HomeMy WebLinkAboutBuilding PlansAm �* LBJ Architecture TREATMENT OFFICE r---------------------- I OFFICE U C L L FLOOR PLAN SCALE: 1/4" - 1'-0" WALL LEGEND EXISTING WALLS TO REMAIN NEW INTERIOR FRAMING CBS WALL INFILL �..�. r) IJnI IP7 MATCr11A/AI I 1 11 n(lr- SOUND 6020 4" TUBE STEEL COLUMN SEE DETAIL FOR MORE INFO 6068 STOREFRONT DOOR C.C. TO SPRAY FOAM UNDERSIDE OF ROOF DECK WITH R-20 OPEN CELL WITH FIRESHELL COATING i■ Gilt) i /�A ( /a�' il� A, iii' RAMP UP PLATFORM 6020TRANSOM WINDOW 6020TRANSOM WINDOW 6ENERAL. NOTES 1. CONSTRUCT ALL WORK IN ACCORDANCE W/ ALL APPLICABLE BUILDING CODES & ASTM STANDARDS. 2. CONTRACTOR SHALL VISIT THE SITE AND FAMILIARIZE HIMSELF WITH THE EXISTING CONDITIONS AND NOTIFY THE ARCHITECT OF ANY OBSERVED DISCREPANCIES PRIOR TO CONSTRUCTION. 3. DO NOT SCALE DRAWINGS. 4. THE DRAWINGS AND DETAILS INCLUDED IN THIS SET ARE REPRESENTATIVE OF THE DESIGN INTENT FOR ANTICIPATED FIELD CONDITIONS AND DO NOT IN ALL CASES REFLECT SPECIFIC MANUFACTURER'S DETAILS AND SPECIFICATIONS REQUIREMENTS. EACH SHEET IS PART OF A COMPLETE SET OF DOCUMENTS COMPLETED FOR THIS PROJECT AND IS TO BE USED ONLY IN CONJUNCTION WITH THE COMPLETE SET OF CONSTRUCTION DOCUMENTS. 5. CONTRACTOR SHALL REVIEW CONTRACT DOCUMENTS FOR THE PROJECT AND NOTIFY THE ARCHITECT OF ANY OBSERVED DISCREPANCIES PRIOR TO THE START OF CONSTRUCTION. 6. THE CONTRACTOR SHALL COORDINATE THE WORK OF ALL TRADES IN ACCORDANCE WITH THE SPECIFICATIONS AND MAKE ADJUSTMENTS IN LAYOUT AS REQUIRED, WITH ARCHITECT/ENGINEER APPROVAL ONLY, TO AVOID CONFLICT BETWEEN TRADES FOR PROPER EXECUTION OF THE WORK. 7, THE CONTRACTOR SHALL PROVIDE PROTECTION EQUIPMENT FOR SURROUNDING MATERIAL AND SITE DURING CONSTRUCTION. 8. THE CONTRACTOR SHALL, AT HIS OR HER EXPENSE, RESTORE TO "LIKE NEW" CONDITION ANY DAMAGE TO SURROUNDING MATERIALS DURING CONSTRUCTION. 9. CUTTING OF STEEL, WOOD, OR OTHER MAIN STRUCTURAL MEMBERS IS NOT ALLOWED WITHOUT WRITTEN APPROVAL FROM THE ARCHITECT/ENGINEER PRIOR TO CUTTING. h 0. MAINTAIN PREMISES AND PUBLIC AREAS FREE FROM ACCUMULATED WASTE AND RUBBISH CAUSED BY NORMAL CONSTRUCTION ON A DAILY BASIS, UPON COMPLETION OF WORK, REMOVE WASTE MATERIALS, RUBBISH, TOOLS, AND EQUIPMENT, AND LEAVE PROJECT AREA CLEAN AND READY FOR OCCUPANCY. 11. PROVIDE REQUIRED COORDINATION AND SUPERVISION WHERE WORK CONNECTS TO OR IS AFFECTED BY OTHER WORK. 12. WHERE WORK OF ONE TRADE WILL BE INSTALLED IN CLOSE PROXIMITY TO WORK OF OTHER TRADES OR WHERE ONE TRADE WILL INTERFERE WITH WORK OF OTHER TRADES, CONTRACTOR SHALL ASSIST IN WORKING OUT CONDITIONS TO COORDINATE INSTALLATION AND PROVIDE COORDINATION DRAWINGS IN 1 /8" = 1'-O" SCALE (MINIMUM]. 3. WHERE TWO OR MORE DETAILS, MATERIALS, OR CONDITIONS OCCUR IN APPARENT CONFLICT, THE CONTRACTOR SHALL USE THE MOST EXPENSIVE SOLUTION IN HIS BID. NOTIFY THE ARCHITECT OF ANY APPARENT DISCREPANCIES PRIOR TO COMMENCING WITH THE WORK. 4. PERMITS: THE GENERAL BUILDING PERMIT FOR THE PROJECT SHALL BE OBTAINED PRIOR TO CONSTRUCTION BY THE CONTRACTOR. HE SHALL SECURE THE PERMITS REQUIRED FROM THE APPROPRIATE AUTHORITIES HAVING JURISDICTION. 5. CONSTRUCTION COMPLETION PROCEDURES: OBTAIN CERTIFICATES OF OCCUPANCY OR USE, FROM ALL PERMITTING AGENCIES REQUIRED FOR THIS PROJECT, PRIOR TO SUBSTANTIAL COMPLETION. PRESENT ALL CERTIFICATES OF OCCUPANCY OR USE TO THE OWNER AS A CONDITION OF SUBSTANTIAL COMPLETION. 6'-2" A4 l um. STA1 R G.C. TO R0 SHOP DIES I F,A5�ICATION ,AND APPROV 2ND FLOOR PLAN - SCALE: 1/4" = 1'-0" NON -BEARING INTERIOR PARTITIONS ALL INTERIOR NON BEARING PARTITIONS SHALL BE 3 5/8" METAL STUDS 26 GA AT 24" D.C. MAX. SPACING W/ 5/8" MIN. GYPSUM DRYWALL EACH SIDE. UILDING IDE TIFICATION APPROVED NUMBERS OR ADDRESSES BE PLACED ON ALL NEW AND EXISTING BUILDINGS IN SUCH POSITION AS TO BE PLAINLY VISIBLE AND LEGIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY. SAID NUMBERS SHALL CONTRAST WITH THEIR BACKGROUND �: MIRRORS SHALL BE ANCHORED TO STUDS WHEN IN EXCESS OF 9 S.F. BATHROOM FLOORS AND BASE SHALL BE IMPERVIOUS MATERIALS PER FLORIDA BUILDING CODE, 2017 6TH EDITION. TILE FINISH SELECTED BY OWNER BATHROOMS BATHROOM FLOORS AND BASE SHALL BE IMPERVIOUS MATERIALS PER FLORIDA BUILDING CODE, 2017 6TH EDITION. TILE FINISH SELECTED BY OWNER AA20003774 T SW nALNILL AVIM POPT SAPT LUC r rL. )4V 772-800-N00 www. b](jrchiteaure,com OF FL Y �ER E � AEG L� uJ < 0 J � �o <U- u.- 0 pG J � UJ Ll_.J Jl >�0 U—j v O d DOCU AMT DATE:: PEVISI017S: rl% TOUR PROOMS SUDNT DATE 9UILDIMI DIPARTAMT COAAMTS 08232021 SMUT TITLE: FLOOR PLAN S V 4 4 5'-9" 6'-W 1 EY-0" OFFICE TREATMENT C? TREATMENT Cl? .4 C TA 1 6" 6'-4" CU A SOUND A CONTROL A n C=Q .3 LJ 4. FS OCCUPANCY CLASSIFICATION I W" TREATMENT I I OFFICE 6D N- 10'-2" Im Ol% 17'-9" FIXED SEATING ASSEMBLY AREA PLATFORM 12'-0" 1 E3'-O" DIMENSION PLAN �* LB) Architecture AA20005774 T SW MULL WnUr PORT SA PT LUG r rL, 34V 772-800-W00 wwwlbidr(hkdurc.(om < U- 0 10 an < U- 0 LL-j < < LV U-j 00 GEC 0 >- U-j F- 0 DOW/All"IT DATE:: DATE: RIVIslorls: Fl% YOUR PROORISS SMAIT DATC bUILDIM DIPARTIAMT (OMMTS 08232024 St111T TITLE: DIMENSION PLAN SHUT rlu/Ab[R: A �2 BOTTOM OF EXISTING STRUCTURE 5/8" GYPSUM WALLBOARD 3-5/8" " METAL STUD 16"oc 31 1 /2" SOUND ATTEN. BLANKET (SEMI-RIGID/NON-COMBUSTIBLE) CAULKED JOINT FINISH FLOOR TYP. WALL ASSEMBLY SCALE; 3/4" = 1'-0" 10" METAL STUDS 12" O.C. 14 GAI IGE 12" O.C. •-------------------- -- - I I I I I i I i I I I i I I NOMINAL 3/4" RED OAK WOOD FLOORMCs OVER In" CDX PLYWOOD ON NOMINAL 2"x3"PT. WOOD SLEEPERS ON PVC RESILIANT PADS OVER 6 MIL. POLYETHELENE. 2"D. RED OAK HALF ROUND CCNT. 2"xl 1/2" (ACTUAL. WOOD NAILER WITH 1/49/4" SLOTS * C. 2"O.FOR VENTING WOOD FLOOR 1 1/4"x 6 3/8" RED OAK CROWN MOULDING GONT. I"x4" WOOD NAILER WITH 1/4"A/4" SLOTS i 2"O C. FOR VENTING WOOD FLOOR 3/4" PLYWOOD SAW CORRUGATED STEEL DECK 8" STRUCTURAL STEEL STUDS (HORIZONTAL) 8" STRUCTURAL STEEL 14 GA. STUDS 12" O.C. (VERTICAL) NOMINAL 3/4" RED OAK PLANKING (VERTICAL) ON 1"x4" P.T. WOOD FURRING. O Altar Apron (Front Detgjl�, PLATFORM FLOOR RED OAK BULLNOSE WITH 1" RADIUS AND 3/4" RETURN 10" METAL STUDS 12 °' O.G. 14 GAUGE 12" O.C. ------------------ A 4 j I— i i- Alter !;tmr FLOOR MOUNTED WATER CLOSET WALL HUNG URINAL STEEL STUDS 1 /2" TILE BACKER BOARD CERAMIC TILE FINISH - REFER CLEAR TO FINISH SCHEDULE 1 1 /2" DIA. STAINLESS STEEL GRAB BARS, REFER TO FLOOR PLANS FOR LENGTH AND LOCATIONS CONCEALED MOUNTING W/2-SCREWS PER FLANGE 12 GAUGE x 3" WIDE ANCHOR PLATE IN LENGTHS TO ACCOMMODATE DIFFERENT LENGTHS OF GRAB BARS. ANCHOR PLATES SHOULD HAVE DIEFORMED AND TAPPED MOUNTING HOLES THAT MATCH CONCEALED MOUNTING PLATES OF GRAB BARS. INSTALL PER MANUFACTURER'S SPECIFICATIONS CUTOUT FOR ANCHOR PLATE - INSTALL PER MANUFACTURER'S SPECIFICATIONS 01 %Lw YAM NOTE: SINKS SHALL COMPLY WITH ADA REQUIREMENTS E� LAVATORY 4 MIRROR TOILET ACCESSORIES LAVATORY 8 MIRROR HANDICAPPED O FEM, PROD. DISPENSER PARR TOWEL 0 o DISPENSER DRINKING FOUNTAIN TOILET ACCESSORIES TYPICAL MOUNTING HEIGHTS MIRROR PLASTIC LAMINATE ON 3/4" THICK EXTERIOR GRADE CONT. SEALANT PLYWOOD AT VANITY BACKSPLASH RETURN COPE OUT HORIZ. LEG OF WHERE INDICATED STEEL ANGLE AT LAV'S J GYPSUM WALLBOARD ON MTL STUDS REFER TO FINISH SCH. FOR WALL AND FLOOR FINISHES Cr7 LA? RETURN PLASTIC LAMINATE AT SPLAYED 3/4" TH'K EXT. GRADE PLYWOD FACE PANEL FASTEN SPLAYED FACE TO METAL CLIPS W/LAG SCREWS FROM REAR SIDE PROVIDE 2'O"L. REMOVABLE ACCESS PANEL AT LAWS ATTACH W/CHROME OVAL HEAD CREWS AND CHROME INISH WASHERS 3 MOUNTING PLATES PER STEEL FRAME) SLOPE SPLAYED FACE AS FAR AS PRACTICAL TO PIPING FOR ADEQUATE CLEARANCE FOR HANDICAP. ACCESS HANDICAP LAV DETAIL m Cu TOILET TISSUE DISPENSER 0 TOILET ACCESSORIES PAPER TOWEL SOAP DISPENSER DISPENSER OVER COUNTER SINK ACCESSORIES TOILET ACCESSORIES SANITARY NAPKIN DISPOSAL/ T.P. HOLDER j- X UA (L t-- FIRE EXTINGUISHER 1/811 TH'K 6TAAINLE56 STEEL ATTACHING PLATES AT EACH STEEL FRAME O ' TH'K 5TAINLE55 :EL ATTACHING ATES AT EACH -.EL FRAME REFER TO SECTION LEFT FOR LAMINAT; PLASTIC PANEL INFORMATION s PROVIDE 2"x2"xI/4" STEEL ANGLE FRAMES WITH WELDED CONNECTIONS, BOLT TO HORIZONTAL ANCHOR PLATES REFER TO INTERIOR ELEVATIONS FOR STEEL FRAME LOCATIONS AND LOCATIONS OF REMOVABLE ACCESS PANELS LBJ Architecture AA20005774 T SW MULL AVrRUr PUT SAINT LUC r LL. )4V 772-800-N00 www1pir(hiteauruom v /-V 11 ) %.n LI— Q Q OJ �G 0 Co Q U- 0 ,.