HomeMy WebLinkAboutENERGY LOT 19 FORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: KHOV-LELIA Builder Name: KHOVNANAIN HOMES
Street: 5150 ARM INA PLACE Permit Office:
City,State,Zip: FORT PIERCE, FL, Permit Number:
Owner: LELIA MODEL LOT 19 @ WATERSTONE Jurisdiction:
Design Location: FL, Fort Pierce County: St. Lucie(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 10. Wail Type*1844.9 sqft.) Insulation Area
2. Single family or multiple family Detached a. Concrete Block-Int Insul, Exterior R=4.1 1508.90 ft2
b. Frame-Wood,Adjacent R=11.0 336.00 ft2
3. Number of units,if multiple family 1 c. NIA R= ft2
4. Number of Bedrooms 4 d. NIA R= ft2
11. Ceiling Types (1917.0 sqft.) Insulation Area
5. Is this a worst case? No a. Under Attic(Vented) R=30.0 1917.00 ft2
6. Conditioned floor area above grade (ft2) 1917 b. NIA R= ft2
Conditioned floor area below grade(ft2) 0 c. NIA R= ft2
7. Windows(201.8 sqft.) Description Area 12. Ducts R ft2
a. U-Factor: Dbl, U=0.28 159.83 ft2 a. Sup:Attic, Ret: LAUNDRY,AH:LAUNDRY 6 250
SHGC: SHGC=0.30
b. 1-1-Factor: Dbl, U=0.55 42.00 ft2 13. Cooling systems kBtulhr Efficiency
SHGC: SHGC=0.34 a. Central Unit 35.2 SEER:16.00
c. U-Factor: NIA ft2
SHGC:
Area Weighted Average Overhang Depth: 1.570 ft. 14. Heating systems kBtulhr Efficiency
Area Weighted Average SHGC: 0.308 a. Electric Strip Heat 32.0 COP:1.00
8. Skylights Area
c. U-Factor:(AVG) NIA ft2 15. Hot water systems
SHGC(AVG): NIA a. Electric Cap:50 gallons
9. Floor Types (1917.1 sqft.) Insulation Area EF:0.950
a.Slab-On-Grade Edge Insulation R=0.0 1917.10 ft2 b. Conservation features
b. NIA R= ft2 None
c. N/A R= ft2 16. Credits Pstat
Glass/Floor Area: 0.105
Total Proposed Modified Loads: 59.66 PASS
Total Baseline Loads: 61.14
1 hereby certify that the plans and specifications covered by Review of the plans and 111E 3�
this calculation are in compliance w' the Florida Energy specifications covered by this
Code. calculation indicates compliance
with the Florida Energy Code.
PREPARED BY: Before construction is completed
DATE: P this building will be inspected for
- 4;
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance Florida Statutes.
-
with the Florida Energy Code. 'CO'D W�vr
OWNER/AGENT: BUILDING OFFICIAL:
DATE: DATE:
- Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
6/15/2021 1:56 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 1 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: KHOV-LELIA Bedrooms: 4 Address Type: Street Address
Building Type: User Conditioned Area: 1917 Lot#
Owner Name: LELIA MODEL LOT 19 @ WA Total Stories: 1 Block/Subdivisiom
#of Units: 1 Worst Case: No PlatBook:
Builder Name. KHOVNANAIN HOMES Rotate Angle: 0 Street: 5150 ARMINA PLACE
Permit Office: Cross Ventilation: No County: St. Lucie
Jurisdiction: Whole House Fan: No City, State,Zip: FORT PIERCE ,
Family Type: Detached FL
New/Existing: New(From Plans)
Comment:
CLIMATE
/ Design Temp Int Design Temp Heating Design Daily Temp
v Design Location TMY Site 97.5% 2.5% Winter Summer Degree Clays Moisture Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low
