Loading...
HomeMy WebLinkAboutTrussCJ1 CJ3 CJ5 r J8 J8 J8 00 J8 r CP CJ5 CJ3 CJ1 Typical Cornerset Specifications Attach End Jacks w/ (4) 16d ToeNails @ TC— & (3) 16d ToeNails @ BC Attach KingJack w/(3) 16d ToeNails @ TC & BC C ti - Typ. Corner Jack Placement-1' 10-15/16" 2'0" 2'0" 1' 1-1 /16" 411411 co LtdLO co r T_r --� —7 —� Ir- 00 00 O O O O O O O 000 U U U U oo 00 oo m m 00 m —� 1 201811 411411 00 00 00 00 00 00 ti LO M 'Y U U L) L)VC? 201811 1 A04 d' A03 A02 00 Attach Corner Jack w/(2) 16d ToeNails @ TC & BC 12 4 �— A01 B06 ,�gS1S4 t4l Pdpfl3,� k # Digitally signed by Ryan M Bays t ¢ t I d- DN:4 # < E Ryan Bays@WHEngineoring t, ►^t CN=Ryan M Bays, O=Whole House Rya I M BayS Engineering LLC, L=Fort Pierce, •� �}'I'J� 1 �".�L. � a 3 Florida G-US p l� Reason I am approving this document Date: 2021 09,28 08:27:36 04.00 + " o I� 44. C a C: C L C C z * NOTE: ALL TRUSS TO WALL AND/OR TRUSS TO LEDGER CONNECTIONS BY BUILDER. (UNLESS NOTED OTHERWISE) a * NOTE: ALL CEILING DROPS BELOW BEAM ARE BY BUILDER. (UNLESS NOTED OTHERWISE) * NOTE: THIS TRUSS PLACEMENT DIAGRAM IS TO SHOW ._ TRUSS I.D. AND TRUSS LOCATION ONLY. THE BUILDING DESIGNER IS ;RESPONSIBLE FOR THE STRUCTURAL STABILITY OF THE ENTIRE STRUCTURE. REFER TO THE INDIVIDUAL TRUSS ENGINEERING DRAWINGS FOR a GRAVITY AND UPLIFT LOADS. 02 FOR BRACING & ERECTION DETAILS REFER TO BCSI-03 a AND/OR ENGINEER OF RECORD. a t a REPRESENTS THE LEFT SIDE OF EACH TRUSS DRAWING a _ T ( NOTE: REFER TO SIMPSON CONNECTOR v C CATALOG FOR INSTALLATION DETAILS) g A LUS24 H HHUS46 Q - - - .O B LUS26 J THA422 R - - - o C HUS26 K MUS26 S - - - U D HUS28 L THJA26 T _ _ _ 00 11 E HHUS26-2 M - - - U - - - F HHUS28-2 N - - - V - - - y n `7 LUS46 P --- x --- O HBB HANGER BY BUILDER BBB BEAM BY BUILDER Z LSTA12 @ TC & BC * NOTE: LSTA STRAP c INDICATED TO BE USED IN °m Zt LSTA12 @ TC CONCORDANCE WITH CORNERSET DETAIL. Zb LSTA12 @ BC LOADING ROOF FLOOR WIND LOAD a� a LIVE LOAD 2 - ASCE 7-16 00 ❑ U DEAD LOAD C 0 [if LIVE LOAD - Residential - CAT 11 m �0 U DEAD LOAD 1 La - Enclosed m 0 0 TOTAL LOAD 10 - FBC 7TH ED. 2020 RES. m N DURATION FACTOR 1- _ TPI 2014 O REV DATE BY REMARKS V7 _ 02/09/2021 AA FBC 7TH ED. 2020 RES. CODE UPDATE O a� 12-1 O -- In _ C 0 m It is understood that above ❑ APPROVED conditions have been reviewed & o are acceptable for the fabrication ❑ APPROVED AS NOTED at trusses, elevations, pitches, a) overhangs, fascias,ceiling ❑ REVISE AND RESUBMITIn N elevations/pitches, bearing conditions & all detail pertaining ❑ REJECTED o to this truss placement plan. No back charges will be accepted without previous written approval DATE o from an A-1 Roof Trusses E representative. REVIEWED BY a PLAN DATE ARCH: --/--/---- STRUCT--/--/---- CUSTOMER HABITAT SL.(; 2 N O ID In JOB NAME THREE BEDROOM OPTION(S) Cn 6 so a COMMUNITY o / LOT# 8007 HIBISCUS ROAD C O CITY FORT PIEP(J' U c 0 COUNTY ST. LUCIE 0 BLDG. BLDG. o TYPE _ # _ t 7 O JOB # 86428 MASTER GHHS3B In ~ DRAWN SCALE 6j DATE o 09r2021 O MS NTS z Q a o „+I,IwM Z -TRUSSES Q A FLORIDA CORPORATION Ph 772-409-1010 / Fax 772-409-1015 � http://www.a 1 truss. com = I _ � I O O U IL) ca o ca= s =ems .O a) .0 0 r 2 :, c N Q) 'D ), a) F- N — 'Cf E tT .130 > 6 •«-• m o o = do a) L f0 U Q 0 COS 'D V N >' U O C 5E.o02Eoo C: -0 0 0 > a) is N in c a c c 0 M -00 o'er o oz o-0 o o .Ta 2 E E -0 ai 0 > N C C .•• c o o N 0 E'a�a E m E E 0 • ( F F c = c—a (n fn 2 iT C O N •cn Z, P ate.=�=�❑ N U L N E >+ T -0 b in ❑ E a U 0 c E m c or do 2 _~ c o, ca a) c m @ ° yam- E to c o L CD E c o rn.3 @ ❑ m ❑ E M ° N 0 — N o o a) o c a) J2-°:5 o~y ~` U m 3 o N ° cin a m8=E�'0.�� O U � II7 28 o�°:o is ❑.� ❑ o s ..a m 0 n m = o E E co a) U C >' U n C N O c rn v cn 3 a) -t� cn 3 .` .T o 0 y •_ > c aFy- ooEE a-0 E c o 00 �w m oar>'_ o E m Q ono=�� o a) 3 o c E a) W a) c n o Z ❑ ui N 2E N s r Q ca ac u0i O U E L C - 0 o 2 g M`� M � to �_0 0_ E _y cn � O N 'D to N 'on = U y = C m.E`�E°= fn U 0 o ° �' o c U (0 O a) 3 U 3 C L @ C C C a) (n (n 0 W W O tOon U t .0 Uv,OyE CL N •_ 00 '4)O G~ y U C O O Q > C y LJ ❑ C) :.Q E MO C Off.- — 0 U 2 fD t o m p O a) o WO t o Cn a) to 9 0 E Q> m 3 00 o v 0 0 rns iT a) ❑ a) L C a) a) m ❑ P 3 a) ~ ° a)a) 0 c -2E _ -0 — M tT 2062a0E Eo_g (n 'a -C ° 0 i �� = o C�5y n0-❑ c rn 0 =0a'tmc'O ,n "O a) C N 'C @ � 0ma)a)�o L, E c - .o 5 �- 0 - o .0 mLo. °) � o o�❑p o a o0 aa) o) 2 a) 0 o wo m 46 L_ > a) c t Cr C:v c°n N > O U L > m� m o a) C a) 0) N r_ Z? fn 'n 'L7 U O C C a) C C = Q) a) w O M 0 0 C to EoM O .` = C M O L p c o U -0 h 0 -a U a ,°- -o O m •U 02 O) ..... — a) - O) 2 a) C to fp •> i •C t N O L O U G 2 •L7) :D Q) _ f w o m c o a) o o c o 0 O C in .N C C L)C O O N t0 O to m U `y O O U CL T C f O @ v- V, ,0 a) C a`m aoi o �-, mIL-3 c m O O U C a) C C O fn C M, � -2) 0) n C rn to a o o a •� c coi ion ❑ O N tT tT V a) C C c m 3 0 as 0 =a°_ 0 ry - F- N N C 'D >' V a .0...- N 0 0 m� � o � '--c� c U 5 1 f- a c m m o a o 2 a) o c E -M o=@Y C> _ to E @ E n 4 ai 0-0 0 0 C O C a -o -o > a) = a >-0 m aia-oo 0 °)ca) w>a)EMmEa)c oo m Q) E U in � 2-8, EEoU c a) o a) N D 0 C a) C 0- 'D V O M •O a) t E_ -0 O i N` w U.4 rn C 0 .S C m 0 c 0 c�o 2 E° (p I 0) a) 0)o a) U '> (0 0 LC `� °o .E 0 `r' �. Lumber design values are in accordance with ANSI/TPI 1-2014 section 6.3 A-1 ROOF These truss designs rely on lumber values established by others. TRUSSES A FLORIDA CORPORATION RE: Job 86248 A-1 Roof Trusses 4451 St Lucie Blvd Fort Pierce FL 34946 Site Information: Customer Info: HABITAT ST. LUCIE COUNTY Project Name: LAKEWOOD PARK - SF Lot/Block: Model: THREE BEDROOM Address: 8007 HIBISUCUS RD Subdivision: City: County: St Lucie State: FL Name Address and License # of Structural Engineer of Record, If there is one, for the building. Name: License #: Address: City: General Truss Engineering Criteria Design Loads (Individual Truss Design Drawings Show Special Loading Conditions): Design Code: FBC 7th Ed. 2020 Res. / TPI 2014 Design Program: Alpine Engineered Products Wind Code: ASCE 7-16 Wind Speed: 160 Roof Load: 40.0 psf Floor Load: 0.0 psf This package includes 30 individual, dated Truss Design Drawings and 16 Additional Drawings. With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet conforms to 61 G15-31.003,section 5'of the Florida Board of Professional Engineers Rules. No. Seq # Truss Name Date No. Seq # Truss Name Date No. Seq # Truss Name Date 1 2645 A01 2/9/21 13 2651 1301 2/9/21 25 2601 CJ7 2/9/21 2 2581 A02 2/9/21 14 2592 B02 2/9/21 26 2606 HJ5 2/9/21 3 2582 A03 2/9/21 15 2593 B03 219/21 27 2607 HJ8 2/9121 4 2583 A04 2/9121 16 2594 B04 2/9121 28 12603 J7 2/9/21 5 2641 A05 2l9/21 17 2609 B05 2l9/21 29 2604 J8 2/9/21 6 2638 A06 219/21 18 2595 B06 2/9/21 30 2605 J8B 219121 7 2616 A07 2l9/21 19 2596 B07 2/9/21 31 STDL01 STD. DETAIL 219121 8 2613 A08 2/9/21 1 20 12597 B08 2/9121 32 STDL02 STD. DETAIL 2/9/21 9 2621 A09 2/9/21 21 2648 B09 219121 33 1 STDL03 STD. DETAIL 2/9/21 10 2635 A10 2/9/21 22 2598 CA 2/9/21 34 STDL04 STD. DETAIL 2/9121 11 2629 All 2/9/21 23 2599 CJ3 2/9/21 35 STDL05 STD. DETAIL 219121 12 2632I Al2 2/9/21 24 2600 CJ5 2/9/21 36, STDL06 STD. DETAIL 2/9121 The truss drawing(s) referenced have been prepared byAlpine Engineered Products, Inc. under my direcfsupervision based on the parameters provided byA=1: RoofTrusses, Ltd. russ Design Engineer's Name: Ryan Bays 4y license renewal date for the state of Florida is February 28,2023. IOTE: The seal on these drawings indicate acceptance of professional engineering responsibility solely forthe truss components shown. . 'he suifablity and use of components for any particu lar bu ild in g is the responsibility of the WIMP esigner, perANSVrPI-1 Sec. 2. 'he Truss Design Drawing(s)(TDD[s]) referenced have been prepared based on the construction ocuments (also referred to at times as'Structural Engineering Documents) provided by the BuilditIO Iesggner indicating the nature and character of the work 'he design criteria therein have been transfened to Ryan Bays PE by [A1 Roof Trusses orspecific nation]. These TDDs (also Waned to attunes as'Structural Delegated' :ngineering Documents) are specialty structural component designs and may be part of the pib]ecrt efene dorphased submittals. Asa Truss Design Engineer (ie, Specialty :ngineer�,he seal here and on the TDD represents an acceptance of professional engineering sponstoi* forthe design of the single Truss depicted on the TDD only. The Building Designer is sponsible forand shall coordinate and review the TDDs for ompafpilitywith the'vwritten engineering requirements. Please review all TDDs and all related notes. I�" Ryan Bays, RE. 4451 St Lucie, Blvd. Suite.201 Fort Pierce, FL 34946 Ryan by Ryan M Bays roving this 0827:20-04'09 Page 1 of 2 Lumber design values are in accordance with ANSI/TPI 1-2014 section 6.3 X" Q-1 ROOF These truss designs rely on lumber values established by others. TRUSSES A FLORIDA CORPORATION RE: Job CHHS36 No. Seq # Truss Name Date 37 STDL07 STD. DETAIL 2/9/21 38 STDL08 STD. DETAIL 2/9/21 39 STDL09 STD. DETAIL 2/9121 40 STDL10 STD. DETAIL 219121 41 STDL11 STD. DETAIL 2/9/21 42 STDL12 STD. DETAIL 2/9/21 43 STDL13 STD. DETAIL 2/9121 44 STDL14 STD. DETAIL 2/9/21 45 STDL15 STD. DETAIL 2/9/21 46 1 STDL16 STD. DETAIL 2/9121 Ryan Bays, P.E. Page 2 of 2 #91231 4451 St. Lucie Blvd, Suite 201 Fort Pierce, FL 34946 �Uo-oa3a 4451 ST. LUCIF BLVD FORT PIERCE, FL 34946 PH: 772-409-1010 FX: 772-409-1015 www.AlTruss.com TRUSS ENGINEERING BUILDER: HABITAT SLC PROJECT 8007 HIBISCUS RD COUNTY: EXEMPT LOT/BLK/MODEL: 8007 HIBISUCUS RD 4hJ`'A'j�ad JOB#: 86248 20 ' MASTER#: CHHS3B OPTIONS: NO OPTIONS It Job Truss Truss Type Qty Ply 02/09/2021 CHHS3B I A01 HIPS 1 I 1 I 2645 A �-- 2'6" � u+ %j,Pi TeREQ. Loading Criteria (psf) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 40.00 NCBCLL: 10.00 Load Duration: 1.25 Spacing: 24.0 " 16'4" 11'8" =5X6 =3X4 =3X4 =OXb =3X2f =4X11 =3Xb Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 5.0 psf MWFRS Parallel Dist: h/2 to h C&C Dist a: 4.43 ft Loc. from endwall: not in 13.01 GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord: 2x4 :SP 2400f-2.0E + SP M-31:; T2 2x4 SP M-30; T3,T4 2x4 SP #2; Bot chord: 2x6 SP 2400f-2.OE; 82 2x4 SP M-30; 133 2x4 SP 2400f-2.0E + SP M-31; Webs: 2x4 SP #3; W7 2x6 SP #2; Lt Slider: 2x6 SP #2; block length = 2.750' Rt Slider: 2x6 SP #2; block length = 2.750' Bracing (a) Continuous lateral restraint equally spaced on member. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 16.33 28.00 BC 75 0.00 44.33 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Loading Truss passed check for 20 psf additional bottom chord live load in areas with 42"-high x 24"-wide clearance. Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. A s 16'4" SEAT PLATE REQ. 35'4" 7'6" 44'4" Code / Misc Criteria Defi/CSI Criteria ♦ Maximum Reactions (Ibs) Code: FBC 7th Ed. 2020 Res. PP Deflection in loc L/defl L/# Gravity Non -Gravity TPI Std: 2014 VERT(LL): 0.145 L 368 360 Loc R+ / R- / Rh / Rw / U / RL Rep Factors Used: Yes VERT(CL): 0.312 L 171 240 B 1686 /- /- /1060 1783 /178 FT/RT:10(0)/10(10) HORZ(LL): -0.045 L - - N 2107 /- /- /1390 /899 /- Plate Type(s): HORZ(TL): 0.076 L - ' - Wind reactions based on MWFRS WAVE Creep Factor: 2.0 B Brg Width = 8.0 Min Req = 1.5 Max TC CSI: 0.681 N Brg Width = 6.0 Min Req = 1.7 Max BC CSI: 0.773 Bearings B & N are a rigid surface. Bearings B & N require a seat plate. Max Web CSI: 0.832 Maximum Top Chord Forces Per Ply (Ibs) t Wgt:241.5lbs Chords Tens.Comp. Chords Tens. Comp. VIEW Ver: 20.01.01A.0724.12 B - C 383 -937 G - H 1849 -2088 A - B 52 0 H -1 1488 -1539 C - D 1754 -2437 I - J 1461 -1689 D - E 1980 -2639 J - K 1437 -1704 E - F 1840 -2270 K -L 896 -1187 F - G 1861 -2249 L - M 863 -1059 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp B - S 2220 -1485 P - O 1079 - 725 S - R 2535 -1795 O - N 1079 - 725 R - Q 2534 -1796 N - L 1178 - 779 Q - P 1980 -1491 L - M 1083 - 811 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp B - C 2400 - 2442 Q - H 344 - 99 D - S 449 -453 H - P 825 - 691 S - E 449 - 222 P - 1 218 - 47 E - Q 424 - 544 P - K 2069 -1864 G - Q 372 - 88 K - N 1918 -1898 -WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Ryan Bays, P.E. responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field # 91231 use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon In writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. r-rinht Q MIA A-1 Reef Tn-- Renmducfine of this dnr+rment. in anv form. is nmhihhed without the written nermissine of A-1 Reef Tmccec_ Job Truss Truss Type Qty Ply 02/09/2021 CHHS3B A02 I HIPS 11 1 2581 T 1� PLATE K i f - 2,6" —}— Loading Criteria (psf) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 40.00 NCBCLL: 10.00 Load Duration: 1.25 Spacing: 24.0 " 18'4" 17'8" 118'4" =5X8 =5X6 G H III1.5X3 =3X4 =5X6 =3X4 =3X8 =3X6 Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 5.0 psf MWFRS Parallel Dist: h/2 to h C&C Dist a: 4.43 ft Loc. from endwall: not in 13.01 GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord: 2x4 SP #2; T1 2x4 SP 2400f-2.OE + SP M-31; T2 2x4 SP M-30; Bot chord: 2x6 SP 2400f-2.0E; B2 2x4 SP #2; B3 2x4 SP M-30; Webs: 2x4 SP #3; W8 2x6 SP #2; Lt Slider: 2x4 SP #3; block length = 1.750' Bracing (a) Continuous lateral restraint equally spaced on member. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 18.33 26.00 BC 72 0.00 44.33 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Loading Truss passed check for 20 psf additional bottom chord live load in areas with 42"-high x 24"-wide clearance. Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. 35'4" 44'4" M=tX6 SEAT PLATE REQ. i 7'6" �I =3X6(A1) Code / Misc Criteria Defl/CSI Criteria ♦ Maximum Reactions (Ibs) Code:FBC 7th Ed. 2020 Res. PP Deflection in loc Udefl L/# Gravity Non -Gravity TPI Std: 2014 VERT(LL): 0.147 F 999 360 Loc R+ / R- / Rh / Rw / U / RL Rep Factors Used: Yes VERT(CL): 0.306 F 999 240 T 1674 A /- /1049 /777 1196 FT/RT:10(0)/10(10) HORZ(LL): 0.034 M - - M 2121 A /- /1388 /887 /- Plate Type(s): HORZ(TL): 0.075 M - - Wind reactions based on MWFRS WAVE Creep Factor: 2.b T Brg Width = 8.0 Min Req = 1.5 Max TC CSI: 0.999 M Brg Width = 8.0 Min Req = 2.5 Max BC CSI: 0.985 Bearings T & M are a rigid surface. Bearings T & M require a seat plate. Max Web CSI: 0.738 Maximum Top Chord Forces Per Ply (Ibs) t Wgt:233.1 Ibs Chords Tens.Comp. Chords Tens. Comp. VIEW Ver. 20.01.01A.0724.12 B - C 477 -1256 G - H 1449 -1528 A- B 52 0 H- 1 1433 -1659 C - D 1537 - 2346 I - J 867 -1098 D - E 1805 - 2615 J - K 860 -1110 E - F 1817 - 2575 K - L 870 -1224 F - G 1672 - 2010 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. T - B 1209 - 360 P - O 1854 -1173 T - S 2173 -1330 O - N 988 - 606 S - R 2196 -1352 N - M 988 - 606 R - Q 2337 -1529 M - L 1216 - 759 Q - P 2336 -1529 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. B - C 1134 -1271 G - O 530 -498 S - D 603 -575 O - H 262 -75 D - R 450 -408 0-1 822 - 719 R- F 353 0 I- M 1921 -2078 F - P 513 -630 M - K 578 -452 G - P 530 - 226 tt "WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Ryan Bays, P.E. responsibility of the Owner, the Ov ner s authorized agent or the Building Designer, In the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field # 91231 IIIof the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by,all parties Involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Cn-dMt 0 2016 A•1 Reef T— — Ranrnd,w nn of thie der Ant. in am tone. Is nrnhihited withnut the written nenniacion of A-1 Roof Tmcce.