%, U-1 � � J �L J � 00 f-v O > U—) r,-. 0 DOW/AEnT DATE:: DATE: REVISIOris: 17% TOUR PROOR155 SUMIT DATE 6UILDIM WARTADIT COrAMTS 08232024 SHICT TITLE. - DETAILS SHEET f1UM6ER: AIIIIIIIIIIII 3 EXIS 41 '4 . I . 4a .4,dd 4 A NEW 24"x24" CONCRETE FOOTING 'd. WITH #5 RBR 6" O.C. EA WAY UChlropm SECTION/ELEVATION OF STEEL BEANA L I NOTE: THE INSTALLATION OF GLAZING PROTECTION DEVICES HAS BEEN CONSIDERED IN THE DESIGN OF THE SUPPORT STRUCTURE CONCRETE LINTEL 'CAST-CRETE' SEE LINTEL SCHEDULE FOR REINFORCING & FILLING, IF REQUIRED #5 STEEL RB PER PLAN CONCRETE BLOCK WALL BOTTOM OF FOOTER w Ir N FUdFvr.-lFl-T@Tlv"TTffWvj POUR SOLID 8" DEEP (MIN) AT EACH WINDOW SILL NOTE: SEE FOUNDATION PLAN FOR COLUMN LOCATIONS & REINFORCING 4 /nll mm T VWALL % WOOD FRAMING STUCCO FINISH OVER 8 X 16 C,M.0 Will I k' 4 1 No 'y 11 16 X 3"' TAPCON FILL ALL FACTORY PROVIDED HOLES THRU FRAME TO BLOCK 1 X (FRAME WIDTH) PT BUCK APPLIED TO CONCRETE FILLED MASONRY VVI POWER ACTIVATED BROAD HEAD COIL NAIL La 6" O.C. 112' DRYWALL INTE.'RIORWOOL) FRAMING 6 PANEL WOOD DOOR STUCCO FINISH OVER 8 X 16 C.M.U. CAULKING X" X 5" TAPGON (3) PER SIDE THRU FRAME TO BLOCK Architecture AA20005774 T SW rALULL MMUC PORT SAINT LUa rL. M)) 772-800-N00 wwwbi,jrhte'(tur�.(om OF FL cJ E D r"Ll LL—j < U- 9 U- 0 nz 0 < U- Ow, L 0 Cv DOUAMT DATE:: DATE: RIVIslorls: r1% TOUR WOMBS Subrw DATC NUILDIFla WARTACTIT (ONAMTS 082=24 SHUT FlUnb[P: EXISTING FRONT ELEVATIONS 1 KEY NOTES OPREVIOUS LOCATION OF EXISTING 200A PANEL; NEW FEEDERS TO BE PULLED TO NEW LOCATION OF NEW 200A PANEL. CIRCUIT THROUGH PHOTOCELL / TIMECLOCK. LIGHTING CONTROL SYSTEM LINE RISER r-a ILC APPRENTICE II RELAY PANEL line G2 LV Switch load (typical of up to 4) EXISTING 120/24OV, 10 SERVICE G2 LV Switch G2 LV Switch O CAT5 CABLE WITH RJ45 CONNECTORS 00=A EYE ITT mna N11011� n' 00 ct'[RI1710M. Fo at ft ow ir IM A. ddoMr. °dJl"h""'b and .oM or opall Mleida�alt6n Weo at 1me. UM ti* tq of 911"74-p1111W *M tee& EXTERIOR 3#3/0 & 1#213 - 2" NEW 200A 20 AA 2P NEMA 3R EXISTING METER AND MAIN FOR EX. METER ADJACENT TENANT. NOT IN SCOPE QEX. METER Q EX. RACEWAY LEGEND INTERIOR NEW EXISTING 200 AMP PANEL A EXISTING ELECTRICAL RISER DIAGRAM • • NEVINISTIMINUM LightSyncTm G2 Dataline Switch Detail E) Ow" 15 posm- 6 !. 2 od- t 0 0 BACK A ` p . 0 0611" 1�-1m 8'RRadT HOLE FOR FOR /6-M RJ-!5/OAT-5 JACK (2) 52 THREADED A. ALL EQUIPMENT TO BE BY INTELLIGENT LIGHTING CONTROLS, INC. ON -SITE SYSTEM COMMISSIONING SHALL BE REQUIRED. COMMISSIONING OF SYSTEMS VIA MODEM WITHOUT ON -SITE SUPPORT SHALL NOT BE ACCEPTED. B. ELECTRICAL CONTRACTOR TO PROVIDE CAT-5 DATA CABLE. SEE CAT-5 REQUIREMENTS SHEET & RJ45 CONNECTOR DETAIL. TEST ALL CABLE LENGTHS AND TERMINATION'S W/CAT-5 TESTER. C. ALL LOW VOLTAGE COMMUNICATION CABLE & HARDWIRE LOW VOLTAGE CONTROL WIRING TO BE INSTALLED PER NATIONAL ELECTRICAL CODE FOR CLASS-2 LOW VOLTAGE WIRING. D. CLASS-2 LOW VOLTAGE WIRING SHALL NOT BE MIXED WITH OR RUN IN LINE VOLTAGE RACEWAYS. SEPARATE LOW VOLTAGE RUNS FROM LINE VOLTAGE BY A MINIMUM DISTANCE OF 1-FOOT. E. CAT-5 DATA CABLE RUNS TO BE INSTALLED IN A DAISY CHAIN FROM ONE PANEL. OR DEVICE TO THE NEXT. NO "STAR" OR "T" CONFIGURATIONS ALLOWED WITHOUT POWER SUPPLY REPEATERS. F. ALL CLASS-2 & CAT-5 DATA CABLE RUNS TO BE PROVIDED AND INSTALLED WITH THE APPROPRIATE JACKET TYPE OR CONDUIT FOR THE INSTALLA11ON ENVIRONMENT OR CONDITIONS ON SITE. G. EACH LIGHTING RELAY PANEL REQUIRES A DEDICATED 120V. OR 277V, CIRCUIT' FOR CONTROL POWER TRANSFORMERS. H. ADDITIONAL ILC POWER OR DATA REPEATING DEVICES MAY BE REQUIRED FOR PROPER SYSTEM OPERATION, BASED ON THE ACTUAL NUMBER AND DISTANCE OF UghtSync DEVICES TO BE INSTALLED ON CAT-5 DATA LINE- CONTACT AMY LEE 0 SESCO LIGHTING 954-474-9888. COIN'TROLi NrU ELECTRICAL SPECIFICATIONS PERT 1 - GENERAL A. THE CONTRACTOR SHALL SUPPLY AND INSTALL ALL NEW ELECTRICAL WORK INDICATED. CONSTRUCTION SHALL BE IN ACCORDANCE WITH DRAWINGS AND APPLICABLE SPECIFICATIONS. IF A PROBLEM IS ENCOUNTERED IN COMPLYING WITH THIS REQUIREMENT, CONTRACTOR SHALL NOTIFY THE ARCHITECT/ENGINEER AS SOON AS POSSIBLE AFTER DISCOVERY OF THE PROBLEM AND SHALL NOT PROCEED WITH THAT PORTION OF THE WORK UNTIL ARCHITECT/ENGINEER HAS DIRECTED CORRECTIVE ACTION TO BE TAKEN, B. THE CONTRACTOR SHALL VISIT THE JOB SITE PRIOR TO BID AND FAMILIARIZE HIMSELF WITH ALL CONDITIONS AFFECTING ELECTRICAL AND COMMUNICATIONS INSTALLATION AND MAKE PROVISIONS AS TO THE COST THEREOF. C. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE LATEST EDITION OF THE NATIONAL ELECTRIC CODE (AS ADOPTED BY THE AUTHORITY HAVING JURISDICTION) AND ALL CODES AND ORDINANCES OF THE AUTHORITY HAVING JURISDICTION. THE SPECIFICATION, CODES AND STANDARDS LISTED BELOW ARE UTILIZED IN THIS PROJECT. 1. NATIONAL ELECTRICAL CODE (NFPA-70) 2. CODE FOR SAFETY TO LIFE (NFPA-101) 3. STANDARD FOR THE INSTALLATION, MAINTENANCE AND USE OF LOCAL PROTECTIVE SIGNALING SYSTEMS (NFPA-72) 4. UNDERWRITERS' LABORATORIES (UL) 5. NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION (NEMA) 6. AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI) 7. FEDERAL SPECIFICATION (FED. SPEC.) 8. INSULATED POWER CABLE ENGINEERS ASSOCIATION (IPCEA) 9. FLORIDA BUILDING CODE. FBC 2017 EDITION 10. INSTITUTE OF ELECTRICAL AND ELECTRONIC ENGINEERS (IEEE) 11, CITY OF PORT SAINT LUCIE BUILDING CODE. (AMENDMENTS TO FLORIDA BUILDING CODE FBC 2017) 12. ADDITIONALLY, DESIGNS, WORK PRACTICES AND CONDITIONS MUST CONFORM WITH THE OCCUPATIONAL SAFETY AND HEALTH ACT OF 1970 (OSHA) D. DO NOT SCALE THE ELECTRICAL DRAWINGS. REFER TO ARCHITECTURAL PLANS AND ELEVATIONS FOR EXACT LOCATION OF ALL EQUIPMENT. CONFIRM NTH OWNER'S REPRESENTATIVE. E. IT IS NOT THE INTENT OF THESE PLANS TO SHOW EVERY MINOR DETAIL OF CONSTRUCTION. THE CONTRACTOR IS EXPECTED TO FURNISH AND INSTALL ALL ITEMS FOR A COMPLETE ELECTRICAL SYSTEM AND PROVIDE ALL REQUIREMENTS NECESSARY FOR EQUIPMENT TO BE PLACED IN PROPER WORKING ORDER. F. CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORKMANSHIP FREE FROM DEFECTS FROM A PERIOD OF NOT LESS THAN ONE YEAR FROM DATE OF ACCEPTANCE. G. CORRECTION OF ANY DEFECTS SHALL BE COMPLETED WITHOUT ADDITIONAL CHARGE AND SHALL INCLUDE REPLACEMENT OR REPAIR OF ANY OTHER PHASE OF THE INSTALLATION WHICH MAY HAVE BEEN DAMAGED THERE BY. H. ALL REQUIRED INSURANCE SHALL BE PROVIDED FOR PROTECTION AGAINST PUBLIC LIABILITY AND PROPERTY DAMAGE FOR THE DURATION OF THE WORK. CONTRACTOR SHALL PAY FOR ALL PERMITS, FEES, INSPECTIONS AND TESTING. CONTRACTOR TO OBTAIN PERMIT AND APPROVED SUBMITTALS PRIOR TO BEGINNING WORK OR ORDERING EQUIPMENT. THE TERM "PROVIDE" USED IN THE CONSTRUCTION DOCUMENTS AND SPECIFICATIONS SHALL MEAN THAT THE CONTRACTOR IS TO FURNISH, INSTALL AND CONNECT COMPLETE. PART 2 - PRODUCTS A. MINIMUM WIRE SIZE SHALL BE #12 A.W.G. (EXCEPT AS NOTED OTHERWISE FOR CONTROL WIRING). ALL CONDUCTORS SHALL BE 98% CONDUCTIVITY, COPPER WITH "THHN-THWN" INSULATION UNLESS OTHERWISE NOTED. B. ELECTRICAL METALLIC TUBING (EMT) SHALL BE OF BEST QUALITY STEEL, SMOOTH INSIDE AND OUT AND SHALL BE HOT -DIPPED GALVANIZED. C. OUTLET BOXES SHALL BE PRESSED STEEL IN DRY LOCATIONS, CAST ALLOY WITH THREADED HUBS L IN WET OR DAMP LOCATIONS AND SPECIAL ENCLOSURES FOR OTHER CLASSIFIED AREAS. D. RIGID NONMETAUC CONDUIT SHALL BE SCHEDULE 40 PVC. 6. ALL MATERIALS SHALL BE NEW AND BEAR UNDERWRITERS' LABELS WHERE APPLICABLE. F. PANELBOARDS: 1. CURRENT CARRYING BUSES SHALL BE COPPER. GROUND BUS BARS SHALL BE COPPER. 