Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
MANUAL J LOT 19
Project Summary Date: o•iy Entire House By: LINDSTROM A'"`°"°' Lindstrom Air Conditioning 3581 W MCNAB RD, POMPANO BEACH, FL 33069 Phone:954-421-4117 Fax:954-420-0064 Web:www.lindstromair.com Project • • For: KHOVNANIAN HOMES Notes: LOT 19- LELIA MODEL Design Information Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range M Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 22320 Btuh Structure 21097 Btuh Ducts 3357 Btuh Ducts 5423 Btuh Central vent (42 cfm) 1298 Btuh Central vent (42 cfm) 695 Btuh Outside air Outside air Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 26975 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 25855 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 3149 Btuh Ducts 1565 Btuh Central vent (42 cfm) 1762 Btuh Heatingg Coolingg Outside air Area(ft2) 1917 1917 Equipment latent load 6476 Btuh Volume (ft3) 16870 16870 Air changes/hour 0.38 0.20 Equipment Total Load (Seril 32331 Btuh Equiv. AVF (cfm) 107 56 Req. total capacity at 0.81 SHR 2.7 ton Heating Equipment Summary Cooling Equipment Summary Make CARRIER Make CARRIER Trade Trade Model 10 KW Cond CA16NA037 AHRI ref Coil FX4DNF037 AHRI ref Efficiency 100 EFF Efficiency 16 SEER Heating input 7.9 kW Sensible cooling 28500 Btuh Heating output 26975 Btuh Latent cooling 6700 Btuh Temperature rise 20 OF Total cooling 35200 Btuh Actual air flow 1200 cfm Actual air flow 1200 cfm Air flow factor 0.047 cfm/Btuh Air flow factor 0.045 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.81 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. w riQ"tsoft" 2021-Jun-15 16:16:07 ^--I , . 11--.1..,,ill,., Right-Suite@ Universal 2019 19.0.12 RSU08398 Page 1 ACCA S:\PROJECTS ENERGY\A-MANUAL J\KHOV-LELIA-PSL.rup Cale=MJ8 Front Door faces: N Right-JO Worksheet Job: w Entire House Date: . ... . . .. ... By: LINDSTROM Lindstrom Air Conditioning 3581 W MCNAB RD, POMPANO BEACH, FL 33069 Phone:954-421-4117 Fax:954-420-0064 Web:www.lindstromair.com 1 Room name Entire House EXT STE LIV PLUS 2 Exposed wall 207.0 ft 46.0 ft 3 Room height 8.8 ft 8.8 ft heat/cool 4 Room dimensions 13.3 x 15.0 ft 5 Room area 1917.0 ft2 199.3 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2-0F) (Btu ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V�l13A-4ocs 0.143 ne 4.00 2.19 428 398 1594 871 0 0 0 0 1 D-h2om 0.870 ne 0.00 0.00 0 0 0 0 0 0 0 0 1 D-h2om 0.870 ne 24.36 43.19 30 0 731 1296 0 0 0 0 13A-4ocs 0.143 se 4.00 2.19 167 123 492 269 108 85 340 186 1 1 1 D-h2om 0.870 se 24.36 39.72 23 8 560 914 23 4 560 914 D 11 DO 0.390 se 10.92 10.34 21 21 229 217 0 0 0 0 13A-4ocs 0.143 sw 4.00 2.19 595 513 2054 1122 153 132 529 289 1 D-h2om 0.870 sw 0.00 0.00 0 0 0 0 0 0 0 0 1 D-h2om 0.870 sw 24.36 39.72 15 5 365 596 0 0 0 0 i D-h2om 0.870 sw 24.36 