¢ Job Truss Truss Type Qty Ply 02/09/2027 CHHS3B A03 I HIPS 1 1 1 2582 20'4" 1 3'8" .5X6 =6X6 G H 20'4" .T 4 12 � a-3X4F 1�-3X4 d. J —�3X6 i- �3X4D �4X6 E (a) �4X6 3�(C6) C 4X6(C6 - sqs• T S R Q P O N 1113 M III1.5X4 =3X4 =5X6 =3X4 =3X4 =3X6 =4X4 SEAj,PLATE REQ. SEAT PLATE REQ. 354° 7'6" f - 2'6" 1 44'4" -I Loading Criteria (psf) Wind Criteria Code / Misc Criteria Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-16 Code: FBC 7th Ed. 2020 Res. PP Deflection in loc L/defl L/# Gravity Non -Gravity TCDL: 10.00 Speed: 160 mph TPI Std: 2014 VERT(LL): 0.276 Q 999 360 Loc R+ / R- / Rh / Rw / U / RL BCLL: 0.00 Enclosure: Closed Rep Factors Used: Yes VERT(CL): 0.654 Q 636 240 U 1686 P /- /1044 /782 /214 BCDL: 10.00 Risk Category: 11 FT/RT:10(0)/10(10) HORZ(LL): 0.063 G - - M 2107 A /- /1365 /879 P EXP: C Kzt: NA Plate Type(s): HORZ(TL): 0.151 G - - Wind reactions based on MWFRS Des Ld: 40.00 Mean Height: 25.00 ft WAVE Creep Factor: 20. U Br Width = 8.0 Min Re 1.5 9 q = NCBCLL: 10.00 TCDL: 5.0 psf p Max TC CSI: 0.817 M Brg Width = 8.0 Min Req = 2.5 Load Duration: 1.25 BCDL: 5.0 psf Bearings U & M are a rigid surface. Spacing: 24.0 " MWFRS Parallel Dist: h/2 to h Max BC CSI: 0.995 Bearings U & M require a seat plate. C&C Dist a: 4.43 ft Max Web CSI: 0.784 Maximum Top Chord Forces Per Ply (Ibs) Loc. from endwall: not in 13.00 ft Wgt: 230.3 Ibs Chords Tens.Comp. Chords Tens. Comp. GCpi: 0.18 Wind Duration: 1.60 VIEW Ver: 20.01.01A.0724.12 B - C 521 -1332 G - H 1425 -1603 Lumber A- B 52 0 H- 1 1402 -1745 676 C - D 1759 -2705 I - J 557 -741 Top chord: 2x4 SP M-30; T1 2x4 SP 2400f-2.OE + D - E 1759 -2705 J - K 557 -741 SP M-31; T3 2x4 SP #2; E - F 1776 -2655 K - L 904 -1135 Bot chord: 2x6 SP 2400f-2.OE; B2 2x4 SP M-30; B3 2x4 SP #2; F - G 1446 -1777 Webs: 2x4 SP #3; W8 2x6 SP #2; Lt Slider: 2x4 SP #3; block length = 1.750' Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. Bracing (a) Continuous lateral restraint equally spaced on U - B 1282 -400 Q - P 1603 -893 member. U - T 2175 -1251 P - O 1271 - 754 T - S 2201 -1276 O - N 1271 - 754 Purlins S - R 2326 -1428 N - M 1055 -697 In lieu of structural panels or rigid ceiling use purlins R - Q 2326 -1428 M - L 1154 -778 to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) Maximum Web Forces Per Ply (Ibs) TC ' 24 20.33 24.00 Webs Tens.Comp. Webs Tens. Comp. BC 61 0.00 44.33 Apply purlins to any chords above or below fillers B - C 992 -1183 H - P 192 -52 at 24" OC unless shown otherwise above. T - D 579 -576 P -1 725 - 517 D - S 477 -369 1 - N 1234 -1224 Loading S - F 514 -42 N - K 1432 -981 Truss passed check for 20 psf additional bottom chord F - Q 822 - 959 K - M 1600 -1920 live load in areas with 42"-high x 24"-wide clearance. G - Q 421 -218 Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. "WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' forth. Verify design parameters and read notes on this Truss Design Drawing (rDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Ryan Bays, P.E. responsibility of the Owner, the Owners authorized agent or the Building Designer, In the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field # 91231 use of the Truss, Including handling, storage, Installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out In the TDD and the practices and 4451 St. Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer Is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Cnnvriaht Q 2016 A-1 Rnnf Tntcses — Renrndurtinn of this dnaiment. in anv form. is nmhibited without the wrfltnn nermissinn of A-1 Roof Tntcces. Job Truss Truss Type CHHS3B A04 I HIPS Qty Ply 1 1 1 02/09/2021 2583 11 f - 2'6" Loading Criteria (pst) TCLL: ' 20.00 TCDL: 10.00 BOLL: 0.00 BCDL: 10.00 Des Ld: 40.00 NCBCLL: 10.00 Load Duration: 1.25 Spacing: 24.0 " 22' III I.DAJ =JA4 =07,0 =JAC =JAO =4A4 PLATE REQ. Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: 11 EXP: C Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 5.0 psf MWFRS Parallel Dist: h/2 to h C&C Dist a: 4.43 ft Loc. from endwall: not in 13.0( GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord: 2x4 SP M-30; T1 2x4 SP 2400f-2.0E + SP M-31; T3 2x4 SP #2; Bot chord: 2x6 SP 2400f-2.0E; B2 2x4 SP M-30; B3 2x4 SP #2; Webs: 2x4 SP #3; W8 2x6 SP #2; Lt Slider: 2x4 SP #3; block length = 1.750' Bracing (a) Continuous lateral restraint equally spaced on member. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 58 0.00 44.33 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Loading Truss passed check for 20 psf additional bottom chord live load in areas with 42"-high x 24"-wide clearance. Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. 35'4" Code / Misc Criteria Code:FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Factors Used: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE 44'4" Defl/CSI Criteria PP Deflection in loc Udefl L/# VERT(LL): 0.150 Q 999 36 VERT(CL): 0.310 Q 999 24 HORZ(LL): 0.031 M - HORZ(TL): 0.067 M - Creep Factor: 2.0 Max TC CSI: 0.631 Max BC CSI: 0.994 Max Web CSI: 0.778 Wgt: 230.3 Ibs VIEW Ver. 20.01.01A.0724.12 22' .l A � 3X6(A1) SEAT PLATE REQ. 7,6" -� ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ /R- /Rh /Rw /U /RL S 1686 /- /- /1032 /782 /229 L 2107 /- /- /1350 /879 /- Wind reactions based on MWFRS S Brg Width = 8.0 Min Req = 1.5 L Brig Width = 8.0 Min Req = 2.5 Bearings S & L are a rigid surface. Bearings S & L require a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - C 576 -1470 F - G 1266 -1676 A-B 52 0 G-H 1241 -1671 C - D 1422 - 2435 H -1 658 - 931 D - E 1578 -2594 I - J 645 -995 E - F 1599 -2550 J - K 915 -1147 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. S - B 1414 -452 O - N 1400 -753 S - R 2272 -1241 N - M 1400 - 753 R - Q 2292 -1261 M - L 1064 - 708 Q - P 2215 -1249 L - K 1160 - 789 P - O 2214 -1250 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. B-C 917 -1139 G-O W6 -�07 R - D 529 -475 O - H 302 -259 D - Q 268 - 230 H - M 1034 -1031 Q - F 488 -16 M - J 1585 -1080 F - O 774 - 881 J - L 1633 -1960 A **WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin Ryan Bays, P.E. responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the # 91231 responsibility of the Owner, the Owner's authodzed agent or the Building Designer, In the context of the'IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field 4451 St. Lucie Blvd, Suite 201 use of the Truss, including handling, storage, Installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and dutiesof the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon inventing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Cnnvriaht C 2016 A-1 Ronf Tn-- Renrndudinn of this dmiment. in anv form. is nmhihited u IWI this written nermisclm of A-1 Rmf Tmsses. 31 Job CHHS3B Truss Truss Type Qty Ply A05 HIPS 1 1 02/09/2021 2641 a I. 20'6" _1_ 3'4" -1 20'6" .I ea5X6 ss6X6 F G SEAT PLATE REQ. SEAT PLATE REQ. 364" 7'6" -{ 44'4" =3X6(A1) Loading Criteria (psf) Wind Criteria Code / Misc Criteria Defi/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-16 Code: FBC 7th Ed. 2020 Res. PP Deflection in loc Udefl L/# Gravity Non -Gravity TCDL: 10.00 Speed: 160 mph TPI Std: 2014 VERT(LL): 0.303 P 999 360 Lac R+ / R- / Rh / Rw / U / RL BCLL: 0.00 Enclosure: Closed Rep Factors Used: Yes VERT(CL): 0.694 P 600 240 S 1520 /- /- /880 /684 /183 BCDL: 10.00 Risk Category: II FT/RT:10(0)/10(10) HORZ(LL): 0.053 F - - L 2112 /- /- /1361 /888 /- EXP: C Kzt: NA Des Ld: 40.00 Plate Type(s): HORZ(TL): 0.130 F - - Wind reactions based on MWFRS Mean Height: 25.00 ft WAVE, HS Creep Factor: 2.0 S Br Width = 8.0 9 Min Re 1.5 q = NCBCLL: 10.00 TCDL: 5.0 psf Max TC CSI: 0.873 L Brg Width = 8.0 Min Req = 2.5 Load Duration: 1.25 BCDL: 5.0 psf Bearings S & L are a rigid surface. Spacing: 24.0 " MWFRS Parallel Dist: h/2 to h Max BC CSI: 0.994 Bearings S & L require a seat plate. C&C Dist a: 4.43 ft Max Web CSI: 0.793 Loc. from endwall: not in 13.00 ft Maximum Top Chord Forces Per Ply (Ibs) Wgt: 219.1 Ibs Chords Tens.Comp. Chords Tens. Comp. GCpi: 0.18 Wind Duration: 1.60 VIEW Ver: 20.01.01A.0724.12 A - B 149 -655 F - G 1477 -1628 Lumber B - C 1989 -2698 G - H 1456 -1772 C - D 1881 -2611 H - I 5-731 Top chord: 2x4 SP M-30; T1 2x4 SP 2400f-2.OE + D - E 1892 - 2552 I - J 565 - 773 SP M-31; T3 2x4 SP 42; Bot chord: 2x4 :SP 2400f-2.0E + SP M-31:; E - F 1501 -1806 J - K 899 -1130 B2 2x4 SP M-30; B3 2x4 SP #2; Webs: 2x4 SP #3; Maximum Bot Chord Forces Per Ply (Ibs) Lt Slider: 2x6 SP #2; block length = 2.750' Chords Tens.Comp. Chords Tens. Comp. Bracing S - R 2461 -1681 O - N 1301 -795 (a) Continuous lateral restraint equally spaced on A - S 666 -136 N - M 1301 -795 member. R - Q 2315 -1520 M - L 1085 - 726 Q - P 2315 -1520 L - K 1145 - 773 Purlins P - O 1628 -941 In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Maximum Web Forces Per Ply (Ibs) Chord Spacing(in oc) Start(ft) End(ft) Webs Tens.Comp. Webs Tens. Comp. TC 24 20.50 23.83 BC 61 0.00 44.33 S - B 2000 -2270 G - O 183 -52 Apply purlins to any chords above or below fillers C - R 233 -54 O - H 720 -505 at 24" OC unless shown otherwise above. R - E 381 -34 H - M 1242 -1220 Loading E - P 811 -908 M - J 1485 -1031 F - P 462 - 271 J - L 1613 -1923 Truss passed check for 20 psf additional bottom chord live load in areas with 42"-high x 24"-wide clearance. Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. -WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin Ryan Bays, P.E. responsibility for the design of the single Truss depicted an the TDD only, under TPI-1. The design assumptions, loadingconditions, suitability and use of this Truss for any Building is the # 91231 responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field g451 St. Lucie Blvd, Suite 201 use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out In the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined In TPI-1. C nvrinht 0 2016 A-1 Rnnf Tmasas - Renmdurtinn of this dnniment. in anv fomn. is nrnliNted withnut thn written-Ission of A.1 Rnnf Tr-s. Job I russ Russ Type Qty Ply 02/09/2021 2638 CHHS3B A06 HIPS 1 1 fi i 18's" i7'4" 18'6" X. =5X8 F =5X6 G (=3X6(A1) =3X4 =4X6 =3X4 =3X8 =3X6 =oAb SEAT PLATE REQ. SEAT PLATE REQ. I-1 6 364" 7'6" -� 44'4" Loading Criteria (psf) Wind Criteria Code / Misc Criteria Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-16 Code: FBC 7th Ed. 2020 Res. PP Deflection in loc L/defl L/# Gravity Non -Gravity TCDL: 10.00 Speed: 160 mph TPI Std: 2014 VERT(LL): 0.190 E 999 360 Loc R+ / R- / Rh / Rw / U / RL BCLL: 0.00 Enclosure: Closed Rep Factors Used: Yes VERT(CL): 0.400 E 999 240 R 1508 /- P /885 /679 /165 BCDL: 10.00 Risk Category: II FT/RT:10(0)/10(10) HORZ(LL): -0.055 B - - L 2126 /- /- /1385 /895 /- EXP: C Kzt: NA Plate Type(s): HORZ(TL): 0.118 B - - Wind reactions based on MWFRS Des Ld: 40.00 Mean Height: 25.00 ft WAVE Creep Factor: 2.0 R Brg Width = 8.0 Min Req = 1.5 NC13CLL: 10.00 TCDL: 5.0 psf Max TC CSI: 0.814 L Brg Width = 8.0 Min Req = 2.5 Load Duration: 1.25 BCDL: 5.0 psf Bearings R & L are a rigid surface. Spacing: 24.0 " MWFRS Parallel Dist: h/2 to h Max BC CSI: 0.742 Bearings R & L require a seat plate. C&C Dist a: 4.43 ft Max Web CSI: 0.731 Maximum Top Chord Forces Per Ply (Ibs) Loc. from endwall: not in 13.00 ft Wgt: 221.2 Ibs Chords Tens.Comp. Chords Tens. Comp. GCpi: 0.18 Wind Duration: 1.60 VIEW Ver: 20.01.01A.0724.12 A - B 245 -707 F - G 1493 -1548 Lumber B - C 1958 -2659 G - H 1480 -1681 C - D 20-25H - I 866 -11 5 Top chord: 2x4 SP #2; T1 2x4 SP 2400f-2.OE + D - E 2017 -2545 I - J 843 -1112 SP M-31; T5 2x4 SP M-30; Bot chord: 2x4 SP M-30; 131 2x4 SP 2400f-2.OE + E - F , 1742 -2047 J - K 872 -1227 SP M-31; Webs: 2x4 SP #3; W6 2x6 SP #2; Maximum Bot Chord Forces Per Ply (Ibs) Lt Slider: 2x6 SP #2; block length = 2.750' Chords Tens.Comp. Chords Tens. Comp. Bracing R - Q 2428 -1654 O - N 1887 -1235 (a) Continuous lateral restraint equally spaced on A - R 711 -219 N - M 1021 -651 member. Q - P 2337 -1640 M - L 1021 - 651 P - O 2337 -1640 L - K 1218 - 758 Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 18.50 25.83 BC 75 0.00 44.33 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Loading Truss passed check for 20 psf additional bottom chord live load in areas with 42"-high x 24"-wide clearance. Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. R - B 1877 -2165 F - N 536 - 508 C - Q 207 - 29 N - G 244 - 83 Q - E 232 -40 N - H 798 - 699 E - O 553 - 566 H - L 1955 - 2097 F - O 570 - 263 L - J 580 - 454 , V0 "WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form. Verity design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building Is the -Ryan Bays, P.E. responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field fi 91231 use of the Truss, Including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out In the TDD and the practices and 4451 St Lurie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon In writing by all parties Involved. The Specialty Engineer Is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-I. C nvrinht 0 201A A-1 Rnnf Tmxvec — Renrodurlinn of this doarmant. in env fomi. N nmhlhiled without the written nermi-ton of A-1 Rnnf Tri—e". Job Truss Truss Type CHHS3B I A07 HIPS 1� I Ply 102/09/2021 2616 16'6" 11'4" - =5X6 III1.5X4 E F -,2 T 4 p o 3 I� A o 3X4 B 1 =3X6(C6 =3X6(C6) rl SEAT PLATE REQ. =5X6 G 16'6" 'Z�4X6 H 1-3X6 J--- 3X6(A1) Q P 0 N M L 1113- X III1.5X3 =3X4 =H0308 =3X8 =H0308 =4X4 SEAT PLATE REQ. 35'4" T6" 44'4" t Loading Criteria (psf) Wind Criteria TCLL: 20.00 Wind Std: "ASCE 7-16 TCDL: 10.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II EXP: C Kzt: NA Des Ld: 40.00 Mean Height: 25.00 ft NCBCLL: 10.00 TCDL: 5.0 psf Load. Duration: 1.25 BCDL: 5.0 psf Spacing: 24.0 " MWFRS Parallel Dist: h/2 to h C&C Dist a: 4.43 ft Loc. from endwall: not in 13.0( GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord: 2x4 SP M-30; T1 2x4 SP 2400f-2.OE + SP M-31; T3,T4 2x4 SP 42; Bot chord: 2x4 :SP 2400f-2.OE + SP M-31:; B2 2x4 SP M-30; B3 2x4 SP #2; Webs: 2x4 SP #3; W6 2x6 SP #2; Lt Slider: 2x6 SP #2; block length = 2.750' Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 16.50 27.83 BC 56 0.00 44.33 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Truss passed check for 20 psf additional bottom chord live load in areas with 42%high x 24"-wide clearance. Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Code / Misc Criteria Defl/CSI Criteria ♦ Maximum Reactions (Ibs) Code: FBC 7th Ed. 2020 Res. PP Deflection in loc Udefl U# ' Gravity Non -Gravity TPI Std: 2014 VERT(LL): 0.205 P 999 360 Loc R+ / R- / Rh / Rw / U / RL Rep Factors Used: Yes VERT(CL): 0.430 P' 969 240 R 1520 /-' /- /896 /685 /147 FT/RT:10(0)/10(10) HORZ(LL): -0.068 B - - K 2112 /- /- /1387 /900 /- Plate Type(s): HORZ(TL): 0.144 B - - Wind reactions based on MWFRS WAVE, HS Creep Factor: 2.0 R Brg Width = 8.0 Min Req = 1.5 Max TC CSI: 0.804 K Brg Width = 8.0 Min Req = 2.5 Max BC CSI: 0.997 Bearings R & K are a rigid surface. Bearings R & K require a seat plate. Max Web CSI: 0.970 Maximum Top Chord Forces Per Ply (Ibs) 1 Wgt:214.2lbs Chords Tens.Comp. Chords Tens. Comp. VIEW Ver: 20.01.01A.0724.12 A - B 496 -922 F - G 1936 -2044 B - C 2131 -2683 G - H 970 -1094 C - D 2055 -2545 H -1 945 -1112 D - E 2081 -2535 I - J 915 -1139 E - F 1936 -2044 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. R - Q 2470 -1832 N - M 1506 -1123 A - R 913 -464 M - L 1506 -1123 Q - P 2475 -1839 L - K 1040 - 707 P - O 2088 -1544 K - J 1135 - 789 O - N 2088 -1544 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. R - B 1831 -1961 F - N 497 - 281 Q - C 198 -144 N - G 820 - 724 C - P 303 -188 G - L 1137 - 976 P - E 480 -184 L -1 1594 -1302 E - N 237 -164 1- K 1844 -1960 -WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise slated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin Ryan Bays, P.E. responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building Is the I # 91231 responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPIA. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out In the TDD and the practices and 4451 St Lude Blvd, Suite 201 . guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in uniting by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Convdnht 0 2016 A-1 Rnnf Tnicnc- Rnnmdudinn of this d-3-nt. in anv form. Ic nmhlhitnd without thn wntlx nenni-inn of A-1 Rnnf Tntccna. .roo 1 cuss I cuss type City Ply CHHS3B A08 HIPS 1 1 1 1 14'6" i15'4" T 12 417 _3X4C =5X8 D III1.5X4 E -_ F B to A-3X4 P O N M L K III1.5X3 =3X4=3X6 =3X10 =3X6=4X6 PLATE�T A Loading Criteria (psf) Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-16 TCDL: 10.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II EXP: C Kzt: NA Des Ld: 40.00 Mean Height: 25.00 ft NC13CLL: 10.00 TCDL: 5.0 psf Load Duration: 1.25 BCDL: 5.0 psf Spacing: 24.0 " MWFRS Parallel Dist: h/2 to h C&C Dist a: 4.43 ft Loc. from endwall: not in 13.0( GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord: 2x4 SP #2; T1 2x4 SP 2400f-2.OE + SP M-31; Bot chord: 2x4 SP #2; 131 2x4 SP 2400f-2.OE + SP M-31; Webs: 2x4 SP #3; W6 2x6 SP #2; Lt Slider: 2x6 SP #2; block length = 2.750' Rt Slider: 2x6 SP #2; block length = 2.750' Bracing (a) Continuous lateral restraint equally spaced on member. Plating Notes All plates are 3X6(C6) except as noted. Purlins In lieu of structural panels or rigid ceiling use pudins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 14.50 29.83 BC 71 0.00 44.33 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. 02/09/2021 14'6" - \,4X6 2613 H Z-Z 3X4 I SEAT ( P l!SIREDPLATEWQ aIn %T ZE0. 35' 5'4„ -� � 'I Code / Misc Criteria Code:FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Factors Used: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE 44'4" Defl/CSI Criteria PP Deflection in loc Udefl L/# VERT(LL): 0.212 O 999 36 VERT(CL): 0.424 O 982 24 HORZ(LL): -0.058 B - - HORZ(TL): 0.117 B - - Creep Factor: 2.0 Max TC CSI: 0.963 Max BC CSI: 0.964 Max Web CSI: 0.758 Wgt: 224.7 Ibs VIEW Ver. 20.01.01A.0724.12 ♦ Maximum Reactions (Ibs), or •=PLF Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL Q 1526 /- /- /883 /708 /130 J 1842 /- /- /950 /771 /- X 24 /- P /14 /3 P R 337 /-119 /- /160 /168 /- Wind reactions based on MWFRS Q Brg Width = 8.0 Min Req = 1:5 J Brg Width = 8.0 Min Req = 2.2 J Brg Width = 64.0 Min Req = - R Brg Width = 8.0 Min Req = 1.5 Bearings Q, J, J, & R are a rigid surface. Bearings Q, J, J, & R require a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A - B 524 -838 E - F 2420 -2372 B - C 2335 -2690 F - G 1568 -1580 C - D 2325 -2493 G - H 604 -267 D - E 2420 -2372 H -1 657 -724 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp Q- P 2467 r 2052 M- L 1435 -1189 A - Q '835 - 504 L - K 1435 -1189 P - O 2468 -2059 K - J 230 -420 O - N 2320 -1939 J - R 619 -1069 N - M 2320 -1939 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. Q - B 1974 -2075 M - F 1140 -1059 P-C 213 -29 F-K 614 =586 C - O 211 -250 K - G 1899 -1395 D- O 365 - 8 G- J 1526 -1728 D - M 145 - 348 H - R 623 - 593 E - M 740 -482 K "WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional englneerin Ryan Bays, P.E. responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the # 91231 responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, Installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties Involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined In TPI-1. Cnnvrinht9) 2016 A-1 R-fTmcar_c- Ren Metien ofthie dnaiment. in anv form. is nrehihhed withnut the written nertniceinn of A-1 RonfTmcww. Job Truss Fruss -I ype city Ply UL/UWZUZ7 2621 CHHS3B A09 HIPS 1 1 .j �11'11-11/16" -}- 19'4" -}- 11'11-11/16"—� 12 =3X4 =3X6 1111.5X3 4 p E—_ F G H I "T rr �t D3X4 (a) Jz3X4=4X6((C6) m3X(C6)3X4 e3X6(CC 8 Lh m4XC6)B Lii3X4 M U T S R Q P O N 1111.5X3 =3X4 =H0308 =3X4 =3X8 =H0308 =3X4 1111.5X3 SEAIT/Ph6TE REQ. SEAT PLATE RiQ. 11i 1 6 41'4" 111J�16 6-1/16„ 43'3-3/8" 6-V 6" r Loading Criteria (pst) Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-16 TCDL: 10.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II EXP: C Kzt: NA Des Ld: 40.00 Mean Height: 25.00 ft NCBCLL: 10.00 TCDL: 5.0 psf Load Duration: 1.25 BCDL: 5.0 psf Spacing: 24.0 " MWFRS Parallel Dist: h/2 to h C&C Dist a: 4.43 ft Loc. from endwall: not in 6.50 GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord: 2x6 SP 2400f-2.0E; T2,T3 2x4 SP #2; Bot chord: 2x4 SP M-30; B2 2x4 SP #2; Webs: 2x4 SP #3; Lt Slider: 2x4 SP #2; block length = 1.750' Rt Slider: 2x4 SP #2; block length = 1.750' Bracing (a) Continuous lateral restraint equally spaced on member. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 11.97 31.31 BC 54 0.00 43.28 Apply puriins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind 'Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Code / Misc Criteria Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Factors Used: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE, HS Defl/CSI Criteria PP Deflection in loc Udefl L/# VERT(LL): 0.339 H 999 36, VERT(CL): 0.684 H 714 24, HORZ(LL): 0.092 N - - HORZ(TL): 0.187 N - Creep Factor: 2.0 Max TC CSI: 0.769 Max BC CSI: 0.989 Max Web CSI: 0.999 Wgt: 232.4 Ibs VIEW Ver.20.01.01A.0724.12 ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL B 1788 /- /- /1002 /822 /118 L 1788 /- /- /1002 /822 /- Wind reactions based on MWFRS B Brg Width = 8.0 Min Req = 2.1 L Brg Width = 8.0 Min Req = 2.1 Bearings B & L are a rigid surface. Bearings B & L require a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A - C 667 -971 G - H 3786 -3944 C - D 2959 - 3370 H -1 3788 - 3946 D - E 3135 - 3402 I - J 3133 - 3401 E - F 3766 - 3927 J - K 2960 - 3371 F - G 3786 - 3944 K - M 669 - 972 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp A - B 1003 - 675 R - Q 3950 - 3465 B - U 3068 -2608 Q - P 3194 -2738 U - T 3067 -2613 P - O 3194 -2738 T - S 3195 - 2742 O - N 3068 - 2612 S - R 3195 -2742 N - L 3069 -2608 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp B - C 2487 - 2647 H - Q 548 - 353 U - D 178 - 2 Q -1 896 - 964 D - T 207 - 389 1-0 236 -1 E- T 236 0 0-1 210 - 386 E - R 878 - 938 J - N 178 - 3 R - F 584 -360 K - L 2487 -2646 F-Q 77 -71 **WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin Ryan Bays, P.E. responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the I # 91231 responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field gg51 St Lucie Blvd, Suite 201 use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out In the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties Involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. C nvdnht 0 21116 A-1 Rnnf TnlcSP_C — R.—cl,,d ian of this drnrment. in anv in=. is nmhibited without the written nenniscinn of A-1 Rnnf Tnr. cec. duu r r uss I fuss I ype wry fly UZ/Uy/ZUZI CHHS313 A10 HIPS 1 1 2635 9 ) 7 =4) ih �— 9'11-11716" 12 =6X8 =3X4 4 l7 D E 23'4" i9'11-11/16" zi =H0308 III1.5X4 =6X8 F G H m3X6(C6)( 4X4 (a) (a) (a) =4X6 C ) 6A(C6) B I-3X6(C J �4 Kq Q P O N M L 1111.5X3 =H0308=4X4=4X8=H0308 III1.5X3 12 SELTPLATE REQ. 41'4" SEAT PLATER Q. Loading Criteria (psf) Wind Criteria Code / Misc Criteria Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-16 Code: FBC 7th Ed. 2020 Res. PP Deflection in loc Udefl U# Gravity Non -Gravity TCDL: 10.00 Speed: 160 mph TPI Sid: 2014 VERT(LL): 0.429 G 999 360 Loc R+ / R- / Rh / Rw / U / RL BCLL: 0.00 Enclosure: Closed Rep Factors Used: Yes VERT(CL): 0.863 G 566 244 B 1788 /_ /_ /1003 /934 /101 BCDL: 10.00 Risk Category: II FT/RT:10(0)/10(10) HORZ(LL): 0.099 1 - - J 1788 P P /1003 /934 P Des Ld: 40.00 EXP: C Kzt: NA Plate Type(s): HORZ(TL): 0.201 I - Wind reactions based on MWFRS Mean Height: 25.00 ft WAVE, HS Factor: 2.0 B Brg Width = 8.0 Min Req = 1.5 NCBCreep : 1 BCDL: 5.0 psf Max TC CSI: 0.779 J Brg Width = 8.l) Min Req = 1.5 Load Du on: Load Duration: 1.25 " BCDL: 5.0 psf Max BC CSI: 0.949 Bearings B & J are a rigid surface. • Spacing: 24.0 MWFRS Parallel Dist: 0 to h/2 Bearings B & J require a seat plate. C&C Dist a: 4.43 ft Max Web CSI: 0.769 Loc. from endwall: not in 6.50 Maximum Top Chord Forces Per Ply (Ibs) Wgt: 215.6 Ibs Chords Tens.Comp. Chords Tens. Comp. GCpi: 0.18 Wind Duration: 1.60 VIEW Ver: 20.01.01A.0724.12 A - C 967 -1287 F - G 4550 -4676 Lumber C - D 3308 -3574 G - H 4552 -4677 D - E 4518 -4648 H -1 3305 -3573 Top chord: 2x6 SP 2400f-2.0E; T2,T3 2x4 SP M-30; E - F 4550 -4676 I - K 962 -1282 Bot chord: 2x4 :SP 2400f-2.OE + SP M-31:; B2 2x4 SP M-30; Webs: 2x4 SP 43; Maximum Bot Chord Forces Per Ply (Ibs) Lt Slider: 2x4 SP #2; block length = 1.750' Chords Tens.Comp. Chords Tens. Comp. Rt Slider: 2x4 SP #2; block length = 1.750' A - B 1315 -995 O - N 4685 -4286 Bracing B - Q 3284 -2927 N - M 3286 -2916 (a) Continuous lateral restraint equally spaced on Q - P 3288 -2921 M - L 3286 -2916 member. P - O 3288 -2921 L - J 3282 -2922 Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing()n oc) Start(ft) End(ft) TC 24 9.97 33.31 BC 57 0.00 43.28 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp B - C 2690 -2529 N - H 1533 -1620 D- Q 290 0 G- N 691 -457 D- O 1504 -1581 L- H 294 0 O - E 719 -463 I - J 2693 -2533 E-N 82 =58 i -WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (Too) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineedn responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Ryan Bays, P.E. responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field # 91231 use of the Truss, Including handling, storage, Installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. (`.novdnhtQ 2016 A-1 RoofTnresnc- RenrMurlion of this dnannent. in anv fnnn. is nmhihited without the written nnm,l Ginn of A-1 RonfTnrcxac. - J. Job Truss Truss Type CHHS3B IA11 I HIPS try I1y IO2/09/2021 2629 .r �--- 7'11-11/16" -1 27'4" =4) 12 4 p =6X10 =-3X4 1111.5X4=4X6 D E F G =3X4 =-6X10 H I 7'11-11/16" (C6)4X4 6(LC B :C3X6X(C X6=) ' S R Q P O N M 1111.5X3 =4X6=H0308 =3X8 =H0308=4X6 III1.5X3 1 1111 6�TE REC. 41'4" SEAT PLATER Q.Ai 6- /�6" 1- 43'3-3/8" Loading Criteria (psf) Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-16 TCDL: 10.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II EXP: C Kzt: NA Des Ld: 40.00 Mean Height: 25.00 ft NCBCLL: 10.00 TCDL: 5.0 psf Load Duration: 1.25 BCDL: 5.0 psf Spacing: 24.0 " MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 4.43 ft Loc. from endwall: not in 6.50 GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord: 2x6 SP 2400f-2.0E; T2,T3 2x4 SP M-30; Bot chord: 2x4 :SP 2400f-2.OE + SP M-31:; B2 2x4 SP M-30; Webs: 2x4 SP #3; Lt Slider: 2x4 SP #2; block length = 1.750' Rt Slider: 2x4 SP #2; block length = 1.750' Bracing (a) Continuous lateral restraint equally spaced on member. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 7.97 35.31 BC 53 0.00 43.28 Apply puriins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Code / Misc Criteria Defl/CSI Criteria ♦ Maximum Reactions (Ibs) Code: FBC 7th Ed. 2020 Res. PP Deflection in loc L/defl L/# Gravity Non -Gravity TPI Std: 2014 VERT(LL): 0.606 F 806 360 Loc R+ / R- / Rh / Rw / U / RL Rep Factors Used: Yes VERT(CL): 1.222 F 400 244 B 1788 /- /- /1001 /935 /83 FT/RT:10(0)/10(10) HORZ(LL): 0.098 M - - K 1788 /- /- /1001 /935 /- Plate Type(s): HORZ(TL): 0.199 M - - Wind reactions based on MWFRS WAVE, HS Creep Factor: 2.0 B Brg Width = 8.0 Min Req = 1.5 Max TC CSI: 0.719 K Brg Width = 8.0 Min Req = 1.5 Max BC CSI: 0.956 Bearings B & K are a rigid surface. Max Web CSI: 0.817 Bearings B & K require a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Wgt:211.4lbs Chords Tens.Comp. Chords Tens. Comp. VIEW Ver. 20.01.01A.0724.12 A - C 1066 -1275 G - H 5775 -5905 C - D 3398 - 3575 H - I 5159 - 5255 D - E 5159 - 5255 I - J 3398 - 3575 E - F 5775 - 5905 J - L 1066 -1275 F - G 5775 - 5905 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A - B 1308 -1090 P - O 5322 - 5006 B - S 3283 - 3020 O - N 5322 - 5006 S - R 3286 -3013 N - M 3286 -3011 R - Q 5322 - 5008 M - K 3283 - 3019 Q - P 5322 - 5008 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. B - C 2640 -2543 P - H 643 - 652 D- S 213 0 H- N 894 - 679 D - R 2144 -2177 N - I 2144 -2177 R-E • 894 -679 M-1 213 0 E - P 643 -652 J - K 2640 -2543 F - P 561 - 377 -WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Ryan Bays, P.E. responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field # 91231 use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 SL Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Coovdnht A 2016 A-1 Rnnf Tn c _n - RenrMurJinn of thin drcurennt. in env form. k nmhlhNnd without the wdden nermiadnn of A-1 Roof Tnienec. aoo CHHS3B 1 russ I cuss I ype t:.tty I I-ly Al2 HIPS 1 2 U2/U9/2U21 2632 207# 122# 122# 122# 122# 122# 122# 122# 207# + 122/{ + 122#+ + 122#4 + 1221 + 122#+ + 122#4 + 122#4 122+ + 31'4" 12 4 =6X10 ===4X4 III 1.5X3=H0510 =3X4 =1­10308=4X4 m6X10 C D E F G H I J rs•1TTTTTT =3X6(C6) g3X4 s• =4XA6(C6) B T 1111.5X3 St�FAT PLATE RED. f =3X10 E1-10510 =3X10 41'4' 44'4" =4X4 =H0510 =3X10 6'6" =3X6(CV, KE3XX4 =4X6(C6) L M V III1.5X3 SEAT PLATE REQ. 'I 6!� �- 6'6-3/8"0318 i 2, 2, 2, 2, 2, 2, 1 /'>I 7 1/� 2, 2 2, 2, 2, 2, 2'0-3/8 ; 191# 82#82# 82# 82# 82# 82# 82# 82# 82# ` 82# 82# 82# 82# 82# 82## 1911## Loading Criteria (pst) Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-16 TCDL: 10.