HomeMy WebLinkAboutBOUNDARY PLOT PLANFDOH in St. Lucie County
Environmental Health
Site Plan Approved for Construction
Supercedes All Previous Site Plans for
OSTDS #
Well #
Date: Reviewer:
LEGEND:
(C) = CALCULATED
(D) = DEED
(M) = MEASURED
(P) = PLATTED
CMP = CORRUGATED METAL PIPE
CNS = COULD NOT SET
CONC = CONCRETE
FEE = FINISHED FLOOR ELEVATION
FND = FOUND
IR = 5/8" IRON REBER
IRC = S/8" IRON REBAR WITH PLASTIC CAP
PCOR = PROPERTY CORNER
PCP = PERMANENT CONTROL POINT
PL = PROPERTY LINE
PUDE = PUBLIC UTILITIES AND DRAINAGE EASEMENT
R/W = RIGHT-OF-WAY
R = RADIUS OF CURVE
L = LENGTH OF CURVE
SF = SQUARE FOOT
o = DELTA OF CURVE
0 = SET 5/8" IRON REBAR WITH PLASTIC
CAP "AJP PSM 6330"
x=� 00
x00
¢' 0)
_ LJO
t3
z ZQ
(o ¢z
LLJ
a
W O
cn �
II
J
w
16� 30.00'
rY�
�U
ON
00
1-41-4
0000
v
0 ,
o .'
1 FND IRC
"LB 6790"
ir] o
O
Lo ifi
N N
FND IRC
"LB 2391 "
14.30 5'
5'
jV
LOD
5' 5' ZIe
hti
Z
�� POWER
POLE
15.83
30.00' W
T IR
SEIR
FND
wAT> R
METER
S
0.5 2'S,
0.15'W
C IL
-o
V�O
00
CO ao
0) O]
FND IR
3.0N,
2.6'W
LOT 5 BLOCK 86 oW
F NO WELL
0
S/T
x 6' CLF CORNER
/"-4.6'N OF PL
28.92'
5' �
3.00'
w
pO
(DOZ
CO crLd
4' n
U<(n00
N
O_J
LLJ
mYo II
9.33'
LLjLLJ
~
z
H LJ
O p 0_
Jp0
:20-
50.50'
N PROPOSED
1" WATER SERVICE
rn
FND IRC
15.90
58.75'
r-�
N
F-
O
J
iECTION OF
4 CLF
3.6'N,
OF PCOR
4' CLF CORNER
0.3'W OF PL
=x—x—
rvr
Va
00
0000
W
CV
43.50' O
N C)
rJ V)
15.79
S89057' 23"W 125.00'
TBD CASSIA DRIVE
ICDMPLFTFD
YPE OF SURVEY: BOUNDARY PLOT PLAN U C TIE IN FINAL TOPOGRAPHIC
ONI: 10-�28-21 11-09-21
LOT 7 BLOCK 86
FFE = 18.72
NO WELL
ALEXANDER J. PIAZZA PSM, INC.
Surwying • Mapping • Consulting
619 SW Biltmore Street
® Port St. Lucie, Florida 34983
Phone: (772) 340-7770
DATE: RE1/190NS: ay. LBj72aO Fax: (772) 340-2250
N
O
J
F-
N Z
(0 O
�Y
NOZ
0
�J
07J
O �
0
J
wa
Ca„
z
aQ
o
J
N N W
S/T
O �c]YzC)
NO00
� mOz
O
LAST FIELD DATE: 10-26-21
K:\eUILDERS\0M2021\21-8211.DWG
REF K.\
FLO BF/DG
OFF LW/AJP
CKD AJP
F8. PG.
SHEET 1 OF 1
Jos 21-0211
DATE 11-09 21
DING C-1455
z0
� ll
C1-j
t3
c�
LEGAL DESCRIPTION:
LOT 6 IN BLOCK 86 OF INDIAN RIVER ESTATES UNIT 9,
ACCORDING TO THE PLAT THEREOF AS RECORDED IN PLAT BOOK
10, PAGE 74, OF THE PUBLIC RECORDS OF ST. LUCIE
COUNTY, FLORIDA.
SURVEY NOTES:
1. THIS IS A BOUNDARY SURVEY AS DEFINED IN CHAPTER
5J-17.050(11), FLORIDA ADMINISTRATIVE CODE.
2. UNLESS OTHERWISE NOTED ONLY PLATTED EASEMENTS ARE
SHOWN HEREON.
3. NO UNDERGROUND UTILITIES OR IMPROVEMENTS WERE
LOCATED UNLESS OTHERWISE SHOWN.
4. THIS SITE LIES WITHIN FLOOD ZONE "X", ACCORDING TO
THE FLOOD INSURANCE RATE MAP, COMMUNITY PANEL NO.
12111CO281 K, EFFECTIVE DATE FEBRUARY 19, 2020_
5. FLOOD ZONE SHOWN HEREON IS AN INTERPRETATION BY THE
SURVEYOR AND IS PROVIDED AS A COURTESY. THE FLOOD
ZONE SHOULD BF VERIFIED BY A DETERMINATION AGENCY.
6. BEARINGS SHOWN HEREON ARE BASED ON THE EAST LINE
OF LOT 6 ASSUMED TO BEAR S00'02'37"E
7. ALL LOT DIMENSIONS SHOWN ARE PER PLAT UNLESS
OTHERWISE NOTED. ALL SURVEY MEASUREMENTS ARE IN
FFET.
8. ALL MAPPED FEATURES SHOWN HEREON ARE UNDER THE
DIRECT SUPERVISION AND RESPONSIBILITY OF ALEXANDER
J. PIAZZA PSM, INC.
9. SURVEY MAP AND REPORT OR THE COPIES THEREOF ARE NOT
VALID WITHOUT THE ORIGINAL SIGNATURE AND SEAL OF A
FLORIDA LICENSED SURVEYOR AND MAPPER.
10.ADDITIONS OR DELETIONS TO THE SURVEY MAP OR REPORT
BY OTHER THAN THE SIGNING PARTY OR PARTIES IS
PROHIBITED WITHOUT THE WRITTEN CONSENT OF THE
SIGNING PARTY OR PARTIES.
11.ADD ITIONS OR DELETIONS TO THE SURVEY MAP OR REPORT
BY OTHER THAN THE SIGNING PARTY OR PARTIES IS
PROHIBITED WITHOUT CONSENT OF THE SIGNING PARTY OR
PARTIES.
CERTIFIED TO:
PORT ST LUCIE PROPERTIES, INC.
ALd ANDf� J -
Professional- Sucveyof"'& Mapper
Florida Certificate No.: 6330
K:\BUILDERS\DWG2021\21-8211.dwg, 11/9/2021 11:59:37 AM