HomeMy WebLinkAboutAPPROVED, A2P0226A - Tower evaluation (03-08-21) [NSB](1)APX Engineering Group, LLC www.apxengineering.com 14471 Miramar Parkway, Suite 202 Florida COA #31948 Miramar, FL 33027 (954) 744-1538 March 8, 2021 Denise Rodriguez T-Mobile USA, Inc. 1300 Concord Terrace, Suite 200 Sunrise, FL 33323 Subject: Structural Evaluation – Monopole Tower (NSB) T-Mobile Site:A2P0226A (PI Fort Pierce) Site Address:Digiorgio Road, Fort Pierce, FL 34950 (27.404492° N, 80.339331° W) APX Project:20-0244.13 Dear Ms. Rodriguez: APX Engineering Group, LLC (APX) has completed an evaluation of the effect on loading upon the subject monopole tower created by installing certain new antenna equipment on the structure. This evaluation was based on information gathered by our representatives in the field, published catalog information, the original tower and foundation design by Sabre Communications Corporation dated April 9, 2020, and information provided by T-Mobile. This evaluation assumes that the existing structural system components are in adequate condition to support their full design capacity. The intent of this report is to assess the effects of the proposed installation on the supporting structure. Our evaluation was based on the following proposed designations, sizes, and configurations of antenna equipment as indicated by T-Mobile. The proposed antenna equipment will be attached to the tower using a commercially available mounting system rated for such applications. As indicated in the tables attached, the proposed antenna equipment loading does not impose a load increase on the existing tower structure when compared to the original design loading. Therefore, in accordance with the Florida Building Code – Existing, 7th Edition (2020), Sections 807.4 and 807.5, the existing tower will support the proposed T-Mobile loading. Should you have any questions or wish to discuss any aspect of this letter, please do not hesitate to contact the undersigned. Sincerely, APX Engineering Group, LLC Giovanni Hall, E.I. Michael A. Phillips, P.E. Staff Engineer Chief Engineer Florida Registration #1100023242 Florida License #68312 Page 1 of 1 Total =Total = Conclusion NOTE: A FULL ANALYSIS OF THE EXISTNG MOUNTING SYSTEM MAY CONCLUDE MORE FAVORABLE RESULTS Proposed Dead Load on Tower:lbs Pass at = 53.44% Proposed Projected Surface Area on Tower:Sq. Ft Pass at = 42.18% -150 A 60° B 180° C 300° Nokia AEHC Panel 0 CommScope FFVV-65C-R3-V1 Panel -0 0 0 0 0 0 NOT USED -0 0 0 0 0 0 00NOT USED - 0 NOT USED - 0 00NOT USED -0 0 0 0 0 NOT USED -0 117.2 0 278 7200 117 3848 3848 0 NOT USED -0 0 00000 0 0 0-0 0 0 0 0 NOT USED 0 NOT USED - 0 0000NOT USED -0 0 0 0 0 -0 0 00NOT USED 1 SitePro1 F3P-HRK12 19991SitePro1 F3P-12W Platform 38.1 38.1 1999 Handrail 9.02 9.02 436 436 0 0 0 NOT USED -0 0 0 0 0 NOT USED -0 0 NOT USED -0 0 0 0 0 0 0 0 0 0 NOT USED -0 0 0 0 0 NOT USED -0 0 0 0 NOT USED - 0 NOT USED -0 0 0 0 0 0 NOT USED -0 0 0 0 0 0 0 NOT USED -0 00NOT USED -0 0 0 0 0 