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II EXP: C Kzt: NA Des Ld: 40.00 Mean Height: 25.00 ft NCBCLL: 0.00 TCDL: 5.0 psf Load Duration: 1.25 BCDL: 5.0 psf Spacing: 24.0 " MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 4.43 ft Loc. from endwall: not in 6.50 GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord: 2x4 SP M-30; T2,T3 2x4 SP 2400f-2.0E + SP M-31; Bot chord: 2x6 SP 2400f-2.0E; Webs: 2x4 SP 43; W2 2x4 SP #2; Lt Slider: 2x4 SP #3; block length = 1.750' Rt Slider: 2x4 SP #3; block length = 1.750' Nailnote Nail Schedule:0.131"x3", min. nails Top Chord: 1 Row @12.00" o.c. Bot Chord: 1 Row @12.00" o.c. Webs : 1 Row @ 4" o.c. Use equal spacing between rows and stagger nails in each row to avoid splitting. (1) 1/2" bolts may be used for (2) 0.131"x3", min. nails on The Bottom Chord Only. Special Loads -(Lumber Dur.Fac.=1.25 / Plate Dur.Fac. 1.25) TC: From 61 pIf at 0.00 to 61 plf at 6.50 TC: From 31 pIf at 6.50 to 31 pIf at 37.83 TC: From 61 pIf at 37.83 to 61 pif at 44.33 BC: From 20 pIf at 0.00 to 20 pIf at 6.53 BC: From 10 pIf at 6.53 to 10 pIf at 37.80 BC: From 20 pIf at 37.80 to 20 pIf at 44.33 TC: 207 lb Conc. Load at 6.53,37.80 TC: 122 lb Conc. Load at 8.56,10.56,12.56,14.56 16.56,18.56,20.56,22.17,23.77,25.77,27.77,29.77 31.77,33.77,35.77 BC: 191 lb Conc. Load at 6.53,37.80 BC: 82 lb Conc. Load at 8.56,10.56,12.56,14.56 16.56,18.56,20.56,22.17,23.77,25.77,27.77,29.77 31.77,33.77,35.77 Code / Misc Criteria Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Factors Used: No Deft/CSI Criteria PP Deflection in loc Udefi U# VERT(LL): -0.967 E 505 360 VERT(CL): 1.586 E 308 244 ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL U 3092 /- /- /- /2083 /- FT/RT:10(0)/10(10) HORZ(LL): -0.119 C - - V 3092 /- /- /- /2083 /- Plate Type(s): HORZ(TL): 0.196 C - - Wind reactions based on MWFRS WAVE, HS Creep Factor: 2.0 U Brg Width = 8.0 Min Req = 1.5 Max TC CSI: 0.929 V Brg Width = 8.0 Min Req = 1.5 Max BC CSI: 0.989 Bearings U & V are a rigid surface. Max Web CSI: 0.707 Bearings U & V require a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Wgt:467.6lbs Chords Tens.Comp. Chords Tens. Comp. VIEW Ver. 20.01.01A.0724.12 A - B 1308 -1942 G - H 4832 -7083 Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 6.50 37.83 BC 76 0.00 44.33 Apply puriins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads and reactions based on MWFRS. Wind loading based on both gable and hip roof types. B - C 2105 - 3047 H - I 4832 - 7083 C - D 3943 - 5767 I - J 3933 - 5750 D - E 4832 - 7076 J - K 2110 - 3054 E - F 4832 - 7076 K - L 1319 -1956 F - G 4832 -7076 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp U - T 2847 -1966 P - O 5855 -4020 A - U 1881 -1260 O - N 5855 -4020 T - S 2834 -1949 N - M 2841 -1954 S - R 5870 -4029 M - K 2854 -1971 R - Q 5870 -4029 K - L 1895 -1271 Q - P 7121 -4873 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. C - T 265 -210 G - P 305 -276 C - S 3107 -2107 P -1 1308 -862 S - D 634 -760 I - N 642 -774 D - Q 1281 -850 N - J 3081 -2090 E - Q 302 -272 M - J 262 -204 Q - G 44 - 50 -WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (Too) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineedn Ryan Bays, P.E. responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the # 91231 responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out In the TDD and the practices and 4451 St. Lurie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss Fart Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon In writing by all parties Involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined In TPIA. Cnnvrinht 0 201a A-1 Roof Tmxsas - Rannxi-Jinn of Ihis d-inant. in anv form. is nmhihhad without tha vmttan nenniWnn M A-1 Rnnf Tnrccac. s Job CHHS3B Truss Iuss type B01 I SPEC 3 11y I UZ/UV/ZUZ9 2651 Loading Criteria (pst) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 40.00 NCBCLL: 10.00 Load Duration: 1.25 Spacing: 24.0 " ITY F 67-118'i 24-118' 15'2-118' A.FLAXE REQ. 1--7 1. 67-1/8' i Z4-1/8' Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 5.0 psf MWFRS Parallel Dist: h/2 to h C&C Dist a: 3.00 ft Loc. from endwall: not in 9.00 GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord: 2x8 SP 2400f-1.8E; T2 2x4 SP 2400f-2.0E + SP M-31; Bot chord: 2x4 :SP 2400f-2.OE + SP M-31 B2 2x6 SP 2400f-2.OE; Webs: 2x4 SP #3; W4 2x8 SP 2400f-1.8E; W7 2x6 SP #2; Lt Slider: 2x4 SP #3; block length = 1.750' Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 72 0.00 5.99 BC 67 9.53 15.10 Apply purins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. 'Right end vertical not exposed to wind pressure. Wind loading based on both gable and hip roof types. 152-1/8' RRO... 70'4-3/4' 4'�3/+i , 150# 15 Code / Misc Criteria Defl/CSI Criteria ♦ Maximum Reactions (Ibs) Code: FBC 7th Ed. 2020 Res. PP Deflection in loc L/defl U# Gravity Non -Gravity TPI Std: 2014 , VERT(LL): 0.276 F 614 360 Loc R+ / R- / Rh / Rw / U / RL B 787 /_ /_ /403 /272 /278 Rep Factors Used: Varies by Ld C 6A_RT(CL): 0.706 F 240 240 FT/RT:10(0)/10(10) HORZ(LL): 0.120 M - - K 852 /- /- /294 /297 /- Plate Type(s): HORZ(TL): 0.307 M - Wind reactions based on MWFRS WAVE, HS Creep Factor: 2.0 B Brg Width = 8.0 Min Req = 1.5 Max TC CSI: 0.669 K Brg Width = 8.0 Min Req = 1.5 Max BC CSI: 0.199 Bearings B & K are a rigid surface. Max Web CSI: 0.349 Bearing B requires a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Wgt: 117.6lbs Chords Tens.Comp. Chords Tens. Comp. VIEW Ver. 20.01.01A.0724.12 B - C 135 -509 E - F 159 -586 F - G 4814 - 5061 G - H 710 -1165 A-B 15 0 H-1 716 -1147 C - D 487 -1026 I - J 64 - 98 D - E 526 -1021 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - O 920 - 827 G - M 1389 -1063 O - N 825 - 700 M - L 1391 -1073 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp B-C 984-1104 M-1 319 -190 D - O 233 -136 1- L 1173 -1503 O - E 129 -158 L - K 666 - 851 E - N 1158 -1356 L - J 155 -72 N-F 1211 -1004 "WARNING- Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin responsibility for the design of the single Truss depicted on the TDD only, under TPI.1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Ryan Bays, P.E. responsibility of the Owner, the Owner's authorized agent or the Building Designer, In the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field 491231 use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties Involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined In TPI-1. Cnnvriaht 4 201E A-1 R-f Tmcses - Rnnrnd-Jinn of this do mtment. in anv form. is nmh1h8ed without the written nrnnicclnn of A-1 Rnnf Tnt. ��. JVY CHHS3B I I uaa I I rutiti I ype wry I illy B02 HIPM 1 1 UZ/UU/ZUZ7 2592 Loading Criteria (psf) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 40.00 NCBCLL: 10.00 Load Duration: 1.25 Spacing: 24.0 " 3.151s- r 14'6" SEAT PLATE REQ. 1'6" j 14'8' Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 5.0 psf MWFRS Parallel Dist: h/2 to h C&C Dist a: 3.00 ft Loc. from endwall: not in 9.00 GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Webs: 2x4 SP #3; Lt Slider: 2x6 SP #2; block length = 2.750' Bracing (a) Continuous lateral restraint equally spaced on member. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 14.50 16.17 BC 75 0.00 16.17 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Wind loading based on both gable and hip roof types. Code / Misc Criteria Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Factors Used: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE 16'2' DeflICSI Criteria PP Deflection in loc Udefl L/# VERT(LL): 0.058 C 999 361 VERT(CL): 0.118 C 999 241 HORZ(LL): -0.027 B - - HORZ(TL): 0.055 B - - Creep Factor: 2.0 Max TC CSI: 0.807 Max BC CSI: 0.667 Max Web CSI: 0.937 Wgt: 88.9 Ibs VIEW Ver. 20.01.01A.0724.12 1'8" --� a35X6 1111.5X3 D E SEAT PLATE REQ. ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL H 737 /- /- /454 /262 /253 1 578 /- /- /313 /272 P Wind reactions based on MWFRS H Brg Width = 8.0 Min Req = 1.5 1 Brg Width = 8.0 Min Req = 1.5 Bearings H & I are a rigid surface. Bearings H & I require a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A - B 85 -489 C - D 783 -962 B- C 622 - 955 D- E 0 0 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. H - G 868 - 882 G - F 155 - 211 A-H 519 -53 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. H - B 1059 -1025 D - F 652 - 480 C - G 566 - 361 E - F 117 - 50 G - D 848 - 776 3 I} "WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin n Bays P.E. RyanBays, responsibility for the design of the single Truss depicted an the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field91231 , use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties Involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terns are as defined in TPI-1. Cnnvrinht W 2016 A-1 Roof T­—Renroduclion ofthic d—ment. In anv form. in nmhihited withnut thn wdtNo nermindon of A-1 Roal"rn a Job CHHS3B If. k Truss B03 Iuss type HIPM ury rly uLfuLlrLucl 1 1 2593 3.1T6- 12'6" 3'8" =5X6 101.5X4 D E SEAT PLATE REQ. SEAT PLATE REQ. �-- 1'6" 14'S" 16'2" Loading Criteria (pst) Wind Criteria Code / Misc Criteria Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-16 Code: FBC 7th Ed. 2020 Res. PP Deflection in loc Udefi L/# Gravity Non -Gravity TCDL: 10.00 Speed: 160 mph TPI Std: 2014 VERT(LL): 0.054 C 999 360 Loc R+ / R- / Rh / Rw / U / RL BCLL: 0.00 Enclosure: Closed Rep Factors Used: Yes VERT(CL): 0.108 C 999 240 H 737 /- /- /454 /274 /218 BCDL: 10.00 Risk Category: II FT/RT:10(0)/10(10) HORZ(LL): -0.024 B - - I 578 /- /- /307 /288 /- EXP: C Kzt: NA Plate Type(s): HORZ(TL): 0.050 B - - Wind reactions based on MWFRS Des Ld: 40.00 Mean Height: 25.00 ft WAVE Creep Factor: 20. H Br Width = 8.0 Min Re 1.5 9 q = NCBCLL: 10.00 TCDL: 5.0 sf P Max TC CSI: 0.659 I Brg Width = 8.0 Min Req = 1.5 Load Duration: 1.25 BCDL: 5.0 sf P Max BC CSI: 0.826 Bearings H & I are a rigid surface. Spacing: 24.0 " MWFRS Parallel Dist: h/2 to h Bearings H & I require a seat plate. C&C Dist a: 3.00 ft Max Web CSI: 0.537 Maximum Top Chord Forces Per Ply (Ibs) Loc. from endwall: not in 9.00 Wgt: 81.9 Ibs Chords Tens.Comp. Chords Tens. Comp. GCpi: 0.18 Wind Duration: 1.60 VIEW Ver. 20.01.01A.0724.12 A - B 115 -412 C - D 883 -985 Lumber B- C 759 -988 D- E 0 0 Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Maximum Bot Chord Forces Per Ply (Ibs) Webs: 2x4 SP #3; Chords Tens.Comp. - Chords Tens. Comp. Lt Slider: 2x6 SP #2; block length = 2.750' H - G 898 -964 G - F 336 -490 Purlins A-H 443 -79 In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Maximum Web Forces Per Ply (Ibs) Chord Spacing(in oc) Start(ft) End(ft) Webs Tens.Comp. Webs Tens. Comp. TC 24 12.50 16.17 BC 75 0.00 16.17 H - B 1076 -1076 D - F 745 - 510 Apply pudins to any chords above or below fillers C - G 451 -252 E - F 257 -112 at 24" OC unless shown otherwise above. G - D 672 -541 Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Wind loading based on both gable and hip roof types. "WARNING- Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ('BUYER") ACKNOWLEDGMENT" form. Verify design parameters and read notes on this Truss Design Drawing (TOD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional englneerin responsibility for the design of the single Truss depicted on the TDD only, under TPIA. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Ryan Bays, P.E. responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field # 91231 use of the Truss, Including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out In the TDD and the practices and 4451 St Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon In writing by all parties Involved. The Specialty Engineer Is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined In TPI-1. Cnnvrinht 0 201e A-1 Roof To,-- Reproduction of this tlm,ment. in nnv form. L nmhihhnd without the written oernicsinn of A-1 Roof Tn,sses. r yNC sty t-ty uuuaf�u/, CHHS3B B04 HIPM 1 1 2594 &1s 16- Loading Criteria (psf) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 40.00 NCBCLL: 10.00 Load Duration: 1.25 Spacing: 24.0 " r 10'6" SEAT PLATE REQ. {' 1'6" 14W Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: not in 9.00 GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Webs: 2x4 SP #3; Lt Slider: 2x6 SP #2; block length = 2.750' Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 10.50 16.17 BC 75 0.00 16.17 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Wind loading based on both gable and hip roof types. Code / Misc Criteria Code: FBC 7th Ed. 2020 Res. TPI Sid: 2014 Rep Factors Used: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE 16'2" 5'8" =5X6 1113X4(R) D E Defl/CSI Criteria PP Deflection in loc Udefl L/# VERT(LL): -0.040 C 999 36i VERT(CL): 0.064 C 999 24 HORZ(LL): -0.008 F - - HORZ(TL): 0.014 B - - Creep Factor: 2.0 Max TC CSI: 0.759 Max BC CSI: 0.710 Max Web CSI: 0.729 Wgt: 86.1 Ibs VIEW Ver. 20.01.01A.0724.12 SEAT PLATE REQ. e ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL H 737 /- /- /452 /434 /258 1 578 P P /302 /414 P Wind reactions based on MWFRS H Brg Width = 8.0 Min Req = 1.5 1 Brg Width = 8.0 Min Req = 1.5 Bearings H & I are a rigid surface. Bearings H & I require a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A - B 85 -519 C - D 773 -695 B-C 951 -886 D-E 819 -617 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. H - G 804 -1074 G - F 10 -20 A - H 538 - 59 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. H - B 1352 - 983 G - E 721 - 949 C - G 294 -192 E - F 859 - 537 D - G 525 -177 4 r **WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes an this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin responsibility for the design of the single Truss depicted on the TDD.only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Ryan Bays, P.E. responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field # 91231 use of the Truss, Including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fart Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties. involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined In TPI-1. C —rinht Bl 2016 A-1 Rmf Tn— - Renmdtidinn of thLc dmanent. in am form. is nmhihltad without the written non WcJm of A-1 Rmf Tnrccxc. Job CHHS3B - 's Loading Criteria (psf) TOLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 40.00 NCBCLL: 10.00 Load Duration: 1.25 Spacing: 24.0 " Truss Truss Type Qty Ply 02/09/2021 B05 HIPM 1 1 354# 181# 181+ 181 17-114' 8'6' i 7'8- -� m2x4 SEAT PLATE REQ. SEAT PLATE REQ. �-- 1'6" 14W Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: not in 4.50 GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord: 2x4 :SP 2400f-2.OE + SP M-31:; T2 2x4 SP #2; Bot chord: 2x4 :SP 2400f-2.0E + SP M-31:; B2 2x4 SP M-30; Webs: 2x4 SP #3; Lt Slider. 2x6 SP #2; block length = 2.750' Special Loads -(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25) TC: From 61 plf at 0.00 to 61 pif at 8.50 TC: From 31 plf at 8.50 to 31 plf at 16.17 BC: From 20 plf at 0.00 to 20 plf at 8.65 BC: From 10 plf at 8.65 to 10 plf at 16.17 TC: 354 lb Conc. Load at 8.53 TC: 181 lb Conc. Load at 10.56,12.56,14.56 BC: 422 lb Conc. Load at 8.53 BC: 122 lb Conc. Load at 10.56,12.56,14.56 Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 8.50 16.17 BC 69 0.00 16.17 Apply puffins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads and reactions based on MWFRS. Right end vertical not exposed to wind pressure. Wind loading based on both gable and hip roof types. 