39.72 23 8 560 914 0 0 0 0 1 D-h2om 0.870 sw 0.00 0.00 0 0 0 0 0 0 0 0 1 D-h2om 0.870 sw 24.36 22.27 23 46 560 512 0 0 0 0 D 11 DO 0.390 sw 10.92 10.34 21 21 229 217 21 21 229 217 13A-4ocs 0.143 nw 4.00 2.19 316 228 913 499 0 0 0 0 1 D-h2om 0.870 nw 0.00 0.00 0 0 0 0 0 0 0 0 1 D-h2om 0.870 nw 24.36 43.19 46 0 1121 1987 0 0 0 0 1 D-h2omd 0.870 nw 0.00 0.00 0 0 0 0 0 0 0 0 1 D-h2omd 0.870 nw 24.36 43.19 42 0 1023 1814 0 0 0 0 1213-0sw 0.097 - 2.72 1.33 357 335 910 445 153 153 416 203 D 11 DO 0.390 ne 10.92 10.34 22 22 240 227 0 0 0 0 C 1613-30ad 0.032 se 0.90 1.60 1917 1917 1718 3067 199 199 179 319 F 22A-tpl 0.989 27.69 0.00 1 91 7 207 5732 0 199 46 1274 0 6 c)AED excursion 1883 210 Envelope loss/gain 19032 16850 3526 2337 12 a) Infiltration 3288 927 570 161 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 4 920 0 0 Appliances/other 2400 0 Subtotal(lines 6 to 13) 22320 21097 4096 2498 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 22320 21097 4096 2498 15 Duct loads 15% 26% 3357 5423 15% 27% 622 663 Total room load 25677 26521 4719 3160 Air required(cfm) 1200 1200 221 143 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. _ wry tsoft 2021-Jun-1516:16:07 ACCA Right-Suite@ Universal 2019 19.0.12 RSU08398 Page 1 S:\PROJECTS ENERGY\A-MANUAL J\KHOV-LELIA-PSL.rup Calc=MJ8 Front Door faces: N Right-JO Worksheet Job: w Entire House Date: . ... . . .. ... By: LINDSTROM Lindstrom Air Conditioning 3581 W MCNAB RD, POMPANO BEACH, FL 33069 Phone:954-421-4117 Fax:954-420-0064 Web:www.lindstromair.com 1 Room name WIC STE PLS BED EX STE PLUS BED 2 Exposed wall 4.5 it 8.5 it 3 Room height 8.8 it heat/cool 8.8 it heat/cool 4 Room dimensions 5.0 x 5.0 it 12.0 x 11.0 it 5 Room area 25.0 ft2 132.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2-0F) (Btuh/ft2) or perimeter (it) (Btuh) or perimeter (it) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6V�l13A-4ocs 0.143 ne 4.00 2.19 0 0 0 0 0 0 0 0 1 D-h2om 0.870 ne 0.00 0.00 0 0 0 0 0 0 0 0 1 D-h2om 0.870 ne 24.36 43.19 0 0 0 0 0 0 0 0 1.1 VL13A-4ocs 0.143 se 4.00 2.19 0 0 0 0 0 0 0 0 G 1 D-h2om 0.870 se 24.36 39.72 0 0 0 0 0 0 0 0 D 11 DO 0.390 se 10.92 10.34 0 0 0 0 0 0 0 0 13A-4ocs 0.143 sw 4.00 2.19 0 0 0 0 77 54 216 118 1 D-h2om 0.870 sw 0.00 0.00 0 0 0 0 0 0 0 0 1 D-h2om 0.870 sw 24.36 39.72 0 0 0 0 0 0 0 0 i D-h2om 0.870 sw 24.36 39.72 0 0 0 0 0 0 0 0 1 D-h2om 0.870 sw 0.00 0.00 0 0 0 0 0 0 0 0 1 D-h2om 0.870 sw 24.36 22.27 0 0 0 0 23 23 560 512 D 11 DO 0.390 sw 10.92 10.34 0 0 0 0 0 0 0 0 13A-4ocs 0.143 nw 4.00 2.19 0 0 0 0 0 0 0 0 1 D-h2om 0.870 nw 0.00 0.00 0 0 0 0 0 0 0 0 1 D-h2om 0.870 nw 24.36 43.19 0 0 0 0 0 0 0 0 1 D-h2omd 0.870 nw 0.00 0.00 0 0 0 0 0 0 0 0 1 D-h2omd 0.870 nw 24.36 43.19 0 0 0 0 0 0 0 0 1213-0sw 0.097 - 2.72 1.33 41 41 111 54 0 0 0 0 D 11 DO 0.390 ne 10.92 10.34 0 0 0 0 0 0 0 0 C 1613-30ad 