HomeMy WebLinkAboutEnergy Efficiency CodeFORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTMJCTION Florida Department of Business and Professional Regulation - Residential Per rrOW7 Method Project Name: 8007 Hibiscus Road Energygauge Builder Name: ' Habitat for -Humanity'- ""''e Uounty Street: 8007 Hibiscus Road Permit Office: Permitting City, State, Zip: Ft. Pierce, FL, Permit Number:_ Owner: Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie(Florida Climate Zone 2) 1. New construction or existing 2. Single family or multiple:family 3. Number of units, if multiple family 4. Number of Bedrooms New (From Plans) Detached 1 5. Is this a worst case? 6. Conditioned floor area above grade (ft2) Conditioned floor area below grade (ft2) 7. Windows(85.9 sqft.) Description a. U-Factor: Dbl, U=0.66 SHGC: SHGC=0.25 b. U-Factor: N/A SHGC: c. U-Factor: N/A SHGC: Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 8. Skylights Description U-Factor:(AVG) N/A SHGC(AVG): N/A 9. Floor Types Insulation 'a. Slab -On -Grade Edge Insulation R= 0.0 b. N/A R= c. N/A R= Glass/Floor Area: 0.064 3 No 1335 0 Area 85.94 ft2 ft2 ft2 1.500 ft , 0.250 Area N/A ft2 Area 1334.80 ft2 ft2 ft2 10. Wall Types(1320.0. sqft.) Insulation Area a.. Concrete Block - Int Insul, Exterior R=4.1 1092.00 ft2 b. Concrete Block - Int Insul, AdjacenR=4.1 228.00 ft2 c. N/A R=- ft2 d. N/A R= f{2 11. Ceiling Types(1337.0 sqft.) Insulation Area a. Under Attic (Vented) R=3b.0 1337.00 ft2 b. N/A R= ft2 c. N/A R= ft2 12. Ducts, location & insulation level R ft2 a. a. Sup: Attic, Ret: Attic_ , AH: Attic 6 267 b. C. 13. Cooling Systems kBtu/hr Efficiency a. Central Unit 27.6 SEER:16.00 14. Heating Systems - kBtu/hr Efficiency a. Electric Strip Heat. 27.3 COP:1.00 15. Hot Water Systems a. Electric Cap: 40 gallons EF: 0.950 b. Conservation features None 16. Credits CF, CV, Total Proposed Modified Loads: 42.34 Total Baseline Loads: 42.35 S hereby certify that the plans and specifications covered by Review of the plans and this. calculation are in compliance with the Florida Energy - specifications covered by this QF CHE STg2� Code. / calculation indicates compliance' with the Florida Energy Code. PREPARED BY: Before construction is completed this building will be inspected for DATE: June 2, 2�2� compliance with Section 553.908 Florida Statutes. hereby certify ridathat this il building, as designed, is in compliance with COD WE v9� OWNER/AGENT: BUILDING OFFICIAL: DATE: 1. 01 -A z, DATE: - toompuance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance with a proposed duct leakage Qn requires a PERFORMANCE Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.000 Qn for whole house. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires a PERFORMANCE envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 6/2/2021 4:45:07 PM EnergyGaugeO USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: 8007 Hibiscus Road Energygauge Address type: Street Address Building Type: User Bedrooms: 3 Lot #: - Owner: Conditioned Area: 1335 Block/SubDivision: - Total Stories: 1 PlatBook: - Builder Name: Habitat for Humanity Worst Case: No Street: 8007 Hibiscus Road Permit Office: Rotate Angle: 0 County: St. Lucie Jurisdiction: Cross Ventilation: Yes City, State, Zip: Ft. Pierce, Family Type: Detached Whole House Fan: No FL, New/Existing: New (From Plans) Terrain: Suburban Year Construct: Shielding: Suburban Comment: CLIMATE Design Design Temp Int Design Temp Heating Design Daily temp Location Tmy Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH MUNICIPA 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1335 10680 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Finished Cooled' Heated _ 1 Bed 2 197 1576 No 1 1 Yes Yes Yes -2 clst 2 21 168 No 0 Yes Yes Yes -3 Bath 2 117 936 No 0 Yes Yes Yes _ 4 Bed 3 191 1528 No 1 1 Yes Yes Yes , _ 5 clst 3 18 144 No 0 Yes Yes Yes _ 6 Kit Din LR 497 3976 Yes 0 Yes Yes Yes _ 7 pnty 21 168 No 0 Yes Yes Yes _ 8 Bed 1 175 1400 No 2 1 Yes Yes Yes _ 9 clst 1 18 144 No 0 Yes Yes Yes _ 10 Bath 1 80 640 No 0 Yes Yes Yes FLOORS (Total Exposed Area = 1335 sq.ft.) # Floor Type Space Exposed Perim Perimeter R-Value Area U-Factor Joist R-Value Tile Wood Carpet _ 1 Slab -On -Grade Edge Ins Bed 2 33 196.5 ft 0.710 - 1.00 0.00 0.00 -2 Slab -On -Grade Edge Ins clst 2 3 21 ft 0.710 - 1.00 0.00 0.00 -3 Slab -On -Grade Edge Ins Bath 2 9 117 ft 0.710 - 1.00 0.00 0.00 _ 4 Slab -On -Grade Edge Ins Bed 3 26.5 190.5 ft 0.710 - 1.00 0.00 0.00 _ 5 Slab -On -Grade Edge Ins clst 3 2.5 17.5 ft 0.710 - 1.00 0.00 0.00 _ 6 Slab -On -Grade Edge Ins Kit Din LR 42 497 ft 0.710 - 1.00 0.00 0.00 _ 7 Slab -On -Grade Edge Ins pnty 2.5 21.3 ft 0.710 - 1.00 0.00 0.00 _ 8 Slab -On -Grade Edge Ins Bed 1 26.5 175 ft 0.710 - 1.00 0.00 0.00 _ 9 Slab -On -Grade Edge Ins clst 1 2.5 . 17.5 ft 0.710 - 1.00 0.00 0.00 _ 10 Slab -On -Grade Edge Ins Bath 1 17.5 81.5 ft 0.710 - 1.00 0.00 0.00 6/2/2021 4:45:08 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT ROOF , / Roof Gable Area Area Roof Color Rad Solar SA Emitt Emitt Barr Absor. Tested Tested Deck Pitch Insul. (deg) V # Type Materials 1 ' Gable or Shed Composition shingles 1407 ft2 222 ft2 Medium N 0.9 No 0.9 No 0 18.43 ATTIC # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 1335 ft2 N N CEILING (Total Exposed Area = 1337 sq.ft.) # Ceiling Type Space R-Value Ins. Type Area U-Factor Framing Frac. Truss Type 1 Under Attic(Vented) Bed 2 30.0 Blown 197.0ft2 0.053 0.10 Wood _ Under Attic(Vented) clst 2 30.0 Blown 21.0ft2 0.053 0.10 Wood -2 Under Attic(Vented) Bath 2 30.0 Blown 117.0ft2 0.053 0.10. Wood -3 4 Under Attic(Vented) Bed 3 30.0 Blown 191.0ft2 