Loading...
HomeMy WebLinkAboutProject Informationb -a - wrightsoft° Load Short Form Entire House WebREPS, LLC Job: p#1301-605-0200-000-6 Date: June 2, 2021 By Josh Putman Plan: 8007 Hibiscus Road 1892 Commerce Avenue, Vero Beach, FL 32960 Phone: 80D-810-3280 Fax 888-971-2999 Email: sales@webrepshvac.com ftb: www.webrepswholesale.cem License: CAC054709 Project• • For: Joseph Gianna, Habitat for Humanity RECEIVED Ft. Pierce, FL OCT 0 8 2020 St. Htg Clg Infiltration Outside db (OF) 42 . 90 Method Simplified Inside db (OF) 70 75: Construction quality Semi -tight Design TD (OF) 28 15 Fireplaces 0 Daily range - L Inside humidity (%) 30 50 Moisture difference (grAb) 1 56 HEATING EQUIPMENT Make Goodman Trade Heat Strip Model AHRI ref Efficiency Heating input Heating output Temperature rise Actual airflow Airflowfactor Static pressure Space thermostat 100 EFF 8.0 kW 27297 Btuh 27 OF 920 cfm 0.054 cfrnBtuh 0.60 in H2O COOLING EQUIPMENT Make Goodman Mfg. Trade GOODMAN Cond GSX160301 F Coil ASPT30C14A AHRI ref 200825240 Efficiency 13:0 EER, 16 SEER Sensible cooling 20424 Btuh Latentcooling 7176 Btuh Total cooling . 27600 Btuh Actual airflow 920 cfrn Airflowfactor 0.051 cfmBtuh Static pressure 0.60 in H2O Load sensible heat ratio 0.75 ROOM NAME Area" (ft� Htg load (Btuh) Clg load (Btuh) HtgAVF (cfm) CIgAVF (cfrrl) Bed 2 197 3515 2405 188 122 clst 2 21 0 0 0 0 Bath 2 117 1103 1357 59 69 Bed 3 191 2897 2295 155 116 clst 3 18 0 0 0 0 Kit Din LR 497 5193 8497 278 430 pnty 21 0 0 0 0 Bed 175 2653 2797 142 141. clst 1 18 0 0 0 0 Rofh 1 07 4 on= CAn n 7 d0 Calculations approved byACCA to meet.all requirements of Manual J 8th Ed. ' WPlghtsoft® 2021-Jun-0216: Rght-Suite® Universal 202121.0.07 RSU16998 Page age I 1 J9CCA ...Habitat for Humanity PSUB007Hibiscus Road.rup Calc=W8 FrontDoorfaces: N CI Entire House 1335 17165 18194 920 920 Other equip loads . 0 1707 Equip. @ 1.00 RSM 19900 Latent cooling 6707 TOTALS 1 471 Rr, i )Mzn7 nnn nnn cvvVl VGv ALV Calculations approved byACCA to meet all requirements of Manual J 8th Ed. - wrightsoftm 2021-Jun-0216.43:47 ^' Right Suite®Universal 2021 21.0.07 RSU16998 Page 2 ACCN...Habitat forHumanity PSB8007Hibiscus Road.rup Calc=MJ8 FrontDoorfaces: N sue, Project Summary Job: p#1301.605-0200-000.6 wrightisol � , Date: June 2, 2021 Entire House By: Josh Putrnan WebREPS, LLC Plan: 8007 Hibiscus Road • 1892 Commerce fuenue, Vero Beach, FL 32960 Phone:800-810-3280 Fax 888-971-2999 Email: sales@webrepstmr-oom Wab: www.webrepswholesale.com License: CPC054709' Project• • For: Joseph Gianna, Habitat for Humanity Ft Pierce, FL Notes: 8007 Hibiscus Road Ft Pierce Florida p#1301-605-0200-000-6 Design Information Weather: St Lucie County Inti, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 56 grAb Heating Summary Structure 13885 Btuh Ducts 3280 Btuh Central vent (0 cfm) 0 Btuh (gone), Humidification 0 Btuh Piping 0 Btuh Equipment load 17165 Btuh Method Construction quality Fireplaces Area (ft ) Volume (f?) Air changes/hour Equiv AVF (cfm) Infiltration Simplified Semi -tight 0 He1335 C'3Ing 35 10678 10678 0.31 0.16 55 28 Heating Equipment Summary Make Goodman Trade Heat Strip Model AHRI ref Efficiency Heating input Heating output Temperature rise Actual airflow Air flowfactor Static pressure Space thermostat 100 EFF 8.0 kW 27297 Btuh 27 OF 920 clim 0.054 cfmBtuh 0.60 in H2O Sensible Cooling Equipment Load Sizing Structure 12772 Btuh Central 20 vent (0 cfm) Btuh (none) Blower 1707 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Equipment sensible load 19900 Btuh Latent