0 0 0 NOT USED -0 0 0 0 0 NOT USED 0 NOT USED -0 0 0 -0 0 0 0 0 0 0 -0 0 0 0 0000Not used -0 0 NOT USED 0 0 0 0 327 0 Nokia HCS 2.0 OVP 00Nokia HCS 2.0 OVP 1.56 0 23.5 0 Nokia AHFIG Radio 2.57 0 70.6 0 6.41 109Radio2.14 0 NOT USED NOT USED -0 0 -0 0 3 Ericsson RRU 4480 B71 3 Ericsson RRU 4460 B25 0 2.38 0 83.8 0 5.7 0 4.72 14.1 0 279 145 114 1141 -0 0 0 7.13 93Radio2.38 155 155 00NOT USED 4.72 0 0 0 Panel 14.1 14.101550 114 1141Ericsson Air 6449 B41 Panel 4.72109 - 0 Nokia AEHC Panel 5.7 0 Ericsson Air 6449 B41 Panel 4.72 14.10CommScope FFVV-65C-R3-V1 Panel 0 NOT USED 0 109 00NOT USED -0 0 0 1 CommScope FFVV-65C-R3-V1 0 155 0 1 CommScope FFVV-65C-R3-V1 0 NOT USED -0 0 0 Panel 14.1 14.1 155 155 145 14.1 155 155 0 Nokia AEHC Panel 5.7 0 109 0 1 CommScope FFVV-65C-R3-V1 Panel 14.1 1 Ericsson Air 6449 B41 Panel 4.72 4.72 114 114145 0 NOT USED Structural Evaluation Existing Tower Structure T-Mobile A2P0226A (PI Fort Pierce), 20-0244.13 G. Hall, March 2021 APX Engineering Group, LLC 14471 Miramar Pkwy, #202, Miramar, FL 33027 Design Loading Proposed Loading Total 1 Design Antenna Loading Panel 278 278 7200 7200 Type Aa (ft2)Wt. (lbs) Each Total Each Total Each Total Each (Per: Original Tower & Foundation Design dated April 9, 2020) Qty.AppurtenanceSec.EL (ft.)Qty.Appurtenance Type Aa (ft2)Wt. (lbs)Sec.EL (ft.)Peripheral Equipment145 Mount145 Nokia AHLOA 0 NOT USED -0 0 Radio 1.56 0 23.5 0 NOT USED -0 0 0 0 DESCRIPTIONDRAWING USAGE CHECKED BYENG. APPROVALDRAWN BYDWG. NO.CPD NO.CEK1 OF 4 BMC 8/30/20178/8/2017F3P-12W12' FORTRESS™TRI-PLATFORM MOUNTWITH WALKWAYSCUSTOMERF3P-12WCLASS SUBPART NO.81 02 PAGE TOLERANCES ON DIMENSIONS, UNLESS OTHERWISE NOTED ARE:SAWED, SHEARED AND GAS CUT EDGES (± 0.030")DRILLED AND GAS CUT HOLES (± 0.030") - NO CONING OF HOLESLASER CUT EDGES AND HOLES (± 0.010") - NO CONING OF HOLESBENDS ARE ± 1/2 DEGREEALL OTHER MACHINING (± 0.030")ALL OTHER ASSEMBLY (± 0.060")TOLERANCE NOTESPROPRIETARY NOTE:THE DATA AND TECHNIQUES CONTAINED IN THIS DRAWING ARE PROPRIETARY INFORMATION OF VALMONTINDUSTRIES AND CONSIDERED A TRADE SECRET. ANY USE OR DISCLOSURE WITHOUT THE CONSENT OFVALMONT INDUSTRIES IS STRICTLY PROHIBITED.Engineering Support Team: 1-888-753-7446valmontLocations:New York, NYAtlanta, GALos Angeles, CAPlymouth, INSalem, ORDallas, TXPARTS LISTNET WT.UNIT WT.LENGTHPART DESCRIPTIONPART NO.QTYITEM596.26198.75 LOW PROFILE PLATFORM CORNER WELDMENTX-LPP-CW31357.63119.21 SIDE ARM WELDMENT FOR 12' LOW PROFILE PLATFORMSX-LPP-SA1232253.2584.42 WELDMENT FOR 3-SIDED HEAVY DUTY RING MOUNTX-RM3HD33259.4486.48 WALKWAY FOR 12' LOW PROFILE PLATFORMX-LPP-W123484.117.01 FACE PIPE CONNECTION BRACKET FORTRESS PLATFORMX-LPP-PC12579.376.61 FORTRESS CROSSOVER PLATEX-SCX3-FR12615.251.272 1/2 inCORNER WELDMENT ATTACHMENT ANGLEX-LPP-A712716.662.78 HINGE FOR LOW PROFILE PLATFORM WALKWAYX-LPP-H68230.8176.94150 in2-7/8'' X 150" (2-1/2" SCH. 40) GALVANIZED PIPEP30150394.790.4048 in5/8" x 48" THREADED ROD (HDG.)G58R-4812104.790.4024 in5/8" x 24" THREADED ROD (HDG.)G58R-2412104.180.70 5/8" x 8" THREADED ROD (HDG.)G58R-861155.171.15 5/8" X 3" X 5-1/4" X 2-1/2" U-BOLT (HDG.)X-UB5300481224.001.00 5/8" X 2-5/8" X 4-1/2" X 2" U-BOLT (HDG.)X-UB5258241311.700.98 5/8" X 3" X 4-1/4" X 2-1/2" U-BOLT (HDG.)X-UB5304121413.990.29 5/8" x 2-1/4" HDG HEX BOLT GR5 G58214481513.110.071/8 in5/8" HDG USS FLATWASHERG58FW186165.320.03 5/8" HDG LOCKWASHERG58LW2041726.500.13 5/8'' HDG HEAVY 2H HEX NUTG58NUT20418TOTAL WT. # 2122.032-3/8" TO 2-7/8"ANTENNA MOUNTING PIPES(0RDERED SEPARATELY) DESCRIPTIONDRAWING USAGE CHECKED BYENG. APPROVALDRAWN BYDWG. NO.CPD NO.CEK2 OF 4 BMC 8/30/20178/8/2017F3P-12W12' FORTRESS™TRI-PLATFORM MOUNTWITH WALKWAYSCUSTOMERF3P-12WCLASS SUBPART NO.81 02 PAGE TOLERANCES ON DIMENSIONS, UNLESS OTHERWISE NOTED ARE:SAWED, SHEARED AND GAS CUT EDGES (± 0.030")DRILLED AND GAS CUT HOLES (± 0.030") - NO CONING OF HOLESLASER CUT EDGES AND HOLES (± 0.010") - NO CONING OF HOLESBENDS ARE ± 1/2 DEGREEALL OTHER MACHINING (± 0.030")ALL OTHER ASSEMBLY (± 0.060")TOLERANCE NOTESPROPRIETARY NOTE:THE DATA AND TECHNIQUES CONTAINED IN THIS DRAWING ARE PROPRIETARY INFORMATION OF VALMONTINDUSTRIES AND CONSIDERED A TRADE SECRET. ANY USE OR DISCLOSURE WITHOUT THE CONSENT OFVALMONT INDUSTRIES IS STRICTLY PROHIBITED.Engineering Support Team: 1-888-753-7446valmontLocations:New York, NYAtlanta, GALos Angeles, CAPlymouth, INSalem, ORDallas, TXCLTO GAIN ACCESSALL WALKWAYS OPENWITH REMOVAL OFTWO INSIDE BOLTS12" - 60"MONOPOLE150 9/32"28 29/32"73 7/16"28 29/32"150"173 17/32"20 5/8"0° - 110°47 1/4"47 1/4"47 1/4"70 15/16" DETAIL ADETAIL BDETAIL CDESCRIPTIONDRAWING USAGE CHECKED BYENG. APPROVALDRAWN BYDWG. NO.CPD NO.CEK3 OF 4 BMC 8/30/20178/8/2017F3P-12W12' FORTRESS™TRI-PLATFORM MOUNTWITH WALKWAYSCUSTOMERF3P-12WCLASS SUBPART NO.81 02 PAGE TOLERANCES ON DIMENSIONS, UNLESS OTHERWISE NOTED ARE:SAWED, SHEARED AND GAS CUT EDGES (± 0.030")DRILLED AND GAS CUT HOLES (± 0.030") - NO CONING OF HOLESLASER CUT EDGES AND HOLES (± 0.010") - NO CONING OF HOLESBENDS ARE ± 1/2 DEGREEALL OTHER MACHINING (± 0.030")ALL OTHER ASSEMBLY (± 0.060")TOLERANCE NOTESPROPRIETARY NOTE:THE DATA AND TECHNIQUES CONTAINED IN THIS DRAWING ARE PROPRIETARY INFORMATION OF VALMONTINDUSTRIES AND CONSIDERED A TRADE SECRET. ANY USE OR DISCLOSURE WITHOUT THE CONSENT OFVALMONT INDUSTRIES IS STRICTLY PROHIBITED.Engineering Support Team: 1-888-753-7446valmontLocations:New York, NYAtlanta, GALos Angeles, CAPlymouth, INSalem, ORDallas, TXAX2 X2 X2X2 X2 X2X2 X2 X2BX2COR 13961216171814161718151617181216171851516171814815161718 DETAIL EDETAIL DDETAIL FDESCRIPTIONDRAWING USAGE CHECKED BYENG. APPROVALDRAWN BYDWG. NO.CPD NO.CEK4 OF 4 BMC 8/30/20178/8/2017F3P-12W12' FORTRESS™TRI-PLATFORM MOUNTWITH WALKWAYSCUSTOMERF3P-12WCLASS SUBPART NO.81 02 PAGE TOLERANCES ON DIMENSIONS, UNLESS OTHERWISE NOTED ARE:SAWED, SHEARED AND GAS CUT EDGES (± 0.030")DRILLED AND GAS CUT HOLES (± 0.030") - NO CONING OF HOLESLASER CUT EDGES AND HOLES (± 0.010") - NO CONING OF HOLESBENDS ARE ± 1/2 DEGREEALL OTHER