HomeMy WebLinkAboutAPPROVED REVISION , ENERGY LOT 38 (1)FORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: KHOV-EDEN
Builder Name: KHOVNANAIN HOMES
Street: 5137 ARMINA PLACE
Permit Office:
City, State, Zip: FT PIERCE. FL,
Permit Number:
Owner: EDEN MODEL LOT 38 @ WATERSTONE
Jurisdiction:
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
10. Wall Type$1796.7 sqft.) Insulation Area
2. Single family or multiple family Detached
a. Concrete Block - lnt Insul, Exterior R=4.1 1516.70 ft2
3. Number of units, if multiple family 1
b. Frame - Wood, Adjacent R=11.0 280.00 ft2
c. NIA R= ft2
4. Number of Bedrooms 4
d. N/A R= ft2
5. Is this a worst case? No
11. Ceiling Types (161 &0 sqft.) Insulation Area
a. Under Attic (Vented) R=30.0 1618.00 ft2
6. Conditioned floor area above grade (ft2) 1616
b. WA R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A R= ft2
7. Windows(154.9 sqft.) Description Area
12. Ducts R ft2
a. U-Factor: Dbl, U=0.28 113.92 ft2
a. Sup: Attic, Ret: HALL BATH, AH: HALL BATH 6 300
SHGC: SHGC=0.30
b. U-Factor: Dbl, U=0.55 41.00 ft2
13. Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.34
a. Central Unit 29.4 SEER:16.00
c. U-Factor: NIA ftz
SHGC:
Area Weighted Average Overhang Depth: 4.909 ft.
14. Heating systems kBtulhr Efficiency
Area Weighted Average SHGC: 0.311
a. Electric Strip Heat 23.0 COPA.00
8. Skylights Area
c. U-Factor:(AVG) N/A ft2
15. Hot water systems
SHGC(AVG): NIA
a. Electric Cap: 40 gallons
9. Floor Types (1616.0 sqft.) Insulation Area
EF: 0.950
a. Slab -On -Grade Edge Insulation R=0.0 1616.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
16. Credits Pstat
Glass/Floor Area: 0.096 Total Proposed Modified Loads: 54.01 PASS
Total Baseline Loads: 55,24
1 hereby certify that the plans and sp ifications covered by
Review of the plans and V14E S7,,1
this calculation are in compliance wit i the Florida Energy
specifications covered by this AV = Ct
Code.
calculation indicates complianceff„ff`l
h ]
with the Florida Energy Code. 10„
PREPARED BY:
Before construction is completed r1
DATE: `
this building will be inspected for W.
compliance with Section 553.908 * "T
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Energy Code.
CC),) Wt
OWNER/AGENT:
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
6/15/2021 6:01 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Pagel of 5
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: KHOV-EDEN Bedrooms: 4
Address Type:
Street Address
Building Type: User Conditioned Area: 1616
Lot #
Owner Name: EDEN MODEL LOT 38 @ W Total Stories: 1
Block/Subdivision:
# of Units: 1 Worst Case: No
PlatBook:
Builder Name: KHOVNANAIN HOMES Rotate Angle: 0
Street:
5137 ARM INA PLACE
Permit Office: Cross Ventilation: No
County:
St. Lucie
Jurisdiction: Whole House Fan: No
City, State, Zip:
FT PIERCE,
Family Type: Detached
FL
New/Existing: New (From Plans)
Comment:
CLIMATE
/ Design Temp
Int Design Temp Heating
Design Daily Temp
V Design Location TMY Site 97.5 % 2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90
70
75 299
62
Low
BLOCKS
Number Name Area Volume
1 Entire House 1616 14220.8
SPACES
Number Name Area Volume Kitchen Occupants
Bedrooms
InfilID Finished Cooled