Cooling Equipment Load Sizing Structure 5291 Btuh Ducts 1416 Btuh Central vent (0 cfm) 0 Btuh (none) Equipment latent load 6707 Btuh Equipment Total Load (Sen+Lat) 26607 Btuh Req. total capacity at 0.74 SHR 2.2 ton Cooling Equipment Summary Make Goodman Mfg. Trade GOODMAN Cond GSX160301 F Coil ASPT30C14A AHRI ref 200825240 Efficiency 13.0 EER,16 SEER Sensible cooling 20424 Btuh Latentcooling 7176 Btuh Total cooling 27600 Btuh Actual airflow 920 cfin Airflowfactor 0.051 cfmBtuh Static pressure 0.60 in H2O Load sensible heat ratio 0.75 Calculations approved byACCA to meet all requirements of Manual J 8th Ed � wrigt�tsoft' . �'� - •• • FZght Suite®Universa12021 21.0.07 RSU169982021-Jun-0216.43:47 Page 1 ACCA... Habitat for Humanity PSL\8007Hibiscus Roadrup Calc=MJB FrontDoorfaces:N Job #: p#1301-605-0200-000-6 Performed by Josh Putman for. Joseph Gianna R. Pierce, R- Sheet 1 WebREPS, LLC 1892 Commerce Avenue Vero Beach, FL32960 Phone:800-8103280 Fax: 888-971 2999 www.webrepswholesale.com sales@webrepshvac.com Scale:1 : 69 Pagel R4*&it@ Udvasal2g21 21.0.07RSU16998 20 WUJ M*44:03 -anlyPSLMUHbsasRmdttQ w- - wri htsoft Duct System Summary Job: p#1301.605-0200.000-0 g Date: June 2, 2021 Entire House W. Josh Putrnan WebREPS, LLC Plan: 8007 Hibiscus Road 1892 Commerce (venue, Vero Beach, FL 32960 Phone: 800-810-3280 Fax 888-971-2999 Email: sales@webrepshvac.com Mb: www.webrepswholesale.com License: CAC054709 evroject intormation For. Joseph Gianna, Habitat for Humanity Ft. Pierce, FL External static pressure Pressure losses Available static pressure Supply / return available pressure Lowestfriction rate Actual airflow Total effective length (TEL) Heating 0.60 in H2O 0.24 in H2O 0.36 in H2O 0.226 / 0.134 in H2O 0.084 in/100ft 920 cfm 427 ft Supply Branch Detail Table Cooling 0.60 in H2O 0.24 in H2O 0.36 in H2O 0.226 / 0.134 in H2O 0.084 in/100ft 920 chn Name Design (Btuh) Htg (cfm) Clg 0111) Design FIR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (fl) Trunk Bath 1 h 1805 97 43 0.093 6.0 Ox 0 VIFx 18.2 225.0 st2 Bath 2 c 1357 59 69 0.089 5.0 Ox 0 VIFx 24.6 230.0 st4 Bed 1 h 2653 142 141 0.093 7.0 Ox 0 VIFx 17.1 225.0 st2 Bed 2 h 3515 188 122 0.086 8.0 Ox 0 VI Fx 32.7 230.0 st4 Bed 3 h 2897 155 116 0.084 7.0 Ox 0 VI Fx 32.8 235.0 st4 Kit Din LR C 2124 70 107 0.100 6.0 Ox 0 VIFx 20.5 205.0 st3 Kit Din LR-A C 2124 70 107 0.099 6.0 Ox 0 VIFx 18.0 210.0 st3 Kit Din LR-B c 2124 70 107 0.096 6.0 Ox 0 VIFx 25.7 21.0.0 st3 Kit Din LR-C C 2124 70 107 0.101 6.0 Ox 0 VIFx 13.2 210.0 st3 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (drn) (cfm) FIR (fpm) (in) (in) Material Trunk st1 PeakAVF 920 920 0.084 613 15.0 12 x 18 RectFbg st2 PeakAVF 239 184 0.093 684 8.0 0 x 0 VinlFlx st1 st4 PeakAVF 403 306 0.084 513 12.0 0 x 0 VinlFlx st3 st3 PeakAVF 681 736 0.084 688 14.0 0 x 0 VinlFlx st1 - - wr ghtso_ft- ,� » ,. Right -Suite® Universal 2021 21.0.07 RSU16998 ACCA...HabitatforHumanity PSL\8007Hibiscus Road.rup CaIc=MJ8 Front Door faces: N 2021-Jun-0216:43:47 Page 1 I Return Branch Detail Table Name Grille Size (in) Htg (cfm) Clg (cfm) TEL 00 Design FIR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Mat! Trunk rb4 Ox 0 920 920 159.2 0.084 521 18.0 Ox 0 VIFx rtl Return Trunk Detail Table Name Trunk Type Htg Orn) Clg (cfm) Design FR Veloc (fpm) Diam (in) H x W (in) Duct Material Trunk rt1 PeakAVF 920 920 0.084 409 15.0 18 x 18 RectFbg wr ghtsoft- �, „,„,�, Right-Suite®Universal202121.0.07RSU16998 ACCA,..HabitatforHumanity PSU8007HibiscusRoad.rup Calc=MJ8 FrontDoorfaces: N 2021-Jun-0216:43:47 Page 2