0.032 se 0.90 1.60 25 25 22 40 132 132 118 211 F 22A-tpl 0.989 27.69 0.00 25 5 125 0 132 9 235 0 6 c)AED excursion -5 561 Envelope loss/gain 258 90 1130 1403 12 a) Infiltration 0 0 168 47 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 258 90 1298 1450 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 258 90 1298 1450 15 Duct loads 15/ 27% 39 24 13% 15% 162 211 Total room load 298 114 1461 1661 Air required(cfm) 14 5 68 75 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. _ wry tsoft 2021-Jun-1516:16:07 ACCA Right-Suite@ Universal 2019 19.0.12 RSU08398 Page 2 S:\PROJECTS ENERGY\A-MANUAL J\KHOV-LELIA-PSL.rup Calc=MJ8 Front Door faces: N Right-JO Worksheet Job: w Entire House Date: . ... . . .. ... By: LINDSTROM Lindstrom Air Conditioning 3581 W MCNAB RD, POMPANO BEACH, FL 33069 Phone:954-421-4117 Fax:954-420-0064 Web:www.lindstromair.com 1 Room name EX STE BATH FOYER 2 Exposed wall 0 ft 19.0 ft 3 Room height 8.8 ft heat/cool 8.8 ft heat/cool 4 Room dimensions 9.0 x 6.0 ft 12.5 x 6.5 ft 5 Room area 54.0 ft2 81.3 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2-0F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6V�l13A-4ocs 0.143 ne 4.00 2.19 0 0 0 0 0 0 0 0 1 D-h2om 0.870 ne 0.00 0.00 0 0 0 0 0 0 0 0 1 D-h2om 0.870 ne 24.36 43.19 0 0 0 0 0 0 0 0 1.1 VL13A-4ocs 0.143 se 4.00 2.19 0 0 0 0 59 38 152 83 G 1 D-h2om 0.870 se 24.36 39.72 0 0 0 0 0 0 0 0 D 11 DO 0.390 se 10.92 10.34 0 0 0 0 21 21 229 217 13A-4ocs 0.143 sw 4.00 2.19 0 0 0 0 113 98 392 214 1 D-h2om 0.870 sw 0.00 0.00 0 0 0 0 0 0 0 0 1 D-h2om 0.870 sw 24.36 39.72 0 0 0 0 15 3 365 596 i D-h2om 0.870 sw 24.36 39.72 0 0 0 0 0 0 0 0 1 D-h2om 0.870 sw 0.00 0.00 0 0 0 0 0 0 0 0 1 D-h2om 0.870 sw 24.36 22.27 0 0 0 0 0 0 0 0 D 11 DO 0.390 sw 10.92 10.34 0 0 0 0 0 0 0 0 13A-4ocs 0.143 nw 4.00 2.19 0 0 0 0 0 0 0 0 1 D-h2om 0.870 nw 0.00 0.00 0 0 0 0 0 0 0 0 1 D-h2om 0.870 nw 24.36 43.19 0 0 0 0 0 0 0 0 1 D-h2omd 0.870 nw 0.00 0.00 0 0 0 0 0 0 0 0 1 D-h2omd 0.870 nw 24.36 43.19 0 0 0 0 0 0 0 0 1213-0sw 0.097 - 2.72 1.33 0 0 0 0 0 0 0 0 D 11 DO 0.390 ne 10.92 10.34 0 0 0 0 0 0 0 0 C 1613-30ad 0.032 se 0.90 1.60 54 54 48 86 81 81 73 130 F 22A-tpl 0.989 27.69 0.00 54 0 0 0 81 19 526 0 6 c)AED excursion -4 172 Envelope loss/gain 48 82 1738 1412 12 a) Infiltration 0 0 375 106 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 48 82 2114 1518 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 48 82 2114 1518 15 Duct loads 15% 27% 71 22 15% 27% 321 403 Total room load 56 104 2435 1921 Air required(cfm) 3 5 114 87 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. _ wry tsoft 2021-Jun-1516:16:07 ACCA Right-Suite@ Universal 2019 19.0.12 RSU08398 Page 3 S:\PROJECTS ENERGY\A-MANUAL J\KHOV-LELIA-PSL.rup Calc=MJ8 Front Door faces: N Right-JO Worksheet Job: w Entire House Date: . ... . . .. ... By: LINDSTROM Lindstrom Air Conditioning 3581 W MCNAB RD, POMPANO BEACH, FL 33069 Phone:954-421-4117 Fax:954-420-0064 Web:www.lindstromair.com 1 Room name HALL BATH LAUNDRY 2 Exposed wall 0 ft 7.5 ft 3 Room height 8.8 ft heat/cool 8.8 ft heat/cool 4 Room dimensions 9.0 x 6.0 ft 7.0 x 11.0 ft 5 Room area 54.0 ft2 77.