Loading...
HomeMy WebLinkAboutHealth SurveyBENCHMARK PNT. 20007 SET MAG/D EL:19.69' L=31.32' R=20. O' 0 89*43'00"( ) PROPOSED 500 SO. FT. DRAINFIELD 818 SQ. FT. UNOBSTRUCTED AREA 18" CMP INV.15.39 H I I B X�S 0j (70X0 1b' . Ilia I_'. r9.B a� �Ir o• C) 0 O Q PA Ch � P4 W0 DIz w C:) I �W O PIP0 ro Ncb C U S Q°R0A BLIC RIGHT!%F-WAY) �- o, x o �9 ET �o LB_8 11o' , tK N1 ,L 35.00' o oJ• �5� -x o _ 5/8" IRC '�o' r` i 91.00'(P)( 43951" O Sri N (LBgg9A U I. �o5a $Vr- Cb 34.67' 3 I° 0 w O / o IM r/y O / U) /PROP / WATER / LINE. 8" CMP 0 189046'35 4V:17.05 :*.. . 00 CC C_A. If, ro 1• O -F�qE VED S(j- 0 GRAPHIC SCALE Petri.1 30 0 15 30 Bt' pel�nl� np�� SEARING BASIS) I 1 inch = 30 & 122.66'(C) FND 356/7��5/�(C—FND MAG/D PK/D (LB7903) 0.19' N 0.2W W SET 5/8" IR , PROP. b (LB8098) 16' CONC. N DRIVE ' 14.67' 00' 13.33' AC PAD^ PROPOSED `� a RESIDENCE v FFE: * to 41.33' P 15.00, CON C.o6f r .P PORCH 8.00' T_ 21 LOT 22 �'� 0. (VOA ANT) (VACANT) x`1L1J >c 00 0 L,;0 C KZ b1 00'(P (C) 35. I- x COMM F� 18�, c oHwELE — — x SET 3�8" IRC - 9 — ' (LB8098) FND 1/2" IR D- w (NO ID) LOT 21 0 6 0.89' S (OCCUPIED) o 4 FFE:20.77' o SEPTIC BEYOND 75' 4 7 SET -5/8" TR1✓ (LB8098) .:.FND 1 /2•" IR 0.18'. E 2.14' S FDOH in St. Lucie County Environmental Health r G�P�OI�QI Site Plan Approved for Construction n� Supercedes All Previous Site`Plans for SITE PLAN NOTES.;r n r • FINISHED FLOOR TO BE DETERMINED BY SAINT LUCIE COUNTY HEALTH DEPA T. OSTDS # PUBLIC WATER WATER AND SANITARY SERVICES ARE NOT AVAILABLE W@II # f5q - 3a 3� Reviewer: . ST. LUCIE COUNTY, FLORIDA VICINITY MAP SYMBOL & ABBREVIATION LEGEND: NO SCALE ASPH ASPHALT HYDRANT P.U. do D.E.PUBLIC UTILITY AND DRAINAGE EASEMENT BENCHMARK (BM) INV INVERT (P) PLAT DATA (CYYY) CALCULATED IP IRON PIPE R RADIUS CENTERLINE IR IRON ROD R/W RIGHT-OF-WAY CLF CHAIN LINK FENCE IRC IRON ROD AND CAP 0 PROPERTY CORNER CONC CONCRETE MAG/D MAG,NAIL MAG BRAND NAIL RIGHT-OF-WAY (D) DEED CONTROL D.B. DEED BOOK MAILBOX TOPOGRAPHIC DATA EB 0 ELECTRIC BOX N.R. NON RADIAL X 0.0 (SOFT SURFACE) EL./ELEV. . ELEVATION NORTH AMERICAN X 0.00 TOPOGRAPHIC DATA (M) FIELD MEASURED NAVD88 VERTICAL DATUM OF (HARD SURFACE) 19BB WATER SERVICE METER F.F.E. FINISHED FLOOR O.R.B.OFFICIAL RECORDS 0 (WM) ELEVATIONBOOK FND FOUND OHW OVER HEAD WIRES WV N WATER VALVE (WV) SQ FT. SQUARE FEET PG PAGE GAS �Q GAS VALVE pI</p PARKER-KALON NAIL & ® MONITORING WELL DISK WF WOOD FENCE . to GUY WIRE ANCHOR P.B. PLAT BOOK LEGAL DESCRIPTION WOOD POWER POLE LOT 22, BLOCK 47 OF LAKEWOOD PARK UNIT NO. 5, ACCORDING TO THE PLAT THEREOF AS RECORDED IN PLAT BOOK 11, PAGE 5, OF THE, PUBLIC RECORDS OF ST. LUCIE COUNTY, FLORIDA: CONTAINING 0.28 ACRES;, MORE OR LESS. SURVEYORS NOTES AND REPORT: 1. NOT VALID WITHOUT THE SIGNATURE AND THE ORIGINAL RAISED SEAL OF A FLORIDA LICENSED. SURVEYOR AND MAPPER. ADDITIONS OR DELETIONS TO SURVEY MAPS OR REPORTS, BY OTHER THAN THE SIGNING SURVEYOR IS PROHIBITED, WITHOUT CONSENT OF THE SIGNING SURVEYOR. 