2. ALL CIRCUIT BREAKERS SHALL BE BOLT ON. PLUG-IN BREAKERS ARE NOT ACCEPTABLE. 3. CIRCUIT BREAKERS USED AS SWITCHES IN FLUORESCENT OR HID LIGHTING CIRCUITS SHALL BE LISTED AND MARKED "SWD" 4. ALL CIRCUIT BREAKERS FEEDING MECHANICAL EQUIPMENT SHALL BE HACR TYPE. 5, A.I.C. RATINGS SHALL BE AS INDICATED ON PANELBOARD SCHEDULES. 6. ALL PANELBOARDS SHALL BE FURNISHED WITH PLASTIC LAMINATE NAMEPLATES WITH 1/4" ENGRAVED LETTERING FOR PANEL IDENTIFICATION. 7. ALL PANELBOARDS SHALL BE PROVIDED WITH TYPE -WRITTEN DIRECTORY OF BRANCH CIRCUIT DESIGNATIONS. G. DISCONNECT SWITCHES SHALL BE H.P. RATED, HEAVY DUTY, QUICK -MAKE, QUICK -BREAK. ENCLOSURES SHALL BE NEMA-1 FOR INDOOR LOCATIONS, NEMA 3R FOR OUTDOOR LOCATTONSOR AS OTHERWISE NOTED. H. MOTOR STARTERS SHAD_ BE MANUAL OR MAGNETIC AS INDICATED ON THE ELECTRICAL DRAWINGS, WITH OVERLOAD RELAYS IN EACH PHASE. WIRING DEVICES (GENERAL PURPOSE RECEPTACLES AND WALL SWITCHES) COLOR SHALL BE COORDINATED WITH CLIENT. PART 3 - EXECUTION A. COLOR CODING OF CONDUCTORS SHALL BE AS FOLLOWS: 1. 208/120 VOLTS, 3 PHASE, 4-WIRE SYSTEM: UNGROUNDED CONDUCTORS: 1 BLACK, 1 RED AND 1 BLUE. GROUNDED (NEUTRAL) CONDUCTOR; WHITE. GROUNDING CONDUCTORS SHALL BE GREEN. 2. 480/277 VOLT, 3-PHASE, 4-WIRE SYSTEM: UNGROUNDED CONDUCTORS: 1 BROWN, 1 YELLOW, AND 1 PURPLE. GROUNDED (NEUTRAL) CONDUCTORS; GREY. GROUNDING CONDUCTORS SHALL BE GREEN. 3. BRANCH CIRCUIT WIRING (#6 AND SMALLER) SHALL BE COLOR CODED BY CONTINUOUS INSULATION COLOR AND FEEDERS AND SERVICES (#4 AND LARGER) SHALL BE CODED AT ALL JUNCTION OR PULL POINTS (EXCEPT LB'S OR LBD'S) USING COLOR MARKERS OR PLASTIC TAPE MANUFACTURED I FOR THE PURPOSE. B. WIRING METHODS 1. ALL CONDUCTORS SHALL BE INSTALLED IN ELECTRICAL METALLIC TUBING (EMT) UNLESS OTHERWISE NOTED, SPECIFIED OR AS SPECIFICALLY PROHIBITED BY THE AUTHORITY HAVING JURISDICTION. ALL FITTINGS AND COUPLINGS FOR EMT CONDUIT SHALL BE ALL STEEL RAIN TIGHT COMPRESSION TYPE OR ALL STEEL CONCRETE TIGHT SET SCREW TYPE. 2. SCHEDULE 40 PVC CONDUIT, WITH FITTINGS AND COUPUNGS APPROPRIATE FOR THE USE, SHALL BE INSTALLED UNDERGROUND OR BELOW SLABS ON GRADE, 3. TYPE MC CABLE WITH ALUMINUM ARMOR AND INTERNAL GROUND IS ACCEPTABLE FOR USE AS GENERAL BRANCH CIRCUIT WIRING FOR CIRCUITS 20 AMPERES OR LESS AND CONCEALED IN WALLS OR ABOVE SUSPENDED CEILING AND AS APPROVED BY THE AUTHORITY HAVING JURISDICTION. C. ELECTRICAL SYSTEM SHALL BE COMPLETE AND EFFECTIVELY GROUNDED AS REQUIRED BY THE LATEST EDITION OF THE N.E.C. AND LOCAL CODES. D. ALL WORK SHALL BE PERFORMED BY A LICENSED ELECTRICAL CONTRACTOR IN A FIRST CLASS WORKMANLIKE MANNER. THE COMPLETED SYSTEM SHALL BE FULLY OPERATIVE AND ACCEPTED BY ENGINEER/ARCHITECT. E. ALL WORK SHALL BE COORDINATED WITH OTHER TRADES TO AVOID INTERFERENCE WITH THE PROGRESS OF CONSTRUCTION. F. THE ELECTRICAL INSTALLATION SHALL MEET ALL STANDARD REQUIREMENTS OF POWER AND TELEPHONE COMPANIES, AND SHALL BE FULLY COORDINATED WITH THEM PRIOR TO COMMENCEMENT OF WORK. G. PROVIDE AND INSTALL CONDUIT, CONDUCTORS, PULL WIRES, BOXES, COVER PLATES, AND WIRING DEVICES, FOR ALL OUTLETS AS INDICATED. H. MATERIALS, PRODUCTS, AND EQUIPMENT, INCLUDING ALL COMPONENTS THEREOF, SHALL BE NEW AND SUCH AS APPEAR ON THE UL LIST OF APPROVED ITEMS AND SHALL MEET OR EXCEED THE REQUIREMENTS OF NEC, NEMA, AND IECE. CONTRACTOR SHALL SUBMIT AT LEAST FIVE (5) SETS OF SHOP DRAWINGS OR CUT SHEETS OF LIGHTING FIXTURES, SWITCHES, AND OTHER ELECTRICAL ITEMS FOR APPROVAL BY ENGINEER/ARCHITECT. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CUTTING AND PATCHING REQUIRED OF HIS WORK, K. ALL LAY -IN LIGHTING FIXTURES SHALL BE SECURED TO THE SUSPENDED CEILING GRID AT EACH CORNER. L. CONTRACTOR SHALL COORDINATE WITH MECHANICAL DRAWINGS AND PROVIDE ALL NECESSARY CONTROL WIRING. M. ALL ELECTRICAL POWER WIRING FOR THE HVAC SYSTEM INCLUDING WIRING THRU LINE VOLTAGE CONTROL DEVICES SHALL BE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR. N. THE CONTRACTOR SHALL CONFIRM WITH THE ELECTRICAL UTILITY COMPANY ANY AND ALL REQUIREMENTS SUCH AS: METERING EQUIPMENT REQUIREMENTS AND METERING EQUIPMENT LOCATION, TRANSFORMER SIZE AND LOCATION OR SERVICE POINT, CONDUIT ENTRY AND LUG SIZE RESTRICTIONS. THE CONTRACTOR SHALL SCHEDULE ALL REQUIRED DOWN TIME FOR THE OWNERS CONFIRMATION. ANY CONFLICTS AND DESCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER BEFORE 0. PROCEEDING WITH ANY WORK. PER NEC 210.8(B)(2) ALL 15- AND 20-AMPERE, 125-VOLT RECEPTACLES IN NONDWELUNG-TYPE KITCHENS TO BE GFCI PROTECTED. BRANCH CIRCUIT CONDUCTORS SHALL BE SIZED FOR A MAXIMUM VOLTS DROP OF 3% DESIGN LOAD. FBC 2017 FBC ENERGY CONSERVATION SECTION 405.7.3. Q. FEEDER CONDUCTORS SHALL BE SIZED FOR A MAXIMUM OF 2% VOLTAGE DROP PER 405.7.3. SCHEDULE OF BRANCH CIRCUIT PANEL "A" MAIN: 200 AMP MAIN LUG ONLY VOLTAGE: 120/240V, 10, 3 WIRE SPEC: SQUARE D LOAD CENTER OR EQUAL K40UNTING: FLUSH AIC SYMM: 22.000 DESCRIPTION WIRE GND. COND. TRIP CKT. A PHASE KVA C PHASE KVA CKT. TRIP COND. GND. WIRE DESCRIPTION RECEPTACLES #12 #12 1 2 20 1 0.8 0.8 2 20 1 2 #12 #12 INTERIOR LIGHTING RECEPTACLES #12 #12 1 2 20 3 0.8 1 0.8 4 20 1 2 #12 #12 EXTERIOR LIGHTING RECEPTACLES RECEPTACLES #12 #12 #12 #12 1 2 1 2" 20 20 5 7 1.0 0.8 0.6 1 - 6 8 20 20 1 2 - #12 - #12 - EXTERIOR RECEPTACLE SPARE RECEPTACLES #12 #12 1 2 20 9 1 0.6 1 3.3 101 4 2 3/4" 1 #10 WATER HEATER RECEPTACLES #12 #12 1 2 20 11 0.6 3.3 12 RECEPTACLES #12 #12 1 2 20 13 0.6-1 3.3 14 4 2 3 4 1#10 2#6 AC-1a DRINKING FOUNTAIN #12 #12 1 2 20 15 0.6 3.3 16 RECEPTACLES RECEPTACLES RECEPTACLES RECEPTACLES SPARE #12 #12 #12 #12 - #12 #12 #12 #12 - 1 2 1 2 1 2 1 2 - 20 20 20 20 20 17 19 21 23 25 0.6 1 0.8 1 0,6 1 0.8 - 2.8 0.6 0.a 0.6 1 0.8 18 20 22 24 26 20 20 20 20 3 2 1 2 1 2 1 2 1 2 3/4" #12 #12 #12 #12 1 #10 #12 #12 #12 #12 INTERIOR LIGHTING INTERIOR LIGHTING INTERIOR LIGHTING INTERIOR LIGHTING AC-2 FUTURE MINI -SPLIT SPARE - - - 20 27 - 2.8 28 SPARE - - - 20 29 - 2.8 30 307 2 3/4" 1#10 _ AC-3 FUTURE MINI -SPLIT SPARE - - - 20 31 - 2.8 32 SPARE - - - 20 33 - 6.5 34 6 - ,-2 3 4 1 #10 2#6 AC-1 b SPARE - - - 20 35 - 6.5 36 SPARE - - - 20 37 - - 38 20 - - - SPARE SPARE - - - 20 39 - - 40 20 - - - SPARE SPARE - - - 20 41 - - 42 20 - - - SPARE 20.5 19.3 KVA PER PHASE 170.8 160.8 1 AMPS PER PHASE 39.8 TOTAL KVA EVANGELICAL UNION OF FISHERMAN CHURCH LIGHTING FIXTURE SCHEDULE TYPE MANUFACTURER CATALOG NUMBER DESCRIPTION