0.053 0.10 Wood _ 5 Under Attic(Vented) clst 3 30.0 Blown 18.0ft2 0.053 0.10 Wood _ Under Attic(Vented) Kit Din LR 30.0 Blown 497.Oft2 0.053 0.10 Wood -6 7 Under Attic(Vented) pnty 30.0 Blown 21.0ft2 0.053 0.10 Wood _ 8 Under Attic(Vented) Bed 1 30.0 Blown 175.0ft2 0.053 0.10 Wood _ 9 Under Attic(Vented) cast 1 30.0 Blown 18.0ft2 0.053 0.10 Wood _ 10 Under Attic(Vented) Bath 1 30.0 Blown 82.0ft2 0.053 0.10 Wood WALLS (Total Exposed Area = 1320 sq.ft.) Adjacent Cavity Width Height Area U- Sheath Frm. Solar Below ✓# Omt To Wall Type Space R-Value Ft In Ft In sq.ft. Factor R-Value Frac. Absor. Grade N Exterior Conc. Blk - Int Ins Bed 2 4.1 13.0 6 8.0 0 108.0 0.149 0 0 0.40 0 % -1 E Exterior Conc. Blk - Int Ins Bed 2 4.1 13.0 6 8.0 0 108.0 0.149 0 0 0.40 0 % -2 W Exterior Conc. Blk - Int Ins Bed 2 4.1 6.0 0 8.0 0 48.0 0.149 0 0 0.40 0 % -3 4 E Exterior Conc. Blk - Int Ins clst 2 4.1 3.0 0 8.0 0 24.0 0.149 0 0 0.40 0 % _ 5 E Exterior Conc. Blk - Int Ins Bath 2 4.1 9.0 0 8.0 0 72.0 0.149 0 0 0.40 0 % _ E Exterior Conc. Blk - Int Ins Bed 3 4.1 13.0 6 8.0 0 108.0 0.149 0 0 0.40 0 % -6 7 S Exterior Conc. Blk - Int Ins Bed 3 4.1 13.0 0 8.0 0 104.0 0.149 0 0 0.40 0 % _ 8 E Exterior Conc. Blk - Int Ins clst 3 4.1 2.0 6 8.0 0 20.0 0.149 0 0 0.40 0 % _ 9 S Exterior Conc. Blk - Int Ins Kit Din LR 4.1 13.0 6 8.0 0 108.0 0.149 0 0 0.40 0 % _ 10 N Exterior Conc. Blk - Int Ins Kit Din LR 4.1 14.0 0 8.0 0 112.0 0.149 0 0 0.40 0 % _ 11 W Garage Conc. Blk - Int Ins Kit Din LR 4.1 14.0 6 8.0 0 116.0 0.149 0 0 0.40 0 % _ 12 S Exterior Conc. Blk - Int Ins pnty 4.1 2.0 6 8.0 0 20.0 0.149 0 0 0.40 0 % _ 13 W Exterior Conc. Blk - Int Ins Bed 1 4.1 12.0 6 8.0 0 100.0 0.149 0 0 0.40 0 % _ 14 N Garage Conc. Blk - Int Ins Bed 1 4.1 14.0 0 8.0 0 112.0 0.149 0 0 0.40 0 % _ 15 W Exterior Conc. Blk - Int Ins clst 1 4.1 2.0 6 8.0 0 20.0 0.149 0 0 0.40 0 % _ 16 S Exterior Conc. Blk - Int Ins Bath 1 4.1 11.0 6 8.0 0 92.0 0.149 0 . 0 0.40 0 % _ 17 W Exterior Conc. Blk - Int Ins Bath 1 4.1 6.0 0 8.0 0 48.0 0.149 0 0 0.40 , 0 % DOORS (Total Exposed Area = 42 sq.ft.) Width Height V # Omt Adjacent To Door Type Space Storms U-Value Ft In Ft In Area N Exterior Wood Kit Din LR None 0.39 3.00 0 7.00 0 21.0ft2 -1 2 N Exterior Wood Kit Din LR None 0.39 3.00 0 7.00 .0 21.0ft2 6/2/2021 4:45:08 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WINDOWS (Total Exposed Area = 86 sq.ft.) Wall -Overhang- # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Storm Area Depth Separation Interior Shade Screening 1 N 1 None Double (Clear) Yes 0.66 0.25 Y N 18.7ft2 1.0 ft 6 in 1.0 ft 0 in Drapes/blinds Exterior 50% _ S 7 None Double (Clear) Yes 0.66 0.25 Y N 16.9ft' 1.0 ft 6 in 1.0 ft 0 in Drapes/blinds Exterior 50% -2 S 9 None Double (Clear) Yes 0.66 0.25 Y N 24.0ft' 1.0 ft 6 in 1.0 ft 0 in Drapes/blinds Exterior 50% -3 4 N 10 