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2-0F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6V�l13A-4ocs 0.143 ne 4.00 2.19 0 0 0 0 0 0 0 0 1 D-h2om 0.870 ne 0.00 0.00 0 0 0 0 0 0 0 0 1 D-h2om 0.870 ne 24.36 43.19 0 0 0 0 0 0 0 0 13A-4ocs 0.143 se 4.00 2.19 0 0 0 0 0 0 0 0 1 1 1 D-h2om 0.870 se 24.36 39.72 0 0 0 0 0 0 0 0 D 11 DO 0.390 se 10.92 10.34 0 0 0 0 0 0 0 0 13A-4ocs 0.143 sw 4.00 2.19 0 0 0 0 0 0 0 0 1 D-h2om 0.870 sw 0.00 0.00 0 0 0 0 0 0 0 0 1 D-h2om 0.870 sw 24.36 39.72 0 0 0 0 0 0 0 0 i D-h2om 0.870 sw 24.36 39.72 0 0 0 0 0 0 0 0 1 D-h2om 0.870 sw 0.00 0.00 0 0 0 0 0 0 0 0 1 D-h2om 0.870 sw 24.36 22.27 0 0 0 0 0 0 0 0 D 11 DO 0.390 sw 10.92 10.34 0 0 0 0 0 0 0 0 13A-4ocs 0.143 nw 4.00 2.19 0 0 0 0 0 0 0 0 1 D-h2om 0.870 nw 0.00 0.00 0 0 0 0 0 0 0 0 1 D-h2om 0.870 nw 24.36 43.19 0 0 0 0 0 0 0 0 1 D-h2omd 0.870 nw 0.00 0.00 0 0 0 0 0 0 0 0 1 D-h2omd 0.870 nw 24.36 43.19 0 0 0 0 0 0 0 0 1213-0sw 0.097 - 2.72 1.33 0 0 0 0 68 46 125 61 D 11 DO 0.390 ne 10.92 10.34 0 0 0 0 22 22 240 227 C 1613-30ad 0.032 se 0.90 1.60 54 54 48 86 77 77 69 123 F 22A-tpl 0.989 27.69 0.00 54 0 0 0 77 8 208 0 6 c)AED excursion -4 -81 Envelope loss/gain 48 82 642 331 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 1200 Subtotal(lines 6 to 13) 48 82 642 1531 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 48 82 642 1531 15 Duct loads 15% 27% 7 22 15% 27% 98 406 Total room load 56 104 739 1937 Air required(cfm) 3 5 35 88 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. _ wry tsoft 2021-Jun-1516:16:07 ACCA Right-Suite@ Universal 2019 19.0.12 RSU08398 Page 4 S:\PROJECTS ENERGY\A-MANUAL J\KHOV-LELIA-PSL.rup Calc=MJ8 Front Door faces: N Right-JO Worksheet Job: w Entire House Date: . ... . . .. ... By: LINDSTROM Lindstrom Air Conditioning 3581 W MCNAB RD, POMPANO BEACH, FL 33069 Phone:954-421-4117 Fax:954-420-0064 Web:www.lindstromair.com 1 Room name BED 3 BED 2 2 Exposed wall 22.5 ft 12.5 ft 3 Room height 8.8 ft heat/cool 8.8 ft heat/cool 4 Room dimensions 10.5 x 12.0 ft 10.5 x 12.0 ft 5 Room area 126.0 ft2 126.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2-0F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V�l13A-4ocs 0.143 ne 4.00 2.19 108 93 372 203 108 93 372 203 1 D-h2om 0.870 ne 0.00 0.00 0 0 0 0 0 0 0 0 1 D-h2om 0.870 ne 24.36 43.19 15 0 365 648 15 0 365 648 13A-4ocs 0.143 se 4.00 2.19 0 0 0 0 0 0 0 0 1 1 1 D-h2om 0.870 se 24.36 39.72 0 0 0 0 0 0 0 0 D 11 DO 0.390 se 10.92 10.34 0 0 0 0 0 0 0 0 13A-4ocs 0.143 sw 4.00 2.19 0 0 0 0 0 0 