HomeMy WebLinkAboutDUCT DRAWINGJob #: 1641
Performed by Chris Bateman for:
Key Largo Spec
6000 Cassia Dr
Ft. Pierce, FL 34982
Air Calcs, LLC
7550 Hidden Hammock Ln
Vero Beach, FL 32966
Phone: 772.800.8413
vickilynne@aircalcs.com
Scale: 1 : 120
Page 1
Right-Suite® Universal 2021
21.0.08 RSU29066
2021-Oct-13 09:50:16
...HVAC\6000 Cassia Dr PSL Prop.rup
N
Level 1
Garage
Laundry
Bed 2
Bath Bath 2Hall
Bed 3Bed 4
Foyer GR
Pantry
Kitchen DR
Master Bath
WIC
Master Bed
H/W
DUCTS IN THE GARAGE AND
DUCTS PENETRATING THE
WALLS OR CEILINGS
SEPARATING THE DWELLING
FROM
THE GARAGE SHALL BE
CONSTRUCTED OF A MINIMUM
NO.
26 GAGE (0.48 MM) SHEET
STEEL, 1 INCH MINIMUM RIGID
NONMETALLIC CLASS 0 OR
CLASS 1 DUCT BOARD, OR
OTHER APPROVED MATERIAL
AND SHALL HAVE NO
OPENINGS INTO THE GARAGE
100 CFM
6" Duct
6"Exhaust Vent
50 CFM
4" Duct
4"Exhaust Vent
50 CFM
4" Duct
4"Exhaust Vent
12 x 12
135 cfm
12 x 12
174 cfm
10 x 10
168 cfm
12 x 12
131 cfm
10 x 10
168 cfm
10 x 10
193 cfm 10 x 10
193 cfm
30 x 18
862 cfm
12 x 8
135 cfm
12 x 8
174 cfm
8 x 8
52 cfm
8 x 8
3 cfm
8 x 4
42 cfm
12 x 8
131 cfm
6 "
10 "
7 "
4 "
8 "
7 "
4 "
7 "
7 "
7 "7 "
6 "
7 "
12 "
14 "
18 "
F
F
F
9 "
4 "
8 x 8
102 cfm 6 "
8 x 8
102 cfm
6 "
8 x 4
22 cfm
8 x 8
114 cfm
7 "
14 x 14
225 cfm
14 x 14
12 "