None Double (Clear) Yes 0.66 0.25 Y N 10.02 1.0 ft 6 in 1.0 ft 0 in Drapes/blinds Exterior 50% _ 5 W 13 None Double (Clear) Yes 0.66 0.25 Y N 16.4ft2 1.0 ft 6 in 1.0 ft 0 in Drapes/blinds Exterior 50% INFILTRATION # Scope Method SLA CFM50 ELA EgLA ACH ACH50 Space(s) 1 Wholehouse Proposed ACH(50) 0.00036 1246 68.36 128.34 0.1263 7.0 All GARAGE # Floor Area Roof Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 383 ft2 383 ft2 64 ft 8 ft 1 MASS # Mass Type Area Thickness Furniture Fraction Space 1 Default(8 Ibs/sq.ft.) 0 ft2 O ft 0.30 Bed 2 _ Default(8 Ibs/sq.ft.) 0 ft2 O ft 0.30 clst 2 -2 Default(8 Ibs/sq.ft.) 0 ft2 O ft 0.30 Bath 2 -3 4 Default(8 Ibs/sq.ft.) 0 ft2 O ft 0.30 Bed 3 _ 5 Default(8 Ibs/sq.ft.) 0 ft2 O ft 0.30 clst 3 _ Default(8 Ibs/sq.ft.) 0 ft2 0 ft 0.30 Kit Din LR -6 7 Default(8 Ibs/sq.ft.) 0 ft2 0 ft 0.30 pnty _ 8 Default(8 Ibs/sq.ft.) 0 ft2 O ft 0.30 Bed 1 _ 9 Default(8 Ibs/sq.ft.) 0 ft2 O ft 0.30 clst 1 _ 10 Default(8 Ibs/sq.ft.) 0 ft2 0 ft 0.30 Bath 1 HEATING SYSTEM # System Type Subtype AHRI # Efficiency Capacity --Geothermal HeatPump-- Ducts Block kBtu/hr Entry Power Volt Current 1 Electric Strip Heat None COP: 1.00 27.3 0.00 0.00 0.00 sys#1 1 COOLING SYSTEM # System Type Subtype/Speed AHRI # Efficiency Capacity Air Flow SHR Duct Block kBtu/hr cfm 1 Central Unit SplittSingle SEER:16.0 27.6 0 0.74 sys#1 1 6/2/2021 4:45:08 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT HOT WATER SYSTEM # System Type Subtype Location EF(UEF) Cap Use SetPnt Fixture Flow Pipe Ins. Pipe length 1 Electric None Garage 0.95 (0.93) 40.00 gal 61 gal 120 deg Standard None 83 Recirculation Recirc Control Loop Branch Pump DWHR Facilities Equal DWHR Other Credits System Type length length power Connected Flow Eff 1 No NA NA NA No NA NA NA None DUCTS Duct ----Supply--- -----Return---- Air CFM 25 CFM 25 HVAC # # Location R-Value Area Location R-Value Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6.0 267 ft2 Attic 6.0 67 ft2 Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: N Ceiling Fans: N Cooling [ ] Jan [ ] Feb, [ ] Mar [ ] Apr [ ] May [X] Jun [X] Jul [X] Aug [X] Sep [ ] Oct [ ] Nov (I Dec Heating [X] Jan [X] Feb [X] Mar [ ] Apr [ ] May [ ] Jun [ ] Jul [ ] Aug [ ] Sep [ ] Oct [X],Nov [X] Dec Venting [ ] Jan [I Feb [X] Mar [X] Apr [ ] May [ ] Jun [ ] Jul [ ] Aug [ ] Sep [X] Oct [X] Nov [ ] Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM PM 78 80 78 80 78 78 78 78 80 80 78 78 78 78 78 78 80 80 78 78 80 80 78 78 Cooling (WEH) AM PM 78 80 78 80 78 78 78 78 80 80 78 78 78 78 78 78 80 80 78 78 80 -80 78 78 _ Heating (WD) AM PM 65 68 65 68 65 65 65 65 68 68 68 68 65 68 68 68 68 68 68 68 68 68 68 68 _Heating (WEH) AM PM 65 68 65 68 65 65 65 65 68 68 68 68 -65 68 68 68 68 68 68 68 68 68 68 68 6/2/2021 4:45:08 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5