0 0 1 D-h2om 0.870 sw 0.00 0.00 0 0 0 0 0 0 0 0 1 D-h2om 0.870 sw 24.36 39.72 0 0 0 0 0 0 0 0 i D-h2om 0.870 sw 24.36 39.72 0 0 0 0 0 0 0 0 1 D-h2om 0.870 sw 0.00 0.00 0 0 0 0 0 0 0 0 1 D-h2om 0.870 sw 24.36 22.27 0 0 0 0 0 0 0 0 D 11 DO 0.390 sw 10.92 10.34 0 0 0 0 0 0 0 0 13A-4ocs 0.143 nw 4.00 2.19 0 0 0 0 0 0 0 0 1 D-h2om 0.870 nw 0.00 0.00 0 0 0 0 0 0 0 0 1 D-h2om 0.870 nw 24.36 43.19 0 0 0 0 0 0 0 0 1 D-h2omd 0.870 nw 0.00 0.00 0 0 0 0 0 0 0 0 1 D-h2omd 0.870 nw 24.36 43.19 0 0 0 0 0 0 0 0 1213-0sw 0.097 - 2.72 1.33 95 95 258 126 0 0 0 0 D 11 DO 0.390 ne 10.92 10.34 0 0 0 0 0 0 0 0 C 1613-30ad 0.032 se 0.90 1.60 126 126 113 202 126 126 113 202 F 22A-tpl 0.989 27.69 0.00 126 23 623 0 126 13 346 0 6 c)AED excursion -74 -68 Envelope loss/gain 1732 1105 1197 985 12 a) Infiltration 236 66 236 66 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 1 230 1 230 Appliances/other 0 0 Subtotal(lines 6 to 13) 1968 1401 1433 1282 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1968 1401 1433 1282 15 Duct loads 15% 27% 2991 372 15% 27% 218 340 Total room load 2267 1773 1650 1622 Air required(cfm) 106 80 77 73 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. _ wry tsoft 2021-Jun-1516:16:07 ACCA Right-Suite@ Universal 2019 19.0.12 RSU08398 Page 5 S:\PROJECTS ENERGY\A-MANUAL J\KHOV-LELIA-PSL.rup Calc=MJ8 Front Door faces: N Right-JO Worksheet Job: w Entire House Date: . ... . . .. ... By: LINDSTROM Lindstrom Air Conditioning 3581 W MCNAB RD, POMPANO BEACH, FL 33069 Phone:954-421-4117 Fax:954-420-0064 Web:www.lindstromair.com 1 Room name KIT GREAT RM DIN M BATH 2 Exposed wall 43.5 ft 9.0 ft 3 Room height 8.8 ft heat/cool 8.8 ft heat/cool 4 Room dimensions 24.0 x 28.0 ft 9.0 x 10.5 ft 5 Room area 672.0 ft2 94.5 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2-0F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V�l13A-4ocs 0.143 ne 4.00 2.19 0 0 0 0 81 81 324 177 1 D-h2om 0.870 ne 0.00 0.00 0 0 0 0 0 0 0 0 1 D-h2om 0.870 ne 24.36 43.19 0 0 0 0 0 0 0 0 1.1 VL13A-4ocs 0.143 se 4.00 2.19 0 0 0 0 0 0 0 0 G 1 D-h2om 0.870 se 24.36 39.72 0 0 0 0 0 0 0 0 D 11 DO 0.390 se 10.92 10.34 0 0 0 0 0 0 0 0 13A-4ocs 0.143 sw 4.00 2.19 252 229 917 501 0 0 0 0 1 D-h2om 0.870 sw 0.00 0.00 0 0 0 0 0 0 0 0 1 D-h2om 0.870 sw 24.36 39.72 0 0 0 0 0 0 0 0 i D-h2om 0.870 sw 24.36 39.72 23 4 560 914 0 0 0 0 1 D-h2om 0.870 sw 0.00 0.00 0 0 0 0 0 0 0 0 1 D-h2om 0.870 sw 24.36 22.27 0 0 0 0 0 0 0 0 D 11 DO 0.390 sw 10.92 10.34 0 0 0 0 0 0 0 0 13A-4ocs 0.143 nw 4.00 2.19 140 75 300 164 0 0 0 0 1 D-h2om 0.870 nw 0.00 0.00 0 0 0 0 0 0 0 0 1 D-h2om 0.870 nw 24.36 43.19 23 0 560 993 0 0 0 0 1 D-h2omd 0.870 nw 0.00 0.00 0 0 0 0 0 0 0 0 1 D-h2omd 0.870 nw 24.36 43.19 42 0 1023 1814 0 0 0 0 1213-0sw 0.097 - 2.72 1.33 0 0 0 0 0 0 0 0 D 11 DO 0.390 ne 10.92 10.34 0 0 0 0 0 0 0 0 C 1613-30ad 0.032 se 