HomeMy WebLinkAboutAPPROVED REVISION , ENERGY LOT 38 (1)FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: KHOV-EDEN Builder Name: KHOVNANAIN HOMES Street: 5137 ARMINA PLACE Permit Office: City, State, Zip: FT PIERCE. FL, Permit Number: Owner: EDEN MODEL LOT 38 @ WATERSTONE Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall Type$1796.7 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - lnt Insul, Exterior R=4.1 1516.70 ft2 3. Number of units, if multiple family 1 b. Frame - Wood, Adjacent R=11.0 280.00 ft2 c. NIA R= ft2 4. Number of Bedrooms 4 d. N/A R= ft2 5. Is this a worst case? No 11. Ceiling Types (161 &0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1618.00 ft2 6. Conditioned floor area above grade (ft2) 1616 b. WA R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 7. Windows(154.9 sqft.) Description Area 12. Ducts R ft2 a. U-Factor: Dbl, U=0.28 113.92 ft2 a. Sup: Attic, Ret: HALL BATH, AH: HALL BATH 6 300 SHGC: SHGC=0.30 b. U-Factor: Dbl, U=0.55 41.00 ft2 13. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.34 a. Central Unit 29.4 SEER:16.00 c. U-Factor: NIA ftz SHGC: Area Weighted Average Overhang Depth: 4.909 ft. 14. Heating systems kBtulhr Efficiency Area Weighted Average SHGC: 0.311 a. Electric Strip Heat 23.0 COPA.00 8. Skylights Area c. U-Factor:(AVG) N/A ft2 15. Hot water systems SHGC(AVG): NIA a. Electric Cap: 40 gallons 9. Floor Types (1616.0 sqft.) Insulation Area EF: 0.950 a. Slab -On -Grade Edge Insulation R=0.0 1616.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 16. Credits Pstat Glass/Floor Area: 0.096 Total Proposed Modified Loads: 54.01 PASS Total Baseline Loads: 55,24 1 hereby certify that the plans and sp ifications covered by Review of the plans and V14E S7,,1 this calculation are in compliance wit i the Florida Energy specifications covered by this AV = Ct Code. calculation indicates complianceff„ff`l h ] with the Florida Energy Code. 10„ PREPARED BY: Before construction is completed r1 DATE: ` this building will be inspected for W. compliance with Section 553.908 * "T I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code. CC),) Wt OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 6/15/2021 6:01 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Pagel of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: KHOV-EDEN Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 1616 Lot # Owner Name: EDEN MODEL LOT 38 @ W Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: KHOVNANAIN HOMES Rotate Angle: 0 Street: 5137 ARM INA PLACE Permit Office: Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FT PIERCE, Family Type: Detached FL New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1616 14220.8 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 BED 3 161 1416.8 No 1 4 1 No Yes Yes 2 HALL BATH 77 678 No 0 1 No Yes Yes 3 FOYER 172 1514 No 0 1 No Yes Yes 4 BED 4 149 1307 No 1 1 No Yes Yes 5 LAUNDRY 52 458 No 0 1 No Yes Yes 6 BED 2 149 1307 No 1 1 No Yes Yes 7 GRT DIN KITCHEN 550 4840 No 0 1 No Yes Yes 8 MASTER SUITE 176 1544 No 2 1 No Yes Yes 9 MAST WIC 58 506 No 0 1 No Yes Yes 10 M BATH 72 634 No 0 1 No Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio BED 3 38 ft 0 163 ft2 ____ 0 1 0 2 Slab -On -Grade Edge Insulatio HALL BATH 11 ft 0 77 ft2 ____ 1 0 0 3 Slab -On -Grade Edge