 9:50 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 4
FORM R405-2014
WALLS
Adjacent Cavity Width Height
Sheathing Framing Solar
Below
is
rnt
To wai, Type Spate R-value Ft In Et In
Area
R-yatue_Eraion-Absor^Grade°!o-
1
S
Exterior Concrete Block - Ext InsLADDITION 4.0999 24 9
216.0 ft2
0
0 0.75
0
2
W
Exterior Concrete Block - Ext InsLADDITION 4.0999 14 9
126.0 ft2
0
0 0.75
0
3
N
Exterior Concrete Block - Ext InsLADDITION 4.0999 24 9
216.0 ft2
0
0 0.75
0
4
E
Exterior Concrete Block - Ext InsLADDITION 4.0999 14 9
126.0 ft2
0
0 0.75
0
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall
Overhang
v
#
Omt ID Frame Panes NFRC U-Factor SHGC Area
Depth
Separation
Int Shade
Screening
1
S 1 Metal Low-E Single Yes 0.65 0.25 48.0 ft2
8 ft 0 in
1 ft 4 in
Drapes/blinds
None
2
S 1 Metal Low-E Single Yes 0.65 0.25 20.0 ft2
2 ft 0 in
1 ft 4 in
Drapes/blinds
None
3
S 1 Metal Low-E Single Yes 0.65 0.25 13.3 ft2
2 ft 0 in
1 ft 4 in
Drapes/blinds
None
4
W 2 Metal Low-E Single Yes 0.65 0.25 12.0 ft2
2 ft 0 in
1 ft 4 in
Drapes/blinds
None
5
S 1 Metal Low-E Single Yes 0.65 0.25 20.0 ft2
2 ft 0 in
1 ft 4 in
Drapes/blinds
None
6
S Skylt Metal Low-E Double Yes 0.42 0.21 1.4 ft2
0 ft 0 in
0 ft 0 in
Drapes/blinds
None
7
S Skylt Metal Low-E Double Yes 0.42 0.21 1.4 ft2
0 ft 0 in
0 ft 0 in
Drapes/blinds
None
8
S Skylt Metal Low-E Double Yes 0.42 0.21 1.4 ft2
0 ft 0 in
0 ft 0 in
Drapes/blinds
None
INFILTRATION
#
Scope
Method SLA CFM 50 ELA EgLA
ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000286 255 14 26.33
.2087
5
HEATING SYSTEM
#
System Type Subtype Efficiency Capacity
Block
Ducts
1
Electric Strip Heat None COPA 27 kBtu/hr
1
sys#1
COOLING SYSTEM
#
System Type Subtype Efficiency Capacity Air Flow
SHR Block
Ducts
1
Central Unit None SEER: 21.534.4 kBtu/hr 1032 cfm
0.8 1
sys#1
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert # Company Name System Model # Collector Model #
Area
Volume FEF
ft2
8/9/2016 9:50 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 4
Ff1RM Rdn--gniA
DUCTS
— Supply
—
-- Return —
Air
CFM 25
CFM25
HVAC #
V # Location R-Value
Area
Location
Area
Leakage Type
Handler
TOT
OUT
QN
RLF
Heat Cool
1
Attic 6
68 ftZ
Attic
17 ft2
Default Leakage
Attic
(Default) (Default)
1 1
TEMPERATURES
Programable Thermosta[[t:]]Y
Ceiling Fans:
Jan
[X] Feb
[[ jj
(X] Mar
Apr
Apr I
Me
I May
un
ri J
[Xj
[ ] Jul
Aug
$ep
IXI
[ jHeatng
L.1
Oct
Oct
�Xi Nov
Nov
H Dec
DecVenting
Jan
[[ ]] Feb
[[X]] Mar
Jun
[ j Jul
Aug
Sep
lxJ
Thermostat Schedule:
HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
8/9/2016 9:50 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 4