HomeMy WebLinkAboutEnergy Efficiency CodeFORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTMJCTION
Florida Department of Business and Professional Regulation - Residential Per rrOW7 Method
Project Name: 8007 Hibiscus Road Energygauge Builder Name: ' Habitat for -Humanity'- ""''e Uounty
Street: 8007 Hibiscus Road Permit Office: Permitting
City, State, Zip: Ft. Pierce, FL, Permit Number:_
Owner: Jurisdiction:
Design Location: FL, Fort Pierce County: St. Lucie(Florida Climate Zone 2)
1. New construction or existing
2. Single family or multiple:family
3. Number of units, if multiple family
4. Number of Bedrooms
New (From Plans)
Detached
1
5. Is this a worst case?
6. Conditioned floor area above grade (ft2)
Conditioned floor area below grade (ft2)
7. Windows(85.9 sqft.) Description
a. U-Factor: Dbl, U=0.66
SHGC: SHGC=0.25
b. U-Factor: N/A
SHGC:
c. U-Factor: N/A
SHGC:
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
8. Skylights Description
U-Factor:(AVG) N/A
SHGC(AVG): N/A
9. Floor Types Insulation
'a. Slab -On -Grade Edge Insulation R= 0.0
b. N/A R=
c. N/A R=
Glass/Floor Area: 0.064
3
No
1335
0
Area
85.94 ft2
ft2
ft2
1.500 ft ,
0.250
Area
N/A ft2
Area
1334.80 ft2
ft2
ft2
10. Wall Types(1320.0. sqft.)
Insulation
Area
a.. Concrete Block - Int Insul, Exterior R=4.1
1092.00 ft2
b. Concrete Block - Int Insul, AdjacenR=4.1
228.00 ft2
c. N/A
R=-
ft2
d. N/A
R=
f{2
11. Ceiling Types(1337.0 sqft.)
Insulation
Area
a. Under Attic (Vented)
R=3b.0
1337.00 ft2
b. N/A
R=
ft2
c. N/A
R=
ft2
12. Ducts, location & insulation level
R ft2
a. a. Sup: Attic, Ret: Attic_ , AH: Attic
6 267
b.
C.
13. Cooling Systems
kBtu/hr
Efficiency
a. Central Unit
27.6 SEER:16.00
14. Heating Systems - kBtu/hr Efficiency
a. Electric Strip Heat. 27.3 COP:1.00
15. Hot Water Systems
a. Electric Cap: 40 gallons
EF: 0.950
b. Conservation features
None
16. Credits CF, CV,
Total Proposed Modified Loads: 42.34
Total Baseline Loads: 42.35
S
hereby certify that the plans and specifications covered by Review of the plans and
this. calculation are in compliance with the Florida Energy - specifications covered by this QF CHE STg2�
Code. / calculation indicates compliance'
with the Florida Energy Code.
PREPARED BY: Before construction is completed
this building will be inspected for
DATE: June 2, 2�2� compliance with Section 553.908
Florida Statutes.
hereby
certify
ridathat this il building, as designed, is in compliance
with COD WE
v9�
OWNER/AGENT: BUILDING OFFICIAL:
DATE: 1. 01 -A z, DATE:
- toompuance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance with a proposed duct leakage Qn requires a PERFORMANCE Duct Leakage Test Report confirming duct
leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.000 Qn for whole house.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project
requires a PERFORMANCE envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
6/2/2021 4:45:07 PM EnergyGaugeO USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: 8007 Hibiscus Road Energygauge
Address type:
Street Address
Building Type: User
Bedrooms: 3
Lot #:
-
Owner:
Conditioned Area: 1335
Block/SubDivision: -
Total Stories: 1
PlatBook:
-
Builder Name: Habitat for Humanity
Worst Case: No
Street:
8007 Hibiscus Road
Permit Office:
Rotate Angle: 0
County:
St. Lucie
Jurisdiction:
Cross Ventilation: Yes
City, State, Zip:
Ft. Pierce,
Family Type: Detached
Whole House Fan: No
FL,
New/Existing: New (From Plans)
Terrain: Suburban
Year Construct:
Shielding: Suburban
Comment:
CLIMATE
Design
Design Temp
Int Design Temp
Heating
Design
Daily temp
Location
Tmy Site
97.5% 2.5%
Winter Summer
Degree Days
Moisture
Range
FL, Fort Pierce FL_VERO_BEACH MUNICIPA 39 90
70 75
299
62
Low
BLOCKS
Number Name
Area
Volume
1 Entire House
1335
10680
SPACES
Number Name
Area
Volume Kitchen Occupants
Bedrooms
Finished
Cooled' Heated
_ 1 Bed 2
197
1576 No 1
1
Yes
Yes
Yes
-2 clst 2
21
168 No 0
Yes
Yes
Yes
-3 Bath 2
117
936 No 0
Yes
Yes
Yes
_ 4 Bed 3
191
1528 No 1
1
Yes
Yes
Yes ,
_ 5 clst 3
18
144 No 0
Yes
Yes
Yes
_ 6 Kit Din LR
497
3976 Yes 0
Yes
Yes
Yes
_ 7 pnty
21
168 No 0
Yes
Yes
Yes
_ 8 Bed 1
175
1400 No 2
1
Yes
Yes
Yes
_ 9 clst 1
18
144 No 0
Yes
Yes
Yes
_ 10 Bath 1
80
640 No 0
Yes
Yes
Yes
FLOORS
(Total Exposed Area = 1335 sq.ft.)