LAMPS DIMMING VOLTS - MOUNTING ---- REMARKS Qty Type Total Wattage A TRULYGREEN SOLUTIONS CHB-SE-97W-40K-U-D-B-HM CRCLUAR LED HIGHBAY INCL LED 9&6 0-10V UNV PENDANT 1,2 AEM TRULYGREEN SOLUTIONS CH8-SE-97W40K-U-D-B-EM-HM CIRCLUAR LED HIGHBAYWITH EM INCL LED 96.6 0-10V UNV PENDANT 1,2 B TRULYGREEN SOLUTIONS CHB-SE-67W-40K-U-D-B-HM CIRCLUAR LED HIGHBAY INCL LED 69.1 0-10V UNV PENDANT 1,2 BEM TRULYGREEN SOLUTIONS CHB SE-67W 40K -UD BEMHM --- CIRCLUAR LED HIGHBAYWETH EM INCL LED 69.1 0-10V UNV PENDANT 1,2 C TRULYGREEN SOLUTIONS EA-2240-35-tTD-8822-SK 2X2 LED FLAT PANEL WITH SURFACE MOUNT KIT INCL LED 40 0-10V UNV SURFACE 1 CEM TRULYGREEN SOLUTIONS EA-22-40-35-U-D-EM-8822SK 2X2 LED FLAT PANEL WITH SURFACE MOUNT KIT & EM INCL LED 40 0-10V UNV SURFACE 1 D TRULYGREEN SOLUTIONS FLU-L C-U-D COLOR AND WATTAGE SELECTABLE G' LED DOWNLIGHT, SET AT "H" INCL LED 19 0-10V UNV RECESSED 1 DEM TRULYGREEN SOLUTIONS FL-6-L-C-U-D-ELLS10CDF COLOR AND WATTAGE SELECTABLE 6" LED DOWNLIGHT WITH EM INCL LED 19 0-10V UNV RECESSED 1 E TRULYGREEN SOLUTIONS FL-6-L-C-U-D-ELIS10CDF COLOR AND WATTAGE SELECTABLE 6" LED DOWNLIGHT, SET AT"M" INCL LED 13 0-10V UNV RECESSED 1 F BEGHELLI MEZ-LED-ACEM-DB-120277 AC&EML.EDWALLPACK NVCL LED 13 0-10V UNV WALL 1 GEM H.E. WILLIAMS WPCS-L441840-EW6W-BZ CUTOFF WALL PACK WITH EM INCL LED 42 0-10V UNV WALL 1 EX BEGHELLI PX-RSA EXIT WITH EM INCL LED 3 N/A UNV SURFACE 1 --` -LED LIGHTING SCHEDULE NOTES: - ---- 1. PROVIDE SUBMITTALS FOR ARCHITECT/ENGINEER REVIEW PRIOR TO ORDERING. NO SUBSTITUTIONS At -LOWED. - 2. PROVIDE 3/4" RGC STEM TO ACHIEVE 18'AFF MOUNTING HEIGHT - - SCALE: 1/4" = V-0" On A-8 a FUTURE ME ,'ZANINE AA20005774 W SW nALKLL AKU POPT SA PT LUC � I �4V 772-800-N00 WWW.Ib]ar(hkdurP,(om L� Q ).i_ U_ 00 LgL U_ 0 •� u� LV LL_J � �G °® 0 U U-1 O nc a. DOV\Uff DATE: DATC: PrVISIOfns: 1 6UIU)IfIG DCPARTAMT (OSAMTS 10-29-21 17, SHEET TIRO: ELECTRICAL PLAN SMCCT nts/'A61R. Eml WALL LEGEND UNIT ADDRESS 78-1 PiR1M,4- VfSTA BLVD OCGUPANG`� CL ASS IF f G,4T f ON: CROUP S BUSINESS TABLE 1006.2.1 SPA[FS WI-M ONE OR EXIT ACCESS DOORWAY OCCUPANCY MAXIMUM OCCUPANT LOAD OF SPACE MAXIMUM COMMON PATH OF EGRES'z TRAVEL DISTANCE (feet) Without Sprinkler System (feet) With Sprinkler Sy5teM (feet) Occupant Load OLE30 OL>30 A,t E, M 49 9 49 100 75 100a 49 -_ 75 100a t,-1, H-2. H-3 3 Ir 25b li 4. tl-5 10 1 F' I F' 75�' I-1. 1-2.d1-4 5=, 1 3 10 NP R-1 10 R-2 49 R-3t 49 125' R 4e 20 75 75 125= 5f 29 100 75 100a U 49 100 75 75c' r—Cf. i Lnnr — 7C9.4 O rvs.`-. TOTAL FLU ING ' IXTURE5 REP.: BUSINESS OC!-UPANCY SPACES REQUIRE: I WG PER 25 1 LAVATORY PER 40 I DRINKING FOIAITAN PER 100 MALE/FEMALE 1 SERVICE 81NK MINIT`RJM LIFE SAFETY PLAN_ SCALE: 1/4" = I'-0" APPLICA5LE GODS: 2020 ITH EDITION OF FLORIDA BUILDING CODE 2020 ITH EDITION OF FLORIDA MECHANICAL CODE 2020 "ITH EDITION OF FLORIDA PLUMBING CODE 2020 ITH EDITION OF FLORIDA ELECTRICAL CODE 2020 ITH EDITION OF FLORIDA ENERGY CONSERVATION CODE 2020 -TTH EDITION OF FLORIDA FIRE PREVENTION CODE r----------------- -------- I 1 LEVEL 3 ALTEiR,4TION MORE THEN 50ro OF CROSS SQUARE FOOTAGE AFFECTED 5�' RENOV,4TION SGALE: 3/16" = 1'-0" OCCPANVY ::�,S �IGAfiIOh:dE51CNE� EO<55 COWONENE75: I `5RO55 saUARe Focrac-r cAacs: GROUP A-3- A55EM5L� OCCUPANCY W/ GROUF B TENANT T OF �,ON5 R�Co, - ION TYPE Ilia' UNPROTECTED E LINSPRINKLE'RED FOR UNSPRINKLERED BUILDING MAX. TRAVEL D15TANCE ALLOWED: 200' COMMON PATH OF TRAVEL: 100, EXIT AND MEANS OF EGRESS WIDTH DOORS 02" PER PERSON SERVED - 32" MIN CLEAR WIDTH PER TABLE 10202 CORRIDOR OCCUPANT LOAD LESS THEN 50 : 36" MIN. WIDTH 2 ;STORY BU11-DING : FIRST FLOOR; 4,200.5Q. FT SECOND FLOOR : 840 SQFT TOTAL: 5,040 SQ FT OCCUPANT L0A '_ FIXED SEATING ASSEMBLY: 64 PPL. ASSEMBLY: 51 PPL. OFFICE: I PPL. STORAGE: 3 PPL TOTAL: PROVIDE PANIC HARDWARE -------------- �c TOTAL OCCUFANCY: FIXED SEATING ASSEMBLY: r64 PPL. ASSEMBLY: 57 PPL OFFICE: 1 PPL. STORAGE: 3 PPL. TOTAL: 125 PPL. [� EXISTING WALLS TO REMAIN NEW INTERIOR FRAMING CBS WALL INFILL 2 HOUR RATED WALL UI.- 905 UNIT ADDfiRESS i89 PRIMA VISTA BLUD 903.2.1.3 C3ROUf= A-3. AN AUTOMATIC SPRINKLER SYSTEM SHALL BE PROVIDED FOR GROUP A-3 OCCUPANCIES WHERE ONE OF THE FOLLOWING CONDITIONS EXISTS: 1. THE FIRE AREA EXCEEDS 12,000 SQUARE FEET (1115 1" 12 ). 2. THE FIRE AREA HAS AN OCCUPANT LOAD OF 300 OR MORE. 3, THE FIRE AREA IS LOCATED ON A FLOOR OTHER THAN THE LEVEL OF EXIT DISCHARGE - NO CONDITIONS EXISTS FOR THIS APPLICATION a ■ 11 RISK CATEGORY I I ULTIMATE DESIGN WIND SPEED 170 2) EXPOSURE G SURFACE ROUGHNE-SS G 3) COMPONENTS & CLADDING (WORSE CASE) NOiR5E ROOF +1 &.3 _5258 GASE WALLS +503 _55.0 TOTAL FLW51NO F1XTJR10!5 REO SMALL ASSEMBLY USE SPACES REQUIRE: I WC PER 125 MALE-65 FEM: a-E I LAVATORY PER 200 MAL r FEMALE I DRINKING FOUNTAIN PER YrnO MALE/FEMALE 1 SERVICE SINK MMIMUMAee-mbly Occupancy Recommend®: Potty Parlty In A Ratio Of 3 To 2. Ferrate VS. Male ASSEMBLY: 164 PERSONS: z,-' MALE 82 FEMALE TOTAL FIXTURES REQUIRED:, MALE I WC I LAV FEMALE 2 = I LAV I ' -q=. i SERVICE SINK TOTAL FIXTURES PROVIDED_ t;' LE 2 0C 2 LAV FEMALE 2 U1C 2 LAV 2 D.F. I SERVICE SINK LB) Architecture AAMOM774 W SW HALULL MMUC POPT SAPT LU(Ic rL. )4V 772-800-5700 www.lbjarchitc(turc.com OF FL 0� Idum=0248 E D PARl' v U-) U- p p Q > � 0 4 0 < J _Q�_� J � U�� Lai 00 DOCU/1EI7T DATE PIVISIOrls: r1% TOl1R PROGRESS SWIT DATC DWLDIM DEPARTIMT (O AMtTS 06232021 COUNTY M, S1`1[[T TITLE: LIFE SAFETY PLAN SHIFT M('1 M 1�--\L'S-1 A., :Ak, W""d1v Architecture PACKAGE A/C EOUIP. SCHEDULE A/C UNIT TAG AC-10 5.0 TON AC -lb 3.0 TON MANUFACTURER CARRIER CARRIER MODEL 50VL-A60 5OVL-C36 TOTAL SENSIBLE CAP. MBH. 44.5 25.6 TOTAL COOUNG CAP. MBH. 57.9 34.8 ENT. AIR TEMP D.B./W.B. "F 80'/67' 80-/67- LEAV. AIR TEMP D.B./W.B. % - - SUPPLY AIR CFM 2000 1150 OUTSIDE AIR CFM 200 - 200 120 - 120 VOLTAGE 208/10/60 240/10/60 MCA/MOCP 35.5/40.0 34/35 SEER/EER 14,2/_ 14.0/- OPERATING WEIGHT LBS. 487 349 DIMENSIONS L x W x H (IN.) 48X43X54 49X33X52 NOTES - 1-17 REF./LBS. R-41 OA/- R-41 OA/- NOMINAL TONNAGE/STAGES 5,0/2 3/1 NO. OF COMPRESSORS 1 1 COMP. R.LA. EACH 16.0 10.4 NO. OF OUTDOOR FANS 1 1 FAN FLA. EACH 1.2 1.0 INDOOR FAN TYPE FC FC FAN E.S.P. (IN. W.G.) 1- 0,5" FAN H.P./B.H.P. 1.0 BHP 0.75 BHP FAN F.LA. 7.6 6.0 COL ROWS/FPI - -- HEATER TYPE ELECTRIC ELECTRIC HEATER K.W. O RATED VOLTAGE 5 O 240V/10 5 O 24OV/10 NO. OF STEPS j 1 FILTER TYPE/EFF. �97�L 1. UNITS SHALL BE "ARI" RATED. APPROVED EQUIVALENT: AAON, c r►wnV u_,v,•V • An V 1. THE CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, AND EQUIPMENT NECESSARY FOR THE INSTALLATION OF A COMPLETE SYSTEM IN ACCORDANCE WITH THESE DRAWINGS, THE FLORIDA BUILDING CODE 2017 AND ALL OTHER APPLICABLE STATE, COUNTY AND LOCAL ORDINANCES AND THE LATEST ADDITION OF THE FOLLOWING PUBLICATIONS; SMACNA-85, 92, 95; ASHRAE 15-01, 34-01, 62-04, NFPA 70-02, 72-02, 9OA-02, 90B-02, 91-99, 96-01; ANSI Z10.1-98, Z10.3-98, Z21.8-94, Z21.83-98. 2. THE CONTRACTOR SHALL PAY ALL COSTS OF PERMIT, INSPECTIONS AND ALL OTHER COSTS INCIDENTAL TO THE COMPLETION AND TESTING OF THIS WORK. 3. THE CONTRACTOR SHALL VISIT THE SITE AND COORDINATE WORK WITH OTHER TRADES. 4. THE CONTRACTOR SHALL SUPPLY THE ARCHITECT WITH "AS -BUILT' DRAWINGS. 