HomeMy WebLinkAboutM-1 LOT 19 PROJECT #: KHOV-LELIA
LOT: 19
SYSTEM
BRAND - CARRIER: 3.0 TON Cu AHU
MODEL : CA16NA037 FX4DNF037
DIMENSIONS - H X WX D 28-5/16 X 35.0 X 35.0 49-5/8" X 21-1/8" X 22-1/16"
MCA 18.2 55.1
MAX FUSE (AMPS) 30 60 GREAT
HEAT STRIP (KW) N/A 10 OWNER'S ROOM
REF. LINE SIZE- ("O.D.) SUCTION 3/4 SUITE OS WIC
REF. LINE SIZE- (" O.D.) LIQUID 3/8 W
8 X4
SEER: 16.0 14
SENSIBLE BTU'S: 28,500 CFM ICI ^^ r,
' 6 700 12"X12" H � W
LATENT BTU S. 12"X12„153 9»� CFM
TOTAL BTU'S: 35,200 CFM 16"X16" J W
RH 14' 16"X16" �I w
RH H
9"o
EXHAUST FAN SCHEDULE »
#1 50 CFM w/4" T-FIN-V.T.O. 8 x 4 W
I 21 0 _
CFM
° 4»� doll
FDININGDUCTWORK - FLEXIBLEOWNER'S _ of AREA
BATH KITCHEN °
R-FACTOR- 6 ------- °
I
NOTE: DUCTWORK TRUNK LINE o °
AND DROP LOCATIONS MAYVARY
FROM PLAN DUE TO TRUSS 00 L-------1-J
CONFIGURATIONS 0 12"X8"
222
I CFM
I I
I I
NOTE: BEDROOM 2 8»0
I --------------------
1. REFRIGERANT LINES w/1/2"T-CELL INSULATION --------- -------
2. USE 3/4"SCH 40 PVC FOR CONDENSATE DRAINS. CONDENSATE DRAIN OUTLETS TO BE MINIMUM 121,OFF
SLAB 3. AUXILLARY FLOAT SWITCHES ON AHU'S 10"�6" 14»0 BAT o 4"0
CFM BAT 8"X4"
50
CFM
0
8 X4" 1 1 8"X4" Q
C 5 0' 0)------ -------, w
CEILING 7"0 )14"X6" �� CFM � � � �
CU RH 4 0
0 0 ° �
2 18„ 4'0 � °' z C _ Eo
(2)14» 14 0 ( ) --- o c3 -,a, o o ov
X6' RH ------ w w z o 0 ,L
SUPPLY 0R � z z o I op
PLENUM o a oN E
4 0 8 4„ 2-20"X6" r °° ^^ 0
5 9110 RH � � � C � � � c°
CONDENSATE DRAIN CF Q a °.�' ' o
AHU TO EXTERIOR $ 0 �` ao E
& REF. LINES 7"0 ir n a- L,_ 3 v
TO AHU 7"O
4" DRYER
OPEN TO V.T.O.
R/A GRILL 10"X6 28 GAUGE
8
CFM GALV. PIPE 10"X6"
75 4»0
—METAL STAND CFM
BEDROOM 3
XT STE PLUS REVISIONS
BEDROOM
N0. DESC. DATE
AHU MOUNTING DETAIL ' 8 2)1 ' C6"
��0 „X4„ 4 DRYER RH
5 8 GAUGE
SCALE: N.T.S. CFM ALV. PIP
-------------------
ID I
1--------1_J
12"X8"
143
(P��aGF GARAGE CFM DRAWN BY: DL/GM/HP
CHECKED BY: CS
DATE: 5-2021
THE DESIGN PLAN & SPECIFI—
� s� CATIONS SUBMITTED HERE WITH
EXT STE PLUS ARE THE SOLE PROPERTY OF
t
GO =.'•.• LINDSTROM AIR CONDITIONING
LIVING ROOM-�..
,: :•'' � INC. & ARE NOT TO BE REPR—
MIN.4°CONCRETE SLAB <: SLAB c�o-o° ODUCED WITHOUT THE WRITTEN
F.F.OF HOUSE
PERMISSION.
TIE DOWN CLIPS WITH THESE DOCUMENTS ARE
L/4°xi-3i4°TAPCONINSLAB SPECIFICALLY SUBMITTED FOR
#12 SCREWS INTO CU CABINET THE EXCLUSIVE USE OF THE
LINDSTROM AIR CONDITIONING
PER TIE DOWN SPEC'S INC. IN THE CONSTRUCTION OF
DESIGNED SYSTEMS.
LINDSTROM A/C DESIGNS
UNDER — F.S. 489 & F.S. 471
CU MOUNTING DETAIL SHEET TITLE:
SCALE: N.T.S. MECHANICAL PLAN
MECHANICAL PLAN
SHEET NO.:
SCALE: 1 /4"= 1 '-O"