# Floor Type
Space
Exposed Perim Perimeter R-Value Area U-Factor Joist R-Value
Tile Wood Carpet
_ 1 Slab -On -Grade Edge Ins
Bed 2
33
196.5 ft 0.710
-
1.00
0.00 0.00
-2 Slab -On -Grade Edge Ins
clst 2
3
21 ft 0.710
-
1.00
0.00 0.00
-3 Slab -On -Grade Edge Ins
Bath 2
9
117 ft 0.710
-
1.00
0.00 0.00
_ 4 Slab -On -Grade Edge Ins
Bed 3
26.5
190.5 ft 0.710
-
1.00
0.00 0.00
_ 5 Slab -On -Grade Edge Ins
clst 3
2.5
17.5 ft 0.710
-
1.00
0.00 0.00
_ 6 Slab -On -Grade Edge Ins
Kit Din LR
42
497 ft 0.710
-
1.00
0.00 0.00
_ 7 Slab -On -Grade Edge Ins
pnty
2.5
21.3 ft 0.710
-
1.00
0.00 0.00
_ 8 Slab -On -Grade Edge Ins
Bed 1
26.5
175 ft 0.710
-
1.00
0.00 0.00
_ 9 Slab -On -Grade Edge Ins
clst 1
2.5 .
17.5 ft 0.710
-
1.00
0.00 0.00
_ 10 Slab -On -Grade Edge Ins
Bath 1
17.5
81.5 ft 0.710
-
1.00
0.00 0.00
6/2/2021 4:45:08 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
ROOF
, /
Roof Gable
Area Area
Roof
Color
Rad Solar SA Emitt Emitt
Barr Absor. Tested Tested
Deck Pitch
Insul. (deg)
V # Type
Materials
1 ' Gable or Shed
Composition shingles 1407 ft2 222 ft2
Medium
N 0.9 No
0.9 No
0 18.43
ATTIC
# Type
Ventilation
Vent Ratio (1 in) Area
RBS
IRCC
1 Full attic
Vented
300
1335 ft2
N
N
CEILING
(Total Exposed Area = 1337 sq.ft.)
# Ceiling Type
Space
R-Value
Ins. Type
Area
U-Factor
Framing Frac.
Truss Type
1 Under Attic(Vented)
Bed 2
30.0
Blown
197.0ft2
0.053
0.10
Wood
_
Under Attic(Vented)
clst 2
30.0
Blown
21.0ft2
0.053
0.10
Wood
-2
Under Attic(Vented)
Bath 2
30.0
Blown
117.0ft2
0.053
0.10.
Wood
-3
4 Under Attic(Vented)
Bed 3
30.0
Blown
191.0ft2
0.053
0.10
Wood
_
5 Under Attic(Vented)
clst 3
30.0
Blown
18.0ft2
0.053
0.10
Wood
_
Under Attic(Vented)
Kit Din LR
30.0
Blown
497.Oft2
0.053
0.10
Wood
-6
7 Under Attic(Vented)
pnty
30.0
Blown
21.0ft2
0.053
0.10
Wood
_
8 Under Attic(Vented)
Bed 1
30.0
Blown
175.0ft2
0.053
0.10
Wood
_
9 Under Attic(Vented)
cast 1
30.0
Blown
18.0ft2
0.053
0.10
Wood
_
10 Under Attic(Vented)
Bath 1
30.0
Blown
82.0ft2
0.053
0.10
Wood
WALLS
(Total Exposed Area = 1320 sq.ft.)