Insulatio FOYER 25 ft 0 172 ft2 ____ 1 0 0 4 Slab -On -Grade Edge Insulatio BED 4 14 ft 0 148,5 ft2 __-- 0 1 0 5 Slab -On -Grade Edge Insulatio LAUNDRY 1 ft 0 52 ft2 ____ 1 0 0 6 Slab -On -Grade Edge Insulatio BED 2 13.5 ft 0 148.5 ft2 ____ 0 1 0 7 Slab -On -Grade Edge Insulatio GIRT DIN KITCHE 49 ft 0 550 ft2 ___- 0.5 0.5 0 6/15/2021 6:01 PM EnergyGauge(D USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 8 Slab -On -Grade Edge Insulatio MASTER SUITE 26.5 ft 0 175.5 ft2 ---- 0 1 0 9 Slab -On -Grade Edge Insulatio MAST WIC 11.5 ft 0 57.5 ft2 --__ 0 1 0 10SIab-On-Grade Edge Insulatio M BATH 1 ft 0 72 ftz -__- 1 0 0 ROOF / Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch v # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 1750 ft2 0 ft2 Medium N 0.9 No 0.9 No 0 22.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1616 ft2 N N CEILING # Ceiiing Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) BED 3 30 Blown 163 ftz 0.1 Wood 2 Under Attic (Vented) HALL BATH 30 Blown 77 ftz 0.1 Wood 3 Under Attic (Vented) FOYER 30 Blown 172 ftz 0.1 Wood 4 Under Attic (Vented) BED 4 30 Blown 149 ft2 0.1 Wood 5 Under Attic (Vented) LAUNDRY 30 Blown 52 ft2 0.1 Wood 6 Under Attic (Vented) BED 2 30 Blown 149 ft2 0.1 Wood 7 Under Attic (Vented) GIRT DIN KITCHE 30 Blown 550 ft2 0.1 Wood 8 Under Attic (Vented) MASTER SUITE 30 Blown 176 tifat 0.1 Wood 9 Under Attic (Vented) MAST WIC 30 Blown 58 ftz 0.1 Wood 10 Under Attic (Vented) M BATH 30 Blown 72 ft2 0.1 Wood WALLS Adjacent Space Cavity - Width Height Sheathing Framing Solar Below a 1 NE Exterior Concrete Block - Int Insul BED 3 4.1 13 1 9 4 122.1 ftz 0 0 0.5 0 2 SE Exterior Concrete Block - Int Insul BED 3 4.1 10 8 9 4 99.6 ft2 0 0 0.5 0 3 SW Exterior Concrete Block - Int Insul BED 3 4.1 12 2 10 0 121.7 ftz 0 0 0.5 0 4 SW Exterior Concrete Block - Int InsLHIALL BATH 4.1 9 11 10 0 99.2 ft2 0 0 0.5 0 5 SE Exterior Concrete Block - Int Insul FOYER 4.1 4 10 9 4 45.1 ft2 0 0 0.5 0 6 SW Exterior Concrete Block- Int Insul BED 4 4.1 12 7 10 0 125.8 ftz 0 0 0.5 0 7 NE Exterior Concrete Block- Int Insul BED 2 4.1 13 1 9 4 122.1 ft2 0 0 0.5 0 8 SW Exterior Concrete Block - Int InsGRT DIN KIT 4.1 22 6 10 0 225.0 ft2 0 0 0.5 0 9 NW Exterior Concrete Block - Int InsIRRT DIN KIT 4.1 23 3 9 4 217.0 ftz 0 0 0.5 0 10 NE Exterior Concrete Block - Int InsMASTER SUI 4.1 12 7 9 4 117.4 ftz 0 0 0.5 0 11 NW Exterior Concrete Block - Int InsMASTER SUI 4.1 12 7 9 4 117.4 ft2 0 0 0.5 0 12 NE Exterior Concrete B€ock - Int InsuMAST WIC 4.1 11 2 9 4 104.2 ft2 0 0 0.5 0 6/15/2021 6:01 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height - Sheathing Framing Solar Below a 13 NW Garage Frame - Wood GRT DIN KIT 11 30 0 9 4 280.0 ft2 0 0 0.5 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 NW Insulated GIRT DIN KIT None .46 3 8 24 ft2 2 NW Wood GIRT DIN KIT None .46 2.8 8 22.4 ft2 WINDOWS Orientation shown is the entered. Proposed orientation. / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 SE 2 Metal Double (Tinted) Yes 0.28 0.3 N 15.0 ft' 1 ft 0 in 1 ft 0 in None None 2 SW 6 Meta[ Double (Tinted) Yes 0.28 0.3 N 15.0 ft2 1 ft 0 in 1 ft 0 in None None 3 NE 7 Metal Double (Tinted) Yes 0.28 0.3 N 15.0 ft2 1 ft O in 1 ft 0 in None None 4 SW 8 Metal Double (Tinted) Yes 0.55 0.34 N 41.0 ft2 11 ft 0 in 1 ft 0 in None None 5 NW 9 