Heated
1 BED 3 161 1416.8 No 1
4
1 No
Yes
Yes
2 HALL BATH 77 678 No 0
1 No
Yes
Yes
3 FOYER 172 1514 No 0
1 No
Yes
Yes
4 BED 4 149 1307 No 1
1 No
Yes
Yes
5 LAUNDRY 52 458 No 0
1 No
Yes
Yes
6 BED 2 149 1307 No 1
1 No
Yes
Yes
7 GRT DIN KITCHEN 550 4840 No 0
1 No
Yes
Yes
8 MASTER SUITE 176 1544 No 2
1 No
Yes
Yes
9 MAST WIC 58 506 No 0
1 No
Yes
Yes
10 M BATH 72 634 No 0
1 No
Yes
Yes
FLOORS
# Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio BED 3 38 ft 0
163 ft2
____
0 1
0
2 Slab -On -Grade Edge Insulatio HALL BATH 11 ft 0
77 ft2
____
1 0
0
3 Slab -On -Grade Edge Insulatio FOYER 25 ft 0
172 ft2
____
1 0
0
4 Slab -On -Grade Edge Insulatio BED 4 14 ft 0
148,5 ft2
__--
0 1
0
5 Slab -On -Grade Edge Insulatio LAUNDRY 1 ft 0
52 ft2
____
1 0
0
6 Slab -On -Grade Edge Insulatio BED 2 13.5 ft 0
148.5 ft2
____
0 1
0
7 Slab -On -Grade Edge Insulatio GIRT DIN KITCHE 49 ft 0
550 ft2
___-
0.5 0.5
0
6/15/2021 6:01 PM EnergyGauge(D USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 5
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood Carpet
8 Slab -On -Grade Edge Insulatio MASTER SUITE 26.5 ft 0
175.5 ft2
----
0 1 0
9 Slab -On -Grade Edge Insulatio MAST WIC 11.5 ft 0
57.5 ft2
--__
0 1 0
10SIab-On-Grade Edge Insulatio M BATH 1 ft 0
72 ftz
-__-
1 0 0
ROOF
/ Roof Gable Roof
Rad
Solar SA Emitt
Emitt Deck Pitch
v # Type Materials Area Area Color
Barr
Absor. Tested
Tested Insul. (deg)
1 Hip Composition shingles 1750 ft2 0 ft2 Medium
N
0.9 No 0.9
No 0 22.6
ATTIC
V
#
Type Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1
Full attic Vented
150
1616 ft2
N
N
CEILING
#
Ceiiing Type Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1
Under Attic (Vented) BED 3
30
Blown
163 ftz
0.1
Wood
2
Under Attic (Vented) HALL BATH
30
Blown
77 ftz
0.1
Wood
3
Under Attic (Vented) FOYER
30
Blown
172 ftz
0.1
Wood
4
Under Attic (Vented) BED 4
30
Blown
149 ft2
0.1
Wood
5
Under Attic (Vented) LAUNDRY
30
Blown
52 ft2
0.1
Wood
6
Under Attic (Vented) BED 2
30
Blown
149 ft2
0.1
Wood
7
Under Attic (Vented) GIRT DIN KITCHE
30
Blown
550 ft2
0.1
Wood
8
Under Attic (Vented) MASTER SUITE
30
Blown
176 tifat
0.1
Wood
9
Under Attic (Vented) MAST WIC
30
Blown
58 ftz
0.1
Wood
10
Under Attic (Vented) M BATH
30
Blown
72 ft2
0.1
Wood
WALLS
Adjacent Space Cavity
-
Width
Height
Sheathing Framing Solar
Below
a
1
NE
Exterior Concrete Block - Int Insul BED 3
4.1
13
1 9
4
122.1 ftz
0
0
0.5
0
2
SE
Exterior Concrete Block - Int Insul BED 3
4.1
10
8 9
4
99.6 ft2
0
0
0.5
0
3
SW
Exterior Concrete Block - Int Insul BED 3
4.1
12
2 10
0
121.7 ftz
0
0
0.5
0
4
SW
Exterior Concrete Block - Int InsLHIALL BATH
4.1
9
11 10
0
99.2 ft2
0
0
0.5
0
5
SE
Exterior Concrete Block - Int Insul FOYER
4.1
4
10 9
4
45.1 ft2
0
0
0.5
0
6
SW
Exterior Concrete Block- Int Insul BED 4
4.1
12
7 10
0
125.8 ftz
0
0
0.5
0
7
NE
Exterior Concrete Block- Int Insul BED 2
4.1
13
1 9
4
122.1 ft2
0
0
0.5
0
8
SW
Exterior Concrete Block - Int InsGRT DIN KIT
4.1
22
6 10
0
225.0 ft2
0
0
0.5
0
9
NW
Exterior Concrete Block - Int InsIRRT DIN KIT
4.1
23
3 9
4
217.0 ftz
0
0
0.5
0
10
NE
Exterior Concrete Block - Int InsMASTER SUI
4.1
12
7 9
4
117.4 ftz
0
0
0.5
0
11
NW
Exterior Concrete Block - Int InsMASTER SUI
4.1
12
7 9
4
117.4 ft2
0
0
0.5