16'2" 66-3l8" 2'0-3/8" � 2 -�� 2 422# 12 122# 12 Code / Misc Criteria Code:FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Factors Used: Varies by Ld FT/RT:10(0)/10(10) Plate Type(s): WAVE Deft/CSI Criteria PP Deflection in loc Udefl L/# VERT(LL): -0.117 C 999 36 VE'RT(CL): 0.200 H 107 24 HORZ(LL): 0.064 B - - HORZ(TL): 0.132 B - Creep Factor: 2.0 Max TC CSI: 0.704 Max BC CSI: 0.976 Max Web CSI: 0.755 Wgt: 83.3 Ibs VIEW Ver. 20.01.01A.0724.12 2609 ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL 1 1294 /- /- /- /925 /- J 1394 /- /- /- /1005 /- Wind reactions based on MWFRS I Brg Width = 8.0 Min Req = 1.5 J Brg Width = 8.0 Min Req = 1.6 Bearings I & J are a rigid surface. Bearings I & J require a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A - B 192 - 586 C - D 1161 -1597 B - C 1590 - 2143 D - E 1161 -1597 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. I - H 1958 -1440 H - G 1981 -1445 A-1 582 -182 G-F 10 -7 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. I - B 1525 -1768 D - G 626 - 574 C - H 450 - 99 G - E 1982 -1441 C - G 354 -480 E - F 1011 -1318 "WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form. Verify design parameters and read notes an this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin Ryan Bays, P.E. responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the I # 91231 responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field 4451 St. Lude Blvd, Suite 201 use of the Truss, including handling, storage. Installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out In the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon In writing by all parties Involved. The Specialty Engineer Is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined In TPI-1. CnmrinhtQ 2016 A-1 R-f-r-os-Rnnrmdurtinn of this dwimnnt. In am torn. Is nmhihited withnut Ma written nennissinn of A-1 Roof Tniccec. Joo truss I russ I ype ury rly o2/09/2021 CHHS3B B06 HIPM 1 1 2595 3-1Tc { — 2W r 14'4" SEAT PLATE REQ. f' 1,6n 7'10" 6X6 1113X6(R) F G SEAT PLATE REQ. 20W 22'2" Loading Criteria (psq Wind Criteria Code / Misc Criteria Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-16 Code: FBC 7th Ed. 2020 Res. PP Deflection in loc L/defl L/# Gravity Non -Gravity TCDL: 10.00 Speed: 160 mph TPI Std: 2014 VERT(LL): -0.102 1 209 360 Loc R+ / R- / Rh / Rw / U / RL BCLL: 0.00 Enclosure: Closed Rep Factors Used: Yes VERT(CL): 0.170 D 999 240 J 1153 /- /- /745 /563 /298 BCDL: 10.00 Risk Category: II FT/RT:10(0)/10(10) HORZ(LL): 0.048 C - - K 815 /- /- /423 /444 /- EXP: C Kzt: NA Des 40.00 Plate Type(s): HORZ(TL): 0.067 C - - Wind reactions based on MWFRS Mean Height: 25.00 ft WAVE Creep Factor: 2.0 J Brg Width = 8.0 Min Req = 1.5 NCBCLL: 10.00 TCDL: 5.0 psf Max TIC CSI: 0.720 K Br Width = 8.0 Min Re 1.5 g q = Load Duration: 1.25 BCDL: 5.0 psf " Max BC CSI: 0.552 Bearings J & K are a rigid surface. Spacing: 24.0 MWFRS Parallel Dist: h/2 to h Bearings J & K require a seat plate. C&C Dist a: ft Max Web CSI: 0.769 Loc. from not in 9.00 dwa Maximum Top Chord Forces Per Ply (Ibs) GCpi: i: 0.1l:8 .1 Wgt: 128.8 Ibs Chords Tens.Comp. Chords Tens. Comp. Wind Duration: 1.60 VIEW Ver: 20.01.01A.0724.12 B - C 85 -657 D - E 871 -1005 Lumber A - B 52 0 E - F 889 - 980 Top chord: 2x4 SP M-30; T1 2x4 SP 2400f-2.OE + C - D 1205 -1445 F - G 948 - 895 SP M-31; Bot chord: 2x6 SP 2400f-2.0E; B2 2x6 SP #2; Maximum Bot Chord Forces Per Ply (Ibs) Webs: 2x4 SP #3; Chords Tens.Comp. Chords Tens. Comp. Lt Slider. 2x4 SP #3; block length = 1.750' J - B 761 -99 I - H 0 0 Bracing J -1 1324 -1371 (a) Continuous lateral restraint equally spaced on member. Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. Purlins In lieu of structural panels or rigid ceiling use purins B - C 1557 -1171 1- G 1051 -1112 to laterally brace chords as follows: D - I 428 -446 G - H 981 - 747 Chord Spacing(in oc) Start(ft) End(ft) F - I 649 -249 TC 24 14.33 22.17 BC 120 0.00 22.17 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Wind loading based on both gable and hip roof types. "WARNING- Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering Q.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin P.E. , Bays Ryan responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Bays, responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, Installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lurie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties Involved. The Specialty Engineer Is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms areas defined in TPI-1. C—riahttd 2n16 A-1 RnofTnicsm— Renroduntinn of this dnmmeni. In anvfnrn. is nrohihllad without thn written narmi. Ginn of A-1 Rnnf Tmcces. Job CHHS3B Truss B07 Truss Type HIPM 1city 1y I oz/os/zozl 1 2596 3-1T• SEAT PLATE REQ. 1'6" '— 12'6" 9,8„ =5X6 =3X4 III1.5X4 D E F L SEAT PLATE REQ. 20'8" 22'2" T 1 Loading Criteria (psf) Wind Criteria Code / Misc Criteria Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-16 Code: FBC 7th Ed. 2020 Res. PP Deflection in loc Udefl U# Gravity Non -Gravity TCDL: 10.00 Speed: 160 mph TPI Std: 2014 VERT(LL): 0.084 C 999 360 Loc R+ / R- / Rh / Rw / U / RL BCLL: 0.00 Enclosure: Closed Rep Factors Used: Yes VERT(CL): 0.168 C 999 240 K 978 /- /- /581 /374 1218 BCDL: 10.00 Risk Category: II FT/RT:10(0)/10(10) HORZ(LL): -0.030 B - - L 823 /- /- 1430 /479 /- EXP: C Kzt: NA Plate Type(s): HORZ(TL): 0.060 B - - Wind reactions based on MWFRS Des Ld: 40.00 Mean Height: 25.00 ft WAVE Creep Factor: 20. K Br Width = 8.0 Min Re 1.5 9 q = NCBCLL: 10.00 TCDL: 5.0 sf . p Max TC CSI: 0.810 L Brg Width = 8.0 Min Req = 1.5 Load Duration: 1.25 BCDL: 5.0 psf Max BC CSI: 0.966 Bearings K & L are a rigid surface. Spacing: 24.0 " MWFRS Parallel Dist: h/2 to h Bearings K & L require a seat plate. C&C Dist a: 3.00 ft Max Web CSI: 0.734 Maximum Top Chord Forces Per Ply (Ibs) Loc. from endwall: not in 9.00 Wgt: 114.1 Ibs Chords Tens.Comp. . Chords Tens. Comp. GCpi: 0.18 Wind Duration:1.60 VIEWVer.20.01.01A.0724.12 A -B 180 -282 D-E 1185 -1064 Lumber B- C 1290 -1430 E- F 0 0 C-D 1162 -1168 Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; 132 2x4 SP M-30; Webs: 2x4 SP #3; Maximum Bot Chord Forces Per Ply (Ibs) Lt Slider: 2x6 SP #2; block length = 2.750' Chords Tens.Comp. Chords Tens. Comp. Purlins K - J 1303 -1412 I - H 1303 -1417 A - K 279 -159 H - G 720 - 976 In lieu of structural panels or rigid ceiling use purlins J - I 1303 -1417 to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 12.50 22.17 Maximum Web Forces Per Ply (Ibs) BC 87 0.00 22.17 Webs Tens.Comp. Webs Tens. Comp. Apply purling to any chords above or below fillers at 24" OC unless shown otherwise above. K - B 1408 -1342 H - E 473 -279 J-C 131 -4 E-G 1294 -954 Wind C - H 242 -257 F - G 236 -120 Wind loads based on MWFRS with additional C&C D - H 213 -5 member design. Right end vertical not exposed to wind pressure. Wind loading based on both gable and hip roof types. -WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin Ryan Bays, P.E. responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the 11191231 responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, Installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 SL Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties Involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined In TPI.1. Cnnvrioht 0 201(1 A-1 Rmf Tmcssn — Renrnrhrctinn of this dnaimnnt. In am torn. is nrohihited without the written nermissinn of A•1 Roof Tn— Job Truss Truss Type Qty Ply 02/09/2021 CHHS3B B08 HIPM 11 I1 I 2597 a-1T• 10'6" SEAT PLATE REQ. �- 1'6" A 20'8" 22'2" 11'8" III 1.5X4 IL SEAT PLATE REQ. fl Loading Criteria (psq Wind Criteria Code / Misc Criteria Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-16 Code: FBC 7th Ed. 2020 Res. PP Deflection in loc Udefl U# Gravity Non -Gravity TCDL: 10.00 Speed: 160 mph TPI Std: 2014 VERT(LL): -0.079 C 999 360 Loc R+ / R- / Rh / Rw / U / RL BCLL: 0.00 Enclosure: Closed Rep Factors Used: Yes VERT(CL): 0.138 J 999 240 K 978 P P /578 /603 • /258 BCDL: 10.00 Risk Category: II FT/RT:10(0)/10(10) HORZ(LL): -0.018 G - - L 823 /- /- /426 /569 %- Des Ld: 40.00 EXP: C Kzt: NA Plate Type(s): HORZ(TL): 0.030 G - - Wind reactions based on MWFRS Mean Height: 25.00 ft WAVE Creep Factor: 2.0 K Brg Width = 8.0 Min Req = 1.5 NCBCLL: 10.00 TCDL: 5.0 sf p Max TC CSI: 0849 L Brg Width = 8.0 Min Req = 1.5 Load Duration: 1.25 " BCDL: 5.0 psf• . Max BC CSI: 0.955 Bearings K & L are a rigid surface. Spacing: 24.0 MWFRS Parallel Dist: 0 to h/2 Bearings K & L require a seat plate. C&C Dist a: 3.00 ft Max Web CSI: 0.705 Maximum Top Chord Forces Per Ply (Ibs) Loc. from endwall: not in 9.00 f Wgt: 118.3 Ibs Chords Tens.Comp. Chords Tens. Comp. GCpi: 0.18 Wind Duration: 1.60 VIEW Ver. 20.01.01A.0724.12 A - B 66 -340 D - E 1357 -1040 Lumber B - C 1477 -1395 E - F 1357 -1040 C - D 1442 -1313 Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Webs: 2x4 SP #3; Maximum Bot Chord Forces Per Ply (Ibs) Lt Slider: 2x6 SP #2; block length = 2.750' Chords Tens.Comp. Chords Tens. Comp. Bracing K - J 1262 -1520 I - H 1214 -1457 (a) Continuous lateral restraint equally spaced on A - K 343 -64 H - G 11 -15 member. J -1 1214 -1457 Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 10.50 22.17 BC 67 0.00 22.17 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Wind loading based on both gable and hip roof types. Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. K - B 1733 -1405 E - H 821 - 395 C - J 209 -206 H - F 1203 -1569 D- J 265 0 F- G 1106 -772 D - H 148 -204 -WARNING- Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise staled on the TDD, only Alpine . connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin Ryan Bays, P.E. responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the # 91231 responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, Including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out In the TDD and the practices and 4451 St. Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless othenvise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Cnnvriaht 4 2016 A-1 Rmf Tnicces - Rnorad-linn of this dnmmant, in anv form. is nmhihhed vAhnut the written nennission of A-1 Rmf Tnrssn-s. Job CHH Loading Criteria (psf) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 40.00 NCBCLL: 10.00 Load Duration: 1.25 Spacing: 24.0 " >1y6:- Truss B09 I^ 8W Truss Type HIPM 174181#+ 181 1811 e5X8 1ty I Ply 02 O912021 2648 1814 181#+ 1814 181if_3f�, _13,8. ®4X4 T N rn 1 SEAT PLATE REQ. SEAT PLATE REQ. 1'6° j 20'8' Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: not in 4.50 GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord: 2x4 :SP 2400f-2.OE + SP M-31:; Bot chord: 2x6 SP 2400f-2.OE; Webs: 2x4 SP #3; W3 2x4 SP #2; Lt Slider: 2x4 SP #3; block length = 1.750' Bracing (a) Continuous lateral restraint equally spaced on member. Special Loads (Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25) TC: From 61 plf at 0.00 to 61 plf at 8.50 TC: From 31 plf at 8.50 to 31 plf at 22.17 BC: From 20 plf at 0.00 to 20 plf at 8.50 BC: From 10 plf at 8.50 to 10 pif at 22.17 TC: 174 lb Conc. Load at 8.50 TC: 181 lb Conc. Load at 9.15,11.15,13.15,15.15 17.15,19.15,21.15 BC: 300 lb Conc. Load at 8.50 BC: 122lb Conc. Load at 9.15,11.15,13.15,15.15 17.15,19.15,21.15 Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 8.50 22.17 BC 68 0.00 22.17 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads and reactions based on MWFRS. Right end vertical not exposed to wind pressure. Wind loading based on both gable and hip roof types. 22'2° 71,3f22 2 2 122# 2 2 12 2 2 122# 300# 122# 122# 122# Code / Misc Criteria Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Factors Used: Varies by Ld FT/RT:10(0)/10(10) Plate Type(s): WAVE, HS Deft/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): -0.226 C 999 361 %q-RT(CL): 0.345 1 709 240 HORZ(LL): 0.060 B - - HORZ(TL): 0.103 B - - Creep Factor: 2.0 Max TC CSI: 0.887 Max BC CSI: 0.990 Max Web CSI: 0.875 Wgt: 119.0 Ibs VIEW Ver. 20.01.01A.0724.12 ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ /R- /Rh /Rw /U /RL J 1838 /- P P /1316 P K 1998 P P P /1420 P Wind reactions based on MWFRS J Brg Width = 8.0 Min Req = 1.5 K Brg Width = 8.0 Min Req = 1.7 Bearings J & K are a rigid surface. Bearings J & K require a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A - B 1318 - 2091 C - D 2593 - 3623 B - C 2577 - 3528 D - E 2593 - 3623 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. J -1 3286 -2389 H - G 3301 -2385 A - J 2023 -1260 G - F 33 - 30 I- H 3301 -2385 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. C -1 292 0 G - E 3877 - 2768 C - G 409 - 224 E - F 1417 -1794 D - G 1104 - 980 -WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineefin Ryan Bays, P.E. responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the # 91231 responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field 4451 SL Lucie Blvd, Suite 201 use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out In the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties Involved. The Specialty Engineer Is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI.1. C nwinht 02R1e A-1 Rnnf Tnr. �r_v-R...du Linn of thL¢ domtmnnt. In anv fnnn. is nmhihand urithout the written namiccinn of A-1 RnnfTnimm. J00 CHHS3B 1 russ I russ I ype Qty Ply CA I JACK 1 8 1 1 02/09/2021 2598 Loading Criteria (psf) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 40.00 NCBCLL: 10.00 Load Duration: 1.25 Spacing: 24.0 " Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; 12 4 B 2X4(A1) A T -T_ 7-15/16" 3-15/�16" C Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: 11 EXP: C Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 8 0.36 1.00 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Additional Notes ****` BEARING ANALOG MODIFIEDI Ie--1' -__I Code / Misc Criteria Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Factors Used: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc Udefl L/# VERT(LL):0.000 - - 360 VERT(CL): 0.000 - - 240 HORZ(LL):0.000 - - - HORZ(TL): 0.000 - - - Creep Factor: 2.0 Max TC CSI: 0.021 Max BC CSI: 0.007 Max Web CSI: 0.000 Wgt: 4.2 Ibs VIEW Ver: 20.01.01A.0724.12 ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ /R- if Rh /Rw /U /RL B 35' /- /46 /25 /32 /26 C 21 /- /46 /11 /6 /39 Wind reactions based on MWFRS B Brig Width = 1.5 C Brg Width = 1.5 Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. A-B 55 -131 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. A - C 156 -49 t **WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. Asa Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin responsibility for the design of the single Truss depicted an the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Ryan Bays, P.E. responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field ft 91231 use of the Truss, Including handling, storage, Installation and bracing shall be the responsibility of,the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. C—TIaht 0 2016 A-1 Rnnf Tnu-- Renrutudion of thi." dman nt. in anv in=. La nmhibRad without thn written narmlydan of A-1 Rnnf Tni-ii, Job CHHS3B c Truss Truss Type CJ3 JACK Qty Ply 8 1 u21U912U2i 2599 Loading Criteria (psf) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 40.00 NCBCLL: 10.00 Load Duration: 1.25 Spacing: 24.0 " Lumber Top chord: 2x4 SP #2; Bat chord: 2x4 SP 42; Webs: 2x6 SP #2; 12 4 C III 1.5X B X4(A1 HB 11-1/4" 3-15 16" F 4E D 1113X6(`*) SEAT PLATE REQ. �- 1'6" -- Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Plating Notes (") 1 plate(s) require special positioning. Refer to scaled plate plot details for special positioning requirements. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 36 0.00 3.00 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. 11-1 /4" l I- 3' (I Code I Misc Criteria DeflICSI Criteria ♦ Maximum Reactions (Ibs) Code: FBC 7th Ed. 2020 Res. PP Deflection in loc Udefl L/# Gravity Non -Gravity TPI Std: 2014 VERT(LL): 0.019 E 999 360 Loc R+ / R- / Rh / Rw / U / RL F 389 /- /- /321 /208 /73 Rep Factors Used: Yes VERT(CL): 0.037 E 661 240 FT/RT:10(0)/10(10) HORZ(LL): -0.006 C - - D - /-79 P /59 /85 /- Plate Type(s): HORZ(TL): 0.013 C - - C - /-85 P /41 f75 P WAVE Creep Factor: 2.0 Wind reactions based on MWFRS Max TC CSI: 0.279 F Brg Width = 8.0 Min Req = 1.5 Max BC CSI: 0.191 D Brg Width = 1.5 Min Req = - Max Web CSI: 0.104 C Brg Width = 1.5 Min Req = - Bearing F is a rigid surface. Wgt: 11.9 Ibs Bearing F requires a seat plate. Maximum Top Chord Forces Per Ply (Ibs) VIEW Ver. 20.01.01A.0724.12 Chords Tens.Comp. Chords Tens. Comp. A - B 75 - 249 B - C 28 -40 Maximum Bat Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A-E 288 -43 E-D 0 0 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. B - E 674 - 237 "WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verity design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise staled on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineedn responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Ryan Bays, P.E. responsibility of the Owner, the Owner's authorized agent or the Building Designer, In the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field # 91231 use of the Truss, Including handling, storage, Installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 SL Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in wilting by all parties Involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined In TPI-1. f'—daht 0 2n1fi A-1 Rnof Tmsses — Renmr1iidinn of this donimant. In anv fnnn. is nmhihitnd withoet tha wriftnn nwml Ginn of A-1 Rnnf Tnj c. Job CHHS3B Truss CJ5 Truss Type Qty Ply 02/09/2021 JACK 18 I 1 2600 Loading Criteria (psf) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 40.00 NCBCLL: 10.00 Load Duration:1.25 Spacing: 24.0 " 3-15 16" Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: not in 4.50 GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Lt Slider: 2x6 SP #2; block length = 2.750' Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 60 0.00 5.00 Apply purins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. 12 C A 7i r Ln r r SEAT PLATE REQ. 1'6" --- 5' Code / Misc Criteria Defl/CSI Criteria ♦ Maximum Reactions (Ibs) Code:FBC 7th Ed. 2020 Res. PP Deflection in loc Udefi U# Gravity Non -Gravity TPI Sid: 2014 VERT(LL): -0.040 B 962 360 Loc R+ / R- / Rh / Rw / U / RL E 316 /- /- /233 /148 /122 Rep Factors Used: Yes VERT(CL): 0.032 B 999 240 FT/RT:10(0)/10(10) HORZ(LL): -0.026 B - - D 52 /- /- 128 /- Plate Type(s): HORZ(TL): 0.029 B - - C 76 !- /- 125 /100 /- WAVE Creep Factor: 2.0 Wind reactions based on MWFRS Max TC CSI: 0.576 E Brg Width = 8.0 Min Req = 1.5 Max BC CSI: 0.235 D Brg Width = 1.5 Min Req = - Max Web CSI: 0.190 C Brg Width = 1.5 Min Req = - Bearing E is a rigid surface. Wgt: 21.7 Ibs Bearing E requires a seat plate. Maximum Top Chord Forces Per Ply (Ibs) VIEW Ver. 20.01.01A.0724.12 Chords Tens.Comp. Chords Tens. Comp. A - B 381 - 936 B - C 24 - 90 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. E- D 0 0 A- E 993 - 335 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. E - B 908 -411 w "WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin Ryan Bays, P.E. responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owners authorized agent or the Building Designer, In the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field t191231 use of the Truss, Including handling, storage, Installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lude Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss. Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties Involved. The Specialty Engineer Is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI.1. Cnovrinht ® 201e A-1 Rmf Tn— - RRnrodipdon of thin dnmimant, in anv In— N nmhihfted withmit thn written nwmicdm of A-1 Rmf Tru— Job CHHS3B Truss CR Truss Type JACK 4 I Ply 102/09/2021 2601 Loading Criteria (psf) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 40.00 NCBCLL: 10.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: not in 4.50 GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Lt Slider: 2x6 SP #2; block length = 2.750' Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 75 0.00 7.00 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. SEAT PLATE REQ. 7' C T to 1 Code / Misc Criteria Defl/CSI Criteria ♦ Maximum Reactions (Ibs) Code: FBC 7th Ed. 2020 Res. PP Deflection in loc L/defl L/# Gravity Non -Gravity TPI Std: 2014 VERT(LL): -0.121 B 516 360 Loc R+ / R- / Rh / Rw / U / RL E 381 /- /- /264 /188 /172 Rep Factors Used: Yes VERT(CL): 0.115 B 545 240 FT/RT:10(0)/10(10) HORZ(LL): -0.084 B - - D 92 /- A 150 /4 /- Plate Type(s): HORZ(TL): 0.094 B - - C 137 /- /- /52 /163 /- WAVE Creep Factor: 2.0 Wind reactions based on MWFRS Max TC CSI: 0.850 E Brg Width = 8.0 Min Req = 1.5 Max BC CSI: 0.498 D Brg Width = 1.5 Min Req = - Max Web CSI: 0.255 C Brg Width = 1.5 Min Req = - Bearing E is a rigid surface. Wgt: 27.3 Ibs Bearing E requires a seat plate. Maximum Top Chord Forces Per Ply (Ibs) VIEW Ver: 20.01.01A.0724.12 Chords Tens.Comp. Chords Tens. Comp. A-B 475 -1214 B-C 43 -136 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. E- D 0 0 A- E 1257 -429 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. E - B 1156 - 529 —WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineedn responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Ryan Bays, P.E. responsibility of the Owner, the Owners authorized agent or the Building Designer, In the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field # 91231 use of the Truss, Including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out In the TDD and the practices and . 4451 St. Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon In writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. (•.nnvrioht n 201a A-1 R—f To— — Rnnr M dine of this dos -Ant. In anv fnnn, is nmhlhited withrnit the written nr."nissinn of A-1 Roof Tniss— Job CHHS3B Loading Criteria (psf) TOLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 40.00 NCBCLL: 10.00 Load Duration: 1.25 Spacing: 24.0 " Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Lt Wedge: 2x6 SP #2; Special Loads Truss Truss Type HJ5 I HIP_ 70# 4 _ __ 12 SEAT PLATE REQ. �-- 2-0-11/16" -3m+ 9'1-9/16" Qty Ply 02/09/2021 2 1 152# 2'0-3/16" - �{ B T fV 1 f - 1'5-1 /2" --�- 2'9-15/16"- 2'9-15/16" 42# 75# 104# Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: not in 4.50 GCpi: 0.18 Wind Duration: 1.60 -(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25) TC: From 2 pif at 0.00 to 2 plf at 9.13 BC: From 2 pif at 0.00 to 2 pif at 9.13 TC: 70 lb Conc. Load at 1.46 TC: -38 Ib Conc. Load at 4.29 TC: 152 lb Conc. Load at 7.12 BC: 42 lb Conc. Load at 1.46 BC: -75 lb Conc. Load at 4.29 BC: 104 lb Conc. Load at 7.12 Purlins In lieu of structural panels or rigid ceiling use puriins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 75 0.00 9.13 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads and reactions based on MWFRS. Wind loading based on both gable and hip roof types. 2606 i Code / Misc Criteria Defi/CSI Criteria ♦ Maximum Reactions (Ibs) Code: FBC 7th Ed. 2020 Res. PP Deflection in loc Udefl U# Gravity Non -Gravity TPI Sid: 2014 VERT(LL): -0.062 C 999 360 Loc R+ / R- / Rh / Rw / U / RL A 382 P P P 1371 P Rep Factors Used: Varies by Ld C s`tRT(CL): -0.064 C 999 240 FT/RT:10(0)/10(10) HORZ(LL): -0.083 C - - C 109 /- /- P /48 P Plate Type(s): HORZ(TL): 0.084 C - - B 85 P P /- /156 P WAVE Creep Factor: 2.0 Wind reactions based on MWFRS Max TC CSI: 0.704 A Brg Width = 11.3 Min Req = 1.5 Max BC CSI: 0.626 C Brg Width = 1.5 Min Req = - Max Web CSI: 0.000 B Brg Width = 1.5 Min Req = - Bearing A is a rigid surface. Wgt: 32.2 Ibs Bearing A requires a seat plate. 11 Maximum Top Chord Forces Per Ply (Ibs) VIEW Ver. 20.01.01A.0724.12 Chords Tens.Comp. A - B 43 - 35 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. A-C 0 0 -WARNING- Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TOD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineeringBan Ryan Bays, P.E. responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owners authorized agent or the Building Designer, In the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field 11191231 use of the Truss, Including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties Involved. The Specialty Engineer Is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined In TPI-1. Clmvdnht 0 2016 A-1 RmiTn­ - R-duallnn of this dm,ment. in anv fmm. is nrnhihtled withnut the written nemii cinn of A-1 RM!"rni vu. Job CHHS3B Loading Criteria (psf) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 40.00 NC13CLL: 10.00 Load Duration: 1.25 Spacing: 24.0 " Truss Truss Type HJ8 HIP_ 70 + -38#+ 3I5 SEAT PLATE REQ. 2'0-11 /16" -{ uty I y I UZ/UW;eUZ1 2 1 152# 273# + 2'0-3/16"--{ D 1'1'11-1/2" . I 1'5-1l2" 2'9-15/16 2915/16" 2915/16° 42# 104# Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C Kzt• NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: not in 4.50 GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP M-30; Webs: 2x4 SP #3; Lt Slider. 2x6 SP #2; block length = 3.889' Special Loads -(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25) TC: From 2 plf at 0.00 to 2 plf at 11.96 BC: From 2 plf at 0.00 to 2 plf at 11.96 TC: 70 lb Conc. Load at 1.46 TC: -38 lb Conc. Load at 4.29 TC: 152 lb Conc. Load at 7.12 TC: 273 lb Conc. Load at 9.94 BC: 42 lb Conc. Load at 1.46 BC: -75 lb Conc. Load at 4.29 BC: 104 lb Conc. Load at 7.12 BC: 184 lb Conc. Load at 9.94 Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 93 0.00 11.96 Apply purins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads and reactions based on MWFRS. Wind loading based on both gable and hip roof types. Code / Misc Criteria Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Factors Used: Varies by Ld FT/RT:10(0)/10(10) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): -0.048 C 999 361 VERT(CL): 0.054 C 999 241 HORZ(LL): -0.010 B - - HORZ(TL): 0.019 B - - Creep Factor. 2.0 Max TC CSI: 0.970 Max BC CSI: 0.989 Max Web CSI: 0.311 Wgt: 53.2 Ibs VIEW Ver. 20.01.01A.0724.12 T it I? 1 2607 ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ /R- /Rh /Rw /U /RL G 451 /- /- P /493 P E 300 P /- P /223 P D 174 /- /- P /187 P Wind reactions based on MWFRS G Brg Width = 11.3 Min Req = 1.5 E Brg Width = 1.5 Min Req = - D Brg Width = 1.5 Min Req = - Bearing G is a rigid surface. Bearing G requires a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A-B 133 -214 C-D 76 -60 B - C 731 -482 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. G- F 465 - 723 F- E 0 0 A - G 204 -120 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. G - B 655 -280 C - F 753 -485 -WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form. Verify design parameters and read notes on this Truss Design Drawing (Too) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TOD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specially Engineer), the seal on any TDD represents an acceptance of the professional engineerin responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Ryan Bays, , P.E. responsibility of the Owner, the Owners authorized agent or the Building Designer, In the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any geld use of the Truss, Including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out In the TDD and the practices and 4451 St Lune Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon In writing by all parties Involved. The Specialty Engineer Is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. C daht 0 MIR A-1 Roof Tm. cna - RonrMnrdino of thin d-rmnnt. In anv farm, is nmhihkrtl withnut thn writtnn rw.nninsion of A-1 Roof Tnrrcnc. JVV CHHS3B I IURS R I russ I ype Uty I Fly U21U9/2UZ1 EJAC 17 1 2603 Loading Criteria (psf) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 40.00 NCBCLL: 10.00 Load Duration: 1.25 Spacing: 24.0 " 3-15 16" SEAT PLATE REQ. f - - 1'6" ----� I- 6'6" Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: not in 4.50 GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Lt Slider: 2x6 SP #2; block length = 2.750' Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 75 0.00 6.50 Apply purins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. C 11 LO u; Code / Misc Criteria Defl/CSI Criteria ♦ Maximum Reactions (Ibs) Code: FBC 7th Ed. 2020 Res. PP Deflection in loc Udefl L/# Gravity Non -Gravity TPI Std: 2014 VERT(LL): -0.096 B 589 360 Loc R+ / R- / Rh / Rw / U / RL Rep Factors Used: Yes VERT(CL): 0.087 B 647 240 E 364 P P /255 /177 /159 FT/RT:10(0)/10(10) HORZ(LL): -0.066 B - - D 82 P /- /45 /4 /- Plate Type(s): HORZ(TL): 0.074 B - - C 122 P P /45 /147 P WAVE Creep Factor: 2.0 Wind reactions based on MWFRS Max TIC CSI: 0.718 E Brg Width = 8.0 Min Req = 1.5 Max BC CSI: 0.413 D Brg Width = 1.5 Min Req = - Max Web CSI: 0.238 C Brg Width = 1.5 Min Req = - Bearing E is a rigid surface. Wgt: 25.9 Ibs Bearing E requires a seat plate. Maximum Top Chord Forces Per Ply (Ibs) VIEW Ver. 20.01.01A.0724.12 Chords Tens.Comp. Chords Tens. Comp. A - B 449 -1142 B - C 38 -126 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. E-D 0 0 A-E 1190 -403 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. E - B 1091 -497 "WARNING- Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Enginaedng (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building Is the Ryan Bays, P.E. responsibility of the Owner, the Owner's authorized agent or the Building Designer, In the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field # 91231 use of the Truss, Including handling, storage. Installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out In the TDD and the practices and 4451 St Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon In writing by all parties Involved. The Specialty Engineer Is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined In TPI.1. C —riaht n 401E A-1 Rnnf T.