HomeMy WebLinkAboutCertification For Design Load CompliancePlanning & Development Services Department
Building & Code Regulations Division
2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553
RECEIVED
Certification for Design Load Compliance OCT Q 8 2020
Project Name: 8007 Hibiscus Rd ,.4We k3ountv
erm tt ng
Project Address: 8007 Hibiscus Rd, Fort Pierce, FL 34951
Permit #: Occupancy Type: R-3 Construction Type: VB
INSTRUCTIONS FOR USE:
• This certification must be completed, signed, and sealed by the design professional of record.
• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or multi -family)
o Residential Addition
o Any accessory structure requiring a building permit
o Any non-residential structure.
* Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida BUILDING Code Sixth Edition with 20 20 Supplements using ASCE 7-10
2. Structure Designed as (check one): X Enclosed Partially Enclosed Open
3. Risk Category: I X II III IV Exposure Category: B X C D
4. Design Wind Velocity 160 mph X ASD LRFD End Zone Width: 6 ft
5. Mean Roof Height 15 ft Roof Pitch: 4 :12 Parapet: NSA ft
6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings):
Zone 1: 53.3 Zone 2: 70.4 Zone 3: 95.9 Zone 4: 33.2 Zone 5: 40.9 Garage:
7. Design Loads: Floor: NSA PSF Roof/Dead: 20 PSF Roof/Live: 20 Balcony: NSA PSF
Dock: NSA PSF Deck: NSA PSF Stairs: NSA PSF Fence: NSA PSF Railings: NSA PSF
8. Were Shear Walls Considered For Structure? X Yes Not Applicable Explain Why Not:
9. Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? Yes
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
County. I also certify that structural elements depicted on these plans provide adequate resistance to the design
forcessl QRdit iC��I�tii.rt�i�����
♦♦�``�1�.... 1%ei.q ys;% Ryan M Bays
. CEN
Print Name Cert # & Co. Cert Auth.
r ABe _'OR I
lR
Whole House Engineering
4451 St Lucie Blvd Suite 201, Fort Pierce, FL 34946
Company Name & Address