0
12
NE
Exterior Concrete B€ock - Int InsuMAST WIC
4.1
11
2 9
4
104.2 ft2
0
0
0.5
0
6/15/2021 6:01 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 5
FORM R405-2020
INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Space Cavity Width Height
-
Sheathing Framing Solar Below
a
13 NW
Garage Frame - Wood GRT DIN KIT 11 30 0 9 4 280.0 ft2
0 0 0.5
0
DOORS
#
Ornt
Door Type Space Storms U-Value
Width Height
Area
Ft
In Ft In
1
NW
Insulated GIRT DIN KIT None .46 3
8
24 ft2
2
NW
Wood GIRT DIN KIT None .46 2.8 8
22.4 ft2
WINDOWS
Orientation shown is the entered. Proposed orientation.
/
Wall
Overhang
V #
Ornt ID Frame
Panes NFRC U-Factor SHGC Imp Area Depth
Separation Int Shade
Screening
1
SE 2 Metal
Double (Tinted) Yes 0.28 0.3 N 15.0 ft' 1 ft 0 in
1 ft 0 in None
None
2
SW 6 Meta[
Double (Tinted) Yes 0.28 0.3 N 15.0 ft2 1 ft 0 in
1 ft 0 in None
None
3
NE 7 Metal
Double (Tinted) Yes 0.28 0.3 N 15.0 ft2 1 ft O in
1 ft 0 in None
None
4
SW 8 Metal
Double (Tinted) Yes 0.55 0.34 N 41.0 ft2 11 ft 0 in
1 ft 0 in None
None
5
NW 9 Metal
Double (Tinted) Yes 0.28 0.3 N 23.0 ft2 1 ft 0 in
1 ft 0 in None
None
6
NW 9 Metal
Double (Tinted) Yes 0.28 0.3 N 23.0 ft2 9 ft 6 in
1 ft 0 in None
None
7
NW 11 Metal
Double (Tinted) Yes 0.28 0.3 N 22.9 ft' 1 ft 0 in
1 ft 0 in None
None
GARAGE
#
Floor Area
Ceiling Area Exposed Wall Perimeter Avg. Wall Height
Exposed Wall Insulation
1
380 ft2
380 ft2 64 ft 8 ft
1
INFILTRATION
# Scope
Method
SLA CFM 50 ELA EgLA ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000391 1657.2 90.92 170.69 .1312
7
HEATING SYSTEM
#
System Type
Subtype Speed Efficiency Capacity
Block
Ducts
1
Electric Strip Heat/ None COP:1 23 kBtulhr
1
sys#1
COOLING SYSTEM
#
System Type
Subtype Subtype Efficiency Capacity Air Flow SHR Block
Ducts
1
Central Unit/
Split Singl SEER: 16 29.4 kBtulhr
cfm 0.71 1
sys#1
6/15/2021 6:01 PM EnergyGaugeV USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 5
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
HOT WATER SYSTEM
# System Type SubType Location EF Cap Use SetPnt Conservation
1 Electric None Garage 0A5 40 gal 60.9 gal 120 deg Ncne
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cert # Company Name System Model # Collector Model # Area Volume FEF
None None ft2
DUCTS
/ ---- Supply ----
----
Return ----
Air
CFM 25
CFM25
HVAC #
1/ # Location R-Value Area
Location
Area
Leakage Type
Handler
TOT
OUT ON
RLF
Heat Cool
1 Attic
6 300 ft2
HALL BATH
1 ft2
Default Leakage
HALL BAT
(Default)
(Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Cooling
Heating
Jan
f X� Jan
Feb
Feb
Mar
f X Mar
jXj
A r
Ma
X Jun
X Jul
X Au
X Se
S
Oct
Nov
NovSep
Dec
X
Venting
lX
[ Jan [
Feb
X Mar
Apr
May
Jun
Jul
Aug
X
Oct
Nov
DDec
ec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9 10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80 80
80
80
PM
80
80
78
78
78
78
78
78
78 78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
78 78
78
78
PM
78
78
78
78
78
78
78
78
78 78
78
78
Heating (VVD)
AM
66
66
66
66
66
68
68
68
68 68
68
68
PM
68
68
68
68
68
68
68
68
68 68
66
66
Heating (WEH)
AM
66
66
66
66
66
68
68
68
68 68
68
68
PM
68
68
68
68
68
68
68
68
68 68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibslsq.ft.