Adjacent
Cavity
Width
Height
Area
U- Sheath Frm. Solar Below
✓# Omt To
Wall Type
Space
R-Value
Ft In
Ft In
sq.ft. Factor R-Value Frac. Absor. Grade
N Exterior
Conc. Blk - Int Ins
Bed 2
4.1
13.0 6
8.0 0
108.0
0.149 0 0
0.40 0 %
-1
E Exterior
Conc. Blk - Int Ins
Bed 2
4.1
13.0 6
8.0 0
108.0
0.149 0 0
0.40 0 %
-2
W Exterior
Conc. Blk - Int Ins
Bed 2
4.1
6.0 0
8.0 0
48.0
0.149 0 0
0.40 0 %
-3
4 E Exterior
Conc. Blk - Int Ins
clst 2
4.1
3.0 0
8.0 0
24.0
0.149 0 0
0.40 0 %
_
5 E Exterior
Conc. Blk - Int Ins
Bath 2
4.1
9.0 0
8.0 0
72.0
0.149 0 0
0.40 0 %
_
E Exterior
Conc. Blk - Int Ins
Bed 3
4.1
13.0 6
8.0 0
108.0
0.149 0 0
0.40 0 %
-6
7 S Exterior
Conc. Blk - Int Ins
Bed 3
4.1
13.0 0
8.0 0
104.0
0.149 0 0
0.40 0 %
_
8 E Exterior
Conc. Blk - Int Ins
clst 3
4.1
2.0 6
8.0 0
20.0
0.149 0 0
0.40 0 %
_
9 S Exterior
Conc. Blk - Int Ins
Kit Din LR
4.1
13.0 6
8.0 0
108.0
0.149 0 0
0.40 0 %
_
10 N Exterior
Conc. Blk - Int Ins
Kit Din LR
4.1
14.0 0
8.0 0
112.0
0.149 0 0
0.40 0 %
_
11 W Garage
Conc. Blk - Int Ins
Kit Din LR
4.1
14.0 6
8.0 0
116.0
0.149 0 0
0.40 0 %
_
12 S Exterior
Conc. Blk - Int Ins
pnty
4.1
2.0 6
8.0 0
20.0
0.149 0 0
0.40 0 %
_
13 W Exterior
Conc. Blk - Int Ins
Bed 1
4.1
12.0 6
8.0 0
100.0
0.149 0 0
0.40 0 %
_
14 N Garage
Conc. Blk - Int Ins
Bed 1
4.1
14.0 0
8.0 0
112.0
0.149 0 0
0.40 0 %
_
15 W Exterior
Conc. Blk - Int Ins
clst 1
4.1
2.0 6
8.0 0
20.0
0.149 0 0
0.40 0 %
_
16 S Exterior
Conc. Blk - Int Ins
Bath 1
4.1
11.0 6
8.0 0
92.0
0.149 0 . 0
0.40 0 %
_
17 W Exterior
Conc. Blk - Int Ins
Bath 1
4.1
6.0 0
8.0 0
48.0
0.149 0 0
0.40 , 0 %
DOORS
(Total Exposed Area = 42 sq.ft.)
Width Height
V # Omt Adjacent To Door Type
Space
Storms
U-Value
Ft
In Ft In
Area
N Exterior
Wood
Kit Din LR
None
0.39
3.00
0 7.00 0
21.0ft2
-1
2 N Exterior
Wood
Kit Din LR
None
0.39
3.00
0 7.00 .0
21.0ft2
6/2/2021 4:45:08 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
WINDOWS
(Total Exposed Area = 86 sq.ft.)
Wall
-Overhang-
# Ornt ID Frame
Panes
NFRC U-Factor SHGC Imp Storm Area
Depth Separation
Interior Shade Screening
1 N
1 None
Double (Clear)
Yes 0.66
0.25 Y N 18.7ft2
1.0 ft 6 in 1.0 ft 0 in
Drapes/blinds Exterior 50%
_
S
7 None
Double (Clear)
Yes 0.66
0.25 Y N 16.9ft'
1.0 ft 6 in 1.0 ft 0 in
Drapes/blinds Exterior 50%
-2
S
9 None
Double (Clear)
Yes 0.66
0.25 Y N 24.0ft'
1.0 ft 6 in 1.0 ft 0 in
Drapes/blinds Exterior 50%
-3
4 N
10 None
Double (Clear)
Yes 0.66
0.25 Y N 10.02
1.0 ft 6 in 1.0 ft 0 in
Drapes/blinds Exterior 50%
_
5 W
13 None
Double (Clear)
Yes 0.66
0.25 Y N 16.4ft2
1.0 ft 6 in 1.0 ft 0 in
Drapes/blinds Exterior 50%
INFILTRATION
# Scope Method
SLA
CFM50 ELA EgLA
ACH ACH50
Space(s)
1
Wholehouse Proposed ACH(50)
0.00036
1246 68.36 128.34
0.1263 7.0
All
GARAGE
#
Floor Area
Roof Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
383 ft2
383 ft2
64 ft
8 ft
1
MASS
#
Mass Type
Area
Thickness Furniture Fraction
Space
1
Default(8 Ibs/sq.ft.)