5. CONTRACTOR SHALL SUBMIT, FOR APPROVAL FIVE [51 COPIES OF MANUFACTURER'S DRAWINGS FOR EACH PIECE OF EQUIPMENT AND CONTROLS INCLUDED IN CONTRACT, 6. ALL MATERIAL SHAD- BE NEW OF U.S. MANUFACTURER OF GOOD QUALITY. ALL WORK SHALL BE PERFORMED AT INDUSTRY STANDARD QUALITY LEVEL BY CERTIFIED PROFESSIONALS. ALL EQUIPMENT SHALL BE UL OR ETL LISTED. ALL INSTALLATIONS SHALL COMPLY WITH FMC 2017. CH. 3, GENERAL REGULATIONS. BUILDINGS LOCATED WITHIN 3,000 FT FROM THE OCEAN SHALL UTILIZE NON-FERROUS MATERIALS FOR ALL OUTDOOR EXPOSED SUPPORTS, STANDS, FASTENERS, ETC. 7. DUCTWORK: & ALL AIR CONDITIONING DUCT WORK SHALL BE OF 1-1/2" (R-6) HEAVY DUTY FOIL REINFORCED FIBERGLASS WITH MANUFACTURER'S LOGO PRINTED ON VAPOR BARRIER & ALL FLEX DUCT SHALL BE RATED CLASS 1, UL-181 LISTED WITH METALLIZED INNER AND OUTER FOIL UNERS, MIN. R-6 WITH A MAX. TOTAL LENGTH NOT TO EXCEED 15 FT. FLEX113LE DUCTWORK ELBOW SUPPORTS AT EACH DIFFUSER, GRILLE, AND REGISTER EQUAL TO "FLEXFLOW ELBOW" AS MANUFACTURED BY 'THERMAFLEX'. C. ALL EXHAUST DUCTS AND OUTSIDE AIR DUCTS SHALL BE GALVANIZED SHEET METAL WITH SEALED SEAMS AND JOINTS. ALL OUTSIDE AIR DUCT SHALL BE INSULATED WITH EXTERNAL BLANKET INSULATION R-6 MIN. ALL METAL EXHAUST, MAKE-UP OR OTHERWISE DUCTS INSTALLED IN LOCATIONS WHERE DEWPOINT CONDITIONS CAN OCCUR INSIDE THE DUCT SHALL BE EXTERNALLY INSULATED WITH R-6 MIN. THE CONTRACTOR SHALL PROVIDE ALL SHEETMETAL DUCTWORK, HANGERS, AUX. SUPPORT STEEL, ETC. ALL METAL DUCTS SHALL BE FABRICATED IN ACCORDANCE NTH LATEST EDITION OF S.M.A.C.N.A. AMAL SMAC14A DUCT PRESSURE CLASSES BASED ON OPERATING PRESSURE ARE: 1/2-, 1", 2-, 3-, 4'. 6", AIND 10". EACH DUCT SYSTEM SHALL BE CONSTRUCTED FOR THE SPECIFIC DUCT PRESSURE CLASS SHOWN ON PLANS. WHERE NO PRESSURE CLASS IS SPECIFIED FOR CONSTANT VOLUME SYSTEMS, 1" W.G. PRESSURE CLASS IS THE BASIS OF COMPUANCE WITH THE SMACNA STANDARDS REGARDLESS OF VELOCITY. WHERE NO PRESSURE CLASS IS SPECIFIED FOR VARIABLE VOLUME SYSTEMS, 2" W.G. PRESSURE CLASS IS THE BASIS OF COMPLIANCE WITH THE SMACNA STANDARDS FOR DUCTWORK UPSTREAM OF VAV BOXES. ALL DUCTWORK SHALL BE SEALED TO SMACNA "HVAC DUCT CONSTRUCTION STANDARDS' FOR ITS PRESSURE CLASS SEALING METHODS. 9. OUTSIDE AIR INTAKES SHALL BE SCREENED WITH A CORROSION RESISTANT MATERIAL NOT LARGER THAN 1/2" MESH. O/A INTAKES SHALL NOT BE TAKEN FROM A LOCATION CLOSER THAN 10 FT. FROM ANY CHIMNEY, VENT OUTLET OR SANITARY SEWER VENT OUTLET, UNLESS SUCH VENT IS NOT LESS THAN 24 INCHES ABOVE THE OUTSIDE AIR VENT. OUTSIDE AIR INTAKE VENTS LOCATED ON ROOFS WILL BE PROPERLY MARKED WITH A UNIVERSAL MARKIING "INTAKE', PERMANENTLY ATTACHED PER FMC 2017, SEC. 401.5 10. DUCT SIZES SHOWN ARE INSIDE DIMENSIONS. 11. ALL AJR DEVICES (DIFFUSERS, REGISTERS AND GRILLES) SHALL BE ALL ALUMINUM CONSTRUCTION WITH EXPOSED SURFACE OFF WHITE BAKED ENAMEL FINISH OR AS SPECIFIED BY ARCHITECT. DEVICES SHALL BE AS SPECIFIED OR EQUAL TO TITUS OR METALAZRE. PROVIDE OPPOSED BLADE DAMPERS AT ALL DIFFUSERS AND REGISTERS AS INDICATED ON PLANS. PROVIDE BALANCING DAMPERS FOR ALL SUPPLY AND RETURN DIFFUSERS AND REGISTERS TO ERASURE COMPLAINCE WITH FMC 2017, PAR. 601.5 AND PAR. 603.18 FOR BALANCED AIR FLOW. 12. TEMPERATURE CONTROLS/THERMOSTAT- A. SHALL BE COMBINATION COOUNG/HEATING, WITH SYSTEM "COOL -AUTO - HEAT --OFF' AND FAN "ON -AUTO" SELECTOR SWITCHES. PROVIDE PROGRAMMABLE TYPE AS RECOMMENDED BY MANUFACTURER, HONEYWELL OR EQUAL PROVIDE TAMPER PROOF COVERS. 13. THERMOSTAT LOCATION SHALL BE APPROVED BY OWNER AND ENGINEER BEFORE INSTALLATION. INSTALL THERMOSTAT 48' TO 54" A.F.F. PER A.D.A REQUIREMENTS WHERE APPLICABLE. MECHANICAL CONTRACTOR SHALL COORDINATE WITH ELECTRICAL CONTRACTOR ALL REQUIREMENTS FOR JUNCTION BOXES, CONDUITS, CONTROL. WIRING, POWER, ETC. AND DEFINE RESPONSIBIUTIES AND SCOPE OF WORK FOR EACH TRADE PRIOR TO ANY PURCHASING OR INSTALLATION. WHENEVER THERE ARE MORE THAN ONE SENSOR OR THERMOSTAT, SIDE BY SIDE, THEY SHALL BE GANGED TOGETHER WITHIN THE SAME COVER PLATE WHEREVER POSSIBLE. CONTRACTOR SHALL COORDINATE THIS ISSUE WITH ARCHITECT/OWNER PRIOR TO INSTALLATION AND SHALL BRING ANY DISCREPANCY TO THE ENGINEER'S ATTENTION. 14. REFRIGERANT UNES SHALL BE COPPER, TYPE -L" HARD DRAWN WITH WROUGHT COPPER BRAZING -JOINT TYPE FITTINGS, USE BRAZING MATERIALS FOR HIGH PRESSURE PIPING PER AWS A5.8: BCuP SERIES COPPER -PHOSPHORUS ALLOY OR BAg1 SILVER ALLOY. REFRIGERANT UNES SHALL BE SIZED PER MANUFACTURER'S RECOMMENDATIONS. SOFT COPPER TYPE 'M' SHALL BE ALLOWED FOR RISER PIPING INSIDE CHASE TO OMIT NUMBER OF JOINTS. COORDINATE WITH ENGINEER FOR PRIOR APPROVAL ALL EXPOSED INSULATION SHALL BE PROTECTED WITH UV RESISTANT PAINT OR ALUMIN. SHIELD. 15. ARMAFLEX INSULATION SHALL BE USED FOR SUCTION UNES (1/2- FOR ABOVE 40- F AND 1- FOR BELOW 40- F) PER FLORIDA ENERGY CODE TABLE 4-11 FOR PIPING INSULATION. FILTER/DRYER AND SIGHT GLASS SHALL BE PROVIDED AT UQUID UNES. O SIDE AIR CALCULATIONS (PER TABLE 6-1, ASHRAE 62.1-2010) AREA SERVED AREA SQ.FTNET ABLL AREA R RATE T(R) CFIM/FT"2 TOTAL NO, OF AIR RATE (RP) OUTDOOR CFM/PERSON DEFAULT DEFAULT VALUES TOTAL. NO. OF PEOPLE FROM DEFAULT VALUES COMBINED OUTDOOR AIR RATE 0 TOTAL /O/A TOTAL PROVIDED NOTES OCC. DENS. P/ I000FT"2 FL AR. CFM/PERSON AC-la ASSEMBLY 820 0.06 25 5 - - 49.2+125 174.2 175 SEE NOTES AC -lb LOBBY/ASSEMBLY 155206 10. 25 5 - - 93.12+125 218.12 220 SEE NOTES TOTAL _ _ 392.3 395.0 NOTES- 1. CALCULATIONS ARE BASED ON ESTIMATED MAX. OCCUPANCY RATES PER ARCHITECTURAL PLANS AND ASHRAE 62.1. VENTILATION RATES PER ASHRAE 62.1 2. FOR OFFICE AND OTHER SIMILAR AREAS CALCULATIONS ARE BASED ON CONTINUOUS OCCUPANCY FAN SCHEDULE MEMODATA FAN DATA M011umn DATA DATA TAG SERVICE AREA MANUF.(i) MODEL CONFIG. CFM ESP ("WG) SONES HP RPM DRIVE VOLTAGEIMENSION L"xWxH' OPENING L"xW" CONTROL ACCESSORIES EF-1-6 BATHROOMS GREENHECK SP-AP0511W CEILING 80 .2 0.7 10.5 WATT 831 DIRECT 120/1/6014X12X8 • LIGHT INTERLOCK 1-7 (') APPROVED EQUAL MANUFACTURER: COOK, TWIN -CITY, ACME, PENN ACCESSORIES NOTES: 1. PROVIDE GRILLE COLOR PER ARCH. SPECS S;EdEBAI FAN NOTES: 2. PROVIDE BACK DRAFT DAMPER ®. MOTOR STARTERS, DISCONNECTS (IF NOT FACTORY PROVIDED) AND ALL EQUIPMENT 3. LOCATE BACK DRAFT DAMPER AT DISCHARGE NORMAL POWER AND EMERGENCY POWER WIRING BY ELEC. CONTRACTOR 4. PROVIDE FACTORY MOUNTED DISCONNECT SWITCH AND INTEGRAL THERMAL OVERLOAD PROTECTION, b. ALL CONTINUOUS -DUTY MOTORS SHALL BE PROVIDED WITH OVERLOAD PROTECTION COORDINATE WITH ELECTRICAL CONTRACTOR PRIOR TO ANY PURCHASING. ACCORDING TO NATIONAL ELECTRICAL CODE PAR. 430-32. 5. PROVIDE BIRD SCREEN 6. SUPPORT FROM STRUCTURE COMPLETE WITH VIBRATION ISOLATORS C. FIELD ADJUST OPENINGS WITH STRUCTURE. 7. PROVIDE WEATHERHOOD DRAIN AND CORROSION COATING. d. ALL OUTDOOR EQUIPMENT SHALL COMPLY WITH LOCAL ZONING NOISE 8. PROVIDE WITH MOTORIZE DAMPER. ORDINANCE OR NOT EXCEED A NOISE LEVEL OF 65dB AS MEASURED 9. PROVIDE MOTOR SIDE GUARD RADIALLY 30 FT. FROM THE EQUIPMENT IN ALL DIRECTIONS. 10. PROVIDE SPARK RESISTANCE CONSTRUCTION FAN e. COORDINATE WITH ELECTRICAL CONTRACTOR BEFORE BIDDING OR ORDERING ANY EQUIPMENT. f. SEE PROJECT PLANS AND SPECIFICATIONS FOR OTHER FIELD SUPPLIED ITEMS AND ADDITIONAL INFORMATION. g. ALL FANS ON ROOF SHALL BE PAINTED AS PER ARCHITECTURAL SPECS. 16. ALL BRANCH TAKE -OFFS TO BE PROVIDED W/ MANUAL VOLUME DAMPERS. PROVIDE RADIUS ELBOWS WHERE FEASIBLE, SQUARE ELBOWS AND TEE'S SHALL BE FURNISHED W/SINGLE FOIL TURNING VANES. PROVIDE MANUAL VOLUME DAMPERS WITH EXTRACTOR AT ALL FLEX TAKE -OFFS. PROVIDE REMOTE, CABLE OPERATED VOLUME DAMPERS IN INACCESIBLE AND HARD CEILING AREAS, 'YOUNG REGULATOR" OR EQUAL 17. PROVIDE NEW FILTERS FOR ALL AIR CONDITIONING EQUIPMENT BEFORE START-UP, REPLACE PRIOR TO FINAL ACCEPTANCE BY OWNER. 