Metal Double (Tinted) Yes 0.28 0.3 N 23.0 ft2 1 ft 0 in 1 ft 0 in None None 6 NW 9 Metal Double (Tinted) Yes 0.28 0.3 N 23.0 ft2 9 ft 6 in 1 ft 0 in None None 7 NW 11 Metal Double (Tinted) Yes 0.28 0.3 N 22.9 ft' 1 ft 0 in 1 ft 0 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 380 ft2 380 ft2 64 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000391 1657.2 90.92 170.69 .1312 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 23 kBtulhr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 16 29.4 kBtulhr cfm 0.71 1 sys#1 6/15/2021 6:01 PM EnergyGaugeV USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0A5 40 gal 60.9 gal 120 deg Ncne SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS / ---- Supply ---- ---- Return ---- Air CFM 25 CFM25 HVAC # 1/ # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 300 ft2 HALL BATH 1 ft2 Default Leakage HALL BAT (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cooling Heating Jan f X� Jan Feb Feb Mar f X Mar jXj A r Ma X Jun X Jul X Au X Se S Oct Nov NovSep Dec X Venting lX [ Jan [ Feb X Mar Apr May Jun Jul Aug X Oct Nov DDec ec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (VVD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibslsq.ft. 0 ft2 0 ft 0.3 BED 2 Default(8 Ibslsq.ft. ft2 ft 0.3 BATH 2 Default(8 Ibslsq.ft. ft2 ft 0.3 LAUNDRY Default(8 Ibslsq.ft. ff2 ft 0.3 KITCHEN Default(8 Ibslsq.ft, ft2 ft 0.3 GREAT ROOM Default(8 Ibs/sq.ft. ft2 ft 0.3 WIC MASTER Default(8 Ibslsq.ft. ft2 ft 0.3 MASTER BATH Default(8 Ibs/sq.ft. ft2 ft 0.3 TIOLET MASTER Default(8 Ibslsq.ft. ft2 ft 0.3 MASTER SUITE 6/15/2021 6:01 PM EnergyGaugeO USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 of 5 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the EnergyPerformance Index, the more efficient the home. 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. is this a worst case? 6. Conditioned floor area (ft2) 7. Windows" Description a. U-Factor: Dbl, U=0.28 SHGC: SHGC=0.30 b. U-Factor: Dbl, U=0.55 SHGC: SHGC=0.34 c. U-Factor: NIA SHGC: d. U-Factor: NIA SHGC- Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 8. Skylights Description a_ U-Factor(AVG): NIA SHGC(AVG): N/A 9. Floor Types a. Slab -On -Grade Edge Insulation b. NIA c. N/A 5137 ARM] NA PLACE, FT PIERCE, FL, New (From Plans) 10. Wall Type and Insulation Insulation Area Detached a. Concrete Block - Int Insul, Exterior R=4.1 1516.70 ft2 b. Frame - Wood, Adjacent R=11.0 280.00 ft2 1 c. NIA R= ft2 4 d. NIA R= ft2 No 11. Ceiling Type and insulation level Insulation Area a. Under Attic (Vented) R=30.0 1616,00 ft2 1616 b. NIA R= ft2 Area c. NIA R= ft2 113.92 ft2 12. Ducts, location & insulation level R ft2 a. Sup: Attic, Ret: HALL BATH, AH: HALL BATH 6 300 41.00 ft2 13. Cooling systems kBtu/hr Efficiency ft2 a. Central Unit 29.4 SEER:16.00 ftZ 4.909 ft. 0.311 Area ft2 Insulation Area R=0.0 1616.00 ft2 R= ft2 R= ft2 14. Heating systems a. Electric Strip Heat 15. Hot water systems a. Electric b. Conservation features None Credits (Performance method) certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Address of New Home: Date: City/FL Zip: kBtu/hr Efficiency 23.0 COP:1.00 Cap: 40 gallons EF: 0.95 Pstat *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 6/15/2021 6:01 PM EnergyGaugeO USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1