BLOCKS
Number Name Area Volume
1 Entire House 1917 16614.7
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated
1 EXT STE LIV PLUS 199 1765.1 No 0 4 1 No Yes Yes
2 WIC STE PLS BED 25 220 No 0 1 No Yes Yes
3 FX STE PLUS BED 132 1161.6 No 0 1 No Yes Yes
4 EX STE BATH 54 475.2 No 0 1 No Yes Yes
5 FOYER 81 712.8 No 0 1 No Yes Yes
6 HALL BATH 54 475.2 No 0 1 No Yes Yes
7 LAUNDRY 77 677.6 No 0 1 No Yes Yes
8 BED 3 126 1108.8 No 1 1 No Yes Yes
9 BED 2 126 1109 No 1 1 No Yes Yes
'Q KIT GREAT RM DI 672 5644.5 No 0 1 No Yes Yes
11 M BATH 95 836 No 0 1 No Yes Yes
12 MASTER SUITE 210 1848 No 2 1 No Yes Yes
13 MASTER WIC 66 580.8 No 0 1 No Yes Yes
FLOORS
# Floor Type space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
1 Slab-On-Grade Edge Insulatio EXT STE LIV PL 46 ft 0 199.3 ft2 ---- 0 1 0
2 Slab-On-Grade Edge Insulatio WIC STE PLS BE 4.5 ft 0 25 ft2 __-- 0 1 0
3 Slab-On-Grade Edge Insu€atio EX STE PLUS B 8.5 ft 0 132 ft2 ---- 0 1 0
4 Slab-On-Grade Edge Insulatio EX STE BATH 1 ft 0 54 ft2 ___- 1 0 0
6/15/2021 1:56 PM EnergyGaugeO USA 7.C.00-FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
5 Slab-On-Grade Edge Insulatio FOYER 19 ft 0 81.3 ft2 ---- 1 0 0
6 Slab-On-Grade Edge Insuiatio HALL BATH 1 ft 0 54 ft2 ---_ 1 0 0
7 Slab-On-Grade Edge Insuiatio LAUNDRY 7.5 ft 0 77 ft2 ---- 1 0 0
8 Slab-On-Grade Edge Insulatio BED 3 22.5 ft 0 126 ft2 -- 0 1 0
9 Slab-On-Grade Edge Insulatio BED 2 12.5 ft 0 126 ft2 -_-- 0 1 0
10SIab-On-Grade Edge Insulatio KIT GREAT RM 43.5 ft 0 672 ft2 ---- 1 0 0
11Slab-On-Grade Edge Insulatio M BATH 9 ft 0 94.5 ft2 ---_ 1 0 0
12SIab-On-Grade Edge Insulatio MASTER SUITE 28 ft 0 210 ft2 ---- 0 1 0
13SIab-On-Grade Edge Insulatio MASTER WIC 6 ft 0 66 ft2 ---- 0 1 0
ROOF
/ Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch
1/ # Type Materials Area Area Color Barr Abscr. Tested Tested Insul. (deg)
1 Hip Composition shingles 2076 ft2 0 ft2 Medium N 0.9 No 0.9 No 0 22.6
ATTIC
v # Type Ventilation Vent Ratio(1 in) Area RBS IRCC
1 Full attic Vented 150 1917 ft2 N N
CEILING
# Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type
1 Under Attic(Vented) EXT STE LIV PL 30 Blown 199 ft2 0.1 Wood
2 Under Attic(Vented) WIC STE PLS BE 30 Blown 25 ftz 0.1 Wood
3 Under Attic(Vented) EX STE PLUS B 30 Blown 132 ft2 0.1 Wood
4 Under Attic(Vented) EX STE BATH 30 Blown 54 ft2 0.1 Wood
5 Under Attic(Vented) FOYER 30 Blown 81ft2 0.1 Wood
6 Under Attic(Vented) HALL BATH 30 Blown 54 ft2 0.1 Wood
7 Under Attic(Vented) LAUNDRY 30 Blown 77 ft2 0.1 Wood
8 Under Attic(Vented) BEd 3 30 Blown 126 ft2 0.1 Wood
9 Under Attic(Vented) BED 2 30 Blown 126 ft2 0.1 Wood
10 Under Attic(Vented) KIT GREAT RM 30 Blown 672 ft2 0.1 Wood
11 Under Attic(Vented) M BATH 30 Blown 95 ft2 0.1 Wood
12 Under Attic(Vented) MASTER SUITE 30 Blown 210 ft2 0.1 Wood
13 Under Attic(Vented) MASTER WIC 30 Blown 66 ft2 0.1 Wood
6/15/2021 1:56 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 3 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent Space Cavity Width Height Sheathing Framing Solar Below
0