18. PROVIDE SMOKE DETECTORS WITH SERVICE ACCESS DOORS IN ALL SUPPLY AIR DUCTS FOR FANS AND AHU'S SERVING A COMMON PLENUM OF 2000 CFM OR ABOVE. FOR SMOKE DETECTORS NOT VISIBLE, IN CONCEALED SPACES, PROVIDE REMOTE ANNUNCIATION/TEST STATION AS REQUIRED BY AUTHORITY HAVING JURISDICTION, COORDINATE PRIOR TO INSTALLATION. DETECTORS MALL BE BY ONE MANUFACTURER, COORDINATE VOLTAGE ETC. WITH ELECTRICAL CONTRACTOR AND FIRE ALARM SYSTEM BEFORE ORDERING. UPON DETECTION, SMOKE DETECTORS SHUT DOWN ASSOCIATED AIR MOVING EQUIPMENT AND ALL AIR MOVING EQUIPMENT SERVING THAT COMMON PLENUM. 19. PROVIDE TYPE "B' DYNAMIC FIRE DAMPERS WITH SERVICE ACCESS DOORS IN AEI. DUCTS AND OPENINGS PENETRATING FIRE RATED WALLS, MECHANICAL AND ELECTRICAL EQUIPMENT ROOMS, TENANT SEPARATION, PARTITIONS. FLOOR OR ROOF SLABS AND AT OUTSIDE AIR INTAKES AS REQUIRED. PROVIDE RADIATION DAMPERS IN RATED CEILINGS FOR ALL CEIUNG OPENINGS, CEILING FANS, DIFFUSERS OR GRILLES RATED FOR USE IN THE CEIUNG ASSEMBLY. PROVIDE LOW -LEAKAGE CLASS DAMPERS FOR ALL SITUATIONS WHERE THE AIRFLOW CFM HAS TO BE CONTROLLED. VERIFY AND REPLACE AS REQUIRED FOR EXISTING SYSTEMS. 20. HVAC CONTRACTOR SHALL PROVIDE A T & B REPORT PER F.B.C. 2017. CH. C40B.2.2 (THE T & B REPORT SHALL BE INDEPENDENT FOR SYSTEMS OVER 15 TONS) FOR ALL MECHANICAL EQUIPMENT, AIR DEVICES, DAMPERS, AHU'S AND FANS. THE TEST AND BALANCE REPORT SHALL BE IN ACCORDANCE WITH THE AIR BALANCE COUNCIL STANDARDS AND SHALL INCLUDE AIR QUANTITIES FOR ALL SUPPLY GRILLES, RE11JRN GRILLES AND EXHAUST GRILLES AND THE LEAVING AND ENTERING AIR TEMPERATURE (T=) FROM SUPPLY GRILLES AND EVAPORATORS. FOR (EXISTING) SMOKE EVACUATION SYSTEMS HVAC CONTRACTOR SHALL PROVIDE: A T & B REPORT PRIOR TO ANY NEW WORK, PROVING THAT THE SMOKE EVACUATION SYSTEM PERFORMS PER ORIGINAL DESIGN DOCUMENTS AND IS COMPUANT WITH LOCAL CODE REQUIREMENTS. 21. RUN INSULATED FIRE RATED CONDENSATE DRAINS AS REQUIRED. 22. ALL INSULATION WILL HAVE FIRE/SMOKE RATING LESS THAN 25/50. 23. MECHANICAL EQUIPMENT ON ROOF OR ELEVATED STRUCTURES SHALL COMPLY WITH FBC 2017 PAR. 306.5 IF INSTALLED HIGHER THAN 16 FEET A.F.F. MECHANICAL EQUIPMENT INSTALLED IN ATTICS SHALL MEET THE REQUIREMENTS OF FBC-ENERGY 2017 PAR. C403.2.7.6 IF THE EQUIPMENT CAN NOT BE SERVICED/REMOVED THROUGH REQUIRED OPENING. MECHANICAL EQUIPMENT SHALL BE PROTECTED WITH MECHANICAL BARRIERS IF EXPOSED TO MECH. DAMAGE. ALL EQUIPMENT SHALL BE INSTALLED ON 6" CONCRETE PAD AT GRADE LEVEL . NOTE: AIR HANDUNG UNITS ARE NOT ALLOWED IN COMMERCIAL ATTICS. fifloalm ALL WIND LOAD AND OTHER COMPLIANCE CALCULATIONS AND/OR INSTALLATION DETAILS FOR ROOF MOUNTED EQUIPMENT AS REQUIRED BY FBC 2017, SEC. 1509, 1522 AIND CHAPTER 16, SHALL BE PROVIDED BY STRUCTURAL ENGINEER/ARCHITECT. 24. PROVIDE A MIN. OF 36' CLEARANCE IN FRONT OF ALL 120-208 VOLT PANELS AIND MIN. 42" CLEARANCE IN FRONT OF ANY 240-480 VOLT PANEL PROVIDE ADEQUATE SIDE CLEARANCE PER NEC. 25. MECHANICAL PLANS IN GENERAL, ARE DIAGRAMMATIC IN NATURE, AND ARE TO BE READ IN CONJUNCTION WITH ARCHITECTURAL, PLUMBING, ELECTRICAL, FIRE SPRINKLER, AND STRUCTURAL PLANS AND SHALL BE CONSIDERED AS ONE SET OF DOCUMENTS. DUCT AND PIPING OFFSETS, BENDS AND TRANSITIONS SHALL BE REQUIRED TO PROVIDE AND INSTALL A COMPLETE FUNCTIONAL SYSTEM AND SHALL BE PROVIDED BY THE CONTRACTOR AT NO ADDITIONAL COST TO THE OWNER. CHANGES IN DUCTWORK SIZE AND ROUTE WILL BE REQUIRED TO AVOID STRUCTURAL, PLUMBING, FIRE SPRINKLER AND ARCHITECTURAL BUILDING FEATURES. DUCTWORK CHANGES MAY BE MADE BY CONTRACTOR USING EQUIVALENT SIZED DUCT. CONTACT ENGINEER IF DUCT AREA WILL NOT FIT. 26. THE CONTRACTOR SHALL VERIFY EXISTING CONDITIONS PRIOR TO BIDDING, ORDERING. FABRICATION OR INSTALLATION OF MATERIALS OR EQUIPMENT, IN ORDER TO PROVIDE A FULLY INTEGRATED MECHANICAL AND CONTROLS SYSTEMS WITH THE EXISTING ONES. ANY DISCREPANCY BETWEEN EXISTING CONDITIONS AND PLANS, OR ADDITIONAL CLARIFICATION REQ'D SHALL BE BROUGHT TO THE ATTENTION OF ENGINEER PRIOR TO FINAL BIDDING AND WORK. 27. NO COMBUSTIBLE MATERIALS ARE ALLOWED IN RETURN AIR PLENUMS OR ABOVE CEILINGS USED AS RETURN AIR PLENUM. IF SPACE WITH RETURN AIR PLENUM HAS ANY DECK TO DECK PARTITIONS, AIR TRANSFER DUCTS MUST BE INSTALLED. WHEN CPVC PIPING IS USED FOR FIRE SPRINKLER SYSTEMS, THE R/A GRILLES LAYOUT SHALL BE (FIELD) COORDINATED WITH SUCH PIPING SO THAT NO PORTION OF THE GRILLES WILL BE DIRECTLY BELOW THE CPVC PIPING. 28. CONDENSATE DRAIN PIPING TO BE AS SPECIFIED PER PLUMBING PLANS, IF NOT SPECIFIED TO BE TYPE "L" COPPER OR PVC WHERE ALLOWED BY CODE WITH 1/2' ARMAFLEX INSULATION. PROVIDE APPROVED WATER LEVEL DETECTOR OR FLOAT SWITCH TO AUTOMATICALLY SHUT DOWN THE AIR COND. UNIT, AS A SECONDARY DRAIN SYSTEM TO COMPLY WITH FMC 20117, SEC. 307 SUPPLY CONDENSATE PUMP WHERE NECESSARY AS IMPOSED BY FIELD CONDITIONS OR INSTALLATION CHANGES AND PIPE TO CONDENSATE DRAIN PER PLUMBING PLANS. 29. MANUFACTURER'S WARRANTY: CONTRACTOR SHALL PROVIDE WARRANTY FOR A PERIOD OF (1) ONE YEAR AFTER BUILDING C.O. FOR ALL MECHANICAL SYSTEMS, DUCTWORK, CONTROLS ACCESSORIES AND ALL OTHER EQUIPMENT, PARTS AND LABOR UNDER THESE DRAWINGS AND AND SPECIFICATIONS. CONTRACTOR SHALL PROVIDE WARRANTY FOR COMPRESSORS FOR (5) FIVE YEARS. ANY REPAIRS REQUIRING SYSTEM SHUTDOWN WILL BE DONE DURING NON -OPERATIONAL PERIODS OR AS AGREED WITH OWNER. 30. ON PROJECT SPECIFIED WITH EQUIPMENT UTIUZING HOT GAS REHEAT AND/OR DEHUMIDIFICATION; CONTRACTOR SHALL PROVIDE FACTORY STARTUP OF EQUIPMENT WITHIN THEIR BID. STARTUP REPORT DOCUMENT TO BE PROVIDED TO ENGINEER FOR REVIEW. I O1 COORDINATE FINAL LOCATION IN FIELD WITH EXISTING CONDITIONS. O1OX10 DUCT CHASE UP' TO FLOOR ABOVE. OFUTURE 1.5 TON MINI -SPLIT UNITS. 0 r UP TO ROOF SUPPLY AIR CaLLE SCHEDULE TAG MANUR & MODEL FACE SIZE NECK SIZE MATERIAL FRAME FINISH DAMPER THROW NC RANGE NOTES A METALMRE PHENOMENdATOR 24X24 SEE SCH. ALUM. NOTE #3 OFF WHITE OBD 4-WAY MAX. NCI SEE SOH. 1-5 C TITUS/ FL-10 LINEAR SEE SON. AUIM. NOTE /3 OFF WHITE OBO 4-WAY MAX. 25 SEE SCH. 1-5 ®1 PHENOMENATOR 12X12 I SEE SCH. I ALUM. NOTE #3 OFF WHITE OBD 4-WAY MAX. 30 SEE SCH. 1-5 (*) EQUIVALENT MANUFACTURER: METALAIRE, PRICE, CARNES, T & B. NAILOR 1. PROVIDE SPIN -IN COLLAR AT TRUNK TO FLEX DUCT CONNECTION. 2. PROVIDE TYPICAL 4-WAY DIFFUSION, 2-WAY OR 3-WAY ONLY WHERE INDICATED ON PLAN �� BCME 3. REFER TO ARCHITECT PLANS FOR CEILING TYPE. 4. CONTRACTOR TO COORDINATE FINAL SELECTION WITH AF041TECT AND OWNER BP 50-125 (FM 5. FLEX DUCT SIZE TO BE SAME AS DIFFUSER NECK SIZE 8/' 130-200 CFM 100" 205-330 CFM CONTRACTOR SHALL VERIFY WITH ARCHITECT AND TENANT/OWNER, 12e' 335-450 CFM PRIOR TO ANY PURCHASING OR INSTALLATION, IF A BOLDING STANDARD HAS TO BE FOLLOWED REGARDING A SPECIFIC MODEL 94M' 45, 5-800 CFM OR MANUFACTURER AND SHALL BRING ANY DISCREPANCY TO THE ATTENTION OF IENGINEER. 191^' 805-700 CFM TV RETURN AIR GFILLE SCHEDULE -� TAG MANUF. & MODEL FACE SIZE NECK SIZE MATERIAL FRAME FINISH DAMPER THROW NC CFM RANGE NOTES AA PHENOMENATOR METALAIRE 24X24 SEE SOH. ALUM. NOTE #1 OFF WHITE - - MAX. 30 SEE SCH. 1-3 CC TITUS/ MLR-39 UNEAR SEE SCH. ALUM. NOTE /1 OFF WHITE - - MAX. 25 SEE SCH. 1-3 BB PHENOTALAIRE MENATad 12x12 SEE SOH. ALUM. NOTE {j1 OFF WHITE _ - MAX. 30 SEE SC.H. 1-3 (0) EQUIVALENT MANUFACTURER: METALAIRE. PRICE, CARNE% T & B. NAILOR CONTRACTOR SHALL VERIFY WITH ARCHITECT AND TENANT OR OWNER, PRIOR TO ANY PURCHASING OR INSTALLATION, AN MGM IF A BUILDING STANDARD HAS TO BE FOLLOWED REGARDING A SPECIFIC MODEL OR MANUFACTURER AND SHALL BRING 1. REFER TO ARCHITECT PLANS FOR CEILING TYPE ANY DISCREPANCY TO THE ATTENTION 01' ENGINEER. 