MACHINING (± 0.030")ALL OTHER ASSEMBLY (± 0.060")TOLERANCE NOTESPROPRIETARY NOTE:THE DATA AND TECHNIQUES CONTAINED IN THIS DRAWING ARE PROPRIETARY INFORMATION OF VALMONTINDUSTRIES AND CONSIDERED A TRADE SECRET. ANY USE OR DISCLOSURE WITHOUT THE CONSENT OFVALMONT INDUSTRIES IS STRICTLY PROHIBITED.Engineering Support Team: 1-888-753-7446valmontLocations:New York, NYAtlanta, GALos Angeles, CAPlymouth, INSalem, ORDallas, TXEX2 X2DX2X2 X2 X2X2 X2 X2FX2 X2 X2X2 X2 X2OR 13319215161817310171815161718711161718711161718BOTH ANGLE CLAMPSMUST ENGANGE THE RAILON THE TRUSS ARM.(BOTH SIDES)61216171812161718 DETAIL ADETAIL BDESCRIPTIONDRAWING USAGE CHECKED BYENG. APPROVALDRAWN BYDWG. NO.CPD NO.CEK1 OF 2 BMC 9/14/20178/29/2017F3P-HRK12HANDRAIL KIT FOR12' FORTRESS™ PLATFORMCUSTOMERF3P-HRK12CLASS SUBPART NO.81 02 PAGE TOLERANCES ON DIMENSIONS, UNLESS OTHERWISE NOTED ARE:SAWED, SHEARED AND GAS CUT EDGES (± 0.030")DRILLED AND GAS CUT HOLES (± 0.030") - NO CONING OF HOLESLASER CUT EDGES AND HOLES (± 0.010") - NO CONING OF HOLESBENDS ARE ± 1/2 DEGREEALL OTHER MACHINING (± 0.030")ALL OTHER ASSEMBLY (± 0.060")TOLERANCE NOTESPROPRIETARY NOTE:THE DATA AND TECHNIQUES CONTAINED IN THIS DRAWING ARE PROPRIETARY INFORMATION OF VALMONTINDUSTRIES AND CONSIDERED A TRADE SECRET. ANY USE OR DISCLOSURE WITHOUT THE CONSENT OFVALMONT INDUSTRIES IS STRICTLY PROHIBITED.Engineering Support Team: 1-888-753-7446valmontLocations:New York, NYAtlanta, GALos Angeles, CAPlymouth, INSalem, ORDallas, TXPARTS LISTNET WT.UNIT WT.LENGTHPART DESCRIPTIONPART NO.QTYITEM83.1527.72 CORNER WELDMENT FOR 3-SIDED FORTRESS PLATFORM HADNRAIL KITSX-F3PHRW3179.376.61 FORTRESS CROSSOVER PLATEX-SCX3-FR122137.3145.77150 in2-3/8" O.D. X 150" SCH 40 GALVANIZED PIPEP21503327.591.15 5/8" X 3" X 5-1/4" X 2-1/2" U-BOLT (HDG.)X-UB530024454.011.00 5/8" X 2-5/8" X 4-1/2" X 2" U-BOLT (HDG.)X-UB52585457.610.071/8 in5/8" HDG USS FLATWASHERG58FW10862.820.03 5/8" HDG LOCKWASHERG58LW108714.030.13 5/8'' HDG HEAVY 2H HEX NUTG58NUT1088AX2 X2 X2OR5X2 X2 X2BX2 X2 X2TOTAL WT. # 405.871256784678567832-3/8" TO 2-7/8"ANTENNA MOUNTING PIPES(ORDERED SEPARATELY) DESCRIPTIONDRAWING USAGE CHECKED BYENG. APPROVALDRAWN BYDWG. NO.CPD NO.CEK2 OF 2 BMC 9/14/20178/29/2017F3P-HRK12HANDRAIL KIT FOR12' FORTRESS™ PLATFORMCUSTOMERF3P-HRK12CLASS SUBPART NO.81 02 PAGE TOLERANCES ON DIMENSIONS, UNLESS OTHERWISE NOTED ARE:SAWED, SHEARED AND GAS CUT EDGES (± 0.030")DRILLED AND GAS CUT HOLES (± 0.030") - NO CONING OF HOLESLASER CUT EDGES AND HOLES (± 0.010") - NO CONING OF HOLESBENDS ARE ± 1/2 DEGREEALL OTHER MACHINING (± 0.030")ALL OTHER ASSEMBLY (± 0.060")TOLERANCE NOTESPROPRIETARY NOTE:THE DATA AND TECHNIQUES CONTAINED IN THIS DRAWING ARE PROPRIETARY INFORMATION OF VALMONTINDUSTRIES AND CONSIDERED A TRADE SECRET. ANY USE OR DISCLOSURE WITHOUT THE CONSENT OFVALMONT INDUSTRIES IS STRICTLY PROHIBITED.Engineering Support Team: 1-888-753-7446valmontLocations:New York, NYAtlanta, GALos Angeles, CAPlymouth, INSalem, ORDallas, TX42"TYP.150 11/32"150"173 19/32"