Loading...
HomeMy WebLinkAboutEnergy Efficiency CodeR Fr=T%/=M FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 4852 Watersong Way Builder Name: Coastal Construction & Design Street: 4852 Watersong Way Permit Office: City, State, Zip: Fort Pierce , FL , 34949 Permit Number: Owner: Private Residence Jurisdiction: St Lucie Design Location: FL, ST LUCIE_CO_INTL County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall Type45757.9 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=20.0 4672.10 ft2 b. Interior Frame - Wood, Interior R=11.0 1085.80 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 4 d. NIA R= ft2 11. Ceiling Types (1814.0 sqft.) Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=22.0 1814.00 ft2 6. Conditioned floor area above grade (W) 4313 b. NIA R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 7. Windows(856.5 sqft.) Description Area 12. Ducts a. Sup: Attic, Ret: Attic, AH: A/C 1 R ft2 6 1020 a. U-Factor: Dbl, U=0.78 332.69 ft2 b. Sup: Attic, Ret: Attic, AH: A/C 6 701 SHGC: SHGC=0.28 b. U-Factor: Dbl, U=1.06 240.00 ft2 13. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.30 a. Central Unit 57.0 SEER:16.00 c. U-Factor: Dbl, U=0.67 186.67 f:2 b. Central Unit 34.2 SEER:16.00 SHGC: SHGC=0.21 Area Weighted Average Overhang Depth: 5.179 ft. 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.267 a. Electric Strip Heat 4.5 COP:1.00 b. Electric Strip Heat 2 4.0 COP:1.00 8. Skylights Area c. U-Factor:(AVG) N/A ft2 15. Hot water systems SHGC(AVG): N/A a. Electric Cap: 50 gallons 9. Floor Types (4194.9 sqft.) Insulation Area EF: 0.960 a. Floor Over Other Space R=0.0 2477.30 ft2 b. Conservation features b. Slab -On -Grade Edge Insulation R=0.0 928.40 ft2 None c. other (see details) R= 789.20 ft2 16. Credits Pstat Glass/Floor Area: 0.199 Total Proposed Modified Loads: 124.45 PASS Total Baseline Loads: 139.72 1 hereby certify that the plans and specifications covered by Review of the plans and ii%E Srg2, this calculation are in compliance with the Florida Energy specifications covered by this �y0 _ 0W Code. calculation indicates compliance vj iiq''* '__ ��.�� with the Florida Energy Code. ,, •;:r , ,.• , �, O PREPARED BY: 6d(.ri Before construction is completed DATE: 03/ 3/2021 this building will be inspected for compliance with Section 553.908 O �►����' a I hereby certify that this buildi de igned, is in compliance the Florida Energy C Florida Statutes. COD with WEIt OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). 3/23/2021 11:29 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 10