0.90 1.60 672 672 602 1075 95 95 85 151 F 22A-tpl 0.989 27.69 0.00 672 44 1205 0 95 9 249 0 6 c)AED excursion 988 -19 Envelope loss/gain 5168 6449 658 309 12 a) Infiltration 856 241 177 50 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 1200 0 Subtotal(lines 6 to 13) 6023 7890 835 359 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 6023 7890 835 359 15 Duct loads 15% 27% 915 2093 15% 27% 127 95 Total room load 6939 9984 962 455 Air required(cfm) 324 452 45 21 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. _ wry tsoft 2021-Jun-1516:16:07 ACCA Right-Suite@ Universal 2019 19.0.12 RSU08398 Page 6 S:\PROJECTS ENERGY\A-MANUAL J\KHOV-LELIA-PSL.rup Calc=MJ8 Front Door faces: N Right-JO Worksheet Job: w Entire House Date: . ... . . .. ... By: LINDSTROM Lindstrom Air Conditioning 3581 W MCNAB RD, POMPANO BEACH, FL 33069 Phone:954-421-4117 Fax:954-420-0064 Web:www.lindstromair.com 1 Room name MASTER SUITE MASTER WIC 2 Exposed wall 28.0 ft 6.0 ft 3 Room height 8.8 ft heat/cool 8.8 ft heat/cool 4 Room dimensions 15.0 x 14.0 ft 11.0 x 6.0 ft 5 Room area 210.0 ft2 66.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2-0F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V�l13A-4ocs 0.143 ne 4.00 2.19 131 131 525 287 0 0 0 0 1 D-h2om 0.870 ne 0.00 0.00 0 0 0 0 0 0 0 0 1 D-h2om 0.870 ne 24.36 43.19 0 0 0 0 0 0 0 0 1.1 VL13A-4ocs 0.143 se 4.00 2.19 0 0 0 0 0 0 0 0 G 1 D-h2om 0.870 se 24.36 39.72 0 0 0 0 0 0 0 0 D 11 DO 0.390 se 10.92 10.34 0 0 0 0 0 0 0 0 13A-4ocs 0.143 sw 4.00 2.19 0 0 0 0 0 0 0 0 1 D-h2om 0.870 sw 0.00 0.00 0 0 0 0 0 0 0 0 1 D-h2om 0.870 sw 24.36 39.72 0 0 0 0 0 0 0 0 i D-h2om 0.870 sw 24.36 39.72 0 0 0 0 0 0 0 0 1 D-h2om 0.870 sw 0.00 0.00 0 0 0 0 0 0 0 0 1 D-h2om 0.870 sw 24.36 22.27 0 0 0 0 0 0 0 0 D 11 DO 0.390 sw 10.92 10.34 0 0 0 0 0 0 0 0 13A-4ocs 0.143 nw 4.00 2.19 122 99 396 217 54 54 216 118 1 D-h2om 0.870 nw 0.00 0.00 0 0 0 0 0 0 0 0 1 D-h2om 0.870 nw 24.36 43.19 23 0 560 993 0 0 0 0 1 D-h2omd 0.870 nw 0.00 0.00 0 0 0 0 0 0 0 0 1 D-h2omd 0.870 nw 24.36 43.19 0 0 0 0 0 0 0 0 1213-0sw 0.097 - 2.72 1.33 0 0 0 0 0 0 0 0 D 11 DO 0.390 ne 10.92 10.34 0 0 0 0 0 0 0 0 C 1613-30ad 0.032 se 0.90 1.60 210 210 188 336 66 66 59 106 F 22A-tpl 0.989 27.69 0.00 210 28 775 0 66 6 166 0 6 c)AED excursion 221 -13 Envelope loss/gain 2445 2054 442 211 12 a) Infiltration 552 156 118 33 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 2997 2670 559 244 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 2997 2670 559 244 15 Duct loads 15% 27% 455 708 15% 27% 85 65 Total room load _T 3452 3378 644 309 Air required(cfm) 161 153 30 14 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. _ wry tsoft 2021-Jun-1516:16:07 ACCA Right-Suite@ Universal 2019 19.0.12 RSU08398 Page 7 S:\PROJECTS ENERGY\A-MANUAL J\KHOV-LELIA-PSL.rup Calc=MJ8 Front Door faces: N