2. FINAL COLOR SELECTION SUBJECT TO ARCHITECT APPROVAL - 3. PROVIDE INSULATION ON THE BACK OF DIFFUSER IF IN N111Clt: em CFM EAWE NWX M CFM RANW UNCONDITIONED FACE - 6X6 0-150 CFM 15x1!i 0-900 CFM 8X8 0-250 CFM 18X18 0-1350 CFM toxlo 0-400 CFM 22x22 0-2000 CFM 12x12 D-600 cFM - IN ISOLATION, SEE SPECS M6.1 HIGH CONCRETE PAD MECHANICAL PLAN- ? --ALE; -WATERPROOF SEAMS AND JOINTS (TYP) WATERPROOF CAULK - ALL AROUND (TYP.) GALV. METAL DUCTWORK WITH MIN. R-8 DOUBLE WALL DUCT EQUAL TO "K-27" 1-1/2"x1-1/2x1/4"TH ANGLE IRON SUPPORT ALL AROUND DUCT. TYP. SHEET METAL SCREWS -J OR TAPCONS AS APPLICABLE OUTDOOR GALV. METAL DUCTWORK WITH MIN, R-6 EXTERIOR INSULATION :1 I __---FLANGE--_.---- DUCT THROUGH WAIL (SEE ARCH.) WALL (SEE ARCH.) INDOOR FUTURE MEZZANINE AA26003774 517 SW nALULL AVrnUr POPT SAIM LUCIr rL. 54955 '772-800-5700 www1blar(hiteaure.(om �C S Mc r 44r d 14248 �J �L LL- >_ CAL O 0 lam_ OJ1 LLJ y J OL LLJ II J %/'N t- 00 OL 0 F- v O II l (�m a. DO(MI11T DATA: DATE: PIVISIOM: f1� YOUP PROWSS SUbAIT DAR Srl[[T TITLE: MECHANICAL PLAN SM(T MAW: mml SHOCK ARRESTOR SCHEMILE P.D.I. DESIGNATION MANUF. & MODEL FIXTURE UNITS CONNECTION A SIOUX CHIEF 652-A 1-11 1/2" B SIOUX CHIEF 653-B 12-32 3/4- C SIOUX CHIEF 654-C 33-60 1. SIOUX CHIEF SHOCK ARRESTORS APPROVED FOR INSTALLATION WITH NO ACCESS DOOR REQUIRED. CONFORMS TO ANSI/ASSE 1010 STANDARDS. SLOPE OF ±2M. UHANA99 PIPE SIZE (inches) MINIMUM SLOPE (Inch per foot) 2-1/2 or less 1/4 3 to 1/8 8 or larger 1/16 TABLE 704.1 OF THE FLORIDA PLUMBING CODE 2017 CONDENSATE DRAIN PIPE SIZING HVAC EQUIPMENT CAPACITY MINIMUM CONDENSATE PIPE DIAMETER UP TO 20 TONS OF REFRIGERATION 1" OVER 21 TONS TO 40 TONS OF REFRIGERATION 1-1/4- OVER 41 TONS TO 60 TONS OF REFRIGERATION 1-1/2- OVER 61 TONS TO 100 TONS OF REFRIGERATION 2- OVER 101 TONS TO 250 TONS OF REFRIGERATION 3- OVER 251 TONS & LARGER OF REFRIGERATION 4" PLUMBING FIXTURE SCHEDULE F DICAP LAVATORY, AMERICAN STANDARD, LUCERNE WALL HUNG LAVATORY MODEL #0356.028. E, WITH T&S BRASS FAUCET BS-2701-VF05. CONTRACTOR TO SUPPLY CONCEALED ARM SUPPOR PORT CARRIER FOR MOUNTING OF LAV. WADE MODEL If 520-M36. SUPPLY PLUMBEREX MODEL /4333 INSULATION KIT. MUST MEET A.D.A. CODE. WC WATER CLOSET, AMERICAN STANDARD 2333.100 FLOOR MOUNTED, WHITE CENTOCO SEAT # 50OCC, OPEN FRONT WITH COVER. A.D.A EL 1.28 ELONGATED OR EQUAL HANDICAP WATER CLOSET, AMERICAN STANDARD #215AA.004 FLOOR MOUNTED, WHITE, CENTOCO SEAT HWC #500CC, OPEN FRONT WITH COVER. A.D.A EL 1.28 ELONGATED 18" HIGH OR EQUAL HDF ELKAY LZS8WSLP ENHANCED EZH2O BOTTLE FILLING STATIONA ND SINGLE ADA COOLER, FILTERED, 8 GPH, LIGHT GRAY FIAT MSB MODEL # 2424 MOLDED TERRAZZO BASIN WITH DRAIN BODY AND STRAINER. MOP FIAT SERVICE SINK FAUCET MODEL #530-AA, WITH FIAT 832-AA HOSE AND HOSE BRACKET SK DISCHARGE; PAIL HOOK AND TOP BRACE; VACUUM BREAKER, FIAT #889-CC MOP HANGER AND BP !SPLASH CATCHER ALL GUARD. RECIRC TACO RECIRC. PUMP. MODEL 111 BRONZE CASTING , 115V, 1/8 HP, 2.0 AMP WITH PUMPLWA-TnER TIMER AQUSTAT. EWH HEATER SHALL BE 30 GAL ELECTRIC 208V, 1 PHASE, 4.5 KW. HINVAR TALL MODEL ETT-OW-KD. GENERAL NO ,5 (1) - FIXTURES SHALL BE AS SHOWN OR EQUAL - ALL FIXTURES SHALL COMPLY WITH TABLE 604.4 OF FBC 2017 ((2) 3)- ALL FIXTURE TRIM PACKAGES INCLUDING BUT NOT LIMITED TO TRAP, ANGLE STOP, FLUSH VALVE" SUPPLY TUBES, AND CLEANOUT COVER PLATES SHALL BE OF THE SAME FINISH AS THE ABOVE SPECIFIED FAUCET AND PER ARCHITECTURAL FINISH SCHEDULE. (4) - ALLFIXTURES SHALL BE ROUGHED IN PER MANUFACTURER CUT SHEET TO MAINTAIN UNIFORMITY. PROVIDE TEST TEE WITH SCREWED COUNTER- SUNK ABS PLASTIC PLUG: TAPERED -THREAD WITH TFE JOINT COMPOUND. - MERE CLEANOUT TEE IS CONCEALED IN A CHASE OR PARTITION, PROVIDE A ROUND 18 GAUGE STAINLESS STEEL COVER WITH BEVELED EDGES AND FLATHEAD MACHINE SCREW. . d CONCRETE CC_ FLOOR SLAB COLUMN OR PARTITION AS SHOWN ON FLOOR PLAN CLEANOUT FACE SHALL BE WITHIN 4" OF WALL SURFACE. PROVIDE PIPE EXTENSION IF REQUIRED. NOTE: PROVIDE WCO WHERE SHOWN ON PLAN, AND ON SANITARY WASTE BRANCHES NOT SERVED WITH A (FLOOR CLEANOUT: LOCATE ABOVE FIXTURE FLOOD RIM WITHIN 4' OF FLOOR. CONSULT LOCAL CODES FOR 07HER WCO REQUIREMENTS. WALL CLEANOUT DETAIL NOT TO SCALE PROVIDE 3/8" DIAMETER THREADED ROD WITH WASHERS AND DOUBLE NUTS AT EACH END. ROUTE ROD FROM CHANNEL BELOW WATER HEATER UP TO FASTENERS ABOVE. (TYPICAL OF 4) ___7 3/6" HILTY INSERT HDI-3/8". (TYPICAL OF 4) BAR JOIST STRUCTURAL SUPPORT SYSTEM.--a� COLD WATER SUPPLY TO WATER HEATER HEAT TRAP (OMIT IF HEAT TRAP IS AN INTEGRAL PART OF HEATER). HOT WATER TO FIXTURES AS SHOWN ON PLANS. PROVIDE FULL PORT BALL SHUT-OFF VALVES. PROVIDE PIPE UNIONS, DIELECTRIC IF REQUIRED FOR DISSIMILAR METALS. DRAIN VALVE BY HEATER MAUFACT. THERMOSTAT AND PRESSURE REGU- LATOR FURNISHED WITH WATER HEATER.- 3/4' PLYWOOD BELOW WATER HEATER DRAIN PAN AS PLATFORM. 2" DEEP SAFEPAN. PROVIDE A DRAIN / PAN, RUN OVERFLOW UNE TO EXTERIOR OF BUILDING AT 6" ABOVE GRADE OR NEAREST APPROVED WATER HEATER - MAXIMUM INDIRECT WASTE. OF 30 GALLON CAPACITY. PIPING ARRANGEMENT SHOWN IS SCHEMATIC:. ADJUST TO SUIT FIELD CONDITIONS. REFER TO ISOMETRIC RISER FOR PIPE SIZES. SET HEATER THERMOSTAT AT 120' F. PROVIDE MIXING VALVES AS REQUIRED AT LAVATORIES TO COMPLY WITH FBC ENERGY 504.3. PUMP HOT WATER RECIRCULATION 7UNE PROVIDE A 210T TEMPERATURE AND 150 PSI PRESSURE RELIEF VALVE WITH TEST LEVER SIZED WITH AGA/CGA TEMPERATURE STEAM RATING 10X OVER HEATING INPUT. PROVIDE A HARD COPPER RELIEF VALVE DISCHARGE LINE FULL SIZE OF VALVE OUTLET RUN TO INDIRECT WASTE IN SAME ROOM OR TO OUTSIDE BUILDING 6" ABOVE GRADE WITH A VISIBLE AIR GAP IN SAME ROOM PER FLORIDA BUILDING CODE 2017 SEC. 504.6.1 PROVIDE 2" CHANNELS WITH MINIMUM 2 COATS OF RUSTPROOF PRIMER SPANNONG BETWEEN THREADED RODS TO SUPPORT WATER HEATER SAFEPAN. 1. THE CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, AND EQUIPMENT ESSARY FOR THE INSTALLATION OF A COMPLETE SCOPE OF WORK. ALL WORKMANSHIP AND g, RIALS SHALL BE IN STRICT ACCORDANCE WITH THE FLORIDA BUILDING CODE 6TH EDITION (2017'. PLUMBING, APPLICABLE LOCAL CODES, RULES, AND ORDINANCES. 2. PLUMBING CONTRACTOR SHALL VISIT THE JOB SITE AND THOROUGHLY FAM RIZE HIMSELF WITH ALL EXISTING CONDITIONS. 3. ALL MATERIALS SHALL BE NEW AND OF GOOD QUALITY. 4. ALL WORK SHALL BE PERFORMED BY A LICENSED PLUMBING CONTRACTOR; FIRST CLASS WORKMANLIKE MANNER. THE COMPLETED SYSTEM SHALL BE FULLY -OPERA XL ALL EXCAVATION AND BACKFILL AS REQUIRED FOR THIS PHASE OF CONSTRUCTION SHALL BE ART OF THIS CONTRACT. 5. REQUIRED INSURANCE SHALL BE PROVIDED BY THE PLUMBING CONTRACTOR F PROTECTION AGAINST PUBLIC LIABILITY AND PROPERTY DAMAGE FOR THE DURATION OF TI WORK. 6. PLUMBING CONTRACTOR SHALL SECURE AND PAY FOR ALL PERMITS, FEES, IN ECTIONS AND TESTS. PLUMBING CONTRACTOR SHALL OBTAIN PERMIT AND APPROVED SUBMITTALS P )R TO BEGINNING WORK OR ORDERING EQUIPMENT. PLUMBING CONTRACTOR MUST BE PRESENT 7R ALL INSPECTIONS OF HIS WORK BY REGULATORY AUTHORITIES. 7. CONTRACTOR SHALL SUBMIT TO ARCHITECT/ENGINEER, FOR REVIEW & APPROVk FIVE (5) SETS OF MANUFACTURER'S CUT SHEETS FOR EACH FIXTURE, PIPING/FITTING MATERIAL At, rQUIPMENT ITEM WITH ASSOCIATED CONTROLS, THAT ARE INCLUDED IN THE CONTRACT. 