2. THE LAST DATE OF FIELD WORK WAS JUNE 10, 2021. 3. CURRENT. DESCRIPTIONS SHOWN HEREON PROVIDED BY THE CLIENT 'AND/OR THEIR AGENTS. LANDS SHOWN HEREON WERE NOT ABSTRACTED BY THIS OFFICE FOR RIGHT-OF-WAYS, RESERVATIONS, AGREEMENTS, AND/OR EASEMENTS OF RECORD. SUCH INFORMATION SHOULD BE OBTAINED AND CONFIRMED BY OTHERS THROUGH APPROPRIATE TITLE VERIFICATION. 4. UNDERGROUND UTILITIES, UTILITY SERVICES, FOUNDATIONS AND IMPROVEMENTS WERE NOT LOCATED AS A PART OF THIS SURVEY. 5. BEARINGS .SHOWN HERON .ARE BASED UPON THE PLAT OF RECORD, AND ARE RELATIVE TO THE LINE LABELED HERON AS (BEARING BASIS). DISTANCES ARE IN U.S. SURVEY FEET AND DECIMAL PARTS THEREOF. 6. ELEVATIONS SHOWN HEREON ARE BASED UPON THE NORTH AMERICAN VERTICAL DATUM OF 1988 (NAVD'88). 7. THIS SITE WAS SURVEYED UTILIZING TRIMBLE/SPRECTRA HARDWARE TOGETHER WITH SPECTRA SURVEY PRO REALTIME PROCESSING AND WAS BASED ON TRIMBLE'S "VRS NOW" NETWORK, AND/OR, THE FLORIDA PERMANENT REFERENCE NETWORK (FPRN). THE PROCEDURES AND NETWORK , DESIGN •,-MEETS THE, GEODETIC ACCURACY STANDARDS AND SPECIFICATIONS FOR USING GPS RELATED POSITIONINGi-AS'�tET •FORIN'BY.THE FEDERAL :GEODETIC CONTROL COMMITTEE IN THE MOST CURRENT PUBLICATION FOR •3RG Or4DER CLASS ONE R )RyHORIZONTAL CONTROL SURVEYS. ;� B. IN SOME INSTANCES, GRAPHIC REPRESENTATIONS AND SYMBOLS SH015j1V�4a�y 4f,AGGERAT�D TO MORE CLEARLY ILLUSTRATE THE RELATIONSHIP BETWEEN PHYSICAL`IMPROVEM`EF17S R.LOT LINES.'1IHE DIMENSIONS SHOWN SHALL CONTROL THE'LOCATION, OF THE IMPROVEMEN S;_ OVER THE SCALED POSITIONS. 9. THIS PROPERTY LIES IN FLOOD -ZONE "X." ACCORDING TO FEMA FLOOD INSURANCE RATE MAP%421:jj1C0o7OJ EFFECTIVE ON IIRUA, 2012. `0 , 10. REVISIONS SHOWN H ON 16DO N EPR NT A "FIEL ' RVF�j( UPDATE" UNLESS-QPi'ERWISroNOTED. FLORMAI' IC AEL T. OWEN PROFESSIONAL SURVEYOR AND MAPPER-111, �►c��ef�ty°> . SIGNATURE D E FLORIDA REGISTRATION #5556 4, 1_- Z_ ti U) io zo di' M a—'u)o F o g ►_ LL � o� U a ¢ NvLL Q d J I° wo LIJ ~ h N ¢ F- U_ �F �.. w UW ..I Uj U O a d Cd LL � o : N CD T• O W Q - U)rW . 2 oz 0 LU z W' I.z F- Z Lu a 0 z = o z Q �D QOQR U) .__I LL 0 —1 CL�_WILL �vw�� Q = ~ mN Z C) a- cn a —m 0 _ = U . Woa 00�5 co, J CO 0 _5 . 0 O U. DRAWN BY: FS CHECKED BY: MTO CREW: IP DATE: 6/10/2021 PROJECT. 21-309 1 OF 1