1 SE Exterior Concrete Block-Int InsEDCT STE LIV 4.1 11 7 9 4 108.1 ft2 0 0 0.5 0
2 SW Exterior Concrete Block-Int InsEXT STE L[V 4.1 15 4 10 0 153.3 ft2 0 0 0.5 0
3 SW Exterior Concrete Block-Int InsOX STE PLU 4.1 7 8 10 0 76.7 ft2 0 0 0.5 0
4 SE Exterior Concrete Block-Int Insul FOYER 4.1 6 4 9 4 59.1 ft2 0 0 0.5 0
5 SW Exterior Concrete Block-Int Insul FOYER 4.1 11 4 10 0 113.3 ft2 0 0 0.5 0
6 NE Exterior Concrete Block-Int Insul BED 3 4.1 11 7 9 4 108.1 ft2 0 0 0.5 0
7 NE Exterior Concrete Block-Int Insul BED 2 4.1 11 7 9 4 108.1 ft2 0 0 0.5 0
8 SW Exterior Concrete Block-Int InsLKIT GREAT 4.1 25 2 10 0 251.7 ft2 0 0 0.5 0
9 NW Exterior Concrete Block-Int InsXIT GREAT 4.1 15 1 9 4 140.8 ft2 0 0 0.5 0
10 NE Exterior Concrete Block-Int Insul M BATH 4.1 8 9 9 4 81.7 ft' 0 0 0.5 0
11 NE Exterior Concrete Block-Int InsMASTER SUI 4.1 14 1 9 4 131.4 ft2 0 0 0.5 0
12 NW Exterior Concrete Block-Int InsMASTER SUI 4.1 13 1 9 4 122.1 ft2 0 0 0.5 0
13 NW Exterior Concrete Biock-Int InsLUASTER WI 4.1 5 10 9 4 54.4 ft2 0 0 0.5 0
14 NW Garage Frame-Wood KIT GREAT 11 36 0 9 4 336.0 ft2 0 0 0.5 0
DOORS
# Ornt Door Type Space Storms U-Value Width Height Area
Ft In Ft In
1 SW Insulated EXT STE LIV None .39 3 2 6 8 21.1 ft2
2 SW Insulated EXT STE LIV None .39 3 2 6 8 21.1 ft2
3 NW Wood KIT GREAT None .39 3 2 6 8 21.1 ft2
WINDOWS
Orientation shown is the entered, Prolposed orientation.
Wall Overhang
# Ornt [D Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening
1 SE 1 Metal Double(Tinted) Yes 0.28 0.3 N 22.9 ft2 1 ft 0 in 1 ft 0 in None None
2 SW 3 Metal Double(Tinted) Yes 0.28 0.3 N 23.0 ft2 6 ft 0 in 1 ft 0 in None None
3 SW 5 Metal Double(Tinted) Yes 0.28 0.3 N 15.0 ft2 1 ft 0 in 1 ft 0 in None None
4 NE 6 Metal Double(Tinted) Yes 0.28 0.3 N 15.0 ft2 1 ft 0 in 1 ft 0 in None None
5 NE 7 Metal Double(Tinted) Yes 0.28 0.3 N 15.0 ft2 1 ft 0 in 1 ft 0 in None None
6 SW 8 Metal Double(Tinted) Yes 0.28 0.3 N 23.0 ft2 1 ft 0 in 1 ft 0 in None None
7 NW 9 Metal Double(Tinted) Yes 0.28 0.3 N 23.0 ft2 1 ft 0 in 1 ft 0 in None None
8 NW 9 Metal Double(Tinted) Yes 0.55 0.34 N 42.0 ft2 1 ft 0 in 1 ft 0 in None None
9 NW 12 Metal Double(Tinted) Yes 0.28 0.3 N 22.9 ft' 1 ft 0 in 1 ft 0 in None None
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation
1 380 ft2 380 ft2 64 ft 8 ft 1
6/15/2021 1:56 PM EnergyGauge®USA 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 4 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
INFILTRATION
# Scope Method SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000385 1938.4 106.35 199.65 .1304 7
HEATING SYSTEM
# System Type Subtype Speed Efficiency Capacity Block Ducts
1 Electric Strip Heat/ None COP:1 32 kBtulhr 1 sys#1
COOLING SYSTEM
# System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts
1 Central Unit/ Spiit Sing[ SEER: 16 35.2 kBtulhr cfm 0.81 1 sys#1
HOT WATER SYSTEM
# System Type SubType Location EF Cap Use SetPnt Conservation
1 Electric None Garage 0.95 50 gat 60.9 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cert # Company Name System Model# Collector Model# Area Volume FEF
None None ft2
DUCTS