8. DRAWINGS ARE DIAGRAMMATIC. DO NOT SCALE FOR THE EXACT LOCATION OF F' :S, PIPING, EQUIPMENT, ETC. 9. ALL WORK SHALL BE COORDINATED WITH OTHER TRADES TO AVOID INTERFERE:NCU I THE PROGRESS OF CONSTRUCTION. REPORT ANY DISCREPANCY TO ARCHITECT/ENIGINI RIOR TO BEGINNING CONSTRUCTION. 10. VERIFY LOCATION, SIZE, DIRECTION OF FLOW AND INVERT ELEVATIONS OF ALL EXI UTILITIES PRIOR TO BEGINNING OF CONSTRUCTION. ADVISE ARCHITECT/ENGINEER OR ANY I ?ANCIES. 11. WATER DISTRIBUTION PIPING ABOVE AND BELOW GROUND SHALL BE TYPE -L" COP ALTERNATE PIPING & FITTING MATERIALS MAY BE USED IN ACCORDANCE WITH FLORIDA BIUILDI )DE 6TH EDITION (2017) - PLUMBING, TABLES 605.3, 605.4 & 605.5, WHEN APPROVED BY AEER OF RECORD AND LOCAL AUTHORITY HAVING JURISDICTION. PROVIDE ALTERNATE FOR PIPING & FITTINGS EQUAL TO LUBRIZOL CORZAN OR FLOW -GUARD GOLD. PROVIDE ALTERNr OR PEX TYPE 'A' PIPING & FITTINGS EQUAL TO UPONOR. ALTERNATES ARE PERTINENT FOR' WAl ERVICES KNOWN OR DETERMINED TO HAVE ACIDIC CHARACTERISTICS OR OTHER PARTICULAR :;UMSTANCES AS DEEMED APPROPRIATE BY DIRECTIVE FROM THE OWNER. CONTRACTOR SHALL I ORM A WATER TEST TO DETERMINE WATER CHEMISTRY PRIOR TO ANY WORK OR PIPING INSTALLA7 AND SHALL SUBMIT TEST RESULTS TO THE ARCHITECT/ENGINEER FOR REVIEW AND APPROVAL 9NFECTION OF POTABLE WATER SYSTEM SHALL COMPLY WITH FLORIDA BUILDING CODE 6TH ED17101 '017) - PLUMBING, SECTION 610. ALL WATER PIPING & FITTINGS SHALL BE OF DOk' ST1C I UFACTURE; SPECIFICALLY IN THE UNITED STATES OF AMERICA. 12. SOIL, WASTE, VENT, AND RAINWATER (DWV) PIPING & FITTINGS SHALL BE CAST IF PVC, WHERE CODE ALLOWS. PVC MAY NOT BE USED THRU RATED ASSEMBLIES OR IN PLENUM PIPING SHALL BE SOLID -CORE ONLY, FOAM -CORE PIPING SHALL NOT BE ACCEPTED. CAE N PIPING & FITTINGS SHALL BEAR THE CISPI-301 MARK. ALL DWV PIPING & FITTINGS SHALL B. DOMESTIC MANUFACTURE; SPECIFICALLY IN THE UNITED STATES OF AMERICA. 13. ALL FIXTURES MUST BE PROVIDED WITH READILY ACCESSIBLE ANGLE STOPS AND APF PRIATELY MARKED ACCESS PANELS (WHERE REQUIRED). COORDINATE LOCATIONS WITH :`_NEr'1k 'ONTRACTOR PRIOR TO INSTALLATION. 14. PROVIDE APPROVED WATER HAMMER ARRESTORS FOR ALL (GROUP) PLUMBING FIXT SIZED & LOCATED PER MANUFACTURER'S INSTALLATION INSTRUCTIONS & PDI-WH2O1. 15. PROVIDE DIELECTRIC COUPLINGS OR FLANGES BETWEEN ALL DISSIMILAR METALS IN P: G AND EQUIPMENT CONNECTIONS. 16. ISOLATE COPPER PIPING FROM METALLIC HANGERS OR SUPPORTS WITH ISOLATOR P 2 NON-CONDUCTIVE MATERIAL, 17. ALL FIRE RATED FLOOR AND WALL PENETRATIONS SHALL BE PROPERLY PROTECTED F FIRE, SMOKE AND WATER PENETRATION BY FILLING ANNULAR SPACE BETWEEN PIPING AND VES WITH INTUMESCENT CAULK, TO ACHIEVE THE SAME RATING AS WALLS OR FLOORS, AS PAR THE PLUMBING CONTRACTOR'S WORK, 18. PLUMBING CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORKMANSHIP FREE F DEFECTS FOR A PERIOD OF NOT LESS THAN ONE (1) YEAR FROM DATE OF ACCEPTANCE BY OV CORRECTION OF ANY DEFECTS SHALL BE COMPLETED WITHOUT ADDITIONAL CHARGE A ALL INCLUDE REPLACEMENT OR REPAIR OF ANY OTHER PHASE OF THE INSTALLATION Wilt. Y HAVE BEEN DAMAGED. 19. PROVIDE ACCESS PANELS FOR ALL CONCEALED VALVES. ACCESS PANELS IN RATED V SHALL MAINTAIN THE SAME RATING AND SHALL MATCH THE FINISH OF THE WALL IN WHICH 11 ISTALLED. 20. PROVIDE COMBINATION CLEANOUT PLUG AND COVER PLATE OR ACCESS PANEL, FOR ALL CLEANOUTS. FINISH TO MATCH NEARBY FIXTURE TRIM. 21. NO COMBUSTIBLE MATERIAL SHALL BE INSTALLED IN MECHANICAL ROOMS NOR IN C SPACES WHERE USED AS RETURN AIR PLENUMS. 22. NO WATER, SANITARY OR DRAINAGE PIPING SHALL BE INSTALLED IN ELECTRICAL OF EVATOR EQUIPMENT ROOMS. 23. ALL CONTROL VALVES SHALL BE TAGGED AND MARKED. A REPRODUCIBLE DIAGRr 1CATING ALL VALVES SHALL BE FURNISHED FOR OWNER/OPERATOR. 24. CONDENSATE DRAIN PIPING SHALL BE TYPE -L- COPPER NTH ARMAFLEX INSULATION AND A VAPOR -BARRIER JACKET PER FLORIDA BUILDING CODE 6TH EDITION (2017) - ENERGY CONSERVATION, TABLE C403.2.8. PVC WITHOUT INSULATION IS ACCEPTABLE FOR RISERS AND BELOW GRADE PIPING. WHEN USED IN A RETURN AIR PLENUM, PVC PIPING WITH INSULATION IS ACCEPTABLE IN LOCATIONS WHERE ALLOWED BY LOCAL CODES. CONDENSATE PIPING SHALL NOT DRAIN ONTO THE ROOFING SYSTEM NOR ANY OF ITS COMPONENTS. CONDENSATE PIPING ARRANGEMENT IS EXEMPT FROM MINIMUM EQUIPMENT CLEARANCE REQUIREMENTS PER FLORIDA BUILDING CODE 6TH EDITION (2017), SECTION 1522.3.5. ALL HORIZONTAL RAINWATER PIPING RUN ABOVE FINISHED FLOOR THAT RECEIVES CONDENSATE DISCHARGE SHALL BE INSULATED WITH ARMAFLEX AND A VAPOR -BARRIER JACKET. 25. HOT WATER PIPING INSULATION SHALL BE PROVIDED IN ACCORDANCE WITH FLORIDA BUILDING CODE 6TH EDITION (2017) - PLUMBING, TABLE 607.5 & FLORIDA BUILDING CODE 6714 EDITION (2017) - ENERGY CONSERVATION, TABLE C403.2.8. CONTRACTOR SHALL USE ARMAFLEX OR EQUAL WHERE APPLICABLE. WHERE DOMESTIC WATER TEMPERATURES CAN CAUSE SWEATING, ALL COLD WATER PIPING SHALL BE INSULATED WITH ARMAFLEX INSULATION AND A VAPOR -BARRIER JACKET, PER FLORIDA BUILDING CODE 6TH EDITION (2017) - ENERGY CONSERVATION, TABLE: C403.2.8. 26. AIR ADMITTANCE VALVES MAY BE USED AS AN ALTERNATE TO VENT PIPING THRU ROOF WHERE pACCCEEPPTTEgD� BY THE { LOCAL F AUTHORITY �HEA�VING JU�RIISDIIC�TIIOgNp.�� IN�SSTTAULLLATTION METHODS SHALL BE IN 27.PROVIDE AN STOPS ONAALL WATER %WUNIS TO FIXTURES(FOR' DIMDUAL SHUT-OFF. 28• STUDOR MINI/MAXI AIR ADMITTANCE VALVES MAY BE USED AS AN ALTERNATE TO VENT PIPING THRU ROOF WHERE ACCEPTABLE BY THE PLUMBING OFFICIAL AND LOCAL CODES. INSTALLATION SHALL BE AS PER MANUFACTURER'S RECOMMENDATIONS„ 29. ALL HORIZONTAL RAINWATER PIPING THE RECEIVES CONDENSATE DISCHARGE FROM AIR CONDITIONING EQUIPMENT SHALL BE INSULATED WITH 1" THK. ARMAFLEX. 30. PLUMBING PLANS IN GENERAL, ARE DIAGRAMMATIC IN NATURE, AND ARE TO BE READ IN CONJUNCTION WITH ARCHITECTURAL, MECHANICAL, ELECTRICAL, FIRE SPRINKLER, STRUCTURAL, AND CIVIL PLANS AND SHALL BE CONSIDERED AS ONE SET OF DOCUMENTS. PIPING MODIFICATIONS SUCH AS OFFSETS, BENDS, TRANSITIONS, AND SIZES SHALL BE REQUIRED TO PROVIDE AND INSTALL A COMPLETE FUNCTIONAL SYSTEM AND SHALL BE PROVIDED BY THE CONTRACTOR AT NO ADDITIONAL COST TO THE OWNER. CHANGES IN PIPE SIZES AND ROUTING SHALL BE REQUIRED BY THE CONTRACTOR TO AVOID CONFLICTS AND TO ADAPT TO EXISTING FIELD CONDITIONS PROVIDED THAT INSTALLATION MEETS ALL APPLICABLE CODES. 31. SUPPLY TRAP PRIMER FOR ALL FLOOR DRAINS, FLOOR SINKS, HUB DRAINS, ETC. SHOWN ON PLANS. 32. CONTRACTOR TO FIELD VERIFY ALL SUPPLY PRESSURE REQUIREMENTS AND LIMITATIONS. PROVIDE PRESSURE REDUCING VALVE IF REQUIRED. O1 EXISTING 3' SANITARY LINE, FIELD VERITY EXACT LOCATION, INVERT, AND CONNECTION POINT PRIOR TO ROUGH IN. O3" SANITARY RISER TO FLOOR ABOVE, PROVIDE ACCESSIBLE CLEANOUT AT BASE OF RISER. O3/4" DOMESTIC WATER LINES TO FLOOR ABOVE, PROVIDE ISOLATION VALVES FOR EACH RXTURE. OEXISTING DOMESTIC WATER CONNECTION; FIELD VERIFY EXACT SIZE, LOCATION AND CONNECTION POINT. 0 e .JIB �I I A + `\+ \ LL riu% izz ezoIle , l l I 1 e DOM. WATER ISOMETRIC N.T.S. ������*L#MBING PLAN SC,A-�E: 1/4" r V-0" f UTURE MEZZANINE AA20003774 517 SW MULL AVEW PORT SAM LUCK rL. 54955 772-800-5700 www1jar(h i te(turexom OF PL0 S. Meg, jd 14248 U �w ti �.J Ei ® ®_ u- nz 0�0 <� 0 ,./'\ u.-.J �L LLJ LL-J ~ Q OG u� 0 0 O LLJ r- , 0_ d DOCU/AE17T DATE:: DATE: REVISIOnS: fly TOUR PROWSS S&AIT DATE SHUT TITLE: PLUMBING PLAN SKEET nUfWP: 95