-- Ren.MefJinn of thic dnn'ment. in — I— i." omhihifed with.d the written nnnni dnn of A-1 Roof Tmr ann. Job CHHS3B Truss I cuss I ype city, rly J8 EJAC 11 1 UY/UU/ZUZ7 2604 Loading Criteria (psf) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 40.00 NCBCLL: 10.00 Load Duration: 1.25 Spacing: 24.0 " T 3-15/16- SEAT PLATE REQ. �-- 1'6" Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: not in 4.50 GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord: 2x4 :SP 2400f-2.OE + SP M-31:; Bot chord: 2x4 :SP 2400f-2.0E + SP M-31:; Lt Slider: 2x6 SP #2; block length = 2.750' Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 75 0.00 8.50 Apply purins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. C co $'6n mi Code / Misc Criteria Defl/CSI Criteria ♦ Maximum Reactions (Ibs) Code: FBC 7th Ed. 2020 Res. PP Deflection in' loc Udefl L/# Gravity Non -Gravity TPI Std: 2014 VERT(LL): -0.166 B 485 360 Loc R+ / R- / Rh / Rw / U / RL E 437 /- /- /292 1220 /209 Rep Factors Used: Yes VERT(CL): 0.172 B 467 240 FT/RT:10(0)/10(10) HORZ(LL): -0.116 B - - D 122 /- P /66 /5 P Plate Type(s): HORZ(TL): 0.130 B - - C 181 P P [72 /210 1- WAVE Creep Factor: 2.0 Wind reactions based on MWFRS Max TC CSI: 0.592 E Brg Width = 8.0 Min Req = 1.5 Max BC CSI: 0.353 D Brg Width = 1.5 Min Req = - Max Web CSI: 0.298 C Brg Width = 1.5 Min Req = - Bearing E is a rigid surface. Wgt: 34.3 Ibs Bearing E requires a seat plate. Maximum Top Chord Forces Per Ply (Ibs) VIEW Ver. 20.01.01A.0724.12] Chords Tens.Comp. Chords Tens. Comp. A - B 581 -1470 B - C 57 -164 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. E- D 0 0 A- E 1494 - 531 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. E - B 1395 - 654 "WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise staled on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin Ryan Bays, P.E. responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building Is the q g1231 responsibility of the Owner, the Owner's authorized agent or the Building Designer, In the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, Including handling, storage. Installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon In writing by all parties involved. The Specialty Engineer Is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined In TPI-1. Cnnvriaht t0 2016 A-1 Roof To-- R—odiintion of this donimant. In anv form. Ls omhibilAd without tha writtnn rwrmissino of A-1 Roof Tnisses. CHHS3B I J8B 3.1Te- Iruss type (MONO 12 4 p 3X4 B AX6(C6 SEAT PLATE REQ. --1,6" 1- Loading Criteria (psi) Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-16 TCDL: 10.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II EXP: C Kzt: NA Des Ld: 40.00 Mean Height: 25.00 ft NCBCLL: 10.00 TCDL: 5.0 psf Load Duration: 1.25 BCDL: 5.0 psf Spacing: 24.0 " MWFRS Parallel Dist: h/2 to h C&C Dist a: 3.00 ft Loc. from endwall: not in 9.00 GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Webs: 2x4 SP #3; Lt Slider: 2x6 SP #2; block length = 2.750' Plating Notes All plates are 2X4(C6) except as noted. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 75 0.00 8.50 Apply purins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Wind loading based on both gable and hip roof types. 6'9-7/16" 8,6" ury rly I UZ/UV/ZUZI 1 1 2605 11� D III1.5X3 C 1112X4F SEAT PLATE REQ. V8-9/16" --� T io Fri i 1 Code / Misc Criteria Defl/CSI Criteria ♦ Maximum Reactions (Ibs), or •=PLF Code: FBC 7th Ed. 2020 Res. PP Deflection in loc Udefl U# Gravity Non -Gravity TPI Sid: 2014 VERT(LL): -0.055 B 999 360 Loc R+ / R- / Rh / Rw / U / RL G 350 /- % /245 /131 /148 Rep Factors Used: Yes VERT(CL): 0.070 B 857 240 FT/RT:10(0)/10(10) HORZ(LL): -0.038 B - - H' 56 P /- /29 129 /- Plate Type(s): HORZ(TL): 0.047 B - - Wind reactions based on MWFRS WAVE Creep Factor: 2.0 G Brg Width = 8.0 Min Req = 1.5 Max TC CSI: 0.557 H Brg Width = 76.0 Min Req = - Max BC CSI: 0.459 Bearings G & G are a rigid surface. Max Web CSI: 0.304 Bearings G & G require a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Wgt:37.1 Ibs Chords Tens.Comp. Chords Tens. Comp. VIEW Ver. 20.01.01 A.0724.12 A - B 432 -1049 C - D 0 -33 B - C 37 -204 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. G-F 10 -26 F-E 0 0 A - G 1091 - 385 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. G - B 924 -487 C - F 640 -254 -WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin Rya n Bays P.E. Bays, responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner's authorized agent or the Building Designer, In the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field91231 , # use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out In the TDD and the practices and 4451 St Lucle Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon In writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Glo—right 02mle A-1 Roof Tn ccaa— Ranrndiidi n of thN d—nonnt, in am in=. is nmhiNtnd withmit thn wrihan nannicdnn of A-1 RonfTri—s. Y I 10428/2020 HIP/ KING JACK (TYPICAL) STDL Ol .0 �= A-1 ROOF = TRU55E9 A FLORIDA CORPORATION A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 (772)409-1010 ATTACH END JACKS USING (4) 0.131" 0 TOENAILS ATTOP CHORD & (3) 0.131" O TOE NAILS AT BOTTOM CHORD. ATTACH KING JACK USING (3) 0.131" O TOE NAILS AT TOP CHORD & BOTTOM CHORD. ATTACH CORNER JACKS USING (2) 0.131" 0 TOE NAILS AT TOP & BOTTOM CHORDS (TYP). CORNERSET GENERAL SPECIFICATIONS: MAX LOAD: 55 PSF ROOF LOAD, 175 MPH, ASCE 7-10, EXP. B & C, UP TO 60' MEAN ROOF HEIGHT & EXPOSURE D UP TO 30' MEAN ROOF HEIGHT. Ryan Bays, P.E. # 91231 4451 St Lucie Blvd, Suile 201 Fort Pierce, FL 34946 5/28/2020 HIP/KING JACK (HVHZ) STDL "02.2's 'do#A-1 ROOF = TRU55E5 A FLORIDA CORPORATION A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL. 34946 (772)409-1010 ATTACH KING & END JACK WITH (1) THJA26 HANGER OR EQUIVALENT AT BOTTOM CHORD ATTACH KING & END JACKS WITH (1) LSTA12 TWIST STRAP AT TOP CHORD WITH (10) 1Od NAILS PER STRAP (MIN.) & (3) 0.131" 0 TOE NAILS. ATTACH CORNER JACKS & STD. JACKS WITH (1) LSTA12 TWIST STRAP AT TOP CHORD & BOTTOM CHORD WITH (10) 1 Od NAILS PER STRAP MINIMUM (TYP). HIGH VELOCITY HURRICANE ZONE CORNERSET SPECIFICATIONS: MAX LOAD: 55 PSF ROOF LOAD, 175 MPH, ASCE 7-10, EXP. B & C, UP TO 60'- MEAN ROOF HEIGHT & EXPOSURE D UP TO 30' MEAN ROOF HEIGHT. NOTE: IN ADDITION TO STRAPPING TOE- NAIL BOTH CHORDS OF CORNER JACKS TO CARRYING MEMBER PER THE FOLLOWING SCHEDULE: • 2X4: (2) 0.131" 0 TOE NAILS • 2X6: (3) 0.131" 0 TOE NAILS LSTA12 TWIST STRAP WITH 1 OD NAILS, MIN. (10). SEE MFR'S RECOMMENDED CONNECTION. HIP, OR KING JACK (TYP.) JACK, OR CORNER JACK (TYP.) IMPORTANT NOTE: CONNECTION DESIGNED IN ACCORDANCE WITH FBC 2321.6- 2321.7 PROVIDING METAL STRAPPING (FLORIDA APPROVED PRODUCT) TO RESIST MIN. 700LB UPLIFT AT ALL CONNECTIONS IN HIGH VELOCITY HURRICANE ZONE. Ryan Bays, P.E. 1t 91231 4451 St Lucie Blvd, Suite 201 Fort Pierce, FL 34946 -FEBRUARY 17, 2017 I ALTERNATE GABLE END BRACING DETAIL I STDTL03 I l is is �i Ci A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772.409-1010 ALTERNATE DIAGONAL BRACING TO THE BOTTOM CHORD V - 3' MAX. DIAL. BRACE AT 1/3 POINTS IF NEEDED IT IS THE RESPONSIBILITY OF THE BLDG. DESIGNER OR THE PROJECT ENGINEER/ARCHITECT TO DESIGN THE CEILING DIAPHRAGM AND ITS ATTACHMENT TO THE TRUSSES TO RESIST ALL OUT OF PLANE LOADS THAT MAY RESULT FROM THE BRACING OF THE GABLE ENDS. HORIZONTAL BRACE (SEE SECTION A -A) TRUSSSES L r 24' O.C. 2X6 DIAGONAL BRACE SPACED 48' O.C. ATTACHED TO VERTICAL WITH (4) - 16d NAILS, AND ATTACHED TO BLOCKING WITH (5) - 10d COMMONS. NAIL DIAGONAL BRACE TO PURLIN WITH TWO 16d NAILS. 2X4 PURLIN FASTENED TO FOUR TRUSSES WITH (2) - 16d NAILS EACH. FASTEN PURLIN TO BLOCKING W/ (2) - 16d NAILS (MINJ. ' PROVIDE 2X4 BLOCKING BETWEEN THE TRUSSES SUPPORTING THE \BRACE AND THE TWO TRUSSES ON \ EITHER SIDE AS NOTED. TOENAIL \ BLOCKING TO TRUSSES WITH (2) - \ 10d NAILS AT EACH END. ATTACH DIAGONAL BRACE TO BLOCKING WITH (5) - 10d COMMON WIRE NAILS. END WALL CEILING SHEATHING BRACING REQUIREMENTS FOR STRUCTURAL GABLE TRUSSES STRUCTURAL GABLE TRUSSES MAY BE BRACED AS NOTED: METHOD 1: ATTACH A MATCHING GABLE TRUSS TO THE INSIDE FACE OF THE STRUCTURAL GABLE AND FASTEN PER THE FOLLOWING' NAIL SCHEDULE. METHOD 2: ATTACH 2X_ SCABS TO THE FACE OF EACH VERTICAL MEMBER ON THE STRUCTURAL GABLE PER.THE FOLLOWING NAILING SCHEDULE. SCABS ARE TO BE OF THE SAME SCAB ALONG SIZE, GRADE, AND SPECIES AS THE TRUSS VERTICALS. VERTICAL NAILING SCHEDULE: - FOR WIND SPEEDS 120 MPH (ASCE 7-98, 02, 05), 150 MPH (ASCE 7-10) OR LESS, NAIL ALL MEMBERS WITH ONE ROW OF 10d (.131' X 3') NAILS SPACED 6' O.C. - FOR WIND SPEEDS GREATER 120 MPH (ASCE 7-9B, 02, 05), 150 MPH (ASCE 7-10) NAIL ALL MEMBERS WITH TWO ROWS OF 10d (131'X3') NAILS SPACED . 6' O.C. (2X4 STUDS MINIMUM). STRUCTURAL GABLE TRUSS. MAXIMUM STUD LENGTHS ARE LISTED ON PAGE 1. ALI BRACING METHODS SHOWN ON PAGE 1 ARE VALID AND ARE TO BE FASTENED TO THE SCABS OR VERTICAL STUDS OF THE STANDARD GABLE TRUSS ON THE INTERIOR SIDE OF THE STRUCTURE. NOTE: THIS DETAIL IS TO BE USED ONLY FOR STRUCTURAL GABLES WITH INLAYED / STUDS. TRUSSES WITHOUT INLAYED \S ARE NOT ADDRESSED HERE. / STANDARD GABLE / \ SS / UKAL TRUSS .. �.. STUD AN ADEQUATE DIAPHRAGM OR OTHER METHOD OF BRACING MUST BE PRESENT TO PROVIDE FULL LATERAL SUPPORT OF THE BOTTOM,CHORO TO RESIST ALL OUT OF PLANE LOADS. THE BRACING SHOWN IN THIS DETAIL IS FOR VERTICAL/STUDS ONLY. Ryan Bays, P.E. # 91231 4451 St. Lucie Blvd, Suite 201 Fort Pierce, FL 34946 12/23/19 PIGGY -BACK TRUSS STDII'1�O4.1 A A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772409-1010 PIGGY -BACK DETAIL (TYPICAL) 180 MPH WIND, 30.00 FT MEAN ROOF HEIGHT, A.S.C.E. 7-10, PARTIALLY ENCLOSED BLDG. LOCATED ANYWHERE AT ROOF, EXPOSURE C, WIND D.L.= 5.0 P.S.F. (MIN.), KZT= 1.00. OR... 160 MPH WIND, 30.00 FT MEAN ROOF HEIGHT, A.S.C.E. 7-10, PARTIALLY ENCLOSED BLDG. LOCATED ANYWHERE AT ROOF, EXPOSURE D, WIND D.L.= 5.0 P.S.F. (MIN.), KZT= 1.00. IMPORTANT NOTE: TOP CHORDS OF TRUSSES SUPPORTING PIGGY -BACK CAP TRUSSES MUST BE ADEQUATELY BRACED BY SHEATHING AND/ OR PURLINS. THE BUILDING ENGINEER OF RECORD SHALL PROVIDE DIAGONAL BRACING OR OTHER SUITABLE ANCHORAGE TO PERMANENTLY RESTRAIN PURLINS AND LATERAL BRACING FOR OUT OF PLANE LOADS OVER GABLE ENDS. MAXIMUM TRUSS SPACING IS NOT TO EXCEED 24" O.C. DETAIL IS NOT APPLICABLE IF CAP SUPPORTS ADDITIONAL LOADS SUCH AS CUPOLA, STEEPLE, CHIMNEY OR DRAG STRUT LOADS. **REFER TO ENGINEER'S SEALED TRUSS DESIGN DRAWINGS FOR PIGGY -BACK AND BASE TRUSS SPECIFICATIONS.** PIGGY -BACK TRUSS. (REFER TO ACTUAL TRUSS DESIGN DRAWINGS FOR ADDITIONAL INFORMATION.) 2'-0" MAX OPTION NO. 1 - TEE-LOK 3" x 8" TEE-LOK MULTI -USE CONNECTION PLATES SPACED AT 4'-0" O.C. MAX. PLATES SHALL BE PRESSED INTO PIGGY -BACK TRUSS AT 4'-0" O.C. STAGGERED FROM EACH FACE AND NAILED TO BASE TRUSS WITH 4 EACH 6d (1.5" X 0.099") NAILS IN EACH PLATE TO ACHEIVE MAXIMUM UPLIFT CAPACITY OF 377 LBS AT EACH 3" X 8" TEE-LOK MULTI -USE CONNECTION PLATE (MINIMUM OF 2 PLATES). OPTION NO.2 - APA RATED GUSSET: 8" x 8" x 0-7/16" (MIN.) APA RATED SHEATHING GUSSETS EACH FACE. ATTACH AT 8'-0" O.C. w/ 8 (EACH) 6d COMMON (0.113" x 2") NAILS PER GUSSET: 4 (EACH) AT CAP BOTTOM CHORD & 4 (EACH) AT BASE TRUSS TOP CHORD. GUSSETS MAY BE STAGGERED AT 4'-0" O.C. FRONT TO BACK FACES. MINIMUM TWO (2 EA.) CONNECTIONS AT EACH TRUSS. OPTION NO.3 - 2X4 VERTICAL WOOD SCAB: 2X4 SPF #2, FULL CHORD DEPTH SCABS AT EACH FACE. ATTACH AT 8'-0" O.C. w/6 (EACH) 1 Od BOX NAILS (0.128" x 3") PER SCAB: 3 (EACH) AT CAP BOTTOM CHORD AND 3 (EACH) AT BASE TRUSS TOP CHORD. SCABS MAY BE STAGGERED 4'-0" O.C. FRONT TO BACK FACES. MINIMUM TWO (2 EA.) CONNECTIONS AT EACH TRUSS. OPTION #1: TEE-LOK MULTI -USE CONNECTION PLATE. OPTION #2: APA RATED GUSSET. OPTION #3: 2X4 VERT. SCAB. ATTACH EACH PURLIN TO TOP CHORD OF BASE TRUSS. PURLIN & CONNECTIONS BY OTHERS. BASE TRUSS. (REFER TO TRUSS DESIGN DRAWINGS FOR ADDITIONAL INFORMATION.) PURLINS SPACED ACCORDING TO MAX. SPACING OF TOP CHORD OF BASE TRUSS. SPACING IS NOT TO EXCEED 24" O.C. & PURLINS TO BE LOCATED AT JOINT OF EACH BASE TRUSS. ** IMPORTANT NOTE ** THIS DETAIL IS VALID ONLY FOR SINGLE PLY BASE TRUSSES SPACED AT 24" O.C. OR LESS. Ryan Bays, P.E. # 91231 4451 St Lucie Blvd, Suite 201 Fart Pierce, FL 34946 JULY 17, 2017 TRUSSED VALLEY SET DETAIL - SHEATHED I STDTL05 A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772 409.1010 VALLEY TRUSS (TYPICAL) SECURE VALLEY TRUSS W/ ONE ROW OF 10d NAILS 6" O.C. GENERAL SPECIFICATIONS: 1. NAIL SIZE = 3" X 0.131" = 10d 2. WOOD SCREW = 4.5" SDS25412 SIMPSON OR EQUIVALENT. 3. INSTALL SHEATHING TO TOP CHORD OF BASE TRUSSES. 4. INSTALL VALLEY TRUSSES (24" O.C. MAXIMUM) AND SECURE TO BASE TRUSSES AS PER DETAIL "A". 5. BRACE VALLEY WEBS IN ACCORDANCE WITH THE INDIVIDUAL DESIGN DRAWINGS. 6. NAILING DONE PER NDS - 01. GABLE END, COMMON 7. VALLEY STUD SPACING NOT TO EXCEED 48" O.C. TRUSS, OR GIRDER TRUSS DETAIL A BASETRUSSES -C CIVU, L,VMMVIV 3S, OR GIRDER TRUSS TRUSS CRITERIA: WIND DESIGN PER ASCE 7-98, ASCE 7-02, ASCE 7-05: 146 MPH WIND DESIGN PER ASCE 7-10: 170 MPH MAX MEAN ROOF HEIGHT = 30 FEET ROOF PITCH = MINIMUM 3/12 MAXIMUM 6/12 CATERGORY II BUILDING EXPOSURE C WIND DURATION OF LOAD INCREASE: 1.60 MAX TOP CHORD TOTAL LOAD = 50 PSF ATTACH 2X4 CONTINUOUS #2 MAX SPACING = 24" O.C. (BASE AND VALLEY) SYP TO THE ROOF W/ TWO MINIMUM REDUCED DEAD LOAD OF 6 PSF ON THE TRUSSES. SIMPSON SDS25412 (1/4" X 4.5") OR EQUIVALENT WOOD SCREWS INTO EACH BASE TRUSS. Ryan Bays, P.E. # 91231 4451 St. Lucie Blvd, Suite 201 Fort Pierce, FL 34946 FEBRUARY 5, 2018 I TRUSSED VALLEY SET DETAIL I STDTL06' GENERAL SPECIFICATIONS: rrI - 1. NAIL SIZE = 3" X 0.131" = 10d �! 2. WOOD SCREW = 3" SDS25300 SIMPSON OR EQUIVALENT. 3. INSTALL VALLEY TRUSSES (24" O.C. MAXIMUM) AND SECURE PER DETAIL �- �I 4. BRACE VALLEY WEBS IN ACCORDANCE WITH THE INDIVIUAL DESIGN DRAWINGS. 5. BASE TRUSS SHALL BE DESIGNED WITH A PURLIN SPACING EQUIVALENT A-i ROOF TRUSSES TO THE RAKE DIMENSION OF THE VALLEY TRUSS SPACING. 6. NAILING DONE PER NDS - 01. 4451 ST. LUCIE BLVD. GABLE END, COMMON 7. VALLEY STUD SPACING NOT TO EXCEED 48" O.C. FORT PIERCE, FL 34946 TRUSS, OR GIRDER 772409-1010 TRUSS SECURE W/( VALLE(TYPICAL) I� II �� II II II IIASET 11 TRUSSES (NO SHEATHING) N.T.S. GABLE END, COMMON TRUSS, OR GIRDER P r2 VALLEY TRUSS TRUSS (TYPICAL) SEE DETAIL "A" BELOW (TYP.) WIND DESIGN PER ASCE 7-98, ASCE 7-02, ASCE 7-05: 146 MPH WIND DESIGN PER ASCE 7-10: 170 MPH MAX MEAN ROOF HEIGHT = 30 FEET ROOF PITCH = MINIMUM 3/12 MAXIMUM 6/12 CATERGORY II BUILDING EXPOSURE C WIND DURATION OF LOAD INCREASE: 1.60 ATTACH 2X4 CONTINUOUS #2 MAX TOP CHORD TOTAL LOAD = 50 PSF SYP TO THE ROOF W/ TWO MAX SPACING = 24" O.C. (BASE AND VALLEY) SIMPSON SDS25300 (1/4" X 3") MINIMUM REDUCED DEAD LOAD OF 6 PSF ON THE TRUSSES. OR EQUIVALENT WOOD SCREWS INTO EACH BASE TRUSS. Ryan Bays, P.E. # 91231 4451 St. Lucie Blvd, Suite 201 Fort Pierce, FL 34946 J U LY 17, 2017 If. (HIGH WIND VELOCITY) ^�L STDTL07 A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772-409-1010 ATTAC WIND DESIGN PER ASCE 7-98, ASCE 7-1 WIND DESIGN PER ASCE 7-10: 170 MPE MAX MEAN ROOF HEIGHT = 30 FEET CATERGORY II BUILDING EXPOSURE B OR C WIND DURATION OF LOAD INCREASE: MAX TOP CHORD TOTAL LOAD = 50 PSE MAX SPACING = 24" O.C. (BASE AND VA SUPPORTING TRUSSES DIRECTLY UNDcK VMLL=T 1 KUJJCJ 11AUJ 1 cc DESIGNED WITH A MAXIMUM UNBRACED LENGTH OF 2'.