{ ----Supply---- ----Return---- Air CFM 25 CFM25 HVAC#
# Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool
1 Attic 6 250 ft2 LAUNDRY 1 ft2 Default Leakage LAUNDRY (Default) (Default) 1 1
TEMPERATURES
Programable Thermostat: Y Ceiling Fans:
CoolingJan [ ]Feb Mar Apr Ma X Jun X Jul rj
Au �Xj Se Oct Nov Dec
Heatin Jan [X]Feb Mar Mar f Ar f May Jun Jul Aug SepOct 7C�Nov X Dec
Ventin Jan [ ]Feb [X Mar [X A r [ Ma Jun Jul Au Se Oct [X Nov [ Dec
6/15/2021 1:56 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 5 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 78 78 78 78 78 78 78 78 78 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
MASS
Mass Type Area Thickness Furniture Fraction Space
Default(8 Ibs/sq.ft. 0 ft, 0 ft 0.3 BED 2
Default(8 Ibslsq.ft. ft2 ft 0.3 BATH 2
Default(8 Ibs/sq.ft, ft2 ft 0.3 LAUNDRY
Default(8 Ibslsq.ft. ft2 ft 0.3 KITCHEN
Default(8 Ibslsq.ft. ft2 ft 0.3 GREAT ROOM
Default(8 Ibslsq.ft. ft2 ft 0.3 WIC MASTER
Default(8 Ibslsq.ft. ftz ft 0.3 MASTER BATH
Default(8 Ibs/sq.ft. ftZ ft 0.3 TIOLET MASTER
Default(8 Ibsls .ft. ft2 ft 0.3 MASTER SUITE
6tl512021 1:56 PM EnergyGauge®USA 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 6 of 6
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 98
The lower the EnergyPerformance Index, the more efficient the home.
5150 ARMINA PLACE, FORT PIERCE, FL,
1. New construction or existing New(From Plans) 10. Wall Type and Insulation Insulation Area
2. Single family or multiple family Detached a.Concrete Block-int lnsul, Exterior R=4.1 1508.90 ft2
b. Frame-Wood,Adjacent R=11.0 336.00 ft2
3. Number of units, if multiple family 1 c. NIA R= ft2
4. Number of Bedrooms 4 d. NIA R= ft2
5. Is this a worst case? No 11. Ceiling Type and insulation level Insulation Area
a. Under Attic(Vented) R=30.0 1917.00 ft2
6. Conditioned floor area(ft2) 1917 b. NIA R= ft2
7. Windows'"" Description Area
G. NIA R= ft2
a U-Factor: Dbl, U=0.28 159.83 ft2 12. Ducts, location &insulation level R ft2
SHGC: SHGC=0.30 a.Sup:Attic, Rat: LAUNDRY,AH: LAUNDRY 6 250
b. U-Factor: Dbl, U=0.55 42.00 ft2
SHGC: SHGC=0.34 13.Cooling systems kBtulhr Efficiency
c. U-Factor: NIA ft2 a. Central Unit 35.2 SEER:16.00
SHGC:
d. U-Factor: NIA ft2
SHGC: 14. Heating systems kf3tu/hr Efficiency
a. Electric Strip Heat 32.0 COP:1.00
Area Weighted Average Overhang Depth: 1.570 ft.
Area Weighted Average SHGC: 0.308
8. Skylights Description Area 15. Hot water systems
a. Electric Cap: 54 gallons
a. U-Factor(AVG): NIA ft2EF:0.95
SHGC(AVG): NIA
b. Conservation features
9. Floor Types Insulation Area None
a. Slab-On-Grade Edge Insulation R=0.0 1917.10 ft2 Credits(Performance method) Pstat
b. NIA R= ft2
c. NIA R= ft2
1 certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded) - �
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features. .,O;, .;' _;; ,a,
Builder Signature: Date: cr. i a
Address of New Horne: City/FL Zip: ,
O'D
Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
`Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
6/15/2021 1:56 PM EnergyGaugeCR)USA 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 1 of 1