0 ft2
0 ft
0.3
BED 2
Default(8 Ibslsq.ft.
ft2
ft
0.3
BATH 2
Default(8 Ibslsq.ft.
ft2
ft
0.3
LAUNDRY
Default(8 Ibslsq.ft.
ff2
ft
0.3
KITCHEN
Default(8 Ibslsq.ft,
ft2
ft
0.3
GREAT ROOM
Default(8 Ibs/sq.ft.
ft2
ft
0.3
WIC MASTER
Default(8 Ibslsq.ft.
ft2
ft
0.3
MASTER BATH
Default(8 Ibs/sq.ft.
ft2
ft
0.3
TIOLET MASTER
Default(8 Ibslsq.ft.
ft2
ft
0.3
MASTER SUITE
6/15/2021 6:01 PM EnergyGaugeO USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 of 5
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 98
The lower the EnergyPerformance Index, the more efficient the home.
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. is this a worst case?
6. Conditioned floor area (ft2)
7. Windows" Description
a. U-Factor: Dbl, U=0.28
SHGC: SHGC=0.30
b. U-Factor: Dbl, U=0.55
SHGC: SHGC=0.34
c. U-Factor: NIA
SHGC:
d. U-Factor: NIA
SHGC-
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
8. Skylights Description
a_ U-Factor(AVG): NIA
SHGC(AVG): N/A
9. Floor Types
a. Slab -On -Grade Edge Insulation
b. NIA
c. N/A
5137 ARM] NA PLACE, FT PIERCE, FL,
New (From Plans)
10. Wall Type and Insulation
Insulation
Area
Detached
a. Concrete Block - Int Insul, Exterior
R=4.1
1516.70 ft2
b. Frame - Wood, Adjacent
R=11.0
280.00 ft2
1
c. NIA
R=
ft2
4
d. NIA
R=
ft2
No
11. Ceiling Type and insulation level
Insulation
Area
a. Under Attic (Vented)
R=30.0
1616,00 ft2
1616
b. NIA
R=
ft2
Area
c. NIA
R=
ft2
113.92 ft2
12. Ducts, location & insulation level
R ft2
a. Sup: Attic, Ret: HALL BATH, AH: HALL
BATH
6 300
41.00 ft2
13. Cooling systems
kBtu/hr
Efficiency
ft2
a. Central Unit
29.4 SEER:16.00
ftZ
4.909 ft.
0.311
Area
ft2
Insulation Area
R=0.0 1616.00 ft2
R= ft2
R= ft2
14. Heating systems
a. Electric Strip Heat
15. Hot water systems
a. Electric
b. Conservation features
None
Credits (Performance method)
certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature:
Address of New Home:
Date:
City/FL Zip:
kBtu/hr Efficiency
23.0 COP:1.00
Cap: 40 gallons
EF: 0.95
Pstat
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
6/15/2021 6:01 PM EnergyGaugeO USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1