0 ft2
O ft
0.30
Bed 2
_
Default(8 Ibs/sq.ft.)
0 ft2
O ft
0.30
clst 2
-2
Default(8 Ibs/sq.ft.)
0 ft2
O ft
0.30
Bath 2
-3
4
Default(8 Ibs/sq.ft.)
0 ft2
O ft
0.30
Bed 3
_
5
Default(8 Ibs/sq.ft.)
0 ft2
O ft
0.30
clst 3
_
Default(8 Ibs/sq.ft.)
0 ft2
0 ft
0.30
Kit Din LR
-6
7
Default(8 Ibs/sq.ft.)
0 ft2
0 ft
0.30
pnty
_
8
Default(8 Ibs/sq.ft.)
0 ft2
O ft
0.30
Bed 1
_
9
Default(8 Ibs/sq.ft.)
0 ft2
O ft
0.30
clst 1
_
10
Default(8 Ibs/sq.ft.)
0 ft2
0 ft
0.30
Bath 1
HEATING SYSTEM
#
System Type
Subtype
AHRI # Efficiency Capacity --Geothermal HeatPump-- Ducts Block
kBtu/hr Entry Power
Volt Current
1
Electric Strip Heat
None
COP: 1.00 27.3 0.00
0.00 0.00 sys#1 1
COOLING SYSTEM
#
System Type
Subtype/Speed
AHRI # Efficiency
Capacity Air Flow SHR Duct Block
kBtu/hr cfm
1
Central Unit
SplittSingle
SEER:16.0 27.6 0
0.74 sys#1 1
6/2/2021 4:45:08 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
HOT WATER SYSTEM
# System Type
Subtype
Location
EF(UEF) Cap Use
SetPnt
Fixture Flow Pipe Ins.
Pipe length
1 Electric
None
Garage
0.95 (0.93) 40.00 gal 61 gal
120 deg
Standard None
83
Recirculation
Recirc Control
Loop Branch Pump DWHR
Facilities Equal
DWHR
Other Credits
System
Type
length length power
Connected Flow
Eff
1 No
NA NA NA No
NA
NA
NA
None
DUCTS
Duct ----Supply---
-----Return----
Air
CFM 25 CFM 25
HVAC #
# Location
R-Value Area Location
R-Value Area Leakage Type
Handler
TOT
OUT QN
RLF Heat Cool
1 Attic
6.0 267 ft2
Attic
6.0 67 ft2 Default Leakage
Attic
(Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: N
Ceiling Fans: N
Cooling [ ] Jan
[ ] Feb,
[ ] Mar
[ ] Apr
[ ] May [X] Jun [X] Jul
[X] Aug
[X] Sep
[ ] Oct [ ] Nov (I Dec
Heating [X] Jan
[X] Feb
[X] Mar
[ ] Apr
[ ] May [ ] Jun [ ] Jul
[ ] Aug
[ ] Sep
[ ] Oct [X],Nov [X] Dec
Venting [ ] Jan
[I Feb
[X] Mar
[X] Apr
[ ] May [ ] Jun [ ] Jul
[ ] Aug
[ ] Sep
[X] Oct [X] Nov [ ] Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3 4 5 6
7
8 9
10
11 12
Cooling (WD)
AM
PM
78
80
78
80
78 78 78 78
80 80 78 78
78
78
78
78
80 80
78 78
80 80
78 78
Cooling (WEH)
AM
PM
78
80
78
80
78 78 78 78
80 80 78 78
78
78
78
78
80 80
78 78
80 -80
78 78
_ Heating (WD)
AM
PM
65
68
65
68
65 65 65 65
68 68 68 68
65
68
68
68
68 68
68 68
68 68
68 68
_Heating (WEH)
AM
PM
65
68
65
68
65 65 65 65
68 68 68 68
-65
68
68
68
68 68
68 68
68 68
68 68
6/2/2021 4:45:08 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5