- 10" ON AFFECTED TOP CHORDS. NOTES: 1. SHEATHING APPLIED AFTER INSTALLATION OF VALLEY TRUSSES. 2. THIS DETAIL IS NOT APPLICABLE FOR SPF-S SPECIES LUMBER. NON -BEVELED BOTTOM CHORD r FOR BEVELED BOTTOM CHORD, CLIP MAY BE APPLIED } TO EITHER FACE. CLIP MAY BE APPLIED TO THIS FACE UP TO A MAXIMUM 6/12 PITCH FBI CLIP MUST BE APPLIE THIS FACE WHEN I EXCEEDS 6/12 (MAX 12/12 PITCH) Ryan Bays, P.E. # 91231 4451 St Lucie Blvd, Suite 201 Fort Pierce, FL 34946 FEBRUARY 17, 2017 1 STANDARD GABLE END DETAIL I STDTL08 A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772-409-1010 TYPICAL 2X4 L-BRACE NAILED TO 2X4 VERTICALS 7z; VERT STUD SECTION B-B TRUSS GEOMETRY AND CONDITIONS SHOWN ARE FOR ILLUSTRATION ONLY. VERTICAL 2X6 SP OR SPF STUD #2 DIAGONAL BRACE (4) - 16d , NAILS 16d NAILS SPACED 6' -D.C. (2) 10d NAILS INTO 2X6 2X6 SP OR' SPF #2 2X4 SP OR SPF #2 TYPICAL HORIZONTAL BRACE NAILED TO 2X4 VERTICALS SECTION A -A W/(4) - 10d NAILS DIAGONAL BRACE 4' - 0' O.C. MAX. SEE INDIVIDUAL ENGINEERING DRAWINGS FOR TRUSS DESIGN CRITERIA. 12 PROVIDE 2X4 BLOCKING BETWEEN Q VARIES TO COMMON TRUSS THE FIRST TWO TRUSSES AS NOTED. TOENAIL BLOCKING TO TRUSSES * WITH (2) - 10d NAILS AT EACH END. ATTACH DIAGONAL BRACE TO BLOCKING WITH (5) - 10d NAILS ** (4) 8d NAILS MINIMUM, ROOF 3X4= B PLYWOOD SHEATHING TO SHEATHING 2X4 STD SPF BLOCK * DIAGONAL BRACING ** L - BRACING REFER / REFER TO SECTION A -A TO SECTION B-B 24' MAX. NOTE:. / MINIMUM GRADE OF #2 MATERIAL IN THETOP lOd CONNECTION BETWEEN BOTTOM CHORD OF G BLE ENDAND TRBOTTOM RUSS AND WALL TO 12' AILS BE PROVIDED BY PROJECT ENGINEER OR ARCHITECT. 3. BRACING SHOWN IS FOR INDIVIDUAL TRUSS ONLY. CONSULT SLOG. --, ARCHITECT OR ENGINEER FOR TEMPORARY AND PERMANENT BRACING OF ROOF SYSTEM. / 4. 'L' BRACES SPECIFIED ARE TO BE FULL LENGTH, SPF OR SP #3 OR BETTER WITH ONE ROW OF 10d NAILS SPACED 6. O.C. / TRUSSES B 24' O.C. S. DIAGONAL BRACE TO BE APPROXIMATELY 45 DEGREES TO ROOF DIAPHRAGM AT4'-0'D.C. S. CONSTRUCT HORIZONTAL BRACE CONNECTING A 2X6 AND A 2X4 AS SHOWN 2X6 DIAGONAL BRACE WITH 16d NAILS SPACED 6' O.C. HORIZONTAL BRACE TO BE LOCATED AT SPACED 48' O.C. ATTACHED THE MIDSPAN OF THE LONGEST GABLE STUD. ATTACH TO VERTICAL GABLE __ TO VERTICAL WITH (4).- STUDS WITH (3) 10d NAILS THROUGH 2X4 (REFER TO SECTION A -A) ;' 16d NAILS, AND ATTACHED 7. GABLE STUD DEFLECTION MEETS OR EXCEEEDS L/240. TO BLOCKING WITH (5) - B. THIS DETAIL DOES NOT APPLY TO STRUCTURAL GABLES. DIAG. BRACE 10d NAILS. 9. DO NOT USE FLAT BOTTOM CHORD GABLES NEXT TO SCISSOR TYPE AT 1/3 POINTS TRUSSES. IF NEEDED 10.10d AND 16d NAILS ARE 0131'X3.0' AND 0131'X3.5' COMMON WIRE NAILS HORIZONTAL BRACE RESPECTIVELY. (SEE SECTION A -A) 11. SOUTHERN PINE LUMBER DESIGN VALUES ARE THOSE EFFECTIVE 06-01-12 BY SPIB/ALSC. MINIMUM STUD SIZE SPECIES AND GRADE STUD SPACING WITHOUT BRACE 2X4 L - BRACE DIAGONAL BRACE (2) DIAGONAL BRACES AT 1/3 POINTS MAXIMUM STUD LENGTH 2X4 SP #31 STUD 12" O.C. 3-8-10 R-11 6-6.11 11-1-13 2X4 SP 43 / STUD I 16" O,C. 3.3-10 4-9-12 6-6-11 9-10.15 2X4 SP #31 STUD 24" O.C. 248 6 3-11-3 5-4-12 8.1-2 2X4SP#2 12"O.C. 3-10-15 5-6-11 6-6-11 11-8-14 2X4 SP #2 16" O.C. 3-6-11 4-9-12 6-6-11 10-8-0 2X4 SP 42 24" O.C. 1 3-14 1 3-11-3 1 6-2-9 1 9-3-13 DIAGONAL BRACES OVER 6' - 3' REQUIRE A 2X4 T-BRACE ATTACHED TO ONE EDGE. DIAGONAL BRACES OVER 12' - 6' REQUIRE 2X4 I -BRACES ATTACHED TO BOTH EDGES. FASTEN T AND I BRACES TO NARROW EDGE OF DIAGONAL BRACE WITH 10d NAILS G' O.C., WITH 3' MINIMUM END DISTANCE. BRACE MUST COVER 90% OF DIAGONAL LENGTH. T OR I BRACES MUST BE 2X4 SPF #2 OR SP #2. MAX MEAN ROOF HEIGHT = 30 FEET EXPOSURE B OR C ASCE 7-10 190 MPH STUD DESIGN IS BASED ON COMPONENTS AND CLADDING. DURATION OF LOAD INCREASE :1.60 CONNECTION OF BRACING IS BASED ON MWFRS. END WALL Ryan Bays, P.E. # 91231 4451 St. Lucie Blvd, Suite 201 Fort Pierce, FL 34946 'X T-BRACE / I -BRACE DETAIL FEBRUARY 17, 2017 STDTL09 WITH 2X BRACE ONLY NOTES: T—BRACING / I —BRACING TO BE USED WHEN CONTINUOUS LATERAL BRACING IS IMPRACTICAL. T—BRACE / I —BRACE MUST COVER 90% OF WEB LENGTH. THIS DETAIL NOT TO BE USED TO CONVERT T—BRACE / I —BRACE WEBS TO CONTINUOUS LATERAL BRACED WEBS. ........................ ...... _.-............. - A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772409-1010 NAILING PATTERN T-BRACE SIZE NAIL SIZE NAIL SPACING 2X4 OR 2X6 OR 2XB 10d 6' O.C. NOTE: NAIL ALONG ENTIRE LENGTH OF T—BRACE / I —BRACE (ON TWO—PLY TRUSSES NAIL TO BOTH PLIES) NAILS BRACE SIZE FOR ONE -PLY TRUSS SPECIFIED CONTINUOUS ROWS OF LATERAL BRACING WEB SIZE 1 2 2X3 OR 2X4 2X4 T—BRACE 2X4 I —BRACE 2X6 2X6 T—BRACE 2X6 I —BRACE 2X8 2XB T—BRACE 2X8 I —BRACE BRACE SIZE FOR TWO-PLY TRUSS SPECIFIED CONTINUOUS ROWS OF LATERAL BRACING WEB SIZE 1 2 2X3 OR 2X4 2X4 T—BRACE 2X4 I —BRACE 2X6 2X6 T—BRACE 2X6 I —BRACE 2X8 2X8 T—BRACE 2X8 I —BRACE T—BRACE / I —BRACE MUST BE SAME SPECIES AND GRADE (OR BETTER) AS WEB MEMBER. NAILS NAILS WEB NAILS WEB I -BRACE T-BRACE Ryan Bays, P.E. 491231 SECTION DETAIL 415Fed Pierce, F1L'34946201 FEBRUARY 17, 2017 LATERAL BRACING RECOMMENDATIONS I STDTL10 ?� L .°'I A-1 ROOF TRUSSES 4461 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772.409-1010 TO MINIMIZE VIBRATION COMMON TO ALL SHALLOW FRAMING SYSTEMS, 2X6 'STRONGBACK' IS RECOMMENDED, LOCATED EVERY B TO 10 FEET ALONG A FLOOR TRUSS. NOTE 1: 2X6 STRONGBACK ORIENTED VERTICALLY MAY BE POSITIONED DIRECTLY UNDER THE TOP CHORD OR DIRECTLY ABOVE THE BOTTOM CHORD, SECURELY FASTENED TO THE TRUSS USING ANY OF THE METHODS ILLUSTRATED BELOW. NOTE 2: STRONGBACK BRACING ALSO SATISFIES THE LATERAL BRACING REQUIREMENTS FOR THE BOTTOM CHORD OF THE TRUSS WHEN IT IS PLACED ON TOP OF THE BOTTOM CHORD, IS CONTINUOUS FROM END TO ENO, CONNECTED WITH A METHOD OTHER THAN METAL FRAMING ANCHOR, AND PROPERLY CONNECTED, BY OTHERS, AT THE ENDS. USE METAL FRAMING ANCHOR TO ATTACH TO TOP CHORD BLOCKING BEHIND THE VERTICAL WEB IS RECOMMENDED WHILE NAILING THE STRONGBACK INSERT WOOD SCREW THROUGH OUTSIDE FACE OF CHORD INTO EDGE OF STRONGBACK (DO NOT ATTACH TO VERTICAL ATTACH TO VERTICAL USE DRYWALL TYPE SCREWS) WEB WITH (3) - 10d SCAB WITH (3) - 10d NAILS (0.131' X 3') NAILS (0.131' X 3'). r ATTACH TO VERTICAL NIBLS(0131'X3) USE METAL FRAMING ATTACH TO VERTICAL ANCHOR TO ATTACH WEB WITH (3) - 10d TO BOTTOM CHORD NAILS (0131' X 3') ATTACH 2X4 VERTICAL TO FACE OF TRUSS. FASTEN TO TOP AND BOTTOM CHORD WITH (2) - 10d NAILS (0.131' X 3') IN EACH CHORD ATTACH TO VERTICAL SCAB WITH (3) - 10d NAILS (0.131' X 3') TRUSS f 2X6 4' - 0' WALL STRONGBACK (TYPICAL SPLICE) (BY OTHERS) ATTACH TO CHORD WITH (2) #12 X 3' WOOD SCREWS (0.216' DIAJ INSERT SCREW THROUGH OUTSIDE FACE OF CHORD INTO EDGE OF STRONGBACK (DO NOT USE DRYWALL TYPE SCREWS) THE STRONGBACKS SHALL BE SECURED AT THEIR ENDS TO AN ADEQUATE SUPPORT, DESIGNED BY OTHERS. IF SPLICING IS NECESSARY, USE A 4' - 0' LONG SCAB CENTERED ON THE SPLICE AND JOINED WITH (12) - 10d NAILS (0.131' X 3') EQUALLY SPACED. ALTERNATE METHOD OF SPLICING: OVERLAP STRDNGBACK MEMBERS A MINIMUM OF 4' - 0' AND FASTEN WITH (12) - 10d NAILS (0.131' X 3') STAGGERED AND EQUALLY SPACED (TO BE USED ONLY WHEN STRONGBACK IS NOT ALIGNED WITH A VERTICAL). BLOCKING (BY OTHERS) Ryan Bays, P.E. # 91231 4451 St. Lucie Blvd, Suite 201 Fort Pierce, FL 34946 FEBRUARY 17, 2017 LATERAL TOE -NAIL DETAIL STDTL11 A-1 ROOF TRUSSES 4451 ST_ LUCIE BLVD. FORT PIERCE, FL 34946 772-409-1010 NOTES: 1. TOE -NAILS SHALL BE DRIVEN AT AN ANGLE OF 45' WITH THE MEMBER AND MUST HAVE FULL WOOD SUPPORT (NAIL MUST BE DRIVEN THROUGH AND EXIT AT THE BACK CORNER OF THE MEMBER END AS SHOWN). 2. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE WOOD. 3. ALLOWABLE VALUE SHALL BE THE LESSER VALUE OF THE TWO SPECIES FOR MEMBERS OF DIFFERENT SPECIES. TOE -NAIL SINGLE SHEAR VALUES PER NOS 2001 (LB/NAIL) DIA SP OF HF SPF SPF-S .131 88.0 80.6 69.9 68.4 59.7 o.135 J 93.5 85.6 74.2 72.6 63.4 .162 108.8 99.6 86.4 84.5 73.8 in pi .128 74.2 67.9 58.9 57.6 50.3 0 Z 0 J .131 75.9 69.5 60.3 59.0 51.1 .148 81.4 74.5 64.6 63.2 52.5 in N IM VALUES SHOWN ARE CAPACITY PER TOE -NAIL. APPLICABLE DURATION OF LOAD INCREASES MAY BE APPLIED. EXAMPLE: (3) - 16d NAILS (0162' DIA. X 3.5') WITH SPF SPECIES BOTTOM CHORD FOR LOAD DURATION INCREASE OF 115: 3 (NAILS) X 84.5 (LB/NAIL) X 1.15 (DOL) = 291.5 LB MAXIMUM CAPACITY ANGLE MAY VARY FROM 30° TO SO* 45.00° ANGLE MAY VARY FROM 30" TO SO* THIS DETAIL IS ONLY APPLICABLE TO THE THREE END DETAILS SHOWN BELOW. SIDE VIEW (2X4) 3 NAILS NEAR SIDE NEAR SIDE NEAR SIDE 45.00° SIDE VIEW (2X6) 4 NAILS NEAR SIDE NEAR SIDE NEAR SIDE NEAR SIDE ]0° Z. �» a � o' wu o u, QUM 201 Fort Pierce, FL 34946 FEBRUARY 17, 2017 1 UPLIFT TOE -NAIL DETAIL I STDTL12 A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD, FORT PIERCE, FL 34946 772-409.1010 THIS DETAIL SHALL BE USED FOR A CONNECTION RESISITING UPLIFT FORCES ONLY. BUILDING DESIGNER IS RESPONSIBLE FOR LOADS IN OTHER DIRECTIONS. TOE -NAIL WITHDRAWAL VALUES PER NOS 2005 (LB/NAIL) DIA. SP OF HF SPF SPF-S 0 .131 59 46 32 30 20 Z O J .135 60 48 33 30 20 a U7 l'7 .162 72 58 39 37 25 J 2 (' .128 54 42 28 27 19 f— Z Z .131 55 43 29 28 19 W .148 62 48 34 31 21 J Lo J_ N Q M Z .120 51 39 27 26 17 Z .128 49 38 26 25 17 O .131 51 39 27 26 17 J .148 57 44 31 28 20 M NOTES: 1. TOE —NAILS SHALL BE DRIVEN AT AN ANGLE OF 30' WITH THE MEMBER AND STARTED 1/3 THE LENGTH OF THE NAIL FROM THE MEMBER END AS SHOWN. 2. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE WOOD. 3. ALLOWABLE VALUE SHALL BE BASED ON THE SPECIE WITH LOWER NAIL CAPACITY BETWEEN THE TWO MEMBERS IN THE CONNECTION. VALUES SHOWN ARE CAPACITY PER TOE —NAIL. APPLICABLE DURATION OF LOAD INCREASES MAY BE APPLIED. EXAMPLE: (3) — 16d NAILS (0162' DIA. X 3.5') WITH SPF SPECIES TOP PLATE FOR WIND DOL OF 1.33: 3 (NAILS) X 37 CLB/NAIL) X 1.33 COOL FOR WIND) = 148 LB MAXIMUM ALLOWABLE UPLIFT REACTION DUE TO WIND FOR WIND DOL OF 1.60: 3 (NAILS) X 37 (LB/NAIL) X 1.60 (DOL FOR WIND) = 177 LB MAXIMUM ALLOWABLE UPLIFT REACTION DUE TO WIND IF THE UPLIFT REACTION SPECIFIED ON THE TRUSS DESIGN DRAWING EXCEEOS 147 LBS (177 LBS) BUILDING DESIGNER IS RESPONSIBLE TO SPECIFY A DIFFERENT CONNECTION. rrr USE (3) TOE —NAILS ON 2X4 BEARING WALL rrr USE (4) TOE —NAILS ON 2X6 BEARING WALL NEAR SIDE FAR S: )E TOP PLATE OF WALL VIEWS SHOWN ARE FOR ILLUSTRATION PURPOSES ONLY IL NAIL NAIL .. 3ays, P.E. # 91231 4451 St. Lucie Blvd, Suite 201 Fort Pierce, FL 34946 SIDE VIEW END VIEW I E[�RdARY 5, 2016 I TYP 2x2 NAILER ATTACHMENT I STDTL13 w � A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772-409-1010 "1.5x4 a 2x2 NAILER ATTACHMENT GENERAL SPECIFICATIONS MAX LOAD: 55 psf Roof Load, 170 mph, ASCE 7-10, 29'-0" Mean Height, Exp. B, C or D. Ryan Bays, P.E. # 9123, 4451 St Lucie Blvd, Suite 201 Fort Pierce, FL 34946 April 11, 2016 TYPICAL ALTERNATE BRACING DETAIL FO EXTERIOR FLAT GIRDER TRUSS STDTL14 Q. A-1 ROOF TRUSSES 4451 ST..LUCIE BLVD. FORT PIERCE, FL 34946 772-409-1010 (4) 12d TRUSS 2411 O.C. UPLIFT CONNECTION (SEE ROOF TRUSS) EXTERIOR FLAT GIRDER 12 VARIES (4) 12d MAX 3011(2'-611) 2x6 #2 SP (Both Faces) 24" O.C. SIMPSON H5 Ryan Bays, P.E. # 91231 4451 St Lucie Blvd, Suite 201 Fort Pierce, FL 34946 n ", V I STANDARD REPAIR DETAIL FOR BROKEN CHORDS, WEBS, AND FEBRUARY 17, 2017 DAMAGED OR MISSING CHORD SPLICE PLATES STDTL15 A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772-409-1010 TOTAL NUMBER OF NAILS EACH SIDE OF BREAK X (INCHES) MAXIMUM FORCE (LBS) 15% LOAD DURATION SP. OF SPF HF 2X4 2X6 2X4 2X6 2X4 2X6 2X4 2X6 2X4 2X6 20 30 24" 1706 2559 1561 2342 1320 1980 1352 2028 26 39 30' 2194 3291 2007 3011 1697 2546 1738 2608 32 48 36' 2681 4022 2454 3681 2074 3111 2125 3187 38 57 42' 3169 4754 2900 4350 2451 3677 2511 3767 44 66 48' 3657 5485 3346 5019 2829 4243 2898 4347 rt DIVIDE EQUALLY FRONT AND BACK ATTACH 2X_ SCAB OF THE SAME SIZE AND GRADE AS THE BROKEN MEMBER TO EACH FACE OF THE TRUSS ( CENTER ON BREAK OR SPLICE) WITH 10d NAILS (TWO ROWS FOR 2X4. THREE ROWS FOR 2X6) SPACED 4' O.C. AS SHOWN (131' DIA. X 3'). STAGGER NAIL SPACING FROM FRONT FACE AND BACK FACE FOR A NET 2' O.C. SPACING IN THE MAIN MEMBER. USE A MIN. 3' MEMBER ENO DISTANCE. THE LENGTH OF THE BREAK (C) SHALL NOT EXCEED 12'. (C=PLATE LENGTH FOR SPLICE REPAIRS) THE MINIMUM OVERALL SCAB LENGTH REQUIRED (L) IS CALCULATED AS FOLLOWS: L = (2) X + C 'I BREAK •10d NAILS NEAR SIDE +10d NAILS FAR SIDE 6' MIN THE LOCATION OF THE BREAK MUST BE GREATER THE REQUIRED X DIMENSION FROM ANY PERIMETER AND A MINIMUM OF 6' FROM ANY INTERIOR JOINT 00 NOT USE REPAIR FOR JOINT SPLICES NOTES: 1. THIS REPAIR DETAIL IS TO BE USED ONLY FOR THE APPLICATION SHOWN. THIS REPAIR DOES NOT IMPLY THAT THE REMAINING PORTION OF THE TRUSS IS UNDAMAGED. THE ENTIRE TRUSS SHALL BE INSPECTED TO VERIFY THAT NO FURTHER REPAIRS ARE REQUIRED. WHEN THE REQUIRED REPAIRS ARE PROPERLY APPLIED, THE -TRUSS WILL BE CAPABLE OF SUPPORTING THE LOADS INDICATED. 2. ALL MEMBERS MUST BE RETURNED TO THEIR ORIGINAL POSITIONS BEFORE APPLYING REPAIR AND HELD IN PLACE DURING APPLICATION OF REPAIR. 3. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE WOOD. 4. WHEN NAILING THE SCABS, THE USE OF A BACKUP WEIGHT IS RECOMMENDED TO AVOID LOOSENING OF THE CONNECTOR PLATES AT THE JOINTS OR SPLICES. 5. THIS REPAIR IS TO BE USED FOR SINGLE PLY. TRUSSES IN THE 2X_ ORIENTATION ONLY. G. THIS REPAIR IS LIMITED TO TRUSSES WITH NO MORE THAN THREE BROKEN MEMBERS. TRUSS CONFIGURATION AND BREAK LOCATIONS FOR ILLUSTRATIONS ONLY THAN OR EQUAL TO BREAK OR HEEL JOINT (SEE SKETCH ABOVE). Ryan Bays, P.E. # 91231 4451 St Lucie Blvd, Suite 201 Fort Pierce, FL 34946 FEBRUARY 17, 2017 SCAB APPLIED OVERHANGS STDTL16 +� I A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772409-1010 TRUSS CRITERIA: LOADING: 40-10-0-10 DURATION FACTOR: 115 SPACING: 24' O.C. TOP CHORD: 2X4 OR 2X6 PITCH: 4/12 - 12/12 HEEL HEIGHT: STANDARD HEEL UP TO 12' ENERGY HEEL END BEARING CONDITION NOTES: 1. ATTACH 2X-SCAB (MINIMUM #2 GRADE SPF, HF, SP, DF) TO ONE FACE OF TRUSS WITH TWO ROWS OF 10d COMMON WIRE NAILS (.148' OIA. X 3') SPACED 6' D.C. 2. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE WOOD. 3. WHEN NAILING THE SCABS, THE USE OF A BACKUP WEIGHT IS RECOMMENDED TD AVOID LOOSENING OF THE CONNECTOR PLATES AT THE JOINTS OR SPLICES. 2X SC NOTE: TRUSS BUILT WITHOUT AN OVERHANG. THIS DETAIL IS NOT TO BE USED WHEN OVERHANG HAS BEEN BROKEN OFF. IMPORTANT THIS DETAIL TO BE USED ONLY WITH TRUSSES (SPANS LESS THAN 40') SPACED 24' O.C. MAXIMUM AND HAVING.PITCHES BETWEEN 4'/12 AND 12/12 AND TOTAL TOP CHORD LOADS NOT EXCEEDING 50 PSF. TRUSSES NOT FITTING THESE CRITERIA SHOULD BE EXAMINED INDIVIDUALLY. REFER TO INDIVIDUAL TRUSS DESIGN FOR PLATE SIZES AND LUMBER GRADES Ryan Bays, P.E. 1191231 4451 St. Lucie Blvd, Suite 201 Fort Pierce, FL 34946