Loading...
HomeMy WebLinkAbout2200139-1d Compaction signedHeadquarters 11345 U.S. Highway 1 Sebastian, FL. 32958 Orlando 723 Progress Way Sanford, FL. 32771 Mailing PO Box 78-1377 Sebastian, FL. 32978 Phone: 772-589-0712 C.A.# 5693 KSMengineering.net January 6, 2022 KSM JOB # :2200139-1d/BS/jam CONTRACTOR:South Florida Land Clearing, Inc. 15701 Orange Avenue Fort Pierce, Florida 34945 JOB LOCATION:20017 Southern Star Drive Lot 6 Fort Pierce, Florida PERMIT #: Respectfully, PE # 68366 01/06/22 Proudly Serving Florida since 1990 Test report shall not be reproduced, except in full, without the written approval of KSM Engineering & Testing Email: sflcgw@gmail.com Certified Women Owned Business - WBE To Whom it may concern, As requested, we tested the compacted fill for the House Pad. To determine if the fill was properly compacted on the pad to a depth of 4 feet, we performed nuclear density tests on the top two feet. To estimate the soil density below a depth of 2 feet we used a Static Cone Penetrometer. During the tests, a shaft with a conical point is pushed through soil and the soil resistance measured on a calibrated gauge. After the soil resistance is measured, the hole is advanced with a hand-auger in 1-foot increments to permit a continuation of measurement of density versus depth. Test Results: Nuclear density tests performed on the top 2 feet indicates the compaction exceeds the project specifications of 95% (ASTM 1557). Static Cone Penetrometer readings indicate the compacted backfill below 2 feet are generally well compacted to a depth of 4 feet. Based on the nuclear density tests and Static Cone Penetrometer readings, it appears the fill on the house pad was properly compacted. Should you have any questions, please feel free to contact our office. Julie E. Keller, P.E. President Geotechnical Engineering - Construction Materials Testing - Special Inspections - Civil and Structural Consulting Headquarters 11345 U.S. Highway 1 Sebastian, FL. 32958 Orlando 723 Progress Way Sanford, FL. 32771 Mailing PO Box 78-1377 Sebastian, FL. 32978 Phone: 772-589-0712 C.A.# 5693 KSMengineering.net KSM JOB #:2200139-1d/BS/jam NUC #456 Nuc Model:MC-1 Elite Nuc Serial #:31456 20017 Southern Star Drive Lot 6 Fort Pierce, Florida House Pad DEPTH PEN READ DRY DENSITY MAX. DRY PROCTOR VALUE (P.C.F) PERCENT COMPACTION 1 N.E.0" - 12"45 111.6 113.3 98.5% 2 Center ""112.1 "98.9% 3 S.W.""112.5 "99.3% 4 S.E.12" - 24""112.3 "99.1% 5 N.W.""111.8 "98.7% Proctor Optimum Moisture: Proctor Max. Dry Density: P.C.F. @ Test Locations the Density & Penetrometer readings indicate the Degree of Compaction Meets Minimum Requirement 1/6/2022 Email: sflcgw@gmail.com 10.0% Julie E. Keller, P.E. President SOIL COMPACTION REPORT ASTM D 1557 and ASTM D 6938 DATE TESTED:January 5, 2022 In Place Moisture: PERMIT #: JOB LOCATION: Brown Sand with Traces of Shell and Rock CONTRACTOR:South Florida Land Clearing, Inc. Proudly Serving Florida since 1990 Certified Women Owned Business - WBE 8.5% PE # 68366 for Unstaked Foundation 113.3 Disclaimer:Contractor is responsible to maintain the tested area in the condition that KSM completed the indicated passed compaction test.KSM is not responsible if the tested area has been altered from the approved inspected condition. Test report shall not be reproduced, except in full, without the written approval of KSM Engineering & Testing Geotechnical Engineering - Construction Materials Testing - Special Inspections - Civil and Structural Consulting ITEM TESTED: Soil Description: TEST LOCATION OF SAMPLE Headquarters 11345 U.S. Highway 1 Sebastian, FL. 32958 Orlando 723 Progress Way Sanford, FL. 32771 Mailing PO Box 78-1377 Sebastian, FL. 32978 Phone: 772-589-0712 C.A.# 5693 KSMengineering.net DATE TESTED:KSM JOB # :2200139-1d/BS/jam PERMIT #: CONTRACTOR:South Florida Land Clearing, Inc. JOB LOCATION:20017 Southern Star Drive Lot 6 Fort Pierce, Florida Soil Description: Brown Sand with Traces of Shell and Rock Proctor Optimum Moisture: 10.0% Proctor Max. Dry Density: P.C.F. 113.3 Julie E. Keller, P.E. President PE # 68366 1/6/2022 SOIL COMPACTION REPORT ASTM D 1557 Test report shall not be reproduced, except in full, without the written approval of KSM Engineering & Testing Certified Women Owned Business - WBE Proudly Serving Florida since 1990 Geotechnical Engineering - Construction Materials Testing - Special Inspections - Civil and Structural Consulting January 5, 2022 108.0 109.0 110.0 111.0 112.0 113.0 114.0 115.0 5 6 7 8 9 10 11 12 13 W E I G H T P . C . F . D R Y Moisture -% of Dry Weight